Options & Limitations Venetians - Micro, Slimline & 50mm Classic 16mm MICRO 25mm SLIMLINE/ MAGNAVIEW 25mm TWI-NIGHTER 50mm CLASSIC MAXIMUM WITH 3100mm 3700mm 3700mm 4000mm MINIMUM WITH (See price book for operation details) 110mm 110mm 110mm 160mm MAXIMUM ROP 3700mm 3700mm 3700mm 3500mm MAXIMUM AREA 7m² 9m² 9m² 12m² MAXIMUM TAPE SPACING MAXIMUM EN ROUT ISTANCE 400mm 600mm 600mm 900mm 114mm 152mm 152mm 152mm TAPE PITCH 12mm 20mm 18mm 41mm SLAT OVERLAP 4mm 5mm 50mm 9mm MINIMUM RECESS EPTH FULLY RECESSE BOX MOUNT SHAE STACK HEIGHT 20mm 20mm N/A 20mm (must side fix or back fix) 50mm 50mm N/A 90mm.042 x drop + 45mm.034 x drop + 45mm.036 x drop + 45mm.05 x drop + 80mm NUMBER OF SLATS ROP - 45 12 ROP - 45 12 ROP - 45 18 ROP - 70 41 STANAR WAN SIZES 500mm / 750mm / 1000mm / 1500mm Cord Control 500mm/750mm 1000mm/1500mm Worm & Gear SLAT THICKNESS.195mm (unpainted).215mm (coated).195mm (unpainted).215mm (coated).175mm (unpainted).215mm (coated) HEA CHANNEL 25mm Wide 25mm High 25mm Wide 25mm High 25mm Wide 25mm High 57mm Wide 51mm High Available with the UO-FLEX option Yes Yes Yes Yes SLAT = High Tensile # 6011 Aluminium Alloy. PAINT = Thermosetting Polymer Coating over a Chromated Primer. Comforming to AS2728. REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 2 OF 15
Aluminium Venetians Special Shapes 16mm and 25mm SLAT ONLY. NO SPECIAL SHAPES ONLY CUT OUTS AVAILABLE ON LIMITE EITION OR 50mm Venetian Blinds.. Note: Cord control side must be on shortest side of blind, as indicated by an X. Unless otherwise indicated, blinds will tilt and raise. Blinds will only raise as far as the shortest side. Shape w A W X W A A A W SMALL CUT OUT Limitations A < 149mm (25mm slat) A < 114mm (16mm slat) AIR CONITIONING CUT OUT A > 150mm (25mm slat) A > 115mm (16mm slat) CENTRE CUT OUT HEARAIL CUT BACK A must be > 90mm Tilt Only A < 180mm (25mm slat) A < 150mm (16mm slat) How to Price Blind Price (W x ) + small Cut Out surcharge Blind Price (W x ) + air conditioning surcharge Blind Price (W x ) + air conditioning surcharge Blind Price (W x ) + small Cut Out surcharge Shape W Up to 45º X X Up to 45º X W X Up to 45º SLOPING BOTTOM SLOPING HEA SLOPING HEA & BOTTOM HALF SLOPING BOTTOM (Tilt Operation Only) How to Price Blind Price (W x ) + Sloping surcharge W Blind Price (W x ) + Sloping surcharge Up to 45º Blind Price (W x ) + Sloping surcharge The Following Shapes Are Not Available Blind Price (W x ) + Sloping surcharge Up to 45º A CIRCLE A > 180mm (25mm slat) A > 150mm (16mm slat) HEARAIL SHORTER THAN BOTTOM RAIL TRIANGLES ARCH REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 3 OF 15
Aluminium Venetian Blind Measuring For 25/25 Headbox using Spring Loaded Mounting Brackets & End Plugs REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 4 OF 15
Aluminium Venetian Blind Measuring 50mm Classic Aluminium Venetians - Spring Loaded Brackets WITH -0 WITH +50 60mm WITH -10 ROP -10 TO SILL -10 ARCH -10 TO FLOOR -10 WITH -10 ROP -10 +120 ARCHITRAVE & REVEAL FACE & REVEAL WITH -10 FRONT EGE +50 ON FACE CORNERS WITH -5 WITH -60 FRONT EGE -10 WITH -65 BAYS WITH -60 WITH -30 FRONT EGE -5 WITH -30 FRONT EGE -0 ON FACE WITH -60 FRONT EGE -5 WITH -30 WITH -30 REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 5 OF 15
ALUMINIUM VENETIAN BLINS INSTALLATION OPERATION AN CARE INSTRUCTIONS IMPORTANT: Please read these instructions all the way through before installing. MATERIAL AN TOOLS Each Venetian Blind ordered should include: Spring loaded mounting brackets (No. depends on size) 2 hold-down brackets 2 screws for each bracket (20mm x 6# Panhead) 2 cord cleats and screws TOOLS REQUIRE Steel measuring tape Carpenter s level Power or battery drill and bits Flat blade and Phillips head screwdrivers Scissors 16MM & 25MM ALUMINIUM VENETIANS MOUNTING THE BRACKET The installation brackets may be Reveal (inside the window frame) or Face (outside the window frame) mounted. In all cases, level mounting is critical to the operation of the blind (use Carpenter s level). SPRING LOAE REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 6 OF 15
REVEAL FIT (INSIE MOUNT) Hold the Venetian inside window frame and mark position of brackets so as not to foul tape drums. Attach the brackets with screws provided, (1 per bracket for top fix), to the front of the reveal, ensuring the front edges are in line and level. This is the usual position, however you may want to fit them further back into the reveal. NOTE: May need to use washers or packing to ensure level. FACE FIT (OUTSIE MOUNT) Hold the Venetian on the face of the window and mark position of brackets, so as not to foul tape drums. Attach the brackets with screws provided (2 per bracket for face fit) ensuring all brackets are in line and level. NOTE: Blind will close tighter if fitted level. If headbox bows poor closure will result. CONTROL EN BRACKET LOCATION TILT AN LIFT SAME EN TILT AN LIFT OPPOSITE EN 16mm 80mm from end of headrail 55mm from end of headrail 25mm to centre of bracket. to centre of bracket. TILTER & CORLOCK TAPE RUM SUPPORTS MOUNTING BRACKETS 80MM 80mm Intermediate brackets should be spaced evenly and as close to tape drum supports as practical. FACE FIXING ONTO CEMENT RENERE WALLS o not drill too close to edge as render may break away. Use suitable rawl plugs in conjunction with the screws supplied. FIXE TO CLEAR HANLES ETC If needing to pack out from window to clear handles, locks etc use a full width piece of timber as this is more stable than individual pieces and you are able to fix brackets to timber in any position. REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 7 OF 15
INSTALLING THE BLIN Simply slip the headrail onto the front hooks of the bracket, push inwards and twist the back of the headrail upwards in one motion. The headrail will snap into position. InSTall The blind 2 1 SIde guiding HOL OWN BRACKETS (OPTIONAL) Hold-down Brackets are used to keep the bottom of the blind from swaying in the breeze. They may be Reveal (inside the window frame) or Face (outside the window frame) mounted. With the blind fully lowered, place the hold-down brackets onto the pins of the bottom rail and mark the hole locations. Attach the bracket with screw/s supplied (20mm x 6# Panhead). Place the bottom rail into the brackets, open and close the blind. 01-F0636.0 NOTE: The drop ordered on a venetian blind is measured in the closed position from the top of the headrail to the lowest position on the bottom rail. EN MOUNTING BRACKETS (OPTIONAL) These brackets are used in lieu of the spring mounting brackets. Fixing Instructions: Add 10mm to the headrail size, this gives you the position to fit the outside edges of the end mounting brackets. End mounting brackets can be screwed through the top, back or side as indicated. Brackets are marked left or right. Use 2 Panhead 20 X 6 screws per bracket. If swivel brackets are required, locate evenly along the headrail ensuring not to foul the tape roll supports. Fixing the Blind: Insert slide into the bracket which will be closest to the tilter and cordlock. Insert headrail into end mounting brackets, then fit remaining slide. If using swivel brackets to support the centre of the blind, ensure lever is fully out as indicated in the diagram. After the headrail has been locked into position by end mount brackets, close lever on swivel brackets to lock into place (see arrow). UNIWAN These brackets are used in lieu of Uniwand. Uniwand mechanism is suitable for 25mm and 16mm venetains only. By moving the uniwand lever up and down the slats are raised or lowered to the desired position. These brackets help keep the headrail fixed while under tension when operating the blind. REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 8 OF 15
REMOVAL OF THE BLIN To remove, open slats and raise the blind. If the blind has three or more brackets, remove the headrail from both ends first, leaving the centre bracket to last. Push the headrail in and twist down at the back of the headrail to release the headbox from the hooks at the back. Leave the headbox hanging on the front hooks. Repeat at each bracket, then lift the blind from the bracket and take down. WAN TILT CLUTCH (OPTIONAL) MounTIng The brackets To protect your blind from overwinding, some Aluminium Venetian Blinds come with a clutch in the top of the wand. When too much pressure is applied the teeth of the clutch skip over each other to prevent damage. OPERATION - 16 & 25MM VENETIAN WAN TILT: simply rotate the wand to tilt the slats from fully closed to any desired angle. 25MM LITERISE SPACER BLOCK When installing LiteRise, spacer blocks are needed to be fixed for a face fix installing. optional SpaCer block RAISING & LOWERING OF BLIN: to raise, tilt the slats to the fully opened position. Remove the bottom rail from the own brackets (if fitted). Pull the lift cord towards the centre and raise the blind. To lock in position simply move the cord towards the outer edge of the blind to engage the cord lock. To lower, simply pull the cord towards the centre of the blind and lower gently. 01-F0432.0 REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 9 OF 15
OPERATION - UO-FLEX OPERATING SYSTEM UO-FLEX OPERATING SYSTEM RAISING & LOWERING OF THE BLIN: 1. Lower the blinds. CARE AN CLEANING 1. ust can be easily brushed off at regular intervals using a clean soft cloth, a feather duster, or a vacuum cleaner with brush attachment. 2. To dust, tilt the slats up and then down (but not entirely closed) to reach the entire top and bottom surfaces. 3. To vacuum, use the brush attachment and tilt slats as per point 2 above. 4. Slats may be wiped over with warm water and a mild detergent. 2. Twist the wand to operate the opening and closing of the slats. 3. Twist the wand to the right to close all of the slats. 4. Twist the wand to the left to vary the opening of the slats. 5. If a different closing height or other blind desired, repeat steps 2 to 4. REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 10 OF 15
50MM ALUMINIUM VENETIANS MOUNTING THE BRACKET The installation brackets may be Reveal (inside the window frame) or Face (outside the window frame) mounted. In all cases, level mounting is critical to the operation of the blind (use Carpenter s level). REVEAL FIT BRACKET FACE FIT BRACKET REVEAL FIT (INSIE MOUNT) Hold the Venetian inside window frame and mark position of brackets so as not to foul tape drums. Attach the brackets with screws provided, (1 per bracket for top fix), to the front of the reveal, ensuring the front edges are in line and level. This is the usual position, however you may want to fit them further back into the reveal. NOTE: May need to use washers or packing to ensure level. FACE FIT (OUTSIE MOUNT) Hold the Venetian on the face of the window and mark position of brackets, so as not to foul tape drums. Attach the brackets with screws provided (2 per bracket for face fit) ensuring all brackets are in line and level. NOTE: Blind will close tighter if fitted level. If headbox bows poor closure will result. FACE FIXING ONTO CEMENT RENERE WALLS o not drill too close to edge as render may break away. Use suitable rawl plugs in conjunction with the screws supplied. FIXE TO CLEAR HANLES ETC If needing to pack out from window to clear handles, locks etc use a full width piece of timber as this is more stable than individual pieces and you are able to fix brackets to timber in any position. REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 11 OF 15
INSTALLING THE BLIN Simply slip the headrail onto the front hooks of the bracket, push inwards and twist the back of the headrail upwards in one motion. The headrail will snap into position. HOL OWN BRACKETS Hold-down Brackets are used to keep the bottom of the blind from swaying when mounted on doors or exposed to the wind. The hold-down brackets are inside or outside mounted at the bottom of the window opening. With the blind fully lowered, place the hold-down brackets on to the pins on the end of the bottom rail and mark mounting hole locations. Attach hold-down brackets with screws provided. With the bottom rail attached to the hold-down brackets, the slats may be opened or closed. isconnect the rail from the brackets to raise and lower the blind. PROTECTING YOUR CHILREN Please be aware that blind cords or chains pose a strangulation hazard for children. To reduce the risk of strangulation this internal window covering must be installed in such a way that a loose cord cannot form a loop 220 mm or longer at a height of less than 1600mm above floor level. Your blind is provided with a cord cleat. It is essential that the following installation instructions are adhered to: If a cleat is used to secure the cord, it must be at least 1600mm above floor level to \ prevent children from unwinding the cord from the cleat. SAFETY EVICES This pack includes the following child safety devices: Safety Cleat Pack 26.228.000 Hold own Pin 26.165.000 End Cap ECI 26.167.XXX Hold own Bracket 26.154.030 NOTE: These safety devices MUST be installed and used. Ensure the bottomrail of your blind is secured into the hold down bracket while the blind is in the down position. CHIL SAFETY INSTALLATION INSTRUCTIONS Be aware that it is possible for children to strangle in window covering cords. To reduce the possibility of such an accident, all cords must be kept out of the reach of children, including infants. Cord cleats are an effective way to implement this essential precaution. REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 12 OF 15
INSTALL COR CLEATS Attach the cord cleats 153mm to 305mm apart at a height at least 1600mm above floor level to prevent children from unwinding the cord from the cleat. Take into account that a child may stand on a baby cot or other furniture in an attempt to reach the cords. Once the cleats are attached, simply wrap the excess cord around them after each use of the shade, as shown. Cord Cleat OPERATION - 50MM SLAT COR TILT: Pulling on one of the single cords will tilt the slats in one direction, and pulling the other cord will tilt the slats in the opposite direction. RAISING & LOWERING OF BLIN: to raise, tilt the slats to the fully opened position. Remove the bottom rail from the hold-down brackets (if fitted). Pull the lift cord towards the centre and raise the blind. To lock in position simply move the cord towards the outer edge of the blind to engage the cord lock. To lower, simply pull the cord towards the centre of the blind and lower gently. CARE AN CLEANING 1. ust can be easily brushed off at regular intervals using a clean soft cloth, a feather duster, or a vacuum cleaner with brush attachment. 2. To dust, tilt the slats up and then down (but not entirely closed) to reach the entire top and bottom surfaces. 3. To vacuum, use the brush attachment and tilt slats as per point 2 above. 4. Slats may be wiped over with warm water and a mild detergent. REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 13 OF 15
Calculation of Length Of Slider Shaft Shaft Travelling Groove A X Y X Lever B 5cm Formula for calculation of length of shaft If height B is greater than 200cm X= A/2+B-180cm Y= A/2 If height B is less than 200cm X=A/2+150cm Y=A/2 Note: We require 2 height measurements to produce an order: Height: A height of blind Height B height from top of blind to floor Height X height of shaft (Minimum 300m/Maximum 300m) Table showing shaft lengths of blinds of different heights B Height from top of blinds to floor A Height of blinds Sizes cm 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 150 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 155 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 160 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 165 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 170 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 175 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 180 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 185 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 190 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 195 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 200 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 205 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 210 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 215 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 220 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 225 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 230 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 235 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 240 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 245 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 250 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 14 OF 15
Adding innovation and Child Safe Solutions to our timeless design The Hunter ouglas product range is continuously improving and innovative products are always being added. With the introduction of Light Lift operation to the Aluminium Venetians Collection, raising, lowering and tilting is now easier than ever. With the new modern handle, simply push up to raise the blind and down to lower. Using the same motion you can tilt the slats to any required position. This is controlled by advanced motor gears and high quality spring mechanisms specifically designed for effortless and precise operation. The handle is available in black, white and silver for easy colour coordination with the 25mm slat range. We understand the importance of safety in commercial applications. The patented Light Lift design eliminates the cords providing a significant increase in safety for children and pets whilst creating a clean, uncluttered look. Available in 25mm Slimline and Limited Edition Light Lift size limitations: 3.6sqm, width 2000mm, drop 2000mm REPLACES ISSUE ATE: APRIL 2015 APPROVE BY: R. BOKTOR PAGE 15 OF 15