CIRCUIT BREAKER FAIL PROTECTION

Similar documents
ANCILLARY LIGHT CURRENT EQUIPMENT

STCP 02-1 Issue 005 Alarm & Event Management

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

AS/NZS TR IEC :2012

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

TECHNICAL SPECIFICATION

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

POWER SYSTEM INCIDENT REPORT: TRIP OF DOUBLE CIRCUIT MACKAY- COLLINSVILLE TEE - PROSERPINE 132 KV LINES AND STRATHMORE SVC ON 29 DECEMBER 2010

INTERNATIONAL STANDARD

KFP-CF Series Operation Manual

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Control Of Points. Withdrawn Document Uncontrolled When Printed. Railway Group Standard. Issue One Date July 1997

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Substations and high voltage installations exceeding 1 kv a.c.

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

Overhead Line Insulators

SCHEDULE 2 - EXHIBIT 1 DATED [ ] NATIONAL GRID ELECTRICITY TRANSMISSION PLC (1) and THE CONNECTION AND USE OF SYSTEM CODE

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

CONNECTION, ENERGISING, COMMISSIONING AND PERMANENT DISCONNECTION OF HIGH VOLTAGE APPARATUS

INTERNATIONAL STANDARD

This document is a preview generated by EVS

GK/GN0612. Guidance on Signalling Lockout Systems to Protect Railway. Undertaking Personnel. Railway Group Guidance for GK/RT0212.

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

PREMIER M PLUS USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 8-24 ZONE CONVENTIONAL FIRE ALARM PANEL LOG BOOK & CERTIFICATES

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

LOG BOOK & CERTIFICATES

ISO INTERNATIONAL STANDARD

TECHNICAL SPECIFICATION

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

Policy and Specification for the Interface with Independent Distribution Network Operators Installations

LABORATORY ILLUMINATED FLOTATION BATH

ISO INTERNATIONAL STANDARD. Road vehicles Alarm systems for buses and commercial vehicles of maximum authorized total mass greater than 3,5 t

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

This is a preview - click here to buy the full publication

INTERNATIONAL STANDARD

TECHNICAL REPORT IEC/TR High-voltage direct current (HVDC) systems Application of active filters. Edition

Substation Signage. Document Number: 1-11-FR-12

INTERNATIONAL STANDARD

TECHNICAL SPECIFICATION

AS/NZS IEC :2016

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

August 2013 Technical Requirements for Remote Controlled Temporary Traffic Management Signs for use on the Highways Agency Strategic Road Network

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

Installation and Operations Manual

SEL Arc-Flash Solutions

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

This is a preview - click here to buy the full publication

Fact File 48 Guide to BS EN 54-13:2017 Fire Detection and alarm systems:

INTERNATIONAL STANDARD

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

SEL Arc-Flash Solutions

INTERNATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

INTERNATIONAL STANDARD

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Loss Prevention Standard

This document is a preview generated by EVS

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Technical Specification for Remote Controlled Temporary Traffic Management Signs for use on the Highways Agency Strategic Road Network

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

DRAFT TANZANIA STANDARD

OWNERS MANUAL MODEL 451 (-101 & -201)

This document is a preview generated by EVS

Lecture 4 Power System Protection. Course map

VAMP 120 & 121. Arc flash detection units. Product picture

AS/NZS IEC :2015

INTERNATIONAL STANDARD

GMA Panels with double busbar

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

INTERNATIONAL STANDARD

Transcription:

CIRCUIT BREAKER FAIL PROTECTION This document is for Relevant Electrical Standards document only. Disclaimer NGG and NGET or their agents, servants or contractors do not accept any liability for any losses arising under or in connection with this information. This limit on liability applies to all and any claims in contract, tort (including negligence), misrepresentation (excluding fraudulent misrepresentation), breach of statutory duty or otherwise. This limit on liability does not exclude or restrict liability where prohibited by the law nor does it supersede the express terms of any related agreements." TABLE OF CONTENTS PURPOSE AND SCOPE... PART TECHNICAL REQUIREMENTS... FUNCTIONAL REQUIREMENTS... 2 PERFORMANCE REQUIREMENTS... 4 3 TEST REQUIREMENTS... 4 4 FORMS AND RECORDS... PART 2 - DEFINITIONS AND DOCUMENT HISTORY... 5 DEFINITIONS... 6 AMENDMENTS RECORD... PART 3 - GUIDANCE NOTES AND APPENDICES... 7 REFERENCES... PURPOSE AND SCOPE This document describes the technical requirements for User s equipment directly connected to the England and Wales Transmission system within NGET s (National Grid Electricity Transmission) busbar protection zone. Nominal voltages of 400 kv, 275 kv, 32 kv and 66 kv apply unless otherwise agreed with the user as defined in the Bilateral agreement. This shall include all protection and control devices operating NGET Switchgear. The principles of this document also applies to the equipment connected at other voltages. This Specification defines the technical requirements for. PART TECHNICAL REQUIREMENTS FUNCTIONAL REQUIREMENTS General. Circuit breaker fail protection shall cause cessation of fault current within 300 ms of inception of the original fault whose detection initiated tripping of the failed circuit breaker. Circuit Breaker Fail Detectors.2 Circuit breaker fail detector(s) shall be enabled when the protected circuit breaker has been called upon to trip by operation of its associated protection systems..3 The detector(s) shall not operate if the circuit breaker fails to open during a routine switching operation or automatic switching sequence unless such failure coincides with or precipitates the development of a system fault, resulting in the operation of its associated protection systems..4 A detector shall comprise the following: Uncontrolled When Printed Page of

a) A current check element to check if current is still flowing in any phase of the circuit breaker following circuit breaker trip initiation. b) A timing element to delay tripping until the circuit breaker has had adequate time for normal extinction of fault current. Informative: Acceptable arrangements of the current check element and timing element to form a detector are shown in Figures 3 and 4..5 For Option A (see Fig. 3): a) The current check element shall be enabled by the circuit breaker fail initiating inputs to monitor the current flowing through the circuit breaker. b) Detection of current in any phase of the circuit breaker above setting shall start and maintain the timing element. c) A trip output from the detector shall be initiated if the current is still above setting at the end of the timing period..6 For Option B (see Fig. 4): a) The timing element shall be started directly from the circuit breaker fail initiating inputs. b) The current check element shall be enabled by the timing element at the end of the timing period and shall monitor the current flowing through the circuit breaker. c) If the current in any phase of the circuit breaker is above setting, then a trip output from the detector shall be initiated. d) For applications using this arrangement, specific measures shall be taken to prevent unwanted back tripping for situations where the circuit breaker has been called upon to close when a trip relay (circuit breaker fail initiating contact) has been operated and not reset. Informative: One such measure would be to block circuit breaker closing for the duration of trip relay operation..7 The method of preventing unwanted back tripping shall be declared by the supplier. Current Check Function.8 The function shall comply with IEC 60255-5..9 The function shall have, as a minimum requirement, a current setting range of 5% to 25% in steps of 5% or 30% to 00% in steps of 0% depending upon the design of the circuit breaker. Additional step ranges may also be applicable as appropriate. Informative: The setting range specified is based on the assumption that the rating of the current check element is A and that the ratio of the current transformer is 2000/000/ at 400 kv and 200/600/ at 275 kv. However, a current rating of 5A and different CT ratios could equally apply. Timing Function.0 The timing function shall comply with IEC 680-. The timing function shall have, as a minimum requirement, a time setting range of 50 ms to 250 ms in steps of 2 ms. Uncontrolled When Printed Page 2 of

Circuit Breaker Fail System.2 Where the circuit breaker fail detector is a software function embedded in a multi-function numerical relay, such as busbar protection, one detector shall initiate tripping of contiguous circuit breakers..3 Where the circuit breaker fail detector is affected by discrete conventional relays, two detectors operating in a two-out-of-two mode shall initiate tripping of contiguous circuit breakers. Interfaces.4 Where the is not integrated with the busbar protection, it shall normally be supplied from a three phase set of measurement/protection class current transformers..5 The circuit breaker fail protection shall be initiated by a single point digital output from each of the protection systems that can initiate tripping of the protected circuit breaker. Informative: The single point digital input is normally a trip relay contact..6 Inputs to the shall be immune from maloperation due to wiring earth faults. Informative: Double pole switching is one accepted way of ensuring immunity from maloperation. Outputs Busbar Stations.7 The shall initiate back tripping of all other circuit breakers connected to the same busbar via the tripping system of the busbar protection..8 Where the is not integrated with the busbar protection, a minimum of two single point outputs shall be provided to initiate backtripping..9 The back tripping initiations shall be immune from maloperation due to wiring earth faults. Informative: Double pole switching is one accepted way of ensuring immunity from maloperation..20 Where the protection system is associated with a feeder circuit breaker such that tripping of directly connected remote circuit breaker(s) is required, then initiation shall be provided for the DTT and PTT, as provided for the feeder. Informative: A typical logic diagram for a feeder circuit breaker fail protection system at a busbar substation is shown in Figure 5. Outputs Mesh Stations.2 The protection system shall be provided with single point outputs for each mesh corner to initiate back tripping of all associated local and directly connected remote circuit breakers. Informative: An accepted way of initiating back tripping is to use the tripping system of both first and second mesh corner protections. A typical logic diagram for circuit breaker fail protection systems at a mesh substation is shown in figure 6. Uncontrolled When Printed Page 3 of

Alarm Outputs.22 The following single point outputs shall be provided for the circuit breaker fail protection system alarms as appropriate: a) Circuit breaker fail protection operated. b) Protection supply supervision. c) Protection relay defective. d) Trip relay operated indication, where a trip relay is provided. 2 PERFORMANCE REQUIREMENTS Current Check Function 2. The operating time shall not be greater than 0 ms. 2.2 The drop off/pick up ratio shall not be less than 70%. 2.3 For Option A the resetting time shall not be greater than 2 ms for operating currents of up 30 times rating (ie 30 A) with a system /R ratio of 40. Informative: This is the minimum time required to ensure the current check function resets quickly enough for the conditions specified above to prevent incorrect operation. 2.4 For Option B the resetting time shall not be greater than 30 ms. 2.5 The error of the function shall not be greater than 5%. Timing Function 2.6 The reset or disengage time of the function shall not be greater than 30 ms. 2.7 For Option A, only the overshoot of the function shall be not greater than 0 ms. 3 TEST REQUIREMENTS 3. The current check function shall be tested in accordance with the requirements of IEC 60255-5 to demonstrate that it meets the requirements of Clauses 4. to 4.5. 3.2 The timing function shall be tested in accordance with the requirements of IEC 680- to demonstrate that it meets the requirements of Clauses 4.6 and 4.7. Uncontrolled When Printed Page 4 of

BUSBAR 05 DISCRETE COMPONENT SCHEME CB Fail Detector (See Figs 3A/3B) CB Fail Detector (See Figs 3A/3B) NUMERICAL BUSBAR PROTECTION SCHEME CB Fail Detector 03 Busbar Protection Algorithms LINE NOTE: CT CONNECTIONS SHOWN DEPICT SIGNALS TO CIRCUIT BREAKER FAIL PROTECTION ONLY Figure : Typical CT Arrangement for for Busbar Stations - Feeder Circuit Uncontrolled When Printed Page 5 of

SEE FIGURE 5 2 CB 20 2 CB 220 SGT2 SGT 23 3 LINE 2 203 226 28 20 28 26 03 LINE 224 428 420 220 220 424 LINE 3 203 326 324 320 328 426 403 LINE 4 33 43 SGT3 SGT4 2 CB 320 2 CB 420 Figure 2: Typical CT Arrangement for Circuit Breaker fail Protection for Mesh Stations Uncontrolled When Printed Page 6 of

CIRCUIT BREAKER FAIL 0V DC() t TRIP ENABLE ALARM CT INPUT I 0 Is current above setting No Reset timer Start timer )T=0 No Is current above setting No Has timer reached setting Enable trip output vote LOGIC FLOW DIAGRAM Figure 3: Circuit Breaker Fail Detector - Option A Uncontrolled When Printed Page 7 of

CIRCUIT BREAKER FAIL 0V DC() t TRIP ALARM ENABLE CT INPUT I 0 Start timer )T=0 No Has timer reached setting No Is current above setting Enable trip output vote LOGIC FLOW DIAGRAM Figure 4: Circuit Breaker Fail Detector - Option B Uncontrolled When Printed Page 8 of

NUMERICAL BUSBAR PROTECTION SCHEME PROTECTION OPERATED EVENTS/ALARMS BUSBAR/ BACKTRIP 0V DC() S BACKTRIP INTERTRIP INTERTRIP TRIP RELAY RESET R EVENT LOG/ INDICATION START TRIP RELAY RESET NOTE:- ISOLATABLE SIGNAL Figure 5: Typical Tripping Logic Diagram for System for Busbar Substations - Feeder Circuit Uncontrolled When Printed Page 9 of

FROM 420 PROTECTION MESH CORNER TRIPPING t TRIP 0V DC() 0V DC SUPPLY FAIL ALARM 428 CLOSED 24 CLOSED > S R TRIP MC PROT (SYSTEM ) TRIP MC PROT (SYSTEM 2) EVENT LOG/ INDICATION TRIP RELAY RESET 20 PROTECTION t 0V DC () START TRIP RELAY RESET 0V DC SUPPLY FAIL ALARM 20 2 PROTECTION OPERATED EVENTS/ALARMS MESH CORNER 2 TRIPPING t TRIP 0V DC() 0V DC SUPPLY FAIL ALARM 26 CLOSED 224 CLOSED > S R TRIP MC2 PROT (SYSTEM ) TRIP MC2 PROT (SYSTEM 2) EVENT LOG/ INDICATION TRIP RELAY RESET START TRIP RELAY RESET TO 220 PROTECTION Figure 6: Part of Typical Tripping Logic Diagram for Circuit Breaker Fail Protection System for Mesh Substations Uncontrolled When Printed Page 0 of

Ratings and Requirements for Plant, Equipment and Apparatus for the National Grid System Technical Specification TS (RES) Issue February 204 4 FORMS AND RECORDS Not applicable. PART 2 - DEFINITIONS AND DOCUMENT HISTORY 5 DEFINITIONS Not applicable. 6 AMENDMENTS RECORD Issue Date October 204 Summary of Changes / Reasons Author(s) New document Richard Poole GCRP Approved By (Inc. Job Title) 6. Procedure Review Date 5 years from publication date. PART 3 - GUIDANCE NOTES AND APPENDICES 7 REFERENCES IEC 680- Electromechanical elementary relays- Part : General requirements Edition 3.0 IEC 60255-5 IEC 60255- BS EN 255-22 TS (RES) Measuring relays and protection equipment Part 5: Functional requirements for over/under current protection Edition.0 Measuring relays and protection equipment Part : Common requirements Edition.0 Electrical Relays Electrical Disturbance Tests for Measuring Relays and Protection Equipment Radiated Electromagnetic Field Disturbance Tests Overview National Grid System National Grid 204 204 Copyright owned by National Grid Electricity Transmission plc, all rights reserved. No part of this publication may be reproduced in any material form (including photocopying and restoring in any medium or electronic means and whether or not transiently or incidentally) without the written permission of National Grid Electricity Transmission plc, except:. To the extent that any party who is required to comply (or is exempt from complying) with the provisions under the Electricity Act 989 reasonably needs to reproduce this publication to undertake its licence or statutory duties within Great Britain (or any agent appointed so as to act on that party s behalf); and 2. In accordance with the provisions of the Copyright, Design s and Patents Act 988. Uncontrolled When Printed Page of