MS3602CH 2 Channel Motion Sensor For Outdoor Use Wall & Ceiling Mounted Quick & Easy Installation 2 Channels Channel 2 Distance Wiring Diagram 220-240V ~ 50Hz 14A Max. (cosø=1) 3000W for incandescent load 2300W for halogen load 600W for fluorescent load 6 sec ~ 12 min 3 ~ 16 meters Detection angle 0~360º Temperature compensation adjustable ambient light level control -20ºC ~ +45ºC IP44 On a very cold or hot day, MS3602CH can automatically adjust the Detecting Sensitivity to reduce the change of the detecting distance that is caused by the ambient temperature change Wall & ceiling mounted
MS3601CH Motion Sensor For Outdoor Use Wall & Ceiling Mounted Quick & Easy Installation 1 Channel Channel 1 Distance Wiring Diagram 220-240V ~ 50Hz 14A Max. (cosø=1) 3000W for incandescent load 2300W for halogen load 600W for fluorescent load 6 sec ~ 12 min 3 ~ 16 meters Detection angle 0~360º Temperature compensation adjustable ambient light level control -20ºC ~ +45ºC IP44 On a very cold or hot day, MS3601CH can automatically adjust the Detecting Sensitivity to reduce the change of the detecting distance that is caused by the ambient temperature change Wall & ceiling mounted 1800 778 823 technologies@middys.com.au middystechnologies.com.au
MS460 Motion Sensor For Indoor Use Ceiling Mounted Quick & Easy Installation 1 Channel Channel 1 Disctance Detection angle 360º Operation Mode Dimension 220-240V ~ 50Hz 5A for incandescent light 2.5A for fluorescent light (electric & magnetic ballast) 1/10 HP for motor 6 sec ~ 12 min 6 ~ 8 meters 5 ~ 0ºC ~ +45ºC IP40 Auto 110mm x 32mm Ceiling mounted
PS465 Presence Sensor For Indoor Use Ceiling Mounted Remote Control For Lighting Automation and 1-10V Dimming Control 1 Channel Channel 1 230V ~ ±10% 50/60Hz Incandescent Lamp: Max. 2000W AC Halogen Lamp: Max. 1000W LV Halogen Lamp: Max. 1000VA / 600W (traditional) Max. 1000VA / 900W (electronic) Fluorescent Lamp: Max. 1000VA / 600W(uncompensated) Max. 900VA / 100μF 25 x (1 x 18W); 12 x (2 x 18W) 15 x (1 x 36W); 7 x (2 x 36W) 10 x (1 x 58W); 5 x (2 x 58W) LED Lamp : Max. 500VA / 400W Energy Saving Lamp: Max. 600VA / 400W (include CFL and PL lamp) Control output interface: 1-10V DC, Max. 100mA (e.g. 50pcs electronic ballasts at 2mA) 10 sec ~ 30 min Distance 2 ~ 6 meters 10 ~ 2000 0ºC ~ +45ºC Detection angle 0~360º Class II Detector: IP40; Power box: IP20 on time in standby mode 5min, 10min, 15min & Ceiling mounted Wiring Diagram 1800 778 823 technologies@middys.com.au middystechnologies.com.au
PS465A Presence Sensor For Indoor Use Ceiling Mounted 1 Channel Channel 1 Distance Detection angle on time in standby mode 220V-240V AC 50/60Hz Single loading control. (D1-D2):10A max. voltage free contact. (cosø=1) 10 sec ~ 30 min 2 ~ 6 meters 10 ~ 2000-10ºC ~ +45ºC 360º Circular IP40 5min, 10min, 15min & Ceiling mounted
PS4842CH 2 Channel Presence Sensor For Indoor / Outdoor Use Ceiling Mounted Quick & Easy Installation 2 Channel Channel 2 Wiring Diagram 230V ~ ±10% 50/60Hz I (CH1) for Lighting Incandescent Lamp : Max. 2000W AC Halogen Lamp : Max. 1000W LV Halogen Lamp : Max. 1000VA / 600W (traditional) Max. 1000VA / 900W (electronics) Fluorescent Lamp : Max. 1000VA / 600W (uncompensated) Max. 900VA / 100µF 25 x (1 x 18W); 15 x (1 x 36W); 10 x (1 x 58W) 12 x (2 x 18W); 7 x (2 x 36W); 5 x (2 x 58W) LED Lamp : Max. 500VA / 400W Energy Saving Lamp: Max. 600VA / 400W (include CFL and PL lamp) Control Output Interface: 1-10V DC, Max. 100mA (e.g. 50pcs electronic ballasts at 2mA) II(CH2) for HVAC (Reaction is regardless of value): Max. 5A (cosø=1) for 250VAC Max. 5A for 30VDC Max. 1A (cosø=0.4) for 250VAC 10 sec ~ 30 min Disctance 4 ~ 8 meters 10 ~ 2000 0ºC ~ +45ºC (indoor) -20ºC ~ +45ºC (outdoor) Detection angle 360º Class II IP40 (Flush mount with power box cap SP-96 and European standard junction box) IP54 (Surface mount with junction box) on time in standby mode 5min, 10min, 15min & Ceiling mounted 1800 778 823 technologies@middys.com.au middystechnologies.com.au
1800 778 823 technologies@middys.com.au middystechnologies.com.au