IPAC. Invicta Precision Air Control Floor Standing Range

Similar documents
MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS

IPAC Air Handling Units

Flexible & Innovative. Cooling Solutions

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

APC APPLICATION NOTE #119

Flexible and efficient: Close Climate Control for IT equipment

gforce Units Data Aire and Data Temp Series

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

8-101kW. AlphaCool close control range ADDITIONAL CAPACITIES. NOW AVAILABLE Plus EC fan option kW. Typical applications

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 **

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

Vertical self-contained air conditioner

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 **

DESCRIPTION APPLICATIONS MD800S SUPPLY MODULE

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Chilled Water Precision Air Conditioner for Critical Application

CHILLED WATER DATA ROOM UNITS

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING,

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

MARSTAIR INDEX. Product Description. Cellarator Units Condensing Units 3-6. Condensing Units - Ducted 7

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data)

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

LE Series. Electrode Steam Humidifiers

Close control air conditioning

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

Precision air handling cabinets Ciatronic MICRO/EXPAIR

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

2013 Product Range Precision Air Conditioners (CRAC)

C13-Series Engineering Guide

Liebert. CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Service Step by Step Trouble-Shooting Check-List

EDPAC International Close Control Air Conditioning Products E

Series PS6, Vertical Floor-Mount Units

PRODUCT DOCUMENTATION

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

PRODUCT DOCUMENTATION

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

Blower-YEFB-020-3R-1maxVel

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

Mission Critical Air Conditioning Systems

Series 6, Vertical Floor-Mount Units

System Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact.

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Liebert Datamate: R-407C Parts Manual

DATATECH. Precision air conditioners for technological environments 6 220

AIR CONDITIONERS. RCGROUP SpA fiftycoolyears C_GNR_0113

Key benefits. Why Condair CP3?

DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

A660 Air Conditioning Laboratory Unit

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

NA G µair CONNECT 2

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Series 6, Vertical Floor-Mount Units

AFD Industrial Dehumidifier Series

within a Quality Management System ISO9001 and Environmental Management System ISO Sales Offices CERTIFICATION

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

September, Ductless Split Ceiling Cassette Ductless Mini-Split Models SSD, SSH and SCW

20-120RT Multi-functional Modular Combination High Efficiency & Energy Saving Keeping Technology Cool

Chilled Water 7 to 211 kw

Computer Room Air-Conditioning 60 Hz. Technical Data

Dry desiccant dehumidification systems. Product guide

RHC GAS FIRED HEATING COILS

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

DATA & FACTS Close Control Units Multi-DENCO. Flexible and Efficient

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Chilled Water 7 to 211 kw

ENCLOSURE COOLING. Glossary

HVAC Mandatory Provisions Part II, Page 1

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

next evo cw next evo cw rcgroupairconditioning

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Close Control Air Cooled Twin Circuit Range

Integrated VarIable refrigerant flow ahu/pau (r410a)

Technical Data Ducted Three Phase Split System Air Conditioner

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

NEXT DL NEXT DL. rcgroupairconditioning

Data Aire Series Chilled Water 7 through 50 ton

Product Line Introduction. Karl Zhang Technical support engineer

Transcription:

IPC Invicta Precision ir Control Floor Standing Range

The Invicta Precison ir Control (IPC) range of floor standing units has been developed to satisfy the exacting standards for full function air conditioned environments. IPC Features Modular Design. Energy Efficient. Open rchitecture Control Protocol. Low Cost of Ownership. State of the rt Manufacturing. Designed for 24/7 Year Round Operation. S EN ISO 9001. pplications These units have been specifically designed and developed for a number of industries, including: Commercial Computer Rooms, Server Rooms, Dealing Rooms and Showrooms. Process reas Control Rooms, Electronic Manufacturing, CD Manufacturing and Injection Moulding Facilities. Environmental Control rchive Storage, Museums, Libraries, rt Galleries, Testing & Measurement Laboratories and Textile Laboratories. Telecommunications Internet Farms and Switch Rooms. Industrial Petrochemical, Manufacturing reas and irports. Medical Clean Rooms and Medical & Pharmaceutical Facilities.

Duty Range The IPC range has been developed to provide a flexible duty range of units. Stand alone units currently range from a nominal 15 kw to 80 kw. Master/Slave combinations extend the range for larger applications. Precision ir Control Equipment The IPC floor standing units are in their most basic form available in chilled water or DX cooling only configuration. These systems can either be mounted inside the conditioned space or mounted remotely, with the fan developing external pressure to transport the air to the conditioned space. Units can be manufactured with an upflow or downflow air pattern to enable optimum comfort levels. Depending on the application, heating, dehumidification, humidification and air filtration can also be provided. s well as the standard unit configurations, a variety of options can be factory or site-fitted to customise units to the system requirements. This provides the designer, installer and customer with a system that can precisely match the requirements. Controller The Eaton-Williams controller is a purpose designed LonWorks microprocessor, which fully complies with EEC directives for electromagnetic compatibility (EMC). The controller is powered from a 9 V and 24 V 50 Hz power supply, these are provided via a transformer mounted within the electrical chassis. ll outputs are protected by shrouded fuses. The Controller Hardware Consists of: Display and push-button assembly. Microprocessor controller assembly. The Controller Includes the Following Features as Standard: Temperature and humidity set point adjustment. Dead band adjustment. Proportional band adjustment. larm band adjustment (individually for temperature and humidity). Fault and service alarm volt-free contacts. Winter low pressure switch delay timer adjustment. Start delay timers. Historical alarm logging. Lon network communications. Stand-alone or Master/Slave. Run/Standby and duty rotations. Temperature Control IPC units are designed to operate at room temperatures from 18 C to 30 C as standard and with factory added options can operate outside this range. Temperature can be precisely controlled, with cooling provided by a chilled water system or a DX unit with an external air-cooled condenser (option of water-cooled condenser available). Where heating is required, the alternatives of electric or low pressure hot water heating are available. Humidity Control Where humidity control is required, the IPC unit is factory fitted with the facility whereby the cooling coil is operated below the dew point of the conditioned air to provide dehumidification. To ensure optimum temperature control in conjunction with dehumidification the options of hot gas or electric reheat are available. The unit can also be fitted with a proportional output humidifier to provide clean sterile steam. The humidifier responds to a changing demand using the water level (WL) system of modulation. Output is varied by increasing or decreasing the level of water in the cylinder. decrease in water volume causes less electrical energy (measured in amperes) to pass between the electrodes, transforming less water into steam. n increase in water volume, logically, has the opposite effect. WL can modulate down to 20 % of full output.

ir Quality and Distribution The IPC range is fitted with EU4 filters to provide air quality control, with the option of EU6, EU7 (higher filtration levels are available, but will be located in an external filter section). The units are fitted with a fan/motor combination capable of supplying the design airflow against the external resistance of a typical air distribution system as well as providing a quantity of fresh air into the conditioned space. ll Year Round Operation IPC units are designed to operate 24 hours a day, all year round, in any mode (i.e. cooling/heating/ dehumidification/humidification) and come complete with condenser fan speed and pressure control to avoid problems associated with over condensing during winter cooling. Ease of Maintenance In rugged environments in which air conditioning units are installed it is essential to carry out regular maintenance for optimum performance. s well as using top quality components, ease of maintenance has been designed into these systems. The controller automatically indicates when maintenance is required on individual components and all servicing can be carried out through the front door(s) of the unit. Selecting a System The overall building services design will define the type of cooling system required. s standard, the IPC range is available in three basic systems: Direct expansion cooling with air-cooled condenser. Direct expansion cooling with water-cooled condenser. Chilled water cooling. Cooling, Cooling with Heating or Full ir Conditioning Different applications require different modes of control and the IPC range is available in three basic configurations: Cooling only (cooling unit). Cooling with heating (temperature unit). Cooling with heating and humidification/dehumidification (full /C unit). ir-cooled Condensers matched range of air cooled condensers are available for operation in ambient temperatures up to 35 C. However, for higher ambients, uprated air-cooled condenser(s) can be supplied. Nominal Direct Expansion and Chilled Water Unit Ratings IPC Model 15 22 30 32 40 45 55 60 70 80 Total Cooling (DX) kw 16.0 22.0 30.0 32.0 40.7 46.0 56.0 60.0 70.6 81.4 Gross Sensible Cooling (DX) * kw 14.8 20.9 28.1 29.6 37.4 42.9 52.2 56.2 65.5 74.8 Sensible Heat Ratio (DX) 0.92 0.95 0.94 0.92 0.92 0.93 0.93 0.94 0.93 0.92 Total Cooling (C/W) kw 24.0 33.8 42.5 48.0 59.5 66.5 83.5 85.0 102.0 119.0 Gross Sensible Cooling (C/W) ** kw 18.7 26.0 33.6 37.4 47.0 52.5 66.0 67.2 80.6 94.0 Sensible Heat Ratio (C/W) 78 77 79 78 79 79 79 79 79 79 irflow m 3 /s 1.25 1.70 2.25 2.50 3.20 3.50 4.65 4.50 5.45 6.40 irflow m 3 /h 4500 6120 8100 9000 11520 12600 16020 16200 19620 23040 Standard External Pa 70 70 70 70 70 70 70 70 70 70 Maximum External (Clean Filters) Pa 400 400 400 400 360 400 360 400 360 360 Electrical Heating kw 5 10 10 5 15 10 15 10 15 15 Humidification kg/h 5 9 9 5 9 9 9 9 9 9 Filtration G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 Noise Level d() 55 56 61 58 67.8 63 67 64 70 70 Condenser (For DX System) ICV1-18P ICV1-40P ICV2-40P ICV1-18P ICV2-70P ICV2-40P ICV2-70P ICV2-40P ICV2-70P ICV2-70P ICV1-18P ICV1-18P ICV1-18P ICV2-40P ICV2-40P ICV2-70P Outdoor Unit Noise Level d() 58 58 59 59 59 59 59 59 59 59 * Unit ratings at 24 C / 50 % RH Internal and 35 C External. ** Unit rating at 24 C / 50 % RH and chilled water 7 C Flow / 12 C. Maximum external pressure would be optional via a pulley / motor change (client to specify at time of order). Sound pressure level per cabinet at a distance of 3 m from the unit with floor return and ducted supply. Sound pressure level per condenser at a distance of 3 m from the unit.

irflow Configuration The IPC unit airflow can be configured in order to make site installation as easy as possible. Upflow Units ottom return air inlet, with top outlet air supply (standard). Front return air inlet, with top outlet air supply (factory fit option). ack return air inlet, with top outlet air supply (siteconfigurable). Downflow Units Top return air inlet, with bottom outlet air supply (standard). Front return air inlet, with bottom outlet air supply (factory fit option). ack return air inlet, with bottom outlet air supply (siteconfigurable). variety of header boxes and base plinths can be supplied to suit the above units. Upflow configurations ir ir ir Front ack ottom Downflow configurations Top ack Front ir ir ir

Technical Specifications Pipework connection sizes IPC Model 15 22 30 *32* 40 45* 55* 60* 70* *80* Indoor Liquid Line Connection inch 3/8 1/2 1/2 3/8 3/8 5/8 1/2 3/8 5/8 3/8 1/2 1/2 5/8 1/2 5/8 5/8 Outdoor Liquid Line Connection inch 3/8 1/2 1/2 3/8 3/8 5/8 1/2 3/8 5/8 3/8 1/2 1/2 5/8 1/2 5/8 5/8 Indoor Line Connection inch 1/2 3/4 3/4 1/2 1/2 7/8 3/4 1/2 7/8 1/2 3/4 3/4 7/8 3/4 7/8 7/8 Outdoor Line Connection inch 3/4 7/8 7/8 3/4 3/4 7/8 7/8 3/4 7/8 3/4 7/8 3/4 7/8 7/8 7/8 7/8 C/W Connection Size mm 28 35 35 28 28 42 35 28 42 28 35 35 42 35 42 42 ll pipe connections brazed (standard) options available. * Dual cabinet units have two sets of pipework connections. Pipework line sizes guide IPC Model 15 22 30 32 40 45 55 60 70 80 Up to 10 m Liquid inch 1/2 1/2 5/8 1/2 1/2 3/4 5/8 1/2 3/4 1/2 5/8 5/8 3/4 5/8 3/4 3/4 Pipe Run Length inch 3/4 3/4 7/8 3/4 3/4 1 1/8 7/8 3/4 1 1/8 3/4 7/8 7/8 1 1/8 7/8 1 1/8 1 1/8 10 to 30 m Liquid inch 5/8 5/8 3/4 5/8 5/8 3/4 3/4 5/8 3/4 5/8 3/4 3/4 3/4 3/4 3/4 3/4 Pipe Run Length inch 7/8 7/8 1 1/8 7/8 7/8 1 1/8 1 1/8 7/8 1 1/8 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 30 to 50 m Liquid Inch 5/8 5/8 3/4 5/8 5/8 7/8 3/4 5/8 7/8 5/8 3/4 3/4 7/8 3/4 7/8 7/8 Pipe Run Length inch 7/8 1 1/8 1 1/8 7/8 7/8 1 3/8 1 1/8 7/8 1 3/8 7/8 1 1/8 1 1/8 1 3/8 1 1/8 1 3/8 1 3/8 ll pipe connections brazed (standard) options available. Pipework for sizes guide only, qualified personnel should specify pipework subject to site layout/conditions. Dual cabinet units have two sets of interconnecting pipework. General service connections IPC Model 15 22 30 32 40 45 55 60 70 80 Humidifier Water Feed 15 mm Cu 15 mm Cu 15 mm Cu 15 mm Cu 15 mm Cu Condensate/Humidifier Drain Connection I/D Tube mm 22 2 22 22 2 22 22 2 22 2 22 2 22 2 22 2 22 Fixing Down olts/unit ncillaries mm M6 M6 M6 M6 M6 Power Supply V / ph / Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 Indoor Unit Power Supply Cable Details 5 core 3ph/N/E 5 core 3ph/N/E 5 core 3ph/N/E 5 core 3ph/N/E 5 core 3ph/N/E Outdoor Unit Interconnecting Cables 3 core L/N/E 3 core L/N/E 3 core L/N/E 3 core L/N/E 3 core L/N/E Push-fit connection for copper pipe. Range electrical details IPC Model 15 22 30 32 40 45 55 60 70 80 Fan Motor(s) Compressor(s) Electrical Heater(s) Internal Humidifier Condenser(s) Power Rating kw 0.9 2.0 2.6 0.9 0.9 4.0 2.6 0.9 4.0 0.9 2.6 2.6 4.0 2.6 4.0 4.0 FLC /ph 2.7 5.7 6.2 2.7 2.7 8.3 6.2 2.7 8.3 2.7 6.2 6.2 8.3 6.2 8.3 8.3 Power Rating kw 4.1 6.4 6.8 4.1 4.1 10.4 6.8 4.1 10.4 4.1 6.8 6.8 10.6 6.8 10.6 10.6 FLC /ph 7.9 12.1 13.0 7.9 7.9 16.3 13.0 7.9 16.3 7.9 13.0 13.0 16.3 13.0 16.3 16.3 Power Rating kw 5 10 10 5 15 10 15 10 15 15 FLC /ph 10.4 20.8 20.8 10.4 20.8 20.8 20.8 20.8 20.8 20.8 Power Rating kw 4 6.8 6.8 4 6.8 6.8 6.8 6.8 6.8 6.8 FLC /ph 5.7 10.2 10.2 5.7 10.2 10.2 10.2 10.2 10.2 10.2 Power Rating kw 0.7 1.5 1.5 0.7 0.7 1.5 1.5 0.7 1.5 0.7 1.5 1.5 1.5 1.5 1.5 1.5 FLC /ph 3.2 6.4 6.4 3.2 3.2 6.4 6.4 3.2 6.4 3.2 6.4 6.4 6.4 6.4 6.6 6.6 Total Cooling Max. Running /ph Unit (DX) 13.8 25.5 26.3 27.6 31.8 40.1 45.6 52.7 58.1 63.5 Total Temp Max. Running /ph Unit (DX) 13.8 25.5 26.3 27.6 31.8 40.1 45.6 52.7 58.1 63.5 Total Full /C Max. Running /ph Unit (DX) 23.8 35.5 39.2 37.6 51.8 53.0 65.6 65.6 78.1 83.6 Total Cooling Max. Running /ph Unit (C/W) 3.7 7.2 7.2 7.4 9.3 10.9 13.0 14.4 16.5 18.6 Total Temp Max. Running /ph Unit (C/W) 12.7 26.2 26.2 16.4 29.3 29.9 33.0 33.4 36.5 38.6 Total Full /C Max. Running /ph Unit (C/W) 17.5 36.4 36.4 21.2 39.5 40.1 43.2 43.6 46.7 48.8 Full load currents (FLC) are at standard design conditions. For dual cabinet units add component electrical figures together where appropriate.

Technical Specifications Internal unit dimensions and weights IPC Model 15 22 30 32 40 45 55 60 70 80 Unit Height () mm 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 Unit Width () mm 800 1300 1300 1600 1700 2100 2500 2600 3000 3400 Unit Depth mm 800 800 800 800 800 800 800 800 800 800 Unit Weight kg 270 380 402 520 472 652 722 782 852 916 Internal unit colour S0005 (nearest equivalent RL 7035). Unit configurations IPC 15 IPC 22 IPC 30 IPC 32 IPC 40 INTERCONNECTING POWER ND CONTROL CLING VI SIDE PNEL GLND PLTES OR UNDER FLOOR. IPC 45 DUL CINET UNIT SPLIT LINE. CINETS SHOWN SIDE Y SIDE FOR CLRITY. NOTE: CINETS CN E POSITIONED PRT TO SUIT ROOM LYOUT. DUL CINET UNITS HVE DX OR C/W ND DRIN CONNECTIONS TO ECH CINET. IPC 55 IPC 60 IPC 70 IPC 80 ICV condenser dimensions and weights ICV Model ICV1-18P ICV1-40P ICV2-40P ICV2-70P ICV Condenser Height () mm 855 875 875 875 ICV Condenser Width () mm 948 2023 2023 2023 ICV Condenser Depth (C) mm 772 772 772 1000 ICV Condenser Weight mm 47 50 54 66 Please note: the condensers can be used in both horizontal and vertical airflow modes. Condensers are fitted with isolator and pressure actuated fan speed controller as standard. SIDE VIEW Pipework Connections Pipework Connections Pipework Connections PLN VIEW C C C ICV1-18P ICV1-40P ICV2-40P ICV2-70P

PRODUCT RNGES ir-cooled & Water-cooled Liquid Chillers Packaged Roof-Top Units Full Range of ir Handling Units Fan Coil Units Package Telecommunications Units Fresh ir Units Condensing Units ir Cooled Condensers Low Temperature Cassettes Cellar & Storage Low Temperature Cooling Units Packaged In-Wall Units Stand-alone Humidifiers OEM Process Cooling Control Units Custom Designed Packages marketing@dafnia.com www.dafnia.com U DHI DUI JFZ MUSCT DOH 3 UE +971 2 5557351 +971 4 3352995 +971 4 8831401 OMN +968 24 750205 QTR +974 44150543 3 0413100(E) IPC /11.02/2