NGC-20-C-E and NGC-20-CL-E

Similar documents
NGC-20-C-E and NGC-20-CL-E

NGC-20-C-E and NGC-20-CL-E

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

HTC-915-CONT. Heat-Trace Control system

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

910 Series Single-point heat-tracing control system

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

Dual-point heat-tracing control system

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

C910 Series. Single-point heat-tracing control system

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

RAYCHEM NGC-30 COMPONENTS

NGC-40 Advanced Heat-Tracing Control System

ACCS-30. Multipoint commercial heat-tracing control system

DigiTrace NGC-family

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

NGC-20 LOCAL CONTROL CENTRAL MONITORING

DESCRIPTION. 42 mm. 125 mm

TraceNet ECM Series Control System

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Analog Annunciator Unit SACO 16 A3. Product Guide

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

THERMAL MANAGEMENT SOLUTIONS

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Carbon Monoxide Transmitter

THERMAL MANAGEMENT SOLUTIONS

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET Installation and Operating Instructions. Level switch for one sensor

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Model 144H. Product Data Sheet , Rev DB February Content

DigiTrace C910 Series Heat Trace Controller Installation, Operation, and Maintenance Manual

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

1.7. Insulation fault evaluators EDS460/490 EDS461/491

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Rosemount 3490 Series

DigiTrace T2000 Heat Trace Controller

NGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions

DESIGN GUIDELINES. THERMAL building SOLUTIONS

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

RE-PR3-E-27 3-Phase Panel Mount 27kW

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Integrated Solutions Low Voltage Systems

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Insulation fault evaluator EDS460-DG

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

Operating Manual MS220DA

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Model 144H. Product Data Sheet , Rev DB February Content

DB4 Range - SPEAKERS - Up to 25 Watts

Flameproof Manual Call Points Series MCP

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

DB5 Intrinsically Safe Sounder Type DB-5

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Danfoss gas detection unit Type GD Heavy Duty

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Series Temperature Controller Instruction Sheet

LC2200 Level Controller Installation and Maintenance Instructions

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

P R O D U C T D ATA S H E E T

SET-2000 Hi Level/Oil

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Labkotec Ice Detector

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Temperature Measurement Transmitters for field mounting

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Rules for Intruder Alarm Systems

Fisher LCP100 Local Control Panel

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Explosion Proof Manual Call Points Series MCP

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

Dräger Polytron 8000 Stationary gas detector (EC)

DICTATOR Hold-Open Systems for Hazardous Areas

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

ACS-30-EU-EMDR- 10-MOD

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Transcription:

Self-regulating Field-mountedheating cable Electronic heat-tracing control unit Product overview The DigiTrace NGC-20 is an electronic heat-tracing control unit featuring the benefits of local control and the capability for central monitoring. DigiTrace NGC-20 control unit can be used for single phase circuits up to and is approved for use in hazardous areas. The DigiTrace NGC-20 can provide tight temperature control and is available with an IEC 61508-SIL 2 classified safety temperature limiter on board (NGC-20-CL-E). It measures the temperature with up to two TD(s) connected to the unit. The Safety temperature limiter has a dedicated temperature input. Control, monitoring and alarm capabilities The DigiTrace NGC-20 offers several different control algorithms including PASC for an optimised electrical heat-tracing control. The DigiTrace NGC-20 offers alarms for high and low temperature, high and low current, ground-fault current and voltage. The trip and warning level of the groundfault current is user configurable and can be used as a warning and to isolate circuits. The DigiTrace NGC-20 control unit provides a dry contact relay for alarm annunciation. Automated heat-tracing system check To ensure system integrity the DigiTrace NGC-20 control unit can be configured to periodically check dormant heating cables for faults. As a consequence maintenance is systematically informed about the status of the heat-tracing system and unexpected and usually expensive downtime of important pipelines can be reduced. Communications and networking is equipped with a S-485 interface. Through this interface up to 247 DigiTrace NGC-20 units can be networked to a single DigiTrace NGC UIT or to one serial port of standard PC running Tyco Thermal Controls DigiTrace Supervisor software. can as well be monitored and/or configured via the DigiTrace NGC-CMA wireless handheld device. This device is available for hazardous and nonhazardous areas. Installation can be installed in the field near the heating application. The DigiTrace NGC-20 enclosures are manufactured from high impact-resistant, UV stabilized glass-filled polyester suitable for installation indoors or outdoors. One heating cable can be directly connected to the unit. The units can be mounted on the heated surface via an appropriate support bracket. Configuration and commissioning can be commissioned locally by means of a handheld programming device (DigiTrace NGC-CMA) or from a central location using the DigiTrace NGC-UIT or DigiTrace Supervisor Software. After programming, all settings are permanently stored in the non-volatile memory of the DigiTrace NGC-20 control unit, avoiding loss of data in the event of power failure or after a long term power shutdown. The DigiTrace NGC-20 control unit allows the heating and power cable to be connected directly to the unit. Heating Cables Components conrtrol and monitorning Accessories EN-NGC-20-C-E/CL-E-DS-DOC2210-1-08-2012 1-5

Dimensions (in mm) 220 120 Baseefa08ATEX0184X IECEx BAS 08.0047X Lot/Los/Lot N : II 2 GD GB Ex e mb ib IIC T* See Schedule Db Ex td A21 IP66 T95 C Serial number inside Seriennummer innen N de série à l interieur Heat-Tracing Temperature Control Unit with safety limiter Temperaturregler mit Sicherheitstemperaturbegrenzer Contrôleur/Limiteur de Température pour Traçage Electrique PN-1244-007036 1180 Leuven, Belgium Ex i Connections / Anschlüsse / accordements Safety Temperature Limiter according to: Baseefa08S0134 SIL2 Sicherheitstemperaturbegrenzer nach: IEC 61508-1:1998 & Limiteur de Sécurité selon: IEC 61508-2:2000 Operating voltage: Betriebsspannung: 100-254 VAC Tension nominale: Switch current de-rating table / Tabelle temparaturabhängiger Schaltstrom / Tableau de dégrèvement courant de coupure Temperature Class T5 Ambient temp. range Maximum switch current 40 C +50 C 40 C +54 C 20 A 40 C +56 C 16 A Temperature Class T4 Ambient temp. range Maximum switch current 40 C +56 C Texte Français dans le manuel technique Deutsche Texte siehe Betriebsanleitung ModBus: Ex e Connections / Anschlüsse / accordements 120 Sample shown is DigiTrace NGC-20-CL-E Gland included in scoop of delivery - 1 x M25 x 1,5 General Application type Approvals DigiTrace NGC-20-C(L)-E units are approved for use in Hazardous area Zone 1 or Zone 2 (Gas) or Zone 21 or Zone 22 (Dust) and non hazardous areas Baseefa08ATEX0184X II 2 GD Gb Ex e mb ib IIC T* Db Ex td A21 IP66 T95 C IECEx BAS 08.0047X Gb Ex e mb ib IIC T* Db Ex td A21 IP66 T95 C T*: The switching capacity depends on the hazardous area temperature classification (T-Class) and the maximum expected use temperature. atings as shown in table below Temperature Class T5 Maximum Ambient Temperature Maximum Switching Current Temperature Class T4 Maximum Ambient Temperature Maximum Switching Current +50 C +54 C 20 A Up to 56 C +56 C 16 A All values as per hazardous area certification. Current ratings are given for a supply voltage of 254 V +/-10%, 50/60 Hz and resistive loads only. Functional safety approval 1 Conditions of Safe Use Environmental Temperature range control unit Temperature range limiter Ambient operating temperature Storage temperature Baseefa08S0134 SIL2 IEC 61508-1:1998 & IEC 61508-2:2000 efer to Hazardous Area Certificate or installation instructions From 80 C to +700 C in steps of 1K From 60 C to +599 C in steps of 1K (NGC-20-CL-E only) From 40 C to +56 C From 55 C to +80 C 2-5 EN-NGC-20-C-E/CL-E-DS-DOC2210-1-08-2012

Enclosure Protection Material Entries Mounting & installation Installation position DigiTrace NGC-20-C(L)-E units can be installed directly on the pipe via an appropriate support bracket as long as the maximum permitted ambient temperature is not exceeded. Alternatively, units can be mounted on any stable structure via the moulded holes in the enclosure. IP 66 per IEC-60529 Glass fibre reinforced enclosure with internal earth plate on the bottom 1 x M25 gland Ø 8 17 mm: power IN/heating cable out 3 x M25 1 x M25 stopping plug: daisy chaining of power 1 x M25 rain plug: daisy chaining of power Digital communication IN/OUT and alarm 3 x M20 (all with stopping plugs) 2 X M16 Temperature sensor(s) 1 with stopping plug one with rain plug Installation on an appropriate support bracket directly on the heated surface up to temperatures of 230 C. When the temperature of the heated surface is above 230 C, install the control unit to a stable structure nearby the application. Any position allowed, typical use with glands facing down 1 EC-61508 Safety related information is published in the NGC-20 installation instructions INSTALL-130. A copy of the INSTALL-130 can be downloaded from the literature section on http:// or can be obtained via your local Tyco Thermal Controls representative. Electrical data Power supply & own power 100 Vac to 254 Vac +/-10 % 50/60 Hz 20 VA max. consumption Connection terminals Spring-type L, N and terminals 9 pc (cables with diameter ranging from 0.2 to 6 mm 2 ) Alarm output terminals 3 pc (cables with diameter ranging from 0.2 to 2.5 mm 2 ) Pt 100 (TD) terminals 12 pc (cables with diameter ranging from 0.2 to 1.5 mm 2 ) S-485 communication 7 pc (0.2 to 1.5 mm 2 ) Internal Earth stud for TD shield 1 pc (Cable diameter max 6 mm 2 ) Contact lifetime main switch 500k operations at /250 Vac (resistive load) Alarm output relay Contact rated 250 Vac/3 A elay output is software programmable to open, close or to toggle in case of alarm Electromagnetic compatibility EN 61000-6-2:2005 (Gen. Immunity standard for industrial environments) EN 61000-6-3:2007 (Gen. Emission standard for residential, commercial and light industrial) EN 61000-3-2-2006 (Limits for harmonic current emissions) EN 61000-3-3:1995+A1:2001+A2:2005 (limitation of voltage fluctuations and flicker) Electrical safety EN 61010-1, Category III, Pollution degree 2 Vibration & Shock Shock to EN 60068-2-27: 1/2 sine wave of 11 ms duration, 15 g Vibration to EN 60068-2-6/sine wave 10 to 150 Hz (p-p), 2 g Temperature sensors Compatible types 100 Ω platinum, 3-wire, α = 0.00385 Ω/ C. Can be extended with a three core shielded or braided cable of maximum 20 Ω lead resistance per conductor. Quantity Two TD inputs for the control unit plus one independent temperature input for the safety limiter. All temperature sensors are permanently monitored for sensor short, sensor break. Communications Physical network S-485 and Bluetooth Class 1 Protocol/topology Modbus TU or ASCII. Multi drop/daisy chain Cable and maximum length Shielded twisted pair cable, 0.5 mm 2 (AWG 24) or larger maximum cable length between should be no more than 1200 m Maximum quantity of control units Max. of 247 units per DigiTrace NGC-UIT or per serial communication port in one network (Modbus) Network address Software programmable via DigiTrace NGC-CMA-NH, DigiTrace NGC-CMA-EX or DigiTrace Supervisor EN-NGC-20-C-E/CL-E-DS-DOC2210-1-08-2012 3-5

Programming and setting Method Units of measure Memory LED indicators NGC-20-C-E NGC-20-CL-E Through handheld programming device DigiTrace NGC-CMA-NH, NGC-CMA-EX (hazardous area) and a wireless Bluetooth connection or via S485 interface and DigiTrace Supervisor software or DigiTrace User Interface Terminal (NGC-UIT2-OD) and DigiTrace software. C or F, software selectable Non-volatile, no loss of parameters after the event of power outage or long term shut down, data holding time ~10 years. Status LEDS are available for: Heater, Alarm, S-485 communication, Bluetooth communication Heater, Alarm, Limiter Tripped, S-485 communication and Bluetooth Measuring ranges Temperature range control unit Temperature range limiter Voltage Load Current Ground-fault current Heater time alarm elay cycle alarm From 80 C to +700 C in steps of 1K From 60 C to +599 C in steps of 1K (NGC-20-CL-E only) From 50 Vac to 305 Vac From 0.3 A to 30 A From 10 ma to 250 ma (CD/ELCB required due to IEC and/or local regulations) From 1 to 1 x 10 6 hours From 0 to 2 x 10 6 cycl Ordering information DigiTrace NGC-20 control units NGC-20-C-E (Hazardous area approved control unit without safety temperature limiter) 1244-007035 (2.2 kg) NGC-20-CL-E (Hazardous area approved control unit with integrated safety temperature limiter) 1244-007036 (2.3 kg) DigiTrace NGC-20 accessories Temperature sensors MONI-PT100-260/2 or MONI-PT100-EXE-SENSO Support bracket for installation on pipe SB-125 1244-06603 (0.5 kg) Bluetooth enabled handheld programming device with customized DigiTrace software NGC-CMA-EX (Hazardous area approved device for use in Zone 1, 2, 21, 22) 1244-006605 (1.2 kg) NGC-CMA-NH (Industrial grade, not approved for use in hazardous area) 1244-006606 (0.8 kg) 4-5 EN-NGC-20-C-E/CL-E-DS-DOC2210-1-08-2012

Connection diagram (typical) L N to next NGC-20 S485 cable from previous device S485 cable to next device 2nd TD not added for drawing clarity When the device is the last on the communication line install a wire bridge between the - and T terminal as shown by the dotted line TD 2 TD 1 TD LIMITE S485 S485 S S + + T Internal S485 end of line termination resistor Li Lo Ni No Lo No Heater Alarm 250 Vac/3 A Max Heating system PT100 temperature sensor(s) PT100 temperature sensor Only to be used for the LIMITE EN-NGC-20-C-E/CL-E-DS-DOC2210-1-08-2012 5-5