Download the BEA DECODER app for a quick overview of settings

Similar documents
Download the BEA DECODER app for a quick overview of settings

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

LZR -WIDESCAN. Motion, Presence, and Safety Sensor for Industrial Doors (US version) DESCRIPTION ENGLISH

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

DDS-A / DDS-B HYBRID SENSOR

LZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

BODYGUARD-T USER S GUIDE

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

D-TECT 3 IP. GJD260 IP Motion Detector

FIRERAY 5000 range USER GUIDE

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

TruVision Bullet IR Camera Pocket Guide

TruVision Bullet IR Camera Pocket Guide

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

SCHMIDT LED Measured Value Display MD Instructions for Use

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

English. Italiano. Português. Françias. Español

Radio fire warning panel SRC 3000

Original operating instructions Safety switch with guard locking AC901S AC902S

DESIGN EASY ADJUSTMENT

SensaGuard TM Integrated Latch Installation Instructions

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Sensing light curtain as per DIN 18650/EN 16005

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

Memcom Emergency Telephone

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

AHD SPEED DOME CAMERA

Motorised Infrared Optical Beam Smoke Detector. User Guide

THX-DL Data Logger USER & INSTALLATION MANUAL V

POL-200-TS User Manual

VPS3 Installation Manual

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

MWS3 Ceiling Mount Microwave Occupancy Detector

Installation Instructions

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

EW 40 Wireless Fan Control

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

A-MIP 210 Installation and user guide

Acusensor 3. Instruction Manual

/ / 2018

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

Sensing light curtain as per DIN 18650/EN 16005

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Fume Hood Operating Display Panel

Wireless High Bay Sensor (WHS100) Installation Instructions

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Instructions for the fan motor control system with integrated wiring terminals SILVER C

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

English. FCC declaration. Electro Magnetic Compatibility (EMC) Warning. This device complies with part 15 of the FCC rules.

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

IR Speed Dome. Quick Guide UD.6L0201B1357A01

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

D-TECT 2 IP. GJD230 IP Motion Detector

BSR Addressable Fire Detection control panel. Installation operation manual

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

IndigoVision Alarm Panel. User Guide

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

PolyGard 2-channel Gas Controller MGC-03

Detector switch - Dual Tech SCS

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

1. Quick start-up guide

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Panel XTO210/610/710 GPRS

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

Ceiling Microwave presence/absence detector 12-24V AC/DC

Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

UV - Monitor UVT 16. Use. Description

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Transcription:

Download the BEA DECODER app for a quick overview of settings IXIO-DT1 V Activation & safety sensor with camera for automatic sliding doors ENGLISH DESCRIPTION 1 2 3 4 5 6 7 8 9 10 1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses 6. camera 7. cover 8. main connector 9. main adjustment knob 10. AIR-curtain angle adjustment knob ACCESSORIES 10IMB: Bracket accessory 10.1279: Replacement Kit Page 1 of 9 75.5816.08 IXIO-DT1 V UL 20170929

READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP LED-SIGNAL (green) Motion detection (red) Presence detection LED flashes x LED flashes x times LED flashes red-green LED flashes quickly LED is off INSTALLATION The sensor should be mounted securely to avoid extreme vibrations. Do not cover the sensor. Avoid moving objects and light sources in the detection field. Avoid highly reflective objects in the infrared field. MAINTENANCE It is recommended to clean the optical parts at least once a year or more if required due to environmental conditions. Do not use aggressive products to clean the optical parts. SAFETY The door control unit and the header cover profile must be correctly grounded. Only trained and qualified personnel are recommended for installation and set-up of the sensor. Following installation, always test for proper operation (according to ANSI 156.10) before leaving the premises. The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel. Page 2 of 9 75.5816.08 IXIO-DT1 V UL 20170929

READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP HOW TO USE THE LCD DISPLAY DURING NORMAL FUNCTIONING Activation impulse Safety Negative display = active output To adjust contrast, push and turn the grey button simultaneously. During normal function only. FACTORY VALUE VS. SAVED VALUE displayed value = factory value displayed value = saved value NAVIGATING IN MENUS Push to enter the LCD menu Password X X X X Enter password if necessary Not during the first minute after power-on of the sensor. Select your language before entering the first LCD menu. During the first 30 seconds after power-on of the sensor or later in the diagnostics menu. Scroll menu items Select Back to return to previous menu or display. Select More to go to next level: - basic settings (MENU 1) - advanced settings (MENU 2) - diagnostics (MENU 3) CHANGING A VALUE Scroll menu up/down Push to select parameter current value is displayed Scroll values up/down 6 6 Push more values are displayed to save new value new value is displayed CHANGING A ZIP CODE See application note on ZIP CODE (76.0024) ID # E24 1 56-KG4 E24 1 56-KG4 E24 1 56-KG4 H24 1 56-KG4 H24 1 56-KG4 H24 1 56-KG4 01 0 800/02D V Validate the last digit in order to activate the new : v = valid (values will be changed accordingly) x = invalid (no values will be changed) v/x = valid, but from a different product *only available values will be changed* VALUE CHECK WITH REMOTE CONTROL Pressing a parameter symbol on your remote control displays the saved value directly on the LCD screen. Do not unlock first. Page 3 of 9 75.5816.08 IXIO-DT1 V UL 20170929

1 MOUNTING & WIRING Use the provided mounting template and mount the sensor, ensuring that the bottom of the sensor is within 2 inches of the bottom of the door header. Route the harness using the harness clip as shown in the exploded view of the mounting illustration. 12-24 V AC, 50/60 Hz 12-30 V DC Max 2.5 W * RED BLACK BROWN BLUE POWER SUPPLY SAFETY INPUT max. 2 in * SENSOR WHITE YELLOW GREEN COM NC NO OPENING INPUT PURPLE PURPLE TEST OUTPUT** * Output status when sensor is operational. Mounting is compatible with the WIZARD. ** The sensor LED will briefly flash RED during monitoring communinication with door control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor and monitoring wires must be properly connected to the door control. Sensor connectivity (power and relays) must utilize only the supplied harness. Sensor and camera power must be supplied from a Class 2 supply source limited to 15 W. Sensor is intended to be monitored for proper operation by the door operator or system. Harness shall be routed separated from any Mains or non-class 2 voltage cable for correct operation or shall be rated for the Mains voltage, and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the harness. CAMERA Voltage Regulator 2 ANGLE RADAR OPENING IMPULSE FIELD The size of the detection field varies according to the mounting height of the sensor. The following graphics are representations - not default settings. field size: 9 immunity: 2 7.2 ft 7.2 ft field size: 9 immunity: 2 from 15 to 45, default 30 from -15 to 15, default 0 WIDTH field size: 9 immunity: 2 7.2 ft 7.2 ft field size: 9 immunity: 2 13 x 6 6" (wide) 6 6" x 8 (narrow) 1 1 grid is approximately 3.28 ft 3.28 ft. Page 4 of 9 75.5816.08 IXIO-DT1 V UL 20170929

3 INFRARED SAFETY FIELD ANGLE CLOSER DOOR OR AWAY max. 3 in** Activate the visible* spots to verify the position of the AIRcurtain. If necessary, adjust the AIRcurtain angle (from -7 to 4, default 0 ). * Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains. ** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 8 in. WIDTH Part of the detection field can be masked to reduce its width. The arrow position determines the width of the detection field. Additional adjustments are possible by LCD or remote control (see OVERVIEW OF SETTINGS). Always verify the actual detection field width by walk-testing according to ANSI 156.10 guidance. Mounting height 6 6" 7 3 16" 8 3 16" 9 13 16" 11 6" Detection width 6 6" 7 3 16" 8 3 16" 9 13 16" 11 6" The size of the detection field varies according to the mounting height and the settings of the sensor. The full door width must be covered. 4 SET-UP STEP OUT OF THE INFRARED FIELD! SET-UP 1 (QUICK) reference picture either hold the knob for 2 seconds, or use the remote control buttons as specified 2 s OR SET-UP 2 (ASSISTED) test of full door cycle reference picture either hold the knob for 4 seconds, or use the remote control buttons as specified 4 s OR TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES! Page 5 of 9 75.5816.08 IXIO-DT1 V UL 20170929

OVERVIEW OF SETTINGS 0 1 2 3 4 5 6 7 8 9 Back More RAD: FIELDSIZE small large BASIC AIR: WIDTH AIR: OUTPUT Energ/NC Energ/NC Energ/NC Energ/NC Always additionally adjust the arrow position on the sensor with a screwdriver. DeEner: De-Energized relay Energ: Energized relay NO: normally open NC: normally closed TEST off on The sensor LED will briefly flash RED during monitoring communication with door control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor and monitoring wires must be properly connected to the door control. More Back Back More RAD: FIELDSIZE small large RAD: IMMUNITY low high RAD: DIRECTION off bi uni uni MTF MTF: motion tracking feature RAD: HOLDTIME 0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s ADVANCED RAD: REENTRY RAD: OUTPUT AIR: IMMUNITY small Energ/NC Energ/NC Energ/NC Energ/NC normal enhanced mode B large DeEner: De-Energized relay Energ: Energized relay NO: normally open NC: normally closed AIR: WIDTH Always additionally adjust the arrow position on the sensor with a screwdriver. AIR: NUMBER 1 2 AIR: PRESENCE TIME 30 s 1 min 2 min 5 min 10 min 20 min 60 min infinte min. value for DIN18650: 1 min min. value for EN16005: 30 s AIR: FREQ AIR: OUTPUT A B Energ/NC Energ/NC Energ/NC Energ/NC DeEner: De-Energized relay Energ: Energized relay NO: normally open NC: normally closed TEST off on The sensor LED will briefly flash RED during monitoring communication with door control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor and monitoring wires must be properly connected to the door control. REDIRECTION FACTORY RESET motion motion or presence full reset partial reset opening output is active in case of: 0 motion detection 1 motion or presence detection 2 motion and presence detection partial: outputs are not reset DIAGNOSTICS More Back factory value AIR: C1 ENERG signal amplitude received on curtain 1 ZIP CODE all parameter settings in zipped format AIR: C2 ENERG signal amplitude received on curtain 2 (see application note on ZIP CODE 76.0024) POWERSUPPLY supply voltage at power connector ID # unique ID-number OPERATINGTIME power duration since first startup CONFIG P/N RESET LOG delete all saved errors SOFT P/N PASSWORD LCD and remote control password ERROR LOG last 10 errors day indication (0000= no password) AIR: SPOTVIEW view of spot(s) that trigger detection ADMIN enter code to access admin mode Page 6 of 9 75.5816.08 IXIO-DT1 V UL 20170929

TROUBLESHOOTING E1 E2 1 2 1x. 2x. The sensor signals an internal fault. The power supply voltage is too low/high. Replace sensor. Check power supply voltage in diagnotistics menu (menu 3) of the LCD. Check wiring. E4 4 4x. The sensor does not receive enough AIR-energy. Decrease the angle of the AIR-curtains. Increase the AIR-immunity filter. Deactivate 1 curtain. E5 5 5x. The sensor receives too much AIR-energy. The sensor is distrubed by external elements. Slightly increase the angle of the AIR-curtains. Decrease the AIR-immunity filter. Eliminate the cause of disturbance (lamps, rain cover, door controller housing properly grounded). E8 8 8x. ORANGE LED is on. IR power emitter is faulty. The sensor encounters a memory problem. Replace sensor. Cut and restore power supply. If ORANGE LED illuminates again, replace the sensor. RED LED flashes quickly after an assissted set-up The sensor sees the door during assissted set-up. Move the AIR-curtains away from the door. Install the sensor as close to the door as possible. If needed, use a bracket assembly. Ensure that the bottom of the sensor is mounted within 2 of the bottom of the door header. Launch a new assisted set-up. RED LED illuminates sporadically. The sensor vibrates. Check if the sensor is fastened firmly. Check position of cable and cover. The sensor sees the door. Adjust the IR angle and launch an assisted set-up. The sensor is disturbed by external conditions. Increase the AIR-immunity filter. GREEN LED illuminates sporadically. The sensor is disturbed by rain and/or leaves. Increase radar-immunity filter. Ghosting created by door movement. Change radar filed angle. The sensor vibrates. Check if the sensor and door cover is fastened firmly. Check position of cable and cover. The sensor sees the door or other moving objects. Remove the objects if possible. Change radar field size or angle. The LED and the LCD displays are off. No power to sensor. Check wiring. Check for correct power supply. The reaction of the door does not correspond with the LED signal. Incorrect output configuration / wiring. Check output configuration setting. Check wiring. troubleshooting continues on the next page Page 7 of 9 75.5816.08 IXIO-DT1 V UL 20170929

TROUBLESHOOTING (cont.) The LCD or remote control does not react. Visible External Monitoring / Test Indication LED (red) does not flash. The sensor is protected by a password. Monitoring installation/setup error. Sensor and/or wiring malfunction. Enter the correct password. If you forgot the code, cut and restore the power supply to access the sensor without entering a password during 1 minute. Verify door control is capable of monitoring and the sensor monitoring wires are properly connected to the door control. Verify monitoring (TEST) is on in the sensor settings. Verify that there are no breaks anywhere in the wire harness. Replace the sensor. IXIO sensors are intended to be used with pedestrian sliding door systems. This device can be expected to comply with Part 15 of the FCC Rules, provided it is assembled in exact accordance with the instructions provided with this kit. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. TECHNICAL SPECIFICATIONS (SENSOR) Supply voltage: 12 24 VAC ±10% 12 30 VDC ±10% to be operated from SELV-compatible power supplies only Power consumption: < 2.5 W Mounting height: 6 6 11 6 local regulations may impact acceptable mounting height Temperature range: Sensor: -13 131 F * 0 95% relative humidity, non-condensing LCD screen is operational from 14 131 F. The sensor may still be programmed in colder temperatures, but with the remote control. Degree of protection: IP54 Noise: < 70 db Applicable directives: Detection mode: Technology: Output: R&TTE 1999/5/EC MD 2006/42/EC LVD 2006/95/EC MOTION minimum detection speed: 2 in/s ROHS 2 2011/65/EU Microwave doppler radar Transmitter frequency: 24.150 GHz Transmitter radiated power: < 20 dbm EIRP Transmitter power density: < 5 mw/cm 2 Electro-mechanical-relay (potential and polarity free) Max. contact current: 1 A Max. contact voltage: 30 VDC Adjustable Holdtime: 0.5 9 s PRESENSE typical response time: < 200 ms (max: 500 ms) Active infrared with background analysis Spot: 2" x 2" (typ) Number of spots: max. 24 per curtain Number of curtains: 2 Solid-state-relay (potential and polarity free) Max. contact current: 400 ma Max. contact voltage: 42 VAC / VDC Holdtime: 0.3 1 s Specifications are subject to change without prior notice. All values measured in specific conditions. Test/Monitoring input: Sensitivity: Low: < 1 V High: 10 V (max. 30 V) Response time on test request: typical < 5 ms Norm conformity: EN 12978 EN ISO 13849-1:2008 PL «c» CAT. 2 (under the condition that the door control system monitors the sensor at least once per door cycle) IEC 61496-1:2012 ESPE Type 2 EN 16005:2012 Chapter 4.6.8 DIN 18650-1:2010 Chapter 5.7.4 BS 7036-1:1996 Chapter 8.1 see following page for camera specifications Page 8 of 9 75.5816.08 IXIO-DT1 V UL 20170929

TECHNICAL SPECIFICATIONS (CAMERA) BEA Original instructions 75.5816.08 IXIO-DT1 V UL 20170929 PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOR PRINTING Voltage regulator (built into wire harness): 6.6 36 VDC (±10%) 6 28 VAC (±10%) Operating temperature: -30 60 C (max. RH: 95%) Video output: Image Sensor: Horizontal resolution: NTSC output: Sync system: 1.0 (Vp-p) / 75Ω CMOS 480 TVL 720 (H) 480 (V) Inter-Sync Frame rate: Minimum illumination: AE control: Gain control: Electronic shutter: S/N ratio: BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA does not guarantee any use of the sensor outside of its intended purpose. BEA strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and factorytrained for the type of door/gate system. Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor system installation is compliant with local, national, and international regulations, codes, and standards. Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL 325). Verify that all appropriate industry signage and warning labels are in place. BEA hereby declares that the IXIO-DT1 is in conformity with the basic requirements and the other relevant provisions of the directives 1999/5/EC, 2006/95/EC and 2006/42/EC. Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen EC-type examination certificate number: 44 205 12 405836-001 Angleur, October 2014 Pierre Gardier, authorized representative and responsible for technical documentation The complete declaration of conformity is available on our website: www.bea-pedestrian.be AWB: 30 fps 0.01 LUX auto auto 1 s ~ 1/10,000s 50 db Auto Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE) Tech Support: 1-800-407-4545 Customer Service: 1-800-523-2462 General Tech Questions: Tech_Services@beainc.com Tech Docs: www.beainc.com Page 9 of 9 75.5816.08 IXIO-DT1 V UL 20170929