Europa Shower Cabinet

Similar documents
INSTALLTION MANUAL FOR M-A6012

Installation Instruction of AM168 TS-series Control panel

INSTALLTION MANUAL FOR M-A011

Installation Instruction of AM124ETL-L TS-series Control panel

Installation Manual for M-G014 & M-G015

Installation and Operation Manual

Massage Bathtub Instructions of Installation. MODEL:MT-RT1708 SIZE:1700*800*620mm

Massage Bathtub Instructions of Installation. MODEL: TOCOA SIZE: 1380*1380*610mm

Preparations MT-RT1806. Cleaning & Maintenance. Precautions

Massage Bathtub Instructions of Installation. MODEL:MT-NR1502(1504) SIZE:1500*1500*610mm

No advanced advice will be submit before we change our design and size. The pictures may be a little different from the real products.

AQUAPEUTICS MONACO INSTALLATION MANUAL

No advanced advice will be submit before we change our design and size. The pictures may be a little different from the real products.

STEAM ROOM with TUB. Installation & Operation Manual MK547

INSTALLATION AND USER MANUAL

User manual Whirlpool

CONTEMPORARY STEAM ROOM

Steam Room Installation Manual L52 Series (L528) All set up dimensions are in Millimeters

Packing list. Packing 1. Packing 2. Packing 3. Spare parts list

LEVENS STEAM SHOWER ENCLOSURE

Massage Bathtub. Instructions of installation and usage. Instructions of Installation and Use TLP-632. Cleaning&Maintenance

INSTRUCTION SHOWER CABIN ILMA 901

FREWIN STEAM SHOWER ENCLOSURE

Install manual. Self-clean system. Steam bathroom MODEL : WS-501

ARLEY STEAM SHOWER ENCLOSURE

NEPTUNE Steam Room Installation Instructions

M-K STEAM ROOM

AM 213 Installation Introduction

Your best choice! STEAM BATHROOM MODEL : WS-902A WS-902B. No advanced advice will be submit before we change our design and size.

Massage Bathtub. Instructions of Installation and Use. Preparations MT-RT1804. Cleaning & Maintaining

USER MANUAL OF KL8300 SYSTEM

I. U881 Series Structure...1 II. Security Advice...2 III. Technical Parameter...3 IV. Install U881 Sauna Room V. Electricity Supply And Water

Sanitary Ware Expert Your best choice!

900mm Island Canopy Manual

Unity 180 Premium Whirlpool 180/80/62 cm

YS-B501 SPA Deluxe Overall Functional Capsule

Luxury Spas Inc. Instruction Manual E-35 Steam Shower. Instruction Manual 1

Water Distillation System Instruction Manual Nutriteam TC-501

Steam Room Installation Manual U880

Complete Shower Room Installation Guide and Operation Manual. Models 8727 / 8728

MAJESTIC Steam Cabin Installation Instructions

A301 SHOWER PANEL INSTALLATION GUIDE

PROGRAMMING INSTRUCTIONS

Your best choice! STEAM BATHROOM MODEL : WS-701. w w w.eaglebath.c o m. No advanced advice will be submit before we change our design and size.

Instructions. Portable Absorb Phlegm. Apparatus

Aquapeutics STEAM ROOM. Installation Manual WG-U6811. Make the most of your shower;make the best for your home!

Installation and Operation Manual MG-304. Please read this manual carefully before use.

24. Exhaust Fan. 2. ½ NPT Brass nut. 1. Brass Elbow. 4. Speaker. 6. Rain Shower head. 5. White LED Light. 16. Flex Drain Assembly

Model SPA-516 HOT TUB OPERATING INSTRUCTION

INSTALLATION AND USER MANUAL

SG User Manual

Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64

Murano Shower Cabin Installation Instruction

F A B G L A S S A N D M I R R O R

Leben im Bad Living bathrooms. St.Trop

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

Model SPA-8138 HOT TUB OPERATING INSTRUCTION

STEAM SHOWER ROOM. Index

INSTALLATION AND OWNER'S MANUAL

Contents. Product Description. Features. Quick Guide. Touch Panel Operation. Instruction. How to change the filter. Warning.

SHOWER SOFTENER-CEASA 1

900 Quadrant Steam Shower Cabin with 6 Body Jets

Sauna & Steam. STEAM GENERATOR (Domestic & Light Commercial) Assembly and operating manual PRODUCT IMAGE

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

Contents. Product Description. Features. Quick Guide. Touch Panel Operation. Instruction. How to change the filter. Warning.

A41. ALEKO Indoor Sauna.

Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

RESIN FREESTANDING TUB

ELECTRIC WATER HEATER HT382E55

808nm Diode Laser Hair Removal Machine. Diode Laser Hair Removal System 808S User Manual

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

Operating and assembly manual: Electric instantaneous flow heater Admiral

Clock Radio. User manual AJ260. Register your product and get support at

Model SPA-308 HOT TUB OPERATING INSTRUCTION

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Installation and Operating Instructions. Woda Heizung DWH 30A. Undercounter Drinking Water Heater

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

Oceanic Sauna Heater Manual

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

Medical Refrigerator

AIR MASSAGE KIT INSTALLATION INSTRUCTIONS

Installation and Homeowners Guide

INSTRUCTIONS FOR USE FLOW TYPE LUXURY COOLERS LINDR

Washing Machine OWNER S MANUAL. MODEL:MFW-V1100DDi

800x1000x2180mm. FIJI Multifunction Shower Cabin K-1607A Reversible FIJI LEFT. Drainer can not in the shadow area! FIJI RIGHT

Installation and Operating Manual

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

RUNLUCKY SHOWER SOFTENER SHOWER SOFTENER. User Manual. The appearance is just for reference. It is subject to the real product.

INSTALLATION AND OPERATION MANUAL FOR HUUM DROP ELECTRIC SAUNA HEATER

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

OPERATION & INSTRUCTION MANUAL. itouch GS08M(9kW & 18kW)

Installation Guide for Stern SPIKE 2 Speaker Light Kits

INSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP JDK-60, JDK-80, JDK-100, JDK-120

This manual provides many important safety points. Please read it carefully and follow the instruction rules.

Complete Shower Room Installation Guide and Operation Manual. Model 855

, '0''/).''$ /*'( 1'%* 00) ',))% *)) $ 3:36;$ !"## $%& '()*+,,,( '()*

ARLEC. User Instructions

INSTALLATION MANUAL FOR MODELS: SOVANNA, BREZZA, TERRACINA, VENADO

Transcription:

Installation Instructions Europa Shower Cabinet traditional contemporary bathrooms

Installation Instructions Europa Shower Cabinet Parts 1 M5x20 Screw x20 2 1 2 Transformer x1 3 Control Electronic Box x1 4 Top Lamp x1 5 Top Spray x1 6 ST3.5X16 x3 1 4 5 13 13 14 6 1 7 7 Top Cover x1 8 Left Panel x1 9 Mirror x1 10 Fixed Column x2 11 Left Side Shelf x1 12 M5x30 Screw x9 13 Pressed Strip of Back Panel Column x4 14 Back Panel x1 15 Back Panel Shelf x1 9 10 11 8 15 16 17 18 19 20 21 22 23 24 25 16 Jet x6 24 17 Shower Lift Rod x1 18 Side Panel x1 3 27 26 19 Speaker x1 20 Fan x1 12 21 Handheld Showerhead x1 22 Control Panel x1 28 23 Four-way Faucet x1 24 Shower Flexible Tube x1 25 Shower Joint x2 26 Foot Massage x1 27 Massage Flexible Tube x1 28 Tray x1 29 Pulley x8 30 ST3.5X25 Screw x8 31 ST4X25 Screw x8 33 30 34 31 29 36 35 32 37 38 32 37 31 36 39 35 30 34 33 32 Pressed Strip x4 33 Side Column x1 34 U Rubber x2 35 Fixed Glass x2 40 36 Waterproof Rubber x4 37 Movable Glass x2 38 Magnetic Fittings x2 39 Top & Bottom Rail x2 40 T Shape Handle x2 39 Warning: In order to make sure the safety, a disconnecting device must be installed in the fixed line while connecting conductors. 30 29 32 32 30 31 31

Electrical Parameter Voltage Rating Rated Frequency Steam Power Control Circuit Voltage Load Electrical Parameter AC 220V 50Hz 2.8Kw 12V The Load Parameter of 128C Type Controller: Voltage Rating AC 220V Rated Frequency 50Hz/60Hz Circuit Power P1 26.4W Controlled Power P2<4.4KW Controlled Current I2<20A The Load Parameter of Configurations for 128C Type Controller. Ceiling Lamp AC220V Side Lamp AC12V Fan DC12V Electrical Installation The power supply facilities of the house should be in accordance with the state standards, the voltage and frequency of the power supply should match the products demands. Make sure to install residual current circuit breaker, check and prove that the ground protection device is effective; The power line of the Complete Cabinet should be permanent wiring,when the power line passes through the wall, we should use protection bushing till the power supply connects with the plug socket; Connect the ground connection of the Complete Cabinet with that of the house, and prove it effective; Connect the connecting terminals of the electrical control box outgoing line to the control board, overhead light, speaker, background light and the exhaust fan respectively. Attached with the connection drawing of JG 128C controller Speaker Water level sensor Overheating protector Discharge Valve (DC12V) Water Inlet Valve Fan(DC12V) Temperature Sensor Radio Board Four-core signal wire Key Board Control Box (M) point of cold and hot water inside the bathroom should be set in the part of the steam cabinet easily being sheltered, connect with the joints of the hot and cold water through the flexible tube. The direction of the water tube is decided by the consumer himself, no flexible tubes are available with the machine. Installation Instructions Balance the bottom, regulate the foot screws and make it level; The installation of the glass door: Put the fixed glass on the upper and lower guide rail, fix the glass with the pressed strip and ST4X15 selftaping screws, let the ST3.5X25 self-taping screws pass through the reserved holes on the side column to fix the two side columns on the upper and lower guide rails as shown below. Movable Glass Pulley Fitting The installation of the movable door please refer to picture opposite, put the upper pulley on the top of the movable door, hang the movable on the slot of the upper guide rail aslant, and put the lower pulley into the slot of the guide rail to install the lower pulley, if the movable doesn t block and can be operated smoothly, it is ok; Live wire(l) Null line(n) Ground lead(g) Ground lead(g) Null line(n) Live wire(l) NGL Power Supply AC 220V 50Hz/60Hz Side Light(AC12V) Overhead Light 220V/50Hz Secondary 1 Time Secondary 2 Time Transformer Primary Water Supply Installation The water supply pressure of this facility is 0.2-0.4Mpa; The characteristics of the water supply on the wall: the water supply

Installation Instructions Europa Shower Cabinet Do as picture 7, and move the back panel onto the bottom and connect it with the tray with M5x30 screws. (Not fix the screws too firmly) As shown in picture 8 and 10, move the left and right side panels onto the tray, and install the side panel on the tray with M5X30 screws (Attention: Not fix the screws too firmly); and do as picture 9, let M5X20 screws pass through the reserved holes of the enforced board, the back and side panels and fix them, after flushing the left and right side panels with the tray, fix the back and side panels on the tray. Back Panel Enforceed Board Side Panel Enforced Board Screw Plain Gasket Nut Move the installed glass onto the tray (as picture 6), and insert the two columns of the glass door into the fixed column of the side panel; The installation of top cover refer to picture 12, move the top cover onto the top of the cabinet, and fix the top cover on the rail of the glass door with ST3.5X16 screws; fix the top cover on the back and side panels with M5X20 screws; Connect the top spray pipe with the top spray joint, and connect the cold and hot pipes with cold and hot water pipes according to left hot and right cold; Connect the wires of back lamp and control power well, and daub the glass glue on the connecting parts and check whether the grounding is alright or not, and enjoy the shower after ensure that everything Contol Panel Operation Instructions: When any function keys operate, the buzzer will ring. Power Switch Key Press this key, the controller will start, LCD background light will be lit, LCD will show the indoor temperature and the actual time. Fan Key Press the Fan key to turn on the fan, the LCD will show the turning fan icon; after pressing the key, the fan will be turned off, the fan icon shown on the LCD will disappear. Illumination Lamp Key The illumination lamp is formed with the overhead lamp and the side lamp. When pressing the power switch key, the overhead lamp will be lit, the side lamp will be shut off; press the illumination lamp function key, the overhead will be shut off, the side lamp will be turned on; press the key again, the overhead and side lamps will be turned on; press the key again, the overhead and the side lamps will be shut off synchronously. It circles as follows: Steam Sauna Function Key Press Steam key, LCD will show the flashing steam sign, and the water inlet valve will be opened, and the water will go inside the water tank automatically.

THE OVERHEAD LAMP IS LIT; THE SIDE LAMP WILL BE SHUT OFF. THE OVERHEAD LAMP AND THE SIDE LAMP WILL BE SHUT OFF SYNCHRONOUSLY Illumination Light FM Memory Volume - and Hour Reset Frequency Tune - Temperature Reset Steam Sauna THE OVERHEAD LAMP IS SHUT OFF, THE SIDE LAMP WILL BE LIT. THE OVERHEAD AND THE SIDE LAMPS WILL BE LIT SYNCHRONOUSLY. Fan FM Switch and Actual Time Function Volume + and Minute Reset Frequency Turning + Time Reset Power Switch Time Reset Key Press the Time Key, the LCD will show the rest time in the radio frequency, press this key each time, the time will rise 5 minutes; when the time rises to 60 minutes, press this key again, the time will circulate to return to 10 minutes; if press the key beyond 3 seconds, this time will rise at the speed of 5 minutes/ 1 snd; if this key doesn't work within 2 seconds, the time is the set time. Time Set Scope: 10-60 minutes. Drain off water automatically When press the power switch to turn off the controller, the water tank valve will be opened to drain off water 2 minutes automatically after 2 hours(the main power is not turned off). If pull off the main power plug, the water drainage valve will not be opened, the water tank drainage valve will be opened again to drain off water 2 minutes automatically only after the main power is turned on. FM Digital Tune System This system may receive FM broadcast programs, the receiving frequency scope is 87.5MHz 108.0MHz, there is a built-in power amplification system less than 20w. FM/T Key When press the key, the system will enter FM receiving state, the broadcasting radio frequency is the radio frequency turned off last time, after pressing the key again, the system will turn off the FM broadcast. If there is no operation of the power switch, FM broadcast may be turned on or turned off solely If the water position sensor estimates that the water position is natural, the system will close the water inlet valve, the steam function will be started, the controller will control the inner temperature of the steam cabinet automatically according to the inside default (the inner acquiescent temperature is 50, the acquiescent time is 10 minutes); If lacking of water, the water will supply automatically. The system will work as follows: If the inside temperature is one centigrade higher than the acquiescent temperature, the steam generator will stop heating; If the inside temperature is one centigrade lower than the acquiescent temperature, the steam generator will heat up again; When resetting the temperature and the time, the controller will control the inside temperature of the steam cabinet according to the set point. The system will work as follows: If the inside temperature is one centigrade higher than the set temperature, the steam generator will stop heating; If the inside temperature is one centigrade lower than the acquiescent temperature, the steam generator will heat up again. If press the Steam key again, the steam function will be stopped, the steam sign displayed in the LCD will disappear. Temperature Reset Press the Temperature, the LCD will show the present inside temperature of the steam cabinet in radio frequency, if press this key each time, the temperature will rise one centigrade; when the temperature rises to 60, press the key again, the temperature will circulate to return to 25; if press the key beyond 3 seconds, the temperature will rise at the speed of 1 /1snd; if the key doesn't make response within 2 seconds, the temperature is the set temperature. The Temperature Set Scope: 25 C-60 C Tune + Frequency Key When you press the key, it will increase the tune frequency of one step size (1 step size =50 KHz), if press this key beyond 2 minutes, the system will search for FM radio station upwards automatically, the digital lock will lock the searched FM radio automatically, LCD will display the radio frequency; when the upper limit frequency is 108,0MHz, press this key again, the frequency will jump to 87.5MHz. Tune Frequency Key When you press the key, it will reduce the tune frequency of one step size (1 step size =50 KHz), if you press this key beyond 2 minutes, the system will search for FM radio station downwards automatically, the digital lock will lock the searched FM radio station automatically, LCD will display the radio frequency; when the lower limit frequency is 87.5MHz, press this key again, the frequency will jump to 108.0MHz. Volume Plus Volume + Key The digital volume of the radio system can be adjusted through the volume Plus and minus keys, the adjusting degree is 40 degrees, each degree is 2dB, the volume adjustment is 0 80dB. During the process of adjustment, the LCD will twinkle and display the volume numerical value in the frequency display position, and the final adjusted numerical value is the set value, after 2 seconds, the LCD will display the radio frequency before adjustment again. When the key is pressed each time, the volume will increase 2dB upwards, if pressing the key beyond 2 seconds, the volume will increase at the speed of 10 db/second upwards. Volume Reduce Volume Key When the key is pressed each time, the volume will reduce 2dB downwards, if pressing the key beyond 2 seconds, the volume will reduce at the speed of 10 db/second downwards.

Installation Instructions Europa Shower Cabinet Broadcasting Station Memory Key MEM (8 Memory Positions available) Broadcasting Station Memory: When you select the broadcasting station frequency you want to store, 2 seconds after pressing the MEM key, the frequency displayed on the LCD will twinkle, press the key at that time, choose the position to be stored, and then press the MEM key for 2 seconds again, the broadcasting station frequency will be stored in the selected memory position. Load of Broadcasting Station: When press the MEM Key, you can get the stored corresponding broadcasting stations, meanwhile the LCD will display the relevant position number and the broadcasting station frequency. Actual Time Function Hour Reset: When you press the FM/T key for two seconds, the LCD will twinkle to display the actual time, at the moment, when you press the VOL-/H key, the hour can be reset, the adjustment range is 0 24, when you adjust to 24,continue to press this key again, you can adjust from 0 again; when you press FM/T for 2 seconds, or you don't press the VOL+/H key within 2 seconds, the final twinkling numerical value is the hour enactment value. Minute Reset: When you press FM/T key for 2 seconds, the LCD will twinkle to display the actual time, at the moment, when you press VOL+/H key, you can adjust the minute, the adjustment range is 0 60,when you adjust to 60 and continue to adjust the key, you can repeat to adjust from 0 again; When you press the FM/T key for 2 seconds or you don't press the VOL+/H key within 2 seconds, the final twinkling numerical value is the minute enactment value. Error Intellectual Self Check Alarm Automatically There are 4 built-in intellectual errors self check functions. The definition of the error is as follows: Temperature sensor error: when the temperature sensor has a break or a short circuit, the LCD will show E1 with the alarm noise of the buzzer, meanwhile all the keys of the controller don't work. This time you must cut off the power, the system will work again after the error is resolved. Water level check error: When you use the steam function, the water level check function doesn't work, if the water lever is below the check water level, no water goes into, the floater doesn't work, and the error happens with the water level check circuit, the LCD will show E2 with the alarm noise of the buzzer, the steam generator will stop heating. At this time, the system will work again after the error is resolved. Water level check overtime error: When the water level check error E2 gives an alarm over 2 minutes and the power wasn't cut off, and the error was not resolved, the LCD will show E3 with the alarm noise of the buzzer, at this time, the power supply must be cut off; the system will work again after the error is resolved. System temperature too high error: When the water level check function doesn't work, and there is no water in the steam generator, the steam generator continue to heat and make the inner temperature too high, at this time, if the temperature 108, the LCD will show E5 with the alarm noise of the buzzer, the steam generator will stop heating. At this time, the power supply must be cut off; the system will work again after the error is resolved. Error Solution Fault Phenomenon Reason Solution Problems Default reasons Solutions No Power No Steam Water Goes Out From Steam Sprayer No Water From Massage Jet Leakage From Hose The plug is not in the socket. The protection switch breaks off. The heater of the steam generator is damaged. No water in the steam generator. There is a jam in the hose connecting steam outlet, or the hose is broken Floater is damaged. Work time is not enough for steam. The inside temperature is higher than the temperature reset. Just insert the plug into the socket firmly. Just find and resolve the short circuit. Just replace it. Check the water inlet electromagnetic valve. Just clean the jam or replace the floater. Just check the wires of the floater or replace the floater. Just wait after the water is heated to spurt steam Just wait when the inside temperature is lower than the enactment temperature, the steam function will work. The floater is broken. The wires break off. the wires of the floater. The water inlet Check and connect the electromagnetic valve electron wires. has problems. Check and replace it. Just check the floater and There is a jam in the massage jet. The sealing gasket is broken. Connector is loose. Hose is broken. Clean them. Replace it Adhibit it again. Replace it. No Light The circuit breaks off. Just replace it The Steam Is Not Level Scratches On the Steam Cabinet The Fan Doesn't Work Dirt On the Chromium- Plating Parts The circuit breaks off. Balance the screws of the bottom To polish it with tooth paste and soft cloth after soaking the 2000 type thin sand paper with water. Check and replace the control connecting wires. Clean with the soft cloth, forbidden to clean with rough cloth or nitric thinner. Continue

Cleanness and Maintenance The daily cleanness of the steam cabinet may be done with common liquid scour and soft cloth, it is forbidden to use the scour with the acetone ammonia. It is forbidden to use the disinfector with the formic acid and formaldehyde during the sterilizing. In order to make its surface bright, it can be polished by polishing compound. Remove the blotch with tooth paste and soft cloth. Remove the calcium (scale) on the surface with lemon juice, heating vinegar and the soft cloth. To remove the light scratch and burn by the cigarette, you can polish them with 2000 type sand cloth soaked into water, and then deal them with the polishing compound. After 20 times hot circulation, when you clean the steam generator, first dilute 5-10 gram citric acid with 0.5-1.7 liters warm water, and pour them into the generator through steam outlet with rubber pipe, turn on the power and press the steam key after 8-12 hours, cut off the switch key after 5 minutes heating, the system will let off the dirt automatically. Special Reminds: The installation of the steam cabinet should be conducted according to the instructions by the qualified staff. The power parameter should be accordance with the state standards; you must check the grounding facilities and the current leakage switch are effective. In order to make sure the safety, a disconnecting device must be installed in the fixed line while connecting conductors. The power supply and the water supply valve of the bathroom should be cut off after every shower. It is forbidden to use the steam function for high pressure patients, heart disease patients, diabetics and the sots. If some relevant parameters changes, additional notice is not available. If the consumers disobey the above clauses to lead the bad results, our company won't take any responsibilities. TRAY SIZE 170mm 750mm BACK WATER & WIRE WATERWAY DRAWING Hand-held shower Connect with foot massage Cold water 900mm 750mm Hot water 200mm BACK WIRE & PIPEWORK DRAWING Connect with top shower Sprayer Steam medicine box Attachment Water and Circuit Installation WATER AND CIRCUIT INSTALLATION Steam Generator 750mm 250V/10A 3x2.5mm Connect with Water Source 2150mm 2230mm 1865mm 500mm 750mm 1000mm 170mm 50mm 500mm 1345mm 50mm

traditional contemporary bathrooms www.tc-bathrooms.com Traditional Contemporary Bathrooms, Unit 2, Jubilee Way, Grange Moor, Wakefield WF4 4TD. Tel: 01924 845 000 Fax: 01924 845 001 Helpline 01924 845000