DAYLIGHTING PERFORMANCE ON VENETIAN BLIND FOR HEALTHY APARTMENT HOUSING

Similar documents
Windows Influence on Room Daylighting in Residential Buildings

POTENTIAL ENERGY SAVINGS WITH EXTERIOR SHADES IN LARGE OFFICE BUILDINGS AND THE IMPACT OF DISCOMFORT GLARE. Sabine Hoffmann, Eleanor Lee

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Buidling 661 Annual Daylight Performance Modeling Studies

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Annual environmental performance evaluation of light and heat in daylight harvesting systems using Radiance and NewHASP

External venetian blinds sunlight included 40% ENERGY SAVINGS WITH INTELLIGENT SUN SHADING

THE GLARE EVALUATION METHOD FOR CIVIL AIRPLANE FLIGHT DECK

COOLING ENERGY SAVING SYSTEM USING A WATER MIST DEVICE ON WINDOWS

NRG SYSTEMS, HINESBURG, VT

Adelaide Homes Design Guide 3 - Shading

Daylight and Whole-Building Energy Analysis Using Radiance in IES <Virtual Environment>

Discomfort glare with complex fenestration systems and the impact on energy use when using daylighting control

CLASSIFICATION AND EXPERIMENTATION FOR THE DEVELOPMENT OF DAYLIGHTING SYSTEMS IN COLD AND SNOWY REGIONS

R80. REFLEXA R80 EXTERNAL LOUVRE BLINDS External Aluminium Louvre Blinds for Sunshading over Glazed Surfaces

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

A Study on Cooling Rate with Blade and Sound Fire Extinguisher

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

13-15, 2001 USING LIGHTING SIMULATION TO ASSESS THE PERFORMANCE OF AND INDIRECT OFFICE LIGHTING SYSTEMS IN DYNAMIC WORKPLACES

English Version. Daylight of buildings

Development of a Slope Stability Program for Transmission Towers

Cardinal Coated Glass Superior glass products for residential windows and doors G L A R E C O N T R O L G L A S S

Study on the Effects of Learning by Changing the Color- Temperature LED Lamp

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

EFFECTS OF COMBINING SMART SHADING AND VENTILATION ON THERMAL COMFORT

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

Performance Analysis of Water-Water Heat Pump System of 100 kw Scale for Cooling Agricultural Facilities

Intelligent Sun Control

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

Upward Evacuation Experiment for Estimating Evacuation Speed in Water Disaster

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

The Influence of the Courtyard Geometry on the Passive Lighting Energy Savings Jie TAN 1,* Xin GUO 2 and Ming-ping ZHANG 1

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Connect North and South Korean Separated Families Higher Comfort Lower Energy

Visual analysis on the nightscape lighting for the pedestrian and greenery zone of a neighborhood park

THE EFFECT OF ARCHITECTURAL DETAILS ON DAYLIGHT DISTRIBUTION INSIDE A ROOM

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

An experimental study of the impact of tunnel suppression on tunnel ventilation

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

Variable Light and Shade. Flexible sun and glare protection systems

A STUDY ON THE APPLICABILITY OF THE TIME-DIVISION HOT-WATER SUPPLY HEATING FOR ONDOL - THE RADIANT FLOOR HEATING SYSTEM IN KOREA

Optimizing the Radiance Workflow: In an Integrated Firm Environment

A Study on Power Consumption of Household Appliances for Life Conduct Activity of Single Household in University Town

Guidelines for sizing roof windows

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Indoor Moisture Control of Auckland Houses with Different Ventilation Systems

Daylight at home: differences between developers and architectural competition houses

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Design with nature: integrating green façades into sustainable buildings with reference to Abu Dhabi

A study of radiant cooling for a room with daytime application in tropical climate

Development of Smart Phone Applications Linked with Fire Alarm Control Panel in Automatic Fire Detection System

Window Management Strategies for Energy Conservation Leader Primer Series, Number 1 1

HunterDouglas Silhouette Shades are unique and extremely versatile window shades; soft as silk, elegant as a curtain and practical as a venetian

Hot Air-Microwave Combined Drying Characteristics of Gypsum Board. Won-Pyo Chun, Sung-Il Kim, and Ki-Woo Lee 1

INTERNATIONAL JOURNAL OF RESEARCH GRANTHAALAYAH A knowledge Repository

Passive Indirect Evaporative Cooler

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Heat Transfer in Evacuated Tubular Solar Collectors

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

- Murdoch University, Western Australia.

Experimental Study and Analysis of Flat Plate Solar Water Heater with Different Flow Rates using of Circulating Pump

Transition of soil strength during suction pile retrieval

ISO 9050 INTERNATIONAL STANDARD

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

Asian Journal on Energy and Environment

Adelaide Homes Design Guide 4 - Winter warming

ENVIRONMENTAL STRATEGY FOR ROW HOUSE- CAPE TOWN

ENERGY EFFICIENCY BRIEF REPORT

PCM-module to improve hot water heat stores with stratification: first tests in a complete solar system

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Smart Green Roofs: Cooling with variable insulation

Advanced Lighting For Office

VENTAL V80 EXTERNAL LOUVRE BLINDS External Aluminium Louvre Blinds for Sunshading through Glazed Surfaces V80

Modified geotextile tube a new geotextile tube for optimized retaining efficiency and dewatering rate

Optimal control for superior lighting performance

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

Itaru TAKAHASHI Ph.D 1 Akihiko KUROIWA 2

Solar Thermal Planning Worksheet Date: / /

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Effect of Placement of Footing on Stability of Slope

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

HOUSING Energy saving for windows

Lighting Application Guide for K-12 Classrooms

Energy Performance of a Desiccant and Evaporative Cooling-assisted Airconditioning System under Various Climatic Conditions in China

nzeb office building

HEATSTRIP COSY WARMTH

IP65 High Bay Dual Sense Sensor

A Study on Hierarchy of Spatial Configuration in Outpatient Department of General Hospital

[Patil* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Daylighting Control Design and Application Guide

Lighting Design Criteria: Codes and Standards

Intigral Innovia 750 Lift & Tilt Blinds (3/4 Air Space) TB

Transcription:

Paper s No. BUE-FISC2010 154 DAYLIGHTING PERFORMANCE ON VENETIAN BLIND FOR HEALTHY APARTMENT HOUSING Hwa Young Shin 1 / Yeunsook Lee 2 / Mi Seon Jang 2 / Ki Hoon Moon 3 / Jeong Tai Kim 1 * 1 Kyung Hee University / 2 Yonsei University / 3 KSCFC Technology Educational Institute shinhy@khu.ac.kr / yeunsooklee@yonsei.ac.kr / graypea78@naver.com / khmoon@kscfc.co.kr / jtkim@khu.ac.kr* (Corresponding author) ABSTRACT: The balcony expansion of apartment houses has been legalized recently in Korea and causes lots of environmental problems. Enlarging living area by balcony expansion, the unshaded window area is exposed to the direct sunlight. Blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting slat angle and blind height. However, blind system can produce discomfort in occupant and less energyefficiency, if it has not been controlled optimally. The purpose of this study was to estimate the occupant preferred position method for daylight control and recommended the operation of venetian blinds. The main variables related to ratio of shading height to window area and blind s slat angle to seasonal variation and solar positions. The room dimensions based on unit module of apartments are 6.0m(width) X 6.9m(depth) X 2.7m(height) with 4.5m X 2.43m window opening. The blind system was simulated at five slat angles (horizontal, 30, 45 upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, non-blind) using the Desktop RADIANCE 2.0 program. The simulation results show as two indicators: daylight illuminance and uniformity. Conference Topic: The Earth/Desert/Green and Sustainable Buildings Keywords: Venetian blind, Solar control, RADIANCE program, Daylighting performance 1. INTRODUCTION: In Korea, floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. A balcony as a buffer space plays an important role in overhang sturucture, climate filter, and indoor noise environment. Eliminating the balcony, the larger glass area of window in living space have produced excessive penetration of direct sunbeams and uncomfortable glare. In addition, occupants might be exposed to unwanted UV ray which cause a critical risk to their

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND Shin, H. Y., Lee, Y., Jang, M. S., FOR HEALTHY APARTMENT HOUSING Moon, K. H., Kim, J. T. health. Thus, using a proper controlled daylighting strategy is a key factor for creates a high quality indoor environment and control energy demands. As a common sunlight controlling device, venetian blind system is essential to not only excluding intense daylight and reflecting light to rear wall zone but also improving uniformity in illuminance. In the preliminary stage of the study, parametric analysis on daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles. A series of simulation produced illuminance data for the internal lighting level. 2. RESEARCH DESIGN AND METHOD: 2.1 Simulation Model For the comparative study of daylight conditions, the CIE Clear sky applied to simulation model that considered as direct sunlight and installed on the south-facing window in general apartment building in Korea. In this study, conventional type of a horizontal blind was used to produce the Table 2. Korean standards A 3011: recommended level of illuminance in apartment basic performance data by Radiance program. The parametrical case studies of three cases of shading height to window area and five tiled slat angles were simulated to seasonal variation (equinox, summer, winter). Table.1 Radiance simulation parameters Parameters Building Type Simulation Model Window Sky Condition Orientation Simulation Period Glazing Transmittance Reflectance Blind Control Contents Typical apartment house 6.0m(W) X 6.9m(D) X 2.7m(H) 4.50m(W) X 2.43m(H) CIE clear sky South March, June, December, 21 (noon) 78.2% (Clear LBNL) Floor 30.0% (grey LESO91) Ceiling 71.0% (beige paint LBNL) Wall 59.5% (beige LESO91) Frame 58.7% (light blue LES091) Blind 71.0% (beige paint LBNL) Shading Height 0%(no-blind), 30%, 60%, 100%(fully-closed) Slat Angles -30-45 0 +30 +45 Slat Width 40mm 2

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND Shin, H. Y., Lee, Y., Jang, M. S., FOR HEALTHY APARTMENT HOUSING Moon, K. H., Kim, J. T. Fig 1. Model configuration Fig 2. Blind control (slat angle and shading height) The room dimension was 6m X 6.9m (width by depth) and a floor to ceiling height of 2.5m(Fig. 1). Typical apartment building in Korea has a prototype of a window system with pair glass with a 78% transmittance. The internal walls are covered with a beige wall paper with a reflectance of 59.5%. The ceiling consists of a beige paper with a reflectance of 71% and the floor is covered with a gray carpet with a reflectance of 30%. Table 1 and Figure 2 show the simulation conditions and control method of blind system applied to Radiance analysis. 2.1 Criteria of Dayligting Performance To providing daylighting parametric data related to shading height and slat angles, illuminance(lux) and uniformity value were calculated. A total of 81 illuminance sensors were located at 0.45m above the floor and spaced at a 0.5m interval starting from the surface of the interior wall as shown in Figure 1. The uniformity(u) can be defined as the ratio of the minimum to average illuminance. By providing enough daylight for the perimeter zone, not only electric lighting but also cooling demand can be reduced. The threshold value of illuminance can vary according to the task category. Table 2 is a list of a Korean Standards illuminance recommendation that intended to guide an appropriate illuminanace for apartment. Table 2. Korean standards A 3011: recommended level of illuminance in apartment Type Illuminance(lux) Task category Ambient 60-100-150 general activities, bathroom 30-40-60 living room (general) Task 300-400-600 reading, dining, cooking 3. DAYLIGHTING PERFORMANCE: 3.1 Daylighting Simulation Daylighting simulation cases are made for the three key seasonal days (March 21st, June 21st and December 21st at noon) and on each day the CIE clear sky condition was selected. 436 daylighting simulations were performed for location of Seoul Korea (latitude 37.5 N; longitude 126.34 E). The slat angles were changed in ±30, ±45, 0 according to shading height to window area (0%, 30%, 60%, 100%). 3.2 Illuminance Figure 3 shows the daylighting illuminance of a prototype blind system incorporating control slat angles and shading height to window area. The preliminary performance data were analysed based on the depth of the space in the window, intermediate and rear wall zone.

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND Shin, H. Y., Lee, Y., Jang, M. S., FOR HEALTHY APARTMENT HOUSING Moon, K. H., Kim, J. T. In equinox season, window zone showed identical daylight performance according to blind height with all slat angles but the degree of upward 45. The case of 100% shading height with +45 tilted slat provided 6.5~15.5 times higher illuminance than other slats. In the illuminance of intermediate and rear wall zone, 30 upward degree showed the most significant performance in 100% shading height for up to 146% light level. In summer, average illuminance was relatively 2 times lower than other seasons due to the higher solar altitude. Shading height of 60% and 100% and +30, +45, 0 tilted slats showed nearly identical daylight performance in middle and rear space with 18~37%, 23~48% higher light level than downward slat angles. According to the change of shading height, upward and horizontal slat angles provided 16%, 13% of low illuminance differences for middle zone while downward tilted angles have showed 50% illuminance differences. a) Equinox (Mar. 21st) b) Summer (June. 21st) In winter season, window zone showed that the high identical light level according to 60% and 100% shading height with upward 30 and 45 tilted slats. An upward 30 slat provided the significantly higher performance in the intermidiate zone regaldless of shading height. In the case of downward slat angles, illuminance of rear wall zone showed 45~90% reduction as shading heights were increased. c) Winter (Dec. 21st) Figure 3. Daylighting illuminacne in seasonal days (south orientation at noon) 3.3 Uniformity Figure 4 showed the illuminance uniformity on seasonal days. In equinox, the internal uniformity of 100% shading height with upward 30 and 0 slat angles provided 4.6times 4

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND Shin, H. Y., Lee, Y., Jang, M. S., FOR HEALTHY APARTMENT HOUSING Moon, K. H., Kim, J. T. increase compare to other slat height. The reason is that the rear zone illuminance was lit by reflective light. In summer (June. 21st), illuminance uniformity provided significant high performance in all kinds of blind controls in comparison with other seasons (i.e., Mar. 21st, Dec. 21st). In the uniformity on Dec. 21st at intermediate zone provided 5.6times decreased due to the high illuminance differences resulted from penetrating direct beam light of low solar position. The shading height of 60% and 100% with downward slat angles has the greatest uniform illuminance of intermediate zone. a) Equinox (Mar. 21st) b) Summer (June. 21st) c) Winter (Dec. 21st) Figure 4. Illuminacne uniformity in seasonal days (south orientation at noon) 4. CONCLUSION For optimal control of venetian blinds, parametric simulations with RADIANCE program have been conducted. The venetian blind with optimal heights and tilted slats could be applied to get more daylight, higher uniformity and more outside view. 1. In equinox, the venetian blind with all shading height and upward slat angles penetrate high daylight performance and fully-closed blind provided high uniformity with slat angle control due to rear wall zone uniformity was rapidly increased. 2. In summer, the venetian blind with all shading height with upward slat angles provided desirable illumination and uniformity as the shading height has not impact on daylight performance. 3. In winter, the venetian blind with shading-height of 60% and 100% and downward slat angles in middle zone provided low illuminance and improves uniformity. Whereas, proper control of shading heights and slat angles for window zone and middle zone should be considered to control direct sunbeam from low angle sunlight.

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND Shin, H. Y., Lee, Y., Jang, M. S., FOR HEALTHY APARTMENT HOUSING Moon, K. H., Kim, J. T. This study is a preliminary simulation-based daylighting performance on the venetian blind systems. Studies on energy demands (i.e., heating, cooling and lighting load) with various parameters (i.e., solar position, shading control, light dimming control) might be considered for further outcomes. Acknowledgement This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (No. 2010-0001860) References 1. Breitenbach, J., Lart, S., Längle, I. and Rosenfeld, J. L. J. (2001). Optical and thermal performance of glazing with integral venetian blinds. Journal of Energy and Buildings, Vol.33, No. 5, pp.433-442 2. International Energy Agency (2000). IEA SHC Task 21Daylighting in Buildings. ECBCS Annex 29 3. Kim, G. and Kim, J. T. (2010). Healthy-daylighting design for the living environment in apartments in Korea. Journal of Building and Environment, Vol.45, No.2, pp.287-294 4. Park, C. S., Augenbroe, G. and Messadi, T. (2003). Daylighting Optimization in Smart Facade Stystem. Proceedings of Eighth International IBPSA Conference, Eindhoven, Netherlands, pp.1001-1007 5. Tzempelikos, A. and Athienitis, A. K. (2007). The impact of shading design and control on building cooling and lighting demands. Journal of Solar Energy, Vol.81, No. 3, pp.369-382 6. Tzempelikos, A. (2008). The impact of venetian blind geometry and tilt angle on view, direct light transmission and interior illuminance, Journal of Solar Energy, Vol.82, No.12, pp.1172-1191 6