SECTION HEATING BOILER FEEDWATER EQUIPMENT

Similar documents
BuildingName The Description of the Project P DOCUMENTS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

SECTION PLUMBING EQUIPMENT

SECTION STEAM CONDENSATE PUMPS

Design and Construction Standards SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT

SECTION HEATING BOILERS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

SECTION STEAM CONDENSATE PUMPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION AIR COOLED WATER CHILLERS

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

TECHNICAL. Series 18. Pump Packages

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

SECTION ROTARY-SCREW WATER CHILLERS

Custom Design TYPE CS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

SECTION FIRE PUMP AND CONTROLS

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Condensate Boiler Feed Water Make-Up

.2 Section Waste Management and Disposal.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

SECTION AIR DUCT ACCESSORIES

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Domestic Pump Condensate Transfer Equipment

Deaerator. Specifications

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

SECTION STEAM CONDENSATE PUMPS

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed Pumps and Custom Design TYPE SHEM. BULLETIN 107 Revised 5/17

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

SECTION WATER-TUBE BOILERS

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

Silhouette. Feedwater Heater. Boiler Feedwater

.005 ATMOSPHERIC DEAERATOR

Hoffman Specialty Pump Products

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

SECTION CENTRIFUGAL WATER CHILLERS

SECTION DOMESTIC WATER HEATERS

DEAERATORS .005 ATMOSPHERIC DEAERATOR

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

SECTION COOLING TOWERS

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

UNIFIED FACILITIES GUIDE SPECIFICATIONS

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

.03 ATMOSPHERIC DEAERATOR

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SECTION CHILLERS

SECTION METERS AND GAGES FOR PLUMBING PIPING

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

STERO SCT-94SC/108SC/120SC CONVEYOR SERIES

University of Delaware

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

SECTION DOMESTIC WATER PUMPS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

B. Section Transfer Switches: Automatic transfer switch.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

Packaged Steam Fired Water Heater

SECTION AIR COILS

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

UNDP / PAPP OFFICE BUILDING RAMALLAH HVAC WORKS

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

FEATURES. Other Fed-Flush Arrangements

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

SECTION AIR COMPRESSORS AND ACCESSORIES

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

SECTION COOLING TOWERS

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

CONTENTS AUTOMATIC TRANSFER SWITCHES

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

SECTION HUMIDITY CONTROL EQUIPMENT

CxA to Answer this Section

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Transcription:

SECTION 23 53 00 HEATING BOILER FEEDWATER EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes boiler feedwater pumps, de-aerators, accessories, controls and tanks. 1.2 REFERENCES A. ASME (American Society of Mechanical Engineers) - Boiler and Pressure Vessel Codes, SEC VIII-D - Rules for Construction of Pressure Vessels. B. NEMA 250 (National Electrical Manufacturers Association) - Enclosures for Electrical Equipment (1000 Volt Maximum). 1.3 PERFORMANCE REQUIREMENTS A. Ensure pumps operate at specified system fluid temperatures without vapor binding and cavitation, are non-overloading in parallel or individual operation, and operate within 25 percent of midpoint of published maximum efficiency curve. 1.4 SUBMITTALS A. Section 01 33 00 - Submittal Procedures: Submittals procedures. B. Product Data: Submit certified pump curves showing performance characteristics with pump and system operating point plotted. Include NPSH curve when applicable. Include electrical characteristics and connection requirements. Submit also, manufacturer model number, dimensions, service sizes, and finishes. C. Manufacturer's Installation Instructions: Submit application, selection, and hookup configuration with pipe and accessory elevations. Submit hanging and support requirements and recommendations. D. Manufacturer's Certificate: Certify that products meet or exceed specified requirements. 1.5 CLOSEOUT SUBMITTALS A. Section 01 77 00 Closeout Procedures: Closeout procedures. February 2018 Page 1 of 6 2018 FDG Section 23 53 00

B. Operation and Maintenance Data: Submit installation instructions, servicing requirements, assembly views, lubrication instructions, and replacement parts list. 1.6 QUALITY ASSURANCE A. Perform Work in accordance with applicable codes and laws as well as the Stanford Facilities Design Guidelines and all Stanford University Contract documents. B. Maintain one copy of each document on site. 1.7 QUALIFICATIONS A. Manufacturer: Company specializing in manufacturing products specified in this section with minimum three years documented experience 1.8 DELIVERY, STORAGE, AND HANDLING A. Accept units on site in factory packing. Inspect for damage. B. Protect units from entry of foreign materials by using temporary caps and covers. 1.9 FIELD MEASUREMENTS A. Verify field measurements prior to fabrication. 1.10 WARRANTY SEE EQUIPMENT LIST A. Section 01 77 00 Closeout Procedures: Product warranties and product bonds. B. Provide five year manufacturer warranty for pumps and package units. 1.11 EXTRA MATERIALS SEE EQUIPMENT LIST A. Section 01 77 00 Closeout Procedures: Spare parts and maintenance products. PART 2 - PRODUCTS 2.1 DEAERATORS A. Deaerator System: Consists of storage tank, surge tank, boiler feed pumps, transfer pumps, float switches, control panel and accessories. B. Deaerator Storage Tank: 1. Horizontal welded steel, ASME SEC 8-D stamped construction 2. Working Pressure: 125 psig. February 2018 Page 2 of 6 2018 FDG Section 23 53 00

3. Manhole: 11 x 15 inch. 4. Base: Elevated, fabricated steel. C. Storage Tank Accessories: 1. ¾ inch inlet water regulating valve with external float control assembly. 2. Steam pressure-reducing valve. 3. Water level gage glass. 4. Manual and automatic vent valves. 5. Pressure relief valve. 6. Thermometer. 7. Pressure gage. 8. Adjustable inlet spray valve. 9. Overflow drain. 10. Manual drain valve. 11. Pressure gages on each pump discharge. 12. Bronze isolation valves and strainers between boiler feed pumps and tanks. 13. Double pole high and low level alarm float switches. D. Surge Tank: 1. Horizontal welded steel, ASME SEC VIII-D stamped construction. 2. Working Pressure: 125 psig. 3. Manhole: 11 x 15 inch. 4. Base: Elevated, fabricated steel. E. Surge Tank Accessories: 1. ¾ inch float actuated inlet water regulating valve. 2. Water level gage, glass. 3. Pressure relief valve. 4. Thermometer. 5. Pressure gage. 6. Inlet diffuser. 7. Overflow drain. 8. Manual drain valve. 9. Pressure gages on each pump discharge. 10. Bronze isolation valves and strainers between transfer pumps and tank. 11. Double pole low level alarm float switch. F. Boiler Feed Pumps: February 2018 Page 3 of 6 2018 FDG Section 23 53 00

1. Pumps: Two stage, vertical or horizontal per design, bronze fitted with stainless steel shaft, bronze impeller, renewable bronze case ring, mechanical shaft seal, close coupled to 3500 rpm motor. G. Transfer Pumps: 1. Pumps: Vertical or Horizontal per design, bronze fitted with stainless steel shaft, enclosed bronze impeller, renewable bronze case ring, mechanical shaft seal, close coupled to motor. H. Control Cabinet: 1. NEMA 250 enclosure, UL listed, with piano hinged door, grounding lug terminal strip and fusible control circuit transformer. 2. Combination magnetic starters with overload relays, circuit breakers and cover interlock. 3. Electric alternator, 'Auto-Off' switch. a) Operate pumps on high level, alternating after each cycle. b) Operate second pump upon failure of first pump and alarm. 4. Selector 'lead-off-lag' switches. 5. Alarm lights, acknowledge button, test buttons, alarm horn. I. Control Sequence: 1. Operate transfer pumps on high level alternating after each cycle. Operate second transfer pump upon failure of first pump and alarm. 2. Operate boiler feed pumps from boiler controls. 2.2 LOW PRESSURE BOILER FEED UNITS A. Boiler Feed Units: Consisting of receiver, inlet strainer, pumps, water make-up assembly, electric control components and accessories. B. Condensate Receiver: Cast iron, equipped with water level gage, dial thermometer, bronze isolation valves and strainer between pumps and receiver, and lifter eye bolts. C. Inlet Strainer: Cast iron, with vertical self-cleaning easily removable bronze screen and large dirt pocket, mounted on receiver. D. Water Make-up Assembly: 1. Consists of level control switch and solenoid valve mounted on receiver. 2. Valve: February 2018 Page 4 of 6 2018 FDG Section 23 53 00

E. Pumps: Stanford University Facilities Design Guidelines a. Packless, piston pilot operated type with cushioned closing and epoxy resin molded waterproof coil. b. Capacity: Equal to one boiler feed pump. c. With strainer, and manual bypass. 1. Vertical or Horizontal per design, bronze fitted with stainless steel shaft, enclosed bronze impeller, renewable bronze case ring, mechanical shaft seal, close coupled to motor. 2.3 HIGH PRESSURE BOILER FEED UNITS A. Boiler Feed Units: Consist of receiver, inlet strainer, pumps, water make-up assembly, electric controls and NEMA 250 control cabinet, and accessories. B. Condensate Receiver: Horizontal welded steel construction with cradles, inlet cascade baffle and dished heads. C. Inlet Strainer: With self-cleaning bronze screen and large dirt pocket on receiver. Screen shall be vertically removable for cleaning. D. Water make-up Assembly: 1. Consists of level control switch and solenoid valve mounted on receiver. 2. Valve: E. Accessories: a. Packless, piston pilot operated type with cushioned closing and epoxy resin molded waterproof coil. b. Capacity: Equal to one boiler feed pump. c. With strainer, and manual bypass. 1. Water level gage. 2. Dial thermometer. 3. Low water cut-off switch. 4. Pressure gages on pump discharge. 5. Bronze isolation valves and strainer between pumps and receiver. F. Pumps: February 2018 Page 5 of 6 2018 FDG Section 23 53 00

2.4 RECEIVERS Stanford University Facilities Design Guidelines 1. Two stage, vertical or horizontal per design, bronze fitted with stainless steel shaft, bronze impeller, renewable bronze case ring, mechanical shaft seal, close coupled to 3500 rpm motor. A. Condensate Receiver: Horizontal welded steel, ASME SEC 8-D stamped construction for 125 psig working pressure with elevated, fabricated steel base and equipped with taps for mounting float switches, water level gage, thermometers, pump suction fittings, condensate inlet, and lifting eye bolts. 2.5 ELECTRICAL CHARACTERISTICS AND COMPONENTS A. Disconnect Switch: Factory mount in control panel PART 3 - EXECUTION 3.1 EXAMINATION A. Verify power requirements. B. Verify boilers and water system are ready for installation. 3.2 FIELD QUALITY CONTROL A. Section 01 77 00 Closeout Procedures: Testing, adjusting, and balancing. B. Inspect for alignment of base mounted pumps. END OF SECTION February 2018 Page 6 of 6 2018 FDG Section 23 53 00