PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Similar documents
Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

80 Watts FLANGE FINISH

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

USAI. BeveLED BLOCK Dimming Compatibility. Lighting River Road New Windsor, NY

USAI ADJUSTABLE. Lighting

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

OPTIONAL LENS 2 FLANGE FINISH

PROJECT INFORMATION PROJECT

USAI. Basic Dimming Compatibility. BeveLED Mini. Lighting. Precision Lighting. Color Harmony River Road New Windsor, NY 12553

PROJECT INFORMATION PROJECT DATE TYPE

PROJECT DATE TYPE. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

1" Regress Trim DELIVERED PERFORMANCE - Downlight

PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

PROJECT INFORMATION FLANGE FINISH

PROJECT INFORMATION LENS. S Solite F Frosted C Clear N No Glass. New Construction CP Chicago Plenum 35KS 3500K, 80+ CRI.

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

DATE TYPE 40 DELIVERED PERFORMANCE

BeveLED 2.1 PROJECT INFORMATION

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

PROJECT INFORMATION PROJECT DATE TYPE

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

SliverLED Round Adjustable, Wet Location SR21W

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts ADJUSTABLE

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN25RDT - BM- MTG214-27KS LSP55-120V - DIML2 - CB27 - BOFC COLOR

SliverLED Round Downlight, 1 Regress SR11

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN10RAT - BM- MTG214-27KS LNC61-120V - DIML2 - CB27 - BOFD

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts

NanoLED NXT Cylinder LNRP3 Surface

Field changeable between Trimmed / Trimless / Millwork

True Zero Conceal - Z3SA-C 3 Square Adjustable

PROJECT DATE LENS. S Solite (provided standard) F Frosted. S Solite (provided standard) F Frosted HOUSING TYPE REFLECTOR

Field changeable between Trimmed / Trimless / Millwork

BeveLED. 2.2 Retrofit 4.5 Round Downlight - B4RDRT B4RDRT. usailighting.com/beveledrt

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

BeveLED Cylinder LBRP6 Surface

ARMSTRONG INTERSECTION DOWNLIGHTING KIT

BeveLED Cylinder LBRP6 Pendant

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

Field Convertible from Trimless or Millwork to Trimmed. Trimmed - B3SCF Trimless - B3SCL Millwork - B3SCM

BeveLED Mini - B3SD 3 Square Downlight

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

Deep Regress - B4RC usailighting.com/b4rc LED COLOR CHOICES. Classic White

Nova NFTV (0-10V)* 100%-10% 1-30 ** 1-30* Nova T NTFTV (0-10V)* 100%-10% 1-30 ** 1-30* Lutron ZT. Diva DVTV (0-10V)* 100%-10% 1-30 ** 1-30* Standard

BeveLED Mini Trimless Acoustical - B3RDP

BeveLED Mini - B3RD 3 Round Downlight

Universal and Field Convertible - Trim Trimless Millwork. Downlight - B4SD usailighting.com/b4sd LED COLOR CHOICES. Classic White

PROJECT DATE FLANGE FINISH

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

BeveLED Mini - B3RA 3 Round Adjustable

IHOL-6DR / IRD600 6 Gravity LED Downlight

IHOL-4DR / IRD400 4 Gravity LED Downlight

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

RFP Grand Entry Canopies Addendum 002 Issued July 16, 2013

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke Round Adjustable C3

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Adjustable HP

Evoke 2.9" HP. 2.9" Square Downlight

Classix 6" 6" Round Adjustable C3

Grüv Flare Regressed. Recessed Linear LED

Evoke Square Downlight

Classix 6" 6" Round Adjustable C3M

Evoke Square Adjustable HP

Evoke Square Adjustable C3M

Evoke Square Downlight

Hornet HP. Square Glass Downlight

Hornet HP. Semi-Recessed 4-Light Square Multiple

Evoke Square Downlight

Velato. Recessed Slot Adjustable Multiples

Micro Wall Wash Trimless - MWL

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Classix 6" 6" Round Lens Wall Wash

Hornet HP. Round Glass Downlight

Evoke Round Downlight

Grüv Flare Regressed. Recessed Linear LED

Essenza. Square Downlights

Essenza. Round Downlights

Transcription:

BeveLED 2.1 Trimless PROJECT INFORMATION PROJECT WALL WASH 3454 DATE TYPE 6000K, Full On 100% 3500K, Dimmed to 50% 2450K, Dimmed to 75% Color Select Trimless Recessed Wall Wash - Independent color temperature and intensity control for LED lighting. Color Select represents the next innovation in color temperature control for advanced LED recessed downlighting. Color Select products allow users to adjust color temperature from 6000K down to 2200K while independently adjusting intensity to achieve ultimate control over the quality of light in a space with a single fixture type. Color Select interfaces with standard dimming and control systems. DELIVERED PERFORMANCE BeveLED2.1 2200K 2700K 3000K 3500K 4000K 4500K 5000K 5500K 6000K Color Select Wall Wash Delivered Lumens Per Watt 42 47 49 51 53 54 54 57 57 Source Lumens 1100 1200 1250 1300 1375 1375 1400 1450 1475 Delivered Lumens 600 675 700 750 775 775 800 825 825 Delivered Lumens Per Watt 34 37 39 41 43 43 44 45 46 Source Lumens 1825 2000 2075 2175 2275 2300 2350 2425 2450 Delivered Lumens 1025 1125 1175 1225 1275 1300 1325 1350 1375 HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: Example : 3454W - B1-10 - LRLW4-6016 - CSD1-6022KS - NC - 120V - DIML3-010V - CB27 TRIM ORDERING INFORMATION 16W 32W TRIM OPTION 3454 BEVEL STYLE B1 BEVEL FINISH LUMEN AND KELVIN TUNING WITH 3454 Square Trimless Wall Wash W Wet location 1 1 Wet location, use with B1 trims only. B1 1 Regress Bevel, Painted Die Cast AB1 1 Regress Bevel, Black Anodized Finish AC1 1 Regress Bevel, Clear Matte Anodized Finish 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles) HOUSING ORDERING INFORMATION HOUSING ENGINE CODE WATTAGE CODE COLOR LSLW4 CSD1 6022KS HOUSING TYPE VOLTAGE DIMMING DRIVER OPTIONS COLOR ACCESSORIES 010V LSLW4 6016 16W LED, 800 lumens 6032 32W LED, 1325 lumens CSD1 6022KS 6000K-2200K NC New Construction CP Chicago Plenum 2 Tunable IC Insulation-Contact White Light Rated / Airtight 2 80+ CRI 2 Not available with EM 120V 277V DIML2 0-10V dim, 10% (provided standard) DIML3 Lutron Hi-Lume 1% 2-wire, 120V only DIML4 Lutron Hi-Lume 1% 3-wire/ECO DIML6A EldoLED 0-10V, 0.1%, logarithmic / Lutron controls DIML6B EldoLED 0-10V, 0.1%, linear controls DIML6E EldoLED 0-10V, 1%, logarithmic/lutron controls DIML6F EldoLED 0-10V, 1%, linear controls DIML7 EldoLED DALI, 0.1% 010V 0-10V signal transitions color temperature from 6000K to 2200K CB27 27 C-Channel Bars CB52 52 C-Channel Bars EML Emergency battery 3 EMLW Emergency battery, wet location 3 MLXX Millwork adapter 4 XX=Specify Color (10, 13, 21, 28, RAL) Millwork not wet listed 3 Not for use with IC or CP housings. 2013., LLC. Revised 08/18/2016

BeveLED 2.1 TRIM INFORMATION WALL WASH 3454 2.1 Trimless Bevel Finish 4 1 2" x 4 1 2" HOUSING INFORMATION New Construction Universal Style Housing - NC Chicago Plenum (16W) - CP IC / Airtight (16W) - IC Chicago Plenum (32W) - CP IC / Airtight (32W) - IC New Construction w/ Emergency - EM 7 3 /8" 7 3 /8" 8 1 /2" 8 9 /16" 7" 5 /8"-1" 7" 5 /8"-1" 7" 5 /8"-1" 7" 5 /8-1 13" 13" 13" 13" 18 5 /8" (Plan View) 22 1 /8" (Plan View) 18 5 /8" (Plan View) 22 1 /8" (Plan View) 18 5 /8" (Plan View) 22 1 /8" (Plan View) 18 5 /8" (Plan View) 22 1 /8" (Plan View) SPECIFICATIONS TRIM: 4-1/2" square aperture with a 1" regressed bevel retained by four mounting clips. Die cast aluminum bevel is available in white, statuary bronze, black, and metalized grey finishes. Also available in black anodized or clear matte anodized bevel. Custom color trims available (provide RAL#). TRIM LENS: Trim is shipped with micro diffusion wall wash lens. REFLECTOR: Proprietary precision injection molded wall wash reflector. COLOR : Patented tunable white light transitions color temperature from 6000K to 2200K from a 0-10V signal. DIMMING OPTIONS: Multiple dimming drivers available. See compatibility chart attached. Some on-time delay may be experienced, depending on control system used. Note: DIML6A and DIML6E logarithmic control are intended for use with Lutron control systems; DIML6B and 6F linear control are intended for use with non-lutron controls. DIML6 dimming drivers source 2mA. ADJUSTMENT: 362 horizontal locking in 90 increments. EMERGENCY: Emergency lighting battery pack with remote test switch is serviceable through aperture. EMLW wet FIELD REPLACEABLE LIGHT ENGINE: Available in 2 lumen location option is available with B1 trim only and requires packages: 16W and 32W. Engine is field replaceable through remote test switch. Bodine BSL17C provides 200mA for 90 the aperture without tools. minutes. EM option is available with NC housings only. RATED LIFE: Based on IESNA LM80-2008 50,000 hours at 70% lumen maintenance (L70). THERMAL MANAGEMENT: Proprietary high performance aluminum die cast heatsink for maximum LED life. Ambient temperatures at fixture location should not exceed 40 C during normal operation. FIELD REPLACEABLE DIMMING DRIVER: 0-10V, 100%-10% DIML2 solid state electronic constant current driver with a high power factor provided standard and sources 2mA. Specify 120V or 277V. Driver complies with IEEE C62.41 surge protection. HOUSING: All-Ways Square (covered by US Pat. No: US 7,832,889) housing allows alignment of square aperture (up to 20 rotation) after housing installation and prior to finish ceiling installation. Fabricated of 20 ga. galvanized steel with thru wire J-box, 4 in 4 out at min. 90 C, #12 AWG thru branch circuit wiring. MOUNTING: Butterfly brackets and adjustable nailer bars with integral nails provided. Nailer bars are extendible from 14 to 24 centers. MAXIMUM CEILING THICKNESS: As per drawings above. Millwork for 1" maximum wood. CEILING CUT OUT: Millwork: 4-13/16" x 4-13/16" All others: 5-1/2" x 5-1/2" LISTINGS: Dry/Damp. Millwork for dry/damp only. Wet location option available with B1 trim only. NRTL/CSA-US tested to UL standards. IBEW union made. WARRANTY: 5 years NOTES: Not for use in corrosive environment. Use of pressure washer voids warranty. For interior use only Not for use with acoustical ceilings. Trimless for drywall installation only Millwork option for non-spackle installations Consult factory for video capture applications. PHOTOMETRICS: Consult factory or website for IES files. Tested in accordance with IESNA LM79-2008. 2013., LLC. Revised 08/18/2016

DIML2 STANDARD DRIVER STANDARD DRIVER: 0-10V Intensity Dimming Driver Wiring (Dims down to 10%) NOTE: Consult dimmer manufacturer for detailed installation information. For use with 0-10V type controls. Use only with approved vendor models in table below J-BOX WIRING FOR STANDARD DRIVER NOTE: DRIVER SOURCES 2mA REFER TO DIMMER MANUFACTURER FOR MAX LOAD 0-10V LED DRIVER PURPLE - GRAY - PURPLE / ORANGE (+) GND GRAY - PURPLE - NOTE: COLOR LER SOURCES 2mA - DIML2 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V / 277V Use source current per Crestron ilux dimmer expansion module CLS-EXP-DIMFLV 100% - 10% fixture specification Crestron DIN Rail dimmer DIN-4DIMFLV4 100% - 10% sheet to determine Crestron DIN Rail analog output module DIN-A08 100% - 10% number of fixtures per Crestron 8 Channel dimmer module GLX-DIMFLV8 100% - 10% dimmer. Max number Crestron 8 Channel dimmer module GLXP-DIMFLV8 100% - 10% of fixtures is limited by Leviton IllumaTech dimmer IP710-DLX 100% - 10% dimmer load rating. Lightolier (Philips) Vega V2000FAMU 100% - 10% Lutron Diva DVTV-XX 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. 2014., LLC. I2-228-2 Revised 09/26/2016

DIML3 DIML3 LED: Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / LED Dimming Driver Wiring (Dims down to 1%) 120V only. J-BOX WIRING FOR DIML3 LUTRON HI - LUME A SERIES DRIVER 2 WIRE GREEN - GND GROUND PURPLE / ORANGE (+) NOTE: COLOR LER SOURCES 2mA DIML3 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Dimmer* Manufacturer Product Part Number Output Range Typical High Wattage 120V Only 40W and Less 41W - 80W ETC Sensor+ Cabinet ELV10 100% - 1% 1 26 1 13 ETC Unison DRd Cabinet ELV10 100% - 1% 1 26 1 13 Lutron Maestro Wireless dimmer MRF2-6ND-120-100% - 1% 1 8 1 4 Lutron HomeWorks QS adaptive dimmer HQRD-6NA- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 60W dimmer HQRD-6ND- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 1000 W dimmer HQRD-10ND- 100% - 1% 1 13 1 6 Lutron Stanza dimmer SZ-6ND- 100% - 1% 1 8 1 4 Lutron RadioRA 2 adaptive dimmer RRD-6NA- 100% - 1% 1 8 1 4 Lutron RadioRA 2 1000 W dimmer RRD-10ND- 100% - 1% 1 13 1 6 Lutron HomeWorks QS wallbox power module HQRJ-WPM-6D-120-100% - 1% 1 26 1 13 Lutron HomeWorks wallbox power module HWI-WPM-6D-120 100% - 1% 1 26 1 13 Lutron GRAFIK Eye QS control unit QSGR-, QSGRJ- 100% - 1% 1 26 1 13 Lutron GRAFIK Eye 3000 control unit GRX-3100-, GRX-3500-100% - 1% 1 26 1 13 Lutron RPM-4U module HW-RPM-4U-120, LP-RPM-4U-120 100% - 1% 1 26 1 13 Lutron RPM-4A module HW-RPM-4A-120, LP-RPM-4A-120 100% - 1% 1 26 1 13 Lutron GP dimming panels Various 100% - 1% 1 26 1 13 Lutron Ariadni CL 250W dimmer AYCL-253P- 100%-1% 1 8 1 4 Lutron Diva CL 250W dimmer DVCL-253P-, DVSCCL-253P- 100%-1% 1 8 1 4 Lutron Grafik T CL or RF CL dimmer GT-250M-, GTJ-250M- 100%-1% 1 8 1 4 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. 2014., LLC. I2-228-3 Revised 09/26/2016

DIML4 DIML4 LED: Lutron Hi-Lume A-Series LED Driver with Eco System Control / LED Dimming Driver Wiring (Dims down to 1%) J-BOX WIRING FOR DIML4 LUTRON HI - LUME A SERIES DRIVER 3 WIRE & ECOSYS PURPLE / ORANGE (+) NOTE: COLOR LER SOURCES 2mA GREEN - GND BLACK - LINE ORANGE - HOT DIMMING PURPLE GRAY- ECOSYS ONLY PURPLE - ECOSYS ONLY ECO-SYS BUS PURPLE - ECOSYS ONLY (CAP OFF FOR 3-WIRE) PURPLE GRAY- ECOSYS ONLY (CAP OFF FOR 3-WIRE) ORANGE - HOT DIMMING (CAP OFF FOR ECOSYS) BLACK - LINE GROUND Note: For 3-wire controls, cap off purple and purple/gray wires. For EcoSyS Controls, cap off orange wire. DIML4 3-Wire Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Typical High Wattage 120V Only 40W and Less 41W - 80W ETC Sensor+ Cabinet D20 Dimming module 100% - 1% 153 126 ETC Unison DRd Cabinet D20F Dimming module 100% - 1% 153 126 Lutron Nova T NTF-10-100%1% 141 1 20 Lutron Nova T NTF-103P- 100%1% 120 1 10 Lutron Nova NF-10-100%1% 141 1 20 Lutron Nova NF-103P- 100%1% 120 1 10 Lutron Vareo VF-10-100%1% 120 1 10 Lutron Skylark SF-10P-, SF-103P- 100%1% 120 1 10 Lutron Diva DVF-103P-, DVSCF-103P- 100%1% 120 1 10 Lutron Ariadni AYF-103P- 100%1% 120 1 10 Lutron Vierti VTF-6A- 100%1% 115 1 7 Lutron Maestro MAF-6AM-, MSCF-6AM- 100%1% 115 1 7 Lutron Maestro Wireless MRF2-F6AN-DV- 100%1% 115 1 7 Lutron RadioTouch RTA-RX-F- 100%1% 141 1 20 Lutron Spacer System SPSF-6A-, SPSF-6AM- 100%1% 115 1 7 Lutron Lyneo Lx LXF-103PL- 100%1% 120 1 10 Lutron RadioRA 2 RRD-F6AN-DV- 100%1% 115 1 7 Lutron HomeWorks QS HQRD-F6AN-DV 100%1% 115 1 7 Lutron Interfaces PHPM-3F-120, PHPM-3F-DV, GRX-FDBI-16A 100%1% 141 1 20 Lutron GP Dimming Panels Various 100%1% 141 1 20 277V Only 40W and Less 41W - 80W ETC Sensor+ Cabinet D20 Dimming module 100% - 1% 153 126 ETC Unison DRd Cabinet D20F Dimming module 100% - 1% 153 126 Lutron Nova T NTF-10-277- 100%1% 144 1 22 Lutron Nova T NTF-103P-277-100%1% 133 1 16 Lutron Nova NF-10-277- 100%1% 144 1 22 Lutron Nova NF-103P-277-100%1% 133 1 16 Lutron Skylark SF-12P-277-, SF-12P-277-3 100%1% 133 1 16 Lutron Diva DVF-103P-277-, DVSCF-103P-277-100%1% 133 1 16 Lutron Ariadni AYF-103P-277-100%1% 144 1 22 Lutron Vierti VTF-6A- 100%1% 133 1 16 Lutron Maestro MAF-6AM-277-, MSCF-6AM-277-100%1% 120 1 10 Lutron Maestro Wireless MRF2-F6AN-DV- 100%1% 133 1 16 Lutron RadioTouch RTA-RX-F- 100%1% 188 1 44 Lutron Spacer System SPSF-6A-277-, SPSF-6AM-277-100%1% 120 1 10 Lutron Lyneo Lx LXF-103PL-277-100%1% 133 1 16 Lutron RadioRA 2 RRD-F6AN-DV- 100%1% 133 1 16 Lutron HomeWorks QS HQRD-F6AN-DV 100%1% 133 1 16 Lutron Interfaces PHPM-3F-DV, GRX-FDBI-16A 100%1% 188 1 44 Lutron GP Dimming Panels Various 100%1% 188 1 44 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. 2014., LLC. I2-228-4 Revised 09/26/2016

DIML4 Continued DIML4 LED: Lutron Hi-Lume A-Series LED Driver with Eco System Control / LED Dimming Driver Wiring (Dims down to 1%) J-BOX WIRING FOR DIML4 DIML4 LED: Lutron Hi-Lume A-Series LED Driver with Eco System Control / LED Dimming Driver Wiring (Dims down to 1%) DIML4 3-Wire Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Typical High Wattage 120V / 277V 40W and Less 41W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 100%1% 132 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 100%1% 164 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 100%1% 164 1 32 Lutron Quantum Various 100%1% 164 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. 2014., LLC. I2-228-4 Revised 09/26/2016

DIML6A & 6B DIML6A LED: eldoled SOLOdrive 561/S 0-10V control dimming driver For Lutron Controls. (dims down to 0.1%) DIML6B LED: eldoled SOLOdrive 561/S 0-10V control dimming driver For Non-Lutron Controls. (dims down to 0.1%) J-BOX WIRING FOR DIML6 NOTE: DRIVER SOURCES 2mA REFER TO DIMMER MANUFACTURE FOR MAX LOAD 0-10V LED DRIVER PURPLE - GRAY - GREEN - GND PURPLE / ORANGE (+) GROUND GRAY - PURPLE - NOTE: COLOR LER SOURCES 2mA DIML6A LED: EldoLED SOLOdrive 561/S 0-10V control 100%-0.1% linear-programmed dimming driver for use with logarithmic-style controls (e.g., Lutron and others listed in the table below) DIML6A Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V Refer to manufacturer's Lutron Diva DVTV/NFTV/NTFTV with PP-20 99% - 0.1% dimmer load rating for Lutron Energi Savr Node QSN-4T16-S 100% - 0.1% maximum and minimum Lutron GP Dimming Panels TVM2 Module 99% - 0.1% fixture quantities per Lutron Interfaces GRX-TVI w/ GRX3503 100% - 0.1% dimmer. Sensor Switch nio nio EZ 100% - 0.1% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML6B LED: EldoLED DIMMER: 0-10V SOLOdrive 561/S 0-10V control 100%-0.1% logarithmic-programmed dimming driver for use with linear-style controls (e.g., Crestron, non-lutron, and others listed in the table below) 0-10V (-) GRAY DIML6B Dimmer Compatibility Chart LED 0-10V (+) PURPLE V+ RED Dimmed Light Qty Fixtures Manufacturer 120V & 277V Product SWITCHED HOT NEUTRAL SWITCHED Part HOTNumber WHITE DRIVER V- BLACK Output Range Per Dimmer* Refer to Bush-Jaeger Electronic potentiometer GREEN 2112U-101 100% - 0.1% manufacturer's Jung Electronic potentiometer GND 240-10 100% - 0.1% dimmer load rating Leviton CLASS 2 WIRES IllumaTech dimmer IP710-DLX 100% - 0.1% for maximum and Lightolier LINE (Philips) Momentum (120V ONLY) ZP600FAM120 100% - 0.1% minimum fixture RELAY Merten Electronic potentiometer 5729 100% - 0.1% quantities per Pass & Seymour Titan DIML6A, CD4FB-W 6B 100% - 0.1% dimmer. NEUTRAL Watt Stopper Miro 0-10V DIMMING W/RELAY DCLV1 TO SWITCH POWER 100% - 0.1% Synergy Wallbox Dimmers ISD BC 100% - 0.1% ABB i-bus SD/S 2.16.1 100% - 0.1% Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 100% - 0.1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8-100% - 0.1% Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 100% - 0.1% Crestron DIN Rail Analog Output Module DIN-A08 100% - 0.1% Crestron DIN Rail 0-10V Fluorescent Dimmer DIN-4DIMFLV4 100% - 0.1% Crestron ilux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV 100% - 0.1% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. 2014., LLC. I2-228-6 Revised 09/26/2016

DIML7 DIML7 LED: eldoled DALI dimming driver (dims down to 0.1%) J-BOX WIRING FOR DIML7 0-10V LED DRIVER ORANGE / WHITE (+) DALI ORANGE (-) DALI GREEN - GND PURPLE / ORANGE (+) NOTE: COLOR LER SOURCES 2mA GROUND ORANGE (-) DALI ORANGE / WHITE (+) DALI NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. 2014., LLC. I2-228-7 Revised 09/26/2016