E2 Series Installation

Similar documents
FREWIN STEAM SHOWER ENCLOSURE

LEVENS STEAM SHOWER ENCLOSURE

ARLEY STEAM SHOWER ENCLOSURE

Electrical Installation Instructions

NEPTUNE Steam Room Installation Instructions

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

AQUAPEUTICS MONACO INSTALLATION MANUAL

Figure 1 - Steam Generator. Electrical Installation Instructions. 01/09 Pub. No. 200-A - 1 -

Installation Instructions PRO SERIES

INSTALLATION MANUAL FOR MODELS: SOVANNA, BREZZA, TERRACINA, VENADO

Steamist Installation Guidelines

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

INSTALLATION AND USER MANUAL

MAJESTIC Steam Cabin Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS Page 1

Installation Instructions Day Spa Generator

OWNER S MANUAL ONE-PERSON & TWO-PERSON SAUNAS WITH CERAMIC OR CARBON HEATERS

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

ULTRA SAUNA GAS INSTALL

SK SERIES INSTALLATION INSTRUCTIONS 1

INSTALL AN ELECTRIC SHOWER

S-Series 3 Person Infrared Sauna IG-870-SH/S870 User Manual

OWNER S MANUAL THREE-PERSON & FOUR-PERSON CORNER SAUNAS

ELLA OUTWARD SWING DOOR WALK IN BATHS OWNERS MANUAL

ULTRA-SAUNA HEATER. Proudly made in USA since Gas Heaters - 40,000-80,000 BTU. Installation Instructions & User Manual

signals a situation where minor injury or product damage may occur if you do not follow instructions.

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-870-SH/S870 User Manual

Installation and Operation Manual MG-304. Please read this manual carefully before use.

REFLECTION STEAM CABIN INSTALLATION INSTRUCTIONS

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-830-SH/S830 User Manual

INSTALLATION AND OPERATING INSTRUCTIONS

Infrared Room Installation & Operation Instructions

1-866-PENNERS

Installation Instructions

ELLA MASSAGE WALK IN BATHS OWNERS MANUAL

OWNER S MANUAL FOUR-PERSON & SIX-PERSON SAUNAS

INSTALLATION AND OPERATING INSTRUCTIONS

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Owner s Manual for the Passport Series Rooms PS 44 With SaunaLogic Control

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

BURWELL BIDET TOILET SEAT INSTALLATION

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-530 BH

ELLA SOAKING WALK IN BATHS OWNERS MANUAL. Representing these model numbers: L / R Elite Soaking L / R Royal Soaking

POWER PAK 480V Commercial Steam bath Generator

Whirlpool Bathtub Model Number: MT618

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

L A signature series TA T N E RE O, A L L A T S IN

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only.

SYSTEM BASIC WHIRLPOOLS

OVER 55 YEARS OF STEAM SHOWER INNOVATION

Dishwasher Installation Manual

900 Quadrant Steam Shower Cabin with 6 Body Jets

OWNER S MANUAL Serenity Half Sauna

Installation Manual for M-G014 & M-G015

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI10

Owner s Manual FS-10/FreshSpa

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI 40 CE

Luxury Spas Inc. Instruction Manual E-35 Steam Shower. Instruction Manual 1

Before you begin, carefully read the installation instructions below. Observe all local electrical safety and plumbing codes.

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Control Series Operation Instructions Page 1. "Digi VII"

Acrylic Claw Foot Tub

COPPER FREESTANDING TUB

Infrared sauna SUN S Pure Infra User Manual

PRO SERIES IMPORTANT SAFETY INFORMATION

ELLA HYDRO MASSAGE WALK IN BATHS OWNERS MANUAL

ELLA ACRYLIC WALK IN BATHTUBS OWNERS MANUAL

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

Mini Mist Installation Instructions. Health. Relaxation. Exhilaration

Signature Series Control

Steam Room Installation Manual U880

ThermaSol PowerPak Series Installation & Operating Instructions Commercial Steam Bath Generators (Three Phase)

INSTALLTION MANUAL FOR M-A6012

ELLA SOAKING WALK IN BATHS OWNERS MANUAL REPRESENTING THESE MODEL NUMBERS: L / R Elite Soaking L / R Royal Soaking

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

INSTALLATION AND OWNER'S MANUAL

Bravo II. High Performance Multi-Purpose Speaker

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

OWNER S MANUAL 1-2 PERSON SAUNA

Quick Start Guide. 4MP Vandal Dome Fixed Lens IP Camera O4D1

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Installation Instructions

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

For Tutorials and Troubleshooting visit

Oceanic Sauna Heater Manual

Hallmark Rooms HM 55C and HM 66C Owner s Manual with SaunaLogic Control and Bluetooth Sound System

Packing list. Packing 1. Packing 2. Packing 3. Spare parts list

INSTALLATION AND USER MANUAL

INS2000 INSTALLATION MANUAL. ATTENTION INSTALLERS: These instructions must be left with the customer WARRANTY REG NO:

Barrel Outdoor Sauna

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

Installation Instructions Fascia for Dual Roller FlexShade by Draper

Transcription:

E Series Installation Residential Modular Steam Shower Systems IMPORTANT: The following information should be used in conjunction with guidance from your electrician, plumber, architect and other contractors to determine a suitable and safe steam room environment. The following must be observed for safe and proper installation and operation.. Steam room must be completely enclosed with full walls ceiling, floor and door (note: a gap should be left under the door). It is recommended that the steam door is sealed on sides and top.. Make sure anti-slip surface stripping is applied for bathers safety. 4. No heating or air conditioning device should be installed inside the room. 5. Door should not contain a lock and should always open outward or sideways. 6. Before installation of generator, be sure the model is correct for incoming line voltage. 7. The below warnings should be posted outside of the steam room WARNING Children under the age of 6 should not use steam bath Check with a physician before use of the steam bath if pregnant, have a coronary condition, or are in poor health, are being treated for any medical condition, or are under medication. Exit steam room immediately if feeling faint, dizzy or uncomfortable. Do not use the steam bath if you have recently consumed alcohol. Condensation and moisture may cause the steam bath floor and other surfaces to become slippery and dangerous. Installation of anti-skid material is recommended. IMPORTANT - read the manual for further safety information. General Rule - Locate the steam generator as close to the steam room as possible. The generator cannot be located inside the steam room or in an outdoors location or in a location exposed to cold conditions. The location must be in a dry place and away from daily contact of adults and children. Do not install generator near flammable or corrosive materials or chemicals. The unit must be within 0 ft of the steam room. Install generator in upright position only. Install anti-water hammer device as necessary Provide unions as required to facilitate installation and disconnection of piping. WARNING: Steam line, safety valve, drain valve, plumbing and steam-heads become hot during and after operation. Provide appropriate protection, including insulating plumbing lines. Avoid plumbing runs and steam head locations that can come in contact with bathers and people in general.

E Shower Pre-installation Details Before you begin assembling your new E steam shower, site preparation will make the installation go smoothly. Your water connections should be approximately 6" from the back wall and 49" from the floor. It is advised to use flexible tubing (that meets your local code) that provides at least 8" of length that will allow you to connect the water lines while the unit is spaced from the wall for assembly purposes. Plumbing must be performed according to local codes and by a licensed professional. The power connection for your Scandia E feeds the entire electrical system. The power feeds should be located according to the below listed parameters. The electrical connection must be done according to local codes and by a licensed professional. In order to provide a direct drain to the plumbing system. Prepare the shower drain location according to the specifications below. The E drainage system includes a full hardware installation kit. Local codes may vary so it is important to anticipate these requirements in order to make drain modifications if necessary. Water Line Size / Inch Drain Size inch Power Feed KW Voltage Phase Amps Breaker AWG 40.5 0A

E Shower Accessories Installation Step : Place base near location - allow room away from the wall for completing assembly before moving into place. On the base, adjust unit legs with a wrench to desired height. This unit is designed to be located on uneven surfaces by adjusting the legs Step &: Place back wall panels into place. Fasten the panels at the base, lower center section should not be fastened until center panel is in place. 4 4 Step 4: Remove center panel plexi-glass back covers. Place center panel per illustration. Line up conduit holes and place black rubber conduit hole protectors in place. Steam Line 5 Step 5: Screw together all three above panels, also screwing to the shower base. 6 Step 6: Put shower roof in place. Insert roof screws into the back panel locations but do not tighten. Roof screws must remain loose till front glass and door panels are put into place. 6

E Shower Accessories Installation Step : Place base near location - allow room away from the wall for completing assembly before moving into place. On the base, adjust unit legs with a wrench to desired height. This unit is designed to be located on uneven surfaces by adjusting the legs Step &: Place back wall panels into place. Fasten the panels at the base, lower center section should not be fastened until center panel is in place. 4 4 Step 4: Remove center panel plexi-glass back covers. Place center panel per illustration. Line up conduit holes and place black rubber conduit hole protectors in place. Steam Line 5 Step 5: Screw together all three above panels, also screwing to the shower base. 6 Step 6: Put shower roof in place. Insert roof screws into the back panel locations but do not tighten. Roof screws must remain loose till front glass and door panels are put into place. 6

E Shower Accessories Installation Most components to your Scandia E steam shower come pre assembled, however there are a few components you must install on-site. Your shower head and water line connections must be installed. From the accessories box, connect the shower head with the water-line hose. Connect the other end of the water line hose to the shower head connection located on the right-hand seat panel. The E is comes with an extra large seat bench that provides ample seating for two adults. The seat is stylish and made of solid mahogany wood. The seat connection points are located on the seat platforms on each of the side panels. These bolts must be fastened tightly to secure the seat. The Scandia foot massager is engaged by water pressure. This unit is controlled by the control panel in the shower. Connect the water line feed of the foot massager to the water connection head located at the base of the right-hand seat panel. There are two mounting brackets for the foot massager that allows for easy detachment and replacement.

E Steam Shower Water-line Overview To Center Panel - Base Connection To Ceiling Shower To Removable Shower Head To Center Panel (white lines) To Foot Massage Capped Cold Water Intake Hot Water Intake To Steam Generator Intake (Scandia E-00 II, Water-line Overview)

E Steam Shower Water Line Map Referencing the waterline overview, each connection is pre-labeled. Connect all lines according to the corresponding labels. Below shows the direction/location of each water-line highlighted in the overview. Be sure to double check all connections to be sure they are tight before turning on water. Ceiling shower connection Center panel base connection Center panel (white line) connection Shower head connection Cold Water Intake Hot Water Intake Steam Line Foot massage connection Steam generator water intake

E Steam System Control Box Your Scandia E steam shower is computer controlled. This System Control Box provides all communication distribution from the digital interface located inside the steam room. All connections for your System Control Box are clearly labeled and have similar corresponding connection types and labeling. Three mounting screws are provided for secure mounting of the box. Once mounted. Connect all electrical components, all connections should be done before connecting main power feeds. System Control Box CD connection Microphone Steam Gen Connection T Telephone Power Connection Shower Controller Steam Generator Fan Light Stereo Speaker

E Steam System Control Box Your Scandia E steam generator is controlled from the digital interface within the shower cabin. Connect the power and communication feeds from the System Control box to the terminals on the steam generator. Connect the water feed from the back panel system and connect the steam line tubing to the steam head connection on the back panel. Note: in many areas, local code specifies the type of material used for steam-lines. Make sure your plumber uses accepted materials for the steam line feed. The system is equipped with an auto-drain, the drain feed must be plumbed to the steam room or drain infrastructure. The location must be so that the hot water from the drain system cannot burn the bathers. Power feed to control box Communication to control box Steam Generator Water intake from back panel feed Steam outlet to steam head System drain

E Digital Steam Control System Interface Control Box Your Scandia E system is controlled from within the shower with the digital control panel or remotely with the remote control device. The below illustrations indicate all functions of the digital controls. LCD display Temp/volume control Function selector Shower fan Side massage spray Storing channel selections Timer alarm button Illustration # Temp/volume control Light Steam activator Side massage spray Radio station selector Stereo controls Power button Microphone location Your E steam shower comes with an integrated telephone that allows you to make and receive phone calls from within the shower in a hands free fashion. When the telephone function is selected, the keypads with corresponding numbers are used to dial the phone. Illustration # shows the location of the telephone number keys. 0 4 5 6 7 8 9 Illustration #