SERVICE BY QUALIFIED PERSONNEL ONLY

Similar documents
GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

ESRB and ESRN Installation & Safety Instructions

Bdl60u Fluorescent Emergency Ballast

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

Installation Instructions

HIGH BAY APPLICATIONS

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

CDL8 LED Architectural

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

INSTALLATION INSTRUCTIONS

WPLED 26W INSTALLATION INSTRUCTIONS

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

LED Emergency Battery Backup

Emergency Lighting Transfer System Model: ELTS2 Installation and User Operation Manual

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

Honeywell Durafit LED Retrofit Kit

USER GUIDE & INSTALLATION INSTRUCTIONS

Cold Deck Canopy and Shelf Lights and Retrofit Kit

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

EATON DFDAP-M / FDAP-M Remote Alarm Panels

USER GUIDE & INSTALLATION INSTRUCTIONS

BACKUP BATTERY INSTALLATION INSTRUCTIONS

USER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050

MaxLite LED Round Pendant Highbay Series

DHL-LP-LED Low Profile LED Linear High/Low Bay

Installation Instructions

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

SECTION LOW VOLTAGE LIGHTING CONTROLS

20W and 45W Dimmable LED Power Supply INSTALLATION GUIDE. Copyright ASP Holdings, Inc.

ARTEMIS Series of Low Occupancy LED Ceiling Mounted Fixtures (Including Stairwells) Installation & Operation Guide

Cold Door 2 LED Retrofit Kit Lighting System

Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

Installation Guide for models:

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Related Sections: TBD. Effective Date: January 1, 2016

Installation Guide for models:

DRC12FR DRC12FR347. Dynalite. Install Guide

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

LED IMPORTANT SAFETY INSTRUCTIONS

SP-1000X. Panic Device Power Controller Installation Guide. Rev


Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Installation Instructions

Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM

Installation Instructions

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Installation Instructions

LOSBAY800. BAY SENSOR Installation Manual. LOSBAY800 Specifications

Power Supply Display Module PSDM. Installation and Operation Manual

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

S5JB Quick Setup Guide. Refer to the instructions on the following pages for complete details on the steps outlined below.

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

XET-20 Series 20 Amp Emergency Lighting Control Device

P4200PM / P5000PM Remote Air Dryer User s Guide

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

Unison Echo Room Controller

RAM3 Remote Alarm Module

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

IN2 Lighting Control Devices

1 x4 Dimmable LED RetroFits

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

1 General Description

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Install Guide MXS-BRO SERIES SMALL BRO LED MULTIPLE RECESSED

MANUAL RESET ALARM RELEASE BOX

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

Operating Instructions

Installation Instructions

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Installation Instructions

P6500W Air Dryer User s Guide

MAXLITE RKT LED Retrofit Kit

PART 4 ELECTRICAL STANDARDS

PO Box 827 Hawley, MN (218) Fax (218)

TO-SK-1 Tip-Over Switch Kit For FSP-43 AND FSP-95

POWERFOIL X3.0 ELECTRICAL SPECS & DIAGRAMS

Series. Access Power Controllers. Installation Guide

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Transcription:

Installation Instructions Automatic Load Control Relay For Emergency Lighting! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. This product is for use with generator-supplied (or central inverter system-supplied) lighting loads. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 2. To reduce the risk of electric shock, disconnect all power sources before servicing. 3. This product is for field installation. 4. This product is for use in indoor or damp locations. 5. An unswitched, normal AC power source (120 through 277 VAC, 50/60 Hz) and a direct, separate connection to a generator-supplied or central inverter system-supplied emergency panel are required. 6. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 7. Do not use this product for other than intended use. 8. Servicing should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS CAUTION: THIS UNIT HAS MORE THAN ONE POWER SUPPLY CONNECTION POINT. TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT ALL POWER SOURCES BEFORE INSTALLING OR SERVICING THIS UNIT. SERVICE BY QUALIFIED PERSONNEL ONLY NOTE: BEFORE INSTALLING THE CONTROL DEVICE, MAKE SURE THAT THE NECESSARY BRANCH CIRCUIT WIRING IS AVAILABLE. AN UNSWITCHED SOURCE OF POWER IS REQUIRED. A SEPARATE CONNECTION TO A GENERATOR-SUPPLIED (OR CENTRAL INVERTER SYSTEM-SUPPLIED) CIRCUIT MUST ALSO BE PROVIDED. 06/05/15 Philips Emergency Lighting 236 Mt. Pleasant Rd. Collierville, TN 38017-2752 Tech Support 888-263-4638 Fax 901-853-5009 www.philips.com/bodine 70100252

CAUTION: THIS UNIT HAS MORE THAN ONE POWER SUPPLY CONNECTION POINT. TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT ALL POWER SOURCES BEFORE INSTALLING OR SERVICING THIS UNIT. NOTE: BEFORE INSTALLING THE CONTROL DEVICE, MAKE SURE THAT THE NECESSARY BRANCH CIRCUIT WIRING IS AVAILABLE. AN UNSWITCHED SOURCE OF POWER IS REQUIRED. A SEPARATE CONNECTION TO A GENERATOR-SUPPLIED (OR CENTRAL INVERTER SYSTEM-SUPPLIED) CIRCUIT MUST ALSO BE PROVIDED. STEP #1 MOUNTING THE > FAMILIARIZE YOURSELF WITH THESE INSTRUCTIONS BEFORE BEGINNING INSTALLATION. > Mount in a convenient location using appropriate hardware (not supplied). See Illustration 1 for typical installation. Do not mount with lid facing down. ILLUSTRATION 1 Wall Mounting STEP #2 INSTALLING THE > Disconnect AC power from all supply circuits. > Remove lid and install necessary conduit and wiring (not supplied) to the. > Refer to the illustrations on the following pages for proper wiring connections and choose the correct illustration for your application. > Note: When using Class 2 power limited circuits, (for example, 0-10 VDC dimming connections) remember to keep this wiring separate from high voltage wiring by using separate conduit and the enclosure knockout provided. > Replace lid and secure. 2

ILLUSTRATION 2 TERMINAL BLOCKS LOCAL SWITCHING MEANS as a Lighting Relay Control Device ILLUSTRATION 3 TERMINAL BLOCKS DIMMED TO CONTROL SWITCHED TO SWITCHED TO DIMMED as a Lighting Relay Control Device for a Dimming Rack *NOTE: Wire gauges for ALL leads terminating at T2 should be #18 AWG. Wire gauges for all other connections should be sized according to total connected lighting load. Ground unit using supplied green lead wire. 3

ILLUSTRATION 3 TERMINAL BLOCKS S1 S2 as a Lighting Relay Control Device with a Step Dimming System ILLUSTRATION 4 TERMINAL BLOCKS PURPLE GREY 0-10 VDC DIMMER TO BALLAST GREY LEADS TO BALLAST PURPLE LEADS LOCAL SWITCHING MEANS as a Lighting Relay Control Device with a 0-10 VDC Dimming System IF class 2 circuit, use knockout provided on enclosure and separate conduit to route these wires (see Note in Step #2 on page 2). *NOTE: Wire gauges for ALL leads terminating at T2 should be #18 AWG. Wire gauges for all other connections should be sized according to total connected lighting load. Ground unit using supplied green lead wire. 4

STEP #3 FOLLOW-UP & QUICK TEST OF THE INSTALLATION > Mark each designated emergency lighting fixture with the warning labels, 20 provided. > Apply AC power to all circuits. The green "Normal Power Present" and the red "Emergency Power Available" LED's should be illuminated. > Perform a quick test as described on the unit label to check for proper operation. When the test button is depressed, the green "Normal Power Present" LED should extinguish and the controlled lighting load should illuminate regardless of the local switch position provided emergency power is available (check red LED). > During a quick test using a with a dimming system, the lighting load should illuminate at full lumen levels when the test switch is depressed regardless of the lumen level during normal operation. > The entire generator (or central inverter) system, including all designated lighting loads, should be exercised to ensure proper operation (e.g., power up the generator, throw the transfer switch to the generator position, and check the lighting loads to verify they are operating properly from the generator supply). OPERATION The uses an internal relay contact to control the AC power feeding the lighting load. When the generator (or central inverter) supplies AC power to the lighting fixture, the bypasses the local switching means. This ensures the lighting load will be energized during generator (or central inverter) operation regardless of switch position. MAINTENANCE No routine maintenance is required to keep the functional. However, it should be checked periodically to ensure that it is working properly. Note: Make sure to disconnect both the normal and emergency panel circuit breakers before servicing.! REFER ANY SERVICING INDICATED BY THESE CHECKS TO QUALIFIED PERSONNEL! 5