GAI-Tronics Systems NEW! Elemec3 Digitally Controlled PA and General Alarm system PA/GA

Similar documents
Elemec3. Networked Public Address and General Alarm System (PA/GA)

VACIE REFERENCE GUIDE REVISION 1.2.6

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Vocia VACIE. Reference Guide

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

GAI-Tronics Corporation. Serverless Page Party (SP2) Publication : SP2 Intelligent Intra-Plant Communication and Emergency Notification System

EN ASTRO-PA/GA System. ASTRO-PAGA Digital IP Public Address & General Alarm SYSTEM for INDUSTRIAL SAFETY APPLICATIONS

Call stations and extensions

SP40S-D. Kingfisher Company, inc. Features: Description:

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Public Address and General Alarms (PAGA) Spector Lumenex Communication Systems for Life Safety Applications

AE300. Integrated Voice Alarm System

ECC-50/100C. Emergency Command Center

OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES

Autonomous control unit

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

The New Standard In Safety

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

Bosch Plena Public Address and Voice Alarm System The fast route to safety

16 Zone Voice Evacuation VA & PA Sound System

SAFEPATH DoD facility communications system & expansion options

SAFEPATH Mass Notification System (SPMNS)

Intelligent Security & Fire Ltd

For Complete Fire and Gas Solutions

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

PA/VA solutions for transport industry

SECURE LIFE SAFETY PAGA

Get all messages across, no matter what.

TELECOMMUNICATION. Telecommunication. Wireless Phone

Public Address Project Combisound System

X-618 Digital Public Address and Voice Alarm System. Cherian George Product Manager PAVA systems

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

ECC-50/100(E) Emergency Command Center

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5

AutroVoice voice alarm system AUTROVOICE VOICE ALARM. Loud and clear information

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

DOCUMENTATION HANDBOOK MPA 1600 PUBLIC ADDRESS AND GENERAL ALARM SYSTEM.

tyco PAVA IP Audio Voice Alarm Router tyco PAVA Systems Features : K ƉƟŽŶĂůD ŽĚƵůĞƐ

EQUIPMENT SPECIFICATION. GAI-TRONICS ADDRESSABLE AMPLIFIED SPEAKER and AUDIO MESSENGER INTERFACE PRODUCTS

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

LORAIN CIP 4890/48120 DC Power System

Alarm Tone Generator Model AG17

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

Solutions for Mass Notification Systems

Milano, 25 novembre 2015

POPE FRANCIS HIGH SCHOOL SPRINGFIELD, MA BID SPECIFICATION PUBLIC ADDRESS AND INTERCOM SYSTEM

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Emergency Communications Tower Applications (Solar/Wireless/Surveillance)

SAFEPATH SAFEPATH. Emergency communications system

Entero Voice Alarm system.

ACP10 & ACP50 Security Systems

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

TrueAlarm Fire Alarm Controls

E3 Series Broadband System

Emergency/Help Point Analog Telephones & Correctional Analog Telephones

The Standard In Safety

VOICE ALARMING SYSTEM»ONE-BOX-DESIGN« EN / EN 54-4 / VDE / EN / VDE 0828 THE SIMPLE»ALL-IN-ONE«SOLUTION.

Engineering Guideline. pac- Carriers Type Universal

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

M2500 Engine Controller Installation Manual

380 SERIES REMOTE SIREN ETSA380R

Fire and Gas Monitoring Panel ST7-HV

AUDIO- AND ALARMMANAGEMENT

Rugged Telephones GAI-TRONICS. A Hubbell Company

PUBLIC ADDRESS, BACKGROUND MUSIC AND VOICE ALARM SYSTEM

STATUS ALARM HISTORY ALARM RESET

i.net Engineered system solutions for

sirens speakers and programmable controls

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

N-8000 SERIES IP INTERCOM SYSTEM

WELCOME. The human touch in technology. marine

by Honeywell VOICE ALARM SOLUTIONS BROCHURE

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

Building Technologies

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Solution F2. Fire Alarm Control Panels one step ahead.

E3 Series Broadband System

LOCAL & GLOBAL. Voice Alarm System. Smart public address system.

FireFinder XLSV Digital Emergency Voice Alarm / Communication System

AUDIBLE SIGNALIZATION

Entero Voice Alarm system. User guide

IEC Electroacoustic EMERGENCY WARNING SYSTEM. for a maximum of system security 79

NU2 Smart Power Supply (SPS) Manual

July 14, 1999 DF C-100.

PUBLIC ADDRESS SYSTEM

5000 INSTALLATION GUIDE

sirens speakers and programmable controls

Specification/ Data Sheet

Informer-IP Desk Mount

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Transcription:

The Elemec3 is a digitally controlled Public Address and General Alarm (PA/GA) system. Designed principally for life critical installations in the Oil and Gas market, it is also suitable for many industrial communications requirements. The Elemec3 high integrity PA/GA system is commonly used on Oil & Gas Platforms, FPSOs, Power Stations & Oil Refineries, Chemical Plants & Industrial Complexes worldwide where the safety of all personnel is of immense importance. The equipment is specifically and fundamentally designed for failsafe operation, with extensive system and fault status monitoring for maximum availability at all times. In addition to general paging and emergency broadcasts, alarms can be automatically initiated, e.g. from fire and gas alarm and emergency shut down systems. Alarm tones or pre-recorded digital voice evacuation messages can be broadcast. For ease of installation and maintenance all cabinet internal connections are on a plug/socket basis. System expansion is easily achieved by simply adding more modules and reconfiguring the system software accordingly. Class D intelligent power amplifiers Dual 300W (D600i), Single 550W (D550i) or Single 300W (D300i) Up to 35.2 kw (64 amplifiers) of audio power Up to 64 programmable audio zones Fully duplicated, redundant or single configuration Compliant to UKOOA, PFEER, IMO, ABS, SOLAS, DNV, CCS, NORSOK guidelines Multiple hot standby power amplifiers Modular design for easy maintenance Up to 16 fully monitored & feature rich programmable access panels Message storage and replay up to 25MB System status and fault monitoring via Portal remote monitoring software Intrinsically Safe ATEX/IEC Ex access panels to Group IIB Two audio paths for simultaneous broadcasting requirements, in accordance with IEC 60849 Background Music (BGM) option PABX telephone access Page/Party access Engineers test panel Optional fibre optic links Auto alarm inhibit via key switch Beacon cable monitoring Ultrasonic loudspeaker network monitoring 256 inputs / outputs CE compliant

System Controller Designed for 19" equipment cabinet mounting, the 1U Elemec3 system controller is microprocessor controlled and software configurable. This control unit continuously monitors the system modules (microphone access panels, alarm tone generators, I/O modules and power amplifiers etc.) to ensure a high level of integrity and reliability is achieved. Audio enhancement circuitry has been included within the controller design to ensure that the quality of speech and intelligibility meets industry standards. The system controller can be supplied in duplicated or main and standby formats for additional redundancy. It includes a vast range of features such as the capability to adjust the volume of individual amplifiers; auto adjust of hot standby volume to meet the amplifier volume that has been substituted; and PABX interface features, including DTMF misuse, zoning & activation of alarms. Event schedules (i.e. weekly alarm testing or scheduled messages) can be configured to activate automatically. The Elemec3 system controller ensures that the system can be easily configured to meet the customer s requirements whilst maintaining a set of standard building modules. Portal Remote Monitoring Software Home Page Event Status Fault Status The unique Portal software enables remote monitoring of the system. The Portal is connected to Elemec3 via LAN, WAN, direct, or connected to the Internet, giving world-wide access to system monitoring; a major advantage for maintenance personnel. Real time status of the system s alarm and beacon outputs, together with the control inputs can be monitored. Monitored Relay Module (MRM) & Monitored Input Module (MIM) The Monitored Relay Module (MRM) controls relays typically used for PA/GA alarm notification, e.g. strobe lights to supplement alarm broadcasts. The MRM is capable of switching and supervising eight (8) relay circuits. This enables the user to monitor inputs from other devices such as the fire & gas system, extending the monitoring capacity of the connection. Additionally, it allows the user to have a remote display of all current messages processed by the system controller within the Elemec3 equipment cabinet(s). The Monitored Input Module (MIM) interrogates switch status changes for an alarm initiation request or various line fault conditions. The MIM is capable of supervising eight (8) alarm initiating lines. Each line can be configured independently to monitor single or multiple switch activation or deactivated if not used. For both MRM and MIM, all lines are supervised for open, short circuits and earth leakage faults.

Class D Intelligent Power Amplifier The Class D intelligent power amplifier is designed for use in GAI-Tronics high integrity PA/GA systems. The field proven amplifier is designed for performance in a range of applications, from continuous 300W RMS rated outputs for Alarm Systems to high quality music reproduction. Each D600i amplifier comprises of 2 x 300W channels, each capable of independent operation. Alternatively, single 300W units can be provided or 550W units if greater audio power is needed. Fault protection and ultrasonic load sensing are contained within the Amplifier. Load sensing is easily configured by use of pushbuttons on the front of each amplifier. This facility allows loudspeaker monitoring and automatically detects changes in the load of the connected loudspeakers. Thermostatically controlled fans, integral to each unit, provide forced air cooling to the output power devices only during high temperature operation. Hot standby amplifier control can be provided whereby a powered spare amplifier(s) is automatically connected to the loudspeaker network of a failed amplifier(s). Access s A range of access panels are available for use with the Elemec3 PA/GA system. All panels are monitored for integrity and communicate via a 3 pair cable regardless of the standard features selected. 19 console, desktop and bulkhead access panels are available for indoor and outdoor use and suitable for both safe and hazardous areas. Each of these variants use the same standardised panel insert. For hazardous areas, muster panels can be supplied for Zone 1, ATEX certified to EEx ib IIB T4. The access panel insert assembly comprises a mild steel plate pierced to accommodate 30 pushbuttons, with a textured polycarbonate overlay and 'secret until lit' status indicators. Pushbuttons can be individually programmed by software to perform any of the microphone panel functions (zone selection, alarm tones, routine & emergency speech etc.). Emergency speech and alarm pushbuttons can be fitted behind a Perspex cover to prevent accidental operation. 'All call' and Sleeping Quarter zone pushbuttons can similarly be fitted behind the cover if required. Gooseneck or fist microphone options are available with VU indication. LEDs adjacent to the pushbuttons illuminate only when the switch press has been accepted by the Central Equipment to provide added confidence to the operator. Pushbutton legends are easily interchangeable. Up to 16 fully fitted microphone panels can be connected to the Elemec3 PA/GA system. Audio broadcasts can be prioritised in order to prevent routine announcements overriding Alarm tones and Emergency messages. During Emergency Speech broadcasts the audible Alarms can be programmed to attenuate (typically 12dB) or mute for the duration of the announcement.

TECHNICAL SPECIFICATIONS System Controller Keyswitch - Used to inhibit Auto Alarm inputs e.g. to prevent false alarms during fire and gas system commissioning. USB Ports - to upload alarm tones Status Indicators for PA in use, system status, and power SD Card - to store alarm tones and messages Dimensions: W431.8 x H43.7 x D226.3 (mm) DIN standard 1U Material: Aluminum Power 24V DC +/-10% <800mA (unit itself) 100mA fused outputs provided for Access s, Beacon Relays etc. Microphone Audio Input 2.2V p.p. 600Ω Microphone Data Page/Party interface Input Level 1.5V rms CAN BUS to Input/Output Cards Amplifier Audio Output 2.2V p.p. Amplifier Data Link RS485 semi-duplex A/B System interlink 9 pair connection Audio 2.2V p.p. Auxiliary Inputs e.g. background music 2.2V p.p. 600Ω Auxiliary outputs e.g. voice recording 2.2V p.p. 600Ω Remote diagnostics and configuration Class D Intelligent Power Amplifier LCD Indicator on the front of the amplifier displays the following information: High Temperature Operation Output Overload Condition Amplifier Shutdown Protection Active Power Healthy Amplifier Enabled / Disabled Fuse Failure Zone Allocation Bargraph (output level) Output power: 2 x 300W, 1 x 550W, 1 x 300W Line output voltage: 70V or 100V rms (or client spec) Input sensitivity: 0dBm (0.775V rms) for rated output Frequency response: 50Hz - 18kHz (-3dB points) Total harmonic distortion: <2% at 1kHz, full load Access Up to 30 pushbuttons System Status indicators 300mm gooseneck or fist microphone 3 pair connection cable Power 24V DC nominal (15-30V DC) <65mA Audio Pair, uni-directional, 2.2V pp Data pair, RS485 semi-duplex Audio Conditioning 2:1 compression VU Meter LEDs in 6dB steps S/N Ratio >60dB Environmental -20 C to +50 C PART NUMBERS: Contact GAI-Tronics 19" Console Desktop Indoor Bulkhead Outdoor Bulkhead GRP PART NUMBER: 013-02-0095-002 Operating Voltage Options: 48V DC, Mains 120V or 230V AC Operating Temperature: -20 C to +50 C Efficiency: 80% (typ) Signal to Noise ratio: 60dB (A) Dimensions: 483W x 88H x 390D (mm) DIN standard 2U Mounting: 19" Standard Rack (Shelf or Slider) Material: Welded Steel Tray with Vented Lid Finish: Black Textured Stoved Enamel Output Audio Connectors: WAGO 5 way connector AC Power: IEEE Standard, 3 pin DC Power: Molex 2 way 100mm Mini Fit connector Audio / Data Comms (RS485): IDC Weight: 24Kg max PART NUMBERS: Contact GAI-Tronics Dimensions Mounting Material Connections 483W x 177H x 135D (mm) 269W x 90H x 230D (mm) 450W x 324H x 173D (mm) 400W x 300H x 210D (mm) 280W x 280H x 170D (mm) 19" Console Mild Steel Desktop Mild Steel Mild Steel Stainless Steel Glass Reinforced Polycarbonate 15 way 'D' connector Enclos ure Resistance IP66 (door closed) IP66

GAI-Tronics - United Kingdom - Tel: +44 (0)1283 500500 - Fax: +44 (0)1283 500400 - www.gai-tronics.co.uk GAI-Tronics (Corporate) - USA - Tel: +1(610) 777 1374 - Toll Free: 800 492 1212 - Fax: +1(610) 796 5954 - www.gai-tronics.com GAI-Tronics S.r.l - Italy - Tel: +39 02 48601 460 - Fax: +39 02 4585 625 - www.gai-tronics.co.uk GAI-Tronics - Malaysia - Tel: +60 3 8945 4035 - Fax: +60 3 8945 4675 - www.gai-tronics.co.uk GAI-Tronics Austdac - Australia - Tel: 011 61 28 851 5000 - Fax: 011 61 29 899 2490 - www.austdac.com.au An ISO 9001, ISO 14001, OHSAS 18001 Registered Company The policy of GAI-Tronics is one of continuous improvement; therefore the company reserves the right to change specifications without notice. B209-1-0513B/37825-001