evohome Sundial pack Thermostat Installation
Overview Honeywell is providing two pre-configured packs: Sundial pack and evotouch Thermostat. evohome Sundial pack This pack is suitable for S plan and Y plan systems with domestic hot water control. It comprises the following devices that are necessary to control heating and domestic hot water: Heating relay BDR91 Domestic hot water relay BDR91 Domestic hot water sensor CS92A All devices are pre-configured with the evotouch to control heating and domestic hot water: Non pre-configured devices With non pre-configured devices such as HR80UK you can configure the system by following the instructions of the GUIDED CONFIGURATION for all mentioned applications. Note: The configuration is dependent on the application you are selecting. Components The CS92A hot water sensor is wireless, comprising of a transceiver unit and a strap-on sensor with 1.5 m of cable. It operates on 2 x AA alkaline batteries, giving a battery life of at least 2 years under typical operating conditions. evotouch Thermostat This pack is specific for a Combi boiler system without domestic hot water control. It is already pre-configured with the BDR91 boiler relay without domestic hot water control, see Application 3: Combi boiler on page 5. However, it can be upgraded later on in the field to control domestic hot water as S plan or Y plan system as well. To change system configuration: See Upgrade application 3: Combi boiler with domestic hot water on page 6. The BDR91 relay module is a wireless relay module with change over contact 5 A and transceiver 868 MHz. 2
Installation overview Application 1: Sundial S plan system evotouch DHW Heating ENGISH Junction Box V4043 V4043 Pump Radiators Boiler DHW Cylinder Sundial S plan wiring plan NOTE: 1. It is recommended that either the 10 way junction box or Sundial Wiring Centre should be used to ensure first time, fault free wiring. 2. If using the V4043H1080 (1 BSP) or V4043H1106 (28mm), the white wire must be electrically isolated. 230V 50Hz 3A RATED N E GREY GREY BUE BROWN G/YEOW V4043H ZONE VAVE HTG MOTOR G/YEOW HTG RECEIVER BDR91 N A B DHW BUE RECEIVER BDR91 N A B BROWN ORANGE V4043H ZONE VAVE HW MOTOR ORANGE Pump overrun 7 8 9 10 1 2 3 4 5 6 7 8 9 10 N E PUMP S P E N BOIER EVOTOUCH CONTROER CS92A CYINDER THERMOSTAT N E PUMP E N BOIER 3
Application 2: Sundial Y plan system evotouch DHW Heating Junction Box V4073 Pump Radiators Boiler DHW Cylinder Sundial Y plan wiring plan NOTE: It is recommended that either the 10 way junction box or Sundial Wiring Centre should be used to ensure first time, fault free wiring. 230V 50Hz 3A RATED N E BUE G/YEOW HTG RECEIVER BDR91 N A B WHITE GREY DHW RECEIVER BDR91 C N A B ORANGE V4073A MID POSITION ZONE VAVE Pump overrun 1 2 3 4 5 6 7 8 9 10 7 8 9 10 E N N E PUMP S P E N BOIER EVOTOUCH CONTROER CS92A CYINDER THERMOSTAT N E PUMP BOIER 4
Application 3: Combi boiler evotouch ENGISH Radiators Pump Boiler Combi boiler wiring plan NOTE: 1. It is recommended that either the 10 way junction box or Sundial Wiring Centre should be used to ensure first time, fault free wiring. 230V 50Hz 3A RATED N E EVOTOUCH CONTROER RECEIVER BDR91 N A B 1 2 3 4 5 6 7 8 9 10 230V 50Hz 3A RATED N E EVOTOUCH CONTROER RECEIVER BDR91 N A B E N T1 T2 E N T1 T2 COMBINATION BOIER COMBINATION BOIER 5
Upgrade application 3: Combi boiler with domestic hot water The application Combi boiler can be upgraded to control domestic hot water as an S plan or Y plan system by installing the relay modules for both hot water and heating control and additionally the hot water sensor CS92A. However, the configured BDR91 boiler relay must be disconnected from the evotouch to be used as hot water relay or heating relay. The following steps must be done to upgrade the Combi boiler application into a S plan or Y plan application 1. Uninstall pre-configured BDR91 boiler relay Press the evotouch MENU button for approx. 10 seconds. 2. Configure S plan or Y plan system Press the evotouch MENU button for approx. 10 seconds. Go to menu EDIT SYSTEM CONFIG. Select HOT WATER DEMAND. Select option HOT WATER DEMAND. Bind the hot water sensor CS92A to evotouch. Bind the BDR91 hot water relay. Bind the BDR91 heating relay.... Go to menu EDIT SYSTEM CONFIG. Select BOIER DEMAND. Press the button NONE. Reset BDR91 boiler relay. Note: Press and hold the test button of the BDR91 boiler relay for 15 seconds until the red ED flashes 0.9s off / 0.1s on. This ensures that the configuration information held in the BDR91 boiler relay is removed. The BDR91 boiler relay is now uninstalled and can be configured as hot water relay or heating relay. 6
Safety notes Mounting CS92A Caution Isolate power supply and make safe before wiring the units to prevent electric shock and equipment damage. Installation should be carried out by a competent person. Mounting CS92A sensor The sensor should be mounted on the cylinder in a position between 1/4 and 1/3 of the way from the bottom. ENGISH EMC compliance considerations Keep AC mains supply/load cables separate from signal wiring. Refer to Code of Practice standards EN61000-5-1 and EN61000-5-2 for guidance. ocating CS92A and BDR91 units The CS92A transceiver and BDR91 relay module should be mounted in a location where there are no metal objects in a direct line between them and the evotouch. Do not mount on metal wall-boxes. eave at least 30cm distance from any metal objects and at least 1 metre from any other electrical equipment. For the CS92A transceiver select a preferred location, ensuring it is close enough to the cylinder so that the strap-on sensor element can reach the cylinder and test the signal strength before installation. Remove a section of insulation (1) and clean the exposed cylinder surface carefully to ensure good thermal contact. Position the sensor in the cutout. Cut fixing strap (2) to size (if required) to ensure sensor is held firmly against cylinder. 1 2 3 ocate mounting strap in the cover slot (3). Screw hooks into strap and link together. 7
Mounting CS92A transceiver The CS92A transceiver is supplied in the package with the mounting plate separated from the rest of the unit for ease of installation. The sensor wiring can be fed in from the top of the mounting plate or from the left hand side. Cut a suitable hole in the appropriate plastic breakout. Provide appropriate strain relief by attaching the sensor cable to the wall using cable clips, or alternatively run the cable in mini trunking. Powering up CS92A / Battery replacement First hold the transceiver approximately 1 metre from evotouch. To power it up, unclip the battery cover, remove the paper tab that isolates the batteries from their contacts, and replace the battery cover. When replacing batteries note the battery polarity. Closing CS92A transceiver Install the CS92A transceiver mounting plate in the chosen location next to the hot water cylinder. Wiring the CS92A transceiver Hinge the front piece of the CS92A transceiver onto the mounting plate and press until it clicks securely into place. ead the 2 sensor wires through the mounting plate and connect them to terminals A and B on the CS92A mounting plate as shown. The wires are polarity free, so they can be connected in any order. 8
Mounting BDR91 Mounting BDR91 = M3.5 = No6 ENGISH Open the BDR91 relay module by inserting a screwdriver in the opening at the bottom. The wiring can be led in either from the rear or from the left hand side. < 7mm > 7mm Install the BDR91 relay module mounting plate in the chosen location. Wiring the BDR91 relay module Connect the wires of the power supply and the boiler/valve control to the terminals on the BDR91 mounting plate according to the selected application (see application diagrams). Closing BDR91 relay module Hinge the front piece of the BDR91 relay module onto the mounting plate and press until it clicks securely into place. If entry from the left hand side is desired, cut suitable holes in the appropriate plastic breakouts. 9
Configuring CS92A How to bind CS92A to evotouch Hold the CS92A transceiver (without mounting plate and sensor) approximately 1 metre from evotouch. Green light (under button) Red light (under button) CS92A signal strength test Once CS92A is bound to evotouch, the signal strength test allows the transceiver to be positioned in the best possible location for signal reception. Activate signal strength test on the CS92A transceiver Green light (under button) Put CS92A into binding mode by pressing and holding the CS92A button for 5 seconds, until the green light comes on and the red light flashes once a second. Follow the evotouch GUIDED CONFIGURATION or EXPERT CONFIGURATION until the following screen appears. Red light (under button) Press the CS92A button once. The green light should come on. If it doesn t, reinsert the batteries and try again. With the green light on, the red light should start to flash to indicate the status. 5 secs Signal Strength = 5 Signal Strength = 2 Now press the CS92A button to send the binding message to evotouch. The evotouch display shows The BIND signal was received properly. Press NEXT when successful or BACK to send again.. If binding was successful CS92A will exit binding mode and both lights will switch off. If binding was unsuccessful, repeat binding procedure. evotouch measures the strength of the CS92A signal every 5 seconds and will communicate this to CS92A as a number between 0 and 5. CS92A will then indicate this number by flashing its red light a number of times in succession, followed by a pause of between 2 and 4 seconds. The number of flashes is equivalent to the signal strength number. A signal strength > 2 is recommended to ensure reliable communication. 10
Signal strength test step 1 Hold the CS92A transceiver (without mounting plate and sensor) approximately 1 metre from evotouch and check the signal strength is high (>2). If so, move to step 2. If the red light repeatedly flashes 0.1s on / 0.9s off without pausing, this means CS92A is not bound to evotouch. Go to How to bind CS92A to evotouch, follow the instructions there and after binding is complete, return to the signal strength test. Signal strength test step 2 Whilst staying in signal strength test mode, take the CS92A transceiver to the preferred location. Wait for 10 seconds and check the signal strength > 2. If so, the CS92A is ready to mount. If the signal strength is < 2, re-position the transceiver within the local area +/ 1m to see if the signal strength improves. If this fails, you may need to re-position the CS92A transceiver completely and extend the cable to the sensor element. Exit signal strength test Exit signal strength test by pressing the CS92A button again. CS92A will time out of this mode after 10 minutes, but may indicate a sensor fault if the sensor element is not connected within this time period. evotouch RF test The signal strength can be displayed at the evotouch, too. Go to the evotouch menu, select RF TEST HOT WATER and follow the instructions on the screens. Press the button of the CS92A briefly to activate the test mode. Press the NEXT button on the evotouch. The signal strength is indicated on the evotouch controller. The signal strength can be EXCEENT, GOOD, POOR or NOT RECEIVED. Error indications To save battery power, CS92A error conditions will be indicated on the evotouch. It is possible to view the CS92A status by pressing the button on the transceiver box. The lights underneath this button will provide feedback as shown in the table. Indication Green light on Red light flashes 0.1s on / 0.9s off Red light flashes 0.5s on / 0.5s off Red light on continuously Status Everything is OK, press button again to exit Battery low condition, replace batteries Sensor error, check sensor connection oss of communications ENGISH 11
Configuring BDR91 Binding BDR91 hot water/heating relay Note: Binding is terminated automatically after 5 minutes. After the power up of the BDR91 relay module the red ED will start to flash at 0.1s on / 0.9s off. If this is not the case, set the BDR91 into the reset mode (see instructions BDR91). Press and hold the button of the BDR91 relay module for 5 seconds to activate the bind mode. Checking RF communication The evotouch controller sends test signals to and from the assigned BDR91 relay module in order to test the signal strength. The red ED flashing at 0.5s on / 0.5s off confirms that the bind mode has been activated. Follow the evotouch GUIDED CONFIGURATION or EXPERT CONFIGURATION until the following screen appears. Position the evotouch controller as close as possible to the BDR91 relay module. Press the BIND button on the evotouch controller to send the bind signal to the BDR91 relay module. The red ED of the BDR91 is switched off to confirm a successful binding. The signal strength can be EXCEENT, GOOD, POOR or NOT RECEIVED. 12 The evotouch display shows The BIND signal was sent. Press NEXT when successful or BACK to send again. If binding was unsuccessful, repeat binding procedure.
Troubleshooting This section gives suggested answers to typical problems that installers may encounter: Problem Domestic hot water not available Solution In case of a communication failure the relay module for domestic hot water will be switched off. ENGISH Check RF communication. The batteries of the hot water sensor are discharged Check the hot water sensor: Press CS92A button and the red light blinks 0.5s on / 0.5s off. (Note: the light will switch off after approx. 1 minute to save battery power.) The evotouch will display a message that the batteries of the hot water sensor are discharged. It is important to change the CS92A batteries as soon as it is displayed on the evotouch. Reduced battery power might affect the RF signal strength and have an impact on RF communications. Communication loss Check battery status on the CS92A: Press CS92A button and the red light gives a short flash every second 0.1s on / 0.9s off. (Note: the light will switch off after approx. 1 minute to save battery power.) oss of communication will be indicated on the evotouch or the actuators. Check the RF communication between evotouch and the actuators and sensors. If there is no communication try to bind the device again. If this does not resolve the problem, check the RF path between the two devices and reposition any object that may be blocking the RF signal. 13
14 Safety information Approvals Conforms to protection requirements of the following directives: EMC: 2004/108/EC VD: 2006/95/EC R&TTE: 1999/05/EC EMC compliance considerations Refer to Code of Practice standards EN61000-5-1 and EN61000-5-2 for guidance. Caution: Isolate power supply and make safe before wiring the unit to prevent electric shock and equipment damage. Installation should be carried out by a competent person. ocation of device evotouch should be installed in an open space for best performance as it is a radio frequency device. eave at least 30cm distance from any metal objects including wall boxes and at least 1 metre from any other electrical equipment eg. radio, TV, PC etc. Do not mount onto metal wall boxes. For the best temperature control performance evotouch should not be placed near hot or cold sources (e.g. cooker, lamp, radiator, doorways, windows). Disclaimer This product and its associated documentation and packaging are protected by various intellectual property rights belonging to Honeywell Inc and its subsidiaries and existing under the laws of the UK and other countries. These intellectual and property rights may include patent applications, registered designs, unregistered designs, registered trade marks, unregistered trade marks and copyrights. Honeywell reserves the right to modify this document, product and functionality without notice. This document replaces any previously issued instructions and is only applicable to the product(s) described. This product has been designed for applications as described within this document. For use outside of the scope as described herein, refer to Honeywell for guidance. Honeywell cannot be held responsible for misapplication of the product(s) described within this document. PEASE RESPECT YOUR ENVIRONMENT! Take care to dispose of this product and any packaging or literature in an appropriate way. WEEE directive 2002/96/EC Waste Electrical and Electronic Equipment directive At the end of the product life dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product. Remove the batteries. Dispose of the batteries according to the local statutory requirements and not with the usual domestic refuse. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, ACS-ECC EMEA, Z.A. a Pièce 16, 1180 Rolle, Switzerland by its Authorised Representative Honeywell Inc. Honeywell Control Systems td. Arlington Business Park, Bracknell, Berkshire RG12 1EB Technical Help Desk: 08457 678999 www.honeywelluk.com
ENGISH 15
16 50055936-001 2010 Honeywell International Inc.