Security Systems Price list 2008 DORMA. Pre-version with new prices. Click here:

Similar documents
Free swing slide-channel door closer TS 99 DORMA. in Contur Design

Panic Hardware PHA 2500 DORMA PHA 2500, GB

Panic Hardware PHA 2500 DORMA PHA 2500, GB

The Plus for the door. PORTEO. Opening and closing made easy.

Technical Documentation PORTEO. reddot design award winner geprüfte Sicherheit. achieved for: Ease of Use.

Beckhoff short profile

Hold-open magnets DORMA

Swing Door Operator DORMA CD 400

PHA 2000 PHB 3000 EXIT PAD

Installation Instructions

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Hold-open device Hold-open system DORMA TS73EMR TS73EMF

STT 3000 Series STT250 /150 Surge Protection Device Specifications

ES 75. Sliding door operator

Concealed cam-action door closer system DORMA ITS 96

Premium freezers combining functionality, elegance and energy efficiency

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

CRA24-B3 controlled residential ventilation

ES 200 Easy. Sliding door operator

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Universal operator - easy to install, reliable in operation

BST/FBST COMFORT LINE. Curved Sliding Doors

Advantages of automatic boiler bottom blowdown

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

ES 200. Sliding door operator

International standards used locally worldwide ISO/TC 67

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

Accuracy counts! Sensors with analog output

KNX The worldwide STANDARD for home and building control. KNX Association International

Textile fire protection closures EI 30/90

Certificate of constancy of performance,

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK


ES 200 T Easy ES 200 T ES 200 T-2D

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

The advantages of closed heating systems. White paper

PTG, SWT Series. Heat Recovery Systems

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

Expansion vessel in a solar installation. White paper

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

STANDARD T6 (200 C) SENSOR CABLE RANGE

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

For more information on Tarkett go to

AutoM Click to go to the page. AutoM Auto Shaker Filter

TS 99 EN 2-5. Free-swing slide channel door closer in Contur design

L-force Drive-based Safety. Safe, scaleable and above all integrated

KNX The worldwide STANDARD for home and building control. KNX Association International

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

GEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM

TMS. Door Management System

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at ore.hu.

Compact FREME. flash recovery energy management equipment HEAT TRANSFER SOLUTIONS

Fire-Resistant. Automatic Doors

DESCRIPTION FEATURES WARNINGS APPLICATIONS

Integral X-LINE. Security without boundaries. FIRE ALARM.

Labeling and Identification Products

Return loss measurement of fiber optic components

Future development of the furniture industry A look at the next 3-5 years

GEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM

A whole world of technical excellence

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

MKN Galley Solutions

EU directives WEEE and RoHS. Information and notes

SecurWATCH IP. The safety net for disoriented persons with intelligent additional functions HEALTH CARE

Large variety small footprint

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Heinz Lux. Director, KNX

Value engineering developed from global experience

AERO 20 AERO ENGLISH - Operating Instructions

COOL 1. Service manual

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut

PHA Panic Hardware for timber doors

OneWireless Gauge Reader WGR400 Series Specifications 34-XY July 2009

FieldLink Cable solutions for Automation & Drives

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Signal converters SVE4 Product overview

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Telematics Services. Vodafone Power to you. Vehicle Security and Remote Management in the palm of your hand. automotive.vodafone.

Rotary Blowers COMPACT Series With the world-renowned OMEGA PROFILE Air delivery 0.5 to 93 m 3 /min Pressure up to 1000 mbar, Vacuum to 500 mbar

Battery Industry EFFICIENT APPLICATIONS SOLUTIONS

This document is a preview generated by EVS

Rotary Screw Compressors SXC»Compact«Series

Multidecks TectoDeck MD4 Leho TectoDeck RI4 Leho. Energy efficiency with a system

TS 93. Cam action door closer system in Contur Design

StolenVehicle Tracking

Hexagon regular nuts (style 1) - Product grades A and B (ISO 4032:2012)

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Pressing for Excellence. Tunnel Finisher & Bagging Machines

COMPLETE MEDICAL GAS SUPPLY SYSTEMS

BUILD the clinic you ve always imagined.

A2, A6 PEK Control Unit

List of nationally authorised medicinal products

maxsys TRIO/DUO BOILER SYSTEM

Air and dirt in closed systems

English Version. Daylight of buildings

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

Transcription:

DORMA Security Systems Price list 2008 Pre-version with new prices Click here:

Informations for using this pdf-file: Click a line in the list of contents and you will be led to the respective site. CODIC Access Control Systems and switching accessories CODIC MasterCARD system overview 82 CODIC MasterCARD CMC-Hxx, IOM-CO1, PSU-xx 83 Order form XS-Zylinder 84 85 XS cylinder reader module, accessories 86 90 CODIC-CARD system overview 91 92 CODIC-CARD components 93 99 XS anti-tamper fitting, offline model 100 IBL interior door fittings, accessories, wall models, control units 101 104 CODIC software 105 CODIC BT and CODIC BTL security door fittings and accessories 106 CODIC CC-, CI-key and accessories 107 Click the headline for your way back to the list of contents. XS Cylinder Reader module Click here:

DORMA Security Systems Page 2 in the list of contens Price List 2008 Information Your partners in Europe and Worldwide 2 3 General information, list of symbols, direction of door opening and safety information 4 5 Emergency Exit Systems Emergency exit control Example systems 6 11 Individual application solutions 12 15 TL door terminals and accessories 16 19 TL door terminals, Swiss model 20, 32 NT power supply units 21 TV electronic exit bolt / keep and accessories 22 23 SAA control, monitoring and alarm equipment 24 27 TMS system overview 28 29 TMS door management system and accessories 30 40 System 55 trims 41 42 SVP Emergency Escape Lock with Automatic Locking Action Example systems with SVP 6000, SVP 2000 43 44 SVZ 6000, SVP 6000 fail-secure model and fail-safe model 45 54 SVP 5000 / SVP 4000 / SVP 2000 55 60 SVP-S motor lock controls 61 62 Accessories SVP, KÜ, KS, TK 63 Example system M-SVP 2000 64 Multi-point locking system M-SVP 2000 65 66 EST, ESS intruder detection systems 67 HZ inactive leaf locking device 68 70 SVP-SB security door fittings 71 ZM Expansion modules 72 Electric strike and accessories Series Basic, Basic-Safe 73 Series Basic-R 74 Series Basic R-Safe, Basic-Small 75 Series Fire 442, Fire 441, Fire 447, 117 RS 76 Serie Smoke 77 Accessories 78 80 Technical Data 81

DORMA Security Systems Page 1 in the list of contens Price List 2008 CODIC Access Control Systems and switching accessories CODIC MasterCARD system overview 82 CODIC MasterCARD CMC-Hxx, IOM-CO1, PSU-xx 83 Order form XS-Zylinder 84 85 XS cylinder reader module, accessories 86 90 CODIC-CARD system overview 91 92 CODIC-CARD components 93 99 XS anti-tamper fitting, offline model 100 IBL interior door fittings, accessories, wall models, control units 101 104 CODIC software 105 CODIC BT and CODIC BTL security door fittings and accessories 106 CODIC CC-, CI-key and accessories 107 DORMA Intruder Detection Systems 108 110 PROSIS Jamb-Concealed Locks and Accessories 111 TEGO Glass 112 113 TEGO Connect / Profile 114 118 Service for Installers 119 Service, Training 120 121 Demonstration Aids for Retailers and Fabricators 122 124 Supplement Conditions of the DORMA Companies Relating to Software 125 126

DORMA Your Partners in Europe A - Austria DORMA GmbH+Co. KG Wolfgang Rameseder Reitfeldweg 13 A-4210 Gallneukirchen Tel. +43 72 35 / 63 73 0 Fax +43 72 35 / 67 25 5 B - Belgium DORMA Foquin N. V. Lieven Bauwensstraat 21A B-8200 Brugge Phone: +32 50 / 45 15 70* Fax: +32 50 / 31 95 05* BG - Bulgaria DORMA-BALKAN EOOD Tehnika za vrati str. Akad. Georgy Bonchev, blok 6 BG-1113 Sofia Phone: +359 2 / 70 39 02 Fax: +359 2 / 70 40 03 CH - Switzerland DORMA Schweiz AG Industrie Hegi 1a CH-9425 Thal Phone: +4171 / 8 86 46 46 Fax: +4171 / 8 86 46 56 CZ - Czech Republic DORMA dverní ˇ technika CR, ˇ s.r.o. Vinohradská 184 CZ-13052 Praha 3 Phone: +420 2 / 67 13 21 78 +420 2 / 67 13 21 79 Fax: +420 2 / 67 13 21 71 DK - Denmark DORMA Danmark A/S Sindalvej 6-8 DK-2610 Rødovre Phone: +45 44 / 94 30 77 Fax: +45 44 / 94 95 04 E - Spain DORMA Ibérica, S.A. Camino San Martín de la Vega, 4 E-28500 Arganda del Rey (Madrid) Phone: +34 91 / 8 75 78 50 Fax: +34 91 / 8 75 78 81 EE - Estonia DORMA Representation Estonia Mart Rosin Lootuse pst. 90 EE-11619 Tallinn Phone: +372 / 6 70 70 64 Fax: +372 / 6 70 70 65 F - France DORMA France S.A.S Europarc 42 rue Eugène Dupuis F-94046 Créteil Phone: +33 1 / 41 94 24 00 Fax: +33 1 / 41 94 24 01 FIN - Finland DORMA Finland Oy Tiilenlyöjänkuja 6 FIN-01720 Vantaa Phone: +358 9 / 8 78 91 30 Fax: +358 9 / 8 78 40 67 GB - Great Britain/ Northern Ireland DORMA UK Ltd. Wilbury Way GB-Hitchin Hertfordshire SG4 0AB Phone: +44 14 62 / 47 76 00 Fax: +44 14 62 / 47 76 01 GR - Greece DORMA Representation Greece Panayiotis Bosmis G.Fragouli 3-B GR-17456 Alimos - Athen Phone: +30 1 / 9 94 43 88 Fax: +30 1 / 9 93 86 65 H - Hungary DORMA Magyarország Kft. Szilágyi Erzsébet fasor 40 H-1125 Budapest Tel. +36 1 / 3 92 70 37 Fax +36 1 / 3 92 70 38 HR - Croatia DORMA URED Vladimir Simuncic. ˇ UI. Velimira Skorpika ˇ 10 HR-10090 Zagreb Phone: +385 1 3498 422 Fax: +385 1 3498 466 I - Italy DORMA Italiana S.r.l. Via. A. Canova 44/46 I-20035 Lissone (Ml) Phone: +39 039 / 24 40 31 Fax: +39 039 / 24 40 33 10 IRL - Ireland DORMA Door Controls Ltd. 19, Sandyford Office Park Foxrock IRL-Dublin 18 Phone: +353 1 / 2 95 82 80-82 Fax: +353 1 / 2 95 82 84 L - Luxemburg Joachim Wettach P.O. Box 41 12 07 55068 Mainz Phone: 0 61 36 / 95 33 96 9 Fax: 0 61 36 / 95 33 69 8 LT - Lithunia DORMA Representation Lithunia Uldis Lácis Dzelzavas 76/3-25 LV-1080 Riga Phone: +371 / 2 57 12 72 Fax: +371 / 7 54 62 40 LV - Latvia DORMA Representation Latvia Uldis Lácis Dzelzavas 76/ 3-25 LV-1080 Riga Phone: +371 / 2 57 12 72 Fax: +371 / 7 54 62 40 MK - Macedonia DORMA BALKAN EOOD Tehnika za vrati str. Akad. Georgy Bonchev, blok 6 BG-1113 Sofia Phone: +359 2 / 70 39 02 Fax: +359 2 / 70 40 03 N - Norway DORMA Norge A/S Postboks 195, Alnabru N-0614 Oslo Alfasetveien 1 N-0668 Oslo Phone: +47 23 / 17 68 00 Fax: +47 23 / 17 68 01 NL - Netherlands DORMA van Duin Nederland B. V. Dalwagen 45 NL-6669 CB Dodewaard Phone: +31 488 / 41 81 00 Fax: +31 488 / 41 81 90 P - Portugal DORMA Portugal AV. DE SOUSA CRUZ, N.º 671 - LOJA 9 P-4780-365 SANTO TIRSO Phone: +351 252 860 490 Fax: +351 252 860 499 PL - Poland DORMA Polska Sp. Zo. o. Ul. Warszawska 72 PL-05-520 KONSTANCIN JEZIORNA Phone: +48 22 / 736 59 00 Fax: +48 22 / 736 59 01 RO - Rumania DORMA Representation Rumania Gabriel Gavrilescu Aleea Bran, Nr. 2, Bl. 92 Sc. 1, Ap. 11, Sector 4 RO-75158 Bukarest Phone: +401 / 3 30 05 68 Fax: +401 / 3 30 05 68 RUS - Russia DORMA Representation Moscow Andrei Sakhranov 2-ya Pestchanaya str. 8, apt. 25 RUS-125252 Moscow Phone:+7 095 / 9 46 46 47 Fax: +7 095 / 9 46 46 47 RUS - Russia DORMA Representation St. Petersburg Alexey Gruzdev Svetlanovskij 21, apt. 35 RUS-194223 St. Petersburg Phone: +7 812 / 5 52 68 46 Fax: +7 812 / 5 52 68 46 S - Sweden DORMA Sverige AB Datavägen 20 S-43632 Askim Phone: +46 31 / 28 95 20 Fax: +46 31 / 28 17 39 SK - Slowakian Republic DORMA Slovakei s.r.o. Ruzová dolina 8 SK-82106 ˇ Bratislava Phone: +421 2 / 50 22 12 83 Fax: +421 2 / 50 22 12 86 SLO - Slovenia DORMA Representation Slovenia ICL d.o.o. PE Murska Sobota Plese 9 SLO-9000 Murska Sobota Phone: +386 2 / 5 30 20 10 Fax: +386 2 / 5 30 20 20 TR - Turkey DORMA Kapi Kontrolleri Ltd. Sirketi, Sahrayi Cedid Mah. Mengü Sok., No: 17/6 TR- 81080 Erenköy Istanbul Phone: +90 216 / 360 0056 Fax: +90 216 / 360 1791 UA - Ukraine DORMA Representation Ukraine 15 Kominterna Str. 252032 Kiew Phone: +380 44 / 2 44 38 97 Fax: +380 44 / 2 44 38 97 YU - Republic Yugoslavia DORMA Representation Republic Yugoslavia ELMAT Maksima Gorkog 135 YU-11000 Belgrade Phone: +381 11 / 4 44 73 21 Fax: +381 11 / 4 44 73 21 Security Systems 2

DORMA Your Partners Worldwide America, Africa, Asia, Australia Canada DORMA Door Controls 1680 Courtney Park Drive Unit 13 Mississauga, Ontario L5T 1R4 Phone: +1 905 / 6 70 12 81 Fax: +1 905 / 6 70 58 50 USA/Caribbean and Central America DORMA Architectural Hardware DORMA Drive, Drawer AC Reamstown, Pa. 17567 USA Phone: +1 800 / 5 23 84 83 Fax: +1 800 / 2 74 97 24 (Sales & Production) DORMA Automatics Inc. 375 Prince George's Blvd. Upper Marlboro, MD 20774 USA Phone: +1 877 / 3 67 62 11 Fax: +1 301 / 3 90 55 15 DORMA Glas Inc. 375 Prince George's Blvd. Upper Marlboro, MD 20774 USA Phone: +1 800 / 4 51 06 49 Fax: +1 301 / 3 90 00 11 (DORMA Glas only) South America DORMA Sistemas de Controles para Portas Ltda. Av. Piracema, 1400 Centro Empresarial Tambore CEP 06400 Barueri/Sao Paulo Brasil Phone: +55 11 / 41 91 32 44 Fax: +55 11 / 41 91 21 93 Africa, English Speaking DORMA GmbH + Co. KG P.O. Box 4009 D-58 247 Ennepetal Breckerfelder Straße 42-48 D-58 256 Ennepetal Germany Phone: +49 23 33 / 7 93-0 Fax: +49 23 33 / 7 93-495 Africa, French Speaking DORMA France S.A.S Europarc 42, rue Eugène Dupuis F-94046 Créteil Tel. +33 1 / 41 94 24 00 Fax +33 1 / 41 94 24 01 South Africa DORMA Door Controls (Pty.) Ltd. Kings Court P.O. Box 82182 Southdale 2135 Johannesburg South Africa Phone: +27 11 / 8 30 02 80 Fax: +27 11 / 8 30 02 91 Near East * DORMA GmbH + Co. KG P.O. Box 4009 D-58 247 Ennepetal Breckerfelder Straße 42-48 D-58 256 Ennepetal Germany Phone: +49 23 33 / 7 93-512 Fax: +49 23 33 / 7 93-533 Middle East ** DORMA Gulf Door Controls FZE Jebel Ali Free Zone, Roundabout 8, Unit VC 02 P.O. Box17268 Jebel Ali Dubai United Arab Emirates Phone: +971 48 / 83 90 14 Fax: +971 48 / 83 90 15 DORMA Arabia Automatic Doors Ltd. P.O. Box 1633 Dammam 31441 Kingdom of Saudi Arabia Phone: +966 38 / 47 23 94 Fax: +966 38 / 47 23 68 Far East *** DORMA Far East Pte.Ltd. No. 31 Gul Lane Jurong Singapore 62 94 25 Phone: +65 62 68 76 33 Fax: +65 62 65 79 14 China DORMA Door Controls (Suzhou) Co. Ltd. No. 9, Hong Feng Road Suzhou Singapore Industrial Park Suzhou, 215021 P. R. of China Phone: +86 512 / 67612481 Fax: +86 512 / 67614582 DORMA Door Controls Pte. Ltd. Room 701, Technology Plaza 651 King s Road North Point Hong Kong Phone: +825 / 250 34632 Fax: +825 / 288 75370 Australia **** DORMA Door Controls Pty. Ltd. P.O. Box 1092 Narre Warren Vic 3805 52 Abbott Road Hallam /Victoria 3803 Australia Phone: +61 3 / 97 96 35 55 Fax: +61 3 / 97 96 39 55 DORMA BWN Automatics Pty. Ltd. 46, Abbott Road Hallam / Victoria 3803 Australia Phone: +61 3 / 97 96 41 11 Fax: +61 3 / 97 96 37 67 * Cyprus, Israel, Malta, Pakistan, Sri Lanka ** Bahrain, Egypt, Jordan, Iran, Iraq,Kuwait, Lebanon, Libya, Oman, Qatar, Saudi Arabia, Syria, UAE, Yemen India DORMA Door Controls India Pvt.Ltd. No.14, Basement,Pattullous Road Chennai - 600 002 Phone: +91 44 / 8 58 50 97 Fax: +91 44 / 8 58 50 96 *** Indonesia, Japan, Malaysia, Philippines, Singapore, South Korea, Taiwan, Thailand, Vietnam **** New Zealand and the Pacific Islands Corporate HQ DORMA GmbH + Co. KG P.O. Box 4009 D-58 247 Ennepetal Breckerfelder Straße 42-48 D-58 256 Ennepetal Phone: +49(0)23 33 / 7 93-0 Fax: +49(0)23 33 / 7 93-4 95 www.dorma.com OGRO Beschlagtechnik GmbH Donnenberger Straße 2 D-42 553 Velbert Phone: +49(0) 20 53 / 4 95-0 Fax: +49(0) 20 53 / 4 95-100 DORMA-Glas GmbH P.O. Box 3268 D-32 076 Bad Salzuflen Max-Planck-Straße 37-43 D-32 107 Bad Salzuflen Phone: +49(0) 52 22 / 9 24-0 Fax: +49(0) 52 22 / 9 24-146 www.dorma-glas.com Security Systems 3

Security Systems General Informations List of Symbols Direction of Door Opening General Information 1. Models in special colours are available for: TL-G door terminal enclosures, TV electro-mechanical door locking device, TV-Z 1xx fixing set, security door fittings, internal door fittings and wall models. An additional one-off charge supplementary to the list price indicated is made independent of the quantity ordered to cover our set-up costs. a) TV 199, TV-Z 199 and TL-BR 99 paint sprayed (set-up cost code 56 999 199) at 120.00 net. b) TL-G 399 and/or TL-G 599 powder-coated (set-up cost code 56999299) at 200.00 net. c) Powder coating of security door fittings, interior door fittings and wall models (set-up cost code 19999299) at 180.00 net. d) Metal-finish of safety door fittings, interior door fittings and wall models (set-up cost code 19999399) at 230.00 net. Please send colour sample with enquiries. 2. Special drill hole pattern Door fittings are also available with special drill hole patterns. An additional one-off charge of 125.00 net is made supplementary to the list price indicated, independent of the quantity ordered, to cover our set-up costs (set-up cost code 19999199). 3. Minimum order value For orders under a net value of 100.00 we make a sur charge of 15.00 per order. When ordering, please indicate the colour code you require using RAL conventions. List of symbols Symbols Comments Symbols Comments DIN 18250 Product corresponds to DIN standard 18 250. Product corresponds to Europe standard 179 DIN 18251 Product corresponds to DIN standard 18 251. Product corresponds to Europe standard 60947-5-1 DIN 18252 DIN 40050 Product corresponds to DIN standard 18 252. Product corresponds to DIN-EN standard 40 050. F Products may be employed for applications involving preventive fire protection. The corresponding certificates of approval issued by the MPA are available for examination (only effective in the Federal Republic of Germany). Products carry the MPA/VdS German approval certificate for applications as per DIBt Bulletin 5/98 - Guidelines on electric locking systems for doors used in emergency exits and escape routes - EltVTR, December 97 issue. n Here you will find information on new products, new order no., new colour shades or finishes etc. Products currently undergoing trials in order to satisfy the requirements for the approval certificate as per DIBt Bulletin 5/98. Please ask for current status. Product tested and approved in accordance with VdS (German Association of Property Insurers) guidelines. Direction of Door Opening to DIN/ISO Standard arrangement Spezial arragement Outward LH (ISO 6) Outward RH (ISO 5) Inward LH (ISO 6) Inward RH (ISO 5) Escape direction Security Systems 4

Emergency Exit Control Safety Control DORMA emergency exit control systems have been developed and manufactured in accordance with the state of the art and generally recognised safety regulations. The systems comply with German code of practice Guidelines on electric locking systems for doors used in emergency exits and escape routes (EltVTR, December 1997 edition) published in bulletin 5/98 of the German Institute for Building Technology (DIBt), Berlin. Their suitability has been verified by the MPA NRW (Material Testing Authority) Dortmund and the VdS (Association of Property Insurers) Cologne.! The installer and owner/operator must ensure compliance with the following requirements as these devices must not be allowed to prevent the unhindered escape of persons in the event of an emergency. Use Emergency exit control systems are electric locking systems for doors in emergency exits and escape routes. They are designed to prevent the improper use of emergency exits. When installing and using DORMA emergency exit control systems, it is essential that proper consideration is given to the technical data and local conditions. Building authority applications / approval procedures Situation in Germany: Emergency exit control systems constitute exceptions to current building law and must be approved on the basis of an exemption issued in line with 67 of the Musterbauordnung (German building approval regulations). To this end, the requirements detailed in DIBt 5/98 shall be incorporated as additional regulations in the building approval for the relevant project. Similar regulations may apply in other countries and compliance with these is mandatory. Planning and installation An emergency exit control system consists at least of the following components: Door terminal (TL-G and TL-S), emergency escape control unit (RZ) and electro-mechanical locking element (TV). The following may also be connected to the emergency exit control, depending on the system design: Key switches or access control systems, monitoring and control units, emergency escape/anti-panic locks with automatic locking action (either switch-monitored or of motor lock design), flashing lamp or external alarm siren, automatic swing door operator, power supply unit/power pack, fire and/or hazard detection and alarm system and smoke detectors/switches. The electro-mechanical locking element may only be used on emergency exits in conjunction with DORMA-approved products. The door terminal (for local anti-panic release/emergency opening of door) must be installed in the immediate vicinity of the door handle so that the centre of the emergency pushbutton is at a height of 850 to max. 1200 mm above finished floor level. The emergency-open pushbutton must be indicated by means of an Emergency exit sticker. This sticker should be positioned so that the arrow points towards the emergencyopen pushbutton. In buildings with automatic fire extinguishing equipment, fire alarm and other hazard warning systems, anti-abuse emergency escape doors which are electrically locked must be automatically released for escape on response/activation of these systems. If, during building occupancy, there is a constantly manned control centre with a direct view of the emergency escape doors, the release operation can, instead, be performed from this position. The properties and characteristics of the fire and smoke check doors (fire resistance time, smoke retention/sealing function and automatic closing action) must not be impaired by the installation of the electro-mechanical locking device. In Germany, modifications made to fire doors/barriers rendered necessary for installation of the electro-mechanical locking device, which go beyond the permissible modifications cited in bulletin 1/1996 of the DIBt, require general approval from the building inspectorate responsible and also individual approval from the local building authority. Similar regulations may apply in other countries and compliance with these is mandatory. Only DORMA replacement parts or DORMA-approved accessories may be used. Any work on electrical equipment not operating on protective low voltage must always be performed by suitably qualified electricians. Installation, commissioning and maintenance work may only be performed by qualified personnel authorised by DORMA (see commissioning and maintenance instructions). The keys for the door terminal and emergency exit control box must be kept secure. Keys for products not operating on protective low voltage may only be handed over to suitably qualified electricians. Relevant regulations In Germany compliance with the following standards and directives (current version) must be ensured: DIBt Bulletin 5/98 - Guidelines on electric locking system for doors used in emergency exits and escape routes (EltVTR) DIBt Bulletin 1/96 - Changes and modifications to fire doors/closures DIN VDE 0100, 0800, 0815 Regulations governing the installation of electrical equipment DIN 0833 - Parts 1-3 Requirements in respect of hazard alert systems for fire, intrusion and robbery German building regulations list A, Part 1, No. 6.19 Special building regulations Compliance with similar and more far-reaching national or national regulations, standards, guidelines and directives must be ensured. Security Systems 5

Emergency Exit Control Basic-System Emergency exit control Basic-System Field of application Emergency exit control system of anti-tamper design for retrofitting to individual doors of low-frequency usage. Function Door usually locked but quick and easy to open in an emergency. Electronic emergency exit control systems are best suited to satisfy these contradictory requirements. Special features The system can be both monitored and controlled remotely from a central position, and unlocked in an emergency by fire alarm systems, smoke detectors etc. Following a power failure, the system is automatically re-activated. Item Product Order No. /ea. Qty 1 TL-G 3xx/5xx NT door terminal housing with 230 V power supply unit e.g.: TL-G 320 NT, green (sim. to RAL 6001) 56310320 561.00 2 DORMA TL-S 5N, control and interface board 56030055 134.00 3 TV 1xx electro-magnetic locking device (fail-safe) e.g.: TV 101, silver 56021101 349.00 Options 3A TV-Z 1xx fixing set for flush-closing doors e.g.: TV-Z 101, silver 56520201 71.00 3A TV 2xx electro-magnetic locking device (fail-safe) e.g.: TV 201, silver 56020201 398.00 3B TV 50x electro-magnetic locking device for concealed jamb installation e.g.: TV 501 LH (ISO 6) 56020501 424.00 3B TV-Z 500 mortise latch 56520500 37.50 4 ST keyswitch of anti-tamper design with LED indicator ST 32 56043201 120.00 5 TL-UK concealed door terminal recess box for mounting the door terminal 56510512 82.50 6 TL-BR trim TL-BR 11, white powder-coated (sim. to RAL 9016) 56510411 76.00 7 AS 01 alarm siren 56080100 148.00 8 BL 01 flashing lamp, green 56070120 154.00 9 TE-IF FWS bus hub for connection to the DORMA bus panel 56069911 82.50 TV 230 VAC Recommended cabling Mains feeder: NYM - I 3 x 1.5 System cables: I - Y (ST) Y TL > GMA = 2 x 2 x 0.6 max. 1,000 m TL > TV = 4 x 2 x 0.6 TL > ST = 4 x 2 x 0.6 max. 50 m TL > TG/TE = 4 x 2 x 0.6 max. 1,500 m TL > BL = 2 x 2 x 0.6 max. 50 m TL > AS = 2 x 2 x 0.6 max. 50 m TL-NT and TL-S 5 N Security Systems 6 Prices subject to change without notice 04/08

Emergency Exit Control Basic System, Special Design Emergency exit control Basic system, special design Field of application Emergency exit control system with door terminal in System 55 design for installation in concealed switch boxes, for control of individual doors with low-frequency usage. Function Door usually locked but quick and easy to open in an emergency. Electronic emergency exit control systems are best suited to satisfy these contradictory requirements. Special features This emergency exit control system is perfectly coordinated to the System 55 electrical device design. Combined with the appropriate trim/cover frame, the system can also be installed in external areas (IP 54). Readily expandable with addition of retrofit access control and monitoring functions. Item Product Order No. /ea. Qty 1 DORMA TL-S 55 UP, concealed control unit 56030550 153.00 2 TL-N S 55 concealed emergency pushbutton, System 55 56330500 142.00 3 TL-UP System 55 door terminal TL-ST S 55 W keyswitch, white 56330710 88.50 4 System 55 cover frame (FR = Frame) FR-S 55 3, three-aperture frame, Standard 55, white 56391310 10.50 5 TV 1xx electro-magnetic door locking device (fail-safe) e.g.: TV 101, silver 56021101 349.00 Options 4A DORMA TX 44 cover frame FR-TX44W 1 cover frame, single aperture, IP 44 white 56394110 18.50 4A System 55 cover frame (FR = Frame) FR-TX44A Set 55, set of seals/gaskets for S 55 components 56399000 14.50 5A TV-Z 1xx fixing set for flush-closing doors e.g.: TV-Z 101, silver 56520201 71.00 5B TV 50x electro-magnetic locking device for concealed jamb installation e.g.: TV 501 LH (ISO 6) 56020501 424.00 5B TV-Z 500 mortise latch 56520500 37.50 6 PSU-xx concealed power supply unit e.g.: PSU-24 56030101 102.00 7 RZ 01 stabilised power supply unit, 24 V DC 56030100 147.00 3A Special solution with "lite" access control CODIC MasterCard CMC-Hxx As "lite" stand-alone access control system for issue of up to 99 different authorisation codes, e.g: CMC-H01, silver 19350101 372.00 In this case, the MasterCard keypad reader can replace keyswitch TL-ST S55 W. TV 230 VAC TL S55 Security Systems 7 Prices subject to change without notice 04/08

Emergency Exit Control TMS Standard Emergency exit control TMS Standard Field of application Emergency exit control system of antitamper design for equipping project doors of high-frequency usage. Function Functions additional to that of the basic system, e.g.: short-time, long-time and permanent unlocking, "door open monitoring, anti-tamper and sabotage monitoring, logic gating. All functions can be parameterised via PC. Special features Extensively expandable without additional cabling or hardware replacement; flexible reprogramming capability. Integrated access control. Prepared for connection via LON or LAN, direct parameter configuration via RS 232 interface to bus or conventional systems such as building management control panel and additional control and signalling devices. Item Product Order No. /ea. Qty 1 TL-G 3xx/5xx NT door terminal housing with 230 V power supply unit e.g.: TL-G 320 NT, green (sim. to RAL 6001) 56310320 561.00 2 TL-S TMS 2 control and interface board 56330101 288.00 3 TV 1xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 101 DCW, silver 56320101 346.00 Options 3A TV-Z 1xx fixing set for flush-closing doors e.g.: TV-Z 101, silver 56520201 71.00 3A TV 2xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 201 DCW, silver 56320201 398.00 3B TV 50x electro-magnetic locking device for concealed jamb installation e.g.: TV 501 LH (ISO 6) 56020501 424.00 3B TV DCW adapter 56329001 46.00 3B TV-Z 500 mortise latch 56520500 37.50 4 ST 3 x DCW keyswitch e.g.: ST 32 DCW 56343200 150.00 5 SVP 5xxx, emergency escape lock with automatic locking action e.g.: SVP 5719 15571900 126.00 6 AT 01 DCW surface-mounted parameterisation keypad 56340101 160.00 7 4-port DCW I/O bus interface module DCW I/O module 56350100 144.00 8 AS 01 alarm siren 56080100 148.00 9 BL 01 flashing lamp, green 56070120 154.00 10A TMS LON bus hub module for networking via PC with TMS Soft 56353000 240.00 10B TE-IF FWS bus hub for connection to the DORMA bus panel 56069911 82.50 TV 230 VAC Recommended cabling Mains feeder: NYM-I 3 x 1.5 TL TMS > TV 1xx DCW = 4 x 2 x 0.8 TL TMS > ST 3x DCW = 2 x 2 x 0.8 TL TMS > TE xx = 4 x 2 x 0.8 TL TMS > RM* = 2 x 2 x 0.8 TL TMS > BL* = 2 x 2 x 0.8 LON module > LON gateway = 2 x 2 x 0.8 *via DCW I/O module TL-NT and TL-S TMS 2 Security Systems 8 Prices subject to change without notice 04/08

Emergency Exit Control TMS Standard+ Emergency exit control TMS Standard + Field of application Emergency exit control system of antitamper design for equipping project doors with high-frequency usage and elevated convenience requirements. Function In addition to the functions of the Standard system, the emergency escape lock with automatic locking action and microswitch status monitoring offers authorised personnel elevated user convenience as only one locking operation is required at the cylinder of the lock. At the same time, the security status is optimised by automatic re-activation following door closure and further monitoring functions such as lever handle pre-alarm and door open monitoring. All functions can be parameterised via PC or Palm. Special features Particularly suitable for doors provided as forced entry and rescue entrances for fire brigades and equipped to allow access from the outside via the fire brigade duty key. Prepared for connection via LON and RS 232 interface to bus or conventional systems such as building management control panel and additional control and signalling devices. Item Product Order No. /ea. Qty 1 TL-G 3xx/5xx NT door terminal housing with 230 V power supply unit e.g.: TL-G 320 NT, green (sim. to RAL 6001) 56310320 561.00 2 TL-S TMS 2 control and interface board 56330101 288.00 3 TV 1xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 101 DCW, silver 56320101 346.00 4 SVP 4xxx emergency escape lock with automatic locking action, electrically monitored e.g.: SVP 4719 15471900 221.00 5 SVP-A connection cable e.g.: SVP-A 1000 49932990 42.50 6 KÜ cable loop, reinforced spiral e.g.: KÜ 480 15813000 41.50 7 TMS Soft V 4.0, PC software 56339104 688.00 8A TMS LON bus hub module for networking via PC with TMS Soft 56353000 240.00 8B TE-IF FWS bus hub for connection to the DORMA bus panel 56069911 82.50 9 4-port DCW I/O bus interface module DCW I/O module 56350100 144.00 Options 3A TV-Z 1xx fixing set for flush-closing doors e.g.: TV-Z 101, silver 56520201 71.00 3A TV 2xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 201 DCW, silver 56320201 398.00 3B TV 50x electro-magnetic locking device for concealed jamb installation e.g.: TV 501 LH (ISO 6) 56020501 424.00 3B TV DCW adapter 56329001 46.00 3B TV-Z500 mortise latch 56520500 37.50 9 AS alarm siren 56080100 148.00 10 BL 01 flashing lamp, green 56070120 154.00 TV 230 VAC KÜ SVP 4000 SVP-A TL-NT and TL-S TMS Security Systems 9 Prices subject to change without notice 04/08

Emergency Exit Control TMS Standard, Special Design Emergency exit control TMS Standard, special design Field of application Emergency exit control system with door terminal in System 55 design for installation in concealed switch boxes, for control of individual doors with high-frequency usage. Function Functions additional to that of the basic system, e.g.: short-time, long-time and permanent unlocking, door open monitoring, anti-tamper and sabotage monitoring, logic gating. All functions can be parameterised via PC or Palm. Special features Extensively expandable without additional cabling or hardware replacement; flexible reprogramming capability. Access control via optional System 55 access control reader and SVP 6000. Prepared for connection via LON and RS 232 interface to bus or conventional systems such as building management control panel and additional control and signalling devices. Item Product Order No. /ea. Qty 1 TL-UP System 55 Set E2, pure white, door terminal TL-UP System Set E2 56330110 292.00 2 RZ TMS 2 emergency exit control unit RZ TMS 2 PCB in enclosure with TMS power supply unit 56331100 643.00 3 TV 1xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 101 DCW, silver 56320101 346.00 Options 3A TV-Z 1xx fixing set for flush-closing doors e.g.: TV-Z 101, silver 56520201 71.00 3A TV 2xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 201 DCW, silver 56320201 398.00 3B TV 50x electro-magnetic locking device for concealed jamb installation e.g.: TV 501 LH (ISO 6) 56020501 424.00 3B TV DCW adapter 56329001 46.00 3B TV-Z 500 mortise latch 56520500 37.50 4 SVP 4xxx emergency escape lock with automatic locking action, electrically monitored, only in conjunction with DCW I/O module e.g.: SVP 4719 15471900 221.00 5 SVP 6xxx, fail-secure design, 24 V DC, emergency escape lock with automatic locking action and split lever handle follower, only in conjunction with DCW I/O module e.g.: SVP 6710 A 24 V DC 15671001 416.00 6 SVP-A connecting cable e.g.: SVP-A 1000 49932990 42.50 7 KÜ cable loop, reinforced spiral e.g.: KÜ 480 15813000 41.50 8 TK reed door contact e.g.: TK 210, white 49931210 25.00 9 TMS Soft V 4.0, PC software 56339104 688.00 10 AS 01 alarm siren 56080100 148.00 11 BL 01 flashing lamp, green 56070120 154.00 12A TMS LON bus hub module for networking via PC with TMS Soft 56353000 240.00 12B TE-IF FWS bus hub for connecting to the DORMA bus panel 56069911 82.50 13 CRH-K01 DCW combination access control reader and keypad/hitag 19250501 453.00 230 VAC RZ-TMS TV TL-UP S55 Security Systems 10 Prices subject to change without notice 04/08

Emergency Exit Control TMS Universal Emergency exit control system with integrated access control TMS Universal Field of application Projects with emergency exit doors protected by the TMS system in which a maximum of 250 people have access rights per door. Function Emergency exit control system (TMS) with integrated access control for up to 250 access authorisations. Special features Two functions, one price: the cost of a separate access control system is eliminated for each door equipped with this system. Prepared for connection via LON and RS 232 interface to bus or conventional systems such as building management control systems and additional control and signalling devices. Item Product Order No. /ea. Qty 1 RZ TMS 2 emergency exit control unit RZ TMS 2 PCB in enclosure with TMS power supply unit 56331100 643.00 2 TL-UP System 55 door terminal TL-NC S55 emergency pushbutton/control unit 56330601 192.00 3 TL-UP System 55 door terminal e.g.: TL-ST S55 W, white, keyswitch 56330710 88.50 4 CODIC CARD reader CRH-Gxx DCW e.g.: CRH-G10 DCW, white (sim. to RAL 9010) 19250410 303.00 5 System 55 cover frame (FR = Frame) e.g.: FR-S55 3, triple-aperture frame, Standard 55, white 56391310 10.50 6 TV 1xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 101 DCW, silver 56320101 346.00 7 SVP 2xxx, emergency escape motor lock with automatic locking action e.g.: SVP 2719 49271915 587.00 8 SVP-A connection cable e.g.: SVP-A 1000 49932990 42.50 9 KÜ cable loop, reinforced spiral e.g.: KÜ 480 15813000 41.50 10 SVP-S 2x DCW motor lock control e.g.: SVP-S 22 DCW/LON 15922202 291.00 11 CODIC CARD Software CC-SOFT 19650001 402.00 12 TMS Soft V 4.0, PC software 56339104 688.00 Options 6A TV-Z 1xx fixing set for flush-closing doors e.g.: TV-Z 101, silver 56520201 71.00 9 TK reed door contact e.g.: TK 210, white 49931210 25.00 13 RM smoke detector for use on fire doors 64810001 256.00 14 TMS LON bus hub module for networking via PC with TMS Soft 56353000 240.00 230 VAC RZ-TMS TV KÜ SVP 2000 SVP-A TL-UP S55 Security Systems 11 Prices subject to change without notice 04/08

Individual Application Solutions Children s Nursery/Kindergarten Flexible entry and exit control including emergency exit security Example: Children s Nursery/Kindergarten Terms of reference The main entrance door needs to be opened from the outside from 7 am to 9 am so that parents and children have free access to the interior. After 9 am, no further people are to be allowed uncontrolled entry or exit. From this time on, the door must also be locked from the outside. Solution Access from the outside is enabled between 7 am and 9 am by the integrated long-time control. After 9 am, only controlled entry/exit is possible. The door is locked on the inside by an emergency exit control system. If adults wish to leave the nursery, they can open the doors via a pushbutton located at a height of 1.8 metres. Once the door is closed, it re-locks automatically. Access from the outside is via the DORMA SVP 6710 emergency escape lock with automatic locking action. Item Product Order No. /ea. Qty 1 TL-G 3xx/5xx NT door terminal housing with 230 V power supply unit e.g.: TL-G 320 NT, green (sim. to RAL 6001) 56310320 561.00 2 TL-S TMS 2 control and interface PCB 56330101 288.00 3 TV 1xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 101 DCW, silver 56320101 346.00 4 SVP 6xxx, fail-secure design, 24V DC, emergency escape lock with automatic locking action, microswitch monitoring and split lever handle follower e.g.: SVP 6710 A 24 V DC 15671001 416.00 5 SVP-A connection cable e.g.: SVP-A 1000 49932990 42.50 6 KÜ cable loop, reinforced spiral e.g.: KÜ 480 15813000 41.50 7 Manual pushbutton from the switch range for authorised opening from the inside, installation height approx. 180 cm 5157033332 28.00 Options 3A TV-Z 1xx fixing set for flush-closing doors e.g.: TV-Z 101, silver 56520201 71.00 8 AT 01 DCW surface-mounted parameterisation keypad 56340101 160.00 9 AS 01 alarm siren 56080100 148.00 10 BL 01 flashing lamp, green 56070120 154.00 TV pushbuttons inside and out 230 V AC KÜ SVP 6000 SVP-A TL-NT and TL-S TMS 2 Security Systems 12 Prices subject to change without notice 04/08

Individual Application Solutions Bidirectional Escape Route Bidirectional escape route Example: Office floor Terms of reference In a large office block, one floor is split and rented to different entities. The floor is separated by a door. Each zone is to be protected, but in the case of an emergency, the escape route of each entity leads through the area rented by the other entity. Solution The doors are equipped with an emergency exit control terminal on each side. These can be used to open the door in an emergency, while keeping them closed and locked under normal circumstances. The keyswitch of the door terminal is programmed exclusively for alarm acknowledgement and re-locking. Special features Prepared for connection via LON and RS 232 interface to bus or conventional systems such as building management control panel and additional control and signalling devices. Flush-mounted (FM) System 55 solution Item Product Order No. /ea. Qty 1 RZ TMS 2 PCB in housing with TMS power supply unit, RZ TMS 2 emergency exit control unit 56331100 643.00 2 TV 1xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 101 DCW, silver 56320101 346.00 3 TL-UP System 55 Set E2, pure white, door terminal - inside TL-UP System Set E2, terminal switch program 56330110 292.00 4 TL-UP System 55 Set E2, pure white, door terminal - outside TL-UP System Set E2, terminal switch program 56330110 292.00 2A Options TV-Z 1xx fixing set for flush-closing doors e.g.: TV-Z 101, silver 56520201 71.00 Surface-mounted (SM) solution Item Product Order No. /ea. Qty 1 TL-G 3xx/5xx NT door terminal housing with power supply unit 230 V e.g.: TL-G 320 NT, green (sim. to RAL 6001) 56310320 561.00 2 TL-S TMS 2 control and interface PCB 56330101 288.00 3 TL-G 3xx/5xx door terminal housing for installing the TL-S control and interface PCB e.g.: TL-G 320, green (sim. to RAL 6001), SM terminal 56010320 345.00 4 TL-S DCW terminal connection PCB 56330201 87.50 5 TV 1xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 101 DCW, silver 56320101 346.00 5A Options TV-Z 1xx fixing set for flush-closing doors e.g.: TV-Z 101, silver 56520201 71.00 230 V AC RZ-TMS TV TL-UP S55 TL-UP S55 Security Systems 13 Prices subject to change without notice 04/08

Individual Application Solutions Airlock Doors Controlled entry/exit via airlock doors Example: Court building Terms of reference Controlled entry/exit is to be restricted to single users or a limited number of people. Solution Entry and exit events can be specifically monitored and controlled via airlock doors. These may be equipped with an emergency exit control in conjunction with an access control system and SVP 2000 emergency escape locks with automatic locking action, or instead of the SVP, with electric strikes. Functional description In this application, two emergency exit doors are designed as a deliberate airlock. At rest, both doors are closed and locked. An activa-tion signal emitted via a pushbutton, access control system etc. unlocks the door concerned for an adjustable time between 3 and 180 sec. Until the door is relocked, the activation signal for opening the other door remains suppressed. Even if the activation signals are emitted simultaneously, the opening of both doors at the same time is not possible. Release of the door in the event of an emergency/panic situation is effected through operation of the emergency pushbutton or emergency unlocking by a central hazard alert panel (GMA) with audible alarm emission. Specific requirements, e.g. unlocking times or duration of pre and main alarms freely programmable via parameterisation keypad/software at any time. For connection via LON and RS 232 interface to bus or conventional systems such as building management control panel and additional control and signalling devices. Item Product Order No. /ea. Qty 1 RZ TMS 2 PCB in enclosure with TMS power supply unit, RZ TMS 2 emergency exit control unit 56331100 643.00 2 RZ TMS 2 24V emergency exit control unit in housing without power supply unit 56331124 450.00 /2 pcs. 3 TV 1xx DCW electro-magnetic locking device (fail-safe) e.g.: TV 101 DCW, silver quantity: 2 units; 346.00 each 56320101 692.00 4 TL-UP System 55 Set E2, pure white, door terminal TL-UP System Set E2 quantity: 2 units, 292.00 each 56330110 584.00 5 SVP 2xxx, emergency escape motor lock with automatic locking action e.g.: SVP 2719 quantity: 2 units, 587.00 each 49271915 1,174.00 6 SVP-A connection cable e.g.: SVP-A 1000 quantity: 2 units, 42.50 each 49932990 85.00 7 KÜ cable loop, reinforced spiral e.g.: KÜ 480 quantity: 2 units, 41.50 each 15813000 83.00 8 TK reed door contact e.g.: TK 210, white quantity: 2 units, 25.00 each 49931210 50.00 9 SVP-S 2x DCW motor lock control e.g.: SVP-S 22 DCW/LON quantity: 2 units, 291.00 each 15922202 582.00 3A 4A 4A Options TV-Z 1xx fixing set for flush-closing doors e.g.: TV-Z 101, silver quantity: 2 units, 71.00 each 56520201 142.00 TL-G 3xx/5xx door terminal housing for installing the TL-S control and interface PCB e.g.: TL-G 320, green (sim. to RAL 6001), SM terminal quantity: 2 units, 345.00 each 56010320 690.00 TL-S DCW terminal connection PCB quantity: 2 units, 87.50 each 56330201 175.00 230 V AC TV RZ-TMS SVP-S KÜ SVP 2000 SVP-A TL-UP S55 Security Systems 14 Prices subject to change without notice 04/08

Individual Application Solutions Psychiatric Clinic Centrally controlled emergency exit security system Example: Psychiatric clinic Terms of reference In the event of danger, certain doors must guarantee reliable emergency escape while in every-day circumstances the same doors must be reliably secured against the possibility of patients absconding. Solution The individual emergency escape doors do not have their own emergency pushbutton. Instead, these are installed decentrally in the nurse s room and/or centrally in a continuously manned control unit for all the doors, or in groups. The lock cylinder in the SVP 4000 enables authorised personnel to pass through the doors whenever required. An alternative means of access can be provided by the CODIC CARD reader as shown in the photo below. Functional description Security system based on four-wire bus technology, suitable for use in emergency exits and escape/rescue routes for locking the emergency escape doors to prevent unauthorised usage, in accordance with German DIBt 5/98 and German Building Regulations List A Part 1. For special applications e.g. in psychiatric clinics, normally locked departments of hospitals, homes for the aged and care homes, and for institutions in which no local door release is desirable. The legal prerequisite for such systems is that the doors are visible from a constantly manned central control position and that, located in this control position, is a release means offering the same reliability of operation as that available with the emergency pushbutton in the door terminal. With short-time unlocking (3 180 sec.), long-time unlocking (5 60 minutes) and permanent unlocking; all functions freely parameterisable. Item Product Order No. /ea. Qty 1 RZ TMS 2 emergency escape control unit RZ TMS 2 PCB in housing with TMS power supply unit, I/O, 56331100 643.00 2 SVP 4xxx emergency escape lock with automatic locking action, electrically monitored e.g.: SVP 4719 15471900 221.00 3 SVP-A connecting cable1 z. B.: SVP-A 1000 49932990 42.50 4 KÜ cable loop, reinforced spiral e.g.: KÜ 480 15813000 41.50 5 4-port DCW I/O bus interface module 56350100 144.00 6 ST 3x DCW keyswitch e.g.: ST 32 DCW 56343200 150.00 /2 pcs. 7 TV 50x electro-magnetic locking device for concealed jamb installation e.g.: TV 505, LH (ISO 6) quantity: 2 units, 424.00 each 56020505 848.00 8 TV DCW adapter quantity: 2 units, 46.00 each 56329001 92.00 9 TV Z 500 mortise latch quantity: 2 units, 37.50 each 56520500 75.00 10 Connection to DORMA control panel Special accessory Customer-specific requirements, e.g. other unlocking times or the duration of pre and main alarms, can be freely programmed via parameterisation keypad or configuration software at any time Access by authorised personnel with automatic re-locking and door open monitoring. Activation by ST32 DCW keyswitch and/or access control systems. Discrete alarm for hold-open of the door beyond the specified time frame. Release of the door by operation of the emergency pushbutton in the central, continuously manned control position or emergency unlocking via a central hazard alert panel (GMA) with simultaneous audible alarm. Free access by simply unlocking the door lock or remote unlocking via access control, etc. with subsequent timed re-engagement of the lock, or permanent unlocking. Prepared for connection via LON and RS232 interface to bus or conventional systems such as building management control panel and additional control and signalling devices. 230 V AC RZ-TMS I/O module TV 500 DCW KÜ SVP 4000 SVP-A ST TE Security Systems 15 Prices subject to change without notice 04/08

Emergency Exit Systems TL Door Terminals Accessories TL-G 3xx / 5xx Anti-tamper door terminal of powder-coated aluminium alloy, degree of protection IP 40, for receiving the TL-S control and interface boards, with LED-illuminated red emergency pushbutton as per EN 60947-1-1, positive opening action, and integrated alarm siren with adjustable volume > 100 db. High-intensity illuminated emergency pushbutton surround with visual indication of the lock status (unlocked = green, locked = red) and visual alarm by yellow flashing light in the event of tamper of authorised/valid operation of the emergency pushbutton. Very easy fitting of the terminal top section and bottom section by means of lock cylinders accessible from the front, and hinge on upper section. Lockable hinged emergency pushbutton cover with anti-tamper contact and transparent lens of non-splinter safety glass. Breakable safety glass with protective film as option. Integrated key switch and momentary contact control mechanism. Dimensions (W x H x D): approx. 90 x 260 x 84 mm...prepared for Europrofile half cylinder by others to DIN 18252 (locking cam centre 30-32.5 mm, overall length 40.5-43.5 mm), locking cam position bottom right (max. 45º) TL-G 320 green (similar to RAL 6001) 56010320 1.611 345.00 TL-G 311 white (similar to RAL 9016) 56010311 1.644 345.00 TL-G 304 stainless steel finish 56010304 1.619 451.00 TL-G 399 spezial finish (see page 4 for surcharge) 56010399 1.650 380.00...prepared for round half cylinder, 22 mm dia., by others (locking cam centre 30-32.5 mm, overall length 40.5-43.5 mm), locking cam position bottom right (max. 45º) TL-G 520 green (similar to RAL 6001) 56010520 1.650 345.00 TL-G 511 white (similar to RAL 9016) 56010511 1.650 345.00 TL-G 504 stainless steel finish 56010504 1.600 451.00 TL-G 599 spezial finish (see page 4 for surcharge) 56010599 1.650 380.00 TL-G 3xx / 5xx NT 230 V Anti-tamper door terminal of powder-coated aluminium alloy, degree of protection IP 40, for accommodation of control and interface board TL-S TMS, with integrated power supply and LED-illuminated red emergency pushbutton as per EN 60947-5-1, positive opening action, and integrated alarm siren with adjustable volume > 100 db. Intensely illuminated emergency pushbutton surround with visual display of the lock status (unlocked = green, locked = red) and visual alarm by yellow flashlight in the event of tamper and operation of the emergency button. Very easy fitting of the terminal top section and bottom section by means of lock cylinders which are accessible from the front, and hinge on upper section. Lockable hinged cover of the emergency pushbutton with anti-tamper contact and transparent lens of non-splinter safety glass. Breakable safety glass with protective film as option. Integrated key switch and momentary contact control mechanism. Power pack: Power supply data: 230 V AC, ± 10% Operating voltage: 24 V DC Current consumption max.: 1 A Temperature range: -20 up to +50 C Dimensions (W x H x D): approx. 90 x 260 x 84 mm... prepared for Europrofile half cylinder accord. to DIN 18252 (locking cam centre 30-32.5 mm, overall length 40.5-43.5 mm), locking cam position bottom right (max. 45 ) TL-G 320 NT green (similar to RAL 6001) Kaste schwarz 56310320 1.800 561.00 TL-G 311 NT white (similar to RAL 9016) Kaste schwarz 56310311 1.780 561.00 TL-G 304 NT stainless steel finish Kaste schwarz 56310304 1.780 666.00 TL-G 399 NT spezial finish Kaste schwarz 56310399 1.780 602.00... prepared for round half cylinder, 22 mm dia., (locking cam centre 30-30.5 mm, overall length 40.5-43.5 mm), locking cam position bottom right (max. 45 ) TL-G 520 NT green (similar to RAL 6001) Kaste schwarz 56310520 1.800 561.00 TL-G 511 NT white (similar to RAL 9016) Kaste schwarz 56310511 1.800 561.00 TL-G 504 NT stainless steel finish Kaste schwarz 56310504 1.800 666.00 TL-G 599 NT spezial finish Kaste schwarz 56310599 1.800 602.00 Security Systems 16 Prices subject to change without notice 04/08

Emergency Exit Systems TL Door Terminals Accessories TL-UK recess box for flush installation of door terminal Zinc-plated build-in casing for flush installation of door terminal with attachment collars as wall anchors. Adjustable base plate for correction of vertical tolerances of installation. Prepared for front and rear cabling. Dimensions (W x H x D) approx.: 113 x 311 x 77 mm 56510512 1.059 82.50 TL-BR trim Height adjustable for correction of setting depth of door terminal into TL-UK.Dimensions (W x H x D) approx.: 130 x 331 x 4 mm TL-BR 08 yellow green fluorescent 56510408 0.263 137.00 TL-BR 11 white powder-coated (similar to RAL 9016) 56510411 0.274 76.00 TL-BR 04 stainless steel finish 56510404 0.270 137.00 TL-BR 99 spezial finish (see page 4 for surcharge) 56510499 0.270 144.00 TL-Z 03 single Europrofile half cylinder with 3 keys With adjustable locking cam (lever), suitable for use with DORMA TL-G, TE, ST and lockable sheet steel enclosures of NT 1224 N, RZ-12 N, SVP-S 25 (not suitable for master-key or keyed-alike systems). 56510300 0.020 20.00 TL-Z 04 spare lens for TL-G 3xx / 5xx emergency pushbutton cover Breakable safety glass with protective film, pack of 5 56510400 0.100 19.00 TL-Z 05 spare lens for emergency pushbutton cover TL-G 3xx / 5xx, 2 mm thick, non-breakable 35568501140 0.020 19.00 Inspection plaques for emergency exit systems Self-adhesive inspection plaques for documenting correct inspection and maintenance of DORMA emergency exit systems with special documents pen 56520010 0.100 35.00 Inspection logbook/operating manual for emergency exit systems for documenting the correct inspection and maintenance of up to 10 doors with DORMA emergency exit systems Can be obtained via the DORMA media ordering system (www.dorma.de) Conventional systems TL-S5, etc. WN No. 056336 Bus systems WN No. 055369 Free of charge Free of charge Security Systems 17 Prices subject to change without notice 04/08

Emergency Exit Systems TL Door Terminals Accessories DORMA TL-S 5 N control and interface board TL-S control and connection boards for insertion into TL-G door terminal body Plug-in interface modules for activation of control and indication functions. Volume control adjustable > 100 db, with optional connection to integral or external oscillator for variable audible alarms. TL-S2 control and interface board for use as an emergency stop control for electrical machinery and systems. Power supply data: 24 V DC ±10 % Current consumption max.: approx. 50 ma when circuit closed approx. 85 ma (emergency mode) Contact rating: Emergency-open pushbutton max. 1.7 A inductive/ohmic key switch max. 1.0 A inductive/ohmic TL-S2 56030020 0.100 90.00 for installation in TL-G TMS housing with integrated power supply unit, or TL-G housing with power supply unit type DORMA RZ-01/NT 1224, or for connection to 24V DC power supply by others. Designed for connection of max. two TV electronic exit bolts/keeps/locking devices, ST key switch or access control system by others, TG/TE remote control and monitoring panel, BL flushing lamp or AS external alarm siren, GMA hazard alert/building control panel and/or BMA fire alarm panel or RM smoke detector activated via floating NC contact. Collective alarm checkback/indication via PFS switched floating output, also suitable for optional CCTV applications. Automatic re-activation following power failure. Activation of the integrated permanent unlocking system via keyoperated momentary contact switch. A short timer controlled unlocking operation with automatic re-activation after 10 (5) seconds may be set instead of the permanent unlocking feature on the control PCB. Designed for installation in door terminal housing DORMA TL-G TMS or TL-G, volume control > 100 db, with optional internal/external oscillator for differentiated alarm emission. Power supply data: 24 V DC ± 10% Current input max.: approx. 65 ma approx. 110 ma (emergency mode) TL-S 5 N 56030055 0.110 134.00 DORMA TL-S 55 UP, flush-mounted control unit Control unit for emergency exits and escape routes, Basic Design model. The TL-S 55 UP control unit is connected to the TL-N S 55 emergency pushbutton unit and TL-ST S 55 key switch by means of plug-in connectors / ribbon cables. Installation is in three or four flush-mounted boxes positioned one above the other. The lighting module of the TL-N S 55 emergency pushbutton unit gives a visual indication of the lock status (unlocked = green, locked = red), and visual alarm by yellow flashing light in the event of either a tamper attempt or authorised/valid operation of the emergency pushbutton. The functions of the TL-ST S 55 key switch are to unlock/lock the door-locking element and to acknowledge the alarm signal. Supplied with covers in white, anthracite and silver. Connections for: smoke detector and external anti-tamper circuit PFS no-volt (floating) switching contact (activated by alarm signal) TL-ST UP key switch push-on connector to TL-N UP emergency pushbutton door-locking element control panel Adjustable settings: automatic relocking active/inactive relocking time 5/10 seconds Technical data: supply voltage range: 24 V DC ± 10% total power consumption: max. 150 ma operating temperature range: 0º C to 70º C contact rating (PFS): 24 V; 0.5 A inductive; 1.0 A ohmic TL-S 55 UP 56030550 0.290 153.00 Frame and accessories see page 41 and 42 Security Systems 18 Prices subject to change without notice 04/08

055734-01-1-40 DORMA GmbH + Co. KG Security Systems RZ Emergency Exit Controls NT Power Supply Units Scheibe eindr cken push for emergency TL-N S 55 surface-mounted emergency pushbutton, System 55 Emergency pushbutton for Basic Design emergency exit control system. Emergency pushbutton for installation in standard switch boxes (62 mm deep) to DIN. Also suitable for emergency shutdown of automatic operators, machines or other devices, with LED-illuminated, red emergency pushbutton corresponding to EN 60947-5-1, with positive opening action, brightly lit emergency pushbutton surround with optical indicator of the lock status (unlocked = green, locked = red); visual alarm provided by yellow flashing light to signal tamper/sabotage attempts and emergency pushbutton operation; audible alarm via integral alarm siren. Antitamper emergency pushbutton cover with glass lens of shatter-proof safety glass. All cover trims from the System 55 switch range and stainless steel unit with adapter frames can be used. Power supply data: 24 V DC Contact rating: Emergency-open pushbutton max. 2.5 A inductive/ohmic TL-N S55 56330500 0.110 142.00 System 55 accessories TL-Z N JUNG LS 990 Adapter set for System 55 emergency pushbutton in JUNG LS 990, alpine white. 56399901 40.00 TL-Z N JUNG ES stainless steel Adapter set for System 55 emergency pushbutton in JUNG ES 56399902 40.00 Surface-mounted key switch Keyswitch for emergency exit control, Basic Design and TMS versions. TL-ST PZ S55 prepared for Europrofile single cylinder by others to DIN 18252, (locking cam centre 30-32.5 mm, overall length 40.5 43.5 mm), locking cam position left (90 ) TL-ST S55 W white 56330710 0.130 88.50 TL-ST S55 S silver 56330701 0.133 88.50 TL-ST S55 A anthracite 56330715 0.130 88.50 TL ST JUNG LS 990 Keyswitch for emergency exit control, Basic Design or TMS type, for integration in JUNG flush-flat switches TL ST JUNG LS 990 alpine white 56330720 93.50 TL ST JUNG stainless steel Keyswitch for emergency exit control, Basic Design or TMS type, for integration in JUNG flush-flat switches TL-ST JUNG ES 56330721 93.50 PSU-xx flush-mounting power supply unit Switched power supply unit to EN 60950 for installation in a standard device box for DC power supply to DORMA electric strikes, locks or control units. Power supply: 230 V AC ± 10% 50/60Hz Output voltage: PSU-24 24 V DC Output current: 12 W Dimensions: 51 x 51 x 24 mm (max. diagonal 55 mm) Installation in standard device box (65 mm diameter) PSU-24 56030101 0.110 102.00 TL-S8 control and interface board (until 6/2007) for operation by power supply unit RZ 01/NT 1224 or 24 V DC power supply by others 56030080 0.323 278.00 Security Systems 19 Prices subject to change without notice 04/08

Security Systems TL Door Terminals Swiss Model Ordering and supply via DORMA Schweiz AG (DORMA Switzerland) TL-UP set, Feller Edizio design Door terminal for Basic Design emergency exit control system. For installation in standard device boxes, comprising: TL-N emergency pushbutton, keyswitch TL-ST for switching cylinder provided by others (e.g. KABA, 1007F) and concealed control unit TL-S UP, pre-installed on baseplate with triple-unit frame-type trim corresponding to the Feller Edizio due design. Illumination module for emergency pushbutton unit for optical display of the lock status (unlocked = green, locked = red); visual alarm provided by yellow flashing light to signal tamper/sabotage attempts and emergency pushbutton operation. Locking/unlocking of the TV electronic exit bolt/keep and alarm acknowledgement by keyswitch. Prepared for connection of: electronic exit bolts/keeps TV 10x, TV 20x, TV 50x smoke detector and external anti-tamper circuit control panel PFS no-volt (floating) switch contact (activated by alarm signal) Adjustable settings: automatic relocking active/inactive relocking time 5/10 seconds Technical data: Supply voltage range: 24 V DC ± 10% Total power consumption: max. 150 ma Operating temperature range: 0 to 70 Contact rating (PFS): 24 V; 0.5 A inductive; 1.0 A ohmic TL-UP F31, door terminal, complete with triple-unit frame-type trim, white 56330941 428.00 TL-UP F32, door terminal, complete with triple-unit frame-type trim, signal green 56330942 428.00 TL-N, Feller Edizio design Emergency pushbutton for Basic Design emergency exit control system. For installation in standard device boxes, comprising: TL-N emergency pushbutton, pre-installed on baseplate with single frame-type trim, Feller Edizio due design. For the emergency shutdown of automatic operators, machines or other devices, with LED-illuminated, red emergency pushbutton corresponding to EN 60947-5-1, with positive opening action, brightly lit emergency surround with optical indicator of the lock status (unlocked = green; locked = red); visual alarm provided by yellow flashing light to signal tamper/sabotage attempts and emergency pushbutton operation; audible alarm via integral alarm siren. Anti-tamper emergency pushbutton cover with lens of shatter-proof safety glass. TL-N F11, emergency pushbutton, with single-unit frame-type trim, white 56330541 163.00 TL-N F12, emergency pushbutton, with single-unit frame-type trim, signal green 56330542 163.00 TL-N F13, emergency pushbutton, with single-unit frame-type trim, glass/white 56330543 206.00 TL-N F14, emergency pushbutton, with single-unit frame-type trim, chrome steel/white 56330544 206.00 TL-ST Feller Edizio design Key switch for Basic Design emergency exit control system. For switching cylinder provided by others (e.g. KABA 1007F), pre-installed on baseplate with single-unit frame-type trim type Feller Edizio due. TL-ST F11, keyswitch, with single-unit frame-type trim, white 56330741 80.00 TL-ST F12, keyswitch, with single-unit frame-type trim, signal green 56330742 80.00 TL-ST F13, keyswitch, with single-unit frame-type trim, glass/white 56330743 122.00 TL-ST F14, keyswitch, with single-unit frame-type trim, chrome steel/white 56330744 122.00 Security Systems 20 Prices subject to change without notice 04/08

Security Systems NT Power Supply Units USV RZ 01 stabilised 24 V DC power supply units Power supply data: 230 V AC ± 10 %, 16 VA, max. current output 600 ma. RZ-S01 power supply board For insertion in and operation of RZ 12 emergency exit control.dimensions (W x H x D): approx. 130 x 70 x 40 mm 56030199 0.710 128.00 RZ 01power supply unit For connection of one TL-S 5/8, TL-S TMS control and connection board, in plastic housing, degree of protection: IP class 21, with LED for status indication, alternatively for use as power supply unit for RM smoke detectors. Dimensions (W x H x D): approx.: 160 x 80 x 50 mm 56030100 0.930 147.00 NT-S 24-1.5 (power supply module without housing) NT 24-1.5 (NT-TMS in housing) Power supply unit for connection of a control/interface board type TL-S5, TL-S TMS or TL-S8, in IP 21 plastics housing, with LED indicators, also suitable as power supply unit for RM smoke switch or SVP-S 2x emergency escape lock and SVP-S 2 DCW. Dimensions (W x H x D) approx.: 200 x 120 x 75 mm Power supply data: 230 V AC ± 15% Output voltage: 24 V DC, max. 1.5 A NT-S 24-1.5 56332000 0.330 184.00 NT 24-1.5 56332100 214.00 IRS power pack 12 V AC Discontinued product lines Note: Product with different discount structure! 90700037 0.895 103.00 ZM IRS 24 n 12 V DC power pack 16500000085 64.00 NT 1224 stabilised power pack With 30 V regulated battery recharge and exhaustive discharge protection, optical indication of power failure on monitoring panel possible via floating change-over contact. Output supply data: 12 V, 1 A; 24 V, 1.5 A Contact rating: 24 V DC, 0.5 A inductive, 1.0 A ohmic NT 1224 switched power supply module, IP class 20 protection, with 2-pole-and-earth mains plug For operation with 230 V AC ±10 % power supply; max. 100 VA input; output contacts mounted on screw terminal strips. Dimensions (W x H x D) approx.: 195 x 175 x 120 mm 56122400 4.990 668.00 NT 1224 N emergency power pack Power supply module installed in sheet steel enclosure, degree of protection: IP class 30, with cover contacts, lockable via Euro-profile half cylinder (by others) according to DIN standard 18 252, and prepared for installation of AP 3034 emergency back-up power battery. Dimensions (WxHxD) approx.: 305 x 380 x 126 mm Power and output supply data: 230 V AC ± 10% 12 V, 1 A 24 V, 1.5 A Contact rating: 24 V DC, 0.5 A inductive, 24 V DC, 1.0 A ohmic 56126200 9.300 765.00 AP 3034 emergency back-up power battery Plug-in connected emergency supply, 30 V / 3.0 Ah for NT 1224, to maintain operation of emergency exit or door security system up to approx. 1 h at max. charge of 12 V, 1 A and 24 V, 1.5 A in the event of power failure or, voltage dip. 56623400 4.692 222.00 USV MT 700 VA emergency UPS module Uninterruptible power supply module for incorporation in 230 V cable, 700 VA. Housing dimensions (W x H x D): approx. 120 x 160 x 360 mm Note: Product with different discount structure! 05094531332 13.000 623.00 Security Systems 21 Prices subject to change without notice 04/08

Security Systems TV Electronic Exit Bolt / Keep Accessories TV 1xx electronic exit bolt (fail-safe) With anti-tamper and door monitoring contacts, integrated positiveaction monitoring of TV active /inactive states; in corrosion-resistant and tamper-proof metal housing, -paint-sprayed... Standard kit includes holder, shim plate set and screw pouch. For optional connection to RZ 1x emergency exit controls or door terminals with integral TL-S5/TL-S8 control and connection boards Dimensions (WxHxD) approx.: 190 x 55 x 80 mm Power supply data: 24 V DC ±10 % Current consumption max.: 250 ma Contact rating: 24 V DC, 0.5 A inductive, 1.0 A ohmic Recommended cable: I-Y (ST) Y4 x 2 x 0.6... TV 101 silver 56021101 1.531 349.00... TV 103 dark brown 56021103 1.537 349.00... TV 111 white (similar to RAL 9016) 56021111 1.532 349.00... TV 104 stainless steel finish 56021104 1.250 480.00... TV 199 spezial finish (see page 4 for surcharge) 56021199 1.550 383.00 TV-Z 01 shim plate set for adjusting holder position in the event of wide fixing tolerances (2 x 1 mm and 1 x 3 mm thick) 56520101 0.046 7.10 TV 2xx door locking device (fail-safe principle) Electro-magnet with anti-tamper and door monitoring contacts plu integrated positive-action monitoring of TV active/inactive status. In corrosion-resistant and tamper-proof metal housing, paint-sprayed. Standard kit includes anchor plate (also for fire doors) and fixings. Max. holding force per Requirements for electrical locking systems on doors in emergency escape routes (EltVTR) with side-load-immune release. For optional connection to RZ 1x emergency exit control or door terminals with TL-S5/TL-S8 control and interface boards. Dimensions (WxHxD) approx.: 190 x 55 x 80 mm Power supply data: 24 V DC ±10 % Current consumption max.: 250 ma Contact rating: 24 V DC, 0.5 A inductive 24 V DC, 1.0 A ohmic Recommended cable: I-Y (ST) Y4 x 2 x 0.6... TV 201 silver 56020201 3.178 398.00... TV 203 dark brown 56020203 2.100 398.00... TV 211 white (similar to RAL 9016) 56020211 2.000 398.00... TV 204 stainless steel finish 56020204 3.187 522.00... TV 299 spezial finish (see page 4 for surcharge) 56020299 3.000 429.00 TV-Z 1xx fixing system for flush doors Galvanised steel angle bracket with paint sprayed... aluminium cover (prevents access to screws). Dimensions (W x H x D) approx.: 190 x 58 x 84.5 mm... TV-Z 101 silver 56520201 1.070 71.00... TV-Z 103 dark brown 56520203 1.070 80.50... TV-Z 111 white (similar to RAL 9016) 56520211 1.070 80.50... TV-Z 104 stainless steel finish 56520204 1.070 157.00... TV-Z 199 spezial finish (see page 4 for surcharge) 56520299 1.070 87.50 DORMA TV-Z 015 Fixing system for installing DORMA TV-1xx/TV 2xx electronic exit bolts/keeps to narrow-stile steel and timber frames. Galvanised steel plate. Dimensions (W x H x D): approx. 190 x 5 x 80 mm.... TV-Z 015 56520015 0.500 21.00 Security Systems 22 Prices subject to change without notice 04/08

Security Systems TV Electronic Exit Bolt / Keep Accessories 68 ## 68 # TV 50x electronic exit keep for concealed jamb installation With integrated checkback contacts for monitoring of TV active/inactive states. Supply set includes flanged strike plate and screw pouch. Guarantees jam-free opening of emergency exit under loads up to 5.5 kn, maximum holding force approx. 7.5 kn. For optional connection to RZ 1x emergency exit controls or door terminals with integral TL-S 5/TL-S8 control and connection boards and by means of TV 5x DCW adapter to all TMS systems. Dimensions (W x H x D) approx.: TV 50x (body without strike plate): 23 x 134 x 39 mm Power supply data: 24 V DC + /-5 % Current consumption max.: 160 ma Contact rating: 24 V DC, 0.5 A inductive 24 V DC, 1.0 A ohmic Recommended cable: I-Y(ST) Y4 x 2 x 0.6... TV 501 left-handed (ISO6) 56020501 0.863 424.00... TV 502 right-handed (ISO5) 56020502 0.862 424.00.. with angle strike plate 30 x 48 x 220 x 3 mm for over-rebated doors... TV 505 left-handed (ISO6) 56020505 0.675 424.00 TV 506 right-handed (ISO5) 56020506 0.680 424.00... with flat strike plate 25 x 200 x 3 mm for flush-closing doors, also available for Schüco fire and smoke check doors... TV 507 left-handed (ISO6) 56020507 0.680 424.00 TV 508 right-handed (ISO5) 56020508 0.680 424.00... with flat strike plate for flush-closing doors with latch mechanism TV-Z 500 mortice latch Discontinued product lines as counterpart to TV 500 for leaf intallation 56520500 0.200 37.50 TV-Z 500 Schüco for Schüco Firestop Discontinued product lines 16500000084 84.50 TV-Z 510 Mortise latch lock with adjustable latch as counterpart to TV 50x for leaf installation Forend dimensions: 24 x 110 mm 15198124 37.50 Forend dimensions: 24 x 110 mm, edges rounded 15198224 37.50 Forend dimensions: 28 x 110 mm, for Schüco Firestop 15198128 84.50 Forend dimensions: 20 x 135 mm 15198120 37.50 DORMA TK Reed door contact for monitoring the opening of doors, with 2.3 m flexible connection lead and integrated anti-tamper circuit. NO contact, contact rating: max. 10 W. Kit includes magnet in the same enclosure. Reed door contact for timber doors only, for recessed installation (VdS No. G 151918, Class B), Dimensions (diameter x D) approx.: 6 x 30 mm TK 103 brown 49931103 0.070 25.00 TK 110 white 49931110 0.070 25.00 Reed door contact for timber and metal doors, surface installation (VdS No. 191523, Class B), Dimensions (W x H x D) approx.: 55 x 10 x 10 mm TK 203 brown 49931203 0.080 25.00 TK 210 white 49931210 0.080 25.00 Security Systems 23 Prices subject to change without notice 04/08

Security Systems SAA Control, Monitoring and Alarm Equipment TG panel housing Discontinued product lines In powder-coated light alloy for insertion of TE... panel modules... 4 standard width panel modules Dimensions (W x H x D) approx.: 150 x 90 x 190 mm TG 0420 green (similar to RAL 6001) 56050420 0.600 108.00 TG 0411 white (similar to RAL 9016) 56050411 0.600 108.00... 8 standard width panel modules Dimensions (W x H x D) approx.: 290 x 90 x 190 mm TG 0820 green (similar to RAL 6001) 56050820 0.800 129.00 TG 0811 white (similar to RAL 9016) 56050811 0.800 129.00... 12 standard width panel modules Dimensions (W x H x D) approx.: 430 x 90 x 190 mm TG 1220 green (similar to RAL 6001) 56051220 1.200 143.00 TG 1211 white (similar to RAL 9016) 56051211 1.200 143.00... 16 standard width panel modules Dimensions (W x H x D) approx.: 570 x 90 x 190 mm TG 1620 green (similar to RAL 6001) 56051620 1.700 152.00 TG 1611 white (similar to RAL 9016) 56051611 1.700 152.00 TE 01 dummy module as filler insert Discontinued product lines Light alloy insert, 19 rack-type (3 U high/ 7 HP) Dimensions of face-plate (H x D) approx.: 128 x 35 mm TE 0119 black anodised 56060119 0.270 14.00 TE 02 panel module for single-door monitoring Discontinued product lines Light alloy insert, 19 rack-type (3 U high/ 7 HP), with red and green LEDs for indicating whether door locked or unlocked, and also freely assignable buzzer for audible alarm. Central system activation and de-activation via TE 22/24 (plug-in interconnecting lead supplied as standard). Signal output of 24 V DC convertible to 12 V DC by jumper relocation. For optional connection to RZ emergency exit controls; door terminals with integral TL-S control and connection boards or SVP anti-panic switch-monitored and motor lock. Dimensions of face-plate (H x D) approx.: 128 x 35 mm Current consumption max.: 15 ma per LED 8 ma buzzer TE 0219 black anodised 56060219 0.182 114.00 TE 20 panel module with positive-release emergencyopen push-button for single-door remote de-activation Light alloy module, 19 rack-type (3 U high/ 14 HP, 2x standard width), with red and green LEDs for indicating whether door locked or unlocked, freely assignable buzzer for audible alarm and illuminated red emergency-open push-button according to EN 60947-5-1 with positive-release action. Signal output of 24 V DC convertible to 12 V DC by jumper relocation. For connection to RZ emergency exit controls. Dimensions of face-plate (H x D) approx.: 128 x 70 mm Current consumption max.: 15 ma per LED 8 ma buzzer Emergency pushbutton light 14 ma TE 2019 black anodised 56062019 0.200 238.00 Security Systems 24 Prices subject to change without notice 04/08

Security Systems SAA Control, Monitoring and Alarm Equipment TE 22/24 panel module with lockable system activation and de-activation control Discontinued product lines Light alloy module, 19 rack-type (3 U high/ 14 HP, 2x standard width), with green mushroom button, and prepared for single half cylinder... to switch operating system on and off using key. An additional TE 02 or 32/34 is necessary for activating each door, the interconnecting leads of which are connected in series. Dimensions of face-plate (H x D) approx.: 128 x 70 mm... prepared for single Euro-profile half cylinder to DIN standard 18252 by others, with adjustable locking cam positioned bottom right (max. 45 ) for key withdrawal, total length 40.5-43.5 mm. TE 2219 black anodised 56062219 0.352 195.00 TE 32/34 panel module for single-door monitoring and key switch control Discontinued product lines Light alloy module, 19 rack-type (3 U high/ 14 HP, 2x standard width), with red and green LEDs for indicating whether door locked or unlocked, freely assignable buzzer for audible alarm and prepared for single half cylinder... for system control. Central system activation and de-activation via TE 22/24 (plug-in interconnecting lead supplied as standard). Signal output of 24 V DC convertible to 12 V DC by jumper relocation. Dimensions of face-plate (H x D) approx.: 128 x 70 mm Current consumption max.: 15 ma per LED 8 ma buzzer For optional connection to RZ emergency exit controls; or to door terminals with integral TL-S control and connection boards; or to SVP switch-monitored or motor anti-panic/emergency escape locks.... prepared for single Euro-profile half cylinder to DIN standard 18252 by others, with adjustable locking cam positioned bottom right (max. 45 ) for key withdrawal, total length 40.5-43.5 mm. TE 3219 black anodised 56063219 0.260 187.00 ST key switch of anti-tamper design with LED display Light alloy housing with face plate, suitable for surface and concealed installation, for activating and de-activating the door system from the outside... Dimensions (W x H x D) approx.: Housing: 75 x 75 x 67 mm Face plate (concealed installation): 90 x 100 x 2 mm. For optional connection to RZ emergency exit controls; or to door terminals with integral TL-S control and connection boards. prepared for single Euro-profile half cylinder to DIN standard 18252 by others, with adjustable locking cam positioned bottom right (max. 90 ) for key withdrawal, total length 40.5-43.5 mm.... ST 32 56043201 0.470 120.00 prepared for single round half cylinder of 22 mm dia. (Kaba) by others, with adjustable locking cam positioned bottom right (max.90 ) for key with drawal, total length 40.5-43.5 mm.... ST 34 56043401 0.607 132.00 Security Systems 25 Prices subject to change without notice 04/08

Security Systems SAA Control, Monitoring and Alarm Equipment DORMA BUS control panel TE BUS set BUS operating panel for monitoring and controlling max. 60 emergency exit and escape route doors. Basic system for six doors comprising: Subrack in combined wall/desktop chassis of aluminium; finish: EV1 anodised; for single-row mounting of four modules (1 x BUS basic unit plus 3 x BUS operating modules or 4 x BUS operating modules) with max. width of 84 HP. Excel dimensions (H x W x D): approx. 145 x 440 x 76 mm BUS basic unit with central operating and display for conventional emergency exit control system or TMS; processor-controlled central module with: - buzzer as audible collective fault alarm; - pushbutton for alarm reset; - LED for operating display; - 4 LEDs for status display; - 3 inputs for fire alarm (NC contact), emergency unlocking (NC contact) and external panel disabling contact; - keyswitch for enabling/disabling the operational pushbuttons for controlling the doors; - group functionality; cable recommendation J-Y (st) Y 2 x 2 x 0.8 mm cable approx. 1000 m bus line; 21 HP BUS operating module with operational and display elements for 6 doors, each with: - 3 LEDs (red, green, yellow) for visual door status display; adjustable group function settings for several doors based on a switch block with DIL switches; 21 HP 2-off dummy panels, 21 HP each Integrated power supply unit and interface PCB The BUS control panel is completely assembled in the 19 subrack. All external connections are led out as plug-in/push-lock terminals with screw connection to the interface PCB at the rear of the chassis. Emergency unlocking possible via integrated floating NC contact of a fire alarm system. System enabling possible by integrated emergency pushbutton TL-N S55; only available with TMS and with separate close-current/failsafe loop/wiring of the emergency pushbutton with the TL-S TMS. TE BUS set PZ 56066000 919.00 TE BUS set RZ 56066002 2.935 919.00 Door node hub TMS TE IF-TMS Plug-in TMS door node hub for connecting the BUS cabling to the DORMA TMS door management system. Parallel operation with LON bus cabling and TMS-Soft is not possible. Installation in TL-G or RZ-TMS. TE IF-TMS 56069910 0.050 82.50 Door node hub TL-S 5 TE IF-FWS Conventional door node hub for connecting the BUS cabling to the conventional DORMA emergency exit security and control systems such as the TL-S 5 basic system. All connectors pre-wired ready for plugging into the TL-S 5N. Installation in TL-G. In the case of TL-S 55, with special wiring in RZ 01. TE IF-FWS 56069911 0.050 82.50 Security Systems 26 Prices subject to change without notice 04/08

Security Systems SAA Control, Monitoring and Alarm Equipment BUS Operating Module TE 60 Control BUS With operating and display elements for 6 doors, each with: - 3 LEDs (red, green, yellow) for visual door status indication; - 2 pushbuttons for locking/unlocking and reset (functionality: short-time, longtime, permanent open); including interconnecting cable for connection to a BUS operating module; 21 HP. TE 60 Control BUS 56066001 0.100 207.00 Subrack TG 12 BUS In combined wall and desktop chassis of aluminium, finish: EV1; for single-row mounting of 4 modules (1 x BUS basic unit plus 3 x BUS operating modules or 4 x BUS operating modules); maximum width 84 HP; external dimensions (H x W x D): approx. 145 x 440 x 76 mm. TG 12 BUS 56051210 1.900 155.00 BUS Dummy Panel TE 01 BUS Width 21 HP, with laminated coating TE 01 BUS 56060101 0.075 41.50 DIN 40050 BL 01 green flashing lamp In (similar to RAL 6001) impact-proof, grey ABS housing, with IP class 54 protection according to DIN standard 40 050, for horizontal installation. Approx. 80 flashes/ min., temperature range -20 C to +50 C, operating voltage 24 V DC, 250 ma, rated for 100 % continuous duty. For optional connection to RZ emergency exit controls; or to door terminals with integral TL-S connection and control boards. Dimensions ( x D) approx.: 108 x 133 mm 56070120 0.180 154.00 DIN 40050 AS 01 alarm siren Multi-function alarm siren in impact-proof, white ABS housing, with IP class 65 protection according to DIN standard 40 050. Temperature range -40 C to +80 C, operating voltage 10-28 V DC, rated for 100 % continuous duty, frequency 0.80-2.85 khz, response time 1.5 msec., 105 db. Up to 26 different tones programmable via a 5-pole DIL switch. Incl. AS-Z 01 fixing base for lateral surface cable entry into AS 01 alarm siren. Dimensions (Ø x L) approx.: 92 x 48 mm. For optional connection to RZ emergency exit controls; or to door terminals with integral TL-S control and connection boards. Dimensions ( x L) approx.: 92 x 75 mm Power supply data: 10-28 V DC Current consumption: 8 ma at 12 V DC 18 ma at 24 V DC 56080100 0.570 148.00 Security Systems 27 Prices subject to change without notice 04/08

TMS System overview Door management system as electrical locking system in emergency exit doors as per EltVTR and pren 13637. The door functions are controlled by the TL-S TMS 2 control and interface board or the RZ TMS 2 emergency exit control. Integrated access control function using TMS-Soft / CODIC Card Soft software package. Suitable for connection of various DCW access control reader units. Both controls are designed for connection of max. 4 electronic exit bolts/keeps type TV 1xx DCW`, key switches type ST 3x DCW`, interface PCB TL-S DCW` and other DCW` bus components. Connection to a hazard alert/building control panel (GMA) and/or fire alarm panel (BMA) or a smoke detector for emergency unlocking via a floating contact is possible. DCW` system bus with component auto-identification and default parameterisation of all DCW` system devices. Customised requirements can be programmed into the system via the parameterising software TMS-Soft. System visualisation and control via PC is also possible with the TMS-Soft package. Several TMS can be networked via LON modules and LON gateways or LAN modules. Here, too, parameterisation, visualisation and control are performed via PC and TMS-Soft in the LON or LAN network. Integrated programmable short-time, long-time and permanent unlocking via key-operated momentary-contact switch with parameterisable key actuating times and functions. In the event of a power failure, the system is immediately locked. Following authorised unlocking, re-locking is performed automatically under short-timer control between 3 and 180 seconds, or under long-timer control between 3 and 120 minutes, parameterised via parameterisation software TMS-Soft. Monitoring of the door-open time begins on expiry of the timers. The door open alarm can be triggered after an adjustable time lag of 5 to 180 seconds. The duration of the pre-alarm and main alarm is also programmable. Where automatic re-locking has been activated, once the door has closed, premature re-locking via the door contact can be initiated by programming the system accordingly. Differentiated audible alarms to signal door open time exceeded (pre-alarm and/or main alarm), tamper attempt, system abuse, emergency open and fire alarm with local annunciation and automatic local alarm shutdown after 180 seconds. The functions of the integrated key switch and also those of the external key switches type ST 3x DCW` are adjustable and restrictable. Combination possible with SVP locks, automatic door operators, etc. System TMS Standard TMS Universal TL TMS Universal RZ Special System Component TMS Standard + Psychiatric Institutions Terminal housing TL-G 3xx NT TL-G 3xx TL-UP TL-G 5xx NT TL-G 5xx S55 DCW` Interface PCB TL-S TMS 2 TL-S DCW` integrated TE 20 TL-UP S55 DCW` Control unit integrated RZ TMS Power supply integrated Electromagnetic door locking device TV 1xx DCW` TV 2xx DCW` TV 5xx with DCW`-interface device Key switch ST 32 DCW` TL-ST PZ ST 32 DCW` TL-ST PZ ST 34 DCW` S55 DCW` ST 34 DCW` S55 DCW` Emergency escape lock SVP 5000 Emergency escape lock with monitoring contact SVP 4000 Emergency escape lock with monitoring microswitches SVP 6000 Emergency escape motor lock SVP 2000 Motor lock control SVP-S2x DCW` Accecssories for SVP lock SVP-SB armoured fitting Cable, cable loop SVP-A 1000 KÜ/KS Other Options Access control reader units CODIC Card AS/BL, TG/TE I/O-Modul DCW` LON-Modul, LON-Gateway LAN modules TMS-Soft Security Systems 28

TMS System overview Data and feature System TMS Standard TMS Universal Funktion Opening of door in emergency via emergency pushbutton 3 3 Short-time unlockink, adjustable (3 180 sec) 3 32 3 32 Long-time unlocking 3 120 min 3 32 3 32 Long-time unlocking with audible acknowledge signal 3 3 Permanent unlocking with audible acknowledge signal 3 3 Door open monitoring (1 180 sec) 3 32 3 32 Pre-alarm 3 32 3 32 Main alarm 3 3 Prematurere-locking after door closure 32 2 Lever handle pre-alarm 31 3 32 Differentiated visual and audible status signals 3 3 Bi-directional escape door terminal inside (TL) / TL outside 1 Operation with panel module (TE 20) without local door terminal 1 Automatic re-activation after power failure 3 3 Automatic locking of the emergency escape lock 3 3 Automatic re-activation by emergency escape lock 3 32 3 32 Mechanical sequential control of the emergency escape lock 3 3 Electrical sequential control of the emergency escape lock 1 Emergency unlocking by fire alarm system, building control system, smoke detector, sprinkler system etc. 3 3 Passage from inside to outside via door terminal (TL) 3 3 Passage from outside to inside via key switch (ST) 31 32 1 32 Passage from inside to outside or outside to inside via lock 32 3 Anti-tamber monitoring, TL door terminal 3 3 Anti-tamber monitoring, TV electromagnetic door locking device 3 3 Integrated differential anti-tamper circuit/bus monitoring function 3 3 Alarm duration limit 3 32 3 32 Pre-alarm / Silent alarm 31 3 32 Connection to 230 V AC 3 3 Access control 31 1 Actuation control logic for automatic door operators 31 3 Signal to intruder alarm/intruder alarm disable input 31 2 Connection of external alarm devices 31 3 Remote monitoring, remote control 31 1 Remote unlocking of the emergency escape lock 31 1 3 = Standard 2 = Selectable/programmable 1 = Option = Not available Security Systems 29

TMS TL Door Terminals TL-G 3xx / 5xx NT 230 V Anti-tamper door terminal of powder-coated aluminium alloy, degree of protection IP 40, for accommodation of control and interface board TL-S TMS, with integrated power supply and LED-illuminated red emergency pushbutton as per EN 60947-5-1, positive opening action, and integrated alarm siren with adjustable volume > 100 db. Intensely illuminated emergency pushbutton surround with visual display of the lock status (unlocked = green, locked = red) and visual alarm by yellow flashlight in the event of tamper and operation of the emergency button. Very easy fitting of the terminal top section and bottom section by means of lock cylinders which are accessible from the front, and hinge on upper section. Lockable hinged cover of the emergency pushbutton with anti-tamper contact and transparent lens of non-splinter safety glass. Breakable safety glass with protective film as option. Integrated key switch and momentary contact control mechanism. Power pack: Power supply data: 230 V AC, ± 10% Operating voltage: 24 V DC Current consumption max.: 1 A Temperature range: -20 up to +50 C Dimensions (W x H x D): approx. 90 x 260 x 84 mm... prepared for Europrofile half cylinder accord. to DIN 18252 (locking cam centre 30-32.5 mm, overall length 40.5-43.5 mm), locking cam position bottom right (max. 45 ) TL-G 320 NT green (similar to RAL 6001) Kaste schwarz 56310320 1.800 561.00 TL-G 311 NT white (similar to RAL 9016) Kaste schwarz 56310311 1.780 561.00 TL-G 304 NT stainless steel finish Kaste schwarz 56310304 1.780 666.00 TL-G 399 NT spezial finish Kaste schwarz 56310399 1.780 602.00... prepared for round half cylinder, 22 mm dia., (locking cam centre 30-30.5 mm, overall length 40.5-43.5 mm), locking cam position bottom right (max. 45 ) TL-G 520 NT green (similar to RAL 6001) Kaste schwarz 56310520 1.800 561.00 TL-G 511 NT white (similar to RAL 9016) Kaste schwarz 56310511 1.800 561.00 TL-G 504 NT stainless steel finish Kaste schwarz 56310504 1.800 666.00 TL-G 599 NT spezial finish Kaste schwarz 56310599 1.800 602.00 TL-G 3xx / 5xx Anti-tamper door terminal of powder-coated aluminium alloy, degree of protection IP 40, for receiving the TL-S control and interface boards, with LED-illuminated red emergency pushbutton as per EN 60947-1-1, positive opening action, and integrated alarm siren with adjustable volume > 100 db. High-intensity illuminated emergency pushbutton surround with visual indication of the lock status (unlocked = green, locked = red) and visual alarm by yellow flashing light in the event of tamper of authorised/valid operation of the emergency pushbutton. Very easy fitting of the terminal top section and bottom section by means of lock cylinders accessible from the front, and hinge on upper section. Lockable hinged emergency pushbutton cover with anti-tamper contact and transparent lens of non-splinter safety glass. Breakable safety glass with protective film as option. Integrated key switch and momentary contact control mechanism. Dimensions (W x H x D): approx. 90 x 260 x 84 mm...prepared for Europrofile half cylinder by others to DIN 18252 (locking cam centre 30-32.5 mm, overall length 40.5-43.5 mm), locking cam position bottom right (max. 45º) TL-G 320 green (similar to RAL 6001) 56010320 1.611 345.00 TL-G 311 white (similar to RAL 9016) 56010311 1.644 345.00 TL-G 304 stainless steel finish 56010304 1.619 451.00 TL-G 399 spezial finish (see page 4 for surcharge) 56010399 1.650 380.00...prepared for round half cylinder, 22 mm dia., by others (locking cam centre 30-32.5 mm, overall length 40.5-43.5 mm), locking cam position bottom right (max. 45º) TL-G 520 green (similar to RAL 6001) 56010520 1.650 345.00 TL-G 511 white (similar to RAL 9016) 56010511 1.650 345.00 TL-G 504 stainless steel finish 56010504 1.600 451.00 TL-G 599 spezial finish (see page 4 for surcharge) 56010599 1.650 380.00 Security Systems 30 Prices subject to change without notice 04/08

TMS TL Door Terminals Accessories TL-S TMS 2 Control and interface PCB with integrated dual-port I/O module for installation in TL-G 3xx/5xx TMS and TL-G 3xx/5xx. Two optocoupler inputs (interface connection with signals of 5 30 V AC/DC) for external actuator control. Two floating outputs for activation of external components or other output signals. Integrated short-time, long-time and permanent unlocking via key-operated momentary contact device with programmable and parameterisable key operating times and functions. DCW system bus with automatic device detection and default parameterisation of all DCW system components; customer-specific requirements programmable via configuration software TMS-Soft from Version 4.x. Control, visualisation and parameterisation of all DORMA TMS DCW security systems via customer s PC or mobile PC. Networking effected using the two-wire bus technique (LON FTT 10A). Control, visualisation and parameterisation of up to 1,000 DORMA door management systems (or more) via LON interface and LON adapter card or LAN. Process: LON DORMA Explicit Message. Control and interface PCB designed for connection of max. 4 door locking devices type TV 1xx DCW and keyswitches type ST 3x DCW, plus further DCW bus devices. Suitable for connection of a hazard alert/building control panel (GMA) and/or fire alarm panel (BMA) or smoke detector RM for emergency unlocking via floating contact. Integrated access control function via TMS-Soft/Codic Card Soft. Various DCW compatible access control readers can be connected. Power failure leads to immediate locking. Automatic re-locking after authorised unlocking event adjustable between 3 and 180 seconds via short-time control or between 3 and 120 minutes via configuration software TMS- Soft from Version 4.x. Once the timers have run down, open-time monitors are enabled. Door open alarm can be delayed for between 5 and 180 seconds. Duration of pre-alarm and main alarm programmable. The system can also be programmed to perform premature locking via door contact, with automatic relocking system activated. Differentiated acoustic alarm signals to indicate door open time exceeded (pre and/or main alarm), sabotage, tamper attempt, emergency open and fire alarm with local alarm and automatic local alarm switch-off programmable up to 180 seconds. Configurable alarm and signal loudness volumes. Antitamper bus cabling with sabotage monitoring. Adjustable and definable functions of the integrated keyswitch and also the external keyswitch ST 3 x DCW. Power supply: 24 V DC, ± 10% Current consumption max.: approx. 65 ma approx. 90 ma (emergency mode) Contact rating: 24 V DC, 0.5 A inductive, 1.0 A ohmic Kaste schwarz 56330101 0.080 288.00 TL-S DCW Terminal interface PCB for installation in TL-G 3xx/5xx and connection to control types TL-S TMS 2 or RZ TMS 2 via DORMA system bus DCW. Up to 4 TL-S DCW boards can be connected via the system bus. Adjustable alarm and audible signal volume control; adjustable and definable functions of the integrated keyswitch, with automatic transfer of the TL-S TMS 2 or RZ TMS 2 functions. Power supply: 24 V DC, ± 10% via DCW system bus Current input max.: approx. 65 ma, approx. 85 ma in emergency mode Kaste schwarz 56330201 0.830 87.50 Security Systems 31 Prices subject to change without notice 04/08

055734-01-1-40 DORMA GmbH + Co. KG TMS TL-UP, TL-UP -System 55 Set, TL-N S 55 TL-UP System 55 door terminal Scheibe eindr cken push for emergency Door terminal for installation in standard switch boxes (62 mm deep) to DIN, comprising: emergency pushbutton/controller unit TL-NC S55 and key-operated pushbutton TL-ST PZ S55 for connection to emergency exit control unit RZ TMS 2 or TL-S TMS 2. TL-NC S55 Emergency pushbutton/controller With LED-illuminated, red emergency pushbutton corresponding to EN 60947-5-1, with positive opening action, brightly lit emergency pushbutton surround with optical indicator of the lock status (unlocked = green, locked = red); visual alarm provided by yellow flashing light to signal tamper/sabotage attempts and emergency pushbutton operation; audible alarm via integral alarm siren with parameterisable output volume. Anti-tamper emergency pushbutton cover with glass lens of shatter-proof safety glass. All cover trims from the System 55 switch range and stainless steel unit with adapter frames can be used. TL-NC S55 Emergency pushbutton/controller 56330601 0.110 192.00 System 55 accessories TL-Z N JUNG LS 990 Adapter set for System 55 emergency pushbutton in JUNG LS 990, alpine white. 56399901 40.00 TL-Z N JUNG ES stainless steel Adapter set for System 55 emergency pushbutton in JUNG ES 56399902 40.00 Surface-mounted key switch Keyswitch for emergency exit control, Basic Design and TMS versions. TL-ST PZ S55 prepared for Europrofile single cylinder by others to DIN 18252, (locking cam centre 30 32.5 mm, overall length 40.5 43.5 mm), locking cam position left (90 ) TL-ST PZ S55 W white 56330710 0.130 88.50 TL-ST PZ S55 S silver 56330701 0.133 88.50 TL-ST PZ S55 A anthracite 56330715 0.130 88.50 Frame and accessories see page 41 and 42 TL ST JUNG LS 990 Keyswitch for emergency exit control, Basic Design or TMS type, for integration in JUNG flush-flat switches TL ST JUNG LS 990 alpine white 56330720 93.50 TL ST JUNG stainless steel Keyswitch for emergency exit control, Basic Design or TMS type, for integration in JUNG flush-flat switches TL-ST JUNG ES 56330721 93.50 TL-UP DCW, Feller Edizio design For installation in standard device boxes, comprising: TL-NC emergency pushbutton, keyswitch TL-ST for switching cylinder provided by others (e.g. KABA, 1007F), pre-installed on baseplate with double-unit frame-type trim corresponding to the Feller Edizio due design. TL-UP F21 DCW, door terminal, complete with frame-type trim, white 56330821 298.00 TL-UP F22 DCW, door terminal, complete with frame-type trim, signal green 56330822 298.00 TL-UP F23 DCW, door terminal, complete with frame-type trim, glass/white 56330823 352.00 TL-UP F24 DCW, door terminal, complete with frame-type trim, chrome steel/white 56330824 352.00 TL-UP Fxx DCW : Ordering and supply via DORMA Schweiz AG (DORMA Switzerland) Security Systems 32 Prices subject to change without notice 04/08

055734-01-1-40 DORMA GmbH + Co. KG TMS TL-UP, TL-UP -System 55 Set, TL-N S 55 Scheibe eindr cken push for emergency TL-UP System 55 Set E2 pure white door terminal (DCW emergency pushbutton/controller unit, with key switch, doubleunit frame-type trim, E2 55 white) Door terminal for installation in standard switch boxes (62 mm deep) to DIN, comprising: emergency pushbutton/controller unit TL-NC S55 and key-operated pushbutton TL-ST PZ S55 and double-unit trim S55 E2 in pure white, for connection to emergency exit control unit RZ TMS 2 or TL-S TMS 2, with LED-illuminated, red emergency pushbutton corresponding to EN 60947-5-1, with positive opening action, brightly lit emergency pushbutton surround with optical indicator of the lock status (unlocked = green, locked = red); visual alarm provided by yellow flashing light to signal tamper/sabotage attempts and emergency pushbutton operation; audible alarm via integral alarm siren. Anti-tamper emergency pushbut-ton cover with glass lens of shatter-proof safety glass. 56330110 0.401 292.00 PSU-xx flush-mounting power supply unit Switched power supply unit to EN 60950 for installation in a standard device box for DC power supply to DORMA electric strikes, locks or control units. Power supply: 230 V AC ± 10% 50/60Hz Output voltage: PSU-24 24 V DC Output current: 12 W Dimensions: 51 x 51 x 24 mm (max. diagonal 55 mm) Installation in standard device box (65 mm diameter) PSU-24 56030101 0.110 102.00 TL-UP set, JUNG ES stainless steel door terminal (comprising DCW emergency pushbutton/controller unit, white key switch, double-unit frame-type trim E2 55 white) For installation in standard device boxes (62 mm deep) to DIN, comprising: emergency pushbutton/controller unit TL-NC and keyswitch TL-ST with double-unit frame-type trim, for connection to emergency exit control unit RZ TMS 2 or TL-S TMS 2, with LED-illuminated red emergency pushbutton corresponding to EN 60947-5-1, positive opening action, brightly lit emergency surround with optical indicator of the lock status (unlocked = green; locked = red); visual alarm provided by yellow flashing light to signal tamper/sabotage attempts and emergency pushbutton operation; audible alarm via integral alarm siren. Anti-tamper emergency pushbutton cover with lens of shatter-proof safety glass. Keyswitch type JUNG ES and double-unit frame-type trim type JUNG ES stainless steel 56330115 0.500 361.00 Security Systems 33 Prices subject to change without notice 04/08

TMS RZ TMS 2 RZ TMS 2 emergency exit control In IP 54 plastics enclosure with cover contacts; including DORMA NT-S 24-1.5 power supply PCB, TL-S TMS 2 with integral 2-port I/O module, DCW hub, prepared for installation of motor lock control type DORMA SVP-S 22, LON module, TV DCW coupler and 4-port I/O modules. Emergency power supply via DORMA 230 V AC USV 700 uninterruptible power supply (UPS) module. Designed for connection of up to four TL-G 3xx/5xx DCW or TL-UP S 55, door locking devices type TV 1xx, 2xx, 5xx DCW and key switches type ST 3x DCW, and also other DCW bus devices. Suitable for connection of a hazard alert/building control panel (GMA) and/or fire alarm panel (BMA) or smoke detector type RM for emergency unlocking via floating contact. DCW system bus with automatic device detection and default parameterization of all DCW system components; customer-specific requirements programmable via configuration software TMS Soft from Version 4.x. Integrated access control function with TMS-Soft/CODIC Card Soft. Suitable for connection of various DCW -compatible access control readers. Integrated short-time, long-time and permanent unlocking via key-operated momentary contact device (e.g. TL-G 3xx/5xx DCW, TL-UP S55 or ST keyswitch), programmable with parameterisable key operating times and functions. Power failure leads to immediate locking. Automatic re-locking after authorized unlocking event adjustable between 3 and 180 seconds via short-time control or between 3 and 60 minutes via long-time control freely programmable with configuration software TMS-Soft from Version 4.0. Once the timers have run down, open-time monitors are enabled. Door open alarm can be delayed for between 5 and 180 seconds. Duration of pre-alarm and main alarm programmable. The system can also be programmed to perform premature locking via door contact, with automatic relocking system activated. Differentiated acoustic alarm signals to indicate door open time exceeded (pre and/or main alarm), sabotage, tamper attempt, emergency open and fire alarm, with local alarm and automatic local alarm switchoff after 180 seconds via door terminal. Configurable alarm and signal loudness volumes. Adjustable and definable functions of the integrated key-operated momentary contact device, e.g. TL-G 3xx/ 5xx DCW, TL-UP S55 or ST32 DCW. DORMA I/O module DCW. Integrated input and output modules for connection of conventionally wired products to the DORMA DCW system bus. Four opto-coupler inputs for transmission of external signals and four floating outputs for actuation control of external components or for triggering of signals. Prepared for connection via LON module to DORMA LON bus and standard LON with FTT10A protocol or LAN modules. Power supply: 230 V AC, ±10% Current consumption max.: approx. 85 ma, approx. 105 ma (in emergency mode) Dimensions (W x H x D): approx. 300 x 230 x 85 mm RZ TMS 2 56331100 2.200 643.00 Security Systems 34 Prices subject to change without notice 04/08

N L TMS RZ TMS RZ TMS 2 24 V Emergency exit control unit in enclosure without power supply unit Functions as described in the RZ TMS 2 section, but for connection to DORMA 24 V DC power supply units and emergency power supply units or other power supplies or power supply units to DIN 60950 supplied by others. RZ TMS 2 24 V 56331124 1.100 450.00 RZ TMS NT emergency exit control unit in enclosure with power supply unit NT 1224 N Function as per RZ TMS, but designed for connection to 230 V, prepared for emergency power supply by backup battery pack AP 3034 (not included). Dimensions (W x H x D) approx.: ca. 305 x 380 x 130 mm RZ TMS NT 56331110 9.920 1,158.00 AP 3034 emergency back-up power battery Plug-in connected emergency supply, 30 V / 3.0 Ah for NT 1224, to maintain operation of emergency exit or door security system up to approx. 1 h at max. charge of 12 V, 1 A and 24 V, 1.5 A in the event of power failure or, voltage dip. 56623400 4.692 222.00 RZ-TMS VdS Emergency exit control RZ TMS, Version VdS. Functions as per RZ TMS but, in conjunction with TV 1xx DCW (VdS approval number G105124) or TV 2xx DCW (VdS approval number G105125), approved as pulse blocking element in intruder alarm systems up to Class C. Including CD-ROM with special TMS-Soft 3.0 version and special parameter database. RZ-TMS VdS 56331128 1.100 1,019.00 Security Systems 35 Prices subject to change without notice 04/08

TMS Accessories TV 1xx DCW Electronic exit bolt (fail-safe) with anti-tamper and door monitoring contacts, integrated positive-action monitoring of TV active/inactive states. In corrosion-resistant and tamper-proof metal housing, paint-sprayed. Standard kit includes holder, shim plate set and screw pouch. Max. keeping force according to EltVTR with jam-free release irrespective of loads. Connection to door management system DORMA TMS via DCW system bus. Power supply: 24 V DC, ± 10% Current consumption max.: approx. 250 ma Recommended cable: I-Y(ST) Y4 x 2 x 0.6 Dimensions (W x H x D): approx. 190 x 55 x 80 mm TV 101 DCW silver 56320101 1.520 346.00 TV 103 DCW dark brown 56320103 1.250 346.00 TV 104 DCW stainless steel finish 56320111 1.510 346.00 TV 111 DCW white (similar to RAL 9016) 56320104 1.520 476.00 TV 199 DCW special finish 56320199 1.250 387.00 TV 2xx DCW electro-magnetic door locking device (failsafe principle) Electro-magnet with anti-sabotage/anti-tamper and door monitoring contact, plus integrated positive-action monitoring system for active/inactive status. Housed in anti-corrosion, anti-tamper painted metal enclosure. Magnet mounted on universal (Cardan) joint offering three-dimensional adjustability. Standard package includes anchor plate (also for fire doors) and fixings. Max. holding force per Requirements for electrical locking systems on doors in emergency escape routes (EltVTR) with side-load-immune release. Connection to the DORMA TMS door management system via DCW system bus. Power supply: 24 V DC, ± 10% Current consumption max.: approx. 200 ma Recommended cable: I-Y(ST) Y4 x 2 x 0.6 mm Dimensions (W x H x D): approx. 190 x 55 x 80 mm TV 201 DCW silver 56320201 1.250 398.00 TV 203 DCW dark brown 56320203 1.250 398.00 TV 204 DCW stainless steel finish 56320204 3.170 398.00 TV 211 DCW white (similar to RAL 9016) 56320211 1.250 532.00 TV 299 DCW special finish 56320299 3.270 429.00 TV-Z 01 shim plate set for adjusting holder position in the event of wide fixing tolerances (2 x 1 mm and 1 x 3 mm thick) TV-Z 01 56520101 0.046 7.10 TV-Z 1xx fixing system for flush doors Galvanised steel angle bracket with paint sprayed aluminium cover (prevents access to screws). Dimensions (W x H x D) approx.: 190 x 58 x 84.5 mm... TV-Z 101 silver 56520201 1.070 71.00... TV-Z 103 dark brown 56520203 1.070 80.50... TV-Z 111 white (similar to RAL 9016) 56520211 1.070 80.50... TV-Z 104 stainless steel finish 56520204 1.070 157.00... TV-Z 199 spezial finish (see page 4 for surcharge) 56520299 1.070 87.50 TV DCW adapter DORMA TV DCW adaptor for connection of TV 5xx DCW to DCW system bus. Dimensions (W x H x D): approx. 40 x 40 x 80 mm (housing) TV DCW adapter 56329001 0.200 46.00 Security Systems 36 Prices subject to change without notice 04/08

Emergency Exit Systems Accessories ST 3x DCW Key switch of anti-tamper design with LED display (red/green), silverfinished light alloy housing with face plate, suitable for surface an concealed installation, for activation of the door management system DORMA TMS. Adjustable and definable functionalities of the ST 3x DCW keyswitch can be programmed via the parameterisation software TMS Soft. Connection to door management system DORMA TMS via DCW system bus. Dimensions (W x H x D) - housing: approx. 75 x 75 x 50 mm - frontplate (concealed mounting): 90 x 100 x 2 mm Recommended cabling: 1 4 (ST) Y 2 x 2 x 0.6 mm ST 32 DCW prepared for on-site Europrofile cylinder to DIN standard 18 252 (locking cam centre 30-32.5 mm, overall length 40.5-43.5 mm), locking cam position left (90 ). ST 34 DCW prepared for on-site single round cylinder to DIN standard 18 252 (locking cam centre 30-32.5 mm, overall length 40.5-43.5 mm), locking cam position left (90 ). 56343200 0.520 150.00 56343400 0.607 165.00 I/O Module 4/4 DCW Bus coupling module for connection of products with conventional wiring to the DORMA DCW system bus. Four opto-coupler inputs (interface connection with signals of 5 30 V AC/DC) for external actuation control. Four floating outputs for the activation of external components or for the triggering of signals. Addresses for different requirements are pre-parameterised. Individual requirements can be freely programmed with software TMS Soft (switchon delay, switch-off delay, impulse etc.) Power supply: via DCW bus Current consumption max.: 45 ma Opto-coupler inputs: Uin/nin, 5V/2.8mA, 12 V/8mA, 24 V/17mA, 30 V/28 ma Relay outputs: 24 V DC / 1 A Recommended cabling: 1 4 (ST) Y 2 x 2 x 0.6 mm 56350100 0.085 144.00 DCW junction box DORMA DCW junction box, IP 54, for installation of up to four DCW bus branching modules (hubs) and/or DCW I/O modules. Box dimensions (W x H x D): approx. 200 x 120 x 75 mm DCW VG 56352000 0.700 68.00 DCW bus terminal block DORMA DCW bus terminal block with 6 DCW terminal rows as branching board for DORMA DCW bus participants TV DCW - and TL-NCconnections for insertion into DCW terminal housing or on-site housing. DCW BV 56352100 0.050 40.50 Recommended cabling: 1 4 (ST) Y 2 x 2 x 0.6 mm Security Systems 37 Prices subject to change without notice 04/08

TMS Software Accessories TMS Soft V4 PC software DORMA TMS Soft V4 control, parameterisation and visualisation software for operation with Windows platforms NT, 2000 and XP for configuration of all adjustable functions and parameters via the PC. Control, parameterisation and visualisation of DORMA TMS door management system via RS 232 interface. Control, parameterisation and visualisation of networked DORMA TMS door management systems via DORMA LON bus system for up to 32 doors, or for more than 1,000 doors. The access control feature integrated within the TMS system can be activated using CODIC Card Soft and any DORMA DCW access control reader. System requirements: PC with Pentium processor, min. 512 MB RAM, min. 25 MB free hard disk capacity, colour graphics card, 256-colour screen, min. 800 x 600 pixel resolution, CD-ROM drive, mouse, printer, one free serial interface, extension cable, Windows NT, 2000, XP. Scope of supply: 1 x CD-ROM 1 x TMS-PC adapter for extension cable for upgrade to TMS Soft V2.x, V3.x and V4.x 56339104 0.750 688.00 343.00 TMS OPC server for linking DORMA TMS Soft to building or security management systems that support OPC. The TMS OPC server supports the following OPC (OLE for Process Control) specifications: Data Access V1.0A Data Access V2.05 Data Access V3.0 Alarms and Events Specification 1.10. The OPC server: is implemented as an OutProc-COM service. supports Windows NT 4.0 (from SP6a onwards), Windows 2000 and Windows XP operating systems. A data point with all the status bits, or individual bits as data points, can be stored for each door of a TMS Soft package. An alarm event can also be generated for a data point and individual bits as data points. An alarm event is of simple event type with a value of the data point. Scope of supply: 1 x CD-ROM 56339150 0.449 3,405.00 Security Systems 38 Prices subject to change without notice 04/08

TMS LON Accessories DORMA TMS LON module Module including grounding/earthing conductor for plug-in connection to TL-S TMS, RZ TMS or SVP-S 22 DCW of the DORMA TMS door management system to DORMA LON bus systems. 56353000 0.080 240.00 DORMA TMS LAN-TCP/IP module Module for plug-in connection to TL-S TMS, RZ TMS or SVP-S 22 DCW. The TMS LAN-TCP/IP module enables both TMS control centres and also the PC management system from TMS Soft 5.0 to be interconnected via an Ethernet bus. The PC needs a standard commercial Ethernet card. 56353001 0.200 238.00 DORMA TMS LON USB gateway Gateway for the networking of DORMA door management systems with TMS LON modules, and for connection to PC systems with DORMA TMS-Soft via USB interface. Dimensions (W x H x D): 23 x 18 x 114 mm Scope of supply: 1 pc. USB gateway, 1 pc. driver software disk 56333403 0.450 754.00 DORMA TMS LON gateway 32 Gateway for the networking of up to 32 door management systems with TMS LON modules and for the connection to PC systems with DORMA TMS soft. Dimensions (W x H x D): approx. 120 x 35 x 85 mm Scope of supply: 1 pc. gateway 1 pc. power pack 1 pc. PC connecting cable (zero modem) 1 pc. LON connecting cable 56353100 0.663 1,147.00 TMS LON gateway XXL-PC DORMA TMS LON gateway XXL-PC as PC expansion card for networking more than 1000 DORMA door management systems with TMS LON modules and connection to PC systems with DORMA TMS-Soft. Standard equipment: 1-off XXL-PC gateway as PC expansion card 1-off LON connection cable 1-off driver software CD-ROM 56333200 0.601 1,836.00 PCC-10 Network Adapter TMS LON gateway XXL-PCMCIA DORMA TMS LON gateway XXL-PCMCIA as PCMCIA expansion card for networking more than 1000 DORMA door management systems with TMS LON modules and for connection to mobile PC systems with DORMA TMS-Soft. Not compatible with all notebooks. Hardware list on request. Standard equipment: 1-off XXL gateway as PCMCIA expansion card, 1-off LON connection cable, 1-off driver software CD-ROM 56333300 0.336 2,065.00 LON 1-port repeater FTT LON 1-port repeater with an FTT input and an FTT output for expansion of the LON circuit for an additional 64 nodes and bus lengths > 900 m (BUS). Power supply: 24 V DC Current consumption: max. 60 ma 56333401 0.276 1,147.00 Security Systems 39 Prices subject to change without notice 04/08

TMS LON Accessories LON-10 port repeater FTT LON multiport repeater with one FTT input and 10 FTT outputs for star-connected LON cabling and up to 64 nodes per port. Power supply: 24 V DC Current consumption: max. 60 ma 56333400 0.637 3,154.00 LON LWL-FTT router LON LWL (fibre-optic) router for the implementation of different copper media and transmission rates, e.g. FTT on LWL/fibre optic cabling. Suitable for use in the backbone section over several km. Power supply: 24 V DC Current consumption: max. 60 ma Performance specification: Connector type ST Multimode 62,5 µm / 125 µm; 820 nm 56333500 0.606 3,441.00 I/O module DCW / LON / LAN Bus interface module for connection of devices with analogue switching contacts to the DORMA DCW system bus or suitable for networking via LON modules and LON gateway or LAN modules. Four optocoupler inputs (interface connection with signals of 5-30V AC) for external actuation control. Four floating outputs for activation of external components or other output signals. In the LON/LAN mode, the inputs and outputs can be freely parameterised and adopted in the visualisation system through TMS Soft implementation (V5.x or later). Power supply: via DCW bus or LON / LAN bus Current consumption max.: 45 ma Opto-coupler inputs: Uin, 5V/2.8mA, 12 V/8mA, 24 V/17 ma, 30 V/28 ma Relay outputs: 24 V DC / 1 A 56333451 303.00 LON 8-port I/O module LON bus coupling module for connection of products with analogue switching relays to the DORM LON bus. Eight inputs for transmission of external signals and control commands (floating) and eight floating outputs for activation control of external devices or triggering of signals. Individual requirements can be freely programmed using various LON tools. Power supply: 24 V DC Relay outputs: 230 V AC/10 A 56333450 0.370 1,139.00 LON mark plug-in pathfinder for TMS/SVP 56399101 0.450 15.00 LON Pathfinder Software basic package 1,916.00 Echelon licences, 64 nodes 505.00 Echelon licences, 256 nodes 1,094.00 Echelon licences, 1024 nodes 3,575.00 Security Systems 40 Prices subject to change without notice 04/08

System 55 Trims DORMA System 55 Frame Type Trims (FR = Frame). DORMA Standard 55 frame-type trim consisting of unbreakable, impact-resistant thermoplastic with high UV stability and an easy-care surface. The colour pure white matt silk is similar to RAL 9010. FR-S55 1 Single-unit trim Standard 55 white 56391110 0.100 4.70* FR-S55 2 Double-unit trim Standard 55 white 56391210 0.031 7.10* FR-S55 3 Triple-unit trim Standard 55 white 56391310 0.040 10.50* Special article number for green trims. on enquiry on enquiry DORMA E2 55 frame-type trim The DORMA E2 frame-type trim combines a markedly minimalist design and robust materials. It is available in three colours pure white matt silk, silver and anthracite and is made of unbreakable, UV-resistant plastic with an easy-care surface. FR-E2W 1 Single-unit trim E2 55 white 56392110 0.186 10.50* FR-E2W 2 Double-unit trim E2 55 white 56392210 0.295 14.50* FR-E2W 3 Triple-unit trim E2 55 white 56392310 0.630 18.50 FR-E2W 4 Quad-unit trim E2 55 white 56392410 0.078 23.00 FR-E2A 1 Single-unit trim E2 55 anthracite 56392115 0.020 10.50* FR-E2A 2 Double-unit trim E2 55 anthracite 56392215 0.270 14.50* FR-E2A 3 Triple-unit trim E2 55 anthracite 56392315 0.344 18.50 FR-E2A 4 Quad-unit trim E2 55 anthracite 56392415 0.082 23.00 FR-E2S 1 Single-unit trim E2 55 silver 56392101 0.192 14.50* FR-E2S 2 Double-unit trim E2 55 silver 56392201 0.032 18.50* FR-E2S 3 Triple-unit trim E2 55 silver 56392301 0.344 27.50 FR-E2S 4 Quad-unit trim E2 55 silver 56392401 0.085 34.50 Dummy insert FR-S 55 WB Dummy insert, System 55 white 56398110 0.034 10.50 FR-S 55 SB Dummy insert, System 55 silver 56398101 0.034 14.50 FR-S 55 AB Dummy insert, System 55 anthracite 56398115 0.034 10.50 DORMA ESPRIT 55 frame-type trim The design of the DORMA Esprit frame features clear, straight lines and a combination of carefully selected high-quality materials, including sparkling glass, anodised and satinised E1 and EV1 aluminium, highly polished brass, matt terracotta with a special surface seal and highquality gleaming chrome. The design of the DORMA ESPRIT frame can be customised so as to meet specific project requirements. FR-EspritA 1 Single-unit trim Esprit 55 alu 56393101 0.112 41.00 FR-EspritA 2 Double-unit trim Esprit 55 alu 56393201 0.204 68.50 FR-EspritA 3 Triple-unit trim Esprit 55 alu 56393301 0.283 105.00 FR-EspritB 1 Single-unit trim Esprit 55 brass 56393105 0.257 41.00 FR-EspritB 2 Double-unit trim Esprit 55 brass 56393205 0.412 68.50 FR-EspritB 3 Triple-unit trim Esprit 55 brass 56393305 0.574 105.00 FR-EspritC 1 Single-unit trim Esprit 55 chrome 56393115 0.258 41.00 FR-EspritC 2 Double-unit trim Esprit 55 chrome 56393215 0.410 68.50 FR-EspritC 3 Triple-unit trim Esprit 55 chrome 56393315 0.573 105.00 FR-EspritG 1 Single-unit trim Esprit 55 glass 56393100 0.165 41.00 FR-EspritG 2 Double-unit trim Esprit 55 glass 56393200 0.240 68.50 FR-EspritG 3 Triple-unit trim Esprit 55 glass 56393300 0.254 105.00 FR-EspritS 1 Single-unit trim Esprit 55 special 56393199 0.640 on enquiry FR-EspritS 2 Double-unit trim Esprit 55 special 56393299 0.190 on enquiry FR-EspritS 3 Triple-unit trim Esprit 55 special 56393399 0.340 on enquiry * Minimum purchase quantities (Standard 1/2/3/4-unit + E2 1/2-unit, 10 each) Security Systems 41 Prices subject to change without notice 04/08

System 55 Trims, Design column DORMA System 55 Frame Type Trims (FR = Frame). System 55 accessories TL-Z N JUNG LS 990 Adapter set for System 55 integrated in JUNG LS 990 alpine white 56399901 40.00 TL-Z N JUNG stainless steel Adapter set for System 55 integrated in JUNG ES 56399902 40.00 DORMA TX 44 frame-type trim The DORMA TX 44 frame-type trim is suitable for an extraordinarily broad spectrum of applications. Installed to IP 44 with water protection it can be used in wet rooms and outside areas. However, with reinforced frames, robust materials and anti-theft installation it is also suitable for higher specifications. In addition, with the integration of System 55 units it offers outstandingly comprehensive water protection functions. The transparent hinged covers serve to protect all components that do not already meet IP 44 requirements (e.g. CODIC key reader, key switch etc.). The emergency pushbutton is protected by the FR-TX44 Set 55 gasketing set with black rubber seal. The CODIC CARD keypad reader is also already IP 44 protected. This seal can also be used for all interior applications and protected external areas. FR-TX44W 1 Trim single-unit IP 44 white 56394110 0.066 18.50 FR-TX44W 2 Trim double-unit IP 44 white 56394210 0.094 27.50 FR-TX44W 3 Trim triple-unit IP 44 white 56394310 0.120 46.00 FR-TX44W 4 Trim quad-unit IP 44 white 56394410 0.144 60.00 FR-TX44W KDT Transparent hinged white 56399010 0.030 27.50 FR-TX44S 1 Trim single-unit IP 44 silver 56394101 0.066 18.50 FR-TX44S 2 Trim double-unit IP 44 silver 56394201 0.094 27.50 FR-TX44S 3 Trim triple-unit IP 44 silver 56394301 0.120 46.00 FR-TX44S 4 Trim quad-unit IP 44 silver 56394401 0.144 60.00 FR-TX44S KDT Transparent hinged silver 56399001 0.030 27.50 FR-TX44A 1 Trim single-unit IP 44 anthracite 56394115 0.066 18.50 FR-TX44A 2 Trim double-unit IP 44 anthracite 56394215 0.094 27.50 FR-TX44A 3 Trim triple-unit IP 44 anthracite 56394315 0.120 46.00 FR-TX44A 4 Trim quad-unit IP 44 anthracite 56394415 0.144 60.00 FR-TX44A KDT Transparent hinged anthracite 56399015 0.030 27.50 FR-TX44 Set 55 Sealing set for System 55 components 56399000 0.020 14.50 Dummy inserts FR-TX44 WB Dummy insert TX 44 white 56398210 0.020 21.00 FR-TX44 WS Dummy insert TX 44 silver 56398201 0.020 21.00 FR-TX44 WA Dummy insert TX 44 anthracite 56398215 0.020 21.00 DORMA Design column 1.4 m incl. TX 44 quad-unit frame for the integration of System 55 components. The DORMA Design column can be fitted with components as required, has IP 44 water protection and is available in pure white, anthracite and silver. Any of the features from the water-protected TX 44 range of switches can also be fitted in its empty units. The FR-TX44 Set 55 gasketing set or FR-TX 44 KDT transparent hinged covers are required as accessories to achieve protection class IP 44 for System 55 components. "Design" column 1.4 m incl. TX44 quad-unit trim pure white 56395010 10.800 582.00 "Design" column 1.4 m incl. TX44 quad-unit trim silver 56395001 11.000 676.00 "Design" column 1.4 m incl. TX44 quad-unit trim anthracite 56395015 10.800 617.00 Security Systems 42 Prices subject to change without notice 04/08

Emergency Escape Lock SVP 6000 Emergency escape lock with automatic locking action SVP 6000 Field of application The SVP 6000 emergency escape lock with automatic locking action is particularly suitable for use in access-controlled doors that also serve as emergency exits or must satisfy emergency escape requirements. Function Mechanical locking is now a thing of the past. With this system, the door is automatically relocked on closure. Manual unlocking through operation of the lever handle on the inside (emergency escape/panic function) or by electrically engaged external lever handle. Alternatively by key from the outside. Special features Also available as fail-safe unit and as access control lock SVZ 6000 without emergency escape function. Item Product Order No. /ea. Qty 1 SVP 6xxx, fail-secure, 24 V DC, emergency escape lock with microswitch monitoring and automatic locking action, with split follower e.g.: SVP 6710 A 24 V DC 15671001 416.00 2 SVP-A connection cable e.g.: SVP-A 1000 49932990 42.50 3 KÜ cable loop, reinforced spiral e.g.: KÜ 480 15813000 41.50 4 RZ-01 stabilised power supply unit, 24 V DC 56030100 147.00 Options 5 SVP-SB 711 anti-tamper/security fitting 49961101 135.00 6 EST sensor for intruder alarm systems 19751104 128.00 7 CODIC MasterCard CMC Hxx access control e.g.: CMC-H10, white 19350110 372.00 8 System 55 cover frame (FR = Frame) e.g.: FR-S55 1, single aperture frame, Standard 55, white 56391110 4.70 9 CODIC CARD transponder fob CTH-03 CTH-03, pack of 10 fobs 19175003 108.00 RZ-01 230 VAC KÜ SVP 6000 SVP-A Security Systems 43 Prices subject to change without notice 04/08

Emergency Escape Lock SVP 2000 Emergency escape motor lock SVP 2000 Field of application The SVP 2000 motor lock is particularly suited to automated and/or accesscontrolled doors in emergency exits or doors subject to emergency escape requirements. Function Manual locking and unlocking is a thing of the past. Unlocking is performed under motorised power, actuated manually through lever handle operation from the inside or by key from the outside. The door re-locks automatically on closure. Special features Exceptional anti-tamper protection. Mechanical and electronic positive sequential control function for reliable fail-secure operation. Power failure protection. Flexible parameterisation by PC and Palm; LON-compatible. When using SVP 2000 motor locks in fire and smoke check doors, the control system must be isolated and made dead by an officially approved fire/smoke detector! Item Product Order No. /ea. Qty 1 SVP 2xxx, emergency escape motor lock with automatic locking action e.g.: SVP 2719 49271915 587.00 2 SVP-S motor lock control as electronic control PCB for operation of SVP 2000 emergency escape motor locks SVP-S 24 DCW 15922402 419.00 3 SVP-A connection cable e.g.: SVP-A 1000 49932990 42.50 4 KÜ cable loop, reinforced spiral e.g.: KÜ 480 15813000 41.50 5 TK reed door contact e.g.: TK 210, white 49931210 25.00 Options 2A SVP-S motor lock control as electronic control PCB for operation of SVP 2000 emergency escape motor locks SVP-S 25 DCW with lockable enclosure 15922502 454.00 6 SVP-SB 710 anti-tamper/security fitting 49961001 135.00 7 EST sensor for intruder alarm systems 19751104 128.00 8 RM smoke detector for use on fire doors 64810001 256.00 9 SVP-PR 12 power reserve module 15922601 67.00 10 CODIC MasterCard CMC-Hxx access control e.g.: CMC-H10, white 19350110 372.00 11 System 55 trim frame (FR = Frame) e.g.: FR-S55 1, single aperture frame, Standard 55, white 56391110 4.70 12 CODIC CARD transponder fob CTH-03 CTH-03, pack of 10 fobs 19175003 108.00 SVP-S 230 VAC TK KÜ SVP 2000 SVP-A Security Systems 44 Prices subject to change without notice 04/08

SVZ 6000 Emergency Escape Lock with Automatic Locking Action F SVZ 6xxx Access control lock with automatic locking action, electrically monitored, with single-piece lever handle follower, electrically activated lever handle in fail-secure or fail-safe design, and with mechanical failsafe sequential control. Duisburg function compatible with all electronic and free-turning cylinders. With micro-switches for detection of "locked" (> 90 %), "unlocked" (< 10 % of the deadbolt shoot), "door open/closed" via trip latch, and also "lever handle operation". The lever handles are disengaged (fail-secure) and engaged (fail-safe) in de-energised condition. Actuation of the solenoid in the lock (e.g. by an access control system) engages or disengages the lever handles. Activation for engaging the lever handle is effected via a GND contact and a floating NO contact (failsecure) or NC contact (fail-safe). Permanent open (permanent engagement of the lever handles, e.g. for daytime operation) is possible. Power supply: 12 V DC, or 24 V DC, stabilised, Current consumption max.: 0.4 A, or 0.2 A, Contact rating: max. 30 V DC, 1.5 W Two-point locking activated by preloaded spring after door closes. Three-stage deadbolt safeguard mechanism. Universal trip latch (24 mm forend versions non-handed). Unlocking from outside via key or coupled lever handle. Steel bolt projection 20 mm. 9 mm single-piece square-section follower. Corrosion-protected case of standard (DIN) dimensions, forend and strike plate (included in scope of supply) all in stainless steel... 10 = fail-secure 12 V DC.. 11 = fail-secure 24 V DC.. 60 = fail-safe 12 V DC.. 61 = fail-safe 24 V DC SVZ 6251 backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door 156251.. 1.000 416.00 SVZ 6252 backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door 156252.. 1.000 416.00 DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. SVZ 6261 backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door 156261.. 1.000 416.00 SVZ 6262 backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door 156262.. 1.000 416.00 SVZ 6271 backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door 156271.. 1.000 416.00 SVZ 6272 backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door 156272.. 1.000 416.00 SVZ 6257 / 6258 pierced for Europrofile cylinder, follower-to-keyway centres 72 mm, backset 55 mm, forend 235 x 24 mm and standard strike plate for DIN- L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening. 156257.. 1.100 416.00 SVZ 6267 / 6268 pierced for Europrofile cylinder, follower-to-keyway centres 72 mm, backset 60 mm, forend 235 x 24 mm and standard strike plate for DIN- L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening. 156267.. 1.130 416.00 Security Systems 45 Prices subject to change without notice 04/08

SVZ 6000 Emergency Escape Lock with Automatic Locking Action F.. 10 = fail-secure 12 V DC.. 11 = fail-secure 24 V DC.. 60 = fail-safe 12 V DC.. 61 = fail-safe 24 V DC SVZ 6277 / 6278 pierced for Europrofile cylinder, follower-to-keyway centres 72 mm, backset 65 mm, forend 235 x 24 mm and standard strike plate for DIN- L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening. 156277.. 1.200 416.00 SVZ 6719 pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 35 mm, lock case depth 15.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 narrow-stile door, inward opening, and DIN-R/RH/ISO 5 narrow-stile door, outward opening. 156719.. 1.050 416.00 DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. SVZ 6739 pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 45 mm, lock case depth 15.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 narrow-stile door, inward opening, and DIN-R/RH/ISO 5 narrow-stile door, outward opening. 156739.. 1.140 416.00 SVZ 6361... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door 156361.. 1.000 424.00 SVZ 6362... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door 156362.. 1.000 424.00 SVZ 6371... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door 156371.. 1.000 424.00 SVZ 6372... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door 156372.. 1.000 424.00 SVZ 6367 / 6368 pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening. 156367.. 1.127 424.00 DIN 18251 DIN 18250 DIN EN 12209 SVZ 6377 / 6378 pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening. 156377.. 1.150 424.00 SVZ 6819 pierced for round cylinder, follower-to-keyway centres 94 mm, backset 35 mm, lock case depth 15.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 narrow-stile door, inward opening, and DIN-R/RH/ISO 5 narrow-stile door, outward opening. 156819.. 1.000 424.00 SVZ 6839 pierced for round cylinder, follower-to-keyway centres 94 mm, backset 45 mm, lock case depth 15.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 narrow-stile door, inward opening, and DIN-R/RH/ISO 5 narrow-stile door, outward opening. 156839.. 1.000 424.00 Requisite accessories to be ordered separately: connecting cable SVP-A Page 63 cable loops KÜ /KS Page 63 power supply unit PSU-24 Page 19, 21 Special strike plate for Schüco RS 65/70 SVP-Z Page 63 Security Systems 46 Prices subject to change without notice 04/08

SVP 6000 Fail secure DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. Emergency Escape Lock with Automatic Locking Action F SVP 6xxx, fail-secure model Emergency escape lock with automatic locking action, electrically monitored, with split lever handle follower, electrically enabled external lever handle of fail-secure design, and mechanical sequential control. Duisburg function compatible with all electronic and free-turning cylinders. With micro-switches for detection of the locked (> 90%), unlocked (< 10% of deadbolt throw), door open/closed via trip latch, and also lever handle/emergency or panic escape unlocking. Switching point for lever handle/emergency unlocking ahead of unlocked/locked signal. The external lever handle is disengaged in the de-energised condition (fail-secure).in the de-energized condition, the external lever handle is disengaged. Actuation of the solenoid in the lock (e.g. by an access control system) engages the external lever handle and thus enables the lock to be operated. The lever handle in the emergency direction is always engaged. Activation for engaging the external lever handle is effected via a GND contact and a floating (no-volt) NO contact. Permanent open (permanent engagement of the external lever handle, e.g. for daytime operation) is possible as long as the contact remains closed (fail-secure principle). Power supply data: 12 V DC, stabilised; Current consumption max.: 0.4 ma; Contact rating: 24 V DC, 125 ma, 1.5 W. Two-point locking activated by preloaded spring after door closes. Three-stage deadbolt safeguard mechanism. Universal trip latch (24 mm forend type, non-handed). Unlocking from the outside via key or enabled external lever handle. Steel bolt projection 20 mm. 9 mm split square-section follower. Corrosion-protected steel lock case in DIN dimensions, forend and strike plate of stainless steel included in scope of supply. SVP 6251 A backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, outward opening SVP 6252 A backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, outward opening SVP 6253 A backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, inward opening SVP 6254 A backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, inward opening SVP 6255 / 6258 A backset 55 mm, forend 235 x 24 mm, standard strike plate for DIN- L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening SVP 6256 / 6257 A backset 55 mm, forend 235 x 24 mm, standard strike plate for DIN- R/RH/ISO 5 flush-closing door, inward opening, and DIN-L/LH/ISO 6 flush-closing door, outward opening Order No.:... 00 = 12 VDC Order No.:... 01 = 24 VDC 156251.. 1.000 416.00 156252.. 1.000 416.00 156253.. 1.000 416.00 156254.. 1.000 416.00 156258.. 1.100 416.00 156257.. 1.100 416.00 Other versions, e.g. 24 V DC; special forend on application Security Systems 47 Prices subject to change without notice 04/08

SVP 6000 Fail secure DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. Emergency Escape Lock with Automatic Locking Action F SVP 6261 A backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, outward opening SVP 6262 A backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, outward opening SVP 6263 A backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, inward opening SVP 6264 A backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, inward opening SVP 6265 / 6268 A backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening SVP 6266 / 6267 A backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-R/RH/ISO 5 flush-closing door, inward opening, and DIN-L/LH/ISO 6 flush-closing door, outward opening SVP 6271 A backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, outward opening SVP 6272 A backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, outward opening SVP 6273 A backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, inward opening SVP 6274 A backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, inward opening SVP 6275 / 6278 A backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening SVP 6276 / 6277 A backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-R/RH/ISO 5 flush-closing door, inward opening, and DIN-L/LH/ISO 6 flush-closing door, outward opening Order No.:... 00 = 12 VDC Order No.:... 01 = 24 VDC 156261.. 1.000 416.00 156262.. 1.000 416.00 156263.. 1.050 416.00 156264.. 1.050 416.00 156268.. 1.130 416.00 156267.. 1.130 416.00 156271.. 1.000 416.00 156272.. 1.000 416.00 156273.. 1.058 416.00 156274.. 1.100 416.00 156278.. 1.200 416.00 156277.. 1.200 416.00 Other versions, e.g. 24 V DC; special forend on application Security Systems 48 Prices subject to change without notice 04/08

SVP 6000 Fail secure DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. Emergency Escape Lock with Automatic Locking Action F SVP 6361 A... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, outward opening SVP 6362 A... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, outward opening SVP 6363 A... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, inward opening SVP 6364 A... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, inward opening SVP 6365 / 6368 A... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening SVP 6366 / 6367 A... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-R/RH/ISO 5 flush-closing door, inward opening, and DIN-L/LH/ISO 6 flush-closing door, outward opening SVP 6371 A... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, outward opening SVP 6372 A... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, outward opening SVP 6373 A... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, inward opening SVP 6374 A... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, inward opening SVP 6375 / 6378 A... pierced for roundcylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening SVP 6376 / 6377 A... pierced for roundcylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-R/RH/ISO 5 flush-closing door, inward opening, and DIN-L/LH/ISO 6 flush-closing door, outward opening Order No.:... 00 = 12 VDC Order No.:... 01 = 24 VDC 156361.. 1.000 424.00 156362.. 1.000 424.00 156363.. 1.150 424.00 156364.. 1.150 424.00 156368.. 1.122 424.00 156367.. 1.122 424.00 156371.. 1.000 424.00 156372.. 1.000 424.00 156373.. 1.150 424.00 156374.. 1.150 424.00 156378.. 1.150 424.00 156377.. 1.150 424.00 Other versions, e.g. 24 V DC; special forend on application Security Systems 49 Prices subject to change without notice 04/08

SVP 6000 Fail secure DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. Emergency Escape Lock with Automatic Locking Action F SVP 6719 A... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, outward opening, and DIN-R/RH/ISO 5 fine-frame door, inward opening SVP 6710 A... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, inward opening, and DIN-R/RH/ISO 5 fine-frame door, outward opening SVP 6739 A... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, outward opening, and DIN-R/RH/ISO 5 fine-frame door, inward opening SVP 6730 A... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, inward opening, and DIN-R/RH/ISO 5 fine-frame door, outward opening SVP 6819 A... pierced for round cylinder, follower-to-keyway centres 94 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, outward opening, and DIN-R/RH/ISO 5 fine-frame door, inward opening SVP 6810 A... pierced for round cylinder, follower-to-keyway centres 94 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, inward opening, and DIN-R/RH/ISO 5 fine-frame door, outward opening SVP 6839 A... pierced for round cylinder, follower-to-keyway centres 94 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, outward opening, and DIN-R/RH/ISO 5 fine-frame door, inward opening SVP 6830 A... pierced for round cylinder, follower-to-keyway centres 94 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, inward opening, and DIN-R/RH/ISO 5 fine-frame door, outward opening Requisite accessories to be ordered separately: connecting cable SVP-A Page 63 cable loops KÜ /KS Page 63 detectors/ strike plates EST/ESS Page 67 power supply unit PSU-24 Page 19, 21 Special strike plate for Schüco RS 65/70 SVP-Z Page 63 Order No.:... 00 = 12 VDC Order No.:... 01 = 24 VDC 156719.. 1.050 416.00 156710.. 1.044 416.00 156739.. 1.140 416.00 156730.. 1.135 416.00 156819.. 1.000 424.00 156810.. 1.150 424.00 156839.. 1.000 424.00 156830.. 1.150 424.00 Other versions, e.g. 24 V DC; special forend on application Security Systems 50 Prices subject to change without notice 04/08

SVP 6000 Fail safe DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. Emergency Escape Lock with Automatic Locking Action F SVP 6xxx, fail-safe model Emergency escape lock with automatic locking action, electrically monitored, with split lever handle follower, electrically enabled external lever handle of fail-safe design, and mechanical sequential control. Duisburg function compatible with all electronic and free-turning cylinders. With micro-switches for detection of the locked (> 90%), unlocked (< 10% of deadbolt throw), door open/closed via trip latch, and also lever handle/emergency or panic escape unlocking. Switching point for lever handle/emergency unlocking ahead of unlocked/locked signal. The external lever handle is engaged in the de-energised condition (failsafe). In the de-energized condition, the external lever handle is engaged. Actuation of the solenoid in the lock (e.g. by an access control system) engages the external lever handle and thus enables the lock to be operated. The lever handle in the emergency direction is always engaged. Activation for engaging the external lever handle is effected via a GND contact and a floating (no-volt) NO contact. Permanent open (permanent engagement of the external lever handle, e.g. for daytime operation) is possible as long as the contact remains closed (fail-secure principle). Power supply data: 12 V DC, stabilised; Current consumption max.: 0.4 ma; Contact rating: 24 V DC, 125 ma, 1.5 W. Two-point locking activated by preloaded spring after door closes. Threestage deadbolt safeguard mechanism. Universal trip latch (24 mm forend type, non-handed). Unlocking from the outside via key or enabled external lever handle. Steel bolt projection 20 mm. 9 mm split squaresection follower. Corrosion-protected steel lock case in DIN dimensions, forend and strike plate of stainless steel included in scope of supply. SVP 6251 R backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, outward opening SVP 6252 R backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, outward opening SVP 6253 R backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, inward opening SVP 6254 R backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, inward opening SVP 6255 / 6258 R backset 55 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening SVP 6256 / 6257 R backset 55 mm, forend 235 x 24 mm, standard strike plate for DIN-R/RH/ISO 5 flush-closing door, inward opening, and DIN-L/LH/ISO 6 flush-closing door, outward opening Order No.:... 50 = 12 VDC Order No.:... 51 = 24 VDC 156251.. 1.000 416.00 156252.. 1.000 416.00 156253.. 1.000 416.00 156254.. 1.000 416.00 156258.. 1.100 416.00 156257.. 1.100 416.00 Other versions, e.g. 24 V DC; special forend on application Security Systems 51 Prices subject to change without notice 04/08

SVP 6000 Fail safe DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. Emergency Escape Lock with Automatic Locking Action F SVP 6261 R backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, outward opening SVP 6262 R backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, outward opening SVP 6263 R backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, inward opening SVP 6264 R backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, inward opening SVP 6265 / 6268 R backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening SVP 6266 / 6267 R backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-R/RH/ISO 5 flush-closing door, inward opening, and DIN-L/LH/ISO 6 flush-closing door, outward opening SVP 6271 R backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, outward opening SVP 6272 R backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, outward opening SVP 6273 R backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, inward opening SVP 6274 R backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, inward opening SVP 6275 / 6278 R backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening SVP 6276 / 6277 R backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-R/RH/ISO 5 flush-closing door, inward opening, and DIN-L/LH/ISO 6 flush-closing door, outward opening Order No.:... 50 = 12 VDC Order No.:... 51 = 24 VDC 156261.. 1.000 416.00 156262.. 1.000 416.00 156263.. 1.050 416.00 156264.. 1.050 416.00 156268.. 1.130 416.00 156267.. 1.130 416.00 156271.. 1.000 416.00 156272.. 1.000 416.00 156273.. 1.058 416.00 156274.. 1.100 416.00 156278.. 1.200 416.00 156277.. 1.200 416.00 Other versions, e.g. 24 V DC; special forend on application Security Systems 52 Prices subject to change without notice 04/08

SVP 6000 Fail safe DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. Emergency Escape Lock with Automatic Locking Action F SVP 6361 R... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, outward opening SVP 6362 R... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, outward opening SVP 6363 R... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, inward opening SVP 6364 R... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, inward opening SVP 6365 / 6368 R... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening SVP 6366 / 6367 R... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-R/RH/ISO 5 flush-closing door, inward opening, and DIN-L/LH/ISO 6 flush-closing door, outward opening SVP 6371 R... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, outward opening SVP 6372 R... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, outward opening SVP 6373 R... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door, inward opening SVP 6374 R... pierced for round cylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door, inward opening SVP 6375 / 6378 R... pierced for roundcylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 flush-closing door, inward opening, and DIN-R/RH/ISO 5 flush-closing door, outward opening SVP 6376 / 6377 R... pierced for roundcylinder, follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-R/RH/ISO 5 flush-closing door, inward opening, and DIN-L/LH/ISO 6 flush-closing door, outward opening Order No.:... 50 = 12 VDC Order No.:... 51 = 24 VDC 156361.. 1.000 424.00 156362.. 1.000 424.00 156363.. 1.150 424.00 156364.. 1.150 424.00 156368.. 1.122 424.00 156367.. 1.127 424.00 156371.. 1.000 424.00 156372.. 1.000 424.00 156373.. 1.150 424.00 156374.. 1.150 424.00 156378.. 1.150 424.00 156377.. 1.150 424.00 Other versions, e.g. 24 V DC; special forend on application Security Systems 53 Prices subject to change without notice 04/08

SVP 6000 Fail safe DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. Emergency Escape Lock with Automatic Locking Action F SVP 6719 R... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, outward opening, and DIN-R/RH/ISO 5 fine-frame door, inward opening SVP 6710 R... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, inward opening, and DIN-R/RH/ISO 5 fine-frame door, outward opening SVP 6739 R... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, outward opening, and DIN-R/RH/ISO 5 fine-frame door, inward opening SVP 6730 R... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, inward opening, and DIN-R/RH/ISO 5 fine-frame door, outward opening SVP 6819 R... pierced for round cylinder, follower-to-keyway centres 94 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, outward opening, and DIN-R/RH/ISO 5 fine-frame door, inward opening SVP 6810 R... pierced for round cylinder, follower-to-keyway centres 94 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, inward opening, and DIN-R/RH/ISO 5 fine-frame door, outward opening SVP 6839 R... pierced for round cylinder, follower-to-keyway centres 94 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, outward opening, and DIN-R/RH/ISO 5 fine-frame door, inward opening SVP 6830 R... pierced for round cylinder, follower-to-keyway centres 94 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for DIN-L/LH/ISO 6 fine-frame door, inward opening, and DIN-R/RH/ISO 5 fine-frame door, outward opening Requisite accessories to be ordered separately: connecting cable SVP-A Page 63 cable loops KÜ /KS Page 63 detectors/ strike plates EST/ESS Page 67 power supply unit PSU-24 Page 19, 21 Special strike plate for Schüco RS 65/70 SVP-Z Page 63 Order No.:... 50 = 12 VDC Order No.:... 51 = 24 VDC 156719.. 1.050 416.00 156710.. 1.044 416.00 156739.. 1.140 416.00 156730.. 1.135 416.00 156819.. 1.000 424.00 156810.. 1.150 424.00 156839.. 1.000 424.00 156830.. 1.150 424.00 Other versions, e.g. 24 V DC; special forend on application Security Systems 54 Prices subject to change without notice 04/08

SVP 5000 Emergency Escape Lock with Automatic Locking Action F SVP 5xxx Emergency escape lock with automatic locking action, with mechanical sequential control. Duisburg function compatible with all electronic and free-turning cylinders. Two-point locking activated by preloaded spring after door closes. Three-stage deadbolt safeguard mechanism. Universal trip latch (24 mm forend versions non-handed), emergency escape unlocking via lever handle; night latch for key access from the outside. Steel bolt projection 20 mm. 9 mm square-section follower. Corrosion-protected lock case of DIN dimensions, forend and strike plate of stainless steel included in scope of supply... DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. SVP 5251 backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 5252 backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 5257 / 5258 backset 55 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 5261 backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 5262 backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 5267 / 5268 backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 5271 backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 5272 backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 5277 / 5278 backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 5281 backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 5282 backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door 15525100 0.950 126.00 15525200 0.950 126.00 15525700 1.050 126.00 15526100 1.050 126.00 15526200 1.050 126.00 15526700 1.100 126.00 15527100 1.100 126.00 15527200 1.100 126.00 15527700 1.110 126.00 15528100 1.140 150.00 15528200 1.140 150.00 Security Systems 55 Prices subject to change without notice 04/08

SVP 5000 Emergency Escape Lock with Automatic Locking Action F DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. SVP 5291 backset 100 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 5292 backset 100 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 5361... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 5362... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 5367 / 5368... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 5371... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 5372... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 5377 / 5378... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 5381... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 5382... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 5719... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door SVP 5739... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door SVP 5819... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 94 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door SVP 5839... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 94 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door Other versions, e.g. special forend, on application 15529100 1.241 169.00 15529200 1.140 169.00 15536100 0.974 131.00 15536200 0.970 131.00 15536700 1.077 131.00 15537100 1.100 131.00 15537200 1.001 131.00 15537700 1.210 131.00 15538100 1.200 159.00 15538200 1.200 159.00 15571900 1.021 126.00 15573900 1.116 126.00 15581900 1.000 131.00 15583900 1.116 131.00 Security Systems 56 Prices subject to change without notice 04/08

SVP 4000 Emergency Escape Lock with Automatic Locking Action F DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. SVP 4xxx Electrically monitored emergency escape lock with automatic locking action, with mechanical sequential control. Duisburg function compatible with all electronic and free-turning cylinders. With micro-switches for detection of the locked (> 90%), unlocked (< 10% of deadbolt throw), door open/closed via trip latch, and also lever handle/emergency or panic escape unlocking. Switching point for lever handle/emergency unlocking ahead of unlocked/locked signal. The external lever handle is engaged in the de-energised condition (fail-safe). Contact rating: 12 V DC, 125 ma, 1.5 W. Two-point locking activated by preloaded spring after door closes. Three-stage deadbolt safeguard mechanism. Universal trip latch (24 mm forend version non-handed). Emergency unlocking by lever handle; night latch for key access from the outside. Steel bolt projection 20 mm. 9 mm square-section follower. Corrosion-protected lock case of DIN dimensions, forend and strike plate of stainless steel included in scope of supply... SVP 4251 backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 4252 backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 4257 / 4258 backset 55 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 4261 backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 4262 backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 4267 / 4268 backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 4271 backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 4272 backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 4277 / 4278 backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 4281 backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 4282 backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door 15425100 0.950 221.00 15425200 0.950 221.00 15425700 1.056 221.00 15426100 1.005 221.00 15426200 1.005 221.00 15426700 1.170 221.00 15427100 1.012 221.00 15427200 1.004 221.00 15427700 1.129 221.00 15428100 1.144 246.00 15428200 1.144 246.00 Security Systems 57 Prices subject to change without notice 04/08

SVP 4000 Emergency Escape Lock with Automatic Locking Action F DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. SVP 4291 backset 100 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 4292 backset 100 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 4371... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 4372... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 4377 / 4378... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 4381... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 4382... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 4719... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door SVP 4739... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door SVP 4819... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 94 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door SVP 4839... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 94 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door Requisite accessories to be ordered separately: connecting cable SVP-A Page 63 cable loops KÜ /KS Page 63 detectors/ strike plates EST/ESS Page 67 Special strike plate for Schüco RS 65/70 SVP-Z Page 63 15429100 1.140 266.00 15429200 1.140 266.00 15437100 1.140 228.00 15437200 1.140 228.00 15437800 1.140 228.00 15438100 1.140 252.00 15438200 1.140 252.00 15471900 1.030 221.00 15473900 1.140 221.00 15481900 1.140 228.00 15483900 1.140 228.00 Other versions, e.g. special forend, on application Security Systems 58 Prices subject to change without notice 04/08

SVP 2000 Emergency Escape Motor Lock with Automatic Locking Action F Also available with panic bar to EN 1125. SVP 2xxx with Order Nos. 15xxxx00 on enquiry SVP 2xxx Emergency escape motor lock with automatic locking action, with mechanical and electrical sequential control for operation via external DORMA SVP-S-2x motor lock control. Duisburg function compatible with all electronic and free-turning cylinders. With micro-switches for detection of locked (> 90%), unlocked (< 10% of the deadbolt shoot), door open/closed via trip latch and also lever handle operation/emergency unlocking. Two-point locking activated by preloaded spring after door closes. Three-stage deadbolt safeguard mechanism. Universal trip latch (24 mm forend versions non-handed). Emergency unlocking by lever handle; night latch for key access from the outside. Steel bolt projection 20 mm. 9 mm square-section follower. Corrosion-protected lock case of DIN dimensions, forend and strike plate of stainless steel included in scope of supply... SVP 2251 backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 2252 backset 55 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 2257 / 2258 backset 55 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 or DIN-R/RH/ISO 5 flush-closing door 49225115 1.050 587.00 49225215 1.052 587.00 49225715 1.109 587.00 DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. SVP 2261 backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 2262 backset 60 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 2267 / 2268 backset 60 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 2271 backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 2272 backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 2277 / 2278 backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 2281 backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 2282 backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door 49226115 1.059 587.00 49226215 1.059 587.00 49226715 1.151 587.00 49227115 1.086 587.00 49227215 1.088 587.00 49227715 1.192 587.00 49228115 1.150 612.00 49228215 1.124 612.00 Security Systems 59 Prices subject to change without notice 04/08

SVP 2000 Emergency Escape Motor Lock with Automatic Locking Action F Also available with panic bar to EN 1125. DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. SVP 2291 backset 100 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 2292 backset 100 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 2371... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 2372... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 2377 / 2378... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 65 mm, forend 235 x 24 mm, standard strike plate for DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 flush-closing door SVP 2381... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-L/LH/ISO 6 over-rebated door SVP 2382... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 74 mm, backset 80 mm, forend 235 x 20 mm, flanged strike plate for DIN-R/RH/ISO 5 over-rebated door SVP 2719... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door SVP 2739... pierced for Europrofile cylinder, follower-to-keyway centres 92 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door 49229115 1.410 631.00 49229215 1.400 631.00 49237115 1.088 594.00 49237215 1.086 594.00 49237715 1.195 594.00 49238115 1.220 620.00 49238215 1.230 620.00 49271915 1.108 587.00 49273915 1.330 587.00 DIN 18251 DIN 18250 DIN EN 12209 Compatible with all electronic and free-turning cylinders. SVP 2819... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 94 mm, backset 35 mm, lock case depth 50.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door 49281915 1.108 594.00 SVP 2839... pierced for round cylinder, 22 mm dia., follower-to-keyway centres 94 mm, backset 45 mm, lock case depth 60.5 mm, forend 270 x 24 mm and standard strike plate for both DIN-L/LH/ISO 6 and DIN-R/RH/ISO 5 fine-frame door 49283915 1.440 594.00 Requisite accessories to be ordered separately: Motor lock controls SVP-S 2x Page 61, 62 Power pack PSU-24 (for SVP-S22/23 only) PSU-24 Page 19, 21 Connecting cables SVP-A Page 63 Cable loops KÜ/KS Page 63 Reed door contacts TK Page 23, 63 detectors/ strike plates EST/ESS Page 67 Special strike plate for Schüco RS 65/70 SVP-Z Page 63 Other versions, e.g. special forend, on application Security Systems 60 Prices subject to change without notice 04/08

Emergency Exit Control Systems SVP-S Motor Lock Controls SVP-S motor lock control unit in the form of an electronic control PCB for the operation of DORMA SVP 2000 emergency escape motor locks For maximum anti-tamper protection (automatic locking in the event of a power failure, integration of an external DORMA TK reed door contact in the trip latch function). Adjustable re-locking time via potentiometer (1-15 s), status LEDs for malfunction, attempted sabotage and normal operation; functional parameters selectable via DIL switches; unlocking via pulse signal with floating (no-volt) NO contact; permanent open (shutdown of the automatic locking function e.g. for daytime operation) as long as the contact remains closed. Signals for unlocked, locked, door open/closed, lever handle operation/emergency unlocking available as floating outputs led to terminal strip. Terminal strip removable. Power supply data: 24 V DC, 12 V DC or 12 V AC Peak starting current 1A; closed-circuit current approx. 65 ma Contact rating: 12 V DC, 125 ma, 1.5 W. SVP-S 22 PCB for installation in control panels/switchgear cabinets and DORMA RZ 12 emergency escape control units, and also for replacement/system expansion. PCB dimensions (W x H x D): approx. 100 x 160 x 40 mm SVP-S 23 Installed in plastics enclosure, IP 40.Enclosure dimensions (W x H x D): approx. 190 x 110 x 60 mm SVP-S 24 Installed in plastics enclosure, IP 54, with RZ-S 01 power supply unit.power supply data: 230 V AC ± 10% Enclosure dimensions (W x H x D): approx. 300 x 230 x 85 mm 15922200 0.393 366.00 15922300 0.639 415.00 15922400 1.130 525.00 SVP-S 25 Installed in lockable sheet steel enclosure (Europrofile half cylinder by others), IP 40, with IRS power supply unit, 12 V AC. Power supply data: 230 V AC ± 10% Dimensions of enclosure (W x H x D): approx. 305 x 380 x 115 mm 15922500 5.800 612.00 Note: Door contact TK 1xx or TK 2xx necessary. Note: The permanent open motor lock function may not be used with fire or smoke check doors as door latching is not guaranteed in the event of fire. When using SVP 2000 motor locks in fire and smoke check doors, the control system must be isolated and made dead by an officially approved fire/smoke detector! Security Systems 61 Prices subject to change without notice 04/08

X7 2 2 2 2 Emergency Exit Control Systems SVP-S Motor Lock Controls. SVP-S 2x DCW LON Motor lock control unit for SVP 2xxx motor locks. DORMA SVP-S 2x DCW motor lock control unit for the operation of SVP 2000 emergency escape motor locks and for connection of SVP 4000 and SVP 6000 locks to DCW and LON networks. Freely parameterisable relocking time via TMS-Soft parameterisation software and integrated RS 232 interface. Re-locking time (2-255 seconds), integrated twelve-month time switch, 3 non-floating inputs for activation control, and two floating relay outputs, freely programmable via integrated RS 232 interface. Unlocking or permanent open (shutdown of the automatic locking function e.g. for daytime operation), via optocoupler inputs. Two freely selectable floating signals available for picking from relay outputs to indicate "locked", "unlocked", "door open/closed" and "lever handle operation/emergency unlocking". Power supply: 12/24 V DC or 12 V Peak inrush current 1 A, closed-circuit current approx. 65 ma, Contact rating: 24 V DC, 0.5 A inductive, 1.0 A ohmic Dimensions of PCB (W x H x D): approx. 75 x 79 x 15 mm. SVP-S 22 DCW Supplied for installation in control cabinets and DORMA RZ TMS emergency exit controls and as replacement/expansion card. 15922202 0.120 291.00 0 1 SVP-S 23 DCW supplied as PCB installed in IP 40 plastics housing. External dimensions of housing (W x H x D): approx. 200 x 120 x 90 mm 15922302 0.848 338.00 0 1 SVP-S 24 DCW installed in IP 54 plastics housings with DORMA NT 24-1.5 S power supply unit. Power supply data: 230 V AC ± 10%, housing external dimensions (W x H x D): approx. 200 x 120 x 90 mm 15922402 1.004 419.00 0 1 SVP-S 25 DCW installed in lockable IP 54 plastics housing with DORMA NT 24-1.5 S power supply unit. Power supply data: 230 V AC ± 10%, housing external dimensions (W x H x D): approx. 200 x 120 x 90 mm 15922502 454.00 SVP-PR 12 Power reserve module Expansion power backup module for ensuring automatic relocking in the event of power failure, compulsory in applications involving fire and smoke check doors. 15922601 0.154 67.00 Note: Door contact TK 1xx or TK 2xx necessary. Note: The permanent open motor lock function may not be used with fire or smoke check doors as door latching is not guaranteed in the event of fire. When using SVP 2000 motor locks in fire and smoke check doors, the control system must be isolated and made dead by an officially approved fire/smoke detector! Security Systems 62 Prices subject to change without notice 04/08

Emergency Exit Control Systems Accessories SVP, KÜ, KS, TK Special strike plate SVP-Z xxx Special strike plate for Schüco RS 65 SVP-Z 065 49940065 0.570 45.00 Special strike plate for Schüco RS 70 SVP-Z 070 49940070 0.640 45.00 Special strike plate for narrow-stile doors per customer specifications SVP-Z 099 49940099 on enquiry SVP-A connecting cables Highly flexible, 12 core, fitted at one end with plug connector to ensure correct electrical mating with SVP 6xxx, 4xxx, 3xxx and 2xxx anti-panic switch-monitored and motor locks. SVP-A 1000 Length = 10 m, 6.5 mm dia 49932990 0.581 42.50 KÜ concealed cable loops Robust spiral metal sheath with recess box to receive flexible connecting cables up to 7.5 mm in diameter. Guarantees a nip-free and anti-tamper protection between leaf and frame of doors. KÜ 260 for door hinges with a pivot offset of up to 18 mm and opening angles up to 110, flexible length of spiral sheath: 155 mm, installation dimensions of recess box (W x H x D) approx.: 24 x 260 x 17 mm. KÜ 480 for door hinges with a pivot offset of up to 36 mm and opening angles up to 180, flexible length of spiral sheath: 370 mm, installation dimensions of recess box (W x H x D) approx.: 24 x 480 x 17 mm. Graded price on enquiry 15811000 0.202 23.50 15813000 0.350 41.50 KS cable loops To receive flexible cables up to 7.5 mm in diameter between moving components with cavity; also ruitable for surface mounting. KS 155 for door hinges with a pivot offset of up to 18 mm and opening angles up to 110, flexible length of spiral sheath: 155 mm, installation dimensions (W x H x D) approx.: 17 x 255 x 15 mm. KS 370 for door hinges with a pivot offset of up to 36 mm and opening angles up to 180, flexible length of spiral sheath: 370 mm, installation dimensions (W x H x D) approx.: 17 x 470 x 15 mm. Graded price on enquiry 15817000 0.095 18.00 15819000 0.160 23.50 DORMA TK Reed door contact for monitoring the opening of doors, with 2.3 m flexible connection lead and integrated anti-tamper circuit. NO contact, contact rating: max. 10 W. Kit includes magnet in the same enclosure. Reed door contact for timber doors only, for recessed installation (VdS No. G 151918, Class B), Dimensions (diameter x D) approx.: 6 x 30 mm TK 103 brown 49931103 0.070 25.00 TK 110 white 49931110 0.070 25.00 Reed door contact for timber and metal doors, surface installation (VdS No. 191523, Class B), Dimensions (W x H x D) approx.: 55 x 10 x 10 mm TK 203 brown 49931203 0.080 25.00 TK 210 white 49931210 0.080 25.00 Security Systems 63 Prices subject to change without notice 04/08

Emergency Escape Locks M-SVP 2000 Multi-point locking system M-SVP 2000 Applications The M-SVP2000 is primarily intended for use in automated entrance doors or entrance doors with access control. Other applications include doors designed for use as emergency exits or fire and smoke check doors. Function Now, manual lock operation has been firmly assigned to the past, replaced by motorised unlocking initiated by operation of the lever handle from the inside or by a key used externally. Automatic motorised re-locking following door closure. Permanent-open with latch retention or day latch. Special feature Exceptional anti-tamper protection, intrusion resistance up to Class 4 in suitable door systems. Connection of external access control systems. Profile-specific kits for steel and aluminium door sections and also timber doors. Item Articel Order No. /each Qty 1 Multi-point locking system M-SVP2000 e.g.: M-SVP2000 UU6 15200001 975.00 2 CODIC MasterCard CMC-Hxx e.g.: CMC-H10 white 19350110 372.00 3 System 55 trim (FR = frame) e.g.: FR-S55 1 single-unit frame-type trim, white 56391110 4.70 4 CODIC CARD transponder fob CTH-03 CTH-03, one pack = 10 fobs 19175003 108.00 Options 2A CODIC CARD reader insert, System 55 e.g.: CRH-G10 reader, white 19250410 303.00 2A CODIC CARD access control unit ACU-02 19350011 565.00 2A CODIC CARD power supply board PSU-01 19350002 142.00 2A Interface controller CIC-02 19493202 668.00 2A Null modem cable NMC 19491720 33.50 2A Programming adapter CCC-H01 19250100 567.00 2A CODIC CARD software CC-SOFT CC-SOFT basic software 19650001 402.00 5 HZ inactive leaf locking device e.g.: HZ 43-32 15914303 80.50 6 SVP-SB 710 anti-tamper/security fitting 49961001 135.00 7 TL-G 3xx/5xx door terminal e.g.: TL-G 320 NT green (sim. to RAL 6001) 56310320 561.00 8 TL-S 5N, control and interface board 56030055 134.00 9 TV 1xx electronic bolt/keep (failsafe type) e.g.: TV 101, silver 56021101 349.00 Security Systems 64 Prices subject to change without notice 04/08

M-SVP 2000 Emergency Escape Lock with Automatic Locking Action F DORMA M-SVP 2000 Emergency escape lock with automatic locking action, with pivoting steel bolts, powered locking and unlocking via redundant motor, panic unlocking via lever handle, inputs for short-time, permanent unlocking and dogging function; floating outputs for door open/close and activation of automatic operator; visual and audible indication of the lock status; plunger contacts for cable-less power and data transmission; only for free-turning Europrofile (PZ) or round (RZ) cylinders; integrated magnetic contact. Power supply: 230 V AC Supplied in sets comprising lock, strike rail, cables and cableways, power and data contacts, control unit and power supply unit, including installation instructions and routing drawing. M-SVP 2000 UU6 LH/ISO6 PZ (free-turning) 15200001 4.400 975.00 M-SVP 2000 UU6 RH/ISO5 PZ ( free-turning) 15200002 4.400 975.00 M-SVP 2000 UU6 LH/ISO6 RZ (free-turning) 15200031 4.400 975.00 M-SVP 2000 UU6 RH/ISO5 RZ (free-turning) 15200032 4.400 975.00 For use with the following profile systems: Heroal 82/90 Hueck BSC T30 Schüco Royal S50N Schüco Royal RS65 Schüco Royal S65 Schüco Royal S70 backset 35 mm, follower-to-keyway centres 92 mm, U-flanged forend 6 x 24 mm, U-flanged strike rail 5,5 x 24 mm M-SVP 2000 UU6,7 LH/ISO6 PZ (free-turning) 15200003 4.400 975.00 M-SVP 2000 UU6,7 RH/ISO5 PZ (free-turning) 15200004 4.400 975.00 For use with the following profile systems: Heroal 065 Heroal Serie 090 backset 35 mm, follower-to-keyway centres 92 mm, U-flanged forend 6,7 x 24 mm, U-flanged strike rail 5,5 x 24 mm M-SVP 2000 UF LH/ISO6 PZ (free-turning) 15200005 4.400 975.00 M-SVP 2000 UF RH/ISO5 PZ (free-turning) 15200006 4.400 975.00 M-SVP 2000 UF LH/ISO6 RZ (free-turning) 15200035 4.400 975.00 M-SVP 2000 UF RH/ISO5 RZ (free-turning) 15200036 4.400 975.00 For use with the following profile systems: Heroal 020 Klauke Baureihe 77 backset 35 mm, follower-to-keyway centres 92 mm, U-flanged forend 6 x 24 mm, flat strike rail 3 x 24 mm M-SVP 2000 40 UF LH/ISO6 PZ (free-turning) 15200009 4.400 975.00 M-SVP 2000 40 UF RH/ISO5 PZ (free-turning) 15200010 4.400 975.00 M-SVP 2000 40 UF LH/ISO6 RZ (free-turning) 15200039 4.400 975.00 M-SVP 2000 40 UF RH/ISO5 RZ (free-turning) 15200040 4.400 975.00 backset 40 mm, follower-to-keyway centres 92 mm, U-flanged forend 6 x 24 mm, flat strike rail 3 x 24 mm M-SVP 2000 UF 65/72 LH/ISO6 PZ (free-turning) 15200015 4.400 975.00 M-SVP 2000 UF 65/72 RH/ISO5 PZ (free-turning) 15200016 4.400 975.00 For use in sheet steel doors: Tekla backset 65 mm, follower-to-keyway centres 72 mm, U-flanged forend 6 x 24 mm, flat strike rail 3 x 24 mm M-SVP 2000 UF ST24 LH/ISO6 PZ (free-turning) 15200017 4.400 975.00 M-SVP 2000 UF ST24 RH/ISO5 PZ (free-turning) 15200018 4.400 975.00 For use with the following profile systems: Forster presto Forster fuego light backset 40 mm, follower-to-keyway centres 92 mm, U-flanged forend 6 x 24 mm, locking components 3 x 24 mm Security Systems 65 Prices subject to change without notice 04/08

M-SVP 2000 Emergency Escape Lock with Automatic Locking Action F M-SVP 2000 UF ST29 LH/ISO6 PZ (free-turning) 15200019 4.400 975.00 M-SVP 2000 UF ST29 RH/ISO5 PZ (free-turning) 15200020 4.400 975.00 For use with the following profile systems: Forster therm backset 40 mm, follower-to-keyway centres 92 mm, flat forend 6 x 24 mm, locking components 3 x 29.5 mm M-SVP 2000 FF LH/ISO6 PZ (free-turning) 15200007 4.400 975.00 M-SVP 2000 FF RH/ISO5 PZ (free-turning) 15200008 4.400 975.00 M-SVP 2000 FF LH/ISO6 RZ (free-turning) 15200037 4.400 975.00 M-SVP 2000 FF RH/ISO5 RZ (free-turning) 15200038 4.400 975.00 For use with the following profile systems: Alcoa AA 610 Hueck 1.0 Jansen Janisol T30 Wicona Wicstyle 65 Wicona Wicstyle 65N Wicona Wicstyle 77 backset 35 mm, follower-to-keyway centres 92 mm, flat forend 3 x 24 mm, flat strike rail 3 x 24 mm M-SVP 2000 45 FF LH/ISO6 PZ (free-turning) 15200011 4.400 975.00 M-SVP 2000 45 FF RH/ISO5 PZ (free-turning) 15200012 4.400 975.00 For use with the following profile systems: Wicona Wicstyle 65 Wicona Wicstyle 65N Wicona Wicstyle 77 backset 45 mm, follower-to-keyway centres 92 mm, flat forend 3 x 24 mm, flat strike rail 3 x 24 mm M-SVP 2000 H 55 / 72 LH/ISO6 PZ (free-turning) 15200021 4.400 975.00 M-SVP 2000 H 55 / 72 RH/ISO5 PZ (free-turning) 15200022 4.400 975.00 For use with timber doors, follower-to-keyway centres 72 mm, backset 55 mm, flat forend 20 mm, locking components M-SVP 2000 H 65 / 72 LH/ISO6 PZ (free-turning) 15200023 4.400 975.00 M-SVP 2000 H 65 / 72 RH/ISO5 PZ (free-turning) 15200024 4.400 975.00 For use with timber doors, follower-to-keyway centres 72 mm, backset 65 mm, flat forend 20 mm, locking components M-SVP 2000 H 65 / 74 LH/ISO6 RZ (free-turning) 15200043 4.400 975.00 M-SVP 2000 H 65 / 74 RH/ISO5 RZ (free-turning) 15200044 4.400 975.00 For use with timber doors, follower-to-keyway centres 74 mm, backset 65 mm, flat forend 20 mm, locking components M-SVP 2000 H 55 / 92 LH/ISO6 PZ (free-turning) 15200025 4.400 975.00 M-SVP 2000 H 55 / 92 RH/ISO5 PZ (free-turning) 15200026 4.400 975.00 For use with timber doors, follower-to-keyway centres 92 mm, backset 55 mm, flat forend 20 mm, locking components M-SVP 2000 H 65 / 92 LH/ISO6 PZ (free-turning) 15200027 4.400 975.00 M-SVP 2000 H 65 / 92 RH/ISO5 PZ (free-turning) 15200028 4.400 975.00 For use with timber doors, follower-to-keyway centres 92 mm, backset 65 mm, flat forend 20 mm, locking components Options M-SVP 2000 H strike rail Full-length strike rail, 29 mm, for timber doors, 15 mm centres LH (ISO 6) 15200102 54.00 RH (ISO 5) 15200104 54.00 M-SVP 2000 surface-mounted control unit Control unit in surface housing (W x H x D) 147 x 118 x 52 mm, including 8 m cable, including power supply unit. 15200140 300.00 Security Systems 66 Prices subject to change without notice 04/08

Emergency Exit Control Systems Intruder Detection Systems EST detector for intruder alarm systems Deadbolt switching contact VdS* Class C No. G 101 153 Forced-entry detector for doors VdS* Class C No. G 101 145 Opening detector VdS* Class B No. G 101 540 Intruder detector with integrated door and deadbolt switching contact for false-alarm-free detection and alarm triggering in the event of attempted break-ins or actual break-in, with door and deadbolt position monitoring. Through the combination of the EST detector, an ESS security strike plate, a mechanical ESB at the top of the door and a monitored ESB at the bottom of the door on the pull (hinge) side, it is possible to create an intruder protection and alarm system which complies e.g. with German property insurance (VdS) requirements. Dimensions: 15 x 105 x 20 mm Switching capacity: max. 30 V DC, 100 ma Connecting cable: Length 4 m, 10-conductor, 6.5 mm dia. 19751104 0.380 128.00 ESS stainless steel security strike plate For combination with EST within an intruder security system.non-handed. ESS 104 Standard security strike plate with latch retention 19753104 0.160 35.50 ESS 304 Mounting plate for multi-point locks 19753304 0.060 24.00 ESS 904 Concealed screw-fix retainer set 19753904 0.024 22.00 Security Systems 67 Prices subject to change without notice 04/08

DORMA HZ Automatic Inactive Leaf Locking Device DORMA HZ Automatic inactive leaf locking device DORMA HZ inactive leaf locking devices provide the ideal solution for all double doors, and particularly emergency escape/panic doors featuring automatic emergency escape locks with automatic locking action and/or automatic operators. Just a single operation opens the active leaf via the SVP lock, with the inactive leaf being simultaneously unlocked ready for opening. Approval certification: General building control test certificate under preparation. When used in conjunction with fire and smoke check doors, an integrated system approval is necessary. Data and features HZ 26 HZ 27 HZ 31 HZ 33F HZ 34 HZ 43-32 HZ 43-20 Timber doors 3 3 1 3 3 Metal doors 3 3 3 3 3 Type LH/ISO6 3 3 3 RH/ISO5 3 3 3 Non-handed 3 3 3 3 Top-mounted 3 3 3 3 3 3 3 Bottom-mounted 3 3 3 3 3 3 = yes = no 1 = option available on enquiry Security Systems 68 Prices subject to change without notice 04/08

DORMA HZ Automatic Inactive Leaf Locking Device HZ inactive leaf locking device HZ 26 for metal and timber doors, non-handed with reversible latch, galvanized, for top mounting 15912600 0.390 80.50 HZ 27 for metal doors, non-handed with reversible latch, galvanized, for bottom mounting 15912700 0.420 80.50 HZ 31 for metal and timber doors, galvanized, for top mounting LH/ISO6/bottom mounting RH/ISO5 15913101 0.229 80.50 for top mounting RH/ISO5/bottom mounting LH/ISO6 15913102 0.240 80.50 HZ 33F for metal doors, galvanized, with spring-mounted deadbolt, for top mounting LH/ISO6/bottom mounting RH/ISO5 15913301 0.450 80.50 for top mounting RH/ISO5/bottom mounting LH/ISO6 15913302 80.50 Forend variants for timber doors on enquiry HZ 34 for timber doors, galvanized, for top mounting LH/ISO6/bottom mounting RH/ISO5 15913401 0.450 80.50 for top mounting RH/ISO5/bottom mounting LH/ISO6 15913402 0.450 80.50 HZ 17 Anti-dust floor socket, galvanized, stainless steel spring 15911700 0.100 28.00 Security Systems 69 Prices subject to change without notice 04/08

DORMA HZ Automatic Inactive Leaf Locking Device HZ inactive leaf locking device HZ 43-32 Stainless steel, for timber and profile doors, LH (ISO 6), (version with crank latch, 34 mm backset, bolt dia. 10 mm), including accessories. 15914301 0.604 80.50 HZ 43-32 Stainless steel, for timber and profile doors, RH (ISO 5), (version with crank latch, 34 mm backset, bolt dia. 10 mm), including accessories. 15914302 0.580 80.50 HZ 43-20 Stainless steel, for metal doors, LH (ISO 6), (version with crank latch, 22 mm backset, bolt dia. 10 mm), including accessories. 15914303 0.571 80.50 HZ 43-20 Stainless steel, for metal doors, RH (ISO 5), (version with crank latch, 22 mm backset, bolt dia. 10 mm), including accessories. 15914304 0.570 80.50 HZ 43-32 Stainless steel for timber and profile doors, LH (ISO 6), sold in packs of 30 (Note: price per pack of 30) 15914311 0.440 1,905.00 HZ 43-32 Stainless steel for timber and profile doors, RH (ISO 5), sold in packs of 30 (Note: price per pack of 30) 15914312 0.450 1,905.00 HZ 43-20 Stainless steel for metal doors, LH (ISO 6), sold in packs of 30 (Note: price per pack of 30) 15914313 0.420 1,905.00 HZ 43-20 Stainless steel for metal doors, RH (ISO 5), sold in packs of 30 (Note: price per pack of 30) 15914314 0.420 1,905.00 Requisite accessories HZ 43-32 Guide sleeve, sold in packs of 30 (Note: price per pack of 30) 15914315 1.390 78.50 HZ 43-20 Guide sleeve, sold in packs of 30 (Note: price per pack of 30) 15914316 78.50 HZ 43 Strike plate, sold in packs of 30 (Note: price per pack of 30) 15914317 0.040 78.50 HZ 43 Slide plate, sold in packs of 30 (Note: price per pack of 30) 15914318 57.00 Security Systems 70 Prices subject to change without notice 04/08

Emergency Exit Control Systems SVP-SB Security Door Fittings SVP-SB 210 security door fitting To DIN 18257 ES 1 with cylinder core pull protection for SVP solid leaf locks, approved for fire and emergency exit doors; follower-tokeyway centres 72 mm, door thicknesses 45-54 mm, cylinder projection 9-15 mm, colour F1, long backplate; furniture set with night latch function and with 9 mm spindle. 49951001 1.950 123.00 SVP-SB 211 security door fitting To DIN 18257 ES 1 with cylinder core pull protection for SVP 6000 solid leaf locks, approved for fire and emergency exit doors; followerto-keyway centres 72 mm, door thicknesses 45-54 mm, cylinder projection 9-15 mm, colour F1, long backplate; lever handle furniture set with split spindle. 49951101 1.950 123.00 SVP-SB 710 security door fitting To DIN 18257 ES 1 with cylinder core pull protection for SVP narrow-stile locks, approved for fire and emergency exit doors; follower-to-keyway centres 92 mm, door thicknesses 55-74 mm, cylinder projection 9-15 mm, colour F1, short backplate; furniture set with night latch function and 9 mm spindle. 49961001 1.550 135.00 SVP-SB 711 security door fitting Aligned to DIN 18257 ES 1 with cylinder core pull protection for SVP 6000 narrow-stile locks, approved for fire and emergency exit doors; follower-to-keyway centres 92 mm, door thicknesses 55-74 mm, cylinder projection 9-15 mm, colour F1, short backplate; lever handle furniture set with split spindle. 49961101 1.550 135.00 Accessories for other door thicknesses on application. Security Systems 71 Prices subject to change without notice 04/08

Emergency Exit Control Systems ZM, RMB Smoke detector ZM 201 universal timer expansion module Discontinued product lines Double-Timer module, e.g. for conversion of up to two 12/24 V DC potential levels and for activation of DORMA ED 200 / 300 automatic swing door operators via anti-panic motor locks of the SVP 2xxx / 3xxx series. Time periods, adjustable via potentiometer: Timer I = (K1) 0.5 to 220 sec. Timer II = (K2) 0.1 to 10 sec. Dimensions (W x H x D) approx.: 65 x 100 x 30 mm Connected load values: 12 / 24 V DC automatic matching Current consumption max.: 80 ma (at 12 V DC) 115 ma (at 24 V DC) Contract rating: 24 V DC; 0.5 A inductive 24 V DC; 1.0 A ohmic 56920100 0.140 129.00 ZM 208 DCW Emergency open-time delay module for installation in TL-G or RZ TMS enclosure. 2-stage time delay per pren 13637. 1st stage max. 15 seconds, 2nd stage max. 180 seconds. Activation of the first stage is always initiated by the emergency pushbutton of the TMS door management system. The second timer can be activated by an additional pushbutton connected to the ZM 208 DCW or to the TMS I/O module, and also using the TMS software in the LON network. The DORMA TSD-DCW touchscreen can be configured as a downcounter. 56920801 0.180 97.00 RMB 10 smoke detector German VdS approval code: G 202 039 Finish: pure white Minimum order quantity: 5 units Function: Principle: Discontinued product lines optical smoke detector using LED light beam/optical lens/photo diode Response threshold: per EN 12239 Technical data: Housing dimensions: 110 x 45 mm (Ø x H) Weight (without battery): approx. 120 g Class of protection: IP 42 Power supply: Battery (standard commercial 9V block battery) Current input, standby: approx. 5 ma Power consumption, emergency mode: approx. 5 ma Operating temperature: + 5 C to + 45 C Battery failure signal: at 45 second intervals, 30 days Sensor defective signal: audible + visual Visual display: LED, red Audible alarm: piezo signal emitter, intermittent Volume: approx. 85 db(a) at 3 m Battery life: 4 years typical VdS approval code: G 202 039 Certified: per EU directive, pren ISO 12239 Network capacity: 40 smoke detectors via 2-wire cable Sliding-scale prices available on application 56700110 0.257 42.00 Security Systems 72 Prices subject to change without notice 04/08

Electric strike Serie Basic, Basic-Safe Standard electric strike, Series Basic Standard fail-secure electric strike of symmetrical design with adjustable latch, non-handed, suitable for over-rebated and flush-closing doors (any position), including free-wheeling diode supplied loose for the DC versions. Standard dimensions: 20.5 x 76 x 28 mm RR version dimensions: 20.5 x 84 x 28 mm Basic Standard, 6-12V AC/DC 15117106 0.183 29.00 Basic E With mechanical deactivation, 6-12V AC/DC 15117206 0.183 34.50 Basic A With mechanical holding, 6-12V AC/DC 15117306 0.183 33.50 Basic AE With mechanical holding and mechanical deactivation, 6-12V AC/DC 15117406 0.183 37.50 Basic RR Standard with monitoring contact 15117506 0.183 93.00 Basic E-RR With mechanical de-activation and monitoring contact, 6-12V AC/DC 15117606 0.183 98.00 Basic A-RR With mechanical holding and monitoring contact, 6-12V AC/DC 15117706 0.183 105.00 Basic AE-RR With mechanical holding, mechanical deactivation and monitoring contact, 6-12V AC/DC 15117806 0.183 119.00 Basic Standard, 12V AC 15117111 0.183 33.50 Basic E With mechanical deactivation, 12V AC 15117211 0.183 37.50 Basic A With mechanical holding, 12V AC 15117311 0.183 36.50 Basic AE With mechanical holding and mechanical deactivation, 12V AC 15117411 0.183 40.50 Basic RR Standard with monitoring contact 12V AC 15117511 0.183 97.00 Basic E-RR With mechanical de-activation and monitoring contact,12v AC 15117611 0.183 101.00 Basic A-RR With mechanical holding and monitoring contact, 12V AC 15117711 0.183 107.00 Basic AE-RR With mechanical holding, mechanical deactivation and monitoring contact, 12V AC 15117811 0.183 122.00 Basic Standard, 12V DC 15117112 0.183 39.50 Basic E With mechanical deactivation, 12V DC 15117212 0.183 44.00 Basic A With mechanical holding, 12V DC 15117312 0.183 43.00 Basic AE With mechanical holding and mechanical deactivation, 12V DC 15117412 0.183 46.50 Basic RR Standard with monitoring contact 12V DC 15117512 0.183 104.00 Basic E-RR With mechanical de-activation and monitoring contact, 12V DC 15117612 0.183 108.00 Basic A-RR With mechanical holding and monitoring contact, 12V DC 15117712 0.183 113.00 Basic AE-RR With mechanical holding, mechanical deactivation and monitoring contact, 12V DC 15117812 0.183 123.00 Basic Standard, 24V DC 15117124 0.183 39.50 Basic E With mechanical deactivation, 24V DC 15117224 0.183 44.00 Basic A With mechanical holding, 24V DC 15117324 0.183 43.00 Basic AE With mechanical holding and mechanical deactivation, 24V DC 15117424 0.183 46.50 Basic RR Standard with monitoring contact 24V DC 15117524 0.183 104.00 Basic E-RR With mechanical de-activation and monitoring contact, 24V DC 15117624 0.183 108.00 Basic A-RR With mechanical holding and monitoring contact, 24V DC 15117724 0.183 113.00 Basic AE-RR With mechanical holding, mechanical deactivation and monitoring contact, 24V DC 15117824 0.183 123.00 Basic E With mechanical deactivation, 6-12 V AC/DC, heavy-duty spring 15127206 36.50 Models with integrated Lucky Strike function Basic Standard, Lucky 12-24V DC 15117150 0.183 72.00 Basic RR Standard, with monitoring contact, Lucky 12-24V DC 15117550 0.183 132.00 Basic Easy Adapt Standard, Easy Adapt, Lucky 12-24V DC 15117149 0.223 92.50 Basic RR Easy Adapt Standard, Easy Adapt, monitoring contact, Lucky 12-24V DC 15117549 0.223 152.00 Standard electric strike, Series Basic-Safe Standard fail-safe electric strike of symmetrical design with adjustable latch, non-handed, suitable for over-rebated and flush-closing doors, including free-wheeling diode. Standard dimensions: 20.5 x 76 x 28 mm RR version dimensions: 20.5 x 84 x 28 mm Basic-S Standard, fail-safe, 12V DC 15137112 0.183 74.50 Basic-S RR Standard, fail-safe, monitoring contact, 12V DC 15137512 0.183 141.00 Basic-S Standard, fail-safe, 24V DC 15137124 0.183 74.50 Basic-S RR Standard, fail-safe, monitoring contact, 24V DC 15137524 0.183 141.00 Accessories to be ordered separately: DORMA strike plates in stainless steel (see pages 78-80) Security Systems 73 Prices subject to change without notice 04/08

Electric strike Series Basic-Radius Standard electric strike with radius latch, Series Basic-Radius Standard fail-secure electric strike of symmetrical design with adjustable latch, non-handed, suitable for over-rebated and flush-closing doors (any position), including free-wheeling diode supplied loose for the DC versions. Standard dimensions: 20.5 x 76 x 28 mm RR version dimensions: 20.5 x 84 x 28 mm Basic-R Standard, 6-12V AC/DC 15111106 0.190 32.50 Basic-R E With mechanical deactivation, 6-12V AC/DC 15111206 0.190 37.50 Basic-R A With mechanical holding, 6-12V AC/DC 15111306 0.190 36.50 Basic-R AE With mechanical holding and mechanical deactivation, 6-12V AC/DC 15111406 0.190 40.50 Basic-R RR Standard with monitoring contact 15111506 0.190 97.00 Basic-R E-RR With mechanical deactivation and monitoring contact, 6-12V AC/DC 15111606 0.190 101.00 Basic-R A-RR With mechanical holding and monitoring contact, 6-12V AC/DC 15111706 0.190 108.00 Basic-R AE-RR With mechanical holding, mechanical deactivation and monitoring contact, 6-12V AC/DC 15111806 0.190 123.00 Basic-R Standard, 12V AC 15111111 0.190 36.50 Basic-R E With mechanical deactivation, 12V AC 15111211 0.190 40.50 Basic-R A With mechanical holding, 12V AC 15111311 0.190 39.50 Basic-R AE With mechanical holding and mechanical deactivation, 12V AC 15111411 0.190 44.00 Basic-R RR Standard with monitoring contact 12V AC 15111511 0.190 100.00 Basic-R E-RR With mechanical deactivation and monitoring contact,12v AC 15111611 0.190 105.00 Basic-R A-RR With mechanical holding and monitoring contact, 12V AC 15111711 0.190 110.00 Basic-R AE-RR With mechanical holding, mechanical deactivation and monitoring contact, 12V AC 15111811 0.190 125.00 Basic-R Standard, 12V DC 15111112 0.190 43.00 Basic-R E With mechanical deactivation, 12V DC 15111212 0.190 48.00 Basic-R A With mechanical holding, 12V DC 15111312 0.190 46.50 Basic-R AE With mechanical holding and mechanical deactivation, 12V DC 15111412 0.190 50.00 Basic-R RR Standard with monitoring contact 12V DC 15111512 0.190 107.00 Basic-R E-RR With mechanical deactivation and monitoring contact,12v DC 15111612 0.190 111.00 Basic-R A-RR With mechanical holding and monitoring contact, 12V DC 15111712 0.190 117.00 Basic-R AE-RR With mechanical holding, mechanical deactivation and and monitoring contact, 12V DC 15111812 0.190 126.00 Basic-R Standard, 24V DC 15111124 0.190 43.00 Basic-R E With mechanical deactivation, 24V DC 15111224 0.190 48.00 Basic-R A With mechanical holding, 24V DC 15111324 0.190 46.50 Basic-R AE With mechanical holding and mechanical deactivation, 24V DC 15111424 0.190 50.00 Basic-R RR Standard with monitoring contact 24V DC 15111524 0.190 107.00 Basic-R E-RR With mechanical deactivation and monitoring contact, 24V DC 15111624 0.190 111.00 Basic-R A-RR With mechanical holding and monitoring contact, 24V DC 15111724 0.190 117.00 Basic-R AE-RR With mechanical holding, mechanical deactivation and monitoring contact, 24V DC 15111824 0.190 126.00 Models with integrated Lucky Strike function Basic-R Standard, Lucky 12-24V DC 15111150 0.183 75.00 Basic-R RR Standard, with monitoring contact, Lucky 12-24V DC 15111550 0.183 135.00 Electric strike with radius latch and special bracket, Series Basic-Radius Standard symmetrical electric strike, fail-secure, with adjustable latch, non-handed, suitable for use in any position on over-rebated and flushclosing doors. The electric strike is equipped with a special bracket (models -K30 and -K40 for combination with a latch guide). Standard dimensions: 20.5 x 76 x 28 mm Basic-R E K30 with mechanical deactivation, 6-12 V AC/DC 15110406 0.190 39.50 Basic-R E K40 with mechanical deactivation, 6-12 V AC/DC 15110606 0.190 39.50 Basic-R E K33 with mechanical deactivation, 6-12 V AC/DC 15110506 0.190 43.00 Basic-R E K50 with mechanical deactivation, 6-12 V AC/DC 15110706 39.50 Accessories to be ordered separately: DORMA strike plates in stainless steel (see pages 78-80) Security Systems 74 Prices subject to change without notice 04/08

Electric strike Series Basic-R-Safe Series Basic-S Standard electric strike with radius latch, Series Basic-R-Safe Standard fail-safe electric strike of symmetrical design with adjustable latch, non-handed, suitable for over-rebated and flush-closing doors, including free-wheeling diode. Standard dimensions: 20.5 x 76 x 28 mm RR version dimensions: 20.5 x 84 x 28 mm Basic-R-S Standard, fail-safe, 12V DC 15131112 0.190 75.50 Basic-R-S RR Standard, fail-safe, monitoring contact, 12V DC 15131512 0.190 139.00 Basic-R-S Standard, fail-safe, 24V DC 15131124 0.190 75.50 Basic-R-S RR Standard, fail-safe, monitoring contact, 24V DC 15131524 0.190 139.00 Standard electric strike, Series Basic-Small Standard electric strike of compact design for installation in thermalbreak profiles, fail-secure, with adjustable latch, asymmetrical design, suitable for over-rebated and flush-closing doors, including free-wheeling diode supplied loose for the DC versions. Dimensions: 16.3 x 90 x 28 mm Basic-S L Standard, LH (ISO 6), 6-12V AC/DC 15119106 0.170 33.50 Basic-S LE With mechanical deactivation, LH (ISO 6), 6-12V AC/DC 15119206 0.170 37.50 Basic-S LA With mechanical holding, LH (ISO 6), 6-12V AC/DC 15119306 0.170 36.50 Basic-S LAE With mechanical holding and mechanical deactivation, LH (ISO 6), 6-12V AC/DC 15119406 0.170 40.50 Basic-S R Standard, RH (ISO 5), 6-12V AC/DC 15118106 0.170 33.50 Basic-S RE With mechanical deactivation, RH (ISO 5), 6-12V AC/DC 15118206 0.170 37.50 Basic-S RA With mechanical holding, RH (ISO 5), 6-12V AC/DC 15118306 0.170 36.50 Basic-S RAE With mechanical holding and mechanical deactivation, RH (ISO 5), 6-12V AC/DC 15118406 0.170 40.50 Basic-S L Standard, LH (ISO 6), 12V AC 15119111 0.170 36.50 Basic-S LE With mechanical deactivation, LH (ISO 6), 12V AC 15119211 0.170 40.50 Basic-S LA With mechanical holding, LH (ISO 6), 12V AC 15119311 0.170 39.50 Basic-S LAE With mechanical holding and mechanical deactivation, LH (ISO 6), 12V AC 15119411 0.170 44.00 Basic-S R Standard, RH (ISO 5), 12V AC 15118111 0.170 36.50 Basic-S RE With mechanical deactivation, RH (ISO 5), 12V AC 15118211 0.170 40.50 Basic-S RA With mechanical holding, RH (ISO 5), 12V AC 15118311 0.170 39.50 Basic-S RAE With mechanical holding and mechanical deactivation, RH (ISO 5), 12V AC 15118411 0.170 44.00 Basic-S L Standard, LH (ISO 6), 12V DC 15119112 0.180 38.50 Basic-S LE With mechanical deactivation, LH (ISO 6), 12V DC 15119212 0.180 43.00 Basic-S R Standard, RH (ISO 5), 12V DC 15118112 0.180 38.50 Basic-S RE With mechanical deactivation, RH (ISO 5), 12V DC 15118212 0.180 43.00 Basic-S L Standard, LH (ISO 6), 24V DC 15119124 0.180 38.50 Basic-S LE With mechanical deactivation, LH (ISO 6), 24V DC 15119224 0.180 43.00 Basic-S R Standard, RH (ISO 5), 24V DC 15118124 0.180 38.50 Basic-S RE With mechanical deactivation, RH (ISO 5), 24V DC 15118224 0.180 43.00 Standard electric strike with lip seal, Series Basic-Small-S Narrow-type electric strike of compact design for installation in thermalbreak profiles; fail-secure; with adjustable latch, asymmetrical design, suitable for over-rebated and flush-closing doors, including lip seal for covering the recess in the profile. Dimensions: 16.3 x 90 x 28 mm BasicLS-S Standard, LH (ISO 6), 6-12V, AC/DC 15121106 0.180 38.50 Basic-RS-S Standard, RH (ISO 5), 6-12 V, AC/DC 15120106 0.180 38.50 Basic-LS-SE with mechanical deactivation, LH (ISO 6), 6-12V, AC/DC 15121206 0.180 43.00 Basic-RS-SE with mechanical deactivation, RH (ISO 5), 6-12V, AC/DC 15120206 0.180 43.00 Accessories to be ordered separately: DORMA strike plates in stainless steel (see pages 78-80) Security Systems 75 Prices subject to change without notice 04/08

Electric strike Series Fire 442, 441, 447 Fire-rated electric strike, Series Fire 442 Discontinued product lines Fire-rated electric strike for position-independent use in fire and smoke check doors, fail-secure, with adjustable latch, non-handed, suitable for over-rebated and flush-closing doors, including varistor and free-wheeling diode supplied loose. Dimensions: 20.5 x 69 x 28 mm Fire 442 Fire-rated electric strike, 6-12V AC/DC 15142106 0.205 210.00 Fire 442 Fire-rated electric strike, 12-48V AC/DC 15142112 0.205 210.00 Fire 442 Fire-rated electric strike, 24-48V AC/DC 15142124 0.205 210.00 Fire 442 RR Fire-rated electric strike with monitoring contact, 6-24V AC/DC 15142506 0.205 263.00 Fire 442 RR Fire-rated electric strike with monitoring contact, 12-48V AC/DC 15142512 0.205 263.00 Fire 442 RR Fire-rated electric strike with monitoring contact, 24-48V AC/DC 15142524 0.205 263.00 Fire-rated electric strike, Series Fire 441 Discontinued product lines Fire-rated electric strike for position-independent use in fire and smoke check doors, fail-secure, with adjustable latch, non-handed, suitable for over-rebated and flush-closing doors, including varistor and free-wheeling diode supplied loose. Dimensions: 20.5 x 60 x 28 mm Fire 441 Fire-rated electric strike, 12-48 V AC/DC. Rated for 100% continuous duty up to 24 V 15141112 0.200 224.00 Fire-rated electric strike, Series Fire 447 Fire-rated electric strike for use any position on fire and smoke check doors, fail-secure, with adjustable latch, non-handed, suitable for over-rebated and flush-closing doors, including free-wheeling diode supplied loose. Dimensions: 20.5 x 77 x 28 mm Dimensions RR Version: 20.5 x 85 x 28 mm Fire 447 Fire-rated electric strike, 6-12V AC/DC 15147106 0.200 186.00 Fire 447 RR Fire-rated electric strike with monitoring contact, 6-12V AC/DC 15147506 0.200 237.00 Fire 447 Fire-rated electric strike, 12V AC 15147111 0.200 186.00 Fire 447 RR Fire-rated electric strike with monitoring contact, 12V AC 15147511 0.200 237.00 Fire 447 Fire-rated electric strike, 12V DC 15147112 0.200 186.00 Fire 447 RR Fire-rated electric strike with monitoring contact, 12V DC 15147512 0.200 237.00 Fire 447 Fire-rated electric strike, 24V DC 15147124 0.200 186.00 Fire 447 RR Fire-rated electric strike with monitoring contact, 24V DC 15147524 0.200 237.00 Models with integrated Lucky Strike function Fire 447 Fire, Lucky 12-24V DC 15147150 0.200 210.00 Fire 447 RR Fire-rated, with monitoring contact, Lucky 12-24V DC 15147550 0.200 258.00 Fire 447 Easy Adapt Fire, Easy Adapt, Lucky 12-24V DC 15147149 0.240 231.00 Fire 447 RR Easy Adapt Fire-rated, Easy Adapt, with monitoring contact, Lucky 12-24V DC 15147549 0.240 282.00 Dummy electric strike, series 447 Strike Prep Symmetrical insert to enable subsequent installation of electric strikes. With adjustable latch, non-handed, suitable for over-rebated and flush-closing doors. Dimensions: 76 x 20 x 18.5 mm 15147000 23.50 Accessories to be ordered separately: DORMA strike plates in stainless steel (see pages 78-80) Security Systems 76 Prices subject to change without notice 04/08

Electric strike Smoke Smoke-rated electric strike, Series Smoke Symmetrical electric strike for use in any position in fire and smoke check doors; fail-secure with adjustable latch; non-handed; suitable for over-rebated and flush-closing doors, including free-wheeling diode supplied loose. Dimensions: 20.5 x 76 x 28 mm Dimensions RR Version: 20.5 x 84 x 28 mm Smoke Smoke-rated electric strike, 6-12V AC/DC 15117006 0.195 65.50 Smoke-RR Smoke-rated electric strike with monitoring contact, 6-12V AC/DC 15117906 0.195 136.00 Smoke Smoke-rated electric strike, 12V AC 15117011 0.195 69.00 Smoke-RR Smoke-rated electric strike with monitoring contact, 12V AC 15117911 0.195 139.00 Smoke Smoke-rated electric strike, 12V DC 15117012 0.195 75,50 Smoke-RR Smoke-rated electric strike with monitoring contact, 12V DC 15117912 0.195 145.00 Smoke Smoke-rated electric strike, 24V DC 15117024 0.195 75.50 Smoke-RR Smoke-rated electric strike with monitoring contact, 24V DC 15117924 0.195 145.00 Models with integrated Lucky Strike function Smoke Smoke, Lucky 12-24V DC 15117050 0.183 106.00 Smoke RR Smoke-rated, with monitoring contact, Lucky 12-24V DC 15117950 0.183 172.00 Smoke Easy Adapt Smoke, Easy Adapt, Lucky 12-24V DC 15117049 0.223 127.00 Smoke RR Easy Adapt Smoke-rated, Easy Adapt, with monitoring contact, Lucky 12-24V DC 15117949 0.223 193.00 Accessories to be ordered separately: DORMA strike plates in stainless steel (see pages 78-80) Security Systems 77 Prices subject to change without notice 04/08

Electric strike Accessories Stainless steel strike plates for electric strikes, as flanged or standard flat strike plates. The standard flat strike plates are non-handed. The strike plates are available with offset fixing holes for timber doors or parallel fixing holes for metal doors. WL 25 Flanged strike plate of stainless steel, LH (ISO 6) for combination with DORMA electric strikes, Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447. Dimensions: 25 x 32 x 250 x 3 mm 15171025 0.172 11.00 WL 25-R Flanged strike plate of stainless steel, LH (ISO 6) for combination with DORMA electric strikes, Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447. The edges are rounded with a radius of 10 mm. Dimensions: 25 x 32 x 250 x 3 mm 15171125 0.175 11.00 WR 25 Flanged strike plate of stainless steel, RH (ISO 5) for combination with DORMA electric strikes, Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447. Dimensions: 25 x 32 x 250 x 3 mm 15170025 0.180 11.00 WR 25-R Flanged strike plate of stainless steel, RH (ISO 5) for combination with DORMA electric strikes, Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447. The edges are rounded with a radius of 10 mm. Dimensions: 25 x 32 x 250 x 3 mm 15170125 0.180 11.00 WL 22 Flanged strike plate of stainless steel, LH (ISO 6) for combination with DORMA electric strikes, Series Basic-S. Dimensions: 22 x 32 x 250 x 2.5 mm 15171022 0.170 11.00 WR 22 Flanged strike plate of stainless steel, RH (ISO 5) for combination with DORMA electric strikes, Series Basic-S. Dimensions: 22 x 32 x 250 x 2.5 mm 15170022 0.164 11.00 Security Systems 78 Prices subject to change without notice 04/08

Electric strike Accessories Stainless steel strike plates for electric strikes, as flanged or standard flat strike plates. The standard flat strike plates are non-handed. The strike plates are available with offset fixing holes for timber doors or parallel fixing holes for metal doors FLH24 Standard flat strike plate of stainless steel with offset holes for fixing to timber doors, with recesses for bolt and latch, non-handed, for combination with DORMA electric strikes, Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447. Dimensions: 24 x 250 x 3 mm 15180124 0.103 4.60 FLH24-94 Standard flat strike plate of stainless steel with offset holes for fixing to timber doors, with recesses for bolt and latch, non-handed, for combination with DORMA electric strikes, Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447. Bolt aperture 94 mm. Dimensions: 24 x 250 x 3 mm 15181124 0.100 4.60 FLM24 Standard flat strike plate of stainless steel with parallel holes for fixing to metal doors, with recesses for bolt and latch, non-handed, for combination with DORMA electric strikes, Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447. Dimensions: 24 x 250 x 3 mm 15180224 0.105 4.60 FLM24-94 Standard flat strike plate of stainless steel with parallel holes for fixing to metal doors, with recesses for bolt and latch, non-handed, for combination with DORMA electric strikes, Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447. Bolt aperture 94 mm. Dimensions: 24 x 250 x 3 mm 15181224 0.100 4.60 FL22 Standard flat strike plate of stainless steel with recesses for bolt and latch, non-handed, for combination with DORMA electric strikes, Series Basic-S Dimensions: 22 x 257 x 3 mm 15180022 0.820 4.60 FKH24 Standard flat strike plate of stainless steel with one hole per location for fixing to timber doors, with recess for latch only, non-handed, for combination with DORMA electric strikes, Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447. Dimensions: 24 x 135 x 3 mm 15180324 0.060 4.10 FKM24 Standard flat strike plate of stainless steel with parallel holes for fixing to metal doors, with recess for latch only, non-handed, for combination with DORMA electric strikes, Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447. Dimensions: 24 x 135 x 3 mm 15180424 0.060 4.10 FLM24-RK Stainless steel flat strike plate prepared for installation of DORMA RK bolt monitoring contact. With parallel holes for fixing to metal doors, with recesses for bolt and latch, non-handed, for combination with Series Basic, Basci-Safe, Fire 442, Fire 441, Fire 447 DORMA electric strikes. Dimensions: 24 x 250 x 3 mm 15180724 0.100 6.90 Security Systems 79 Prices subject to change without notice 04/08

Electric strike Accessories FLM25-LAP Discontinued product lines Standard (flat) strike plate of stainless steel with latch guide. The strike plate ensures accurate latch guidance without the need for precision adjustment of the electric strike and strike plate. Tolerances can be compensated for using the adjustable latch of the electric strike. Parallel holes for fixing to metal doors, with recesses for latch and bolt. For combination with DORMA electric strikes of the Series Basic, Basci-Safe, Smoke and Fire 447. Standard equipment includes a matching bracket for the electric strike. Dimensions: 25 (40 incl. latching guard) x 250 x 3 mm LH (ISO 6) 15180940 0.141 32.00 RH (ISO 5) 15180840 0.141 32.00 Easy Adapt electric strike case cover with latch guide For upgrading DORMA electric strikes as latch-guided units. Suitable for electric strikes of the series Basic, Basic-Safe, Smoke and Fire 447 and the functional versions Mechanical deactivation and Monitoring contact. Tolerance compensation using the adjustable latch of the electric strike. Integrated cable conduit for fixing the connection wires to the casing cover with the aid of an adhesive strip included in the pack. Dimensions: approx. 3.6 x 76 x 31.6 mm 15198010 0,038 27.50 FLM25 Easy Adapt Standard (flat) strike plate of stainless steel for combination with Easy Adapt electric strikes. Parallel holes for mounting on metal doors, with recesses for bolt and latch. Non-handed. Dimensions: 25 (40 incl. latching guard) x 250 x 3 mm FLM25-Easy Adapt 15180925 17.50 FLR25 Easy Adapt Standard (flat) strike plate of stainless steel for combination with Easy Adapt electric strikes. Rounded edges for mounting on timber doors, with recesses for latch and bolt. Non-handed. Dimensions: 25 (40 incl. latching guard) x 250 x 3 mm FLR25-Easy Adapt 16500000090 17.50 RK bolt monitoring contact German Association of Property Insurers VDS Class C No. G 193 082 with floating (no-volt) changeover contact for monitoring of the door locking status. Degree of protection: IP68, Connecting cable: 4m LIYY 3 x 0.14 mm 2 Switching capacity: 30 V DC, 200mA Lucky Strike Electronic unit for controlling DC electric strikes. The Lucky Strike unit ensures the reliable functioning of the electric strike at pre-loads of up to 200N. It also restricts noise emissions from the electric strike to the first few seconds after activation. The Lucky Strike unit can be either integrated in the RZ01 power supply unit, in a standard flush-mounting box or in an enclosure by others. Power supply: 12-48 V DC Max. current: 700 ma Dimensions approx: 35 x 35 x 20 mm Switching capacity: 30 V DC, 200mA 15198000 0.120 37.00 15199000 0.050 58.00 Security Systems 80 Prices subject to change without notice 04/08

Electric strike Technical data Technical data: DORMA electric strikes Voltage Current Resistance Duty factor Basic, Basic-R, Smoke, Fire 447 6-12 V 6V AC 0,65 A 6V DC 0,80 A 12V AC 1,35 A 12V DC 1,53 A 6,5 Ω Basic, Basic-R, Smoke, Fire 447 12 V AC 12V AC 0,44 A 18 Ω Basic, Basic-Safe, Basic-R, Basic-R Safe, 12 V DC 12V DC 0,22 A 51 Ω 100% Smoke, Fire 447 Basic, Basic-Safe, Basic-R, Basic-R Safe, 24 V DC 24V DC 0,13 A 170 Ω 100% Smoke, Fire 447 Basic-S 6-12 V 6V AC 0,70 A 6V DC 0,76 A 12V AC 1,40 A 12V DC 1,50 A 7,5 Ω Basic-S 12 V AC 12V AC 0,50 A 16 Ω Basic-S 12 V DC 12V DC 0,40 A 31 Ω 100% Basic-S 24 V DC 24V DC 0,10 A 215 Ω 100% Fire 442 6-24 V 6V AC 0,48 A 100% Parallel connection 6V DC 0,60 A 100% 12V AC 0,96 A < 1 Min. 12V DC 1,20 A 10 Ω < 1 Min. 24V AC 1,92 A 24V DC 2,40 A Fire 442 6-24 V 6V AC 0,12 A 100% Series connection 6V DC 0,15 A 100% 12V AC 0,24 A 100% 12V DC 0,30 A 40 Ω 100% 24V AC 0,48 A < 1 Min. 24V DC 0,60 A < 1 Min. Fire 441, Fire 442 12-48 V 12V AC 0,24 A 100% Parallel connection 12V DC 0,30 A 100% 24V AC 0,48 A < 1 Min. 24V DC 0,60 A 40 Ω < 1 Min. 48V AC 0,96 A 48V DC 1,20 A Fire 441, Fire 442 12-48 V 12V AC 0,06 A 100% Series connection 12V DC 0,08 A 100% 24V AC 0,12 A 100% 24V DC 0,15 A 160 Ω 100% 48V AC 0,24 A < 1 Min. 48V DC 0,30 A < 1 Min. Fire 442 24-48 V 24V AC 0,12 A 100% Parallel connection 24V DC 0,15 A 100% 48V AC 0,24 A 160 Ω < 1 Min. 48V DC 0,30 A < 1 Min. Fire 442 24-48 V 48V AC 0,06 A 100% Series connection 48V DC 0,08 A 640 Ω 100% The data for AC voltage refers to a frequency of 50 Hz. The simple ohmic resistance of the solenoid coil is given. Security Systems 81 Prices subject to change without notice 04/08

Access Control CODIC MasterCard Stand-alone access control system CODIC MasterCard Field of application Ideal for individual or small numbers of doors in private and commercial environments. Function The CODIC MasterCard system offers access control functionality based on proximity ID cards, transponder chips and individual keypad codes. Access rights can be created, edited and deleted, all in a matter of seconds, using the CODIC MasterCard programming card. Special features/benefits Security for both external and internal doors Access authorisation via proximity cards and/or ID codes Minimised security risk in the event of a card being lost Easy programming and simple operation without PC or software Dual security legitimisation possible Various access control options available for flexibility Authorised permanent-open setting option Visual and audible signalling of all operating conditions Optional functional and security expansion via I/O module With anti-tamper and anti-attack alarms as required Simple installation in standard flushmounting box System 55 design matching the switch unit frames of leading manufacturers Impressive value for money Item Product Order No. /ea. Qty 1 CODIC MasterCard CMC-Hxx e.g.: CMC-H10, white 19350110 372.00 2 System 55 cover frame (FR = Frame) e.g.: FR-S55 1, single-aperture frame, Standard 55, white 56391110 4.70 3 CODIC CARD transponder fob CTH-03 CTH-03, pack of 10 fobs 19175003 108.00 4 Electric strike e.g.: 117 Standard, 24 V DC 15117124 39.50 Options 2A DORMA TX 44 cover frame e.g.: FR-TX 44W, one cover frame, single aperture, IP 44, white 56394110 18.50 2A System 55 cover frame (FR = Frame) e.g.: FR-TX44W KDT, transparent hinged cover, white 56399010 27.50 2A System 55 cover frame (FR = Frame) FR-TX44A, Set 55 set of seals/gaskets for S55 components 56399000 14.50 3A CODIC CARD ID card CCH-0x CCH-01, pack of 10 cards, printed 19175001 106.00 3B CODIC CARD ID card CCH-0x CCH-02, pack of 10 cards, non-printed 19175002 106.00 >>> For security-relevant building components (e.g. external doors), taking the example of the SVP 6710 emergency escape lock with microswitch monitoring system, the external lever handle is engaged on detection of the MasterCard ID device 4 SVP 6xxx, fail-secure, 24 V DC, emergency escape lock with automatic locking action and split follower e.g.: SVP 6710 A 24 V DC 15671001 416.00 5 SVP-A connection cable e.g.: SVP-A 1000 49932990 42.50 6 KÜ cable loop, reinforced spiral e.g.: KÜ 480 15813000 41.50 7 I/O module IOM-C01 19357200 143.00 Interface module for connection of external components to the DORMA CODIC MasterCard access control system >>> Power supply unit for electric strike and/or SVP 6000 8 RZ-01 stabilised power supply unit, 24 V DC 56030100 147.00 8A PSU-xx concealed power supply unit e.g.: PSU-24 56030101 102.00 230 V AC RZ-01 CMC TÖ 117 Security Systems 82 Prices subject to change without notice 04/08

CODIC CARD Access control system. CODIC CMC-Hxx MasterCard access control system Keypad and proximity reader unit with evaluation and control unit for programming, management and control of up to 100 different access authorisation rights. During hours of darkness the keypad is backlit on activation. Programming is possible after presenting the MasterCard to the reader unit. The data storage location of the relevant authorisation can then be selected and edited using the keypad. Lost ID's can easily be overwritten or deleted by selecting the data storage location in programming mode. The read range of DORMA CCH-0x ID cards is typically 5 cm. Visual and audible signalling of authorised access and programming mode. The floating (no-volt) changeover contact can be used for controlling DORMA automatic operators, DORMA SVP emergency escape locks with automatic locking action or DORMA SVZ access control locks with automatic locking action, or for controlling DORMA automatic operators. Dimensions of cover (W x H x D) 55 x 55 x 9 mm Installation in standard device box (65 mm diameter) IP 30 protection in combination with DORMA FR-xx non-metallic frametype trim, or optionally up to IP 44 if using a DORMA FR-TX44 frametype trim and DORMA FR-TX44x KDT hinged cover, both in installed condition. Power supply: 24 V DC ± 10% 50/60 Hz, optionally 230 V AC ± 10% 50/60Hz with PSU-24 flush-mounting power supply unit. Power consumption: 1 W Relay output: Changeover contact 45 V DC; 35 V AC, max. 2A Scope of supply includes one CODIC MasterCard. Trims must be ordered separately. CODIC Mastercard CMC-H01 silver 19350101 0.067 372.00 CODIC Mastercard CMC-H10 white (similar to RAL 9010) 19350110 0.067 372.00 CODIC Mastercard CMC-H15 anthracite 19350115 0.067 372.00 For System 55 frame-type trims, see Pages 41 and 42. Identification card, see Pages 97. IOM-C01 I/O module for use in conjunction with the CODIC MasterCard system. I/O module offering enhanced security in external applications; can be used to add functionality to the DORMA CODIC MasterCard access control system. Interface module for connection of external components to the DORMA CODIC MasterCard access control system within the secure area. Four optocoupler inputs for transmission of external control commands, e.g. barring input for the first level, door contact for monitoring the door open time or detection of forced entry, and desktop pushbutton input. Four floating outputs for actuation control of external components or output of the signals: authorised entry; door open time exceeded; forced entry attempt and menace alarm. Installation in DCW junction box or by others. Power supply data: Supply voltage 24 V DC Current input max. 45 ma Optocoupler inputs: Uin 5 to 30 V, max. 28 ma Relay outputs: 24 V DC/1 A IOM-C01 19357200 0.085 143.00 PSU-xx flush-mounting power supply unit Switched power supply unit to EN 60950 for installation in a standard device box for DC power supply to DORMA electric strikes, locks or control units. Power supply: 230 V AC ± 10% 50/60Hz Output voltage: PSU-24 24 V DC Output current: 12 W Dimensions: 51 x 51 x 24 mm (max. diagonal 55 mm) Installation in standard device box (65 mm diameter) PSU-24 56030101 0.110 102.00 Security Systems 83 Prices subject to change without notice 04/08

XS Cylinder Order form Order form for XS cylinder. Please fax to +49 2333 793-871 Type Format Order-No. Number** /pack Packs XS-CM Reader module MasterCard 125 khz* 19020004 1 each 245.00... XS-CM Reader module MasterCard 125 khz* 19030004 10 each 2,421.00... XS-CO Reader module Offline* 125 khz * 19020204 1 each 293.00... XS-CO Reader module Offline* 125 khz* 19030204 10 each 2,884.00... XS-CBP Battery CR2 3 Volt 19154000 2 each 9.50... XS-CBC Battery tool 19154001 5 each 20.50... XS-CPT Emergency power feed Tool 19190005 1 each net 31.00... XS-PZ 01 Cylinder adapter 25 x 25 mm 19160101 1 each 40.00... XS-PZ 02 Cylinder adapter 25 x 30 mm 19160102 1 each 40.00... XS-PZ 03 Cylinder adapter 25 x 35 mm 19160103 1 each 40.00... XS-PZ 04 Cylinder adapter 25 x 40 mm 19160104 1 each 44.00... XS-PZ 05 Cylinder adapter 25 x 45 mm 19160105 1 each 48.00... XS-PZ 06 Cylinder adapter 25 x 50 mm 19160106 1 each 52.00... XS-PZ 07 Cylinder adapter 25 x 55 mm 19160107 1 each 56.00... XS-PZ 08 Cylinder adapter 25 x 60 mm 19160108 1 each 59.50... XS-PZ 09 Cylinder adapter 30 x 30 mm 19160109 1 each 40.00... XS-PZ 10 Cylinder adapter 30 x 35 mm 19160110 1 each 44.00... XS-PZ 11 Cylinder adapter 30 x 40 mm 19160111 1 each 48.00... XS-PZ 12 Cylinder adapter 30 x 45 mm 19160112 1 each 52.00... XS-PZ 13 Cylinder adapter 30 x 50 mm 19160113 1 each 56.00... XS-PZ 14 Cylinder adapter 30 x 55 mm 19160114 1 each 59.50... XS-PZ 15 Cylinder adapter 30 x 60 mm 19160115 1 each 63.50... XS-PZ 16 Cylinder adapter 35 x 35 mm 19160116 1 each 48.00... XS-PZ 17 Cylinder adapter 35 x 40 mm 19160117 1 each 52.00... XS-PZ 18 Cylinder adapter 35 x 45 mm 19160118 1 each 56.00... XS-PZ 19 Cylinder adapter 35 x 50 mm 19160119 1 each 59.50... XS-PZ 20 Cylinder adapter 35 x 55 mm 19160120 1 each 63.50... XS-PZ 21 Cylinder adapter 35 x 60 mm 19160121 1 each 67.50... XS-PZ 22 Cylinder adapter 40 x 40 mm 19160122 1 each 56.00... XS-PZ 23 Cylinder adapter 40 x 45 mm 19160123 1 each 59.50... XS-PZ 24 Cylinder adapter 40 x 50 mm 19160124 1 each 63.50... XS-PZ 25 Cylinder adapter 40 x 55 mm 19160125 1 each 67.50... XS-PZ 26 Cylinder adapter 40 x 60 mm 19160126 1 each 71.50... XS-PZ 27 Cylinder adapter 45 x 45 mm 19160127 1 each 63.50... XS-PZ 28 Cylinder adapter 45 x 50 mm 19160128 1 each 67.50... XS-PZ 29 Cylinder adapter 45 x 55 mm 19160129 1 each 71.50... XS-PZ 30 Cylinder adapter 45 x 60 mm 19160130 1 each 75.50... XS-PZ 31 Cylinder adapter 50 x 50 mm 19160131 1 each 71.50... XS-PZ 32 Cylinder adapter 50 x 55 mm 19160132 1 each 75.50... XS-PZ 33 Cylinder adapter 50 x 60 mm 19160133 1 each 79.50... XS-PZ S Cylinder adapter Special length 19160139 1 each on enquiry... XS-SP Sealing plug stainless steel 19018004 1 each 8.50... XS-PZ 61 Half cylinder adapter 25 x 10 mm 19160161 1 each 37.00... XS-PZ 62 Half cylinder adapter 30 x 10 mm 19160162 1 each 37.00... XS-PZ 63 Half cylinder adapter 35 x 10 mm 19160163 1 each 38.00... XS-PZ 64 Half cylinder adapter 40 x 10 mm 19160164 1 each 39.00... XS-PZ 65 Half cylinder adapter 45 x 10 mm 19160165 1 each 40.00... XS-PZ 66 Half cylinder adapter 50 x 10 mm 19160166 1 each 41.00... XS-KS Knob, small 29.5 mm 19180104 1 each 26.00... XS-KL Knob, large 34.0 mm 19180204 1 each 30.00... XS-KS Knob, small 29.5 mm 19180304 10 each 253.00... XS-KL Knob, large 34.0 mm 19180404 10 each 295.00... XS-P Anti-tamper rose stainless steel 19190004 1 each 84.50... CCH-01 CC* ID card CC* printed 19175001 10 each 106.00... CCH-02 ID card non-printed 19175002 10 each 106.00... CTH-03 Transponder fob black non-printed 19175003 10 each 108.00... ** per pack, CC* = CODIC CARD. All prices exclusive of statutory VAT. Further cylinder adapter designs available on request. * 125 khz = HITAG 1, HITAG 2, EM 4102 and EM 4150 without password protection. Security Systems 84 Prices subject to change without notice 04/08

XS Cylinder Order form You can determine the requisite cylinder adapter size by measuring either the profile cylinder located in the door or measuring the thickness dimensions of both the door and the fitting. When using the XS-P anti-tamper rose, make sure that you take into account additional thickness dimensions of 8 mm for the outside and 9 mm for the inside. Measuring the profile cylinder: From hole B, which receives the fixing screw located in the middle of the cylinder, measure the profile cylinder in both directions. This provides you with lengths L1 and L2, which you should then compare with the cylinder adapter dimensions in the table. Measuring the thickness values of the door and fitting: Located in the door lock below the bolt is the fixing screw that engages in hole B to retain the cylinder in the lock. From the centre of the screw, measure the door thickness in both directions, add the thickness of the fitting for both sides of the door and match the two dimensions with the cylinder adapter dimensions in the table. In order to avoid providing areas for mechanical attack, ensure that the cylinder adapter is as flush as possible with the door fitting. We recommend that the protrusion towards the outside be kept to a maximum of 2 mm. If none of the cylinder adapters available provide an appropriate fit, please enter the dimension that you need in the table at Special length. B L1 (outside) L2 (inside) Client details Last/Family name, first name Function/Department Company Address line 1 Date, signature Address line 2 Postal code Country Phone Fax E-mail Company stamp Security Systems 85 Prices subject to change without notice 04/08

XS Cylinder Reader Module Order No. kg/ P.U. / P.U. XS-CM reader module type MasterCard 125 khz Reader module for XS cylinder, MasterCard model, for access control on doors. This reader module detects proximity ID cards or transponder fobs. Up to 99 ID cards or transponder fobs can be authorised for operation in conjunction with the electronic XS-CM reader module. Where required, authorisations can be provided with a permanent-open enable function, allowing the door to be opened in the morning and locked at night. The XS MasterCard cylinder is designed as a learn-delete system. The ID cards or transponder fobs to be authorised can be read in directly at the door. Programming is performed by holding the programming card at the reader and presenting the ID devices at the reader module that are to be authorised or deleted. Lost ID cards or transponder fobs can also be deleted from the reader module using the programming card. The serial numbers of the formats HITAG 1, HITAG 2, EM 4102 and EM 4150 are read without password protection. The use of XS cylinders enables implementation of a wide range of master key concepts in line with given or changing circumstances. For added protection against tampering/manipulation, the reader module may only be removed and the battery changed on the basis of corresponding authorisations. Operating conditions are visually and audibly signalled. The modular kit concept enables installation in a wide range of different door thicknesses and satisfaction of various access control requirements. Finish: mock stainless steel/end face black Dimensions: 40 mm diameter, 41 mm in length In addition to the XS-CM electronic reader module, the following components will need to be ordered separately for the access side: XS-PZxx XS cylinder adapter in lengths of 50 to 110 mm XS-CBP XS battery pack XS-Kx mechanical XS knob or electronic reader module for the interior. Cylinder adapter lengths will need to be specified in accordance with the details of the door concerned and the selected fittings. XS-CM in packs of 1 19020004 0.152 245.00 XS-CM in packs of 10 19030004 1.550 2,421.00 Security Systems 86 Prices subject to change without notice 04/08

XS Cylinder Reader Module XS-CO reader module, Offline model 125 khz Reader module for XS cylinders, Offline model, for access control on doors in conjunction with the CODIC Card software CC-SOFT and upgrade CFU-01. The reader module reads the serial numbers of ID cards or transponder fobs of the formats on a Show&Go (proximity) basis without password protection. Up to 2,000 authorisations, 1,000 events and also the time and calendar profiles created under CC-SOFT can be stored in a non-volatile memory. The reader module checks the access authorizations on the basis of the individual authorisation data contained in the ID media, with calendar and public holiday rules and a weekly access time schedule. The reader module and cylinder adapter are electro-mechanically engaged on detection of a valid access authorisation, and the door can be opened by turning the reader module. The XS-CO reader module is commissioned via the infra-red interface of a PDA (Palm) in conjunction with the access control software, and the same procedure is used for uploading the access authorizations. The PDA likewise serves to read out the event data and for transmission of the information to the PC. The PDA can also be used for local analysis of the access event data directly at the door by implementing the diagnostics function. For added protection against tampering/manipulation, the reader module may only be removed and the battery changed on the basis of corresponding authorizations transmitted via the PDA. Operating conditions are visually and audibly signalled. Finish: mock stainless steel/end face black Dimensions: 40 mm diameter, 41 mm in length In addition to the XS-CO electronic reader module, the following components will need to be ordered separately for the access side: XS-PZxx XS cylinder adapter in lengths of 50 to 110 mm XS-CBP XS battery pack XS-Kx mechanical XS knob or electronic reader module for the interior. Cylinder adapter lengths will need to be specified in accordance with the details of the door concerned and the selected fittings. XS-CO in packs of 1 19020204 0.195 293.00 XS-CO in packs of 10 19030204 1.550 2,884.00 Security Systems 87 Prices subject to change without notice 04/08

XS Cylinder Accessories Order No. kg/ P.U. / P.U. XS-PZxx cylinder adapters Cylinder adapters for combination with XS cylinder components. Suitable for non-directional installation in Europrofile (PZ) locks according to DIN 18254. Europrofile cylinders of modular design from 25/35 mm to 50/60 mm; other dimensions on request. In addition to the XS cylinder adapter, the following components must be separately ordered: Electronic XS-Cx reader module for the access side XS-CBP XS battery pack XS-Kx mechanical XS knob or electronic reader module for the interior. Cylinder adapter lengths will need to be specified in accordance with the details of the door concerned and the selected fittings. When using the XS-P anti-tamper rose, ensure that the additional dimensions of 8 mm for the outside and 9 mm for the inside are additionally taken into account. Packs of 1 Type Dimensions XS-PZ 01 25 x 25 mm 19160101 0.090 40.00 XS-PZ 02 25 x 30 mm 19160102 0.098 40.00 XS-PZ 03 25 x 35 mm 19160103 0.110 40.00 XS-PZ 04 25 x 40 mm 19160104 0.122 44.00 XS-PZ 05 25 x 45 mm 19160105 0.136 48.00 XS-PZ 06 25 x 50 mm 19160106 0.148 52.00 XS-PZ 07 25 x 55 mm 19160107 0.156 56.00 XS-PZ 08 25 x 60 mm 19160108 0.172 59.50 XS-PZ 09 30 x 30 mm 19160109 0.110 40.00 XS-PZ 10 30 x 35 mm 19160110 0.122 44.00 XS-PZ 11 30 x 40 mm 19160111 0.136 48.00 XS-PZ 12 30 x 45 mm 19160112 0.148 52.00 XS-PZ 13 30 x 50 mm 19160113 0.156 56.00 XS-PZ 14 30 x 55 mm 19160114 0.172 59.50 XS-PZ 15 30 x 60 mm 19160115 0.182 63.50 XS-PZ 16 35 x 35 mm 19160116 0.136 48.00 XS-PZ 17 35 x 40 mm 19160117 0.148 52.00 XS-PZ 18 35 x 45 mm 19160118 0.156 56.00 XS-PZ 19 35 x 50 mm 19160119 0.172 59.50 XS-PZ 20 35 x 55 mm 19160120 0.182 63.50 XS-PZ 21 35 x 60 mm 19160121 0.198 67.50 XS-PZ 22 40 x 40 mm 19160122 0.156 56.00 XS-PZ 23 40 x 45 mm 19160123 0.172 59.50 XS-PZ 24 40 x 50 mm 19160124 0.182 63.50 XS-PZ 25 40 x 55 mm 19160125 0.198 67.50 XS-PZ 26 40 x 60 mm 19160126 0.208 71.50 XS-PZ 27 45 x 45 mm 19160127 0.182 63.50 XS-PZ 28 45 x 50 mm 19160128 0.198 67.50 XS-PZ 29 45 x 55 mm 19160129 0.208 71.50 XS-PZ 30 45 x 60 mm 19160130 0.214 75.50 XS-PZ 31 50 x 50 mm 19160131 0.208 71.50 XS-PZ 32 50 x 55 mm 19160132 0.214 75.50 XS-PZ 33 50 x 60 mm 19160133 0.218 79.50 XS-PZ S Custom length 19160139 on enquiry Security Systems 88 Prices subject to change without notice 04/08

XS Cylinder Accessories XS-PZxx half cylinder adapter Half cylinder adapter for combination with XS cylinder components. Suitable for installation e.g. in keyswitches. Europrofile cylinders of 25 /10mm to 50/10mm. In addition to the XS half cylinder adapter, the following components must be separately ordered: Electronic XS-Cx reader module XS-CBP XS battery pack Half cylinder adapter lengths will need to be specified in accordance with the details of the door concerned and installation requirements. When using the XS-P anti-tamper rose, ensure that the outside dimension of 8 mm is additionally taken into account. Packs of 1 Type Dimensions XS-PZ 61 25 x 10 19160161 0.095 37.00 XS-PZ 62 30 x 10 19160162 0.103 37.00 XS-PZ 63 35 x 10 19160163 0.115 38.00 XS-PZ 64 40 x 10 19160164 0.150 39.00 XS-PZ 65 45 x 10 19160165 0.180 40.00 XS-PZ 66 50 x 10 19160166 41.00 XS-Kx knob Mechanical knob combination with XS cylinder components. Recessed grip; mock-stainless steel finish Pack of 1 Type Diameter XS-KS 29.5 mm 19180104 0.112 26.00 XS-KL 34.0 mm 19180204 0.138 30.00 Pack of 10 Type Diameter XS-KS 29.5 mm 19180304 1.120 253.00 XS-KL 34.0 mm 19180404 1.380 295.00 XS-SP seal plug Plug for sealing the core hole of a cylinder adapter only used on one side. (Not for use with half cylinder adapters) XS-SP 19018004 0.022 8.50 XS-CBP battery pack Battery pack comprising 2 single CR2 lithium batteries for fitting to an XS reader module. Supplied in packs of 2 XS-CBP 19154000 0.022 9.50 XS-CBC battery change tool Battery change tool for easy battery change in XS reader modules. Caution: The battery change operation may only be carried out in conjunction with a battery change authorisation allocated to the reader module concerned. Supplied in packs of 5 XS-CBC 19154001 0.012 20.50 Security Systems 89 Prices subject to change without notice 04/08

XS Cylinder Accessories XS-CPT emergency power supply unit Detachable emergency power supply unit for XS-Cx reader modules. The unit enables the reader module to be externally powered even after the power level falls below the third warning threshold. The power is transmitted via the contact pins on the end face of the reader module and the spring contacts of the power supply unit, using a 9 V block battery type 6LR61 (not included). Dimensions: 35 x 30 x 18 mm In packs of 1 net XS-CPT emergency power unit 19190005 0.020 31.00 XS-P anti-tamper rose for XS cylinders Enhanced mechanical protection of XS cylinders, resistant to sabotage and vandalism. Fitting the anti-tamper rose to XS cylinders satisfies the requirements of DIN EN 1303 in relation to the performance and protection of lock cylinders. When determining the dimensions, ensure that the 8 mm for the outside and 9 mm for the inside are additionally taken into account. XS-P anti-tamper rose 19190004 84.50 Security Systems 90 Prices subject to change without notice 04/08

CODIC CARD System overview CODIC CARD system overview Parameterisation and data exchange via Laptop (offline) for hard-wired readers Recommended cabling: Mains feeder: NYM-1 3x1.5 System cabling: I-Y (ST) Y 2x2x0.8 CCP-x NMC 230 VAC ± 10 % 50/60 Hz RS 232 max. 15 m ACU-02 DCW-Bus max. 300 m (network range) CRx Electric strike CRx CRx CRx Electric Electric Electric strike strike strike Door group with max. 4 doors (each with one reader) Components Door 1. 2. 3. 4. 5. 6. 7. Maximum equipment configuration Access control ACU-02 DCW X X 31 access controls Power supply unit PSU-01 O O 31 power supply units Reader CRx X X X X X X X 124 readers Input/output module IOMx 39 input/output modules RFS-V01 reader guard O O O O O O O 124 for CRH-V01 readers Identification cards CCxx X 5,000 ID cards Programming adapter CCP-xx1 O 1 programming adapter Basic software package CC-Soft X 1 basic software package Software upgrade CCU-01 O 1 audit trail/event history upgrade Software upgrade CLU-01 O 1 layout plan upgrade Software upgrade CRU-01 O 1 reportupgrade Software uprgrade CTU-01 O 1 door time function upgrade CODIC fitting upgrade CFU-01 O 1 XS component upgrade Interface controller CIC-02 X 1 interface converter Standard null modem cable NMC X X 1 standard null modem cable DCW bus hub 93 DCW bus hubs DCW bus hub box 93 DCW bus hub boxes XS-Offline components X 999 as pure XS system 875 in mixed mode PDA X 1 PDA for data transmission when using XS components X = Minimum requirement / O = Option / = Installation possible Security Systems 91

CODIC CARD System overview CODIC CARD system overview Parameterisation and data exchange via laptop (online) for network hardware Recommended cabling: LAN CIC-02 Mains feeder: NYM-1 3x1.5 System cabling: I-Y (ST) Y 2x2x0.8 RS 485: Li2YCY (TP) 0.6 CCP-x RS 485 max. 5,000 m ACU-02 ACU-02 230 VAC ± 10 % 50/60 Hz ACU-02 DCW -Bus max. 300 m (network range) CRx Electric strike CRx CRx CRx Electric Electric Electric strike strike strike max. 124 doors (each with one reader) with up to 31 ACU-02 DCW CODIC CARD access control system For logging and evaluation of up to 5,000 individually programmable and erasable access rights in 20 door-specific and/or personnel-specific time matrices. The hardware for constructing the access control system comprises the following: ACU-02 DCW evaluation and control unit, CRx-xx DCW reader and IOM-xxx DCW I/O module. Each ACU-02 DCW can manage up to 4 readers and 3 I/O modules. With a maximum of 31 evaluation and control units, a network can be created with up to 124 readers and 93 I/O modules. The maximum cable length in a network is 5,000 m. Up to 5,000 authorised access events can be logged in the evaluation and control unit. For data communication between the evaluation and control units and the PC, there is an RS 232 interface for standalone mode (off-line) or an RS 485 interface for network mode (online). Optocoupler inputs and floating outputs are provided for the transmission of external signals and control commands for the actuation of external components such as DORMA SVP emergency escape locks with automatic locking action, electric strikes and motor locks. In combination with XS cylinders or XS fittings as offline components, the system can be expanded to up to 999 doors. Data transfer to the XS components is performed with a PDA. CODIC CARD CC-SOFT software The software manages the access authorisation rights and hardware on Windows platforms 2000/XP. The user is guided through the program by means of an integrated Wizard. The need to transfer modified data to the individual access control units or XS components is prompted. Various rights can be managed on a password-protected basis. Users and doors can be arranged in up to 20 groups and are linked to different non access/ barred days determined on the basis of an integrated calendar. The access event and activity records of the doors can be retrieved from the audit trail (events history) database and sorted according to various criteria. Additional functions can be generated with the optional software upgrade modules: Layout plan upgrade module: Integration of active links in userspecific layout plans (up to 20 levels) enables direct management, visualisation and remote control of net worked doors from the layout plan. Report upgrade module: This module facilitates user documentation of access rights, doors and specific groupings. Client upgrade module: Different clients/entities can access both common doors and their own doors via a CODIC CARD server in one hardware system. Allows audit trail data (events history) to be processed separately for each client. Door/ time function upgrade module: Enables different media to be combined in a time-related and door-specific basis and allows doors to be managed via time windows. XS components upgrade: For implementation of excess components for offline operation. The upgrade consists of the XS manager (PDA software) for data transfer, and corresponding CC-SOFT facilities for the parameterisation and management of components operated in the offline mode. System requirements: IBM-compatible PC (Pentium or later, 200 MHz or higher) with WIN 2000 or WIN XP operating system; CD-ROM drive, 64 MB RAM; 1024 x 768 pixel graphics with min. 256 colours; 60 MB available hard disc memory and capacity for data backup. One free COM interface (V24 standard) and one free Ethernet 10/100, possibly one USB in addition. Security Systems 92

CODIC CARD Access control system CODIC CARD access control unit ACU-02 DCW for the connection of up to four reader units CRx-xx DCW and up to three I/O modules IOM-G00 DCW. Wiring via DORMA DCW bus system. For the storage and evaluation of up to 5,000 individually programmable and erasable authorisations in 20 door or person-related time zones. Logging of max. 5,000 authorised access events. Data saving in the case of power failure by integrated lithium battery. Included in the control unit are four optical coupler inputs for the transmission of external signals and control commands (floating) and five floating outputs for the control of external components - such as DORMA SVP anti-panic locks with automatic locking action, PROSIS high-security jamb-concealed locks, electric keeps, motor locks etc. - or for the output of signals. Unauthorised opening of the enclosure is monitored. Parameterisation/programming with the aid of CODIC CARD CC-SOFT software on WINDOWS platform WIN 95/98 or WIN NT4.0 service pack 6. With max. 31 access control units ACU-02 DCW a network of up to 125 reader units can be formed. For the data communication either interface RS 232 (off-line operation) or RS 485 (on-line operation) are available. The maximum network expansion in on-line operation may be up to 5,000 m. Supply voltage on site: 24 V DC ± 10% 50/60 Hz optional 230 V AC ± 10% 50/60 Hz with power supply board PSU-01. Current input: 24 VA with complete periphery Optical coupler inputs: 24 V DC Relay outputs: change-over contact 45 V DC / 35 V AC / max. 2 A Sheet steel enclosure (coated similar to RAL 7016) for surface mounting Dimensions ACU-02 (W x H x D): 146 x 244 x 59 mm Dimensions ACU-02H (W x H x D): 146 x 244 x 59 mm Protection category: IP 20 ACU-02 DCW 19350011 0.120 565.00 ACU-02H DCW for top-hat rail installation 19350012 0.120 565.00 CODIC CARD power supply board PSU-01 Power supply board for the supply of one ACU-02 DCW and CIC-02, four reader units CRH-xxx DCW and three I/O modules IOM-xxx DCW. Prepared for fixing into the enclosure of the access control unit ACU-02 DCW. Supply voltage: 230 V DC ± 10% 50/60 Hz Current input: 24 VA Dimensions (W x H x D): 90 x 70 x 35 mm PSU-01 19350002 0.540 142.00 DORMA interface controller CIC-02 Processor-assisted interface converter RS 485 / LAN for the networking of CODIC CARD access control units ACU-02 DCW with the network interface of the computer in case in online operation. 19493202 1.626 668.00 CODIC CARD programming adapter CCP-x Programming adapter for convenient reading of serial numbers of ID cards or transponder fobs into CC-SOFT access control software. Supply voltage: via plug-in power pack 230 V AC. Connection to a free serial interface (V24 standard) of the computer Dimensions (W x H x D): 120 x 65 x 45 mm. Reader for 125 khz read formats HITAG 1, HITAG 2, EM 4102 and EM 4150 without password protection CCP-H01 19250100 0.700 567.00 For the MIFARE reading process CCP-M11 19251100 0.700 638.00 For the LEGIC reading process CCP-L21 19252100 0.700 638.00 Security Systems 93 Prices subject to change without notice 04/08

CODIC CARD Access control system DORMA null modem-cable NMC For the data exchange between the CODIC CARD access control unit ACU-02 DCW and the serial interface (V24 standard) of the computer in group stand-alone off-line operation. Length 3 m. NMC 19491720 0.210 33.50 CODIC CARD double I/O module IOM-G00 DCW BUS coupler module for the connection of products with conventional wiring to the DORMA DCW system bus. Two optocoupler inputs for the transmission of external signals or control commands and two outputs for the control of external components. The module can be installed in standard device boxes Ø 65 mm as well as surface-applied. The I/O modules can be combined with the switch ranges DORMA FR-x, Berker, GIRA, Jung or Merten. The supply voltage of the I/O module may optionally be drawn via the DCW bus from the access control unit ACU-02 DCW. Optocoupler inputs: 24V DC Relay outputs: change-over contact 45V DC / 35V AC / max. 2 A Dimensions of the cover (W x H): 55 x 55 mm Installation in standard device box (62 mm deep) to DIN. Covers in white (sim. to RAL 9010), silver and anthracite grey included in scope of supply. IOM-G00 DCW 19357100 0.100 297.00 CODIC CARD System 55 reader insert CRx-Gxx DCW Reader insert for fitting in System 55 enclosures, for the Show & Go (proximity) reading of the serial numbers of ID cards or transponder fobs. Typical reading distance with ID cards approx. 5 cm. The reading operations are both audibly and visually acknowledged. The unit cover is antitamper monitored. Suitable for installing in both standard device boxes to DIN or as surface-mounted units. The readers can be combined with the non-metallic frame-type switch trim ranges DORMA FR-x, Berker, GIRA, Jung or Merten. Power supply to the reader is via the DCW bus from access control unit ACU-02 DCW. Dimensions of cover (W x H): 55 x 55 mm. Installation in standard device box (62 mm deep) to DIN Reader for 125 khz read formats HITAG 1, HITAG 2, EM 4102 and EM 4150 without password protection CRH-G01 DCW reader, silver 19250401 0.160 303.00 CRH-G10 DCW reader, white (sim. to RAL 9010) 19250410 0.160 303.00 CRH-G15 DCW reader, anthracite grey 19250415 0.160 303.00 For the MIFARE reading process CRM-G01 DCW reader, silver 19251401 0.150 391.00 CRM-G10 DCW reader, white (sim. to RAL 9010) 19251410 0.160 391.00 CRM-G15 DCW reader, anthracite grey 19251415 0.160 391.00 For the LEGIC reading process CRL-G01 DCW reader, silver 19252401 0.160 412.00 CRL-G10 DCW reader, white (sim. to RAL 9010) 19252410 0.160 412.00 CRL-G15 DCW reader, anthracite grey 19252415 0.160 412.00 Security Systems 94 Prices subject to change without notice 04/08

CODIC CARD Access control system CODIC CARD System 55 keypad reader unit CRH-Kxx DCW Keypad type reader unit, System 55 design, for inputting a PIN or access code and/or for the Show & Go (proximity) reading of the serial numbers of ID cards or transponder fobs. Typical reading distance with ID cards approx. 5 cm. The keypad inputs and/or reading operations are both audibly and visually acknowledged. The unit cover is anti-tamper monitored. The keys of the keypad are illuminated in darkness. Suitable for installing in both standard device boxes to DIN or as surface-mounted units. The readers can be combined with the non-metallic frame-type switch trim ranges DORMA FR-x, Berker, GIRA, Jung or Merten. Power supply to the keypad reader is via the DCW bus from access control unit ACU-02 DCW. Dimensions of cover (W x H): 55 x 55 mm. Installation in standard device box (62 mm deep) to DIN Keypad reader for 125 khz read formats HITAG 1, HITAG 2, EM 4102 and EM 4150 without password protection CRH-K01 DCW keypad reader, silver 19250501 0.182 453.00 CRH-K10 DCW keypad reader, white (similar to RAL 9010) 19250510 0.070 453.00 CRH-K15 DCW keypad reader, anthracite grey 19250515 0.180 453.00 CODIC CARD System 55 keypad insert CRP-Pxx DCW Keypad insert, System 55 design, for inputting a PIN or access code or combination with a Show & Go (proximity) reader using the read formats MIFARE, LEGIC or the key reader CRK-Gxx. The keypad inputs are both audibly and visually acknowledged. The unit cover is anti-tamper monitored. The keys of the keypad are illuminated in darkness. Suitable for installing in both standard device boxes to DIN or as surface-mounted units. The keypad insert can be combined with the frame-type switch trim ranges DORMA FR-x, Berker, GIRA, Jung or Merten. Power supply to the keypad is via the DCW bus from access control unit ACU-02 DCW. Dimensions of cover (W x H): 55 x 55 mm. Installation in standard device box (62 mm deep) to DIN CRP-P01 DCW keypad reader, silver 19250801 0.182 269.00 CRP-P10 DCW keypad reader, white (similar to RAL 9010) 19250810 0.170 269.00 CRP-P15 DCW keypad reader, anthracite grey 19250815 0.180 269.00 CODIC CARD System 55 key-operated reader unit Discontinued product lines CRK-Gxx DCW Reader unit of System 55 design for reading electronically encoded CODIC CC keys. The reading operations are both audibly and visually acknowledged. The unit cover is anti-tamper monitored. The reader slot is illuminated. Suitable for installing in both standard device boxes to DIN or as surface-mounted units. The readers can be combined with the non-metallic frame-type switch trim ranges DORMA FR-x, Berker, GIRA, Jung or Merten. Power supply to the reader is via the DCW bus from access control unit ACU-02 DCW. Dimensions of cover (W x H): 55 x 55 mm. Installation in standard device box (62 mm deep) to DIN CRK-G01 DCW reader, silver 19250301 0.300 286.00 CRK-G10 DCW reader, white (similar to RAL 9010) 19250310 0.195 286.00 CRK-G15 DCW reader, anthracite grey 19250315 0.193 286.00 (for CC keys, see page 112) Long-range reader For the proximity reading of HITAG 1 ID cards or transponder fobs. Reading distance 30 cm, 50 cm or 70 cm depending on type. Reader powered by integral power supply unit. on enquiry Reader units with Show&Go (proximity) reading technologies of the System 55 design can be combined with non-metallic trims. Security Systems 95 Prices subject to change without notice 04/08

CODIC CARD Access control system CODIC CARD reader unit, Siedle type, CRx-Sxx DCW Reader unit for installation in the Siedle intercom system 611, for Show & Go (proximity) reading of the serial numbers of ID cards or transponder fobs. Typical reading distance with ID cards approx. 5 cm. The reading operations are both audibly and visually acknowledged. The unit cover is anti-tamper monitored. Power supply to the reader is via the DCW bus from access control unit ACU-02 DCW. Dimensions of cover (W x H x D): 99 x 99 x 21 mm. Class of protection: up to 1P 54 depending on installed condition Reader for 125 khz read formats HITAG 1, HITAG 2, EM 4102 and EM 4150 without password protection CRH-S01 DCW reader, silver 19250201 0.211 350.00 CRH-S10 DCW reader, white (sim. to RAL 9010) 19250210 0.214 350.00 For the MIFARE reading process CRM-S01 DCW reader, silver 19251201 0.211 512.00 CRM-S10 DCW reader, white (sim. to RAL 9010) 19251210 0.211 512.00 For the LEGIC reading process CRL-S01 DCW reader, silver 19252201 0.211 541.00 CRL-S10 DCW reader, white (sim. to RAL 9010) 19252210 0.211 541.00 CODIC CARD reader, vandalism-protected design, CRx-V01 DCW Reader of impact-proof plastics for surface-mounting, for Show & Go (proximity) reading of the serial numbers of ID cards or transponder fobs. Typical reading distance with ID cards approx. 5 cm. The reading operations are both audibly and visually acknowledged. Power supply to the reader is via the DCW bus from access control unit ACU-02 DCW. The interconnecting cable has a length of 4 m. Dimensions of cover (W x H x D): 95 x 95 x 15 mm. Class of protection: IP 64 in installed condition Reader for 125 khz read formats HITAG 1, HITAG 2, EM 4102 and EM 4150 without password protection CRH-V01 DCW reader, silver 19250601 0.285 408.00 For the MIFARE reading process CRM-V01 DCW reader, silver 19251601 0.285 474.00 For the LEGIC reading process CRL-V01 DCW reader, silver 19252601 0.285 486.00 RFS-V01 reader guard Reader guard and installation set for improving the performance of the CODIC CARD reader CRx-V01, of anti-tamper design for metallic environments. Dimensions (W x H x D): 95 x 95 x 12 mm In packs of 1 RFS-V01 reader guard 19210601 0.065 68.50 Security Systems 96 Prices subject to change without notice 04/08

CODIC CARD Access control system CODIC CARD System 55 reader insert 55 CRx-Txx DCW Reader insert for the TX44 system, for the Show Go (proximity) reading of the serial numbers of ID cards or transponder fobs. Typical reading distance with ID cards approx. 5 cm. The reading operations are both audibly and visually acknowledged. The unit cover is anti-tamper monitored. Suitable for installing in both standard device boxes to DIN or as surface-mounted units. The readers can be combined with the nonmetallic frame-type switch trim ranges DORMA FR-TX44 or GIRA. Power supply to the reader is via the DCW bus from access control unit ACU- 02 DCW. Suitable for installing in standard device box (62 mm deep) to DIN or in the DORMA Design control column. Readers for 125 khz read formats HITAG 1, HITAG 2, EM 4102 and EM 4150 without password protection CRH-T01 DCW reader, silver 19250701 0.161 338.00 CRH-T10 DCW reader, white (sim. to RAL 9010) 19250710 0.161 338.00 CRH-T15 DCW reader, anthracite grey 19250715 0.161 338.00 for the MIFARE reading process CRM-T01 DCW reader, silver 19251701 0.100 422.00 CRM-T10 DCW reader, white (sim. to RAL 9010) 19251710 0.100 422.00 CRM-T15 DCW reader, anthracite grey 19251715 0.100 422.00 for the LEGIC reading process CRL-T01 DCW reader, silver 19252701 0.100 497.00 CRL-T10 DCW reader, white (sim. to RAL 9010) 19252710 0.100 497.00 CRL-T15 DCW reader, anthracite grey 19252715 0.100 497.00 CODIC CARD identification card CCx-0x ID card with passive transponder for the identification of authorised persons. Each ID card contains an electronic serial number. The ID card can also be used with other systems using the same reading process in each case, e.g. canteen accounting. Dimensions (W x H x D): 85 x 54 x 0.75 mm Printed on both sides: Front face with two-colour imprint CODIC CARD Rear face monochrome with 6-digit serial number Sold in packs of 10 cards. for 125 khz readers (HITAG 1) CCH-01 19175001 0.006 106.00 MIFARE CCM-01 19175011 0.006 119.00 LEGIC CCL-01 19175021 0.006 126.00 without imprint for 125 khz readers (HITAG 1) CCH-02 19175002 0.006 106.00 MIFARE CCM-02 19175012 0.006 119.00 LEGIC CCL-02 19175022 0.006 126.00 CODIC CARD transponder fob CTx-03 Transponder fob with passive transponder for the identification of authorised persons. Each ID fob contains an electronic serial number. The ID fob can also be used with other systems using the same reading process in each case, e.g. canteen accounting. Dimensions (W x H x D): 30 x 45 x 1.5 mm Sold in packs of 10 fobs. for 125 khz readers (HITAG 1) CTH-03 19175003 0.040 108.00 MIFARE CTM-03 19175013 0.040 127.00 LEGIC CTL-03 19175023 0.040 134.00 Security Systems 97 Prices subject to change without notice 04/08

CODIC CARD Access control system CODIC CARD CC-SOFT software Now with even more features Windows-based access control software available as single or multi-user version. For parameterisation and management of users, access rights, doors, reader units and time zones in the CODIC CARD access control system. Up to 5,000 access rights can be managed on 124 networked reader units via 31 control units, or optionally up to 999 XS components in 20 time zones. Authorised persons and doors can be arranged in groups, thus enabling them to be managed and amended efficiently. Data records can be exported and imported. In terms of reader unit and data management, one system is able to deal with contacting CODIC key readers as well as CODIC CARD keypad readers, proximity ( non-contact ) CODIC CARD readers or XS components. Time zones are easy to define with the combination of two time windows in each daily schedule and seven daily schedules in each weekly schedule. Special days can be additionally entered in the stored calendar. The access event and activity records of the doors can be retrieved from the audit trail (events history) database and sorted according to various criteria. The need to transfer modified data to the individual access control units or XS components is displayed. An integrated wizard is available to help inexperienced users through the intricacies of the program. The integrated diagnostics tool gives information about the hardware used, its firmware status and data transfer. Different usage rights can be managed with password protection. By activating the TMS function on installed DORMA TMS software, the user can choose to switch to parameterisation of TMS emergency exit control systems and acces management, thus enabling the management of the access control functions of DORMA TMS control units. Additional functions can be generated with the optional upgrade modules: Layout Plan upgrade module: Integration of active links in user-specific layout plans (up to 20 levels) enables management, visualisation and remote control of doors directly from the layout plan. Report upgrade module: This module facilitates user documentation of access rights, doors and specific groupings. Client upgrade module: Different clients/parties can access both common doors and their own doors via the server within one hardware system. Audit trail (events history) data is processed separately for each client. Door/Time Function upgrade module: Enables different media to be combined on a time-related and door-specific basis and enables doors to be managed via time windows. Upgrade for XS components System requirements: IBM-compatible PC (Pentium or later, 200 MHz or higher) with WIN 2000 or WIN XP operating system; CD-ROM drive, 64 MB RAM; 1024 x 768 pixel graphics with min. 256 colours; 60 MB available hard disc memory and capacity for data backup. One free COM interface (V24 standard) and one free Ethernet 10/100, possibly one USB in addition. Scope of supply: 1 CD-ROM CC-SOFT basic software package 19650001 0.080 402.00 Security Systems 98 Prices subject to change without notice 04/08

CODIC CARD Access control system CODIC CARD software upgrade floor plan CLU-01 Software upgrade to expand the basic software CC-Soft in order to load up to ten floor plans of a building in BMP or JPG format. For an easy management the links to door data can be generated or deleted directly on the floor plan and lateron the functions such as group management, door-open alarm or current supply time can be set or changed. Scope of supply: 1 CD-ROM CLU-01 19650201 0.020 233.00 CODIC CARD software upgrade report CRU-01 Software upgrade to expand the basic software CC-Soft for a comfortable documentation of system-related data of users, doors and their groups and time zones. Using the software upgrade 'history' also usage data can be documented. Scope of supply: 1 CD-ROM CRU-01 19650301 0.020 233.00 CODIC CARD CCU-01 Client software upgrade module Upgrade expansion module for the CC-Soft basic software package for easy management of different clients in one or more buildings. Enables the use of shared and client-specific doors within one hardware system via the CODIC CARD server. Audit trail (events history) and usage data can be processed separately for each client. Scope of supply: 1 CD-ROM CCU-01 19650401 0.090 233.00 CODIC CARD CTU-01 Door/Time Function software upgrade module Upgrade expansion module for the CC-Soft basic software package for easy combination of different media (intellectual/physical/none) on a time-specific and door-specific basis. Access rights can be increased to a higher security level by combination with a max. 6-digit PIN. In addition, doors can be opened or closed on a timecontrolled basis independently of access rights. Scope of supply: 1 CD-ROM CTU-01 19650501 0.092 233.00 CODIC CARD software upgrade for XS components CFU-01 Software upgrade for extending the basic software CC-Soft for enhanced convenience in the management of XS hardware components operated offline. The upgrade enables exchange of the data relating to XS components operated offline such as door fittings or electronic cylinders where the appropriate computer hardware is available. The data covers the access, audit trail and diagnostics data and also the battery status of XS components. Scope of supply: 2 CD-ROMs CFU-01 + XS Manager 19650601 0.190 273.00 PDA (PALM) PDA (PALM) for data transmission with an XS component operating in the offline mode. Communication with the XS component is effected by an infra-red interface. Communication with the higher-level PC system is by USB. Integration of the PDA within the CODIC CARD system requires installation of the PDA-specific software and also the XS Manager (XS Upgrade component). PDA 19493300 0.661 197.00 Security Systems 99 Prices subject to change without notice 04/08

XS fitting Interior Door Fittings XS fitting, offline type The DORMA XS anti-tamper/security fitting is a mock stainless steel internal door unit with integral proximity reader and electronic evaluation and control unit for offline operation in conjunction with the CODIC CARD software CC-SOFT and upgrade CFU-01. Access authorisation checking is performed by the fitting on the basis of individual access rights as stored in the ID devices, calendar and special/ public holiday matrices and an access time schedule based on a weekly plan. In the event of an approved access attempt, the lever handle is electro-mechanically engaged, allowing the door to be opened by lever handle operation. This and the battery status are visually and audibly signalled. The XS fitting is commissioned via the infra-red interface of the PDA (Palm) in conjunction with the access control software, with the access authorisation rights being downloaded by the same means. The PDA can also be used to read out the audit trail/events history data and to transfer this data to the PC for evaluation. Up to 2000 access rights, 1000 events and the time and calendar matrices created using CC-SOFT can be stored in the integrated, non-volatile memory of the fitting. The XS fitting offers diagnostic functions for analysis of the access checks directly at the door. The XS fitting can be used in conjunction with mortise locks to DIN 18251 or the DORMA SVP range of emergency escape locks. No wiring is required at the door. The XS fitting is powered by replaceable batteries. In the standby mode, it is virtually de-energised and is activated by a capacitive proximity detector which responds to the presentation of an ID device. The XS fitting is prepared for retrofitting with an XS radio control module. It can thus be expanded to and incorporated within an online access control system. Finish: mock stainless steel/reader unit anthracite grey Dimensions: 66 x 248 x 79 mm Power supply: 4x AA batteries, 1.5 V, alkaline (not included). In addition to the XS fitting, the following components must be ordered separately for the access side: IBL-I 004 internal backplate MS-IB installation set EZ mortise lock cylinder SEZ key for mortise lock cylinder (see page 103) XS fitting for 125 khz read formats HITAG 1, HITAG 2, EM 4102 and EM 4150 without password protection RH lever handle 19028204 1.300 350.00 LH lever handle 19029204 1.300 350.00 XS fitting, MIFARE read process RH lever handle 19028404 1.300 381.00 LH lever handle 19029404 1.300 381.00 XS fitting, LEGIC read process RH lever handle 19028604 1.300 422.00 LH lever handle 19029604 1.300 422.00 Security Systems 100 Prices subject to change without notice 04/08

CODIC IBL Interior Door Fittings IBL-M interior door fitting Interior door fitting with reader for manual programming. Battery-operated, programmable interior door fitting for operation of the mortise lock via electro-mechanically disengaged lever handle. Operates by insertion of electronically encoded CODIC CC-U unique keys. With electronic unit for management of up to 60 CODIC CC-U unique keys divided into 3 differently authorised groups. Visual and audible signalling of authorised access, programming mode and low battery voltage. Programming performed with CODIC CC-PR programming key. For mortise locks with backsets > 35 mm, follower-to-keyway centres of 72 to 105 mm, and door thicknesses of 32 to 105 mm. Provided the projection is < 17 mm, the existing lock cylinder can be used for the mechanical emergency opening or locking of the lock from the inside. Power supply: 4 x AA batteries, 1.5 V, alkaline (not included). CODIC IBL-M interior door fittings are made up of the following products which must be ordered separately: - CODIC IBL-A external backplate with electronic unit - CODIC MS-IB installation set - CODIC EZ lockable cylinder insert - CODIC SEZ keys for lockable cylinder insert IBL-H interior door fitting for hotels Interior door fitting with reader for programming with the HS-Soft software package. Battery-operated, programmable interior door fitting for operation of the mortise lock via electro-mechanically disengaged lever handle. Operates by insertion of electronically encoded CODIC CC-I keys. With electronic unit for management of access authorisations assigned with the aid of the CODIC HS-Soft software for CODIC CI-M manager keys, CI-G guest keys and CI-P personnel keys. For mortise locks with backsets > 35 mm, follower-to-keyway centres of 72 to 105 mm, and door thicknesses of 32 to 105 mm. Provided the projection is < 17 mm, the existing lock cylinder can be used for the mechanical emergency opening or locking of the lock from the inside. Power supply: 4 x AA batteries, 1.5 V, alkaline (not included). CODIC IBL-H interior door fittings are made up of the following products which must be ordered separately: - CODIC IBL-A external backplate with electronic unit - CODIC MS-IB installation set - CODIC EZ lockable cylinder insert - CODIC SEZ keys for lockable cylinder insert For combination with CODIC IBL-I internal backplate or standard commercial backplates/roses. Security Systems 101 Prices subject to change without notice 04/08

CODIC IBL Interior Door Fittings IBL-A external backplate with electronic unit M External backplate with lever handle and electronic unit for management of up to 30 CODIC CC-U unique keys divided into 3 differently authorised groups. Visual and audible signalling of authorised access, programming mode and low battery voltage. Matched to CODIC IBL-I interior backplate. Dimensions: 66 x 242 x 79 mm External fitting with lever handle, right IBL-8304 stainless steel finish 19018304 1.273 372.00 IBL-8305 brass finish 19018305 1.200 372.00 IBL-8311 white (RAL 9016) 19018311 1.200 309.00 IBL-8399 spezial finish plus surcharge 19018399 1.200 on enquiry External fitting with lever handle, left IBL-9304 stainless steel finish 19019304 1.200 372.00 IBL-9305 brass finish 19019305 1.200 372.00 IBL-9311 white (RAL 9016) 19019311 1.200 309.00 IBL-9399 spezial finish plus surcharge 19019399 1.200 on enquiry IBL-A external backplate with electronic unit H External backplate with lever handle and electronic unit for management of access authorisations assigned with the aid of the CODIC HS-Soft software for CODIC CI-M manager keys, CI-G guest keys and CI-P personnel keys. Visual and audible signalling of authorised access, data transfer and low battery voltage. Automatic battery condition display after each data transfer operation. Rolling event history/audit trail storage for logging of the last 50 authorised access events, retrievable via CODIC SV-Soft. Matched to CODIC IBL-I interior backplate. Dimensions: 66 x 242 x 79 mm External fitting with lever handle, right IBL-8504 stainless steel finish 19018504 1.281 372.00 IBL-8505 brass finish 19018505 1.200 372.00 IBL-8511 white (RAL 9016) 19018511 1.283 309.00 IBL-8599 spezial finish plus surcharge 19018599 1.200 on enquiry External fitting with lever handle, left IBL-9504 stainless steel finish 19019504 1.200 372.00 IBL-9505 brass finish 19019505 1.200 372.00 IBL-9511 white (RAL 9016) 19019511 1.200 309.00 IBL-9599 spezial finish plus surcharge 19019599 1.200 on enquiry Security Systems 102 Prices subject to change without notice 04/08

CODIC IBL Interior Door Fittings Accessories IBL-I interior backplate Interior backplate with lever handle mounted in nylon bushing for 8 mm spindle. Matched to CODIC IBL-A external backplate, Dimensions: 50 x 224 x 64 mm Profile cylinder hole, follower-to-keyway centers: 72 mm IBL-I 204 stainless steel finish 19134204 0.260 117.00 IBL-I 205 brass finish 19134205 0.260 117.00 IBL-I 211 white (RAL 9016) 19134211 0.260 46.00 IBL-I 299 spezial finish plus surcharge 19134299 0.260 on enquiry without cylinder hole IBL-I 004 stainless steel finish 19135004 0.682 117.00 IBL-I 005 brass finish 19135005 0.690 117.00 IBL-I 011 white (RAL 9016) 19135011 0.672 46.00 IBL-I 099 spezial finish plus surcharge 19135099 0.700 on enquiry MS-IB installation set Installation set for CODIC IBL interior door fitting, consisting of mounting plate, 8 mm spindle with adapter follower, 8/9 spindle sleeve and 5 fixing screws for timber doors and also fixings for through-bolting of the CODIC IBL-I interior backplate with the IBL-A external backplate; various sets available for different door thicknesses as follows: MS-IB 1 32 145 mm 19167210 0.415 39.50 MS-IB 2 44 157 mm 19167220 0.426 39.50 MS-IB 3 56 169 mm 19167230 0.430 39.50 MS-IB 4 68 181 mm 19167240 0.450 39.50 MS-IB 5 80 193 mm 19167250 0.454 39.50 MS-IB 6 92 105 mm 19167260 0.469 39.50 EZ lockable cylinder insert Cylinder insert for CODIC IBL interior door fitting. EZ-11 keyed individually 19167211 0.014 8.60 EZ-12 keyed alike 19167212 0.014 8.60 SEZ key for lockable cylinder insert Key matched to the CODIC EZ lockable cylinder insert for the CODIC IBL interior door fitting. SEZ-11 keyed individually 19167221 0.016 2.30 SEZ-12 keyed alike 19167222 0.016 2.30 Security Systems 103 Prices subject to change without notice 04/08

CODIC IBL Wall models and control units for the IBL system UP-L concealed reader unit CODIC UP-L concealed reader for UP-M, UP-S, UP-H concealed control units in opposite wall installation. The voltage is supplied by the respective control unit. Visual and audible signalling of authorised access and programming mode in conjunction with UP concealed control unit. Dimensions incl. cover: 80 x 80 x 3 mm UP-L04 stainless steel finish 19247404 0.240 235.00 UP-L05 brass finish 19247405 0.248 235.00 UP-L11 white (RAL 9016) 19247411 0.196 197.00 UP-L99 special finish 19247499 on enquiry UP-H concealed control unit CODIC UP-H concealed control unit with floating activation of emergency escape locks with automatic locking action DORMA SVP, high-security jamb-concealed lock PROSIS, electric door openers, motor locks etc.. Activation by means of the concealed reader unit UP-L (to be ordered separately) installed in opposite wall. Management of issued access authorities for manager key CODIC CI-M, guest key CI-G and employee key CI-P with software CODIC HS-Soft. Visual and acoustic indication of authorised access and data transfer by the concealed reader unit. Rolling history storage to record the last 50 access events, retrievable via CODIC HS-Soft. Designed for combination with CODIC IBL door fittings within a single integrated system. Operating voltage: 12-36 V AC or 12-42 V DC / ± 10%, 100mA Dimensions incl. cover: 80 x 80 x 3 mm UP-H04 stainless steel finish 19341504 472.00 UP-H05 brass finish 19341505 472.00 UP-H11 white (RAL 9016) 19341511 0.240 432.00 UP-H99 special finish 19341599 on enquiry UP-ES concealed energy saving switch CODIC UP-ES concealed energy saving switch for the mechanical reception of CODIC hotel room keys. Insertion or removal of keys switches relay outputs on or off, e.g. for activation of all electric consumers in the room or as a presence signal. With one change-over contact set. Operating voltage: 24-230 V AC Contact rating: 250 V Max. continuing operating current: 8 A Installation: in concealed box dia. 65 mm Depth incl. mounting plate: 48 mm Cover: 80 x 80 mm, to be glued onto mounting plate UP-ES 04 stainless steel finish 19340504 0.275 70.50 UP-ES 05 brass finish 19340505 0.275 70.50 UP-ES 11 white (RAL 9016) 19340511 0.175 55.00 UP-ES 99 spezial finish plus surcharge 19340599 on enquiry Security Systems 104 Prices subject to change without notice 04/08

CODIC Software HS-SOFT version 2.0 hotel key management program CODIC HS-SOFT software for the management of electronically encoded CODIC CI-G hotel keys and for parameter setting of CODIC IBL-H hotel door fittings and UP-H concealed control units using a Windows platform. Lost, stolen or unreturned guest keys can be blocked. All keys overdue for return are indicated upon each program start. The rolling history storage of the last 50 access events at IBL-H fittings and UP-H concealed control units can be read with the CI-T transfer key. Automatic battery status query of IBL-H fittings upon each data transfer. The software can be updated / licensed for communication with various hotel management systems. All data are directly retrievable in HS-SOFT or are filed in a database readable by Microsoft Access 97. The access authorities can be distributed to up to 250 groups, each group having up to 100 doors. Number of keys: 6000 guest keys System requirements: IBM compatible PC (from Pentium II with 200 MHz onwards) with system software Windows 2000, XP, 3 1 / 2 disk drive, CD ROM drive, 32 MB RAM free hard disk capacity, 20 MB, a free serial interface RS 232 (for FIDELIO connection a 2nd serial interface RS 232 is required). Programming of keys via programming adapter at serial interface. Standard software package: 1 CD ROM 1 programming adapter 1 program key CODIC CI-PR, 1 time key CODIC CI-Z as well as 2 transfer keys CODIC CI-T. HS-Soft HS-Soft HS-Soft HS-Soft HS-Soft HS-Soft License: Grade 0 up to 40 doors, 25 manager or employee keys 19632200 0.250 576.00 License: Grade 1 up to 100 doors, 70 manager or employee keys 19632201 0.250 1,019.00 License: Grade 2 up to 300 doors, 130 manager or employee keys 19632202 0.250 1,526.00 License: Grade 3 up to 2000 doors, 200 manager or employee keys 19632203 0.250 2,034.00 License: FIDELIO interface combinable with all three grades 19632211 0.250 705.00 Presentation version: Limited to 2 doors, 1 door groups, 1 personnel key 19632209 0.250 87.00 Security Systems 105 Prices subject to change without notice 04/08

CODIC BT, BTL Electronic Accessories AMB battery set AMB alkali-manganese battery set for connection to the electronic unit of CODIC security door fittings. Service life: approx. 35,000 operating cycles with the CODIC ISE, IST and IS4-S electronic units, and approx. 25,000 operating cycles with the ISP electronic unit. Shelf life: approx. 3 years. Recommended for applications involving an average of more than 20 operating cycles per day. 19151000 0.085 30.50 LIB battery Set LIB lithium long-life battery set for connection to the electronic unit of CODIC security door fittings. Service life: approx. 45,000 operating cycles with the CODIC IST and IS4-S electronic units, and approx. 35,000 operating cycles with the ISP electronic unit. Shelf life: approx. 8 years. Recommended for applications involving an average of fewer than 20 operating cycles per day. 19152000 0.075 64.50 NCA rechargeable battery set NCA NiCd rechargeable battery set for connection to the electronic unit of CODIC security door fittings or to control units. The NCA battery is recharged via the switching unit or control unit concerned. The number of operating cycles and service life are dependent on the amount of charge in the battery. 19153000 0.020 64.50 Security Systems 106 Prices subject to change without notice 04/08

CODIC CC Key CI Key Accessories CC Key An electronically encoded chip key with factory-programmed code. Choice of unique keys and of identically coded keysets. CC-U unique key 19172219 0.008 17.50 CC-PR red programming key for IBL-M 19172215 0.008 21.50 CC-S3 set with 13 identical keys 19172222 0.022 49.50 CC-S6 set with 16 identical keys 19172224 0.050 98.50 CC-S12 set with 12 identical keys 19172226 0.116 198.00 CC-S20 set with 20 identical keys 19172228 0.152 330.00 Repeat order CODIC CC-S keys Security cards for recordering CC-S keys will only be issued for sets of 6 or more keys. It is therefore recommendable, when ordering smaller key sets, to include a sufficient number of spare keys right from the start. Prequisite for repeat orders of identical keys: Forwarding of the security card and one original key. net CC-N repeat order flat-rate charge 19999499 41.50 CI Key An electronically encoded chip key with unique key code and integrated read/write memory. CI-Z time key yellow 19173152 0.018 87.00 CI-T transfer key green 19173167 0.018 87.00 CI-M manager key black 19173129 0.018 48.50 CI-G guest key black 19173139 0.018 16.50 CI-P personnel key black 19173149 0.018 16.50 Security Systems 107 Prices subject to change without notice 04/08

DORMA Intruder Detection Systems EST detector for intruder alarm systems Deadbolt switching contact VdS* Class C No. G 101 153 Forced-entry detector for doors VdS* Class C No. G 101 145 Opening detector VdS* Class B No. G 101 540 Intruder detector with integrated door and deadbolt switching contact for false-alarm-free detection and alarm triggering in the event of attempted break-ins or actual break-in, with door and deadbolt position monitoring. Through the combination of the EST detector, an ESS security strike plate, a mechanical ESB at the top of the door and a monitored ESB at the bottom of the door on the pull (hinge) side, it is possible to create an intruder protection and alarm system which complies e.g. with German property insurance (VdS) requirements. Dimensions: 15 x 105 x 20 mm Switching capacity: max. 30 V DC, 100 ma Connecting cable: Length 4 m, 10-conductor, 6.5 mm dia. EST 19751104 0.380 128.00 *German association of property insurers ESS stainless steel security strike plate For combination with EST within an intruder security system. Non-handed. ESS 104 Standard security strike plate with latch retention ESS 304 Mounting plate for multi-point locks ESS 904 Concealed screw-fix retainer set 19753104 0.160 35.50 19753304 0.060 24.50 19753904 0.024 23.50 Security Systems 108 Prices subject to change without notice 04/08

DORMA Intruder Detection Systems ESF intruder protection and alarm system for Windows With rated braking point monitoring of the through-rod locking system, 20 mm rod projection, for connection to internal fittings with 7 mm square-section follower. For false-alarm-free detection and alarm triggering in the event of attempted break-ins or actual break-in. Registered with the VdS (German association of property insurers) as retrofit product. The system is composed of the individual components listed below: ESF 100 Basic set comprising a turn-and-tilt mechanism adapter and two fixing modules for the rods/covers and fixing material. 19721100 0.533 54.50 ESF 12x Lock case with monitoring PCB and shear bolts including connecting cable. Switching capacity: max. 30 V DC, 100 ma Connecting cable: Length 4 m, 4-conductor, 3.5 mm dia. ESF 120 with rightside cableing 19722120 0.220 43.50 ESF 121 with leftside cableing 19722121 0.215 43.50 (2 units required to complete the system) Rod set comprising through-rods, covers and lock case cover. Length: 1 x 1170 mm + 1 x 1170 mm ESF 711 white (RAL 9016) 19726711 1.996 75.50 Currently at the introductory stage; please enquire for actual availability and delivery dates! AM forced removal detector VdS Class C, No. G 194032 For the protection of valuables containers/cabinets, safes, weapons cabinets, vending/gambling machines, showcases, objets d art, window grilles etc. against unauthorized removal. Consisting of a spacer ring, PCB rated for breakage, tamper-monitored cover and 4 m of interconnecting cable. Can be installed using M 10 - M 16 (bolts). Dimensions: 35 x 25 x 45 mm Input current: max. 30 V DC, 100 ma Anti-tamper contact: max. 30 V DC, 100 ma (NC) AM 115 19730115 0.160 40.50 RK bolt monitoring contact German Association of Property Insurers VDS Class C, No. G 193 082, with a floating (no-volt) changeover contact for monitoring the locking status of doors Degree of protection: IP 68 Connecting cable: 4m LIYY 3 x 0.14 mm 2, Switching capacity: 30 V DC, 200 ma 15198000 0.120 37.00 Security Systems 109 Prices subject to change without notice 04/08

DORMA Intruder Detection Systems SLD heavy-duty anchor For securing the object (valuables container etc.) using a male thread. To be used together with the AM 115 forced removal detector for protection against unauthorized removal. SLD 31 M10/100 19733100 0.214 21.00 SLD 41 M12/100 19734100 0.334 29.00 SLD 51 M160/100 19735100 0.678 54.00 Sold in packs of 2 DBM 15 mm break-through detection stripping VdS Class C, No. G 190084 For monitoring vulnerable surfaces, with drill detection and small-tool reach-through monitoring in accordance with VdS requirements. Consisting of a fleece with meandering sewn-on double-standed wires. Distance between the wires: 15 mm Resistance: 18 Ohm/m 2 Power supply data: max. 48 V AC / DC Current consumption max.: 500 ma DBM 815 800 mm wide 19742815 0.210 130.00 DBM 515 500 mm wide 19742515 0.130 82.00 DBM 315 300 mm wide 19742315 0.080 50.00 DBM 215 200 mm wide 19742215 0.050 34.00 Minimum order: Max. supplied length: 1.0 m (in 10 cm increments) 25.0 m DGM 40 mm reach-through detection stripping VdS Class C, No. G 190084 For VdS-approved surface reach-through detection. Consisting of a fleece with meandering sewn-on double-standed wires. Distance between the wires: 40 mm Resistance: 7 Ohm/m 2 Power supply data: max. 48 V AC / DC Current consumption max.: 500 ma DGM 840 800 mm wide 19742840 0.150 81.50 DGM 540 500 mm wide 19742540 0.090 50.00 DGM 440 400 mm wide 19742440 0.070 42.00 DGM 340 300 mm wide 19742340 0.060 31.00 Minimum order: Max. supplied length: 1.0 m (in 10 cm increments) 25.0 m DSM 100 mm climb-through detection stripping VdS Class C, No. G 190084 For VdS-approved climb-through detection. Consisting of plastic netting with meandering sewn-on double standed wires. Distance between the wires: 100 mm Resistance: 3 Ohm/m 2 DSM 1000 1,000 mm wide 19741000 0.150 88.00 DSM 500 0 500 mm wide 19741500 0.080 44.00 Minimum order: Max. supplied length: 1.0 m (in 10 cm increments) 25.0 m Security Systems 110 Prices subject to change without notice 04/08

PROSIS Jamb-Concealed Locks and Accessories EZS 1 xxx, electro-mechanical high-security jamb-concealed lock Discontinued product lines Holding force: > 25 kn Class of protection: IP 40 Pierced for Europrofile cylinder Backset: 30 mm Lock case dimensions: 25 x 305 x 44.5 mm Forend: 32 x 375 x 3 mm Strike plate: 34 x 265 x 3 mm Input voltage 24 V DC; peak starting current 4 A EZS 1000 Fail-secure (open circuit): Power interruption causes the bolt to be thrown by spring action when door closed.holding current (unlocked): 0.4 A EZS 1100 Fail-safe (closed circuit): Power interruption causes the bolt to be retracted by spring action when door closed.holding current (locked): 0.4 A net 49100015 1.770 385.00 net 49110015 1.760 385.00 NT 24/4 power supply module for control cabinet installation Discontinued product lines Input voltage: 230 V AC ±10% Output: 24 V DC, 4.0 A, (stabilized) 12 V DC, 0.2 A (stabilized storage battery recharge control) Class of protection: IP 20 Dimensions: approx. 90 x 115 x 170 mm net 49912400 2.573 154.00 AP 3630 rechargeable battery pack Dimensions: 292 x 80 x 109 Power supply data: 36/24 V, 3 Ah Discontinued product lines 49913600 5.630 292.00 SRP 1 xxx protective rose Discontinued product lines SRP 104 stainless steel finish 49910104 0.530 147.00 SRP 103 dark brown 49910103 0.400 140.00 SRP 111 white (RAL 9016) 49910111 0.400 140.00 ASP drill protection armour Discontinued product lines 49910200 0.200 54.00 PROSIS cabling 2 x 1.5 and 4 x 0.22 (6.5 mm diameter) Discontinued product lines on enquiry Security Systems 111 Prices subject to change without notice 04/08

DORMA TEGO Glass TEGO Glass Fully glazed single-action swing door with 2 side screens and fanlight assembled with MANET single-point fixings. Hung on full-height pivot rod and mounted in floor pivot. DORMA CD 80 Design swing door operator with integrated locking or Push & Go function. Opening time, closing time and hold-open time adjustable. Opening angle min. 100. Power supply 230 V AC. Control column of transparent design for integration of functional components such as CODIC MasterCard, CODIC CARD etc. reader inserts of System 55 design, with frame-type trim. Clear door height 2,000 2,400 mm, clear door width 1000 mm (fixed), total width 1,800 3,500 mm, total height 2,400 3,000 mm, 12 mm toughened safety glass for door and side screens, fanlight 2 x 6 mm laminated safety glass. Operator set with locking device RH/ISO5 89000010 21.650 1,714.00 LH/ISO6 89000011 21.650 1,714.00 Operator set with Push & Go RH/ISO5 89000012 1,714.00 LH/ISO6 89000013 1,714.00 Fixings set RH/ISO5 89000020 8.960 915.00 LH/ISO6 89000021 8.960 915.00 Piezo radio remote control pushbutton incl. radio receiver Surface-mounted, self-adhesive, silver 89000040 0.172 246.00 white 89000041 0.175 246.00 anthracite 89000042 0.170 246.00 Operator control column Design Unequipped, 8 mm clear toughened safety glass 89000030 18.720 1,030.00 Operator column Design Basic price depending on model 89000031 19.050 1,030.00 Options 8 mm clear toughened safety glass Special glass design Without internal lighting (included in basic price) Perforated stainless steel tube, luminescent white/blue coating, 8 mm satin-finish toughened safety glass + 209.00 Perforated stainless steel tube, special luminescent colour coating, 8 mm satin-finish toughened safety glass + 275.00 Pushbutton + 55.00 CODIC MasterCard + 385.00 CODIC Card + 759.00 Special equipment option (depending on model) Trim frame/inserts white Trim frame/inserts silver Trim frames/inserts anthracite grey included in basic price Security Systems 112 Prices subject to change without notice 04/08

DORMA TEGO Glass Glass set 2 side screens, door, fanlight, 12 mm clear toughened safety glass including preparation - Minimum size * 1,540.00 - Maximum size * 2,365.00 Ceiling connection via wall abutment profile Wall connection - via wall abutment profile - with channel section, surface-mounted - with channel section, flush-mounted with floor pocket without floor pocket Installation and commissioning net Basic unit: TEGO Glass with CD 80 and activators 1,304.00 Commissioning of basic unit net TEGO Glass with CD 80 and activators 627.00 Surcharge for installation net Glass column 217.00 Surcharge for commissioning net Access control: CODIC MasterCard 146.00 * Minimum size 1,600 x 2,300 mm, maximum size 3,500 x 3,000 mm Security Systems 113 Prices subject to change without notice 04/08

DORMA TEGO Connect/Profile TEGO Connect TEGO Connect flush-mounted frame for installing all the components required for the door system (access control, emergency exit control, automation devices, door closer function etc.). L-section profiles. Increase in structural dimensions: Clear width + 160 mm and clear height + 125 mm. For doors of the following sizes: Door width mm; Door height.mm Wall type: ( ) Masonry/Brickwork 145 mm ( ) Stud wall 100 mm ( ) Masonry/Brickwork 270 mm ( ) Stud wall 150 mm TEGO Connect depending on package TEGO Frame TEGO Frame Professional 2-shell system frame prepared for installation of electric strike or SVP emergency escape lock, 2 KÜ cable loops, TV 500 emergency exit device, 230V power connection. Pre-machined for mounting automatic operator or door closer system. Architrave front 55 mm, architrave rear 70 mm. Sheet thickness 1.5 mm. Backbend front and rear 15 mm each. Rebate width 15 mm. Single rebate: ( ) Rebate depth 28.5 mm; ( ) Rebate depth mm Spacer rail bolted on to frame underside. Hollow chamber gasket, light grey. Levelling anchor fixings suitable for the above door dimensions. Hinge pocket BVX 11000 (VX 3-D) ( ) Galvanised and primed ( ) Powder coated to RAL ( ) Stainless steel finish TEGO Frame depending on package System solutions per TEGO versions 1-24 on application TEGO Basic Access Control (AC) functional package TEGO Basic AC functional package comprising the innovative CODIC MasterCard access control system. Operating on the basis of proximity ID cards and access codes, this technology sets new quality standards in the stand-alone access control segment. The CODIC MasterCard offers an optimum in flexibility. Access authorisations can be created, stored and edited in a matter of seconds using the programming card. Benefits: Attractive design down to the last detail; Easy installation in standard TEGO device box; 99 codes or cards, programmable at two levels; Illuminated keypad. Combination with other functional packages as per matrix. Scope of supply includes power supply unit and trims of required colour. Price discounts apply when combined with other function packages. TEGO Basic Access Control - Complete package - 89000101 637.00 Security Systems 114 Prices subject to change without notice 04/08

DORMA TEGO Connect/Profile TEGO Professional Access Control (AC) functional package TEGO Professional AC functional package. The ideal solution for meeting the elevated requirements that arise where large building complexes have to be managed with one system. It can handle 5000 users and enables up to 999 TEGO doors equipped with the Professional AC package to be effectively networked. Data integration with a control centre computer can be implemented even in networks with cable lengths of several kilometres. Access control with the CODIC Card can also be combined with a wide range of different actuators. The system directly controls the TEGO Mechatronic functional packages Electric Strike and SVP 2000 or 6000, and also the Closer/Operator functional packages. The system s capabilities are particularly apparent when combined with the Professional emergency exit control, as only a single module of the Professional AC package is required to achieve the full functional range required. This means additional savings in both time and cost. The up to 5000 users and the doors assigned to them can be arranged in easily manageable groups. ID cards or codes of equal authorisation levels are then allowed to access the same rooms and zones. Simple and efficient management of the access authorisations is ensured with the CC-Soft software package. Combination with other functional packages as per matrix. Scope of supply includes power supply unit and trims of required colour. Price discounts apply when combined with other function packages. TEGO Professional Access Control - Basic package - 89000102 1,033.00 If combined with the Professional Emergency Exit Control package 494.00 TEGO Basic Emergency Exit Control (EEC) functional package TEGO Basic EEC functional package in elegant System 55 design. The stand-alone flush-mounted emergency exit control ensures reliable operation of individual doors in cases where a network solution is not necessary or not possible. The basic system offering anti-tamper protection of emergency exits and escape routes (in accordance with German code DIBt 5/98) comprises an emergency escape pushbutton, keyswitch, control unit, power supply unit and door locking device. An emergency escape lock with automatic locking action can also be incorporated for ensuring door relocking to satisfy property insurance requirements. The emergency exit control can likewise be combined with the Basic Access Control package in order to add functions such as door open-time monitoring. Combination with other functional packages as per matrix. Scope of supply includes power supply unit and trims of required colour. Price discounts apply when combined with other function packages. TEGO Basic Emergency Exit Control - Complete package - 89000105 1,011.00 TEGO TMS Professional Emergency Exit Control With the TMS Professional EEC door management system, DORMA is able to offer a new dimension in the control of system components. The objective: ensuring reliable, problem-free door functions adapted to each specific situation from the simple stand-alone solution to networked doors connected to the building management system. The flexibility of the DORMA TMS door management system is such that it can also be combined with the Mechatronic and Closer/Operator functional packages as well as other systems such as intruder alarms, CCTV etc. Access control functionality is achieved by adding the Professional AC package. Here the TEGO really comes into its own in terms of cost benefit, as only the access reader is required from the Professional AC package. The DORMA TMS door management system also offers an extensive range of individualised solutions. Combination with other functional packages as per matrix. Scope of supply includes power supply unit and trims of required colour. Price discounts apply when combined with other function packages. TEGO TMS Professional Emergency Exit Control - Basic package - 89000106 1,374.00 Security Systems 115 Prices subject to change without notice 04/08

DORMA TEGO Connect/Profile Function package DORMA SVP 2000 emergency escape motor lock Mechatronic SVP 2000 emergency escape motor lock with automatic locking action. For automatic, powered unlocking of the TEGO door in conjunction with Access Control, Emergency Exit Control and Closer/Operator functional packages. Additional options for door status monitoring and assisted opening and closing in conjunction with the TMS Professional EEC functional package. Comprising electrically monitored SVP 2000 emergency escape lock with automatic locking action and featuring electric and mechanical sequential control, integrated anti-tamper detectors for monitoring latch, deadbolt and door status, connection cable SVP-A and cable loop KÜ 480. Price discounts apply when combined with other function packages. SVP 2000 emergency escape motor lock - Complete package - 89000115 1,264.00 Function package DORMA SVP 6000 switch-monitored emergency escape lock Mechatronic SVP 6000 AC switch-monitored emergency escape lock with automatic locking action. Authorisation to operate the door via the lever handle provided by access control (AC) functional packages. Additional possibilities for door status monitoring and assisted opening and closing in conjunction with the TMS Professional EEC functional package. Comprising electrically monitored SVP 6000 emergency escape lock with electrically engaged external lever handle and integrated anti-tamper detectors for monitoring latch, deadbolt and door status, connection cable SVP-A and cable loop KÜ 480. Combination with functional packages for access control and emergency exit control possible. Price discounts apply when combined with other function packages. SVP 6000 switch-monitored emergency escape lock - Complete package - 89000114 703.00 Function package DORMA SVP 4000 switch-monitored emergency escape lock Mechatronic SVP 4000 switch-monitored emergency escape lock with automatic locking action. For door status monitoring and assisted opening and closing in conjunction with the TMS Professional EEC functional package. Comprising electrically monitored microswitch lock SVP 4000 featuring integrated anti-tamper detectors for monitoring latch, deadbolt and door status, connecting cable SVP-A and cable loop KÜ 480. Combination with emergency exit control functional packages possible. Price discounts apply when combined with other function packages. SVP 4000 switch-monitored emergency escape lock with automatic locking action - Complete package - 89000110 362.00 Security Systems 116 Prices subject to change without notice 04/08

DORMA TEGO Connect/Profile Function package: DORMA TEGO Basic-R Standard electric strike Mechatronic: STANDARD electric strike comprising electric strike type Basic-R with adjustable latch, for over-rebated and flush-closing doors, non-handed, and TEGO strike plate. Combination with, for example, Access Control and Closer/Operator functional packages possible. TEGO Basic-R 89000111 Function package: DORMA TEGO Smoke electric strike (TEGO system test for smoke check applications in preparation). Mechatronic: SMOKE electric strike comprising electric strike type Smoke with adjustable latch, for over-rebated and flush-closing doors, non-handed, and TEGO strike plate. Combination with Access Control, Closer/Operator functional packages and others possible. TEGO Smoke 89000112 Function package: DORMA TEGO Fire 447 electric strike (TEGO system test for fire protection applications in preparation). Mechatronic: FIRE electric strike comprising electric strike type Fire 447 with adjustable latch, for over-rebated and flush-closing doors, non-handed, and TEGO strike plate. Combination with Access Control, Closer/Operator functional packages and others possible. TEGO Fire 447 89000113 Function package: DORMA TEGO standard mortise lock Door control: Standard lock. Selection of the most widely used DORMA locks suitable for TEGO Connect and TEGO Profile. Solutions incorporating mechatronic functional packages can also be provided to order. DORMA TEGO standard mortise lock 89000122 Function package: TEGO OGRO ZS door furniture and fittings Door control: Door furniture set A range of the most popular OGRO locks and furniture combinations has been compiled for integration with the TEGO Connect and TEGO Profile door systems. Solutions incorporating mechatronic functional packages can also be provided to order. TEGO OGRO ZS door furniture and fittings 89000120 depending on ES configuration depending on ES configuration depending on ES configuration depending on lock type depending on furniture type Function package: DORMA ITS 96 concealed door closer (for leaf thickness > 40 mm) Door control: ITS 96 closer integrated in door leaf. For assisted door closing. Closer and slide channel are of such compact design that they can be recessed in the door leaf and frame for almost total invisibility. The system also offers the reduced opening resistance typical of DORMA cam-action door closers as well as a wide range of functions. The DORMA ITS 96 is small enough to fit into all doors with leaf thicknesses of 40 mm or more; quality-assured with third-party verification. DORMA ITS 96 concealed door closer - Complete set - 89000131 252.00 Security Systems 117 Prices subject to change without notice 04/08

DORMA TEGO Connect/Profile Function package: DORMA TS 93 transom-integrated door closer Door control: TS 93 transom-integrated door closer The DORMA TS 93 offers exceptional opening ease. It is also a modular system, configurable to suit virtually any conceivable application profile, providing the ideal solution to doors in different situations and of different styles. Advanced, CAD-aided design and manufacture in assured quality mean guaranteed reliability and a long service life. Functional packages as per matrix. TS 93 transom-integrated door closer 89000132 235.00 Function package: CD 80 transom-integrated swing door operator Automatic: CD 80 transom-integrated swing door operator. For convenient, automatic opening of the door in combination with the Mechatronic functional packages Electric Strike or SVP 2000. Further combinations with the functional packages Access Control and Emergency Exit Control are possible. Suitable for walls > 150 mm thick. CD 80 integrated swing door operator 89000140 1,121.00 Security Systems 118 Prices subject to change without notice 04/08

DORMA Service for installers Order No. /each Parameterisation for TMS-CODIC CARD As per performance specification requirements Charged on a time + incidentals basis Price/hour net 56700101 96.50 Cable diagram for TMS/CODIC CARD systems As per performance specification requirements Charged on a time + incidentals basis Price/hour Wiring diagram for TMS/CODIC CARD As per performance specification requirements Charged on a time + incidentals basis Price/hour Support for installers by DORMA Service Repair work In the time from Monday to Friday, 7:00 hours 17:00 hours Charged on a time + incidentals basis Price/hour Standby service for repair work In the period from Monday to Friday, 17:00 h 21:00 h; Saturday 8:00 h 16.00 h Charged on a time + incidentals basis Price/hour Plus additional flat-rate charge of 88.00 Emergency repairs Response time following order receipt 12 24 hours; not available on Sundays and public holidays Charged on a time + incidentals basis Price/hour Commissioning Response time max. 14 days after advanced notification/order receipt Charged on a time + incidentals basis Price/hour Maintenance Response time per agreement Charged on a time + incidentals basis Price/hour net 56700102 96.50 net 56700103 96.50 net 56700113 68.00 net 56700111 68.00 net 56700112 136.00 net 56700120 68.00 net 56700130 68.00 Support for installers by the System and Project Management Price/hour net 56000340 136.00 All services charged on an hourly basis, plus travel, expenses and overnight accommodation where applicable. Security Systems 119 Prices subject to change without notice 04/08

DORMA Training courses for service personal Order No. /each. Advanced seminar: Emergency exit systems (min. 8 participants) 2-day group seminar for up to 16 people at DORMA HQ. The objective of the seminar is to transfer expert knowledge on the commissioning and maintenance of DORMA emergency exit systems in accordance with building regulations. Seminar contents: Bulletins issued by the Institute for Building Technology / EltVTR 05 98 Permissible modifications to fire doors and shutters Final examination with certificate for successful candidates Minimum participant qualifications: Electrotechnical training, knowledge of Windows programming software net Price/person 56700200 284.00 Advanced seminar: Emergency exit systems (min. 8 participants) One-day regional group seminar for up to 10 people, or as refresher seminar held at DORMA HQ for up to 20 people. The objective of the seminar is to transfer/extend expert knowledge on the commissioning and maintenance of DORMA emergency exit systems in accordance with building regulations. Seminar contents: Bulletins issued by the Institute for Building Technology / EltVTR 05 98 Permissible modifications to fire doors and shutters Final examination with certificate for successful candidates Minimum participant qualifications: Electrotechnical training, knowledge of Windows programming software Advanced seminar certificate for refresher seminar net Price/person 56700300 284.00 Intensive software training seminar for TMS-Soft (min. 8 participants) 1-day group seminar for up to 16 people at DORMA HQ. The objective of the seminar is to enable participants to plan, design and parameterise emergency exit systems as standalone and networked configurations. Notebook with TMS-Soft programming software + CC Soft included. Minimum participant qualifications: Electrotechnical training, knowledge of Windows programming software net Price/person 56700100 284.00 Access control software seminar for CODIC CARD-Soft (min. 8 participants) 1-day group seminar for up to 12 people at DORMA HQ. The objective of the seminar is to enable participants to plan, design and parameterise CODIC CARD access control systems as standalone and networked configurations. Notebook with TMS-Soft programming software necessary. Minimum participant qualifications: Electrotechnical training, knowledge of Windows programming software net Price/person 19999901 147.00 Access control software user seminar for CODIC CARD-Soft End-user seminar on operation of the CODIC CARD-Soft system and in particular the management of access authorisation rights. Minimum participant qualifications: Knowledge of Windows programming software net Price/hour 19999902 147.00 Price/day 19999903 725.00 Plus travel expenses and overnight accommodation where applicable. Access control software user seminar for CN-Soft-DCW End-user seminar on operation of the CN-Soft system and in particular the management of access authorisation rights. Minimum participant qualifications: Knowledge of Windows programming software net Price/hour 19999905 147.00 Price/day 19999906 725.00 Plus travel expenses and overnight accommodation where applicable. Security Systems 120 Prices subject to change without notice 04/08

DORMA Training courses for service personal Order No. /each. Access control software seminar for HS-Soft (min. 8 participants) 1-day group seminar for up to 12 people. The objective of the seminar is to enable the participants to plan, parameterise and implement access authorisation rights in relation to CODIC IBL security hotel door fittings using the HS-Soft system. Minimum participant qualifications: Electrotechnical training, knowledge of Windows programming software net Price/person 19999910 204.00 Access control software seminar for HS-Soft User seminar. The objective of the seminar is to enable the participants to plan, parameterise and implement access authorisation rights in relation to CODIC IBL security door fittings using the HS-Soft system for end users. Minimum participant qualifications: Knowledge of Windows programming software net Price/hour 19999911 147.00 Price/day 19999912 725.00 Plus travel expenses and overnight accommodation where applicable. Security Systems 121 Prices subject to change without notice 04/08

Security Systems Demonstration Aids for Retailers CODIC DB-B demonstration stands CODIC DB-B demonstration stands comprising acrylic glass upright with mounted SVP lock and IBL-I 005 internal backplate with mock stainless steel finish. Prepared for installation and demonstration of internal door fittings of the type IBL or XS. Accessories such as mortice lock, assembly wrench and batteries included in the standard equipment. The relevant mock stainless steel IBL or XS fittings and the appropriate ID fobs/cards/media to complete the demonstration package must be ordered separately. DB-B 19911805 5.850 310.00 net DB-XSC display stand DORMA DB-XSC presentation stand comprising timber assembly with installed mortise lock. Prepared for mounting an XS cylinder for presentation purposes. XS components required to complete the display should be ordered separately. In packs of 1 net DB-XSC display stand 19911900 0.650 44.00 CODIC MH-BI drilling jig For the installation of CODIC IBL or XS interior door fittings. Including centring pins for profile and round cylinders and 7, 8 and 9 mm followers. net 19191400 1.000 74.50 Security Systems 122 Prices subject to change without notice 04/08

Security Systems Demonstration Aids for Retailers SVP 6000 demo unit Plastic-coated timber demo unit with SVP 6000 emergency escape lock for access control applications, and OGRO lever handle set. System 55 switch for disengaging the external lever handle. Disappearing carry handle. Can be integrated in the DORMA Point of Sale exhibition system for installers and retailers. Power supply: 230 V AC Dimensions (W x H x D): 25 x 40 x 20 cm net 16500000900 484.00 Electric strike demo unit Plastic-coated timber demo unit with a Basic electric strike and the Easy Adapt latch guide. System 55 switch for actuation of the electric strike. Fire-rated and smoke-rated electric strikes with strike plates also provided as additional specimens with no power supply. Disappearing carry handle. Can be integrated in the DORMA Point of Sale exhibition system for installers and retailers. Power supply: 230 V AC Dimensions (W x H x D): 25 x 40 x 20 cm net 16500000901 429.00 STA demo door Plastic-coated timber demo unit as demo door with DORMA TMS door management system, SVP 2000 motor lock, electronic exit bolt/keep, OGRO lever handle set and OGRO hinges. Connection of the TL-G demo unit via Cat5 patch cable for enabling the locking devices. Disappearing carry handle. Can be integrated in the DORMA Point of Sale exhibition system for installers and retailers. Power supply: 230 V AC Dimensions (W x H x D): 55 x 40 x 20 cm net 16500000902 1,623.00 TL-G demo unit Plastic-coated timber demo unit with TL-G door terminal unit for activation of the STA demo door via Cat5 patch cable. Disappearing carry handle. Can be integrated in the DORMA Point of Sale exhibition system for installers and retailers. Dimensions (W x H x D): 25 x 40 x 20 cm net 16500000903 374.00 Design terminal demo unit Plastic-coated timber demo unit with Design flush-mounted terminal. Emergency pushbutton, keyswitch and CODIC keypad reader in System 55 design. Actuation of the STA demo door via Cat5 patch cable. Disappearing carry handle. Can be integrated in the DORMA Point of Sale exhibition system for installers and retailers. Dimensions (W x H x D): 25 x 40 x 20 cm net 16500000904 440.00 JUNG ES stainless steel Design terminal demo unit Plastic-coated timber demo unit with Design flush-mounted terminal. Emergency pushbutton, keyswitch corresponding to the JUNG ES stainless steel system. Actuation of the STA demo door via Cat5 patch cable. Disappearing carry handle. Can be integrated in the DORMA Point of Sale exhibition system for installers and retailers. Dimensions (W x H x D): 25 x 40 x 20 cm net 16500000905 462.00 Security Systems 123 Prices subject to change without notice 04/08

Security Systems Demonstration Aids for Retailers SVP accessories demo unit Plastic-coated timber demo unit with cable loop, bolt monitoring contact, SVP strike plate and HZ inactive leaf locking device. Disappearing carry handle. Can be integrated in the DORMA Point of Sale exhibition system for installers and retailers. Dimensions (W x H x D): 25 x 40 x 20 cm net 16500000906 275.00 XS demo unit Plastic-coated timber demo unit with XS cylinder and XS fitting in combination with mortise locks. Disappearing carry handle. Can be integrated in the DORMA Point of Sale exhibition system for installers and retailers. Dimensions (W x H x D): 25 x 40 x 20 cm net 16500000907 715.00 CODIC MasterCard demo unit Plastic-coated timber demo unit with CODIC MasterCard keypad reader and electric strike. Disappearing carry handle. Can be integrated in the DORMA Point of Sale exhibition system for installers and retailers. Power supply: 230 V AC Dimensions (W x H x D): 25 x 40 x 20 cm net 16500000908 418.00 Carry bag for demo units Resilient carry bag for demo units, padded with shoulder strap and cable pouch. 16500000910 on enquiry Security Systems 124 Prices subject to change without notice 04/08