For Lacanche CLUNY IMPORTANT INFORMATION FOR CUSTOMERS TO READ Please read before delivery/installation of your cooker Thank you for purchasing a Lacanche Cooker. To ensure that delivery/installation of your cooker runs smoothly it is essential that you read the following carefully and adhere to all specifications. Please feel free to contact us regarding any aspect of the purchase of your Lacanche cooker. The sales office telephone number is 01202 733011. Gas Supply Please check that the gas supply required (Natural/LPG) is correctly stated on our Order Acknowledgement. A suitable diameter copper pipe is required to supply the appliance with a constant 20 millibars of natural or 37 millibars of propane gas. The last metre of the copper pipe should step to a 15mm diameter. The gas pipe should terminate a maximum of 500mm to the right (not directly behind) of the appliance. The pipework should be at a height of 500mm and terminate with a plug in female bayonet pointing downwards. Please see Fig 1 Access to the plug in bayonet must be maintained at all times. The flexible cooker pipe must be un-obstructed and be able to hang from the bayonet to the cooker in a U shape. Please see Fig 2 ALL GAS PIPEWORK AND VENTILATION MUST COMPLY WITH GAS SAFE REGULATIONS
Electrical Connections The al connection point must be within 1 metre of the appliance. The root of the wire connection must be such that the is not subjected to extremes of temperature or mechanical damage. There must be a double pole isolation switch, which must be easily accessible for the user and not placed behind the appliance. The correct rate of fuse must be fitted at the consumer unit. The al connections required are ticked below: Cluny Model Total Electrical Load kw 13 amp size 2.5mm LG1052GE 2.5 20 amp size 6mm LG1052E 5 LG1052GCT 2.65 32 amp size 6mm LG1052ECT 5.15 LCF1052GE 2.5 LCF1052E 5 LCF1052GCT 2.65 LCF1052ECT 5.15 45 amp size 10mm LVTR1052EE 15.6 LVTR1052ECT 15.75 LVI1052EE 16.9 LVI1052ECT 17.05 2 x twin 30 amp size 6mm per supply ALL ELECTRICAL CONNECTIONS TO THE COOKING APPLIANCE MUST BE MADE IN ACCORDANCE WITH THE IEE WIRING REGULATIONS
Building in Instructions 1. When the appliance is being built in to a run of units, a gap of 50mm must be allowed on both sides unless the sides of the unit adjacent to the cooker are covered with a noncombustible material. Secondly, the units must not be built proud of the oven doors, but must be flushed with the main body of the oven. 2. The stainless steel hob of the appliance must be at the same height as the adjoining worktops. These worktops can butt up to the hob. 3. If a plinth is required to make the cooker up to the work top height, the depth of the plinth is less that than of the depth of the cooker, see adjoining drawings. The plinth should be made out of hard wood or concrete. The depth of the plinth from back to front should be 590mm. 4. The minimum height above the hob of a cooker that an extractor can be placed is 800/850mm (depending on which model extractor). Wall units that are placed to the left and right of the cooker must allow an extra distance of a minimum of 100mm away from the hob on both sides. No combustible material, such as timber shelving should be placed directly above the cooker.
Important Delivery Details Please inspect your cooker at the time of delivery. If the appliance is received damaged please sign the delivery docket as damaged and report to Fourneaux De France Ltd within 24 hours of the day of delivery. Fourneaux De France Ltd will accept no claims for damage unless the above procedure is followed. Do not lift the cooker by the hand rail as this will result in damage to the control panel which will not be covered by the manufactures warranty Old appliances and packaging will not be removed. Deliveries are on an anytime during the day basis from 8.00am to 8.00pm. Door widths must be a minimum of 750mm. Please advise us if there are any obstructions or hindrances, e.g. steps to basements, narrow passages or if the delivery is not to a ground floor. Warranty Your Lacanche cooker has a 3 year electro mechanical parts and labour warranty. This warranty is subject to completion and return of the customer registration form to Fourneaux de France Ltd. We must point out at this stage that, should you experience any problems that are directly attributable to faulty connection or poor commissioning carried out by an engineer other than our own, they will not be covered by the warranty and a call out charge will be made to rectify the problem. Should you have any queries at all concerning this information or require any further assistance, please do not hesitate to contact us or your local stockist
Fig 1 Correct Position of Bayonet. Fig 2 Correct Position of Bayonet and Gas Hose.
900/916
All Electric Range 900/916 900/916