Field changeable between Trimmed / Trimless / Millwork

Similar documents
USAI. Basic Dimming Compatibility. BeveLED Mini. Lighting. Precision Lighting. Color Harmony River Road New Windsor, NY 12553

Field changeable between Trimmed / Trimless / Millwork

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED BLOCK Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

USAI ADJUSTABLE. Lighting

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

DATE TYPE 40 DELIVERED PERFORMANCE

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

80 Watts FLANGE FINISH

PROJECT INFORMATION PROJECT

SliverLED Round Downlight, 1 Regress SR11

SliverLED Round Adjustable, Wet Location SR21W

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

PROJECT INFORMATION FLANGE FINISH

OPTIONAL LENS 2 FLANGE FINISH

PROJECT INFORMATION LENS. S Solite F Frosted C Clear N No Glass. New Construction CP Chicago Plenum 35KS 3500K, 80+ CRI.

PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT DATE TYPE. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

PROJECT INFORMATION PROJECT DATE TYPE

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN10RAT - BM- MTG214-27KS LNC61-120V - DIML2 - CB27 - BOFD

BeveLED 2.1 PROJECT INFORMATION

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

BeveLED. 2.2 Retrofit 4.5 Round Downlight - B4RDRT B4RDRT. usailighting.com/beveledrt

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts ADJUSTABLE

PROJECT INFORMATION PROJECT DATE TYPE

NanoLED NXT Cylinder LNRP3 Surface

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN25RDT - BM- MTG214-27KS LSP55-120V - DIML2 - CB27 - BOFC COLOR

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

1" Regress Trim DELIVERED PERFORMANCE - Downlight

True Zero Conceal - Z3SA-C 3 Square Adjustable

BeveLED Cylinder LBRP6 Surface

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

ARMSTRONG INTERSECTION DOWNLIGHTING KIT

Field Convertible from Trimless or Millwork to Trimmed. Trimmed - B3SCF Trimless - B3SCL Millwork - B3SCM

PROJECT DATE LENS. S Solite (provided standard) F Frosted. S Solite (provided standard) F Frosted HOUSING TYPE REFLECTOR

BeveLED Cylinder LBRP6 Pendant

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

BeveLED Mini Trimless Acoustical - B3RDP

BeveLED Mini - B3SD 3 Square Downlight

Deep Regress - B4RC usailighting.com/b4rc LED COLOR CHOICES. Classic White

BeveLED Mini - B3RA 3 Round Adjustable

Universal and Field Convertible - Trim Trimless Millwork. Downlight - B4SD usailighting.com/b4sd LED COLOR CHOICES. Classic White

BeveLED Mini - B3RD 3 Round Downlight

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Nova NFTV (0-10V)* 100%-10% 1-30 ** 1-30* Nova T NTFTV (0-10V)* 100%-10% 1-30 ** 1-30* Lutron ZT. Diva DVTV (0-10V)* 100%-10% 1-30 ** 1-30* Standard

ELEMENT LED Dimmer Compatibility Testing

IHOL-4DR / IRD400 4 Gravity LED Downlight

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Micro Wall Wash Trimless - MWL

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

Evoke Round Adjustable C3

Classix 6" 6" Round Adjustable C3

Evoke Square Adjustable HP

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

IHOL-6DR / IRD600 6 Gravity LED Downlight

Evoke Square Adjustable HP

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Evoke 2.9" HP. 2.9" Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

LED Drivers & Dimmers

Velato. Recessed Slot Adjustable Multiples

Classix 6" 6" Round Adjustable C3M

Hornet HP. Semi-Recessed 4-Light Square Multiple

Evoke Square Adjustable C3M

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Essenza. Square Downlights

Essenza. Round Downlights

RFP Grand Entry Canopies Addendum 002 Issued July 16, 2013

Evoke Square Downlight

Evoke Square Downlight

Classix 6" 6" Round Adjustable C3

Classix 6" 6" Round Lens Wall Wash

Hornet HP. Recessed 4-Light Square Multiple

Grüv Flare Regressed. Recessed Linear LED

Evoke Square Downlight

Performance Chart Electrical Data

Transcription:

BeveMini Basic - B3RA-L2 3 Round Adjustable Field changeable between Trimmed / Trimless / Millwork Trimmed - B3RAF Trimless - B3RAL Millwork - B3RAM usailighting.com/minibasic Introducing Beve Mini Basic, our newest downlight to deliver consistently classic white light with the same below ceiling appearance as our Beve Mini product line. FEATURES 2700K, 3000K, or 3500K color temperature options Downlight, wallwash and adjustable accent configurations Dry/damp/wet location rated for bathrooms and showers All of s dimming driver options including 0-10V, digital, and phase dimming All housings are field convertible from trimless or millwork to trimmed installations in the field BEVE MINI BASIC ADJUSTABLE PERFORMANCE DATA DELIVERED PERFORMANCE: Classic White 15W Color Temperature: 2700K 3000K 3500K Color Rendering Index: 80+ 90+ 80+ 90+ 80+ Source Lumens: 1500 1250 1575 1275 1575 Lumens Per Watt: 55 46 58 47 58 Delivered Lumens: 875 725 900 750 900 Color Consistency: 2-Step MacAdam Ellipse Page 1 usailighting.com 2017., LLC. Covered by US Patents: 7,832,889 and 8,469,536. Patents pending. and Beve Mini are registered trademarks of, LLC. Revised 2/02/2018

HOW TO SPECIFY BeveMini Basic - B3RA-L2 3 Round Adjustable Specify fixture part number. (All boxes must be filled in to correctly order) B3RA 15L2 25 Trim Style B3RAF 3 Round Adjustable Overlap Flange B3RAL 3 Round Adjustable Trimless Plaster Frame B3RAM 3 Round Adjustable Trimless Millwork Wattage Classic White 15L2 15W Color Temperature 27KS 2700K, 80+ CRI 27KH 2700K, 90+ CRI 30KS 3000K, 80+ CRI 30KH 3000K, 90+ CRI 35KS 3500K, 80+ CRI 2-Step MacAdam Ellipse Color Consistency is standard for all Beam 25 25o beam Lens S Solite (provided standard) BF Borosilicate Frosted Trim Finish WH White GR Grey BL Black BZ Bronze PR Primer Finish RAL Custom Color Specify RAL # Housing NCIC New Construction Insulation Contact Rated / Airtight NCCP Chicago Plenum NCEM New Construction Emergency Battery Voltage Select one UNV 120V-277V 120V Dimming Driver For use with Universal Voltage 120V - 277V D2 0-10V dim, 10% (provided standard) D4 Lutron 3-wire/ECO, 1% D6A Eldo 0-10V, 0.1% D6B Eldo 0-10V, 0.1% D6E Eldo 0-10V, 1% D6F Eldo 0-10V, 1% D7 Eldo DALI, 0.1% For use with 120V only D3 Lutron 2-wire, 1% D19 Phase 2-wire, 1% D21 ERP Phase dimming, 1% Accessories (Optional) CB27 27 C-Channel Bars CB52 52 C-Channel Bars TRIM FINISH OPTIONS White - WH Grey - GR Primer finish and custom colors also available Black - BL Bronze - BZ Beve Mini Basic Optical Accessories Matrix if you want add lens 30 beam AL20D 35 beam AL30D 40 beam AL40D 45 beam AL55D 55 beam AL80D Hexcell louver HEXD order separately BEVE MINI BASIC SPECIFICATIONS FIELD REPLACEABLE LIGHT ENGINE is serviceable through the aperture with a Philips screwdriver. All light engines feature industry-leading color consistency within a 2-Step MacAdam Ellipse. ADJUSTMENT True hot aiming with center beam optics is adjustable, with a completely tool-less mechanism. 0-40 lockable vertical tilt with 362 lockable rotation. FIELD REPLACEABLE Unless otherwise specified, a 0-10V, 100%-10% solid state electronic constant current integral D2 dimming driver with a high power factor is provided standard and sources 2mA. All dimming drivers are serviceable from below the ceiling through the aperture and comply with IEEE C62.41 surge protection. EMERGENCY Emergency housing fixtures are provided with a remote test switch with a 24 lead length for location of the test switch. Emergency battery requires above ceiling access for service. WEIGHT Beve Mini Basic NCIC and NCCP housings weigh 11 lbs each. NCEM housing weighs 15 lbs. ACCESSORY HOLDER Snap in accessory holder shipped with fixture accepts 1 optical accessory maximum, size D. Optical accessories are specified and ordered separately per table above. HOUSING Fabricated of 20 ga. steel construction with thru wire J-box, 4 in 4 out at min. 90 C, #12 AWG thru branch circuit wiring. MOUNTING B3RAF overlap flange fixtures are designed for use in sheetrock, acoustical ceiling tile, and many other ceiling materials. B3RAL plaster frame fixtures are provided with a spackle collar and are designed for use in sheetrock/mud-in ceiling applications. B3RAM millwork fixtures are provided with a millwork collar and are designed for use in wood/millwork construction applications. Butterfly brackets and adjustable nailer bars extendible from 14 to 24 centers with integral nails are provided for attachment to building structure. C-channel bars are optionally available for acoustical ceiling applications. WARRANTY Based on IESNA LM80-2008, Beve Mini Basic has a 50,000 hour rated life at 70% lumen maintenance (L70). Warranty covers replacement parts for 5 years from date of shipment. CEILING CUT OUT B3RAF Overlap Flange: 3-5/8 Ø B3RAP Plaster Frame: 4-3/16 Ø B3RAM Millwork: 3-5/8 Ø MAXIMUM CEILING THICKNESS As noted on housing drawings LISTINGS Dry/Damp/Wet location. UL2043 rated for use in air handling plenums. Not for use in fire-rated installations. NRTL/CSA-US tested to UL standards. IBEW union made. NOTES Not for use in corrosive environment Use of pressure washer voids warranty PHOTOMETRICS Consult factory or website for IES files. Tested in accordance with IESNA LM79. Page 2 usailighting.com 2017., LLC. Covered by US Patents: 7,832,889 and 8,469,536. Patents pending. and Beve Mini are registered trademarks of, LLC. Revised 2/02/2018

BeveMini Basic - B3RA-L2 3 Round Adjustable TRIM DETAILS Trimmed - B3RAF Trimless - B3RAL Millwork - B3RAM 1 Regress 1 Regress 1 Regress 1/8 Bevel Finish Bevel Finish Bevel Finish Flange Finish Millwork Collar Finish 3 Ø 4 Ø 3 3 /8 Ø 3 3 /8 Ø 3 5 /8 Ø HOUSING OPTIONS Trimmed - B3RAF Insulation-Contact Rated/Airtight - NCIC Chicago Plenum Housing - NCCP Emergency Housing - NCEM Trimless - B3RAL Insulation-Contact Rated/Airtight - NCIC Chicago Plenum Housing - NCCP Emergency Housing - NCEM Millwork - B3RAM Insulation-Contact Rated/Airtight - NCIC Chicago Plenum Housing - NCCP Emergency Housing - NCEM 5 1 /2 5 1 /2 5 1 /2 19 1 /8 1 max. ceiling thickness 19 1 /8 1 max. ceiling thickness 19 1 /8 1 max. ceiling thickness 6 7 /8 6 7 /8 6 7 /8 10 1 /8 10 1 /8 10 1 /8 EM for OPTIONAL NCEM Housing EM Only 1 9 /16 EM for OPTIONAL NCEM Housing EM Only 1 9 /16 EM for OPTIONAL NCEM Housing EM Only 1 9 /16 Page 3 usailighting.com 2017., LLC. Covered by US Patents: 7,832,889 and 8,469,536. Patents pending. and Beve Mini are registered trademarks of, LLC. Revised 2/02/2018

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D2 / DIML2 D2 / DIML2 : 0-10V Dimming Driver Wiring (Dims down to 10%) D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V / 277V Use source current per Crestron ilux dimmer expansion module CLS-EXP-DIMFLV 100% - 10% fixture specification Crestron DIN Rail dimmer DIN-4DIMFLV4 100% - 10% sheet to determine Crestron DIN Rail analog output module DIN-A08 100% - 10% number of fixtures per Crestron 8 Channel dimmer module GLX-DIMFLV8 100% - 10% dimmer. Max number Crestron 8 Channel dimmer module GLXP-DIMFLV8 100% - 10% of fixtures is limited by Leviton IllumaTech dimmer IP710-DLX 100% - 10% dimmer load rating. Lightolier (Philips) Vega V2000FAMU 100% - 10% Lutron Diva DVTV-XX 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIMMER: 0-10V D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER 0-10V (-) 0-10V (+) GRAY NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIMMER: 0-10V w/ POWER SWITCHING D2 / DIML2 0-10V DIMMING (NO RELAY) 0-10V (-) 0-10V (+) GRAY NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. 2016., LLC. I2-264-2 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D3 / DIML3 D3 / DIML3 : Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / Dimming Driver Wiring (Dims down to 1%) 120V D3 / DIML3 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Dimmer* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet ELV10 100% - 1% 1 26 1 13 ETC Unison DRd Cabinet ELV10 100% - 1% 1 26 1 13 Lutron Maestro Wireless 600W dimmer MRF2-6ND-120-100% - 1% 1 8 1 4 Lutron Maestro Wireless 1000W dimmer MRF2-10ND-120-100% - 1% 1 13 1 6 Lutron HomeWorks QS adaptive dimmer HQRD-6NA- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 600W dimmer HQRD-6ND- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 1000 W dimmer HQRD-10ND- 100% - 1% 1 13 1 6 Lutron Caseta Wireless Pro 1000W dimmer PD-10NXD- 100% - 1% 1 13 1 6 Lutron Stanza dimmer SZ-6ND- 100% - 1% 1 8 1 4 Lutron RadioRA 2 adaptive dimmer RRD-6NA- 100% - 1% 1 8 1 4 Lutron RadioRA 2 1000 W dimmer RRD-10ND- 100% - 1% 1 6 1 3 Lutron myroom DIN power module MQSE-4A1-D 100% - 1% 1 6 1 3 Lutron HomeWorks QS wallbox power module HQRJ-WPM-6D-120-100% - 1% 1 26 1 13 Lutron Homeworks DIN power module LQSE-4A1-D 100% - 1% 1 6 1 3 Lutron HomeWorks wallbox power module HWI-WPM-6D-120 100% - 1% 1 26 1 13 Lutron GRAFIK Eye QS control unit QSGR-, QSGRJ- 100% - 1% 1 26 1 13 Lutron GRAFIK Eye 3000 control unit GRX-3100-, GRX-3500-100% - 1% 1 26 1 13 Lutron RPM-4U module HW-RPM-4U-120, LP-RPM-4U-120 100% - 1% 1 26 1 13 Lutron RPM-4A module HW-RPM-4A-120, LP-RPM-4A-120 100% - 1% 1 26 1 13 Lutron GP dimming panels Various 100% - 1% 1 26 1 13 Lutron Ariadni CL 250W dimmer AYCL-253P- 100%-1% 1 8 1 4 Lutron Diva CL 250W dimmer DVCL-253P-, DVSCCL-253P- 100%-1% 1 8 1 4 Lutron Grafik T CL or RF CL dimmer GT-250M-, GTJ-250M- 100%-1% 1 8 1 4 Lutron Nova T CL 250W dimmer NTCL-250-100%-1% 1 10 1 5 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D3 / DIML3 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE ONLY FOR SWITCHES WITH 2016., LLC. I2-264-3 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D4 / DIML4 D4 / DIML4 : Lutron Hi-Lume A-Series Driver with 3-Wire FL Control / Dimming Driver Wiring (Dims down to 1%) D4 / DIML4 3-Wire Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet D20 Dimming module 100% - 1% 1 53 1 26 ETC Unison DRd Cabinet D20F Dimming module 100% - 1% 1 53 1 26 Lutron Nova T NTF-10-100% 1% 1 41 1 20 Lutron Nova T NTF-103P- 100% 1% 1 20 1 10 Lutron Nova NF-10-100% 1% 1 41 1 20 Lutron Nova NF-103P- 100% 1% 1 20 1 10 Lutron Vareo VF-10-100% 1% 1 20 1 10 Lutron Skylark SF-10P-, SF-103P- 100% 1% 1 20 1 10 Lutron Diva DVF-103P-, DVSCF-103P- 100% 1% 1 20 1 10 Lutron Ariadni AYF-103P- 100% 1% 1 20 1 10 Lutron Vierti VTF-6A- 100% 1% 1 15 1 7 Lutron Maestro MAF-6AM-, MSCF-6AM- 100% 1% 1 15 1 7 Lutron Maestro Wireless MRF2-F6AN-DV- 100% 1% 1 15 1 7 Lutron RadioRA 2 RRD-F6AN-DV- 100% 1% 1 15 1 7 Lutron HomeWorks QS HQRD-F6AN-DV 100% 1% 1 15 1 7 Lutron Interfaces PHPM-3F-120, PHPM-3F-DV 100% 1% 1 41 1 20 Lutron GP Dimming Panels Various 100% 1% 1 41 1 20 277V Only 40W and Less 41W - 80W ETC Sensor+ Cabinet D20 Dimming module 100% - 1% 1 53 1 26 ETC Unison DRd Cabinet D20F Dimming module 100% - 1% 1 53 1 26 Lutron Nova T NTF-10-277- 100% 1% 1 44 1 22 Lutron Nova T NTF-103P-277-100% 1% 1 33 1 16 Lutron Nova NF-10-277- 100% 1% 1 44 1 22 Lutron Nova NF-103P-277-100% 1% 1 33 1 16 Lutron Skylark SF-12P-277-, SF-12P-277-3 100% 1% 1 33 1 16 Lutron Diva DVF-103P-277-, DVSCF-103P-277-100% 1% 1 33 1 16 Lutron Ariadni AYF-103P-277-100% 1% 1 44 1 22 Lutron Vierti VTF-6A- 100% 1% 1 33 1 16 Lutron Maestro MAF-6AM-277-, MSCF-6AM-277-100% 1% 1 20 1 10 Lutron Maestro Wireless MRF2-F6AN-DV- 100% 1% 1 33 1 16 Lutron RadioRA 2 RRD-F6AN-DV- 100% 1% 1 33 1 16 Lutron HomeWorks QS HQRD-F6AN-DV 100% 1% 1 33 1 16 Lutron Interfaces PHPM-3F-DV 100% 1% 1 88 1 44 Lutron GP Dimming Panels Various 100% 1% 1 88 1 44 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 wiring diagrams continued on next page 2016., LLC. I2-264-4 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D4 / DIML4 Continued D4 / DIML4 : Lutron Hi-Lume A-Series Driver with 3-Wire FL Control / Dimming Driver Wiring (Dims down to 1%) DIMMER: 3 WIRE PHASE DIMMED HOT D4 / DIML4 3 WIRE PHASE DIMMING CAP UNUSED ECOSYS WIRES GRAY ORANGE D4 / DIML4 : Lutron Hi-Lume A-Series Driver with EcoSystem Control / Dimming Driver Wiring (Dims down to D4 / DIML4 EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 100% 1% 1 32 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 100% 1% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 100% 1% 1 64 1 32 Lutron Quantum Various 100% 1% 1 64 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. E2 E1 D4 / DIML4 EcoSystem CONTROLS ECOSYS BUS E2 E1 WALL CONTROL CAP UN-USED ORANGE WIRE GRAY ORANGE 2016., LLC. I2-264-4 Revised 03/22/2017

DIMMING COMPATIBILITY D6A / DIML6A and D6E / DIML6E D6B / DIML6B and D6F / DIML6F D6A / DIML6A and D6E / DIML6E Dimming Compatibility Table D6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., Lutron and others listed in the table below) D6A / DIML6A = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6E / DIML6E = Eldo ECOdrive 0-10V control dims from 100% to 1% D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6A 6E Refer to manufacturer's Lutron Diva DVTV/NFTV with PP-20 99% - 0.1% 1% dimmer load rating for Lutron Nova T NTFTV with PP-20 99% - 0.1% 1% maximum and minimum Lutron Energi Savr Node QSN-4T16-S 100% - 0.1% 1% fixture quantities per Lutron GP Dimming Panels TVM2 Module 99% - 0.1% 1% dimmer. Lutron Interfaces GRX-TVI w/ GRX3503 100% - 0.1% 1% Enlighted compatible. Sensor Switch nio nio EZ 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D6B / DIML6B and D6F / DIML6F Dimming Compatibility Table D6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g., Crestron, non-lutron and others listed below) D6B / DIML6B = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6F / DIML6F = Eldo ECOdrive 0-10V control dims from 100% to 1% D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6B 6F Bush-Jaeger Electronic potentiometer 2112U-101 100% - 0.1% 1% Jung Electronic potentiometer 240-10 100% - 0.1% 1% Leviton Iluma Tech dimmer IP710-DLX 100% - 0.1% 1% Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 100% - 0.1% 1% Merten Electronic potentiometer 5729 100% - 0.1% 1% Pass & Seymour Titan CD4FB-W 100% - 0.1% 1% Watt Stopper Miro DCLV1 100% - 0.1% 1% Synergy Wallbox Dimmers ISD BC 100% - 0.1% 1% ABB i-bus SD/S 2.16.1 100% - 0.1% 1% Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 100% - 0.1% 1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8-100% - 0.1% 1% Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 100% - 0.1% 1% Crestron DIN Rail Analog Output Module DIN-A08 100% - 0.1% 1% Crestron DIN Rail 0-10V Fluorescent Dimmer DIN-4DIMFLV4 100% - 0.1% 1% Crestron ilux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1% Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. DIMMING WIRING SCHEMES: not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. CLASS 2 CONTROL WIRES DIMMER: 0-10V RELAY DIMMER: 0-10V w/ POWER SWITCHING D6 / DIML6 0-10V DIMMING W/RELAY TO SWITCH POWER 0-10V (-) 0-10V (+) GRAY DIML6A, 6B 0-10V DIMMING (NO RELAY) DIMMER: 0-10V w/ POWER SWITCHING 0-10V (-) 0-10V (+) D6 / DIML6 0-10V DIMMING (NO RELAY) GRAY 2016., LLC. I2-264-6 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D7 / DIML7 and D7E D7 / DIML7 and D7E Dimming Driver Wiring D7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = Eldo SOLOdrive DALI control dims from 100% to 0.1% D7E = Eldo ECOdrive DALI control dims from 100% to 1% D7 / DIML7 / D7E DALI CONTROLS DALI BUS DA DA WALL CONTROL ORANGE (-) ORANGE/ (+) 2016., LLC. I2-264-7 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D19 / DIML19 D19 / DIML19 : Hatch XTC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load. 120V only. D19 / DIML19 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE ONLY FOR SWITCHES WITH D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton IPL06-10Z Use fixture wattage per 6613-xxx fixture specification Lutron S-600P sheet to determine S-603P number of fixtures DV-600P per dimmer. Max number DV-603P of fixtures is limited by DVSC-603P dimmer load rating. CT-600P CT-603P 120V ONLY Reverse Phase / ELV Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton 6615 Use fixture wattage per IPE04-xxx fixture specification Lutron NTELV-300 sheet to determine NTELV-600 number of fixtures SELV-300P per dimmer. Max number SELV-303P of fixtures is limited by DVELV-300P dimmer load rating. DVELV-303P 2016., LLC. I2-264-19 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D21 D21 : ERP EBR015 series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load (see compatibility chart below). Dimmable at 120V only. D21 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE ONLY FOR SWITCHES WITH D21 Dimmer Compatibility Chart 120V ONLY PHASE DIMMING Dimmer Information Dimming Range Qty Fixtures Manufacturer Product Maximum Minimum Per Dimmer DAL06P 100% 0% Cooper DLC03P 100% 0% SLC03P 100% 0% 6161 99% 10% 6631-2 100% 0% 6633-P 100% 0% Leviton 6673-10W 99% 6% 6683-IW 100% 2% IPE04 100% 3% IPI06-1LZ 99% 0% VPE06 100% 5% Lightolier ZP260QEW 99% 3% CT103P 99% 6% DV600P 99% 3% DVCL-153P 99% 0% DVELV303P 97% 3% FAELV500 99% 7% LG600P 99% 5% Lutron MAELV600 99% 7% S600P 99% 1% S-603PG 86% 4% SELV300P 97% 3% TG-600P 99% 13% TGCL-153P 99% 2% Use fixture wattage per fixture specification sheet to determine maximum number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating per dimmer specification sheet. 2017., LLC. I2-264-21