Light Duty Commercial Electric Voltage and Wattage Conversion Instructions

Similar documents
Light Duty Commercial Electric Voltage and Wattage Conversion Instructions

CONVERSION KIT INSTRUCTIONS Commercial Electric Water heaters

CONVERSION KIT INSTRUCTIONS

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Residential Upright Residential Lowboy

Audi-Larm Audible Alarm

Commercial Electric Energy Saver Water Heater IMMERSION AND SURFACE MOUNTED THERMOSTAT MODELS

WATTS WALL-MOUNT WIDESPREAD BATHROOM FAUCET INSTALLATION

D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

IB 835. Installation Manual. Integrated Bidet Toilet TABLE OF CONTENTS

V Refrigeration Module

HOT WATER BOTTLE BATH PART NUMBER

DELEVINGNE WIDESPREAD FAUCET INSTALLATION

V Refrigeration Module

TARVER SINGLE HOLE FAUCET INSTALLATION

DRAIN WATER TEMPERING INSTALL

Parts & Material Included

BROEG SINGLE HOLE FAUCET INSTALLATION

LED IMPORTANT SAFETY INSTRUCTIONS

LUDGATE SINGLE HOLE FAUCET INSTALLATION

PAGOSA SINGLE HOLE FAUCET INSTALLATION

5800 Refrigerator Compressor Capacitor/Relay Kit

EUTECTIC EC-20 OIL-FIRED WATER BOILERS/NO. 2 OIL ASSEMBLY INSTRUCTIONS EUTECTIC EC-20 ASSEMBLY GUIDE

Platen Heater Pad Replacement

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

RYLE WIDESPREAD FAUCET INSTALLATION

KITCHEN FAUCET COS-KF222C

1500W PTC element (230V)

Heat Exchanger Block Replacement Instructions

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Concepts Serving Systems

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

HX Field Replacement Kit

English, French & Spanish No Color

M5 BLUE BOY FIVE GALLON PAINT MIXER Owner s Manual

*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 1000 ft. above sea level.

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

STONE TROUGH CONSOLE SINK

Installation Manual. Models 99168, 99169, 99170

AVENGER HT THERMOSTAT RETROFIT INSTRUCTIONS

PROPANE CONVERSION INSTRUCTIONS. Applies to: Gas-Fired, Tubular Radiant, Low-Intensity Infrared Heater

CONTEMPORARY KITCHEN AND PREP FAUCET INSTALLATION INSTRUCTIONS

TECHNICAL INSTRUCTIONS

Panel Mounted Heat Exchangers by Dantherm, Inc.

INSTALLATION & SERVICE MANUAL

569, 570, 571, 572 Series

Water Distiller Service Manual

FIREPLACE INSTALLATION

Single-Control Lavatory Faucet

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

TRADITIONAL PLP PULLDOWN FAUCET INSTALLATION INSTRUCTIONS. Model #s: 5500, 5600, 5610, 5200, 5210

WIDESPREAD KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE

SuperKlean Washdown Products

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

TRADITIONAL KITCHEN AND PREP FAUCET INSTALLATION INSTRUCTIONS

Installation Instructions EFS Hand Washing Station

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

Undercounter Refrigeration

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Food Waste Disposer Instruction Manual

Installation Instructions Air Pump

! WARNING. Before using product, read and understand instructions.

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

AUBEREE CENTERSET FAUCET INSTALLATION

INSTALLATION INSTRUCTIONS

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

FLT93 Installation, Operation and Troubleshooting Guide

AUTOMATIC ICE-CUBE MAKER

TRADITIONAL PLP PULLDOWN FAUCET INSTALLATION INSTRUCTIONS. Model #s: 5500, 5600, 5610, 5200, 5210

Installation Instructions Built-In Dishwasher

TECHNICAL INSTRUCTIONS

DRAIN WATER TEMPERING INSTALL

Installation Instructions

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions

Food Waste Disposer Instruction Manual

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

INSTALLATION & OPERATING INSTRUCTIONS

MENZA CENTERSET FAUCET INSTALLATION

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

569, 570, 571, 572 Series

NISSAN FRONTIER INSTALLATION INSTRUCTIONS

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

To Purchase This Item, Visit BMI Gaming Mechanical Beverage Vendor.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Page 2 of 5. SOP SF SOP for Water Bath Maintenance

Installation Instructions

SERVICE MANUAL. Kleenmaid SMART oven OMFHS6010

Non-RTD Hot Melt Hose Replacement

Model/Sprinkler Identification Numbers

Installation Instructions

! WARNING. Before using product, read and understand instructions.

EDISON DUAL HANDLE VESSEL SINK FAUCET

Decorative Low Profile Integrated Kit

Transcription:

Light Duty Commercial Electric Voltage and Wattage Conversion Instructions Conversion to be performed by a Qualified Service Person only. Underwriters Laboratories Inc. recognizes this procedure as herein presented and no deviation from these instructions are allowed. LDWH-6U LDWH-12U LDWH-20L LDWH-30L LD-20L LD-30L LD-30R LD-40L LD-40S LD-50L LD-50S LD-65R LD-80R LD-120R LD-6U LD-10U LD-12U LD-12UT LD-15U LD-20U LD-30U Page 1 of 5 238-46411-00A

The conversion procedure outlined in the instruction manual is to be executed only by Qualified Service Personnel. Read these instructions first before proceeding with the conversion. The purpose of this instruction manual is to instruct about the changing of wattage and voltage for Light Duty Commercial Electric water heaters manufactured by Bradford White Corporation. Underwriters Laboratories Inc. recognizes this procedure as herein presented and no deviation from these instructions are allowed. Special factory prepared kits must be used for these conversions. Below is a list of the kits that have been prepared for the various wattages and voltages. These instructions do not allow for the modification that adds or deletes the number of heating elements originally supplied with the water heater; therefore such a modification must not be attempted. Voltage and Wattage conversion kit part numbers: Non-Simultaneous Simultaneous Voltage Wattage Max Wattage Max Wattage 120 208 240 277 1500 1500 3000 265-46409-01 265-46409-05 265-46409-13 265-46409-16 2000 2000 4000 265-46409-02* 265-46409-06 265-46409-05 265-46409-17 2500 2500 5000 265-46409-03* 265-46409-07 265-46409-06 265-46409-18 3000 3000 6000 265-46409-04* 265-46409-08 265-46409-14 265-46409-19 3500 3500 7000 N/A 265-46409-09 265-46409-07 N/A 4000 4000 8000 N/A 265-46409-10 265-46409-08 265-46409-20 4500 4500 9000 N/A 265-46409-11 265-46409-09 265-46409-21 5000 5000 10000 N/A 265-46409-12 265-46409-15 265-46409-22 5500 5500 11000 N/A 265-46409-46* 265-46409-10 265-46409-40 6000 6000 12000 N/A 265-46409-47* 265-46409-48* 265-46409-23 * These kits contain only one (1) element. These are non-simultaneous kits only. Wattage Non-Simultaneous Max Wattage Simultaneous Max Wattage 380 Voltage 415 480 1500 1500 3000 265-46409-24 265-46409-41 265-46409-32 2000 2000 4000 265-46409-43 265-46409-24 265-46409-33 2500 2500 5000 265-46409-25 265-46409-43 265-46409-34 3000 3000 6000 265-46409-26 265-46409-25 265-46409-35 3500 3500 7000 265-46409-27 265-46409-26 N/A 4000 4000 8000 265-46409-29 265-46409-27 265-46409-36 4500 4500 9000 265-46409-30 265-46409-28 265-46409-37 5000 5000 10000 265-46409-31 265-46409-29 265-46409-38 5500 5500 11000 265-46409-44 265-46409-30 265-46409-42 6000 6000 12000 265-46409-45 265-46409-31 265-46409-39 Tools required for conversion: 1. 1 ½" deep-well socket or wrench. 2. Phillips head screwdriver. 3. ¼" nut-driver or socket. 4. Thread lubricant.! WARNING High voltage potential exposure. To avoid personal injury, be sure water heater is disconnected from power source prior to performing the procedure. Page 2 of 5

(s) Removal: 1. Turn off electrical power to water heater, DISCONNECT FROM POWER SOURCE. 2. Drain water heater. screw 3. element access cover(s). access cover 4. Insulation. insulation 5. thermostat(s) protector. thermostat protector Page 3 of 5

6. Disconnect wire leads from element(s) terminal block. terminal block Disconnect wire leads from element terminal block 7. element(s) from tank using 1½" deep well socket or wrench. Unscrew element(s) counter-clockwise to remove from tank. Unscrew element(s) counter-clockwise to remove from tank (s) Installation: 8. Check element terminal block for proper electrical rating. Note: Some elements have a dual rating, so be sure to check all surfaces on element terminal block. Check rating(s) on element Page 4 of 5

9. Apply new gasket(s) to new element(s) from conversion kit. Note: Make sure gasket is seated flat against element flange without rolls or gaps. Gasket 10. Thread new element(s) clockwise into tank. Tighten element(s) with a 1 ½" deep well socket or wrench. Do not over tighten. Over-tightening may damage gasket. flange Note: Clean any debris from element(s) fitting to tank. Lubricate element(s) threads as needed with thread lubricant. 11. Be sure tank is filled with water and check for leaks. 12. Reconnect wire leads to element(s) terminal block. 13. Replace thermostat(s) protector and insulation. Thread element(s) clockwise into tank 14. Replace access cover(s). 15. Restore electrical power. Reconnect wires leads to element(s) terminal block 16. Place appropriate label (supplied with kit) so it covers electrical information on water heater rating plate. Note: Be certain not to cover model number, serial number and capacity information. Cover electrical information only with appropriate overlay Water heater rating plate Page 5 of 5