The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Similar documents
External venetian blinds

External venetian blinds

Pleated blinds, free hanging units FS, FK, FE Description

External venetian blinds

External venetian blinds sunlight included 40% ENERGY SAVINGS WITH INTELLIGENT SUN SHADING

Vental. The external venetian blind. Vental The external venetian blind. Baumann Hüppe Creators of light and shade

Noval 90. The external venetian blind with linked slats. Noval 90. Linked slats external venetian blind. Baumann Hüppe Creators of light and shade

Silent Gliss. Venetian Blind Systems

Always at the cutting edge. Inspiration 2016

Online Ordering. Swale Blinds has established itself as one of the UK s leading trade only Window Blind suppliers and installers.

and stove-enamelled, incorporating the tilt/raise and lower mechanism. The end caps are colour co-ordinated.

AF-810 and AF-820 Venetian blinds

enviroblinds external blinds & shutters the secret to low carbon comfort

Key benefits. w Recycled content contributes to less greenhouse gas emissions during manufacturing.

Xpert HD Xpert HD 7140, ,

OUTDOOR BLINDS + EXTERIOR VENETIAN BLINDS

External Blinds - Aluflex

Product Range. The UK s leading trade only Window Blind manufacturer

MakroBlind Louvered Shades

VANTA and VANTA+ Venetian blinds

VENTAL V80 EXTERNAL LOUVRE BLINDS External Aluminium Louvre Blinds for Sunshading through Glazed Surfaces V80

made in germany The art of controlling light ARTec Alulux external Venetian blind technology Alulux zip textile screens

External venetian blinds from Griesser. Metalunic

CONTENTS PRODUCTS AND INNOVATIONS OF THE HELLA GROUP. SINTESI 12 The innovative pergola. Pergolas 06 Overview. Design characteristics 18 HELLA 22

Shading Tension Systems

HD 7/11-4 Cage Classic

Cold water compact class HD 5/11 C. Standard accessories: Trigger gun Extended highpressure. Technical data

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

Insect screens Effective, elegant and comfortable

Asymmetrical Products

SPECIFICATIONS. Pleated & Honeycomb MTM Blinds. Sec. : Pleated Date : Sep 2017 ISSUE: PB

External venetian blinds from Griesser. Lamisol

SISTEMA PROTAL.

HunterDouglas Roller Blind systems offer superior control with uncompromising quality and durability. From manual shades to fully automated systems,

Machine Protection Door

RIVERA P5000. Folding awning P5000

Cold water compact class HD 5/15 C

External Venetian Blinds

Hot water compact class HDS 5/12 C *AU

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage

Cord-operated curtain rails. elegant ease

External venetian blinds from Griesser. Metalunic

HD 5/12 C + Mobility. Accessory storage

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

Hakki Pilke Raven spare parts manual

HDS 6/14 C. Large tilting aid. eco!efficiency mode. Economical and environmentally friendly even during longer periods

External Roller Blinds Sun Control

Cold water compact class HD 5/17 C

HD 6/12-4 C. Pump technology. Automatic pressure cut-off. Extendable push handle. Accessory storage

CLASSIC WALL-MOUNTED PATIO HEATER

HD 6/15-4 Classic. Durable and robust. Improved cleaning performance. Especially easy to maintain. Excellent mobility

Cold water compact class Xpert HD 7125 *AU. Standard accessories: High-pressure hose 10 m Spray lance 380 mm Anti-twist system Pressure cut-off

Hot water super class HDS 12/18 4S *AU

Cold water compact class HD 5/12 C

With combustion engine HD 801 B. Equipment: Trigger gun Extended highpressure. Technical data

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

External venetian blinds from Griesser. Aluflex

Cold water compact class HD 5/17 C Plus

High performance door Albany RR3000 Series. ASSA ABLOY Entrance Systems

Hand-drawn curtain rails. wide channel

FREEDOM 2019.EX CZ - 21/11/18

innovative blinds for modern windows no holes, no screws, just style!

Trench Heating. Katherm NK

Plisé. Pleated blinds Plissee. DECOMATIC Premium quality / Made in Czech Republic. Interiér Interior Interieur. Váš dodavatel stínící techniky

CR20-07 A-F-A-E-HQQE 3x400/ HZ

Cold water compact class HD 6/13 C Plus *EU

Orbis Battery Scrubber OBS38130

CLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING

Internal sun shading systems Creative and flexible design comfortable living spaces.

HD 5/12 C Plus EASY! Mobility. Quality. Flexibility. Accessory storage

2018 Special-Lite ALUMINUM HARDWARE & LITES

Cold water compact class HD 6/15 CX Plus

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Cold water HD 9/18-4 ST

19 Cabinets. Eurolan. 19" Floor Standing Cabinets. Racknet Floor Standing Cabinets. Racklan Floor Standing Cabinets. Rackserv Floor Standing Cabinets

Trench Heating Katherm QK

With combustion engine HD 728 B Cage. Equipment: Trigger gun Extended highpressure. Technical data

KEMMLIT For every demand

Class Wind speed km/h Type 0-2,2 m 2,2-4 m

HDS 801 D. Mobile hot water high-pressure cleaner with comubstion engine for the universal use where no power supply is available.

Cold water compact class HD 5/12 C

ALUMINIUM VENITIAN BLINDS

Venetian Blinds. Solutions for Daylight Control

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

WE HELP PUSH THE BOUNDARIES AND CHALLENGE WHAT IS POSSIBLE

Technology and components for blinds. We start your innovations

Venetian Blind System

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Ceiling air diffuser INDULTHERM INDULTHERM-e

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

Architectural Blinds & Dynamic Solar Facades. No single factor has more environmental impact on a building than solar heat gain.

HDS 5/11 UX. Entry-level, highly portable hot water pressure cleaner with integrated hose reel. Integrated hose reel. Innovative upright design

SERIES: A REVISION ECN# DESCRIPTION OF CHANGE MOD. BY DATE 3 N/A DRAIN HOSE UPDATED 31/08/2016. Drawing Ref. No. Kit No. Part Description Qty

Soltec Product catalogue Sun protection with added value

R80. REFLEXA R80 EXTERNAL LOUVRE BLINDS External Aluminium Louvre Blinds for Sunshading over Glazed Surfaces

Hot water middle class HDS 7/10-4 M

CR A-F-A-E-HQQE 3x400/ HZ

Perimeos. Ceiling Recess. decor. systems

SPARE PARTS LIST - VTA 6S - 400V 50Hz 3~ Version 2.1

RA 701 B Batterie assembling. As at: 01/15/10 Time:21:19

Transcription:

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Experience the external venetian blind 80 S in action! www.warema.com/80s

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION The WAREMA external venetian blind with 80 mm beaded slat in standard version is the most popular external venetian blind on the market. However, also proven things should develop constantly and strive for perfection. The new WAREMA external venetian blind 80 S is the best example how this way of thinking can work. Proven details have been perfected and the product has been adapted to the current needs of the market.

EXPRESSIVE BUT STILL TIMELESS The new slat size of the 80 S with a reduced diameter of the beading increases the stability and strength of the slat. The guide nipple with high-grade 2 point welding and big counter plate transfers the stability through to the guide rails. The external venetian blinds have a dynamic and expressive effect in classic and timeless design.

DELICATE AND STILL STABLE The clearly reduced diameter of the beading sustainably reduces the slat stack height and ensures a more delicate look during view out. The new cable guide eyelet has a positive effect on the slat stack height and simultaneously facilitates a tilting angle as big as possible.

JUST MORE SHADING The optimised lift tape eyelets with the smallest outlet openings ensure minimised light points in the interior.

DISCREET AND HIGH-GRADE The optimised bottom rail is convincing due to its surface with constant stability. At the same time it captivates with its modern and timeless delicate design.

POSITIVE EFFECT ON THE ENERGY BALANCE Thanks to the new slat geometry and the optimised bottom rail the new WAREMA external venetian blind 80 S in standard design offers the smallest external venetian blind package on the market. The lower slat stack height has a positive effect on the energy balance of buildings in the case of shafts which are integrated into the facade. When using visible cover panels there is little influence on the facade view.

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Venetian blind facade system with beaded slats E 80 A2 S, E 80 A6 S, C 80 A2 S, C 80 A6 S External venetian blind E 80 A6 S External venetian blind C 80 A2 S 1 Top rail 2 Tilt shaft 3 Bearing 4 Slats 5 Tilting tape and lifting tape 6 Lateral guidance 6.1 Rail 6.2 Tension cable 7 Bottom rail

Application For mounting on transom and mullion facades or conservatories, in the reveal or in ventilated facades, in double skin facades, in front of the facade or indoors. Operation Motor The slats are raised and lowered as well as tilted by actuating an operating switch. Voltage: 230 V AC, other voltages optional Frequency: 50 Hz, other frequencies optional Degree of protection: IP 54 Plug connector: Hirschmann coupling The drive switches off upon reaching the upper or lower limit position using built-in, adjustable limit switches. Crank The slats are raised and lowered as well as tilted with the crank. Crank rod with collapsible crank; sealed joint plate and square with patented thermal separation. Material: Aluminium Surface: Crank holder: C0 anodised plastic, grey, white or brown, crank holder with magnet optional Top rail Material: aluminium, extruded Material thickness: 1.5 mm Dimensions (w x h): 59 x 51 mm Profile: C profile Surface: plain, optionally powder-coated or anodised Fixing: with noise-optimised top rail brackets made of plain aluminium. Tilt shaft Material: Galvanised steel Material thickness: 1 mm Dimensions (w x h): 12 x 12 mm Profile: Square tube Surface: plain Bearing Maintenance-free, enclosed Enclosure: plastic, with Teflon Tilting reel: Plastic Tape reel: Plastic Segment tilting to prevent self-acting adjustment of slats.

Slats on both sides optimally beaded with regard to slat stack height, curved Material: aluminium, special alloy Material thickness: approx. 0.44 mm Dimensions (W): 80 mm Installation: convex Surface: enamel finish resistant to corrosion Colour: using a special process according to WAREMA colour chart for external venetian blinds All cutouts in the slats have black protection eyelets, with an outlet size of 5 x 8 mm, to guide the lift tapes (reduction of wear) and fix the webs of the ladder tape. The blind moves down with the slats closed to the outside and moves up with the slats closed to the inside. Tilting tape and lifting tape Tilting tapes In special heavy-duty version with double cross ladders Material: polyester with Kevlar core Colour: black, optionally grey or white Each slat is fixed to the top web of the tilting tape and threaded through the double webs. Lifting tapes Material: Colour: Lateral guidance Rail A6 polyester, with special coating black, optionally grey or white With black sealing strips inserted for noise reduction Material: aluminium, extruded Dimensions (w x d): 25 x 18 mm, optionally other rail variants Profile: C profile Surface: powder-coated, optionally anodised Fixing: 2-piece guide rail bracket H1, aluminium and plastic End cap: plastic, black, optionally grey or white Sealing strip: weather-proof, UV stable, black Guiding nipple: Polyamide, glass fibre reinforced, impact-resistant connection with the slats, alternatively nippled

Tension cable - A2 Strand wire Material: Steel, resistant to corrosion Coating: polyamide Dimensions (Ø): 3.3 mm Colour: black or transparent coating Fixing: tension cable bracket S01, aluminium The cable guides are fixed with a special spring tension device to compensate for thermal changes in the length of the top rail. Cable guidings run trough oblong holes in the slats and the bottom rail. They are fixed to the window or the wall using tension cable brackets. Colours Powder coating of aluminium parts with chrome-free pre-treatment according to valid RAL CLASSIC colour chart (except camouflage and luminous colours) or in six DB colours as well as eight textured colours (W4914 - W4921), four anodized-look colours (WC31 - WC34) and further colours according to WAREMA standard colour fan (in WAREMA colour specification). Other colour specifications and special colours are available upon request and at a surcharge. Bottom rail With end caps Material: aluminium, extruded Dimensions (w x h): 80 x 15 mm Surface: powder-coated, optionally anodised End caps: plastic, black Bottom rail for rail guidance A6 with sliding guiding nipples with slotted end caps to prevent the external venetian blind from unhinging.

Construction limit values/measuring instructions Venetian blind facade system Beaded slats with cable or rail guidance Construction limit values in mm For external venetian blinds with equipment variant vivamatic (VM), slowturn (ST) or work setting (AS) the construction limit values of the corresponding basic type should be assumed. Max. 3 curtains are possible here as a coupled unit with one drive. Construction limit values Individual unit Coupled units left/right of driving curtain average weight Types Width 2) Surface 3) Surface 3) max. coupl. each side in kg/m 2 1) Height max. width in m 2 in m 2 Surface in Number of min. 4) max. m 2 curtains C 80 A2 S 4000 450 5000 C 80 A6 S 5000 12 12000 12 12 2 2.7/2.8 E 80 A2 S 4000 20 600 5000 E 80 A6 S 5000 25 12000 26-30 13 2 3.0/3.1 1) Cable force: 450 N per tension cable. 2) Width = slat size, slat size + 65 mm = back edge of the guide rail for FSCH types 1 and 2. 3) The maximum surfaces indicated depend on the height in each case. 4) Sloped running of the slats cannot be prevented for small widths.

Cover panel height Recess height Clear shading height approx. 15 Slat stack height 7 Cover panel depth 32 80 Recess width External venetian blind height 12 (19 for AS) Measuring instructions Slat stack height from the table Slat stack height with work setting (AS) + 7 mm Recess height = slat stack height + 15 mm Cover panel height = slat stack height + 20 mm Types Min. recess width Number of guide cables for 80 A2 S Cover panel depth min. 80 A2 S/A6 S 120 130 Order width Cable guidances less than 3 m 2 from 3 m 3 from 4 m to 5 m 4 When ordering, please indicate positioning of additional cable guiding (starting inside from the left)! For model A6 we recommend an additional cable guide at the centre of the blind for external venetian blind widths > 3000 mm. Measuring instructions external venetian blinds C/E 80 A2 S/A6 S

Slat stack heights in mm Slat stack height determined using external venetian blind height Types E 80 A2 S / E 80 A6 S External venetian blind height in mm 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 Slat stack height determined using clear shading height Types E 80 A2 S / E 80 A6 S Clear shading height in mm 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 159 169 180 191 201 212 222 233 243 254 264 275 285 296 306 317 327 338 348 Slat stack heights are approximate values. For technical reasons, they might be higher or lower. External venetian blinds with crank drive: Slat stack height is reduced by 20 mm. External venetian blinds with work setting: Stack 7 mm higher, top rail support Art. No. 551012

Construction limit values for venetian blind window system, top-mounted external venetian blinds for new buildings as well as front-mounted external venetian blinds in mm Types Cover panel / Box height Venetian blind window system 1-4 Width Individual units Height Order height without stack protrusion in mm approx. protrusion Surface per 100 mm additional height in in m² mm min. max. max. max. max. max. E 80 A6 S 230 2200 E 80 A6 S 260 680 4000 4000 2800 E 80 A6 S 300 3600 Top-mounted external venetian blinds for new buildings Combination Width Surface in m² Number of curtains 5 16 4000 16 3 E 80 A6 S 300 680 4000 4000 3500 5 16 4000 16 3 Front-mounted external venetian blinds R6 without insect screen E 80 A6 S 16.5 2600 680 4000 4000 E 80 A6 S 18.5 3000 R10 without insect screen E 80 A6 S 16.5 2600 680 4000 4000 E 80 A6 S 18.5 3000 R10 with insect screen E 80 A6 S 16.5 2100 710 2000 2500 E 80 A6 S 18.5 2500 5 16 6000 24 3 5 16 6000 24 3 5 5 6000 15 3

Venetian blind facade system Beaded slats with cable guidance E 80 A2 S with angular cover panel Cover panel length 12 Slat size - order dimension 12 Foam sealing strip as part of mounting on-site 100 See table for further breakdown 100 20 Mounting bracket 20

DIN 7985-A2 M5x8 Bracket Foam sealing strip as part of mounting on-site Device connection socket Wisotronic min. 10 approx. 20 External venetian blind height 12 Cover panel height approx. 15 Slat stack height 7 Tension cable bracket 80 min. 130 min. 60 H05 RR-F 4G 0.75SW DIN 7976-A2 C6.3x38 with seal coating DIN 9021-A2 A6.4 DIN 7976-A2 C6.3x38 with seal coating DIN 125-A2 A6.4 230V, 50Hz, 10A NYM-J 4x1.5mm² Push button

Venetian blind facade system Beaded slats with rail guidance E 80 A6 S with U-shaped cover panel at transom and mullion facade Cover panel length 10 Cover panel length 12.5 Order dimension Order dimension 12.5 12.5 Axial dimension Axial dimension 12.5 20 Slat size 65 Slat size 20 100 See table for further breakdown 100 100 See table for 100 further breakdown Cover panel console, edge situation Joint connector, spot-welded Cover panel console, centre situation Mounting bracket

Guide rail length 50 prox. 20 External venetian blind height 12 Cover panel height approx. 15 Slat stack height 7 Guide rail bracket Guide rail 80 140 Bracket min. 20 Cover panel console, edge/middle 90 125 H05 RR-F 4G 0.75SW Threaded bolt M8 and Drilled hole Ø13 on-site EPDM sealing washer, WAREMA stop nut M8-A2, washer DIN 9021-A2 A8.4 nut DIN 934-A2 M8 Device connection socket 230V, 50Hz, 10A NYM-J 4x1.5mm² Push button

Venetian blind facade system Beaded slats with rail guidance C 80 A6 S with angular cover panel 12 Order dimension 12 32.5 Slat size 32.5 100 See table for further breakdown 100 Foam sealing strip as part of mounting on-site Gear Mounting bracket

DIN 7985-A2 M5x8 Bracket Foam sealing strip as part of mounting on-site 50 Guide rail length approx. 20 External venetian blind height 12 min. 10 Cover panel height approx. 15 Slat stack height 7 DIN 7976-A2 C6.3x38 with seal coating DIN 9021-A2 A6.4 Guide rail bracket Guide rail 33 45 80 min. 130 min. 60 ø16 on site ø16 DIN 7976-A2 C6.3x38 with seal coating DIN 9021-A2 A6.4 DIN 7983 C4.2x13 Pivot bearing 35-54 Crank rod Crank holder Collapsible crank

Venetian blind facade system Beaded slats with rail and cable guidance E 80 A2 S/ A6 S with angular cover panel - corner position Cover panel length Max. order dimension 2400 Foam sealing strip as part of mounting on-site Slat size Mounting bracket See table for further breakdown 150 32.5 12 A A

Bracket Foam sealing strip as part of mounting on-site 12 7 80 min. 130 min. 65 A-A min. 10 H05 RR-F 4G 0.75SW Device connection socket approx. 20 External venetian blind height Cover panel height Slat stack height 45 approx. 15 230V, 50Hz, 10A NYM-J 4x1.5mm² Push button

Self-supporting external venetian blinds Cover panel mounting between the guide rails E 80 A6 S with round-shaped cover panel on transom and mullion facade 30 45.5 100 Axial dimension = order dimension Cover panel length Slat size 60 Axial dimension = order dimension See table for further breakdown 100 100 45.5 45.5 Cover panel length Slat size Guide rail Ø52 Angle bracket Plug-in grommet STM 32 Holding profile for cover panel Bracket Mounting bracket

1) (45) End cap Bracket 1) H05 RR-F 4G 0.75SW Device connection socket 37 Cover panel height 1) for external venetian blinds with work setting NYM-J 4x1.5mm² Guide rail length External venetian blind height 80 Threaded bolt M8 and Drilled hole Ø13 on-site EPDM sealing washer, WAREMA stop nut M8-A2, washer DIN 9021-A2 A8.4 nut DIN 934-A2 M8 Push button Guide rail bracket Guide rail min. 90 25 30 Slat stack height 25 230V, 50Hz, 10A approx. 15

Self-supporting external venetian blinds Cover panel mounting on the guide rails E 80 A6 S with U-shaped cover panel at transom and mullion facade 12.5 5 32.5 100 Cover panel length Order dimension Axial dimension Slat size See table for further breakdown 100 100 32.5 10 32.5 Cover panel length Order dimension Axial dimension Slat size Guide rail 25x50 Angle bracket Plug-in grommet STM 32 Underlapping console Holding profile for cover panel Bracket Mounting bracket

1 Guide rail length 40 External venetian blind height 13 (19) Cover panel height 1) Bracket 150 32 1) for external venetian blinds with work setting Push button Guide rail bracket Guide rail min. 90 Threaded bolt M8 and Drilled hole Ø13 on-site EPDM sealing washer, WAREMA stop nut M8-A2, washer DIN 9021-A2 A8.4 nut DIN 934-A2 M8 30 approx. 15 Slat stack height 7 H05 RR-F 4G 0.75SW Device connection socket 230V, 50Hz, 10A NYM-J 4x1.5mm²

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

111910en/01.2014 Art. No. 877693