Surviving the Survivable Cable Crunch

Similar documents
Shut Down The Fan: A Reprise by Dean K. Wilson, P.E.

Fire Pump Supervision - Part 1 by Dean K. Wilson, P.E.

Fire Pump Supervision - Part 2 by Dean K. Wilson, P.E.

Not-So-Dead Air Space

Fire Pump Supervision - Part 3 by Dean K. Wilson, P.E.

Can You Hear Me Now?

Applying Performance-based Fire Alarm System Design Part 4

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

Article by: Ark Tsisserev, Principal, Stantec Consulting Ltd.

Can You Hear Me Now?

NFPA Changes

Performance-based Fire Alarm System Design Introduction

Fire Resistant Cables - Update Alan Cavers Engineering Manager Certificate Services Group

VITALink. FAQs I. GENERAL QUESTIONS

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

FIRE ALARM PRE-INSPECTION CHECKLIST 1. REFER TO CHAPTER 10 OF CURRENT STATE ADOPTED NFPA 72, FOR INSPECTION, TESTING AND MAINTENANCE PROCEDURES.

Get it Right the First Time Avoid These Commonly Cited Errors

SC # /16/17/18/19/23/24 D#03-24

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Changes in NFPA

Photovoltaic (Solar) Array Installation Guide

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

SECTION ELECTRICAL GENERAL PROVISIONS

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Town of Cicero Local Code Amendments

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

J-PRO TM Cable Support System

FIRE ALARM SYSTEMS & 780 CMR. Dave LeBlanc, PE, FSFPE March 17, 2015

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers.

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

ORDINANCE NO

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

MULTI-PHASED FIRE ALARM AND MASS NOTIFICATION SYSTEM UPGRADES: The Authority Having Jurisdiction (AHJ) and Proper Planning

REPORT ON DISCUSSIONS DURING UL MEETINGS WITH ELECTRICAL INSPECTORS AT THE 2003 IAEI 75 th JUBILEE MEETING

AIRPORT OFFICE BUILDING. Smoke Control System. Testing Procedures Manual. September 10, 2016

June 20, 2011 PARTIES INTERESTED IN FIXED CONDENSED AEROSOL FIRE-EXTINGUISHING SYSTEMS

Fire Prevention Coffee Break Training. May 2017

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

Are Open Bottom Electrical Handholes a NEC Violation? Proposals to Change the 2002 NEC Traffic Signal and Roadway Lighting Related

Bold items are particular to the City of Euless

Interpreting the National Electrical Code. By Tim Kuhlman, PE, RCDD

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Recent Revisions and Proposed Key Changes to Fire Code

Page 1 of 5 1/29/2016 4:08 PM. First Correlating Revision No. 3-NFPA [ Section No ] Submitter Information Verification

We have reviewed the proposed concept plans for Beehive Homes and have the following comments:

1.3 REFERENCE STANDARDS

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

Presented by: The Electrical Association of Philadelphia 527 Plymouth Road, Suite 408 Plymouth Meeting, PA (610)

Welcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

SECTION ELECTRIC-DRIVEN, FIRE PUMPS

Addendum # 2 Wicomico County Circuit Court Second Floor Renovations Date of Addendum: 2/6/2017

Welcome to the Keys to a Successful Fire / Life Safety Inspection and Sustained Tenant & Building Safety

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Overview of Process for Certification to NFPA Standards for Fire and Emergency Services PPE. IOM Workshop on Certification of PPT April, 13, 2010

Second Revision No. 601 NFPA [ Section No [Excluding

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

Western Michigan University Facilities Management Engineering Division

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Information Bulletin

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

Electrical Tech Note 107

UNIFIED FACILITIES GUIDE SPECIFICATIONS

MEMORANDUM. Subject: NFPA 1124 Proposed Tentative Interim Amendment (TIA) No. 1094

Slide 1. Slide 2 Instructor. Slide 3. NFPA 25 The Owner s Manual. Roles & Responsibilities DISCLAIMER

ANSI/NETA Standards Update

Koffel Associates, Inc.

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs

Life Safety Code Potpourri

SECTION ISOLATED POWER SYSTEMS

NEC 2017 Changes and Their Effect Upon the ICT Industry

NFPA 72 Code Changes vs 2013

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

American National Standard for Electrical Intermediate Metal Conduit

REQUIREMENTS. For FIRE DEPARTMENTS. State of West Virginia. Bob Wise Governor THE DEPARTMENT OF MILITARY AFFAIRS AND PUBLIC SAFETY

Hospital Fire Alarm Systems Recurring Misapplications and Misused Requirements

SECTION EXTERIOR LIGHTING

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

Questions/Comments for Richard Roux from Webinar on 7/11/13

NFPA Updates (c) 2015 SSR, Inc. All rights reserved Florida AHCA Conf

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

ST. LUCIE COUNTY FIRE DISTRICT FIRE PREVENTION CODE

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

Fire Code Action Committee (F-CAC) Meeting Minutes June 19-20, 2012 Chicago IL. Summary of Actions and Regional Work Group (RWG) Assignments

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS

Transcription:

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 1 Surviving the Survivable Cable Crunch by Dean K. Wilson, P.E. Question: I am a fire inspector in a mid-western city. We have recently received preliminary plans for four high rise apartment buildings. Naturally, in our jurisdiction, we expect the fire alarm systems for these buildings will meet all of the requirements of NFPA 72-2010, National Fire Alarm and Signaling Code or, when it is formally adopted in our state, NFPA 72-2013. We have heard from several sources that we will likely have a problem with the survivability of notification appliance circuits because contractors can no longer obtain the survivability rated cable. Can you enlighten me on this issue? Yes. This matter represents a significant challenge to designers, installers, and code officials alike. You see, on September 12, 2012, Underwriters Laboratories Inc. decided to remove the listing for all 2-hour rated cables and cable assemblies. This action has sent a shockwave of concern throughout the fire alarm industry. Routinely, fire alarm system installers have used these cables to meet the requirements for fire alarm systems installed to provide notification to occupants within high-rise buildings. Other applications include any occupancy where the fire alarm system must maintain operational integrity during the course of a fire event within that occupancy. And, installers of electric motor-driven fire pumps often use the larger amperage capacity versions of these cables to supply power to the fire pump s electric motor when the feeder circuit must pass through the protected building.

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 2 In the version of NFPA 72 that your jurisdiction continues to use, NFPA 72-2010, Chapter 12, specifically states the following requirements: 12.4 Pathway Survivability. All pathways shall comply with NFPA 70, National Electrical Code. 12.4.1 Pathway Survivability Level 0. Level 0 pathways shall not be required to have any provisions for pathway survivability. 12.4.2 Pathway Survivability Level 1. Pathway survivability Level I shall consist of pathways in buildings that are fully protected by an automatic sprinkler system in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, with any interconnecting conductors, cables, or other physical pathways installed in metal raceways. 12.4.3 Pathway Survivability Level 2. Pathway survivability Level 2 shall consist of one or more of the following: (1) 2-hour fire-rated circuit integrity (CI) cable (2) 2-hour fire-rated cable system [electrical circuit protective system(s)] (3) 2-hour fire-rated enclosure or protected area (4) 2-hour performance alternatives approved by the authority having jurisdiction 12.4.4 Pathway Survivability Level 3. Pathway survivability Level 3 shall consist of pathways in buildings that are fully protected by an automatic sprinkler system in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, and one or more of the following: (1) 2-hour fire rated circuit in tegrity (CI) cable (2) 2-hour fire rated cable system (electrical circuit protective system(s» (3) 2-hour fire rated enclosure or protected area (4) 2 hour performance alternatives approved by the authority having jurisdiction 12.5 Nomenclature. To identify the properties of the system(s) interconnections and survivability requirements, the following identification nomenclature shall be used: (1) System(s) interconnections (2) Survivability levels (not required if Level 0)

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 3 From all of the information I have seen thus far, it appears the initial cause for concern stems from a test conducted for a particular cable manufacturer who asked that UL test its cable with the cable installed within rigid metal conduit (RMC). The cable in the test failed. UL has made an initial determination that points to a chemical reaction whereby the zinc coating of the conduit combined with the copper of the cable under the heated pressure conditions inside the RMC during the fire test. Manufacturers of Rigid Metal Conduit commonly rely on this zinc coating as part of the corrosion resistant protection for the conduit. Reportedly, following this individual test failure and subsequent investigation into the cause, UL then ran additional tests on existing listed circuit integrity (CI) cable and discovered inconsistencies in performance, particularly with regard to the consistent performance of the cables during repeated fire tests. Based on these issues, all products and systems originally certified under UL 2196, Tests for Fire Resistive Cables, and ULC-S139, Standard Method of Fire Test for Evaluation of Integrity of Electrical Cables, will no longer receive the listing that had previously existed under the program formerly based on these standards. As a result, cable manufacturers are no longer authorized to place the UL mark or ULC mark on the following products: UL Classified Fire Resistive Cable (FHJR) ULC Listed Fire Resistant Cable (FHJRC) UL Listed cable with -CI suffix (Circuit Integrity)

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 4 Furthermore, UL has removed all Electrical Circuit Protective Systems (FHIT) constructed with Fire Resistive Cable from its certification directory. The National Electrical Manufacturers Association (NEMA) has responded to UL s action by issuing the following statement: Electrical Circuit Protective Systems are very specialized systems used in applications such as fire pumps, emergency systems, fire alarm and tunnels. It is the cable manufacturer that tests their cables with specific system components in order to achieve a fire-rating for that system. Typically, fire-resistive cable manufacturers have tested their cables in EMT and if their cables passed the test in EMT, they were allowed to be used in IMC or rigid steel conduit as well. It is important to note that this change was not due to any quality issue with conduit. One of the manufacturers of the fire-resistive cables was testing their cables inside of hot-dip galvanized rigid conduit and discovered a compatibility issue between the copper conductors and the zinc on the interior of the rigid steel conduit. Although the cable manufacturer reported an issue only with a conduit with a hot-dip galvanized interior, UL is taking a conservative stance and is requiring that components used in these systems have zinc-free interior coatings, while they conduct research on the issue. EMT and IMC manufactured by members of NEMA Section 5RN (Steel Conduit and EMT) are listed to UL 797 and UL 1242 respectively and do not have zinc interior coatings. The interior coatings are specialized organic coatings that provide a high degree of corrosion protection and easy wire-pulling.

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 5 In late September, the NFPA Technical Correlating Committee on Signaling Systems for the Protection of Life and Property (TCC) met with representatives of Underwriters Laboratories Inc. and learned that UL plans to rewrite the requirements for UL 2196 and ULC-S139 to make the required fire tests more consistently repeatable. In order to accomplish this rewrite, UL has reformed the Standards Technical Panel (STP) for these standards and has developed a work plan to begin the rewriting of the requirements. Because no data exists to prove that prior listed cables do not meet the requirements of these standards, UL has stated that the actions they have taken will not affect the listing of all existing cables already installed. Furthermore, any cables listed under these standards that have already shipped to distributors and job sites will remain listed and will maintain the appropriate designation under the requirements of UL 2196. The NFPA Technical Correlating Committee on Signaling Systems for the Protection of Life and Property (TCC) has decided to wait for UL to conclude its planned actions before taking any specific actions of their own regarding revisions to either Chapters 12 or 24 of NFPA 72-2013, National Fire Alarm and Signaling Code. However, IMSA members should particularly note that NFPA 72-2013, Chapter 27 Public Emergency Alarm Reporting Systems now requires installers to use Type CI cable for public communications cables and furthermore requires that installers place these Type CI cables in RMC. Because UL s investigation has proven that this installation method will compromise the function of the Type CI cable, the NFPA Technical Committee on Public Fire Reporting Systems and the NFPA TCC will promptly process a Tentative Interim Amendment (TIA) to revise or remove the requirement from Chapter 27 of NFPA 72-2013.

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 6 Whether you work with fire alarm systems as a designer, installer, or code official, you will need to stay on top of this matter as it develops in the months ahead. I will attempt to bring any significant changes to your attention through this bi-monthly column. IMSA member Dean K. Wilson, P.E., FSFPE, C.F.P.S., now retired on disability, formerly worked as a Senior Engineer in the Erie (PA) office of the fire protection engineering and code consulting firm, Hughes Associates, Inc. (www.haifire.com.). The opinions expressed in this article are strictly his own. You may reach him by e-mail at deanwilson@roadrunner.com or by telephone at 814-397-5558.