ENERGY RECOVERY VENTILATOR ERV 60H Part no. 606 (TOP PORTS) Part no. 60 (SIDE PORTS) 5 to 05 CFM (0. in. w.g.) VB0073 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT! Configured with factory built vertical or horizontal ports, the vänee ERV 60H is the most versatile 00-cfm unit available on the market today. Among its exclusive features, this unit is equipped with integrated balancing and backdraft dampers in its exhaust to outside and fresh air supply ports. For a standard installation, there is no need to balance the unit*, thanks also to its twin high-pressure blowers. Its operation can be interlocked with an existing furnace without adding an extra relay. Also, for more convenience, its latches can be relocated on its front (as shown on unit picture). This compact, lightweight, and powerful unit is the ideal choice for small single-family homes, high rise residential building and other limited space applications. *To avoid balancing, the difference between stale air ducts total length and fresh air ducts total length must not exceed 50 ft. Versatile horizontal or vertical port configuration Removable terminal block to ease auxiliary wall control connections Integrated pressure taps, if balancing required by building code ENERGY STAR qualified REPAIRS AND MAINTENANCE All parts of the vänee ERV 60H that could need maintenance can be removed in less than 5 minutes, allowing direct access for easy repairs. The PSC motors are permanently lubricated. Finally, the removable electrical drawer with pull-out PCB assembly allows easy access for maintenance of major sub-components. WARRANTY The vänee ERV 60H is protected by a 2-year warranty on parts only. The energy recovery core is covered by a 5-year warranty, with the original proof of purchase. Available at: Controls This unit is very simple to operate. Once it is installed, press on its push button, located on on the bottom of the unit, to activate it. Press once for low speed, once again for high speed, and once more to stop it. The following main controls are available: - Platinum programmable digital control with SMART mode no. 060 - Deco-Touch digital control no. 0295 - Bronze no. 0250 - Lite-Touch Bronze no. 0270 - Simple-Touch Bronze no. 0290 The following optional auxiliary controls can also be added: - 20-min. lighted push button no. 8060-60-min. mechanical timer no. 0090 For more details about controls, refer to their specification sheet on vanee.ca. Options Complete line of registers and diffusers Electric duct heater Dual exterior hood kit (including the Tandem transition), part no. 690 Homeshield Defrosting System The vänee ERV 60H uses a unique defrosting method. No negative pressure is created by air exhausted to the outside, as the air is recirculated into the house, helping to prevent any backdraft. STALE AIR FROM FILTERED AIR TO VF0037 Energy Recovery Core Dimensions: 9/8 x 37/6 x 6 7/8 (8,6 cm x 3, cm x 7,3 cm) Exchange surface: 56 ft.2 (5.2 m2) Weight: 9.25 lb. (,2 kg) Material: Polymerized paper Type: Crossflow and counterflow core Warranty: 5 years Requirements and Standards OUTSIDE DEFROST CYCLE (IN MINUTES) Complies with the UL 82 requirements regulating the installation of Energy Recovery Ventilators Complies with the CSA C22.2 no. 3 Standard applicable to ventilators Complies with CSA C requirements regulating the installation of Energy Recovery Ventilators Technical data was obtained from published results of tests relating to CSA C39 Standards HVI certified and ENERGY STAR qualified oc THAN -5 of THAN 23 DEFROST/ OPERATION NO DEFROST -5 TO -27 23 TO -7 9/28-27 -7 0/22
DIMENSIONS: VÄNEE ERV 60H (PORTS ON SIDES) ALL PORTS FIT (02 mm) 27 /6 (688 mm) 22 9/6 (57 mm) 9 3/6 (503 mm) 6 (52 mm) /6 (30 mm) VK0057A SPECIFICATIONS : FRESH AIR TO PORT 2 : EXHAUST AIR FROM PORT VENTILATION PERFORMANCE EXTERNAL STATIC PRESSURE NET GROSS EXHAUST PA IN. W.G. L/S CFM M 3 /H L/S CFM M 3 /H L/S CFM M 3 /H 25 0. 5 5 95 55 7 99 55 7 99 50 0.2 53 2 90 5 5 95 5 93 75 0.3 5 09 85 53 89 52 0 87 00 0. 9 05 78 50 06 80 50 06 80 25 0.5 8 02 73 9 0 77 9 03 75 50 0.6 5 96 63 7 99 68 7 99 68 75 0.7 93 58 5 9 60 5 9 60 200 0.8 2 89 5 3 92 56 2 88 50 225 0.9 0 85 87 8 87 8 250.0 38 8 38 39 89 38 8 38 ENERGY PERFORMANCE NET C F L/S CFM M 3 /H POWER CONSUMED WATTS RECOVERY EFFICIENCY APPARENT EFFECTIVENESS LATENT RECOVERY/ MOISTURE TRANSFER HEATING 0 32 23 9 83 2 67 79 0.6 0 30 6 09 60 65 75 0.55 0 32 0 8 3 72 63 7 0.8-25 -3 23 9 83 58 60 75 0.60-25 -3 30 6 09 7 55 7 0.57 COOLING TOTAL RECOVERY EFFICIENCY 35 95 2 75 2 50 2 (5 mm) 3 : FRESH AIR FROM OUTSIDE PORT : EXHAUST AIR TO OUTSIDE PORT VÄNEE ERV 60H (PORTS ON TOP) 93 6 (503 mm) 6¼ (3 mm) NOTE: All specifications are subject to change without notice. Model: ERV 60H Core filters: 30 ppi washable foam Speed control on unit: Low & high speeds. Part number top ports: 606 8.75 x 6.75 x 0.5 (22,2 cm x 7,2 cm x,3 cm) Other modes available with main and Part number side ports: 60 Housing: Pre-painted steel optional wall controls. Insulation: Expanded polystyrene Energy recovery core: Total assembled weight (including Mounting: Suspension by chains and springs - Heat exchange surface area: 56 ft. 2 (5.2 m 2 ) polymerized paper core): 5 lb. (20. kg) - Type: Crossflow and counterflow Supply and exhaust blower motor: 2 motors - Material: Polymerized paper Oval shaped ports; fit 5 diameter ducts - Protection type: Thermally protected Unit electrical characteristics: - Insulation class: B 20 volts, 60 Hz, ampere, 0 watts VK0058A ALL PORTS FIT 22 9 6 (57 mm) 23¾ (603 mm) : FRESH AIR TO PORT 2 : EXHAUST AIR FROM PORT 3 : FRESH AIR FROM OUTSIDE PORT : EXHAUST AIR TO OUTSIDE PORT (02 mm) 6 (52 mm) 6 (30 mm) 2½ (6 mm) Project: Location: Part Number: Qty.: Submitted by: Date: REMARKS 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 800 567-3855 Fax 800 567-75 www.vanee.ca 3/ PRODUCT SHEET NO. 9053
HEAT RECOVERY VENTILATOR HRV 60H Part no. 602 (TOP PORTS) Part no. 600 (SIDE PORTS) 39 to 98 CFM (0. in. w.g.) VB0072 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT! Configured with factory built vertical or horizontal ports, the vänee HRV 60H is the most versatile 98-cfm unit available on the market today. Among its exclusive features, this unit is equipped with integrated balancing and backdraft dampers in its exhaust to outside and fresh air supply ports. For a standard installation, there is no need to balance the unit*, thanks also to its twin high-pressure blowers. Its operation can be interlocked with an existing furnace without adding an extra relay. Also, for more convenience, its latches can be relocated on its front (as shown on unit picture). This compact, lightweight, and powerful unit is the ideal choice for small single-family homes, high rise residential building and other limited space applications. What s more, it is the only air exchanger of its size that can be upgraded from an HRV to an ERV, simply by changing its core. *To avoid balancing, the difference between stale air ducts total length and fresh air ducts total length must not exceed 50 ft. Versatile horizontal or vertical port configuration Removable terminal block to ease auxiliary wall control connections Integrated pressure taps, if balancing required by building code ENERGY STAR qualified REPAIRS AND MAINTENANCE All parts of the vänee HRV 60H that could need maintenance can be removed in less than 5 minutes, allowing direct access for easy repairs. The PSC motors are permanently lubricated. Finally, the removable electrical drawer with pull-out PCB assembly allows easy access for maintenance of major sub-components. WARRANTY The vänee HRV 60H is protected by a 2-year warranty on parts only. The heat recovery core is covered by a limited lifetime warranty, with the original proof of purchase. Available at: Controls This unit is very simple to operate. Once it is installed, press on its push button, located on on the bottom of the unit, to activate it. Press once for low speed, once again for high speed, and once more to stop it. The following main controls are available: - Platinum programmable digital control with SMART mode no. 060 - Deco-Touch digital control no. 0295 - Bronze no. 0250 - Lite-Touch Bronze no. 0270 - Simple-Touch Bronze no. 0290 The following optional auxiliary controls can also be added: - 20-min. lighted push button no. 8060-60-min. mechanical timer no. 0090 For more details about controls, refer to their specification sheet on vanee.ca. Options Complete line of registers and diffusers Electric duct heater Dual exterior hood kit (including the Tandem transition), part no. 690 Homeshield Defrosting System The vänee HRV 60H uses a unique defrosting method. No negative pressure is created by air exhausted to the outside, as the air is recirculated into the house, helping to prevent any backdraft. STALE AIR FROM FILTERED AIR TO VF0036 Heat Recovery Core Dimensions: 3 x 9 x 6 7/8 (33 cm x 8.3 cm x 7.3 cm) Exchange surface: 55 ft.2 (5. m2) Weight: 3.75 lb. (.7 kg) Material: Polypropylene Type: Cross flow Warranty: Limited lifetime Requirements and standards OUTSIDE DEFROST CYCLE (IN MINUTES) Complies with the UL 82 requirements regulating the installation of Heat Recovery Ventilators Complies with the CSA C22.2 no. 3 Standard applicable to ventilators Complies with CSA C requirements regulating the installation of Heat Recovery Ventilators Technical data was obtained from published results of tests relating to CSA C39 Standards HVI certified and ENERGY STAR qualified oc THAN -5 of THAN 23 DEFROST/ OPERATION NO DEFROST -5 TO -27 23 TO -7 8/25-27 & LESS -7 & LESS 0/22
DIMENSIONS: VÄNEE HRV 60H (PORTS ON SIDES) ALL PORTS FITS (02 mm) 27 /6 (688 mm) 22 9/6 (57 mm) 9 3/6 (503 mm) 6 (52 mm) 3¾ (39 mm) /6 (30 mm) SPECIFICATIONS : FRESH AIR TO PORT 2: EXHAUST AIR FROM PORT VENTILATION PERFORMANCE EXTERNAL STATIC PRESSURE NET GROSS EXHAUST PA IN. W.G. L/S CFM M 3 /H L/S CFM M 3 /H L/S CFM M 3 /H 25 0. 53 9 53 2 90 57 20 20 50 0.2 5 07 8 5 08 8 5 9 75 0.3 8 0 72 8 02 73 52 0 87 00 0. 6 98 67 7 99 68 9 05 78 25 0.5 3 9 55 3 92 56 7 00 70 50 0.6 88 8 2 88 5 5 96 63 75 0.7 39 89 39 83 3 9 55 200 0.8 37 79 3 38 80 36 0 85 225 0.9 3 73 5 7 26 37 79 3 250.0 3 7 72 26 76 29 ENERGY PERFORMANCE NET C F L/S CFM M 3 /H POWER CONSUMED WATTS RECOVERY EFFICIENCY APPARENT LATENT RECOVERY/ MOISTURE EFFECTIVENESS TRANSFER HEATING 0 32 23 50 85 3 65 7 0.0 0 30 6 09 58 62 70 0.0 0 39 83 70 59 66 0.0-25 -3 23 8 82 56 60 78 0.0-25 -3 30 6 09 6 55 72 0 COOLING VK0055A TOTAL RECOVERY EFFICIENCY 35 95 - - - - NOT TESTED 2 (5 mm) 3: FRESH AIR FROM OUTSIDE PORT : EXHAUST AIR TO OUTSIDE PORT VÄNEE HRV 60H (PORTS ON TOP) 93 6 (503 mm) 6¼ (3 mm) NOTE: All specifications are subject to change without notice. Model: HRV 60H Core filters: 30 ppi washable foam Speed control on unit: Low & high speeds. Part number top ports: 602 0.5 x 6.75 x 0.5 (26.7 cm x 7.2 cm x.3 cm) Other modes available with main and Part number side ports: 600 Housing: Pre-painted steel optional wall controls Total assembled weight (including Insulation: Expanded polystyrene Heat recovery core: polypropylene core): 2 lb. (9 kg) Mounting: Suspension by chains - Heat exchange surface area: 55 ft. 2 (5. m 2 ) and springs - Type/Material: Crossflow/Polypropylene Oval shaped ports; fit 5 diameter ducts Supply and exhaust blower motor: 2 motors Unit electrical characteristics: Drain: /2 (.2 cm) fittings with - Protection type: Thermally protected Volts Frequency Ampere Watts 0 ft. (3 m) PVC drain hose - Insulation class: B 20 60 Hz 0.85 00 VK0056A ALL PORTS FITS 22 9 6 (57 mm) 23¾ (603 mm) : FRESH AIR TO PORT 2: EXHAUST AIR FROM PORT 3: FRESH AIR FROM OUTSIDE PORT : EXHAUST AIR TO OUTSIDE PORT (02 mm) 6 (52 mm) 6 (30 mm) 2½ (6 mm) Project: Location: Part no.: Qty.: Submitted by: Date: REMARKS 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: -800-567-3855 Fax: -800-567-75 www.vanee.ca 3/ PRODUCT SHEET NO. 909
HEAT RECOVERY VENTILATOR vänee 90H-V Part no. 60630 67 to 57 CFM (0. in. w.g.) VB025 THE NEWEST ADDITION TO OUR POPULAR BRONZE FAMILY The contractor s priority is to offer affordable improved indoor air quality to the customer. At vänee, we also share this vision: provide a reliable product that will ensure the homeowner a healthier environment. The 90H-V offers all the basic features for the new construction market, such as integrated balancing dampers and a defrosting system without negative pressure. Moreover, all aspects of its design were thought to ease balancing of air flow and simplify installation; it also offers easy access to electronic components. Designed with 2 PSC motors, the 90H-V improves indoor air quality and reduces excess humidity, ensuring a continuous supply of fresh air from outside into the house. Faster and easier installation of insulated flexible ducts with practical straps Integrated balancing dampers Easy to access electronic module Homeshield defrosting system (no negative pressure) Heat recovery core offers greater comfort Designed with 2 PSC high pressure blowers Integrated draining system with antimicrobial coating ENERGY STAR qualified REPAIRS AND MAINTENANCE The 90H-V low power consumption PSC motors are permanently lubricated. The electronic circuit board eliminates electromechanical parts, reducing repair time to a minimum. WARRANTY The 90H-V unit is protected by a complete 2-year warranty on all parts. The heat recovery core is covered by a limited lifetime warranty, with the original proof of purchase. Available at : Controls This unit is very simple to operate. Once it is installed, press on its push button, located under the unit, to activate it. Press once for low speed, once again for high speed, and once more to stop it. The following main controls are also available: - Digital control Deco-Touch* no. 0295 - Lite-Touch Bronze no. 0270 - Bronze no. 0250 * Recirculation mode not available. Also, to 5 of the following optional controls can be added: - 20-min. Lighted push button no. 8060-60-min. Mechanical timer no. 0090 For more details about controls, refer to their specification sheet on vanee-ventilation.com. Options Complete line of registers and diffusers Electric duct heater Homeshield Defrosting System The 90H-V uses a unique defrosting method. No negative pressure is created by air exhausted to the outside, as the air is recirculated into the house, helping to prevent any backdraft. VF006 STALE AIR FILTERED AIR FROM TO Heat Recovery Core OUTSIDE C F THAN -5 THAN 23 DEFROST CYCLE DEFROSTING MIN./ OPERATING MIN. NO DEFROST -5 TO -27 23 TO -7 7 / 25-27 -7 0 / 22 Dimensions: 0 x 0 x.25 (25. cm x 25. cm x 36.2 cm) Exchange surface: 00 ft2 Weight: 7.26 lb (3.3 kg) Material: Polypropylene Type: Cross flow Warranty: Limited lifetime Requirements and standards Complies with the UL 82 requirements regulating the installation of Heat Recovery Ventilators Complies with the CSA C22.2 no. 3 Standard applicable to ventilators Complies with CSA C requirements regulating the installation of Heat Recovery Ventilators Technical data was obtained from published results of tests relating to CSA C39 Standards HVI certified and ENERGY STAR qualified
DIMENSIONS AND SERVICE CLEARANCE: VÄNEE 90H-V 23 9 /6 (599 mm) 2 ¹/6 (53 mm) 2 9 /6 (62 mm) 22 ½ (572 mm) 2 3 3 3 /6 (97 mm) 7 7 /6 (89 mm) VK0066A /6 (358 mm) 5 /6 (380 mm) VENTILATION PERFORMANCE EXT. STATIC PRESSURE NET GROSS POWER CORD 3 FT EXHAUST Pa in. w.g. l/s cfm m 3 /h l/s cfm m 3 /h l/s cfm m 3 /h 25 0. 9 93 328 92 95 33 9 9 328 50 0.2 86 80 86 83 30 86 80 75 0.3 80 70 288 8 7 292 80 69 288 00 0. 7 57 266 7 58 266 7 57 266 25 0.5 67 2 2 67 3 2 69 7 28 50 0.6 62 223 63 223 63 33 227 75 0.7 55 7 98 56 8 202 57 20 205 200 0.8 7 0 69 8 0 73 9 0 76 225 0.9 0 86 87 8 3 92 55 250.0 33 7 9 3 7 25 7 26 8 ¼ (6 mm) EXTERNAL STATIC PRESSURE IN. W.G. (PA = N X 28.36).2.0 0.8 0.6 0. 0.2 NOTE: Every port fits 6 round duct. : EXHAUST AIR TO OUTSIDE PORT 2 : FRESH AIR FROM OUTSIDE PORT 3 : EXHAUST AIR FROM PORT : FRESH AIR TO PORT 0.0 0 25 50 75 00 25 50 75 200 VG0082A GROSS (CFM) EXHAUST (CFM) PCM (L/S = PCM X 0.79) (M 3 /H = L/S X 3.6) ENERGY PERFORMANCE NET C F L/S CFM POWER CONSUMED WATTS RECOVERY EFFICIENCY APPARENT LATENTE/RECOVERY MOISTURE EFFECTIVENESS TRANSFER HEATING 0 32 67 56 70 78 0.00 0 32 0 86 6 68 75 0.0 0 32 56 20 86 6 70 0.0-25 -3 30 63 79 6 83 0.0 NOTE: All specifications are subject to change without notice. SPECIFICATIONS Model: 90H-V Insulation: Expanded polystyrene Housing: pre-painted steel Part number: 60630 Mounting: Suspension by chains and springs Heat recovery core: Total assembled weight (including 2 PSC motors (supply and exhaust blower - Heat exchange surface area: 00 ft 2 (9.3 m 2 ) polypropylene core): 52.0 lb. (23.6 kg) motors) - Type: Cross flow Ovale shaped ports: fit 6 round ducts - Protection type: thermally protected - Material: Polypropylene Drains: /2 (.2 cm) fittings with - Insulation class: F 0 ft (3 m) PVC drain hose Speed control on unit: Unit electrical characteristics: Core filters: 2 washable MERV 7 - Low and High speed Volts Frequency Ampere Watts 9.2 x.25 x 3.8 - Other modes available with 20 60 Hz.0 25 (23. cm x 36.2 cm x 9.6 cm) Lite-Touch or Deco-Touch main control Project: Location: Part no.: 60630 Qty.: Submitted by: Date : REMARKS 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: -800-567-3855 Fax: -800-567-75 www.vanee-ventilation.com 3/0 FICHE TECHNIQUE 98