Mobile Climate Control 7 MCC Reference Manual 0
Electric Condenser Model 0-00 -00 Air Flow Condenser V Condenser V -to support a cooling capacity of 00 Btu/hr (7770 W) -0 CFM (7 m /h) -. Amps/.V -0. Amps/7V - lbs. ( kg) made of /8GA (/.mm) Cold Rolled Steel finished in black semi-gloss epoxy powder coat. A -9-9 -078-7 -7-077 Cover Fan Assy. V Fan Assy. V Venturi The 0 is an excellent light duty application condenser. It provides the option of deck or roof mounting. B C 7-079 -0-0 8-000 8-00 -08 Fan Motor Assy. V Motor Assy. V Finger Guard Electric condensers are used when radiator mounted types cannot be installed. The reasons being insufficient air flow and/or when additional heat load over the engine cannot be tolerated. Mobile Climate Control 7 MCC Reference Manual 0
Electric Condenser Model 0 Electrical Connections -way male weather pack connector, packard #0097 (MCC #-08) with male terminal #8-L (x) (MCC #-09) and seal #009 (X) (MCC #-0) Electrical Connections -way deutsch plug DT0 - S (MCC #-) with #WS wedge (MCC #-) and contacts /Ga #0-09- (MCC #-) -00-00 Airflow Condenser V Condenser V -To support a cooling capacity of 9700 Btu/hr (8700 W) -0 CFM (90 m /h) -9. Amps (at.v) -9 amps (at 7V) -8.7 lbs (kg) Note: made of GA satin coat steel, endplates made of GA satin coat steel and both finished in black semi gloss epoxy powder coat. A B The 0 is a compact high performance condenser. - -0-70 -70-077 -078 Fan Assembly V Fan assembly V Venturi Fan C D E -0778-09 9-0 9-097 Motor V Motor V #0- Hex. Socket C Clip Electrical condensers are used when radiator mounted types cannot be installed. The reasons being insufficient air flow and /or when additional heat load over the engine cannot be tolerated. Mobile Climate Control 7 MCC Reference Manual 0
Electric Condenser Model 0 Electrical Connections: -way male weather pack connector, packard #0097 (MCC #-08) with male terminal #8-L)(x) (MCC #-09) and seal #009 (x) (MCC #-0) -0 Condenser V C -0 Condenser V Air Flow -to support a cooling capacity of 90 Btu/hr (8700 W) -0 CFM (90 m /h) -7 Amps (.V) -8. Amps at (7V) -8. lbs. ( kg) made of GA (.mm) Satin Coat Steel. Endplates made of GA (mm) Satin Coat Steel. Both are finished in black semi-gloss epoxy powder coat. A B -89-0 -7-7 -077-079 Fan Assy. V Fan Assy. V Venturi Fan Items and have to be ordered separately. The 0 is a compact, high capacity unit. Its compact design allows for wall or flush mounting applications in engine compartments. A motor with longer life than in the 0 is used in this condenser which makes it slightly deeper. D E -07-07 9-0 9-07 -08-9 -0 Motor V Motor V #0 - HEX. Socket CTR.Sunk C clip Finger Guard Bracket, Left (Opt.) Bracket, Right (Opt.) Electric condensers are used when radiator mounted types cannot be installed. The reasons being insufficient air flow and /or when additional heat load over the engine cannot be tolerated. Mobile Climate Control 7 MCC Reference Manual 0
Electric Condenser Model 0-0 -0 Air Flow Condenser V Condenser V -to support a cooling capacity of 00 Btu/hr (9 W) -90 CFM (0 m /h) - Amps/.V -7 Amps /7V -0 lbs. (. kg) made of GA (.mm) and mounting brackets of GA (mm) Cold Rolled Steel finished in black semi-gloss epoxy powder coat. 7 8 9 0-0 -09-99 -998-009 -0-0 -0-0 -070-090 Cover Mounting Bracket (L) Mounting Bracket (R) Venturi Assy. Motor Support Receiver Drier Bracket Mount Motor V Motor V The 0 is a deck or roof mount condenser that has the receiver/drier mounted internally. The hose can exit either side of the 0. Condenser must be mounted as shown in picture. 7 8 9 0-008 -0-09 -0-00 -0 7-088 8-000 8-00 7-00 -0 Fan Relay V Relay V Socket, Relay Receiver Drier Pressure Switch Refr. Hose Assy. # Snap-in Plug O-Ring # Wiring Harness Electric condensers are used when radiator mounted types cannot be installed. The reasons being insufficient air flow and /or when additional heat load over the engine cannot be tolerated. Mobile Climate Control 7 MCC Reference Manual 0
Electric Condenser Model 07 The 07 is a larger capacity version of the 0. With the receiver/drier mounted internally, installation time is minimized. Condenser must be mounted as shown in picture. Mobile Climate Control 7 MCC Reference Manual 0
Electric Condenser Model 08-08 -08 Air Flow Condenser V Condenser V -to support a cooling capacity of 9000 Btu/hr (800 W) -00 CFM (78 m /h) -0 Amps/.V -0 Amps/7V -7 lbs. (. kg) made of GA (.mm) and mounting bracket of GA (mm) Cold Rolled Steel finished in black semi-gloss epoxy powder coat. 7 8 9 0-09 -09-09 -097-0 -08-090 -008-0 -0-009 Cover Side Cover Receiver Drier Bracket Motor V Motor V Fan C.C.W. Motor Mount Motor Support Venturi Assy. The 08 was designed for large capacity requirements in the forestry, construction and mining industries. Its three fan design ensures high capacity performance in the most demanding conditions. Receiver/drier mounted internally. Condenser must be mounted as shown in picture. 7 8 9 0-09 -097-008 7-07 7-00 8-000 8-000 -00 8-00 8-00 Receiver Drier Mount Pressure Switch Refrigerant Hose # O-Ring # Wiring Harness Snap-in Plug Snap-in Plug Electric condensers are used when radiator mounted types cannot be installed. The reasons being insufficient air flow and /or when additional heat load over the engine cannot be tolerated. Mobile Climate Control 77 MCC Reference Manual 0
Electric Condenser Model 09-090 -090 Air Flow Condenser V Condenser V -to support a cooling capacity of 800 Btu/hr (80 W) -00 CFM (870 m /h) - Amps/.V -7 Amps/7V - lbs. ( kg) made of GA (.mm) Cold Rolled Steel finished in black semi-gloss epoxy powder coat. -97-9 -98-009 -088-0 Grill Cover Venturi Motor Support 7 8 9 0-0 -08-070 -090-0 8-00 Motor Mount Fan Motor V Motor V Wiring Harness Electric condensers are used when radiator mounted types cannot be installed. The reasons being insufficient air flow and/or when additional heat overload the engine cannot be tolerated. The 09 is a universal mount electric condenser. It does not have the receiver/drier mounted internally. This allows for many different installation options. Condenser can be mounted vertically or horizontally. Mobile Climate Control 78 MCC Reference Manual 0
Electric Condenser Model 0-00 -00 -to support a cooling ca- pacity Air Flow Condenser V Condenser V of 00 Btu/hr(00 W) -900 CFM (0 m /h) - Amps/.V - Amps/7V - lbs. (9. kg) made of GA (.mm) Cold Rolled Steel and finished in black semi-gloss epoxy powder coat. 7 8 9 0-09 -09-097 -098-099 -088-070 -09-00 -09-0 -09-09 Cover Fan Mounting Plate Cover Plate Receiver Drier Bracket Motor V (B.B.) Motor V (B.B.) Fan Motor Bracket Motor Mount Motor Support Receiver Drier The 0 was designed for high capacity off-road applications. Its large design has flexible hose routing options. The receiver/drier is mounted internally. Condenser must be mounted as shown in picture. 7 8 9 0-008 -0-09 -0 7-079 7-00 8-007 -09 8-00 8-000 8-00 7-00 Pressure Switch Relay V Relay V Socket Refrigerant Hose # O-Ring # Vibration Mount Wiring Harness Plastic Plug Hose Clamp # Electric condensers are used when radiator mounted types cannot be installed. The reasons being insufficient air flow and /or when additional heat load over the engine cannot be tolerated. Mobile Climate Control 79 MCC Reference Manual 0
Electric Condenser Model.8 AIR FLOW M8 x. ( x ) K.. 7. 0.0..8.0 PED WP -WAY SHROUD CONNECTOR DELPHI PACKARD #0097 7.0 GND - BLACK CGND - WHITE D C B A UN - RED PWM / LI - BLUE = Part no. No. Part No. Description No. Part No. Description -0 Condenser V Heating Air flow.000 Btu/hr 000 CFM.0 AMPS 0.7KG (.8KG with mounting brackets and mtg. fastners) 7 8 9 0-8 -0-00 -0-0 -0-0 -089-008 -9 CONDENSER Receiver Bracket Condenser Condenser Supp. Back Condenser Supporter Receiver Support Condenser Cover Fan EBM V Receiver Drier MCC Label for -0 7 8 9 0 7-008 7-00 7-8-0 8-08 9-0 9-000 9-0 9-00 9-0 9-0 9-07 9- - -80 9- P-Clamp #08 O-Ring # Gear Clamp " Plastic Cap # Plastic Cap #8 Pop Rivet /"x." Washer M SS Washer M SS Bolt Mx0 SS Bolt Mx SS Washer M S.S. Bolt Mx SS Lock Washer M Conduit /8" L=00mm Copper Tube /8" M8 LOCKNUT w/nylon IN Mobile Climate Control 80 MCC Reference Manual 0
Condensors Radiator Mount MCC s heavy duty radiator mounted condensers are the least expensive alternative compared to forced air types. They are manufactured in-house using 0.008-0.00 (0.0mm-0.mm) thick aluminum fins and copper tubes. With endplates made of GA (.mm) Satin Coat Steel. Waved or corrugated fins are available, as indicated on the drawings. In addition to the heavy fin thickness, the edges are rippled, increasing the strength further. Low fin density makes cleaning easier and provides less pressure drop. Please keep in mind that the MCC condensers are developed for off-road environments. Condensers are painted black. In and outlet tubes are reinforced with metal brackets where required. All coils are pressure tested to a minimum of 00 psi (. MPa). -0089 Condenser -07 Condenser -00 Condenser Note: based on 00 F (8 C) air temp. and 0 F (0 C) condensing temp. Inlet -/- UNF Male (O-Ring #8) Outlet -/8-8 UNF Male (O-Ring #) Mobile Climate Control 8 MCC Reference Manual 0
Condensors Radiator Mount -000 Condenser -0 Condenser -0 Condenser Note: based on 00 F (8 C) air temp. and 0 F (0 C) condensing temp. Inlet -/- UNF Male (O-Ring #8) Outlet -/8-8 UNF Male (O-Ring #) Mobile Climate Control 8 MCC Reference Manual 0