AQUAVOLTA MOSES 7. Alkaline Water Ionizer SM-V112TL USER MANUAL. presents. Use acidic water that is:

Similar documents
JP-103 ALKALINE WATER IONIZER

Emco Tech Neptune Water Ionizer

CONGRATULATIONS ON YOUR NEW PURCHASE! TABLE OF CONTENTS

ULTRA DELPHI ALKALINE ANTIOXIDANT WATER

HWP-55(EN) Instruction Manual. Alkaline ionized water apparatus

VESTA ALKALINE WATER IONIZER OPERATION MANUAL

USER MANUAL NON-ELECTRIC MINERAL WATER PURIFIER. The Industry Leader in Alkaline Water Ionizer Technology NON-ELECTRIC MINERAL WATER PURIFIER

phd Countertop UltraWater Owner s Manual Delicious Great Tasting Antioxidant Alkaline Energized

Athena H Alkaline Water Ionizer and Hydrogen Generator Only from AlkaViva

Contents. Product Description. Features. Quick Guide. Touch Panel Operation. Instruction. How to change the filter. Warning.

Series Vesta H2, Athena H2, Melody II

Contents. Product Description. Features. Quick Guide. Touch Panel Operation. Instruction. How to change the filter. Warning.

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

ROX-10WB-E WATER ELECTROLYZER INSTRUCTION MANUAL FOR END USER L188AU111 (100507)

A few simple steps to ensure perfect water, every time.

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Basic Information Of Water Ionizer

Delphi H 2 Owner s Manual

VAVIE ALKALINE WATER DISPENSER USER MANUAL

AquaReef Cube. Inspiring Excellence in Fish Keeping!

HOT & COLD WATER PURIFIER CLIMA MESA / PISO

AQVA ULTRA Faucet Purifier AQ003-1 User s Guide

Installation & Operating Guide

A few simple steps to ensure perfect water, every time.

Installation & Operating Guide

Electrical Mini Tank Water Heater anual, and Warranty nformation

Tap Master Artesian Hydro Gardener Series Installation & Service Manual

A few simple steps to ensure perfect water, every time.

WCD-200W Water Dispenser

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

EcoMaster - Residential Pools up to 40,000 Gallons

- 1 - Updated on 18 March, 2010

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

Table of Contents. English

TUB AND SHOWER FAUCET

instructions 10,000 prize draw PLUS Free Rewards Gallery Register online now to collect your reward See back for details

FagronLab NP-1 UV. Negative pressure workbench. User Manual

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Model CWA200 Owner s Manual

USER MANUAL 03-0_MOD-KH1203US_H5_H5.indb _MOD-KH1203US_H5_H5.indb /11/08 21:28: /11/08 21:28:13

ULTIMATE REVERSE OSMOSIS SYSTEM

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Bar Fridge USER MANUAL MB46W

Local air conditioner

Water Filter. cover. start button. reminder of cartridge replacement. remainder of life of a cartridge it is time to replace a cartridge

6. COOLING SYSTEM 6-0 COOLING SYSTEM MXU 500

Whole House Descaler Installation Instructions

Air Purifier. Purificateur d airs. Purificador de aire

WCD-210BK. Water Dispenser OWNERS MANUAL. Read and save these instructions.

SLT-Series Installation and maintenance instructions

85 Series USER MANUAL

Requests for Daily Care and Maintenance

English. Your Model Number is: HD1500 IMPORTANT

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

Glass and Dishwashers AMX / AUX Series

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien

K Specifications. Max. Water Volume

Ozone Generator Systems

K Specifications. Max. Water Volume

Combination ultrasonic and heating method of misting. Micro-computer automatically senses air humidity and start operation

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

Water Distillation System Instruction Manual Nutriteam TC-501

Intelligent Super Toilet AFC230 User Instruction Manual

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY:

Ultrasonic Aroma Diffuser AD-SD1-CE

Table of Contents. List of Figures

PZ1, PZ3 & PZ6 Installation Guide

Requests for Daily Care and Maintenance

1 P a g e. G4 Counter Top OPERATION MANUAL

Owners Manual. 900 Series Drinking Water Appliance

EXC-450 User s Manual

FAR INFRARED RAYS HEATER

TABLE OF CONTENTS FOR YOUR SAFETY

Installation & Operating Instructions

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use.

Instruction Sheet DANGER

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

USER MANUAL Model DWP-55/DWP-66

83 Series USER MANUAL Thank you for purchasing E LOO electronic bidet.

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

100 Series Maxi Internal Filters

Glass and Dishwashers AMX / AUX Series

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

User s Manual The Warranty is attached to this User s Manual

Requests for Care and Maintenance

Rules for Safe Operation

Food Waste Disposer Instruction Manual

Installation & Operating Instructions

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

TRIO Rx. Portable Ultra- High FAC Decanter Activator Set Instruction Manual

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

VADA - Rain2Main Automatic Rainwater Controller

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

BIOZONE ICEZONE OWNER'S MANUAL Single Horizontal Evaporator Style Ice Machines BioZone Scientific International

USER MANUAL WATER DISPENSER WITH ICE MAKER

UV Lamp and Quartz Sleeve Replacement/Maintenance

Transcription:

WWW.AQUACENTRUM.DE USER MANUAL presents AQUAVOLTA MOSES 7 Alkaline Water Ionizer SM-V112TL Use acidic water that is: A fantastic astringent for skin care A good antiseptic Great for cleansing Warning: Incorrect installation and/or operation could void your valuable warranty. Please protect your investment! READ THIS MANUAL CAREFULLY

Safety Precautions If the product is immersed in water by accident, remove the plug from the socket and remove the product from water. Contact the Service Center. It may cause electric shock. Do not use power outside the power rating of the socket or device. In any case power other than 220V MUST NOT be used. Do not use the product with other electric devices at the same time as it may cause fire. Do not disassemble, repair or alter the product. It may cause fire or electric shock. Please contact the retailer or the Service Center for repair. Do not splash water to the product. Do not wash the product with water. It may cause short, electric shock or breakdown. Do not pull on the power cord. Do not touch the plug with wet hand. It may cause electric shock. Excessive dust on the plug may cause moistening leading to poor insulation or fire. Remove the plug from the socket and wipe off with dry cloth. Push in the plug all the way to the socket. Loose connection may cause electric shock or heat generation leading to fire. Do not use a defective plug or loose socket. Do not bend the power cord by force. Do not damage or deform the cord by placing a heavy object over it. (It may cause fire or electric shock.) Wipe off dust or water from the pug pins and the connection parts. (It may cause fire or electric shock.) Do not block the Water Output. Do not bend, twist or press the hose. It may cause water leak, incorrect ph level in water or product malfunction. Remove the plug from the socket immediately if there is abnormal noise or smell from the product, and contact the Service Center. It may cause fire or electric shock. Do not install the product in an area exposed to freezing or direct fire. Ambient temperature : 10~40oC, Water temperature: 5~30oC Install away from excessive humidity or dust, water splashes or direct sunlight. It may cause fire or electric shock. Do not use water other than drinking water. Do not place the ph measuring solution near fire. It may ignite leading to fire. This product should not be installed in a location where it may be subject to freezing temperatures. Connect the product to the cold water pipe. Connection to the hot water pipe may damage the filter or electrolyzer. Hot Water Do not install the acidic water hose higher than the product; Keep the length below 1.5m, and do not immerse the hose in water. It may cause insufficient water flow or poor water discharge. Before using the product that had not been in use for a long period of time, let water flow for 2-3 minutes to ensure proper operation of the product. Do not use aluminum containers that are vulnerable to alkaline, or copper containers that are vulnerable to acid. Metal containers may cause corrosion or weaken the activation condition. The ph measuring solution must not be swallowed, put in eyes or applied to the human body. If swallowed by accident, drink plenty of water to induce vomiting. If got in the eyes, wash off with plenty of water. Contact the physician immediately. If splashed onto the human body, wash off with plenty of water. Keep the solution capped and away from the reach of children. 02

MELODY Name and action of each part Front side Displaying part and operating part Display Display which indicates operational status when device is activated. Function selecting button Button which is used when each function is selected. Alkaline water discharging nozzle Passage through which alkaline water comes Water supplying valve which supplies/blocks raw water to main body Filter 3888 Alkaline 2 ph 9.0 Running Time 00:00:14 Flow 1.6 Displaying filter lifespan Indicating total amount of filter use Displaying water discharging time Indicating time during which water is discharged Displaying number of grade in use Indicating number of grade in alkali/acid and purification currently in use Displaying ph Indicating ph for each grade Displaying quantity of supplied water Indicating total water flow per minute Back side Calcium Cap To add calcium Power Switch To supply or block power to the product Accessories Fuse Holder A safety device against over-load Volume Control Switch To adjust voice volume Water Input The passage of water entering to the product Acidic Water Output The passage of acidic water discharged from the product A/C Power Cord A cord for power connection MELODY Setting display Method to use lamp which is on when each function is selected Alkali selection button Button which is used when function of alkaline water is selected Water purification button Button which is used when function of water purification is selected Acid selection button Button which is used when function of acidic water is selected Filter Identify button Button which is used to check filter status Melody button (muting melody sound) Function that can make melody sound on/off which is made when each function is selected ph test kit Spare adaptor Inlet White Hose Outlet Gray Hose Color chart Manual Setting button Button which sets each function 03 04

How to use Initial operation When drinking alkaline water 4th grade of alkaline water is recommended for special use. Turn on power switch on back side after plugging power cord into socket. ON Supply raw water inside by turning on water supplying valve under stand-by mode. OFF Signal sounds, initial screen appears and disappear again, which makes it stand-by status. When pressing alkaline water selection 02 button, graphic lamp is on which indicates character of alkaline water, number of grade, and announcement can be heard which informs alkaline water grade. Whenever you press alkaline water selection button repeatedly, it changes number of grade. Filter 3888 Alkaline2 ph 9.0 Running Time 00:00:14 Flow 1.6 1 2 3 4 1 2 3 4 02 When supplying water by turning on water supplying valve, voice announcement can be heard according to previous mode, and counting lifespan of filter starts er 3888 Filter ph 9.0 Running Time 00:00:14 Alkaline 2 Flow 1.6 How to stop If turning water supplying valve to OFF position, water supply is stopped and it is converted to stand-by status automatically. Reference If alkaline water function is set previously, alkaline water used in previous step is discharged without additional operation when you turn water supplying valve to ON position. 05 06

How to use When using acidic water This function is necessary when getting a lot of acidic water and using it for washing face or body. Supply raw water inside by turning water supplying valve to ON position under Stand-By mode. When drinking purified water Supply raw water inside by turning water supplying valve to ON position under stand-by mode. When pressing acidic water selection 02 button, graphic lamp is on which indicates character of acidic water, number of grade, and announcement can be heard which informs acidic water grade. Filter 3888 Acidic2 c2 ph 5.8 Running Time 00:00:14 Flow 1.6 If pressing purified water selection 02 button, graphic lamp of purified water character is on, and announcement can be heard saying that this is purified water and purified water is discharged. Filter 3888 Filtered ph 7.0 Running Time 00:00:14 Flow 1.6 Whenever you press acidic water selection button repeatedly, it changes number of grade. 1 2 3 4 1 2 3 4 How to stop If turning water supplying valve to OFF position, water supply is stopped and it is converted to Stand-by status automatically. Acidic water is not drinking water. Be careful not to drink acidic water, confusing it with alkaline water. How to stop If turning water supplying valve to OFF position, water supply is stopped and it is converted to Stand-by status automatically. Reference If alkaline water function is set previously, alkaline water used in previous step is discharged without additional operation when you turn water supplying valve to ON position. Reference When turning on water supplying valve under stand-by release status, purified water is discharged. (However, voice is not heard and graphic does not flicker.) 07 08

How to use Volume adjusting function for voice information Press melody button for 3 to 5 seconds under stand-by mode. Adjust volume by alkali and acid button. Volume consists of 0 to 10 steps. Time and date adjusting function After entering time setting mode screen by pressing setting button among stand-by mode, select year, month, date, hour and minute by setting button and adjust them by alkali button and acid button respectively. 10 Time Setting Year 23 SAVE : MELODY EXIT : FILTER UP : ALKALINE DN : ACIDIC NEXT : MODE SAVE : MELODY EXIT : FILTER UP : ALKALINE DN : ACIDIC 02 If saving volume by pressing melody button, it is converted to stand-by screen. If there is no additional operation after completing volume adjustment, it is saved and converted to stand-by status automatically after 10 seconds. When saving it by pressing melody button, it is converted to stand-by screen 02 automatically. If there is no additional operation after completing volume adjustment, it is saved and converted to stand-by status automatically after 10 seconds. Stand-by screen adjusting function After entering setting mode screen by pressing setting button among stand-by mode, set ON/OFF function for stand-by screen by pressing alkali button. Function that checks filter capacity and amount of its use If pressing filter button among stand-by mode, you can check filter capacity and its remaining capacity. Time Setting Time ON/OFF ON NEXT : MODE SAVE : MELODY EXIT : FILTER UP : ALKALINE DN : ACIDIC Filter View Filter : 4000l Filter remaining : 3777l EXIT : FILTER or MELODY 09 10

Change of genuine filter Caution If you do not use genuine filter and use similar product instead, electrolysis function is not activated, only purified water is discharged and problem may occur at the time of electrolysis because dust and grain generated from activated carbon is flowed into electrolytic cell. Use genuine filter definitely. If there arise some problems, free after service is not available. (Period for free after service: 1 year) 05 Turn on power switch on back side of product. 06 Check water leakage after making water flow for 2 to 3 minutes by opening water supplying valve with power off. ON OFF How to change filter When lifespan of filter comes to an 02 end, graphic figure of filter indicates 0000 and filter change icon flickers, which is informing that it s time to change filter. Filter 0000 Stop supplying water by turning power switch on back side of product to OFF position. ON OFF Filter Reset Press and hold the filter button for 3 seconds. Filter reset function This is the function that initializes filter by MiCOM, of which lifespan comes to an end. Press and hold the alkaline button 02 for 3 seconds. 03 After having projected part of genuine filter face toward front, equip it in line with bottom groove and push it inside. Equip filter by turning projected 04 part of filter until it can not be turned any more in one direction. 3 seconds 3 seconds Filter Reset Filter : 4000l Filter remaining : 0000l RESET : ALKALINE EXIT : FILTER or MELODY Filter Reset Filter : 4000l Filter remaining : 4000l RESET : ALKALINE EXIT : FILTER or MELODY Reference If filter is new, initial water can be black and turbid. It is not harmful to health because it is activated dust which is spilled from inside of filter. 11 12

Composition of filter/ How to measure ph Composition of filter How to measure ph Fiber Filter Silver Activated Carbon Important Note: Water quality and mineral contant vary greatly in different Iocalities and will directly impact performance of your ionizer with respect to ph. Fill one of the test tubes provided about 1/4 full with alkaline, acidic or purified water. Fiber Filter Calcium ALKALINE WATER PURIFIED WATER ACIDIC WATER Fiber Filter Activated Carbon Fiber Filter Calcium Fiber Filter Tourmaline 02 Drop2 or 3 drops of the ph reagent into the container and shake it. If the reagent and water are not mixed well, the correct result may not be and shake it. Mesh Gauze Caution It is better to use UF(Combined hollow fiber membrane) filter initially, with power off, after making water of 20 l(1 kg / cm2 ) flow for approx. 5 minutes at minimum without fail, in order to eliminate hydrophilic substance. (If water pressure is below 1kg/cm2, a time longer than 5 minutes is needed) Recommended period for changing filter Effective period of use of filter may differ greatly depending on season and usage environment (quality and pressure of water and amount of use) 03 The ph value is determined by matching the color the ph color chart provided. Reference Change filter when follow phenomena occur even filter change icon does not flicker. When water flows little because filter is blocked due to heavily contaminated water When water smells because seriously contaminated water is flowed in When lots of foreign substance in water (turbid water, invisible substance) is eliminated in a short time When reusing it after you do not use it for a long time DO NOT consume water containing reagent Keep the ph reagent Iiquid, color chart, and OPEN FLES! For contact with eyes, flush Iiberally with fresh water, seek medical help If ingested, induce vomiting, seek medical help. 13 14

How to Install Source water Warning! Keep order of Dust pre-filter and Constant flow valve when machine is installed Dust Pre- Filter Inlet Acidic water outlet 4. ATTACH THE TAP WATER INLET HOSE TO YOUR IONIZER Attach the free end of the four inch length of white hose with the pre-filter attached to the gray port on the bottom of the ionizer. To attach the white inlet hose, by pushing it firmly into the grey tap water inlet port. (To remove it, press on the end of the fitting and pull it out at the same time). Inlet hose (PE hose) Inlet Fitting(1/4 ) 5. POSITION YOUR IONIZER This can be beside the sink, to the rear of the sink, or on the wall above the sink (there are keyhole slots on the back for this). Make sure it is on a hard and level surface Installation method Your gives you the option of three installation methods: 1) at your sink attached to your faucet with a diverter, 2) at your sink but plumbed directly to your cold water line (no diverter) and, 3) undersink - completely out of sight with a small dedicated faucet. It is recommended that methods 2) & 3) be done by a plumber. Installation Method 1) At the sink with a diverter (easiest) 1. ATTACH DIVERTER TO YOUR TAP Remove the aerator from tap (pliers may be required), and attach diverter valve in its place. There are adapters supplied in case the diverter does not fit your tap. If you have leaks at the diverter, use plumber's Teflon tape (available at any hardware store for a couple of dollars). 2. CUT A FOUR INCH LENGTH OF WHITE HOSE Using a very sharp utility knife, cleanly cut a four inch length of the white hose. The cleaner you make your cut, the less likely you will experience a leak. 3. ATTACH THE IN-LINE PRE-FILTER There is a small black arrow on the pre-filter indicating water flow direction. The arrow on the pre-filter will POINT AT YOU IONIZER indicating water flowing toward the ionizer. Insert the four inch length you cut into the end of the pre-filter making by pushing firmly ensuring the arrow is pointing at the end of the four inch hose. The four inch length will be between your ionizer and the pre-filter. PRE-FILTER 4 HOSE INLET 6. ATTACH THE TAP WATER INLET HOSE TO THE DIVERTER a. Insert the long length of white hose into the free end of the pre-filter (see photo). b. Remove the small compression nut on the back side of the diverter opposite of the diverter lever. c. Slide this nut over the end of the white hose with the threads positioned so you can screw it back onto the diverter. d. Push the white hose firmly onto the nipple, and then screw the compression nut back onto the nipple. Make sure the nut is screwed firmly in place, but do not over tighten. If you are having trouble getting hose on to the nipple, try soaking it in hot water for a minute. 7. ATTACH THE GRAY ACIDIC OUTLET HOSE. The ACIDIC OUTLET port is on the lower right corner of the back of the ionizer, and is labeled with a red sticker. First slide, one of the small squeeze clamps over the end of the hose. To make it easier to attach, soak the hose in a cup of warm water for 20-30 seconds. Firmly push the hose all the way onto the gray outlet port. Squeeze the clamp and slide it over the port. Ensure the opposite end runs down into the sink. Cut the hose to a convenient length. 8. CONNECT THE POWER CORD to an appropriate power outlet. 9. INSTALL FLEXIBLE STAINLESS STEEL SPOUT Screw this into the port on the top of the ionizer. Do not over tighten. 15 16

Trouble Shooting Guide The product may not operate by improper use or trivial causes, rather than by break-down. Before contacting the Service Center for repair, please refer to the following: Symptom Check point Troubleshooting For symptoms other than those listed in this table, please turn power off the product, and contact the Service Center. Symptom Check point Troubleshooting There is no display in the stand-by mode. Unregistered filter shown on the display Even with the supply of raw water, there is no display. 1. Is the power cord properly connected? 2. Is the power switch turned ON? 3. Is the fuse broken? 4. Is the fuse holder properly coupled? 1. Did you replace the filter with an authentic filter? 2. Did you register an authentic filter? 3. Are you using a non-authentic filter? 1. Did you replace the filter with an authentic filter? 2. Did you register an authentic filter? 3. Are you using a non-authentic filter? 1. Connect the power cord properly. 2. Turn on the power switch. 3. Replace the fuse. (250V/2A) 4. Couple the fuse holder properly. Replace with an authentic filter, and register it. Replace with an authentic filter, and register it. Water tastes bad. During the ph measuring test with the ph measuring solution, acidic water turns yellow but alkaline water changes to neutral. 1. Is the filter beyond the replacement cycle? 2. Electrolyzed reduced water is highly active. although it is suitable as drinking water, a trace of cl2 may remain in the water leading to bad smell? 3. Over-electrolysis due to insufficient amount of input water may cause bad smell? 4. Is the hose for input water bent? Carbonic acid in water is momentarily turned to neutral due to chemical reaction. 1. Replace the filter. 2. Adjust the ph level. If the problem persists, replace the filter. 3. Fit a booster pump to increase the amount of input water. 4. Unbend. This is harmless to the human body. The sight of it may be unpleasant, but it is safe to drink. Increase the amount of input water, or lower the ph level. Registration disabled appeared on the display. Have you attempted to register the filter more than 9 times? Replace with an authentic filter, and register it. Bottled ionized water has foggy substances settled on the bottom. Excessive carbonic acid (CO3) in water bonds with calcium producing calcium carbonate (CaCo3). Increase the ph level. Little or no water dispensed Power suddenly turns OFF during operation The filter replacement lamp flickers. 1. Is the supply of raw water sufficient? 2. Is the filter blocked? 3. Is the Input Hose bent? 4. Is the flow control on the faucet diverter locked? 1. Is the fuse broken? 2. Have you used the product for a long period of time at once? Is the filter beyond the replacement cycle? 1. Check if there is water cut. Check if the raw water valve is open, or the hose is bent. 2. Replace the filter. 3. Straighten the bent hose. 4. Open the flow control device and adjust the flow rate. 1. Replace the fuse. (250V/2A) 2. The product will stop to protect itself from over-current. Wait for 5 minutes to recommence. Replace the filter. No smell at first, but water smells after an hour of storage. Water leaking around the filter or somewhere inside the product. No water dispensed from the Acidic Output. 1. Is the container contaminated? 2. Do you live in the area where water contains a lot of salt? 1. Is the filter properly fitted in? 2. Is the leakage from somewhere other than the filter? 1. Is Water Output blocked? 2. Is the Water Output Hose bent? 1. Use a glass container with a cap, and wash it often to keep clean. 2. The level of permittivity may vary from place to place due to varying degree of excessive electric charge. Lower the ph level. 1. Remove the filter, check the O-ring and put the filter back. 2. Stop immediately and contact the Service Center. 1. The output line should be positioned lower than the Water Output of the product. 2. Unbend. 17 18

Some uses for Alkaline and Acidic WATER Product Specifications Some uses for the different levels of Alkaline Water Alkaline water levels Note: ph levels will always vary with different source water. Level 1 Level 3 Weak Alkaline water (ph7.5 - ph8.6). This level is used for initial consumption period (4-7 days). Let your body adjust slowly to this increase in ph. Medium to Strong Alkaline water (ph8.5 - ph9.7). This is the most common level of alkalinity for drinking purposes. Some people may start to detect a strong change in taste. Level 2 Level 4 Weak to Medium Alkaline water (ph8 - ph9.3). Move up to this level after the initial adjustment period. Adjust to this level for 3-4 days. Most people will drink at level 2 or 3. Strong Alkaline water (ph9.5 - ph10.5). Generally, most people find this very strong tasting and with powerful detoxifying effects. Product Specification Production Permit No. No. 610 by KFDA Item Approval No. Heo12-1692 Product Name Alkaline ionized water Model SM-V112TL Input (Consumption) Power 230VA Weight Approx 4.5kg Dimensions (W*D*H) 270 * 135 * 383mm Operable Water Pressure 0.7 5kgf/cm 2 Operational Water Temp 5-30 Some uses for the different levels of Acidic Water Descriptions of Acidic water levels Note: ph levels will vary with different source water. Control Method Operation Method Electrolysis Method All-in-one Input Water Valve ON/OFF Method Opening and shutting Tap Water Continuous type Level 1 Level 3 Weak Acidic water (ph6.5 - ph5.5). Used for oral hygiene, mouth wash etc. Medium to Strong Acidic water (ph5.5 - ph5). For cleaning in the kitchen. Level 2 Level 4 Weak to Medium Acidic water (ph6.0 - ph5.5). For skin care, as an astringent. Strong Acidic water (ph5.0 and lower). For sterilization purposes. Electrolyzer Levels of electrolysis concentration Volume of ionized water Cleaning Method Electrolysis Pole material 1 4 levels Fully automatic through the automatic channel conversion(darc) Platinum and titanium(surface area1.213 cm2 ) Filter Replacement What would I use the Filtered Water for? Purifier Filter Life Filter Usage Filter Structure The ph of Filtered water is neither raised nor lowered and would be the same as your tap water. This water is simply cleaned of impurities by the advanced filtration system. You can use it both as drinking water and to take medications with. Thermal Cut-out Device Water Supply Protection type and class against electric shock: Class II device, Type B applied part 19 20

Some uses for Alkaline and Acidic WATER Memo WARRANTY CARD memo 1.Warranty Detail This product passed the precise inspection under strict quality control. In case the product is found to have any defect in production or to get any spontaneous mechanical malfunction within the warranty term, return the unit to our sales agency, distributor or our service center along with this warranty card for repair free of charge. 2.Warranty term 12 months from a purchasing date. 3.Exception to warranty Expiration of warranty terms. Defect caused by a natural disaster. Damage or malfunction resulting from misuse. Model Purchasing date Warranty term SM-V112TL ( )th Day, ( )Month, ( )Year Till( )th Day, ( )Month, ( )Year Purchaser name Address Distributor Name Address Fill in this warranty card upon receipt of new unit. Receipt can be in force as warranty card. 21 22