Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Similar documents
ATEX Safety Instructions. DYNHRT3MMSS Line Rider

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Quick Start Guide For the

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

manual addendum DELPHI Ex

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

PEPPERL+FUCHS GmbH

IECEx Certificate of Conformity

Earth-Rite II PLUS Static Earthing System

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Technical Data. Dimensions

Certification Supplement Manual

TX6831 Data Sheet. Features. Benefits

Certificate of Compliance

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

INSTRUCTION & SERVICE MANUAL

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Exp, pressurized systems

INSTRUCTION MANUAL (ATEX / IECEx)

Guide for hazardous areas

4) Intrinsic Safety Certification

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Certificate of Compliance

Inductive slot sensor

Operating Instructions

IECEx Certificate of Conformity

Approvals, Certificates and Conditions

ATEX, NOMENCLATURE AND CODING

EU DECLARATION OF CONFORMITY

MICROpeL 75 Combustible Gas Sensor Part Number: PM

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

official distributor of Newson Gale Ltd.

RT FLOW RATE TOTALISER

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Electrical Installations Design, Selection, Erection and Inspection

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX / IECEx)

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

Certificate of Compliance

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Technical Data. General specifications. Rated operating distance s n 5 mm

Explosion-proof Immersion Heater Type D-8660

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Certification Supplement Manual

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Agency Certifications, Recognition and Approvals

ATEX, NOMENCLATURE AND CODING

Certificate of Compliance

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

IECEx Certificate of Conformity

TYPE APPROVAL CERTIFICATE

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Rosemount 752 Fieldbus Remote Indicator

TECHNICAL BULLETIN [ 1 / 10 ]

IECEx Certificate of Conformity

Dräger Polytron 5100 EC Detection of toxic gases and vapors

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

IECEx Certificate of Conformity

Cable Glands DB Series: Drain, Breather Valves and Unions

SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Tank Gauging System Special Safety Instruction

VQ500 Series Combustible Gas Detector Elements

Annubar Flowmeter Series

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

Certificate of Compliance

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

OPTIBAR P 1010/2010 C Supplementary instructions

Intrinsically Safe or Explosionproof? Understanding the technology

Flameproof Manual Call Points Series MCP

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Survey of electrical equipment installed in hazardous areas on tankers

Intrinsically Safe Solutions

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

ELECTRICAL EX EQUIPMENT

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Certificate of Compliance

(German speaking trainers with English written slides)

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Dräger Flame 2100 Flame Detection

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Manual Power relay SR853

GAS DETECTOR ST400EC PART.NO

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

IRceL CH4 Methane (CH 4

Transcription:

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder Load Systems International 2666 Boul du Park-Technologique Québec QC G1P 4S6 Canada www.loadsystems.com

SCOPE This Ex instruction manual must be read and used by qualified personnel during system design and installation of the GS030 Slew Sensor Transmitter and the GS031 Slew Sensor Encoder. These instructions are provided as an addendum to the standard product manuals. MODEL GS030-10 GS031-10 Ex models covered: DESCRIPTION Slew Sensor Transmitter Slew Sensor Warning The GS030 & GS031 are Group IIC Ex ia certified intrinsically safe apparatus which may be installed in Hazardous Area Zone 0, Zone 1 or Zone 2. The GS030 & GS031 must be operated within environmental limitations. The GS030 & GS031 must only be installed by qualified personnel in accordance with the relevant international installation standards The GS030 & GS031 cannot be repaired by the end user thus any units exhibiting a failure must be returned to the manufacturer. SAFETY ANALYSIS In a system safety analysis, always check that the Hazardous Area / Hazardous location devices conform to the relevant standards. INSTALLATION The GS030 & GS031 are fully self-contained and require no special grounding techniques. The GS030 & GS031 have an IP66 rating with fully potted internal electronics and are intended to be mounted outdoors. OPERATION The GS030 is a battery-powered stand-alone device with no interconnecting cables other than the connection to the GS031. Proper operation of the GS030 is indicated by a green LED flashing periodically. Failure of the LED flashing can indicate either a dead battery or no receiver is present within RF Range. STARTUP The GS030 contains a battery and will automatically power on and off when a remote receiver is detected, thus there are no power cables or power switches. When a GS030 detects a remote receiver the green LED will flash on and off periodically. This indicates successful communication with the remote receiver. If there is not a green LED flashing periodically it means either there is not a remote display turned on or the internal battery is dead.

BATTERY REPLACEMENT PROCEDURE Only the battery specified here may be used as a replacement: LSI ORDER CODE MANUFACTURER MANU PART NUMBER DESCRIPTION TB015 TADIRAN TL5930 3.6V 19AHr Lithium D-cell Using another battery may impact the intrinsic safety of the product. Step 1) Step 2) Step 3) Remove the four screws securing the cover to the enclosure body and then remove the cover. Remove the old battery by hand. Install the new battery. MAKE SURE THE POLARITY IS CORRECT. Insert the positive end and then push in the direction of the positive pole. Step 4) Step 5) Re-position the battery cover on the sensor body. Insert the screws, DO NOT OVERTIGHTEN. STORAGE The ambient temperature may exceed the operating temperature limits of -20 C to +40 C without damage for limited periods of time such as may be experienced during air transport. DISPOSAL Please separate and dispose of electronic goods responsibly and follow guidelines and regulations for your region.

SPECIFICATIONS GS030: Compliance ATEX Certificate Number Sira 12ATEX2169X Temperature Classification T4, -20 C < Tamb <+40 C Product Markings ATEX Ex ia IIC T4 Ga -20 C < Ta < +40 C Sira 12ATEX2169X Quality Assurance Notification TRAC 0891 LED Indicators Communicating Green Power Supply Voltage 3.6 VDC nominal Current II 1 G 0891 30 milliamps Physical Dimensions 270mm x120mm x 90mm (l x w x d) Weight Material IP Rating 66 0.95 kg Powder coated Aluminum & Stainless Steel Environmental Operating Temperature -20 C to +40 C Humidity 0 to 100% GS031: Compliance ATEX Certificate Number Sira 12ATEX2169X Temperature Classification T4, -20 C < Tamb <+40 C Product Markings ATEX N/A Quality Assurance Notification TRAC 0891 LED Indicators Communicating Green Power Supply Voltage 3.6 VDC nominal Current 30 milliamps Physical Dimensions (See datasheet for details) Weight 0.45 kg Material IP Rating 66 Stainless Steel & Aluminum Environmental Operating Temperature -20 C to +40 C Humidity 0 to 100%

INSTALLATION CONTROL DRAWING Hazardous Area Hazardous Area Safe Area Ex ia IIC T4-20 C < Tamb < +40 C Ex d IIB T4-30 C < Tamb < 60 C n/a Sira 12ATEX2169X TRAC12ATEX0040X GS030 Slew Transmitter GS820-10 GS030 Slew Sensor Notes: 1) Operating temperature range -20 C < Tamb < +40 C 2) Installation and maintenance must only be done by competent personnel 3) Battery replacement shall only be accomplished if no explosive gas may be present 4) Installation shall be in accordance with 60079.14 and other local regulations as may be required l 5) Dissimilar metal contact should be avoided. Notes: 1) Operating temperature range -30 C < Tamb < +60 C 2) See Installation Instruction GM820-10&11_rev1_20120902 3) Installation and maintenance must only be done by competent personnel 4) GS820-xx must be returned to factory for service 5) Installation shall be in accordance with 60079.14 and other local regulations as may be required l 6) Dissimilar metal contact should be avoided. Notes: 1) Operating temperature range -30 C < Tamb < +60 C 2) Installation and maintenance must only be done by competent personnel 3) Installation shall be in accordance local regulations as may be required 4) Dissimilar metal contact should be avoided.

Document Revision History Revision History Rev Date Description Approved 1 01-22-2015 Draft Release. M. Chouinard Any changes to this document must be approved by the Hazardous Area Systems Manager