PACKAGE AIR CONDITIONING UNITS

Similar documents
PACKAGE AIR CONDITIONING UNITS

Rheem Commercial Value Series Package Air Conditioner

SELF-CONTAINED COOLING PACKAGE UNITS

Ruud Commercial Achiever Series Package Air Conditioner. Package Air Conditioner

Ruud Commercial Achiever Series Package Air Conditioner. Package Air Conditioner

Ruud Commercial Value Series Package Gas Electric Unit

Ruud Commercial Value Series Package Gas Electric Unit

Ruud Commercial Value Series Package Gas Electric Unit

Ruud Commercial Value Series Package Gas Electric Unit

Rheem Commercial Prestige Series Package Air Conditioner

Ruud Commercial Achiever Series Package Gas Electric Unit

MAINLINE COMMERCIAL PACKAGE AIR CONDITIONER

MAINLINE COMMERCIAL PACKAGE AIR CONDITIONER

SELF-CONTAINED AIR CONDITIONERS

Ruud Commercial Achiever Series Package Gas Electric Unit featuring HumidiDry Technology

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Commercial Achiever Series Package Air Conditioner. Package Air Conditioner

PACKAGE AIR CONDITIONERS

SELF-CONTAINED HEAT PUMP PACKAGE UNITS

Unit Features & Benefits RQPM/RQRM Series

Ruud Commercial Achiever Series Package Gas Electric Unit featuring HumidiDry Technology

INSTALLATION INSTRUCTIONS

Rheem Commercial Classic Series Package Air Conditioner

INSTALLATION INSTRUCTIONS

H 2 AC Rooftop Unit featuring esync Integration Technology

Rheem Commercial Classic Series Package Gas Electric Unit

H 2 AC Rooftop Unit featuring esync Integration Technology

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

H 2 AC Rooftop Unit featuring esync Integration Technology

Ruud Commercial Achiever Series Package Air Conditioner featuring HumidiDry Technology

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric Tons, 50 Hz RT-PRC073B-EN. May 2018

RHEEM PACKAGE GAS/ELECTRIC

PACKAGE AIR CONDITIONER

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Commercial High-Efficiency Condensing Units

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Packaged Heat Pumps. Voyager 12½ to 20 Tons 60 Hz PKGP-PRC001-EN. September 2004

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

INSTALLATION INSTRUCTIONS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Product Data. Fig. 1 - Unit 50VR -A

Split System Heat Pumps

50TM COMBINATION HEATING/COOLING UNITS

DCG Commercial. Submittal Data Form

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

48PGD/E/F/L/M/N PG20-28

Packaged Cooling with Electric Heat Rooftop Units

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Roof Top Packaged Unit (RTU-1) Specification

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Packaged Cooling with Electric Heat Rooftop Units

PAJ3. Product Specifications

Product Catalog. Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 3 to 5 Tons, 60Hz RT-PRC078C-EN.

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

High Heat COP. High/Low Stage

50TM TFF COMBINATION HEATING/COOLING UNITS

Packaged Heat Pumps. Precedent - R Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC003-EN. November 2008

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

48TM GAS HEATING/ELECTRIC COOLING UNITS

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

PRODUCT CATALOG. Logo Not Found. ruud.com. Rely on Ruud.

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

C13-Series Engineering Guide

PAR5. Product Specifications

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Model 655A Sizes

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Product Catalog. Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 15 to 25 Tons, 60 Hz RT-PRC060H-EN.

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Packaged Heat Pumps. Precedent - R-410A Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC013-EN. August 2009

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

VertiCool Aurora Engineering Guide

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

Installation and Maintenance Manual IM

Commercial High-Efficiency Condensing Units

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Packaged Heat Pumps. Precedent Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC003-EN. February 2007

Packaged Gas/Electric Rooftop Units

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

Transcription:

PACKAGE AIR CONDITIONING UNITS FORM NO. S-942 REV. Supersedes Form No. S-942 Featuring Industry Standard R-40A Refrigerant RLKL-B HIGH EFFICIENCY SERIES NOMINAL SIZES 7.5, 0 & 2.5 TON [26.4, 5.2 & 44.0 kw] ASHRAE 90.-200 COMPLIANT MODELS Proper sizing and installation of equipment is critical to achieve optimal performance. Ask your Contractor for details or visit www.energystar.gov.

TABLE OF CONTENTS Unit Features & Benefits...-7 Selection Procedure...8 Model Identification Options...9-0 General Data RLKL-B- Series...-6 General Data Notes...7 Performance Data RLKL-B- Series...8-9 Airflow Performance RLKL-B- Series...20-22 Electrical Data RLKL-B- Series...2-25 Units with Heater Kits...26- Dimensional Data...2-5 Accessories...6-55 Mechanical Specifications...56-57 Typical Wiring...58-6 Limited Warranty...64 2

UNIT FEATURES & BENEFITSRLKL-B SERIES These quality features are included in the Rheem Package Air Conditioner Unit STANDARD FEATURES INCLUDE: R-40A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and highpressure protection. Single stage compressor. Convertible airflow. Orifice metering system on 7.5 and 0 ton. TXV metering on 2.5 ton. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, single pass designed evaporator and condenser coils facilitate easy cleaning for maintained high efficiencies. MicroChannel outdoor coil. Cooling operation up to 25 degree F ambient. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Mechanical fasteners, door with heavy-duty gasketing. Slide Out Indoor fan assembly for added service convenience. Powder Paint Finish meets ASTMB7 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Forkable base rails for easy handling and lifting. Single point electrical connections. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 2 inch filter standard with slide out design. 24 volt control system with resettable circuit breakers. Colored and labeled wiring. Molded compressor plug. Supplemental electric heat provides 00% efficient heating.

UNIT FEATURES & BENEFITSRLKL-B SERIES 2 4 7 5 Rheem Package equipment is designed from the ground up with the latest features and benefits required to compete in today s market. The clean design stands alone in the industry and is a testament to the quality, reliability, ease of installation and serviceability that goes into each unit. Outwardly, the large Rheem Commercial Series label ( ) identifies the brand to the customer. The sheet-metal cabinet ( 2 ) uses nothing less than 8- gauge material for structural components with an underlying coat of G90. To ensure the leak-proof integrity of these units, the design utilizes a one-piece top with a /8" drip lip ( ), gasketprotected panels and screws. The Rheem hail guard (optional) ( 4 ) is its trademark, and sets the standard for coil protection in the industry. Every Rheem package unit uses the toughest finish in the industry, using electro deposition baked-on enamel tested to withstand a rigorous 000-hour salt spray test, per ASTM B7. Anything built to last must start with the right foundation. In this case, the foundation is 4-gauge, commercial-grade, full-perimeter base rails ( 5 ), which integrate fork slots and rigging holes to save set-up time on the job site. The base pan is stamped, which forms a -/8" flange around the supply and return cover and has eliminated the worry of water entering the conditioned space ( 6 ). The insulation has been placed on the underside of the basepan, removing areas that would allow for potential moisture accumulation, which can facilitate growth of harmful bacteria. All insulation is secured with both adhesive and mechanical fasteners, and all edges are hidden. The drainpan ( 7 ) is made of material that resists the growth of harmful bacteria and is sloped for the latest IAQ benefits. Furthermore, the drain pan slides out for easy cleaning. 6 6 During development, each unit was tested to U.L. 995, AHRI 40-70 and other Rheem-required reliability tests. Rheem adheres to stringent IS0 9002 quality procedures, and each unit bears the U.L. and AHRI certification labels located on the unit nameplate. Contractors can rest assured that when a Rheem package unit arrives at the job, it is ready to go with a factory charge and quality checks. Each unit also proudly displays the Made in the USA designation. Access to all major compartments is from the front of the unit, including the filter and electrical compartment, blower compartment, heating section, and outdoor section. Each compartment has mechanical fasteners. Each panel is permanently embossed with the compartment name (control/filter access, blower access and electric heat access). Electrical and filter compartment access is through a large, mechanically fastened panel. On the outside of the panel is the unit nameplate, which contains the model and serial number, electrical data and other important unit information. The unit charging chart is located on the inside of the electrical and filter compartment door. Electrical wiring diagrams are found on 8 the control box cover, which allows contractors to move them to more readable locations. To the right of the control box the model and serial number can be found. Having this information on the inside will assure model identification for the life of the product. 9 The production line quality test assurance label is also placed in this location ( 8 ). The two-inch throwaway filters ( 9 ) are easily removed on a tracked system for easy replacement. 4

UNIT FEATURES & BENEFITSRLKL-B SERIES 9 Inside the control box ( 0 ), each electrical component is clearly identified with a label that matches the component to the wire diagram for ease of trouble shooting. All wiring is numbered on each end of the termination and colorcoded to match the wiring diagram. The control transformer has a low voltage circuit breaker that trips if a low voltage electrical short occurs. There is a blower contactor and compressor for each compressor. For added convenience in the field, a factory-installed convenience outlet ( ) is available. Low and High voltage can enter either from the side or through the base. Low-voltage connections are made integrated cooling control. The high-voltage connection is terminated at the number compressor contactor. The suggested mounting for the field-installed disconnect is on the exterior side of the electrical control box. 0 maintenance of the blower assembly, the entire assembly easily slides out by removing the /8" screws from the blower retention bracket. The adjustable motor pulley ( ) can easily be adjusted by loosening the bolts on either side of the motor mount. Removing the bolts allows for easy removal of the blower pulley by pushing the blower assembly up to loosen the belt. Once the pulley is removed, the motor sheave can be adjusted to the desired number of turns, ranging from 0 to 6 turns open. Where the demands for the job require high static, Rheem has high-static drives available that deliver nominal airflow up to 2" of static. By referring to the airflow performance tables listed in the installation instructions, proper static pressure and CFM requirements can be dialed in. The scroll housing ( 4 ) and blower scroll provide quiet and efficient airflow. The blower sheave is secured by an H bushing which firmly secures the pulley to the blower shaft for years of trouble-free operation. The H bushing allows for easy removal of the blower pulley from the shaft, as opposed to the use of a set screw, which can score the shaft, creating burrs that make blower-pulley removal difficult. 4 To the right of the electrical and filter compartment are the externally mounted gauge ports, which are permanently identified by embossed wording that clearly identifies the compressor circuit, high pressure connection and low pressure connection ( 2 ). With the gauge 2 ports mounted externally, an accurate diagnostic of system operation can be performed quickly and easily. The blower compartment is to the right of the gauge ports and can be accessed by removing mechanical turn fasteners. To allow easy 5

UNIT FEATURES & BENEFITSRLKL-B SERIES Also inside the blower compartment is the low-ambient control ( 5 ), low-pressure switch ( 6 ), high-pressure switch ( 7 ) and freeze stat refrigerant safety device ( 8 ) (optional). The lowambient control allows for operation of the compressor down to 0 6 degrees ambient temperature by 7 cycling the outdoor fans on high pressure. The high-pressure switch will shut off the compressors if pressures exceeds, 60 5 PSIG are detected, this may occur if the outdoor fan motor fails. The low-pressure switch shuts off the compressors if low pressure is detected due to loss of charge. The freeze stat protects the compressor if the evaporator coil gets too cold (below freezing) due to low airflow. Each factory-installed option is brazed into the appropriate high or low side and wired appropriately. Use of polarized plugs and sharder fittings allow for easy field installation. Inside the blower compartment the interlaced evaporator can also be viewed. The evaporator uses enhanced fin technology for maximum heat transfer. The fixed orifice metering device (TXV s on 2.5 ton) assures even distribution of refrigerant throughout the evaporator. MicroChannel technology is used on outdoor coil. Wiring throughout the unit is neatly bundled and routed. Where wire harnesses go through the condenser bulkhead or blower deck, a molded wire harness assembly ( 9 ) provides an air-tight and water-tight seal, and provides strain relief. Care is also taken to tuck raw edges of insulation behind sheet metal to improve indoor air quality. 9 24 20 2 25 22 The heating compartment contains the latest electric furnace technology on the market. The 00% efficient electric furnace can be factory-installed or easily field-installed. Built with easeof-installation in mind, the electric furnace is completely wired for slide-in, plug-and-play installation in the field. With choices of up to six kilowatt offerings, the contractor is assured to get the correct amount of heating output to meet the designed heating load. Power hook-up in the field is easy with single-point wiring to a terminal block ( 20 ) and a polarized plug for the low-voltage connection ( 2 ). The electric furnace comes with fuses for the unit ( 22 ) and for the electric furnace ( 2 ), and is UL certified ( 24 ). The electric heating elements are of a wound-wire construction ( 25 ) and isolated with ceramic bushings. The limit switch ( 26 ) protects the design from over-temperature conditions. Each electric furnace has the capability to be converted from single-stage operation to two-stage operation by removing a jumper on the low-voltage terminal strip. 26 2 6

UNIT FEATURES & BENEFITSRLKL-B SERIES The compressor compartment houses the heartbeat of the unit. The scroll compressor ( 28 ) is known for its long life, and for reliable, quiet, and efficient operation. The suction and discharge lines are designed with shock loops ( 29 ) to absorb the strain and stress that the starting torque, steady state operation, and shut down cycle impose on the refrigerant tubing. Each unit comes standard with filter 29 dryer ( 0 ). The condenser fan motor ( ) can easily be accessed and maintained through the compressor compartment. The polarized plug connection allows the motor to be changed quickly and eliminates the need to snake wires through the unit. 0 The outdoor coil uses the latest MicroChannel technology ( 2 ) for the most effective method of heat transfer. The outdoor coil is protected by optional louvered panels, which allow unobstructed airflow while protecting the unit from both Mother Nature and vandalism. 28 2 Each unit is designed for both downflow or horizontal applications ( ) for job configuration flexibility. The return air compartment can also contain an economizer ( 4 ). Four models exits, one for downflow applications, and one for horizontal applications each with or without smoke detector. Each unit is prewired for the economizer to allow quick plug-in installation. The economizer is also available as a factoryinstalled option. Power Exhaust is easily field-installed. The economizer, which provides free cooling when outdoor conditions are suitable and also provides fresh air to meet local requirements, comes standard with single enthalpy controls. The controls can be upgraded to dual enthalpy easily in the field. The direct drive actuator combined with gear drive dampers has eliminated the need for linkage adjustment in the field. The economizer control has a minimum position setpoint, an outdoor-air setpoint, a mix-air setpoint, and a CO 2 setpoint. Barometric relief is standard on all economizers. The power exhaust is housed in the barometric relief opening and is easily slipped in with a plug-in assembly. The wire harness to the economizer also has accommodations for a smoke detector. 4 4 The Rheem roofcurb ( 5 ) is made for toolless assembly at the jobsite by engaging a pin into the hinged corner brackets into the adjacent curb sides, which makes the assembly process quick and easy. 5 7

SELECTION PROCEDURE EXAMPLERLKL-B SERIES To select an RLKL- Cooling and Heating unit to meet a job requirement, follow this procedure, with example, using data supplied in this specification sheet.. DETERMINE COOLING AND HEATING REQUIREMENTS AND SPECIFIC OPERATING CONDITIONS FROM PLANS AND SPECS. Example: Total cooling capacity 06,000 BTUH [.26 kw] Sensible cooling capacity 82,000 BTUH [24.0 kw] Heating capacity 50,000 BTUH [4.96 kw] *Condenser Entering Air 95 F [5 C] DB *Evaporator Mixed Air Entering65 F [8 C] WB; 78 F [26 C] DB *Indoor Air Flow (vertical) 600 CFM [699 L/s] *External Static Pressure.40 in. WG 2. SELECT UNIT TO MEET COOLING REQUIREMENTS. Since total cooling is within the range of a nominal 0 ton [5.2 kw] unit, enter cooling performance table at 95 F [5 C] DB condenser inlet air. Interpolate between 6 F [2 C] and 67 F [9 C] to determine total and sensible capacity and power input for 65 F [8 C] WB evap inlet air at 4000 CFM [888 L/s] indoor air flow (table basis): Total Capacity = 8,900 BTUH [4.80 kw] Sensible Capacity = 99,950 BTUH [29.29 kw] Power Input (Compressor and Cond. Fans) = 8,950 watts Use formula [.0 x CFM x ( DR) x (dbe 80)] in note to determine sensible capacity at 80 F [26.7 C] DB evaporator entering air: Sensible Capacity = 92,268 BTUH [27.24 kw]. CORRECT CAPACITIES OF STEP 2 FOR ACTUAL AIR FLOW. Select factors from airflow correction table at 600 CFM [699 L/s] and apply to data obtained in step 2 to obtain gross capacity: Total Capacity, 8,900 x.98 = 6,522 BTUH [4.5 kw] Sensible Capacity, 92,268 x.95 = 87,655 BTUH [25.67 kw] Power Input,650 x.99 = 8,86 Watts These are Gross Capacities, not corrected for blower motor heat or power. 5. CALCULATE INDOOR BLOWER BTUH HEAT EFFECT FROM MOTOR WATTS, STEP 4. BTUH =,650 x.42 = 5,60 6. CALCULATE NET COOLING CAPACITIES, EQUAL TO GROSS CAPACITY, STEP, MINUS INDOOR BLOWER MOTOR HEAT. Net Total Capacity = 6,522 5,60 = 0,892 BTUH [2.5 kw] Net Sensible Capacity = 87,655 5,60 = 82,025 BTUH [24.04 kw] 7. CALCULATE UNIT INPUT AND JOB EER. Total Power Input = 88,60 (step ) +,650 (step 4) = 0,5 Watts EER = Net Total BTUH [kw] (step 6) = 0,892 = 0.55 Power Input, Watts (above) 0,5 8. SELECT UNIT HEATING CAPACITY. Units with heater kits section find unit heater kw and convert watts to BTU: add blower BTUH heat effect (step 5). CC5C Heater Kit kw x 42 = 6,776 BTUH [48.00 kw] + 5,60 BTUH [.65 kw] Heating Capacity = 69,406 BTUH [49.65 kw] *NOTE: These operating conditions are typical of a commercial application in a 95 F/79 F [5 C/26 C] design area with indoor design of 76 F [24 C] DB and 50% RH and 0% ventilation air, with the unit roof mounted and centered on the zone it conditions by ducts. 4. DETERMINE BLOWER SPEED AND WATTS TO MEET SYSTEM DESIGN. Enter Indoor Blower performance table at 600 CFM [699 L/s]. Total ESP (external static pressure) per the spec of.40 in. includes the system duct and grilles. Add from the table Component Air Resistance,.076 for wet coil,. for vertical air flow, for a total selection static pressure of.606 (.6) inches of water, and determine: RPM = 796 WATTS =,650 DRIVE = L (standard 2 H.P. motor) 8

MODEL IDENTIFICATIONRLKL-B SERIES R L K L B 20 C L 000 X X X Economizer Option (See Next Page) Factory Installed Options (See Next Page) Electric Heat 000 = No Resistance Heat 00 = 0 kw Resistance Heat 05 = 5 kw Resistance Heat 020 = 20 kw Resistance Heat 00 = 0 kw Resistance Heat 040 = 40 kw Resistance Heat 050 = 50 kw Resistance Heat Drive Package L = Belt Drive M = Belt DriveHigh Static (20 & 5) N = Belt DriveHigh Static (090) Electrical Designation C = 208-20 V, PH, 60 Hz D = 460 V, PH, 60 Hz Y = 575 V, PH, 60 Hz Cooling Capacity (BTUH) [kw] 090 = 90,000 [26.8] 20 = 20,000 [5.7] 5 = 50,000 [44.0] Future Technical Variations Design Series L = R40A Efficiency Designation K = ASHRAE 90.-200 Compliant Product Classification L = Packaged Air Conditioner = Commercial Tradebrand R = Rheem Packaged Gas/Electric 9

OPTIONSRLKL-B SERIES 7.5, 0, & 2.5 TON [26.4, 5.2 & 44.0 kw] Option Code Hail Guard Non-Powered Convenience Outlet Low Ambient/ Freeze Stat AD x AG x AP x BY x x BJ x x CX x x x JC x x x indicates factory installed option. ECONOMIZER SELECTION FOR LKL 7.5, 0, & 2.5 TON [26.4, 5.2 & 44.0 kw] No Economizer A x B C x indicates factory installed option. Single Enthalpy Economizer with Barometric Relief x Single Enthalpy Economizer with Barometric Relief and Smoke Detector x Instructions for Factory Installed Option(s) Selection Note: Three characters following the model number will be utilized to designate a factory-installed option or combination of options. If no factory option(s) is required, nothing follows the model number. Step. After a basic rooftop model is selected, choose a two-character option code from the FACTORY INSTALLED OPTION SELECTION TABLE. Proceed to Step 2. Step 2. The last option code character is utilized for factory-installed economizers. Choose a character from the FACTORY INSTALLED ECONOMIZER SELECTION TABLE. Examples: RLKL-B20CL000...this unit has no factory installed options. RLKL-B20CL000ADA...this unit is equipped with hail guards. RLKL-B20CL000BYA...this unit is equipped with hail guards, low ambient and unit freeze stat. RLKL-B20CL000BYB...this unit is equipped as above and includes an Economizer with single enthalpy sensor and with barometric relief. RLKL-B20CL000AAC...this unit is equipped with an Economizer with single enthalpy sensor and barometric relief with smoke detector. 0

GENERAL DATARLKL-B SERIES NOM. SIZES 7.5, 0, & 2.5 TON [26.4, 5.2 & 44.0 kw] ASHRAE 90.-200 COMPLIANT MODELS Model RLKL- Series B090CL B090CM B090CN B090DL Cooling Performance Gross Cooling Capacity Btu [kw] 87,000 [25.49] 87,000 [25.49] 87,000 [25.49] 87,000 [25.49] EER/SEER 2.2/NA.2/NA.2/NA.2/NA Nominal CFM/AHRI Rated CFM [L/s] 2800/2925 [2/80] 2800/2925 [2/80] 2800/2925 [2/80] 2800/2925 [2/80] AHRI Net Cooling Capacity Btu [kw] 84,000 [24.6] 84,000 [24.6] 84,000 [24.6] 84,000 [24.6] Net Sensible Capacity Btu [kw] 64,800 [8.99] 64,800 [8.99] 64,800 [8.99] 64,800 [8.99] Net Latent Capacity Btu [kw] 9,200 [5.6] 9,200 [5.6] 9,200 [5.6] 9,200 [5.6] IEER 2. 2. 2. 2. Net System Power kw 7.5 7.5 7.5 7.5 Compressor No./Type /Scroll /Scroll /Scroll /Scroll Outdoor Sound Rating (db) 4 88 88 88 88 Outdoor Coil - Fin Type Louvered Louvered Louvered Louvered Tube Type MicroChannel MicroChannel MicroChannel MicroChannel MicroChannel Depth in. [mm] [25.4] [25.4] [25.4] [25.4] Face Area sq. ft. [sq. m].5 [.25].5 [.25].5 [.25].5 [.25] Rows / FPI [FPcm] / 2 [9] / 2 [9] / 2 [9] / 2 [9] Indoor Coil - Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m].5 [.25].5 [.25].5 [.25].5 [.25] Rows / FPI [FPcm] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] Refrigerant Control Orifices Orifices Orifices Orifices Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan - Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] /24 [609.6] /24 [609.6] /24 [609.6] /24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 4500 [224] 4500 [224] 4500 [224] 4500 [224] No. Motors/HP at /2 HP at /2 HP at /2 HP at /2 HP Motor RPM 075 075 075 075 Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] /5x5 [8x8] /5x5 [8x8] /5x5 [8x8] /5x5 [8x8] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 2 2 2 Motor RPM 725 725 725 725 Motor Frame Size 56 56 56 56 Filter - Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (NO.) Size Recommended in. [mm x mm x mm] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] Refrigerant Charge Oz. [g] 7.6 [4] 7.6 [4] 7.6 [4] 7.6 [4] Weights CONTINUED Net Weight lbs. [kg] 882 [40] 882 [40] 890 [404] 882 [40] Ship Weight lbs. [kg] 99 [47] 99 [47] 927 [420] 99 [47] See Page 7 for Notes.

GENERAL DATARLKL-B SERIES NOM. SIZES 7.5, 0, & 2.5 TON [26.4, 5.2 & 44.0 kw] ASHRAE 90.-200 COMPLIANT MODELS Model RLKL- Series B090YN B20CL B20CM B20DL Cooling Performance Gross Cooling Capacity Btu [kw] 87,000 [25.49] 2,000 [6.04] 2,000 [6.04] 2,000 [6.04] EER/SEER 2.2/NA.2/NA.2/NA.2/NA Nominal CFM/AHRI Rated CFM [L/s] 2800/2925 [2/80] 4000/600 [888/699] 4000/600 [888/699] 4000/600 [888/699] AHRI Net Cooling Capacity Btu [kw] 84,000 [24.6] 9,000 [4.87] 9,000 [4.87] 9,000 [4.87] Net Sensible Capacity Btu [kw] 64,800 [8.99] 87,200 [25.55] 87,200 [25.55] 87,200 [25.55] Net Latent Capacity Btu [kw] 9,200 [5.6],800 [9.2],800 [9.2],800 [9.2] IEER 2. 2.2 2.2 2.2 Net System Power kw 7.5 0.62 0.62 0.62 Compressor No./Type /Scroll /Scroll /Scroll /Scroll Outdoor Sound Rating (db) 4 88 88 88 88 Outdoor Coil - Fin Type Louvered Louvered Louvered Louvered Tube Type MicroChannel MicroChannel MicroChannel MicroChannel MicroChannel Depth in. [mm] [25.4] [25.4] [25.4] [25.4] Face Area sq. ft. [sq. m].5 [.25] 27 [2.5] 27 [2.5] 27 [2.5] Rows / FPI [FPcm] / 2 [9] / 2 [9] / 2 [9] / 2 [9] Indoor Coil - Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m].5 [.25].5 [.25].5 [.25].5 [.25] Rows / FPI [FPcm] 2 / 8 [7] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] Refrigerant Control Orifices Orifices Orifices Orifices Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan - Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] /24 [609.6] 2/24 [609.6] 2/24 [609.6] 2/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 4500 [224] 8400 [964] 8400 [964] 8400 [964] No. Motors/HP at /2 HP 2 at / HP 2 at / HP 2 at / HP Motor RPM 075 075 075 075 Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] /5x5 [8x8] /5x5 [8x8] /5x5 [8x8] /5x5 [8x8] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 2 2 Motor RPM 725 725 725 725 Motor Frame Size 56 56 56 56 Filter - Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (NO.) Size Recommended in. [mm x mm x mm] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] Refrigerant Charge Oz. [g] 7.6 [4] 204.8 [5806] 204.8 [5806] 204.8 [5806] Weights CONTINUED Net Weight lbs. [kg] 890 [404] 984 [446] 992 [450] 984 [446] Ship Weight lbs. [kg] 927 [420] 02 [46] 029 [467] 02 [46] See Page 7 for Notes. 2

GENERAL DATARLKL-B SERIES NOM. SIZES 7.5, 0, & 2.5 TON [26.4, 5.2 & 44.0 kw] ASHRAE 90.-200 COMPLIANT MODELS Model RLKL- Series B090YN B20CL B20CM B20DL Cooling Performance Gross Cooling Capacity Btu [kw] 87,000 [25.49] 2,000 [6.04] 2,000 [6.04] 2,000 [6.04] EER/SEER 2.2/NA.2/NA.2/NA.2/NA Nominal CFM/AHRI Rated CFM [L/s] 2800/2925 [2/80] 4000/600 [888/699] 4000/600 [888/699] 4000/600 [888/699] AHRI Net Cooling Capacity Btu [kw] 84,000 [24.6] 9,000 [4.87] 9,000 [4.87] 9,000 [4.87] Net Sensible Capacity Btu [kw] 64,800 [8.99] 87,200 [25.55] 87,200 [25.55] 87,200 [25.55] Net Latent Capacity Btu [kw] 9,200 [5.6],800 [9.2],800 [9.2],800 [9.2] IEER 2. 2.2 2.2 2.2 Net System Power kw 7.5 0.62 0.62 0.62 Compressor No./Type /Scroll /Scroll /Scroll /Scroll Outdoor Sound Rating (db) 4 88 88 88 88 Outdoor Coil - Fin Type Louvered Louvered Louvered Louvered Tube Type MicroChannel MicroChannel MicroChannel MicroChannel MicroChannel Depth in. [mm] [25.4] [25.4] [25.4] [25.4] Face Area sq. ft. [sq. m].5 [.25] 27 [2.5] 27 [2.5] 27 [2.5] Rows / FPI [FPcm] / 2 [9] / 2 [9] / 2 [9] / 2 [9] Indoor Coil - Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m].5 [.25].5 [.25].5 [.25].5 [.25] Rows / FPI [FPcm] 2 / 8 [7] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] Refrigerant Control Orifices Orifices Orifices Orifices Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan - Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] /24 [609.6] 2/24 [609.6] 2/24 [609.6] 2/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 4500 [224] 8400 [964] 8400 [964] 8400 [964] No. Motors/HP at /2 HP 2 at / HP 2 at / HP 2 at / HP Motor RPM 075 075 075 075 Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] /5x5 [8x8] /5x5 [8x8] /5x5 [8x8] /5x5 [8x8] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 2 2 Motor RPM 725 725 725 725 Motor Frame Size 56 56 56 56 Filter - Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (NO.) Size Recommended in. [mm x mm x mm] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] Refrigerant Charge Oz. [g] 7.6 [4] 204.8 [5806] 204.8 [5806] 204.8 [5806] Weights CONTINUED Net Weight lbs. [kg] 890 [404] 984 [446] 992 [450] 984 [446] Ship Weight lbs. [kg] 927 [420] 02 [46] 029 [467] 02 [46] See Page 7 for Notes.

GENERAL DATARLKL-B SERIES NOM. SIZES 7.5, 0, & 2.5 TON [26.4, 5.2 & 44.0 kw] ASHRAE 90.-200 COMPLIANT MODELS Model RLKL- Series B20DM B20YL B20YM B5CL Cooling Performance Gross Cooling Capacity Btu [kw] 2,000 [6.04] 2,000 [6.04] 2,000 [6.04] 56,000 [45.7] EER/SEER 2.2/NA.2/NA.2/NA./NA Nominal CFM/AHRI Rated CFM [L/s] 4000/600 [888/699] 4000/600 [888/699] 4000/600 [888/699] 5000/4225 [260/994] AHRI Net Cooling Capacity Btu [kw] 9,000 [4.87] 9,000 [4.87] 9,000 [4.87] 50,000 [4.95] Net Sensible Capacity Btu [kw] 87,200 [25.55] 87,200 [25.55] 87,200 [25.55] 06,600 [.2] Net Latent Capacity Btu [kw],800 [9.2],800 [9.2],800 [9.2] 4,400 [2.72] IEER 2.2 2.2 2.2 2. Net System Power [kw] 0.62 0.62 0.62.54 Compressor No./Type /Scroll /Scroll /Scroll 2/Scroll Outdoor Sound Rating (db) 4 88 88 88 88 Outdoor CoilFin Type Louvered Louvered Louvered Louvered Tube Type MicroChannel MicroChannel MicroChannel MicroChannel MicroChannel Depth in. [mm] [25.4] [25.4] [25.4] [25.4] Face Area sq. ft. [sq. m] 27 [2.5] 27 [2.5] 27 [2.5] 27 [2.5] Rows / FPI [FPcm] / 2 [9] / 2 [9] / 2 [9] 2 / 2 [9] Indoor CoilFin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m].5 [.25].5 [.25].5 [.25].5 [.25] Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] 4 / 5 [6] Refrigerant Control Orifices Orifices Orifices TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor FanType Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 2/24 [609.6] 2/24 [609.6] 2/24 [609.6] 2/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 8400 [964] 8400 [964] 8400 [964] 8000 [775] No. Motors/HP 2 at / HP 2 at / HP 2 at / HP 2 at /2 HP Motor RPM 075 075 075 075 Indoor FanType FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] /5x5 [8x8] /5x5 [8x8] /5x5 [8x8] /5x5 [8x8] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 2 Motor RPM 725 725 725 725 Motor Frame Size 56 56 56 56 FilterType Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm x mm x mm] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 204.8 [5806] 204.8 [5806] 204.8 [5806] 47.2/52 [47/409] Weights CONTINUED Net Weight lbs. [kg] 992 [450] 984 [446] 992 [450] 20 [558] Ship Weight lbs. [kg] 029 [467] 02 [46] 029 [467] 267 [575] See Page 7 for Notes. 4

GENERAL DATARLKL-B SERIES NOM. SIZES 7.5, 0, & 2.5 TON [26.4, 5.2 & 44.0 kw] ASHRAE 90.-200 COMPLIANT MODELS Model RLKL- Series B5CM B5DL B5DM B5YL Cooling Performance Gross Cooling Capacity Btu [kw] 56,000 [45.7] 56,000 [45.7] 56,000 [45.7] 56,000 [45.7] EER/SEER 2./NA./NA./NA./NA Nominal CFM/AHRI Rated CFM [L/s] 5000/4225 [260/994] 5000/4225 [260/994] 5000/4225 [260/994] 5000/4225 [260/994] AHRI Net Cooling Capacity Btu [kw] 50,000 [4.95] 50,000 [4.95] 50,000 [4.95] 50,000 [4.95] Net Sensible Capacity Btu [kw] 06,600 [.2] 06,600 [.2] 06,600 [.2] 06,600 [.2] Net Latent Capacity Btu [kw] 4,400 [2.72] 4,400 [2.72] 4,400 [2.72] 4,400 [2.72] IEER 2. 2. 2. 2. Net System Power kw.54.54.54.54 Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 4 88 88 88 88 Outdoor Coil - Fin Type Louvered Louvered Louvered Louvered Tube Type MicroChannel MicroChannel MicroChannel MicroChannel MicroChannel Depth in. [mm] [25.4] [25.4] [25.4] [25.4] Face Area sq. ft. [sq. m] 27 [2.5] 27 [2.5] 27 [2.5] 27 [2.5] Rows / FPI [FPcm] 2 / 2 [9] 2 / 2 [9] 2 / 2 [9] 2 / 2 [9] Indoor Coil - Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m].5 [.25].5 [.25].5 [.25].5 [.25] Rows / FPI [FPcm] 4 / 5 [6] 4 / 5 [6] 4 / 5 [6] 4 / 5 [6] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan - Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 2/24 [609.6] 2/24 [609.6] 2/24 [609.6] 2/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 8000 [775] 8000 [775] 8000 [775] 8000 [775] No. Motors/HP 2 at /2 HP 2 at /2 HP 2 at /2 HP 2 at /2 HP Motor RPM 075 075 075 075 Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] /5x5 [8x8] /5x5 [8x8] /5x5 [8x8] /5x5 [8x8] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 5 5 Motor RPM 725 725 725 725 Motor Frame Size 84 56 84 56 Filter - Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (NO.) Size Recommended in. [mm x mm x mm] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] (6)2x8x8 [5x457x457] Refrigerant Charge Oz. [g] 47.2/52 [47/409] 47.2/52 [47/409] 47.2/52 [47/409] 47.2/52 [47/409] Weights CONTINUED Net Weight lbs. [kg] 28 [562] 20 [558] 28 [562] 20 [558] Ship Weight lbs. [kg] 275 [578] 267 [575] 275 [578] 267 [575] See Page 7 for Notes. 5

GENERAL DATARLKL-B SERIES NOM. SIZES 7.5, 0, & 2.5 TON [26.4, 5.2 & 44.0 kw] ASHRAE 90.-200 COMPLIANT MODELS Model RLKL- Series Cooling Performance B5YM Gross Cooling Capacity Btu [kw] 56,000 [45.7] EER/SEER 2./NA Nominal CFM/AHRI Rated CFM [L/s] 5000/4225 [260/994] AHRI Net Cooling Capacity Btu [kw] 50,000 [4.95] Net Sensible Capacity Btu [kw] 06,600 [.2] Net Latent Capacity Btu [kw] 4,400 [2.72] IEER 2. Net System Power kw.54 Compressor No./Type 2/Scroll Outdoor Sound Rating (db) 4 88 Outdoor CoilFin Type Tube Type Louvered MicroChannel Tube Size in. [mm] OD [25.4] Face Area sq. ft. [sq. m] 27 [2.5] Rows / FPI [FPcm] 2 / 2 [9] Indoor CoilFin Type Tube Type Louvered Rifled Tube Size in. [mm] 0.75 [9.5] Face Area sq. ft. [sq. m].5 [.25] Rows / FPI [FPcm] 4 / 5 [6] Refrigerant Control TX Valves Drain Connection No./Size in. [mm] / [25.4] Outdoor FanType Propeller No. Used/Diameter in. [mm] 2/24 [609.6] Drive Type/No. Speeds Direct/ CFM [L/s] 8000 [775] No. Motors/HP 2 at /2 HP Motor RPM 075 Indoor FanType No. Used/Diameter in. [mm] Drive Type/No. Speeds FC Centrifugal /5x5 [8x8] Belt/Variable No. Motors Motor HP 5 Motor RPM 725 Motor Frame Size 84 FilterType Furnished (No.) Size Recommended in. [mm] Disposable Yes (6)2x8x8 [5x457x457] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 47.2/52 [47/409] Weights Net Weight lbs. [kg] 28 [562] Ship Weight lbs. [kg] 275 [578] See Page 7 for Notes. 6

NOTES: GENERAL DATARLKL-B SERIES. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 40/60. 2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures.. IEER is rated in accordance with AHRI Standard 40/60. Units are rated at 80 F ambient, 80 F entering dry bulb, and 67 F entering wet bulb at AHRI rated cfm. 4. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270. 7

SYSTEMS PERFORMANCERLKL-B SERIES GROSS SYSTEMS PERFORMANCE DATAB090 O UT D O O R D R Y B U LB T E M PE R AT U R E F [ C] 75 [2.9] 80 [26.7] 85 [29.4] 90 [2.2] 95 [5] 00 [7.8] 05 [40.6] 0 [4.] 5 [46.] ENTERING INDOOR AIR @ 80 F [26.7 C] dbe ➀ wbe 7 F [2.7 C] 67 F [9.4 C] 6 F [7.2 C] CFM [L/s] 600 [699] 2925 [80] 2400 [] 600 [699] 2925 [80] 2400 [] 600 [699] 2925 [80] 2400 [] DR ➀.05.09..05.09..05.09. Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power 06. [.2] 7. [2.5] 5.7 04.4 [0.6] 72.6 [2.] 6.0 02.0 [29.9] 7. [20.9] 6. 99. [29.] 69.9 [20.5] 6.6 96.2 [28.2] 68. [20.0] 6.9 92.7 [27.2] 66.0 [9.4] 7. 88.9 [26.] 6.7 [8.7] 7.6 84.7 [24.8] 6.0 [7.9] 8.0 80. [2.5] 58.0 [7.0] 8.4 02. [29.9] 62.0 [8.2] 5.5 00.2 [29.4] 6. [8.0] 5.8 97.9 [28.7] 60. [7.7] 6. 95. [27.9] 59. [7.] 6.5 92. [27.] 57.6 [6.9] 6.8 89.0 [26.] 55.9 [6.4] 7. 85. [25.0] 5.9 [5.8] 7.5 8. [2.8] 5.7 [5.2] 7.9 76.9 [22.5] 49.2 [4.4] 8. 98.7 [28.9] 5.7 [5.7] 5.5 96.9 [28.4] 5. [5.6] 5.7 94.7 [27.8] 52. [5.] 6.0 92.2 [27.0] 5. [5.0] 6.4 89. [26.2] 50.0 [4.7] 6.7 86. [25.2] 48.6 [4.] 7.0 82.5 [24.2] 46.8 [.7] 7.4 78.7 [2.] 45.0 [.2] 7.7 74.4 [2.8] 42.8 [2.6] 8. 00.6 [29.5] 84. [24.7] 5.6 98.6 [28.9] 8. [24.4] 5.8 96. [28.2] 82.2 [24.] 6.2 9.5 [27.4] 80.6 [2.6] 6.5 90.5 [26.5] 79.0 [2.2] 6.8 87.0 [25.5] 76.9 [22.5] 7.2 8.2 [24.4] 74.5 [2.8] 7.5 79.0 [2.2] 7.9 [2.] 7.9 74.4 [2.8] 68.9 [20.2] 8. GROSS SYSTEMS PERFORMANCE DATAB20 O UT D O O R D R Y B U LB T E M PE R AT U R E F [ C] 75 [2.9] 80 [26.7] 85 [29.4] 90 [2.2] 95 [5] 00 [7.8] 05 [40.6] 0 [4.] 5 [46.] 96.5 [28.] 72.0 [2.] 5.4 94.6 [27.7] 7.2 [20.9] 5.7 92.4 [27.] 70. [20.6] 6.0 89.8 [26.] 69. [20.] 6. 86.8 [25.4] 67.6 [9.8] 6.7 8.5 [24.5] 65.9 [9.] 7.0 79.8 [2.4] 6.9 [8.7] 7.4 75.8 [22.2] 6.7 [8.] 7.8 7.4 [20.9] 59.2 [7.4] 8.2 9.4 [27.4] 6. [8.5] 5.4 9.6 [26.8] 62.5 [8.] 5.6 89.4 [26.2] 6.7 [8.] 5.9 86.8 [25.4] 60.6 [7.8] 6.2 84.0 [24.6] 59.4 [7.4] 6.6 80.8 [2.7] 57.9 [7.0] 6.9 77.2 [22.6] 56.2 [6.5] 7. 7. [2.5] 54.2 [5.9] 7.6 69. [20.] 52. [5.] 8.0 97. [28.5] 94.8 [27.8] 5.4 95. [27.9] 9.9 [27.5] 5.7 9.0 [27.] 92.8 [27.2] 6.0 90. [26.5] 90. [26.5] 6.4 87.2 [25.6] 87.2 [25.6] 6.7 8.7 [24.5] 8.7 [24.5] 7. 79.9 [2.4] 79.9 [2.4] 7.4 75.7 [22.2] 75.7 [22.2] 7.8 7. [20.8] 7. [20.8] 8.2 9.4 [27.4] 8.7 [24.0] 5. 9.5 [26.8] 8.0 [2.7] 5.6 89.2 [26.] 80.0 [2.5] 5.9 86.6 [25.4] 78.7 [2.] 6.2 8.7 [24.5] 77. [22.7] 6.6 80. [2.5] 75.5 [22.] 6.9 76.7 [22.5] 7.6 [2.6] 7. 72.6 [2.] 7. [20.9] 7.7 68. [20.0] 68. [20.0] 8. 90.4 [26.5] 72. [2.] 5.2 88.5 [25.9] 7.5 [2.0] 5.5 86. [25.] 70.6 [20.7] 5.8 8.8 [24.6] 69.5 [20.4] 6. 80.9 [2.7] 68. [20.0] 6.5 77.7 [22.8] 66.8 [9.6] 6.8 74.2 [2.7] 65. [9.] 7.2 70. [20.6] 6.2 [8.5] 7.5 66.0 [9.] 6. [7.9] 7.9 ENTERING INDOOR AIR @ 80 F [26.7 C] dbe ➀ wbe 7 F [2.7 C] 67 F [9.4 C] 6 F [7.2 C] CFM [L/s] 4800 [2265] 600 [699] 200 [50] 4800 [2265] 600 [699] 200 [50] 4800 [2265] 600 [699] 200 [50] DR ➀.0.04.07.0.04.07.0.04.07 Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power DR Depression ratio dbe Entering air dry bulb wbeentering air wet bulb 5.4 [45.0] 05.0 [0.8] 7.8 50.0 [44.0] 0.2 [0.] 8.2 46. [42.9] 0. [29.6] 8.6 42.2 [4.7] 98.9 [29.0] 9.0 7.7 [40.4] 96.4 [28.] 9.4 2.8 [8.9] 9.6 [27.4] 9.9 27.6 [7.4] 90.7 [26.6] 0.4 2.9 [5.7] 87.4 [25.6] 0.9 5.9 [4.0] 84.0 [24.6].4 44.6 [42.4] 82. [24.] 7.6 4.5 [4.5] 80.8 [2.7] 8.0 8.0 [40.4] 79.2 [2.2] 8. 4. [9.] 77.5 [22.7] 8.7 29.8 [8.0] 75.5 [22.] 9.2 25.2 [6.7] 7.4 [2.5] 9.6 20. [5.] 7.2 [20.9] 0. 5.0 [.7] 68.7 [20.] 0.6 09. [2.0] 66. [9.4]. 4.7 [4.5] 75. [22.0] 7.5 8.6 [40.6] 7.9 [2.7] 7.9 5.2 [9.6] 72.4 [2.2] 8..4 [8.5] 70.9 [20.8] 8.7 27.2 [7.] 69. [20.] 9. 22.7 [6.0] 67.2 [9.7] 9.5 7.9 [4.6] 65.2 [9.] 0.0 2.6 [.0] 62.9 [8.4] 0.5 07. [.4] 60.6 [7.8].0 Total Total capacity x 000 BTUH Sens Sensible capacity x 000 BTUH PowerKW input 46.5 [42.9] 2. [6.] 7.6 4.2 [42.0] 2. [5.6] 8.0 9.5 [40.9] 9. [5.0] 8.4 5.4 [9.7] 7. [4.] 8.8 0.9 [8.4] 4.5 [.6] 9.2 26.0 [6.9].7 [2.7] 9.7 20.7 [5.4] 08.7 [.9] 0.2 5. [.7] 05.5 [0.9] 0.7 09.0 [.9] 02.0 [29.9].2 8.2 [40.5] 98.2 [28.8] 7.4 5.0 [9.6] 96.8 [28.4] 7.8.5 [8.5] 95.2 [27.9] 8.2 27.6 [7.4] 9.5 [27.4] 8.6 2.4 [6.2] 9.6 [26.9] 9.0 8.8 [4.8] 89.5 [26.2] 9.4.8 [.4] 87.2 [25.6] 9.9 08.5 [.8] 84.7 [24.8] 0.4 02.8 [0.] 82. [24.] 0.9 5.4 [9.7] 90.5 [26.5] 7. 2. [8.8] 89.2 [26.2] 7.7 28.8 [7.7] 87.7 [25.7] 8. 25.0 [6.6] 86.2 [25.] 8.5 20.9 [5.4] 84.5 [24.8] 8.9 6.4 [4.] 82.6 [24.2] 9..5 [2.7] 80.5 [2.6] 9.8 06. [.2] 78.2 [22.9] 0. 00.7 [29.5] 75.9 [22.] 0.8 4.4 [4.4] 40. [4.] 7.4 8.0 [40.4] 8.0 [40.5] 7.8 4. [9.4] 4. [9.4] 8.2 0.2 [8.2] 0.2 [8.2] 8.6 25.7 [6.8] 25.7 [6.8] 9.0 20.8 [5.4] 20.8 [5.4] 9.5 5.6 [.9] 5.6 [.9] 0.0 09.9 [2.2] 09.9 [2.2] 0.5 0.9 [0.5] 0.9 [0.5].0. [9.]. [.2] 7.2 0.2 [8.2].8 [2.8] 7.6 26.6 [7.] 0.2 [2.] 8.0 22.8 [6.0] 08.5 [.8] 8.4 8.5 [4.7] 06.6 [.] 8.8.9 [.4] 04.5 [0.6] 9.2 09.0 [.9] 02.2 [0.0] 9.7 0.6 [0.4] 99.7 [29.2] 0.2 98.0 [28.7] 97. [28.5] 0.7 0.6 [8.] 04.7 [0.7] 7.2 27.5 [7.4] 0.4 [0.] 7.5 24. [6.4] 02. [29.9] 7.9 20. [5.] 00.5 [29.5] 8. 6. [4.0] 98.8 [29.0] 8.7.6 [2.7] 96.9 [28.4] 9. 06.8 [.] 94.8 [27.8] 9.6 0.5 [29.7] 92.5 [27.] 0. 96.0 [28.] 90.2 [26.4] 0.6 NOTES: ➀ When the entering air dry bulb is other than 80 F [27 C], adjust the sensible capacity from the table by adding [.0 x CFM x ( DR) x (dbe 80)]. 8

SYSTEMS PERFORMANCERLKL-B SERIES GROSS SYSTEMS PERFORMANCE DATAB5 O UT D O O R D R Y B U LB T E M PE R AT U R E F [ C] 75 [2.9] 80 [26.7] 85 [29.4] 90 [2.2] 95 [5] 00 [7.8] 05 [40.6] 0 [4.] 5 [46.] ENTERING INDOOR AIR @ 80 F [26.7 C] ➀ wbe 7 F [2.7 C] 67 F [9.4 C] 6 F [7.2 C] CFM [L/s] 5800 [277] 4225 [994] 800 [79] 5800 [277] 4225 [994] 800 [79] 5800 [277] 4225 [994] 800 [79] DR ➀ 0.0.06 0.0.06 0.0.06 Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power Total BTUH [kw] Sens BTUH [kw] Power DR Depression ratio dbe Entering air dry bulb wbeentering air wet bulb 96.8 [57.7] 5.5 [9.7] 0.2 92. [56.] 2.7 [8.9] 0.7 87.2 [54.9] 29.7 [8.0].2 82. [5.4] 26.8 [7.2].8 76.8 [5.8] 2.6 [6.2] 2. 7. [50.2] 20. [5.].0 65.6 [48.5] 6.9 [4.].6 59.7 [46.8].4 [.2] 4. 5.6 [45.0] 09.8 [2.2] 5.0 84.4 [54.0] 0.0 [0.2] 9.9 79.9 [52.7] 00.8 [29.6] 0. 75. [5.4] 98.6 [28.9] 0.9 70.5 [50.0] 96.4 [28.].4 65.6 [48.5] 94. [27.6].9 60.4 [47.0] 9.6 [26.9] 2.5 55. [45.5] 89. [26.].2 49.6 [4.8] 86.5 [25.4].8 4.9 [42.2] 8.8 [24.6] 4.5 8.0 [5.0] 94.9 [27.8] 9.8 76.6 [5.8] 92.9 [27.2] 0. 72. [50.4] 90.9 [26.7] 0.8 67.4 [49.] 88.9 [26.]. 62.5 [47.6] 86.7 [25.4].8 57.5 [46.2] 84.5 [24.8] 2.4 52.2 [44.6] 82.2 [24.].0 46.8 [4.0] 79.8 [2.4].7 4.2 [4.4] 77. [22.7] 4.4 Total Total capacity x 000 BTUH Sens Sensible capacity x 000 BTUH PowerKW input 86.8 [54.7] 56.7 [45.9] 0.0 82. [5.4] 5.9 [45.] 0.5 77.2 [5.9] 5. [44.].0 72. [50.4] 48.0 [4.4].5 66.8 [48.9] 44.9 [42.5] 2. 6. [47.] 4.6 [4.5] 2.7 55.6 [45.6] 8.2 [40.5].4 49.7 [4.9] 4.7 [9.5] 4.0 4.6 [42.].0 [8.4] 4.7 75.0 [5.] 2.7 [5.7] 9.7 70.6 [50.0] 9.6 [5.] 0. 66.0 [48.6] 7.5 [4.4] 0.6 6.2 [47.2] 5.2 [.8].2 56.2 [45.8] 2.8 [.].7 5.0 [44.] 0. [2.] 2. 45.7 [42.7] 07.8 [.6] 2.9 40.2 [4.] 05.2 [0.8].6 4.5 [9.4] 02.5 [0.0] 4. 7.8 [50.] 2.9 [.] 9.6 67.4 [49.] 0.9 [2.5] 0.0 62.9 [47.7] 09.0 [2.0] 0.5 58.2 [46.4] 06.9 [.]. 5. [44.9] 04.7 [0.7].6 48. [4.5] 02.5 [0.0] 2.2 4.0 [4.9] 00.2 [29.4] 2.8 7.6 [40.] 97.8 [28.7].5 2.0 [8.7] 95. [27.9] 4.2 78.6 [52.] 77.9 [52.] 9.7 7.9 [5.0] 7.9 [5.0] 0.2 69.0 [49.5] 69.0 [49.5] 0.7 6.9 [48.0] 6.9 [48.0]. 58.6 [46.5] 58.6 [46.5].9 5. [44.9] 5. [44.9] 2.5 47.4 [4.2] 47.4 [4.2]. 4.5 [4.5] 4.5 [4.5].8 5.4 [9.7] 5.4 [9.7] 4.5 67. [49.0] 40.2 [4.] 9.4 62.9 [47.7] 8.2 [40.5] 9.9 58. [46.4] 6.0 [9.9] 0.4 5.5 [45.0].7 [9.2] 0.9 48.5 [4.5]. [8.5].5 4. [42.0] 28.8 [7.8] 2. 8.0 [40.4] 26. [7.0] 2.7 2.5 [8.8] 2.7 [6.].4 26.8 [7.2] 2.0 [5.5] 4. 64.2 [48.] 0.7 [8.] 9. 59.9 [46.9] 28.9 [7.8] 9.8 55.4 [45.5] 26.9 [7.2] 0. 50.7 [44.2] 24.8 [6.6] 0.8 45.8 [42.7] 22.6 [5.9].4 40.7 [4.2] 20. [5.] 2.0 5.5 [9.7] 8.0 [4.6] 2.6 0. [8.] 5.6 [.9]. 24.5 [6.5]. [.2].9 NOTES: ➀ When the entering air dry bulb is other than 80 F [27 C], adjust the sensible capacity from the table by adding [.0 x CFM x ( DR) x (dbe 80)]. 9

AIRFLOW PERFORMANCERLKL-B SERIES AIRFLOW PERFORMANCE7.5 TON [26.4 kw] (B090) Capacity 7.5 Ton [26.4 kw] Air External Static PressureInches of Water [kpa] Flow 0. [.02] 0.2 [.05] 0. [.07] 0.4 [.0] 0.5 [.2] 0.6 [.5] 0.7 [.7] 0.8 [.20] 0.9 [.22].0 [.25]. [.27].2 [.0]. [.2].4 [.5].5 [.7].6 [.40].7 [.42].8 [.45].9 [.47] 2.0 [.50] CFM [L/s] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W 2400 [] 540 580 582 664 62 729 645 82 7 890 740 952 770 04 799 076 828 8 857 200 887 26 929 58 958 62 987 709 07 794 046 879 075 965 05 2050 2500 [80] 552 6 59 77 624 79 656 878 720 950 749 02 778 074 808 6 87 98 866 260 895 22 96 602 965 687 995 77 024 858 05 944 08 2029 2 24 2600 [227] 564 687 60 769 65 85 667 945 729 00 758 072 787 4 86 96 846 258 875 20 94 58 94 666 972 75 002 87 0 922 06 2008 090 209 9 278 2700 [274] 59 670 577 744 64 828 648 92 680 07 77 070 766 2 796 94 825 256 854 8 88 80 92 645 950 70 980 86 009 90 08 986 068 2072 097 257 27 224 2800 [2] 554 7 590 80 625 887 660 99 708 069 746 775 92 804 254 84 6 86 78 892 440 928 709 958 794 987 880 06 965 046 2050 075 26 04 222 4 207 2900 [69] 569 80 604 866 68 956 67 069 725 29 755 9 784 25 8 5 842 76 872 48 906 688 96 77 965 858 994 944 024 2029 05 25 082 2200 2 2285 4 27 000 [46] 546 74 854 869 67 9 650 024 685 44 74 89 76 25 792 822 75 85 47 880 498 9 752 94 87 972 92 002 2008 0 209 060 279 090 2264 9 250 48 245 00 [46] 560 804 598 940 62 00 664 07 7 87 74 249 772 80 7 80 45 860 497 889 559 92 86 950 90 979 987 009 2072 08 257 068 224 097 228 26 244 56 2499 200 [50] 576 876 62 0 646 089 678 89 722 247 75 09 78 7 80 4 89 495 868 557 898 69 928 880 957 965 987 205 06 26 045 2222 075 207 04 292 4 2478 6 256 00 [557] 592 954 628 096 660 68 692 274 7 07 760 69 789 4 88 49 848 555 877 67 906 859 95 944 965 2029 994 25 02 2200 05 2286 082 27 2456 4 2542 70 2627 400 [605] 607 00 64 80 67 247 70 06 79 68 769 40 798 49 827 55 856 65 886 677 9 92 94 2008 972 2094 00 279 0 2264 060 250 089 245 9 252 48 2606 78 269 500 [652] 622 2 658 27 689 44 79 66 748 428 777 490 807 552 86 6 865 675 894 77 920 987 950 2072 979 258 009 224 08 228 067 244 097 2499 26 2585 55 2670 85 2756 600 [699] 68 202 672 6 704 440 728 426 757 488 786 550 85 62 844 674 874 75 90 797 928 205 957 26 986 2222 06 207 045 29 075 2478 04 256 2649 6 274 92 2820 Drive Package L M Motor H.P. [W] 2.0 [49.4] 2.0 [49.4] Blower Sheave BK0 BK90 Motor Sheave VP-44 VP-44 Turns Open 2 4 5 6 2 4 5 6 RPM 682 650 620 587 555 52 869 88 806 774 742 70 NOTES:. Factory sheave settings are shown in bold print. 2. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum E.S.P.. Do not operate above blower RPM shown as motor overloading will occur. 4. Do not set motor sheave below one turn open. N.0 [227.] BK65 VP-44 2 4 5 6 57 06 056 005 954 904 AIRFLOW CORRECTION FACTORS 7.5 TON [26.4 kw] (B090) ACTUALCFM [L/s] 2600 [227] 2800 [2] 000 [46] 200 [50] 400 [605] TOTAL MBH 0.97 0.98 0.99.00.0 SENSIBLE MBH 0.9 0.94 0.97.00.02 POWER kw 0.99 0.99 0.99.00.00 NOTES:. Multiply correction factor times gross performance data. 2. Resulting sensible capacity cannot exceed total capacity. 600 [699].02.05.0 800 [79].0.08.02 COMPONENT AIR RESISTANCE, IWC 7.5 TON [26.4 kw] (B090) Wet Coil Component Concentric Diffuser RXRN-FA65 or FA75 & Transition RXMC-CD04 Concentric Diffuser RXRN-AA6 or AA7 & Transition RXMC-CE05 Economizer 00% R.A. Damper Open Horizontal Economizer 00% R.A. Damper Open Horizontal Economizer 00% O.A. Damper Open 2400 [] 0.047 [0.02] DNA 0.05 [0.02] 0.0 [0.007] 0.08 [0.020] 2600 [227] 0.05 [0.0].07 [0.042] 0.06 [0.05] 0.04 [0.009] 0.08 [0.020] Standard Indoor AirflowCFM [L/s] 2800 [2] 000 [46] 200 [50] ResistanceInches Water [kpa] 0.055 [0.04].020 [0.050] 0.07 [0.07] 0.04 [0.00] 0.08 [0.020] 0.060 [0.05].025 [0.062] 0.08 [0.020] 0.05 [0.0] 0.0 [0.024] 0.065 [0.06].0 [0.077] 0.09 [0.022] 0.05 [0.02] 0. [0.027] 400 [604] 0.07 [0.08].07 [0.092] DNA DNA DNA DNA DNA DNA NOTE: Add component resistance to duct resistance to determine total external static pressure. DNA = Data not Available. 0.0 [0.025] 0.06 [0.04] 0.2 [0.00] 600 [699] 0.076 [0.09] DNA.07 [0.042] 0. [0.027] 0.06 [0.05] 0. [0.02] 20

AIRFLOW PERFORMANCERLKL-B SERIES AIRFLOW PERFORMANCE0 TON [5.2 kw] (B20) Air Flow CFM [L/s] Capacity 0 Ton [5.2 kw] External Static PressureInches of Water [kpa] 0. [.02] 0.2 [.05] 0. [.07] 0.4 [.0] 0.5 [.2] 0.6 [.5] 0.7 [.7] 0.8 [.20] 0.9 [.22].0 [.25]. [.27].2 [.0]. [.2].4 [.5].5 [.7] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W 200 [50] 657 70 75 245 742 9 770 94 797 468 825 54 852 67 880 692 956 698 976 70 996 87 07 90 00 [557] 67 79 70 25 728 28 756 402 78 477 8 55 88 626 866 700 94 705 96 708 948 822 976 95 024 2049 400 [605] 687 26 74 6 742 40 769 485 797 559 824 64 852 708 879 76 950 8 97 827 962 94 989 2054 02 268 500 [652] 67 270 700 44 728 49 755 49 78 588 80 642 88 77 865 79 98 8 958 82 978 946 975 2059 00 27 09 2286 600 [699] 686 52 74 427 74 50 769 576 796 650 824 725 85 799 879 874 945 892 966 95 986 2065 989 278 06 2292 047 2405 700 [746] 672 6 700 45 727 50 755 584 782 659 80 7 87 808 865 882 9 896 95 956 97 2070 99 28 002 2297 00 240 054 2524.6 [.40].7 [.42].8 [.45] 07 2044 057 257 077 227 044 262 065 2276 085 290 052 228 072 295 092 2508 059 2400 080 25 00 2627 067 259 087 262 08 2746 075 267 095 275 5 2864.9 [.47] 2.0 [.50] 2. [.52] 2.2 [.55] 2. [.57] RPM W RPM W RPM W RPM W 098 284 8 2498 05 250 25 267 2622 275 20 2740 4 2854 28 2859 48 297 5 2978 56 09 8 26 59 2725 79 288 46 270 66 2844 86 2957 5 2849 74 2962 94 076 6 2968 8 08 68 086 89 200 76 205 96 8 800 [79] 686 44 7 58 74 592 768 667 796 74 82 88 86 890 878 965 940 200 960 2075 98 289 00 202 06 246 04 2529 062 264 082 2756 02 2870 2 298 4 097 6 20 8 24 900 [84] 699 526 727 60 754 675 782 750 809 824 87 899 864 97 927 205 948 2080 968 294 988 207 008 242 029 254 057 2648 069 276 090 2875 0 2988 0 02 50 25 7 29 9 442 4000 [888] 7 609 740 68 768 758 795 82 82 907 850 96 878 2056 95 2085 955 299 975 22 996 2426 06 259 04 265 070 2767 077 2880 097 2994 7 07 8 22 58 4 78 448 99 56 400 [95] 726 692 754 766 78 84 809 95 86 990 864 2064 922 209 942 2204 96 28 98 24 00 2545 024 2658 056 2772 084 2885 084 2999 05 2 25 226 45 9 66 45 86 566 4200 [982] 740 774 767 849 795 92 822 998 850 2072 877 247 90 2209 950 22 970 248 990 2550 0 266 0 2777 070 2890 097 004 092 7 2 2 45 5 458 7 572 9 685 400 [2029] 75 857 78 92 808 2006 86 208 85 255 97 225 97 228 957 2442 978 2555 998 2669 08 2782 09 2896 08 009 2 099 26 20 50 40 45 60 577 8 690 4400 [2077] 767 940 794 204 822 2089 849 26 877 228 924 2 945 2447 965 2560 985 2674 006 2787 026 290 046 04 097 28 24 24 07 55 27 468 48 582 68 695 88 809 4500 [224] 780 202 808 2097 85 272 86 2248 92 28 92 2452 952 2585 97 2679 99 279 0 2906 0 020 054 0 247 8 60 5 474 5 587 55 70 75 84 96 928 4600 [27] 794 205 82 280 840 2254 876 229 99 2457 940 257 960 2684 980 2798 000 29 02 025 04 8 06 252 24 65 5 479 22 592 42 706 6 89 8 9 4700 [228] 807 288 85 226 862 27 906 2462 927 2576 947 2689 967 280 988 296 008 00 028 4 048 257 069 7 7 484 65 598 0 7 50 825 70 98 90 4052 4800 [2265] 82 227 848 245 876 2420 94 258 94 2695 955 2808 975 2922 995 05 05 49 06 262 056 76 076 489 5 60 78 76 7 80 57 94 78 4057 98 470 NOTE: L-Drive left of bold line, M-Drive right of bold line. Drive Package L M Motor H.P. [W] 2.0 [49.4].0 [227.] Blower Sheave BK90 BK65 Motor Sheave VP-44 VP-44 Turns Open 2 4 5 6 2 4 5 6 RPM 845 80 775 79 704 669 8 089 04 992 94 894 NOTES:. Factory sheave settings are shown in bold print. 2. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum E.S.P.. Do not operate above blower RPM shown as motor overloading will occur. 4. Do not set motor sheave below one turn open. AIRFLOW CORRECTION FACTORS 0 TON [5.2 kw] (B20) ACTUALCFM [L/s] 200 [50] 400 [605] 600 [699] 800 [79] 4000 [888] 4200 [982] TOTAL MBH 0.96 0.97 0.98 0.99.00.0 SENSIBLE MBH 0.9 0.9 0.95 0.97.00.02 POWER kw 0.98 0.98 0.99 0.99.00.00 NOTES:. Multiply correction factor times gross performance data. 2. Resulting sensible capacity cannot exceed total capacity. 4400 [2077].02.05.0 4600 [27].0.07.0 4800 [2265].04.09.0 COMPONENT AIR RESISTANCE, IWC 0 TON [5.2 kw] (B20) Wet Coil Component Concentric Diffuser RXRN-FA65 or FA75 & Transition RXMC-CD04 Concentric Diffuser RXRN-AA6 or AA7 & Transition RXMC-CE05 Concentric Diffuser RXRN-AA66 or AA76 & Transition RXMC-CF06 Economizer 00% R.A. Damper Open Horizontal Economizer 00% R.A. Damper Open Horizontal Economizer 00% O.A. Damper Open 200 [50] 0.065 [0.06] 0. [0.077] DNA 0.09 [0.022] 0.05 [0.02] 0. [0.027] 400 [604] 0.07 [0.08] 0.7 [0.092] DNA 0.0 [0.025] 0.06 [0.04] 0.2 [0.00] 600 [699] Standard Indoor AirflowCFM [L/s] 800 [79] 4000 [888] 4200 [982] ResistanceInches Water [kpa] 0.076 [0.09] 4400 [2076] DNA DNA DNA DNA DNA 0.7 [0.042] 0. [0.027] 0.06 [0.05] 0. [0.02] 0.082 [0.020] 0.8 [0.045] 0.2 [0.00] 0.07 [0.07] 0.5 [0.0.6] 0.087 [0.022] 0.2 [0.052] 0. [0.02] 0.08 [0.020] 0.6 [0.040] 0.09 [0.02] 0.24 [0.060] 0.4 [0.05] 0.09 [0.02] 0.8 [0.044] 0.099 [0.025] 0.27 [0.067] DNA DNA DNA DNA DNA DNA DNA NOTE: Add component resistance to duct resistance to determine total external static pressure. DNA = Data not Available. 0.5 [0.07] 0.09 [0.022] 0.9 [0.047] 4600 [27] 0.05 [0.026] DNA DNA 0. [0.077] 0.6 [0.040] 0.0 [0.024] 0.20 [0.50] 4800 [2265] 0.0 [0.027] DNA DNA 0.2 [0.080] 0.7 [0.042] 0.0 [0.025] 0.2 [0.052] 2

AIRFLOW PERFORMANCERLKL-B SERIES AIRFLOW PERFORMANCE2.5 TON [44.0 kw] (B5) Air Flow CFM [L/s] Model RLKL-B5 Voltage 208/20, 460, 575 phase 60 Hz External Static PressureInches of Water [kpa] 0. [.02] 0.2 [.05] 0. [.07] 0.4 [.0] 0.5 [.2] 0.6 [.5] 0.7 [.7] 0.8 [.20] 0.9 [.22].0 [.25]. [.27].2 [.0]. [.2].4 [.5].5 [.7].6 [.40].7 [.42].8 [.45].9 [.47] 2.0 [.50] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W 800 [79] 828 605 854 66 879 722 904 786 929 85 954 924 979 998 004 2075 028 256 052 224 076 228 099 2420 4000 [888] 80 75 855 796 880 859 905 927 90 997 955 2072 979 249 004 220 028 25 052 240 075 2494 099 2589 22 2687 4200 [982] 82 877 858 94 88 2008 908 2079 92 25 957 220 98 22 005 296 029 2484 05 2575 076 2670 099 2769 22 2870 45 2975 4400 [2076] 86 2029 862 2096 886 267 9 224 96 29 960 2400 984 2485 008 257 0 2664 055 2759 078 2858 0 2959 24 065 46 7 69 285 4600 [27] 867 226 89 27 96 245 940 2496 964 258 988 2669 02 2760 05 2855 058 2954 08 056 04 6 27 270 49 82 7 497 9 66 4800 [2265] 897 258 922 2599 946 2684 970 2772 99 2864 07 2959 040 057 06 59 086 265 08 7 485 5 60 75 720 96 84 28 969 5000 [259] 929 2795 95 288 976 2975 000 070 02 68 046 270 069 75 09 484 4 597 6 72 58 8 79 954 20 4080 222 4209 244 442 5200 [2454] 96 09 984 88 007 286 00 88 05 494 076 60 098 75 20 8 42 950 64 4072 86 499 207 428 228 446 249 4597 270 477 5400 [2548] 99 42 06 54 09 69 062 728 084 84 06 956 28 4076 50 498 7 424 9 4454 24 4587 25 472 256 486 276 5007 296 55 5600 [264] 026 752 049 86 07 974 09 4089 5 4209 7 4 59 4458 80 4587 20 4720 222 4857 24 4997 26 540 284 5287 5800 [277] 060 44 082 420 04 449 26 4472 47 4598 69 4728 90 486 2 4997 22 57 252 528 272 5428 292 5578 NOTE: L-Drive left of bold line, M-Drive right of bold line. RPM W RPM W RPM W 2 254 46 26 69 274 45 2789 68 2894 90 002 68 084 90 96 22 2 9 40 2 520 25 642 25 79 26 865 258 994 29 4098 26 42 282 467 264 4479 285 468 290 4880 RPM W RPM W 92 289 25 2928 2 4 25 20 24 40 256 55 256 768 278 897 279 427 00 426 Drive Package L M Motor H.P. [W].0 [227.] 5.0 [728.5] Blower Sheave BK72H BK85H Motor Sheave VP-44 VP-65 Turns Open 2 4 5 6 2 4 5 6 RPM 05 009 966 920 876 824 294 256 26 77 6 094 NOTES:. Factory sheave settings are shown in bold print. 2. Do not set motor sheave below minimum or maximum turns open shown.. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum External Static Pressure. 4. Drive data shown is for horizontal airflow with dry coil. Add component resistance (below) to duct resistance to determine total External Static Pressure. AIRFLOW CORRECTION FACTORS 2.5 TON [44.0 kw] (B5) ACTUALCFM [L/s] 800 [79] 4000 [888] 4200 [982] 4400 [2077] 4600 [27] 4800 [2265] TOTAL MBH 0.98 0.99.00.0.02.02 SENSIBLE MBH 0.9 0.96.00.04.07. POWER kw 0.99.00.00.00.0.0 5000 [260].0.4.02 NOTES:. Multiply correction factor times gross performance data. 2. Resulting sensible capacity cannot exceed total capacity. 5200 [2454].04.8.02 5400 [2549].05.2.0 5600 [264].06.25.0 5800 [277].07.28.0 COMPONENT AIR RESISTANCE, IWC 2.5 TON [44.0 kw] (B5) Wet Coil Component Downflow Economizer RA Damper Open Horizontal Economizer RA Damper Open Concentric Grill RXRN-AA6 or RXRN-AA7 & Transition RXMC-CE05 Concentric Grill RXRN-AA66 or RXRN-AA76 & Transition RXMC-CF06 800 [79] 0.08 [.02] 0.2 [.0] 0.07 [.02] 0.9 [.05] 0.2 [0.6] 4000 [888] 0.09 [.02] 0. [.0] 0.07 [.02] 0.2 [.05] 0.25 [0.6] 4200 [982] 0.09 [.02] 0.4 [.0] 0.08 [.02] 0.24 [.05] 0.27 [0.7] Standard Indoor AirflowCFM [L/s] 4400 [2076] 0.0 [.02] 0.5 [.04] 0.08 [.02] 0.27 [.07] 0.29 [0.7] 4600 [27] 0.0 [.02] 0.6 [.04] 0.09 [.02] 0.0 [.07] 0.0 [0.7] 4800 [2265] 5000 [259] ResistanceInches Water [kpa] NOTE: Add component resistance to duct resistance to determine total external static pressure. 0. [.0] 0.7 [.04] 0.0 [.02] 0. [.08] 0.2 [0.8] 0. [.0] 0.8 [.04] 0.0 [.02] 0.6 [.09] 0.4 [0.8] 5200 [2454] 0.2 [.0] 0.9 [.05] 0. [.0] 0.40 [.0] 0.6 [0.8] 5400 [2548] 0. [.0] 0.20 [.05] 0. [.0] 0.44 [.] 0.8 [0.9] 5600 [264] 0. [.0] 0.2 [.05] 0.2 [.0] 0.48 [.2] 0.40 [.0] 5800 [277] 0.4 [.0] 0.22 [.05] 0. [.0] 0.52 [.] 0.4 [.] 22

ELECTRICAL DATARLKL-B SERIES ELECTRICAL DATA RLKL SERIES Evaporator Fan Condenser Motor Compressor Motor Unit Information Unit Operating Voltage Range Volts Minimum Circuit Ampacity B090CL B090CM B090CN B090DL B090DM B090DN B090YL 87-25 208/20 40/40 87-25 208/20 40/40 87-25 208/20 45/45 44-506 Minimum Overcurrent Protection Device Size 50/50 50/50 60/60 25 25 0 20 Maximum Overcurrent Protection Device Size 60/60 60/60 60/60 0 0 0 20 No. Volts 200/240 200/240 200/240 480 480 480 600 Phase RPM 450 450 450 450 450 450 450 HP, Compressor 6 6 6 6 6 6 6 Amps (RLA), Comp. 2.2/2.2 2.2/2.2 2.2/2.2.2.2.2 7.9 Amps (LRA), Comp. 64/64 64/64 64/64 75 75 75 54 HP, Compressor 2 Amps (RLA), Comp. 2 Amps (LRA), Comp. 2 No. Volts 208/20 208/20 208/20 460 460 460 575 Phase HP /2 /2 /2 /2 /2 /2 /2 Amps (FLA, each) 2./2. 2./2. 2./2..5.5.5 Amps (LRA, each) 5.6/5.6 5.6/5.6 5.6/5.6... 2.2 No. Volts 208/20 208/20 208/20 460 460 460 575 Phase HP 2 2 2 2 2 Amps (FLA, each) 8/8 8/8 / 4 4 7 4 Amps (LRA, each) 56/56 56/56 74.5/74.5 28 28 8. 9 460 20 44-506 460 20 44-506 460 2 58-62 575 5 2

ELECTRICAL DATARLKL-B SERIES ELECTRICAL DATA RLKL SERIES Evaporator Fan Condenser Motor Compressor Motor Unit Information Unit Operating Voltage Range Volts Minimum Circuit Ampacity B090YM B090YN B20CL B20CM B20DL B20DM 58-62 575 5 58-62 575 9 87-25 208/20 5/5 87-25 208/20 56/56 44-506 Minimum Overcurrent Protection Device Size 20 25 60/60 70/70 5 5 Maximum Overcurrent Protection Device Size 20 25 80/80 80/80 40 45 No. Volts 600 600 200/240 200/240 480 480 Phase RPM 450 450 450 450 450 450 HP, Compressor 6 6 0 0 0 0 Amps (RLA), Comp. 7.9 7.9 0./0. 0./0. 6.7 6.7 Amps (LRA), Comp. 54 54 225/225 225/225 4 4 HP, Compressor 2 Amps (RLA), Comp 2 Amps (LLA), Comp 2 No. 2 2 2 2 Volts 575 575 208/20 208/20 460 460 Phase HP /2 /2 / / / / Amps (FLA, each) 2.4/2.4 2.4/2.4.4.4 Amps (LRA, each) 2.2 2.2 4.7/4.7 4.7/4.7 2.4 2.4 No. Volts 575 575 208/20 208/20 460 460 Phase HP 2 2 2 Amps (FLA, each) 4 8 8/8 / 4 7 Amps (LRA, each) 9 20 56/56 74.5/74.5 28 8. 460 28 44-506 460 B20YL 58-62 575 22 25 0 600 450 0 2.2 80 2 575 /.5 575 2 4 9 24

ELECTRICAL DATARLKL-B SERIES ELECTRICAL DATA RLKL SERIES Evaporator Fan Condenser Motor Compressor Motor Unit Information Unit Operating Voltage Range Volts Minimum Circuit Ampacity B20YM B5CL B5CM B5DL B5DM B5YL 58-62 575 26 87-25 208/20 67/67 87-25 208/20 7/7 44-506 Minimum Overcurrent Protection Device Size 0 70/70 75/75 5 40 0 Maximum Overcurrent Protection Device Size 5 80/80 90/90 40 45 5 No. 2 2 2 2 2 Volts 600 208/20 208/20 460 460 575 Phase RPM 450 450 450 450 450 450 HP, Compressor 0 5 /4 5 /4 5 /4 5 /4 5 /4 Amps (RLA), Comp. 2.2 22.4/22.4 22.4/22.4 0.6 0.6 7.7 Amps (LRA), Comp. 80 49/49 49/49 75 75 54 HP, Compressor 2 5 /4 5 /4 5 /4 5 /4 5 /4 Amps (RLA), Comp 2 9/9 9/9 9.7 9.7 7.4 Amps (LLA), Comp 2 2/2 2/2 62 62 50 No. 2 2 2 2 2 2 Volts 575 208/20 208/20 460 460 575 Phase HP / /2 /2 /2 /2 /2 Amps (FLA, each) 2./2. 2./2..5.5 Amps (LRA, each).5 5.6/5.6 5.6/5.6.. 2.2 No. Volts 575 208/20 208/20 460 460 575 Phase HP 5 5 Amps (FLA, each) 8 5/5 8.8/8.8 7 0 8 Amps (LRA, each) 20 74.5/74.5 82.6/82.6 8. 4. 20 460 44-506 460 6 58-62 575 28 B5YM 58-62 575 28 0 5 2 575 450 5 /4 7.7 54 5 /4 7.4 50 2 575 /2 2.2 575 5 8 25

UNITS WITH HEATER KITSRLKL-B SERIES Unit Model No. RLKL- B090CL B20CL B5CL B090CM B20CM RXJJ- Heater Kit Nominal kw 208/240 VOLT, THREE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION No. of Sequence Steps Single Power Supply For Both Unit and Heater Kit Separate Power Supply For Both Unit and Heater Kit Heater Kit Air Conditioner Heater Kit Air Conditioner Rated Heater kw @ 208/240 V Heater KBTU/Hr @ 208/240 V Heater Amp. @ 208/240 V Unit Min. Ckt. Ampacity @ 208/240 V Over Current Protective Device Size Min./Max. @ 208 V Min./Max. @ 240 V No Heat 40/40 50/60 50/60 CC0C 7.2/9.6 24.56/2.75 20/2. 40/40 50/60 50/60 CC5C 0.8/4.4 6.84/49. 0/4.6 48/54 50/60 60/60 Min. Ckt. Ampacity 208/240 V Max. Fuse Size 208/240 V Min. Circuit Ampacity 208/240 V Over Current Protective Device Size Min./Max. @ 208 V Min./Max. @ 240 V 40/40 50/60 50/60 25/29 25/0 8/44 40/45 CC20C 4.4/9.2 49./65.5 40/46.2 60/68 60/60 70/70 50/58 50/60 CC0C 2.6/28.8 7.69/98.25 60/69. 85/97 90/90 00/00 75/87 80/90 CCC 2.6/28.8 7.69/98.25 60/69. 85/97 90/90 00/00 75/87 80/90 CC40C 28.8/8.4 98.25/ 80./92.4 /26 25/25 50/50 0/6 0/25 CC4C 28.8/8.4 98.25/ 80./92.4 /26 25/25 50/50 0/6 0/25 No Heat 5/5 60/80 60/80 5/5 60/80 60/80 CC0C 7.2/9.6 24.56/2.75 20/2. 5/5 60/80 60/80 25/29 25/0 CC5C 0.8/4.4 6.84/49. 0/4.6 5/54 60/80 60/80 8/44 40/45 CC20C 4.4/9.2 49./65.5 40/46.2 60/68 60/80 70/80 50/58 50/60 CC0C 2.6/28.8 7.69/98.25 60/69. 85/97 90/90 00/00 75/87 80/90 CC40C 28.8/8.4 98.25/ 80./92.4 /26 25/25 50/50 0/6 0/25 CC50C 6./48 2.6/6.75 00./5.5 6/55 50/50 75/75 26/45 50/50 No Heat 67/67 70/80 70/80 67/67 70/80 70/80 CC0C 7.2/9.6 24.56/2.75 20/2. 67/67 80/80 80/80 25/29 25/0 CC5C 0.8/4.4 6.84/49. 0/4.6 67/67 80/80 80/80 8/44 40/45 CC20C 4.4/9.2 49./65.5 40/46.2 69/77 80/80 80/80 50/58 50/60 CC0C 2.6/28.8 7.69/98.25 60/69. 94/06 00/00 0/0 75/87 80/90 CC40C 28.8/8.4 98.25/ 80./92.4 9/5 25/25 50/50 0/6 0/25 CC50C 6./48 2.6/6.75 00./5.5 44/64 50/50 75/75 26/45 50/50 No Heat 40/40 50/60 50/60 40/40 50/60 50/60 CC0C 7.2/9.6 24.56/2.75 20/2. 40/40 50/60 50/60 25/29 25/0 CC5C 0.8/4.4 6.84/49. 0/4.6 48/54 50/60 60/60 8/44 40/45 CC20C 4.4/9.2 49./65.5 40/46.2 60/68 60/60 70/70 50/58 50/60 CC0C 2.6/28.8 7.69/98.25 60/69. 85/97 90/90 00/00 75/87 80/90 CCC 2.6/28.8 7.69/98.25 60/69. 85/97 90/90 00/00 75/87 80/90 CC40C 28.8/8.4 98.25/ 80./92.4 /26 25/25 50/50 0/6 0/25 CC4C 28.8/8.4 98.25/ 80./92.4 /26 25/25 50/50 0/6 0/25 No Heat 56/56 70/80 70/80 56/56 70/80 70/80 CC0C 7.2/9.6 24.56/2.75 20/2. 56/56 70/80 70/80 25/29 25/0 CC5C 0.8/4.4 6.84/49. 0/4.6 56/60 70/80 70/80 8/44 40/45 CC20C 4.4/9.2 49./65.5 40/46.2 67/75 70/80 80/80 50/58 50/60 CC0C 2.6/28.8 7.69/98.25 60/69. 92/0 00/00 0/0 75/87 80/90 CC40C 28.8/8.4 98.25/ 80./92.4 7/2 25/25 50/50 0/6 0/25 CC50C 6./48 2.6/6.75 00./5.5 42/6 50/50 75/75 26/45 50/50 *= For Canadian use only. Uses P fuses for inductive circuit. + = Field installed only. 26

UNITS WITH HEATER KITSRLKL-B SERIES Unit Model No. RLKL- C5CM B090CN RXJJ- Heater Kit Nominal kw 208/240 VOLT, THREE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION No. of Sequence Steps Single Power Supply For Both Unit and Heater Kit Separate Power Supply For Both Unit and Heater Kit Heater Kit Air Conditioner Heater Kit Air Conditioner Rated Heater kw @ 208/240 V Heater KBTU/Hr @ 208/240 V Heater Amp. @ 208/240 V Unit Min. Ckt. Ampacity @ 208/240 V Over Current Protective Device Size Min./Max. @ 208 V Min./Max. @ 240 V No Heat 7/7 75/90 75/90 CC0C 7.2/9.6 24.56/2.75 20/2. 7/7 80/90 80/90 CC5C 0.8/4.4 6.84/49. 0/4.6 7/7 80/90 80/90 Min. Ckt. Ampacity 208/240 V Max. Fuse Size 208/240 V Min. Circuit Ampacity 208/240 V Over Current Protective Device Size Min./Max. @ 208 V Min./Max. @ 240 V 7/7 75/90 75/90 25/29 25/0 8/44 40/45 CC20C 4.4/9.2 49./65.5 40/46.2 74/82 80/90 90/90 50/58 50/60 CC0C 2.6/28.8 7.69/98.25 60/69. 99/ 00/00 25/25 75/87 80/90 CC40C 28.8/8.4 98.25/ 80./92.4 24/40 25/25 50/50 0/6 0/25 ----- ----- ----- CC50C 6./48 2.6/6.75 00./5.5 49/68 50/50 75/75 26/45 50/50 ----- ----- ----- No Heat 45/45 60/60 60/60 45/45 60/60 60/60 CC0C 7.2/9.6 24.56/2.75 20/2. 45/46 60/60 60/60 25/29 25/0 CC5C 0.8/4.4 6.84/49. 0/4.6 54/60 60/60 60/60 8/44 40/45 CC20C 4.4/9.2 49./65.5 40/46.2 67/75 70/70 80/80 50/58 50/60 CC0C 2.6/28.8 7.69/98.25 60/69. 92/0 00/00 0/0 75/87 80/90 CCC 2.6/28.8 7.69/98.25 60/69. 92/0 00/00 0/0 75/87 80/90 CC40C 28.8/8.4 98.25/ 80./92.4 7/2 25/25 50/50 0/6 0/25 CC4C 28.8/8.4 98.25/ 80./92.4 7/2 25/25 50/50 0/6 0/25 *= For Canadian use only. Uses P fuses for inductive circuit. + = Field installed only. 27

UNITS WITH HEATER KITSRLKL-B SERIES Unit Model No. RLKL- B090DL B20DL B5DL B090DM B20DM RXJJ- Heater Kit Nominal kw 480 VOLT, THREE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION No. of Sequence Steps Single Power Supply For Both Unit and Heater Kit Separate Power Supply For Both Unit and Heater Kit Heater Kit Air Conditioner Heater Kit Air Conditioner Rated Heater kw @ 480 V Heater KBTU/Hr @ 480 V Heater Amp. @ 480 V Unit Min. Ckt. Ampacity @ 480 V Over Current Protective Device Size Min./Max. @ 480 V Min./Max. @ 480 V No Heat 20 25/0 CC0D 9.6 2.75.5 20 25/0 CC5D 4.4 49. 7. 27 0/0 Min. Ckt. Ampacity 480 V Max. Fuse Size 480 V Min. Circuit Ampacity 480 V Over Current Protective Device Size Min./Max. @ 480 V Min./Max. @ 480 V 20 25/0 5 5 22 25 CC20D 9.2 65.5 2. 4 5/5 29 0 CC0D 28.8 98.25 4.6 49 50/50 44 45 CCD 28.8 98.25 4.6 49 50/50 44 45 CC40D 8.4 46.2 6 70/70 58 60 CC4D 8.4 46.2 6 70/70 58 60 No Heat 28 5/40 28 5/40 CC0D 9.6 2.75.5 28 5/40 5 5 CC5D 4.4 49. 7. 28 5/40 22 25 CC20D 9.2 65.5 2. 4 5/40 29 0 CC0D 28.8 98.25 4.6 49 50/50 44 45 CC40D 8.4 46.2 6 70/70 58 60 CC50D 48 6.75 57.7 78 80/80 7 80 No Heat 5/40 5/40 CC0D 9.6 2.75.5 40/40 5 5 CC5D 4.4 49. 7. 40/40 22 25 CC20D 9.2 65.5 2. 8 40/40 29 0 CC0D 28.8 98.25 4.6 52 60/60 44 45 CC40D 8.4 46.2 67 70/70 58 60 CC50D 48 6.75 57.7 8 90/90 7 80 No Heat 20 25/0 20 25/0 CC0D 9.6 2.75.5 20 25/0 5 5 CC5D 4.4 49. 7. 27 0/0 22 25 CC20D 9.2 65.5 2. 4 5/5 29 0 CC0D 28.8 98.25 4.6 49 50/50 44 45 CCD 28.8 98.25 4.6 49 50/50 44 45 CC40D 8.4 46.2 6 70/70 58 60 CC4D 8.4 46.2 6 70/70 58 60 No Heat 5/45 5/45 CC0D 9.6 2.75.5 5/45 5 5 CC5D 4.4 49. 7. 5/45 22 25 CC20D 9.2 65.5 2. 8 40/45 29 0 CC0D 28.8 98.25 4.6 52 60/60 44 45 CC40D 8.4 46.2 67 70/70 58 60 CC50D 48 6.75 57.7 8 90/90 7 80 *= For Canadian use only. Uses P fuses for inductive circuit. + = Field installed only. 28

UNITS WITH HEATER KITSRLKL-B SERIES Unit Model No. RLKL- B5DM B090DN RXJJ- Heater Kit Nominal kw 480 VOLT, THREE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION No. of Sequence Steps Single Power Supply For Both Unit and Heater Kit Separate Power Supply For Both Unit and Heater Kit Heater Kit Air Conditioner Heater Kit Air Conditioner Rated Heater kw @ 480 V Heater KBTU/Hr @ 480 V Heater Amp. @ 480 V Unit Min. Ckt. Ampacity @ 480 V Over Current Protective Device Size Min./Max. @ 480 V Min./Max. @ 480 V No Heat 6 40/45 CC0D 9.6 2.75.5 6 40/45 CC5D 4.4 49. 7. 6 40/45 Min. Ckt. Ampacity 480 V Max. Fuse Size 480 V Min. Circuit Ampacity 480 V Over Current Protective Device Size Min./Max. @ 480 V Min./Max. @ 480 V 6 40/45 5 5 22 25 CC20D 9.2 65.5 2. 42 45/45 29 0 CC0D 28.8 98.25 4.6 56 60/60 44 45 CC40D 8.4 46.2 7 80/80 58 60 CC50D 48 6.75 57.7 85 90/90 7 80 No Heat 2 0/0 2 0/0 CC0D 9.6 2.75.5 24 0/0 5 5 CC5D 4.4 49. 7. 5/5 22 25 CC20D 9.2 65.5 2. 8 40/40 29 0 CC0D 28.8 98.25 4.6 52 60/60 44 45 CCD 28.8 98.25 4.6 52 60/60 44 45 CC40D 8.4 46.2 67 70/70 58 60 CC4D 8.4 46.2 67 70/70 58 60 *= For Canadian use only. Uses P fuses for inductive circuit. + = Field installed only. 29

UNITS WITH HEATER KITSRLKL-B SERIES Unit Model No. RLKL- B090YL B20YL B5YL B090YM B20YM RXJJ- Heater Kit Nominal kw 600 VOLT, THREE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION No. of Sequence Steps Single Power Supply For Both Unit and Heater Kit Separate Power Supply For Both Unit and Heater Kit Heater Kit Air Conditioner Heater Kit Air Conditioner Rated Heater kw @ 600 V Heater KBTU/Hr @ 600 V Heater Amp. @ 600 V Unit Min. Ckt. Ampacity @ 600 V Over Current Protective Device Size Min./Max. @ 600 V Min./Max. @ 600 V No Heat 5 20/20 CC0Y 9.6 2.75 9.2 7 20/20 CC5Y 4.4 49..9 2 25/25 Min. Ckt. Ampacity 600 V Max. Fuse Size 600 V Min. Circuit Ampacity 600 V Over Current Protective Device Size Min./Max. @ 600 V Min./Max. @ 600 V 5 20/20 2 5 8 20 CC20Y 9.2 65.5 8.5 29 0/0 24 25 CC0Y 28.8 98.25 27.7 40 40/40 5 5 CC40Y 8.4 7 52 60/60 47 50 No Heat 22 25/0 22 25/0 CC0Y 9.6 2.75 9.2 22 25/0 2 5 CC5Y 4.4 49..9 2 25/0 8 20 CC20Y 9.2 65.5 8.5 29 0/0 24 25 CC0Y 28.8 98.25 27.7 40 40/40 5 5 CC40Y 8.4 7 52 60/60 47 50 CC50Y 48 6.75 46.2 6 70/70 58 60 No Heat 28 0/5 28 0/5 CC0Y 9.6 2.75 9.2 28 0/5 2 5 CC5Y 4.4 49..9 28 0/5 8 20 CC20Y 9.2 65.5 8.5 4 5/5 24 25 CC0Y 28.8 98.25 27.7 45 45/45 5 5 CC40Y 8.4 7 57 60/60 47 50 CC50Y 48 6.75 46.2 68 70/70 58 60 No Heat 5 20/20 5 20/20 CC0Y 9.6 2.75 9.2 7 20/20 2 5 CC5Y 4.4 49..9 2 25/25 8 20 CC20Y 9.2 65.5 8.5 29 0/0 24 25 CC0Y 28.8 98.25 27.7 40 40/40 5 5 CC40Y 8.4 7 52 60/60 47 50 No Heat 26 0/5 26 0/5 CC0Y 9.6 2.75 9.2 26 0/5 2 5 CC5Y 4.4 49..9 28 0/5 8 20 CC20Y 9.2 65.5 8.5 4 5/5 24 25 CC0Y 28.8 98.25 27.7 45 45/45 5 5 CC40Y 8.4 7 57 60/60 47 50 CC50Y 48 6.75 46.2 68 70/70 58 60 *= For Canadian use only. Uses P fuses for inductive circuit. + = Field installed only. 0

UNITS WITH HEATER KITSRLKL-B SERIES Unit Model No. RLKL- B5YM B090YN RXJJ- Heater Kit Nominal kw 600 VOLT, THREE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION No. of Sequence Steps Single Power Supply For Both Unit and Heater Kit Separate Power Supply For Both Unit and Heater Kit Heater Kit Air Conditioner Heater Kit Air Conditioner Rated Heater kw @ 600 V Heater KBTU/Hr @ 600 V Heater Amp. @ 600 V Unit Min. Ckt. Ampacity @ 600 V Over Current Protective Device Size Min./Max. @ 600 V Min./Max. @ 600 V No Heat 28 0/5 CC0Y 9.6 2.75 9.2 28 0/5 CC5Y 4.4 49..9 28 0/5 Min. Ckt. Ampacity 600 V Max. Fuse Size 600 V Min. Circuit Ampacity 600 V Over Current Protective Device Size Min./Max. @ 600 V Min./Max. @ 600 V 28 0/5 2 5 8 20 CC20Y 9.2 65.5 8.5 4 5/5 24 25 CC0Y 28.8 98.25 27.7 45 45/45 5 5 CC40Y 8.4 7 57 60/60 47 50 CC50Y 48 6.75 46.2 68 70/70 58 60 No Heat 9 25/25 9 25/25 CC0Y 9.6 2.75 9.2 22 25/25 2 5 CC5Y 4.4 49..9 28 0/0 8 20 CC20Y 9.2 65.5 8.5 4 5/5 24 25 CC0Y 28.8 98.25 27.7 45 45/45 5 5 CC40Y 8.4 7 57 60/60 47 50 *= For Canadian use only. Uses P fuses for inductive circuit. + = Field installed only.

UNIT DIMENSIONSRLKL-B SERIES PACKAGE AIR CONDITIONER ST-A075-0-X BOTTOM VIEW ST-A54-0 2

UNIT DIMENSIONSRLKL-B SERIES PACKAGE AIR CONDITIONER SUPPLY AND RETURN DIMENSIONS FOR HORIZONTAL APPLICATIONS ST-A076-02-X *RECOMMENDED DUCT DIMENSIONS ARE 26" SUPPLY AND RETURN DIMENSIONS FOR DOWNFLOW APPLICATIONS ST-A078-02

UNIT DIMENSIONSRLKL-B SERIES PACKAGE AIR CONDITIONER ST-A54-04 4

UNIT DIMENSIONSRLKL-B SERIES WEIGHTS Accessory Shippinglbs [kg] Operatinglbs [kg] Economizer 90 [40.82] 8 [6.70] Power Exhaust 44 [9.96] 42 [9.05] Fresh Air Damper (Manual) 26 [.79] 2 [9.5] Fresh Air Damper (Motorized) 4 [9.50] 8 [7.24] Roof Curb 4" 90 [40.82] 85 [8.60] Roof Curb 24" 40 [6.50] 5 [6.2] Capacity Tons [kw] 7.5 [26.4] 0 [5.2] 2.5 [44.0] Corner Weights by Percentage A B C D 0% 5% 4% 2% % 27% 7% 2% 44% 0% 2% 4% A07440 CLEARANCES The following minimum clearances must be observed for proper unit performance and serviceability. Recommended Clearance In. [mm] Location 48 [29] A - Front 8 [457] B - Condenser Coil 8 [457] C - Duct Side 8 [457] *D - Evaporator End 60 [524] E - Above *Without Economizer. 48" [29 mm] With Economizer 5

ACCESSORIES FIELD INSTALLED ACCESSORY EQUIPMENT Accessory Model Number Shipping Weight Lbs. [kg] Installed Weight Lbs. [kg] Factory Installation Available? Thermostats See Thermostat Specification Sheet for Details (T-00) No RXJJ-CC0 (C,D,Y) 46 [20.9]0 6 [6.] Yes Electric Heaters* Canadian Use Only. RXJJ-CC5 (C,D,Y) 46 [20.9]0 6 [6.] Yes RXJJ-CC20 (C,D,Y) 46 [20.9]0 6 [6.] Yes Electric Heaters* Canadian Use Only. RXJJ-CC0 (C,D,Y) 47 [2.]0 7 [6.8] Yes Electric Heaters* Canadian Use Only. RXJJ-CC40 (C,D,Y) 49 [22.2]0 9 [7.7] Yes Electric Heaters* Canadian Use Only. RXJJ-CC50 (C,D,Y) 5 [2.]0 4 [8.6] Yes Economizer w/single Enthalpy RXRD-PDCM 90 [40.8]0 8 [6.7] Yes Economizer w/single Enthalpy and Smoke Dectector RXRD-SDCM 9 [4.]0 82 [7.2] Yes Dual Enthalpy Kit RXRX-AV02 [0.5]0 [0.5] No Horizontal Economizer w/single Enthalpy RXRD-RDCM 94 [42.6]0 89 [40.4] No Carbon Dioxide Sensor RXRX-AR02 [.4]0 2 [.0] No Power Exhaust RXRX-BFF02 (C,D,Y) 4 [9.5]0 8 [7.2] No Manual Fresh Air (Left Panel Mounted) RXRF-KDA 8 [7.2]0 [4.0] No Manual Fresh Air (Return Panel) RXRF-JDA 26 [.8]0 2 [9.5] No Motorized Fresh Air (Return Panel) RXRF-JDB 4 [9.5]0 2 [9.5] No Motor Kit for RXRF-KDA (Left Panel Mounted) RXRX-AW02 5 [5.9]0 27 [7.7] No Roofcurb, 4" RXKG-CAE4 90 [40.8]0 85 [8.5] No Roofcurb, 24" RXKG-CAE24 40 [6.5]0 5 [6.2] No Roofcurb Adapters RXRX-CDCE50 00 [6.]0 290 [.5] No RXRX-CFCE54 25 [47.4]0 5 [42.9] No RXRX-CFCE56 50 [58.8]0 40 [54.2] No RXRX-CGCC2 450 [204.]0 40 [86.0] No Concentric Diffuser (Step-Down, 8 x 28) RXRN-AA6 200 [90.7]0 85 [8.9] No Concentric Diffuser (Step-Down, 8 x 2) RXRN-AA66 247 [2.0]0 227 [0.0] No Concentric Diffuser (Flush, 8 x 28) RXRN-AA7 70 [77.]0 55 [70.] No Concentric Diffuser (Flush, 8 x 2) RXRN-AA76 76 [79.8]0 6 [7.0] No Downflow Adapters (Rect. to Round) RXMC-CD04 5 [6.8]0 [5.9] No Downflow Adapters (Rect. to Rect., 8 x 28) RXMC-CE05 ➀ 8 [8.2]0 6 [7.] No Downflow Adapters (Rect. to Rect., 8 x 2) RXMC-CF06 ➁ 20 [9.]0 8 [8.2] No Compressor Time-Delay Relay Kit RXMD-A04 2 [.0]0 [0.5] No Low-Ambient Control Kit ( Per Compressor) RXRZ-C02 [.4]0 2 [.0] Yes Freeze-Stat Kit RXRX-AM0 [0.5]0 0.5 [0.2] Yes Outdoor Coil Louver Kit RXRX-AAD02A (7 /2-2 /2 Ton) 29 [.]0 26 [.8] Yes Unwired Convenience Outlet RXRX-AN0 2 [.0]0.5 [0.7] Yes NOTES: ➀ Used with RXRN-AA6 and RXRN-AA7 concentric diffusers. ➁ Used with RXRN-AA66 and RXRN-AA76 concentric diffusers. ➂ Please refer to conversion kit index provided with the unit for LP conversion kit. 6

7 ACCESSORIES

ACCESSORIES ECONOMIZER FOR DOWNFLOW DUCT INSTALLATION Use to Select Factory Installed Options Only RXRD-PDCMSingle Enthalpy (Outdoor) and RXRD-SDCM Single Enthalpy with Smoke Detector RXRX-AV02Dual Enthalpy Upgrade Kit RXRX-AR02Optional Wall-Mounted CO 2 Sensor Features Honeywell Controls Available Factory Installed or Field Accessory Gear Driven Direct Drive Actuator Fully Modulating (0-00%) Low Leakage Dampers Slip-In Design for Easy Installation Plug-In Polarized 2-pin Electrical Connections Pre-ConfiguredNo Field Adjustments Necessary Standard Barometric Relief Damper Single Enthalpy with Dual Enthalpy Upgrade Kit Available CO2 Input Sensor Available Field Assembled Hood Ships with Economizer Economizer Ships Complete for Downflow Duct Application. Optional Remote Minimum Position Potentiometer (Honeywell #S96B28) is Available from Prostock. Field Installed Power Exhaust Available Prewired for Smoke Detector ADS-7949-8

ACCESSORIES ECONOMIZER FOR HORIZONTAL DUCT INSTALLATION Field Installed Only RXRD-RDCMSingle Enthalpy (Outdoor) RXRX-AV02Dual Enthalpy Upgrade Kit RXRX-AR02Wall-mounted CO 2 Sensor Features Honeywell Controls Available as a Field Installed Accessory Only Gear Driven Direct Drive Actuator Fully Modulating (0-00%) Low Leakage Dampers Slip-In Design for Easy Installation Plug-In Polarized 2-pin Electrical Connections Pre-Configured No Field Adjustments Necessary Standard Barometric Relief Damper Single Enthalpy with Dual Enthalpy Upgrade Kit Available CO2 Input Sensor Available Field Assembled Hood Ships with Economizer Economizer Ships Complete for Horizontal Duct Application Optional Remote Minimum Position Potentiometer (Honeywell #S96B28) is Available from Prostock Field Installed Power Exhaust Available 9

ACCESSORIES POWER EXHAUST KIT FOR RXRD-PDCM(-), RXRD-RDCM(-), RXRD-SDCM ECONOMIZERS RXRX-BFF02 (C, D, or Y*) *Voltage Code VERTICAL AIRFLOW STA000-02 HORIZONTAL AIRFLOW STA000-0 Model No. No. HP Low Speed High Speed ➀ FLA LRA Volts Phase of Fans (ea.) CFM [L/s] ➁ RPM CFM [L/s] ➁ RPM (ea.) (ea.) RXRX-BFF02C 2 208-20 0. 2200 [08] 58 2500 [79] 670.48.6 RXRX-BFF02D 2 460 0. 2200 [08] 58 2500 [79] 670 0.75.8 RXRX-BFF02Y 2 575 0. 2200 [08] 58 2500 [79] 670 0.8.5 NOTES: ➀ Power exhaust is factory set on high speed motor tap. ➁ CFM is per fan at 0" w.c. external static pressure. 40

ACCESSORIES FRESH AIR DAMPER MOTORIZED DAMPER KIT RXRX-AWO2 (Motor Kit for RXRF-KDA) 795-7a RXRF-KDA (Manual) DOWNFLOW OR HORIZONTAL APPLICATION ST-795-7 ST-A0886-8 4

ACCESSORIES FRESH AIR DAMPER (Cont.) RXRF-JDA (Manual) RXRF-JDB (Motorized) DOWNFLOW APPLICATION ADS-797-58 HORIZONTAL APPLICATION ST-A090-0 42

ROOFCURBS (Full Perimeter) Rheem s roofcurb design can be utilized on 7.5 & 0 ton [26.4 & 5.2 kw] RLKL-B models. Two available heights (4" [56 mm] and 24" [60 mm]) for ALL models. Quick assembly corners for simple and fast assembly. Opening provided in bottom pan to match the Thru the Curb electrical connection opening provided on the unit base pan. " [25 mm] x 4" [02 mm] Nailer provided. Insulating panels not required because of insulated outdoor base pan. Sealing gasket (40' [2.2 m]) provided with Roofcurb. Packaged for easy field assembly. ST-A074-02 TYPICAL INSTALLATION ACCESSORIES Roofcurb Model RXKG-CAE4 RXKG-CAE24 Height of Curb 4" [56 mm] 24" [60 mm] ROOFCURB INSTALLATION ST-A074-02 ST-A080-7 4

ACCESSORIES ROOFCURB ADAPTERS OLD MODELS OLD ROOFCURB ROOFCURB ADAPTER (-)RCF, (-)REF-075/076 (-)RGF-50075, (-)RGF-076 (-)RGF-20076 RXRK-E50 RXRX-CDCE50 NEW MODELS (All Share Common Cabinet) (-)RGF-200075 (-)RGG, (-)REG, (-)RCG-075 (-)RGF, (-)REF, (-)RCF-085 (-)RGF, (-)REF, (-)RCF-00 (-)RGG, (-)REG, (-)RCG-00 RXRK-E54 RXRX-CFCE54 (R)LKL-B090 (R)LKL-B20 (R)LKL-B5 (-)RGF, (-)REF, (-)RCF-25 RXRK-E56 RXRX-CFCE56 (-)PDC-075 (-)PDC-00/0 RXPK-C2 RXRX-CGCC2 NOTE: Ductwork modifications may be necessary if the capacity and/or indoor airflow rate of replacement unit is not equivalent to that of the unit being replaced. RLKL- B090, B20 and B5 on same roofcurb as the RLKB- A090, A20 and A50, RLMB- A090, A20 and A50, RLNB- A090 and A20. 44

ACCESSORIES ROOFCURB ADAPTERS (Cont.) RXRX-CDCE50 ADS-7952-02 Sheet 2 TOP VIEW ADS-7952-02 Sheet 45

ACCESSORIES ROOFCURB ADAPTERS (Cont.) RXRX-CFCE54 ADS-7952-0 Sheet 2 TOP VIEW ADS-7952-0 Sheet 46

ACCESSORIES ROOFCURB ADAPTERS (Cont.) RXRX-CFCE56 ADS-7952-0 Sheet 2 TOP VIEW ADS-7952-0 Sheet 47

ACCESSORIES ROOFCURB ADAPTERS (Cont.) RXRX-CGCC2 ADS-7952-04 Sheet 2 TOP VIEW ADS-7952-04 Sheet 48

ACCESSORIES CONCENTRIC DIFFUSER APPLICATION ST-A0840-02 DOWNFLOW TRANSITION DRAWINGS RXMC-CE05 Used with RXRN-AA6 or RXRN-AA7 Concentric Diffusers. ST-A088-02 49

ACCESSORIES DOWNFLOW TRANSITION DRAWINGS (Cont.) RXMC-CF06 Used with RXRN-AA66 or RXRN-AA76 Concentric Diffusers. ST-A088-0 50

ACCESSORIES DOWNFLOW TRANSITION DRAWINGS (Cont.) RXMC-CD04 Used with RXRN-FA65 or RXRN-FA75 Concentric Diffusers. 7950 ADS-795-0 5

ACCESSORIES CONCENTRIC DIFFUSERSTEP DOWN RXRN-FA65 (7.5 & 8.5 Ton [26.4 & 29.9 kw] Models) For Use With Downflow Transition (RXMC-CD04) and 20" [508 mm] Round Supply and Return Ducts All aluminum diffuser with aluminum return air eggcrate. Built-in anti-sweat gasket. Molded fiberglass supports. Built-in hanging supports. Diffuser box constructed of sheetmetal insulated with " [25.4 mm].5 lbs. [.7 kg] duct liner. ENGINEERING DATA ➀ Model No. RXRN-FA65 Flow Rate Static Pressure Throw ➁➂ Neck Velocity Noise Level ➃ CFM [L/s] in. w.c. [kpa] Feet [m] fpm [m/s] (dba) 2600 [227] 0.7 [0.042] 24-29 [7.-8.8]0 669 [.4] 20 2800 [2] 0.20 [0.050] 25-0 [7.6-9.]0 720 [.7] 25 000 [46] 0.25 [0.062] 27- [8.2-0.] 772 [.9] 25 200 [50] 0. [0.077] 28-5 [8.5-0.7] 82 [4.2] 25 400 [604] 0.7 [0.092] 0-7 [9.-.] 874 [4.4] 0 NOTES: ➀ All data is based on the air diffusion council guidelines. ➁ Throw data is based on 75 FPM Terminal Velocities using isothermal air. ➂ Throw is based on diffuser blades being directed in a straight pattern. ➃ Actual noise levels may vary due to duct design and do not include transmitted unit noise. Adequate duct attenuation must be provided to reduce sound output from the unit. 52

ACCESSORIES CONCENTRIC DIFFUSERSTEP DOWN 8" x 28" [457.2 x 7.2 mm] RXRN-AA6 (8.5 & 0 Ton [29.9 kw & 5.2] Models) For Use With Downflow Transition (RXMC-CE05) and 8" x 28" [457.2 x 7.2 mm] Supply and Return Ducts All aluminum diffuser with aluminum return air eggcrate. Built-in anti-sweat gasket. Molded fiberglass supports. Built-in hanging supports. Diffuser box constructed of sheetmetal insulated with " [25.4 mm].5 lbs. [.7 kg] duct liner. Double deflection diffuser with the blades secured by spring steel. ADS-795-08A ADS-795-08B ADS-795-08C ENGINEERING DATA ➀ Model No. RXRN-AA6 Flow Rate CFM [L/s] Static Pressure in w.c. [kpa] Throw ➁➂ Feet [m] Neck Velocity fpm [m/s] Noise Level ➃ (dba) 600 [699] 0.7 [0.042] 25- [7.6-0.] 85 [4.] 0 800 [79] 0.8 [0.045] 27-5 [8.2-0.7] 898 [4.6] 0 4000 [888] 0.2 [0.052] 29-7 [8.8-.] 946 [4.8] 0 4200 [982] 0.24 [0.060] 2-40 [9.8-2.2] 99 [5.0] 0 4400 [2076] 0.27 [0.067] 4-42 [0.4-2.8] 040 [5.] 0 NOTES: ➀ All data is based on the air diffusion council guidelines. ➁ Throw data is based on 75 FPM Terminal Velocities using isothermal air. ➂ Throw is based on diffuser blades being directed in a straight pattern. ➃ Actual noise levels may vary due to duct design and do not include transmitted unit noise. Adequate duct attenuation must be provided to reduce sound output from the unit. 5

ACCESSORIES FLUSH MOUNT CONCENTRIC DIFFUSERFLUSH RXRN-FA75 (7.5 & 8.5 Ton [26.4 & 29.9 kw] Models) For Use With Downflow Transition (RXMC-CD04) and 20" [508 mm] Round Supply and Return Ducts All aluminum diffuser with aluminum return air eggcrate. Built-in anti-sweat gasket. Molded fiberglass supports. Built-in hanging supports. Diffuser box constructed of sheetmetal insulated with " [25.4 mm].5 lbs. [.7 kg] duct liner. ADS-548-04 ENGINEERING DATA ➀ Model No. Flow Rate Static Pressure Throw ➁➂ Neck Velocity Noise Level ➃ CFM [L/s] in. w.c. [kpa] Feet [m] fpm [m/s] (dba) 2600 [227].7 [0.042] 9-24 [5.8-7.] 66 [.4] 0 2800 [2].20 [0.050] 20-28 [6.-8.5] 74 [.6] 5 RXRN-FA75 000 [46].25 [0.062] 2-29 [6.4-8.8] 765 [.9] 5 200 [50]. [0.077] 22-29 [6.7-8.8] 86 [4.] 40 400 [604].7 [0.092] 22-0 [6.7-9.] 867 [4.4] 40 NOTES: ➀ All data is based on the air diffusion council guidelines. ➁ Throw data is based on 75 FPM Terminal Velocities using isothermal air. ➂ Throw is based on diffuser blades being directed in a straight pattern. ➃ Actual noise levels may vary due to duct design and do not include transmitted unit noise. Adequate duct attenuation must be provided to reduce sound output from the unit. 54

ACCESSORIES CONCENTRIC DIFFUSERFLUSH and 8" x 28" [457.2 x 7.2 mm] RXRN-AA7 (8.5 & 0 Ton [29.9 & 5.2] Models) For Use With Downflow Transition (RXMC-CE05) and 8" x 28" [457.2 x 7.2 mm] Supply and Return Ducts All aluminum diffuser with aluminum return air eggcrate. Built-in anti-sweat gasket. Molded fiberglass supports. Built-in hanging supports. Diffuser box constructed of sheetmetal insulated with " [25.4 mm].5 lbs. [.7 kg] duct liner. ADS-795-06A ADS-795-06B ADS-795-06C ENGINEERING DATA ➀ Model No. RXRN-AA7 Flow Rate CFM [L/s] Static Pressure in w.c. [kpa] Throw ➁➂ Feet [m] Neck Velocity fpm [m/s] Noise Level ➃ (dba) 600 [699] 0.7 [0.042] 22-29 [6.7-8.8] 844 [4.] 5 800 [79] 0.8 [0.045] 22-0 [6.7-9.] 89 [4.5] 40 4000 [888] 0.2 [0.052] 24- [7.-0.] 98 [4.8] 40 4200 [982] 0.24 [0.060] 26-5 [7.9-0.7] 985 [5.0] 40 4400 [2076] 0.27 [0.067] 28-7 [8.5-.] 02 [5.2] 40 NOTES: ➀ All data is based on the air diffusion council guidelines. ➁ Throw data is based on 75 FPM Terminal Velocities using isothermal air. ➂ Throw is based on diffuser blades being directed in a straight pattern. ➃ Actual noise levels may vary due to duct design and do not include transmitted unit noise. Adequate duct attenuation must be provided to reduce sound output from the unit. 55

MECHANICAL SPECIFICATIONSRLKL-B SERIES General Units shall be convertible airflow. Operating range for units with electromechanical controls shall be between 25 F (5.7 C) and 50 F (4.4 C). Cooling performance shall be rated in accordance with DOE and/or AHRI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-40A, and 00 percent run-tested before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 995/CAN/CSA No. 26-M90 for central cooling air conditioners. Canadian units shall be CUL certified. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weatherresistant baked enamel finish. Unit s surface shall be tested 000 hours in a salt spray test in compliance with ASTM B7. Cabinet construction shall allow for all maintenance on one side of the unit. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil faced, fire retardant permanent, odorless glass fiber material and secured with adhesive and mechanical fasteners. The base of the unit shall be insulated with foil-faced material. All insulation edges shall be either captured or sealed. The unit s base pan shall have no penetrations within the perimeter of the curb other than the raised -/8 [28.58 mm] high downflow supply return openings to provide an added water integrity precaution. The base rails of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The indoor top cover shall be one-piece construction, it shall not be doublehemmed and gasket-sealed. Filters Two inch [50.8 mm], throwaway filters shall be standard on all units. Compressors Units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gascooled and shall have a voltage utilization range of plus or minus 0 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. The compressor shall have external isolation to minimize noise. Refrigerant Circuits Each refrigerant circuit shall have orifice refrigerant control expansion device or TXV. Service pressure ports, shall be factory-installed as standard. Evaporator Coils and MicroChannel Condenser Coils Evaporator shall be internally finned, /8 [9.5 mm] copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Condenser coil shall be MicroChannel. Coils shall be leak tested at the factory to ensure pressure integrity. The evaporator coil and condenser coil shall be leak tested to 200 psig and pressure tested to 450 psig. A sloped condensate drain pan shall be standard and shall be removable. Outdoor Fans The outdoor fans shall be direct-drive statically and dynamically balanced, drawthrough in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fans All -phase units offer belt drive, FC centrifugal fans with adjustable motor sheaves. All motors shall be thermally protected. All indoor fan motors meet the U.S. Energy Policy Act of 992 (EPACT). Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Units shall provide an external location for mounting a fused disconnect device. 24-volt electromechanical control circuit shall include control transformer and contactor pressure lugs for power wiring. Unit shall have single point power entry as standard. Accessories/Option Roof CurbThe roof curb shall be designed to mate with the unit s downflow supply and return openings and provide support and a watertight installation when installed properly. The roof curb design shall allow field-fabricated rectangular supply/return ductwork to be connected directly to the curb. Curb design shall comply with NRCA requirements. Curbs shall be shipped knocked down for toolless field assembly and shall include wood nailer strips. EconomizerThis accessory shall be either field or factory-installed and is available with barometric relief standard. The assembly includes direct drive gear driver, fully modulating 0-00 percent motor and dampers, minimum position setting, mixed air sensor, wiring harness with plug, and single enthalpy control. Optional differential enthalpy control shall be field-installed. The factory-installed economizer arrives ready for operation. Remote PotentiometerField installed, the minimum position setting of economizer shall be adjusted with this accessory. Motorized Outside Air Dampers Field-installed manually set outdoor air dampers shall provide up to 50 percent outside air. Once set, outdoor air dampers shall open to set position when indoor fan starts. The damper shall close to the full closed position when indoor fan shuts down. Manual Outside Air DamperFactory or field-installed rain hood and screen shall provide up to 50 percent outside air. Oversized MotorsFactory installed belt drive oversized motors shall be available for high static applications. Powered ExhaustThe field installed powered exhaust, available for all units, shall provide exhaust of return air, when using an economizer, to maintain better building pressurization. 56

MECHANICAL SPECIFICATIONSRLKL-B SERIES Through the Base Electrical AccessAn electrical service entrance shall be factory provided allowing electrical access for both control and main power connection inside the curb and through the base of the unit. Option will allow for field installation of liquid-tight conduit and an external fieldinstalled disconnect switch. Through the Base Electrical with Disconnect SwitchFactory-installed -pole, molded case disconnect switch with provisions for through the base electrical connections are available. The disconnect switch will be installed in the unit in a watertight enclosure with access through a hinged door. Factory wiring will be provided from the switch to the unit high voltage terminal block. The switch will be UL/CSA agency recognized. Note: The disconnect switch will be sized per NEC and UL guidelines but will not be used in place of unit over current protection. Freeze/Clogged Filter SwitchesThis factory or field-installed option allows for individual fan failure or dirty filter protection. If indoor coil gets too cold due to low airflow, compressor operation will be temporarily interrupted. High Pressure CutoutHigh pressure cutout shall be standard on all models and /4 turn fasteners. All scroll compressors shall include Internal Pressure Relief as standard. ThermostatsTwo stage heating and cooling operation shall be available, for field installation, in either manual or automatic changeover. Automatic programmable electronic with night set back shall also be available. Differential EnthalpyAdds on to the standard single control with other enthalpy sensors that compare total heat content of the indoor air and outdoor air to determine the most efficient air source. This control option offers the highest level of comfort control, plus energy efficiency available. Low Ambient CoolingElectromechanical models have cooling capabilities to 40 F as built, or to 0 F by adding the optional low ambient (frostat) control. Enthalpy ControlSingle Enthalpy Control shall be standard for all economizers. Enthalpy control offers a higher level of comfort control, along with energy savings potential, than the standard dry bulb control. This is due to the additional wet bulb sensing capability. 57

WIRING SCHEMATICSRLKL-B SERIES 58