VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

Similar documents
VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

High efficiency, cast-iron gas boiler

Peerless Boilers. Series MI. Residential Gas Boilers

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Columbia Boiler Company

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Peerless Boilers. Peerless Pinnacle. High Efficiency Stainless Steel Boilers

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh

User s Information Manual

Raypak Residential Products

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

User s Information Manual

TABLE OF CONTENTS BRADFORD WHITE BOILERS

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Replacement parts EG/PEG

Intelligent ways to save fuel heating your Commercial building. Caravan Modular Boiler System. CHS Multiple Boiler System

Product Data BW9 WATER BOILER SERIES B

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Suggested Specifications Prestige Excellence 110

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

TECHNICAL SPECIFICATIONS

Boiler & Water Heater

High Efficiency Commercial Gas Water Heaters

G6RC Series TECHNICAL SPECIFICATIONS

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

State of New Jersey BOARD OF PUBLIC UTILITIES 44 SO. CLINTON STREET 7 TH FLOOR P.O. BOX 350 TRENTON, NEW JERSEY

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

MASCOT II. Gas-Fired Wall-Mounted Combination Boiler & Water Heater

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

95% SERIES 2 HEAT ONLY AND COMBINATION GAS WALL MOUNT BOILERS. Bringing. heat and hot water into perfect Balance

CATALOG: HVAC - Gas Space Unit Heating

TECHNICAL SPECIFICATIONS

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

Contents. Hazard definitions

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

SECTION HEATING BOILERS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

SLANT/FIN BOILERS TRADE PRICE BOOK

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

Burner Comparisons. Typical Competitor s Burner

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Greenstar The World's Best Selling Condensing Boiler System

Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

TECHNICAL SPECIFICATIONS

LAARS PENNANT. Economical efficiency for greater savings

STEAM / GAS APPLICATION GUIDE

A. Product Data: Include rated capacities, furnished specialties and accessories.

User s Information Manual

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

G124X - G234X - G334X Atmospheric Gas Boilers

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Date: Project #: Engineer: Prepared By: Bid Date:

GARAGE / WORKSHOP INFRARED HEATERS

Models CB-45 through CB-180 Cast-iron Hot Water Boilers Gas-fired Sealed Combustion Direct Vent, Category I, or Category IV Venting Flexibility

ES2 Boiler 85% AFUE. Limited Lifetime Warranty! boiler control. option. option card. control system GREATER ENERGY SAVINGS. Cast Iron Water Boiler

EUTECTIC EC-10DV Series

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

WM97+ Wall Mount Boiler

Commercial Tankless Rack System

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

DOM-5. Domestic Hot Water Heaters & Boilers

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

Commercial Tankless Rack System

FG7T (C and L Series)

Commercial Tankless Rack System

C1210ES Tankless Water Heater

8+* Bulletin No November 1997

G215 G315 Cast Iron Residential Boilers

EUTECTIC EC-20 OIL-FIRED WATER BOILERS/NO. 2 OIL ASSEMBLY INSTRUCTIONS EUTECTIC EC-20 ASSEMBLY GUIDE

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

FSB Series II Gas-Fired Hot Water Induced Draft Boilers

INSTALLATION AND OPERATING INSTRUCTIONS

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

G515/7 Cast Iron Boiler

Transcription:

VICTORYVSPH VICTORY VSPH Cast-iron sealed combustion, direct vent gas boiler Cast-iron sealed combustion, direct vent gas boiler THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION, RELIABILITY AND ECONOMY.

VICTORYVSPH SEALED COMBUSTION, DIRECT VENT GAS BOILER Modern home heating with the safety, comfort and versatility of sealed combustion. Economically priced No chimney required Operates in total isolation from household air. Outdoor air used for combustion. Reliable, advanced design, high efficiency cast-iron heat exchanger AFUE to 86.% saves energy Energy Star qualified Near zero CO emissions Five sizes 60,000 to 80,000 Btuh AGA input A smart choice for homebuilders Venting versatility no chimney required The sealed combustion Victory VSPH boiler does not require a chimney. It fits easily in a closet size space and may be vented directly through a wall. Since it draws combustion air directly from the outdoors, its fresh air requirements will not interfere with interior design. It s ideal for homes, apartments, condos and any application where a chimney may not be practical or where an old chimney has deteriorated. It saves construction costs and allows more living space. A wide variety of options permit you to select the most practical and economical venting method. Consult installation instructions for complete details. The Victory VSPH boiler operates in total isolation from household air. The combustion process is sealed inside the boiler, with intake air and exhaust pipes connected directly to the outdoors. Venting may be through the wall or through the roof (far right).

Comfort and peace of mind for your family Heat your home with confidence with a modern new Victory VSPH boiler from Slant/Fin. High efficiency operation keeps fuel costs low. And its sealed combustion design gives you remarkable comfort, safety and peace of mind. The Victory VSPH runs so quietly, you will hardly know it s on, even if it is located near your living area. When installed with an optional Slant/Fin indirect water heater, you can also enjoy abundant hot water for your kitchen, bath and laundry. Sealed combustion makes your home more comfortable Your home will be more comfortable with a Victory VSPH boiler because it does not use household air for combustion. Two -inch pipes connect the boiler through an exterior wall to the outdoors. One pipe draws in fresh outside air for combustion while the other expels exhaust directly to the outdoors, without ever disrupting the comfort of your living area. An ordinary natural draft boiler typically draws 0 to 60 cubic feet of warm household air per minute from your living areas. This air is replaced by cold outside air that is literally sucked in through tiny cracks and openings around doors, windows and elsewhere. This makes you chilly and causes your boiler to run longer, resulting in higher fuel bills. The Victory VSPH boiler s combustion process is totally isolated from the air in your home. A properly installed system has no open flame and no vent system component that permits exhaust or flame to back up into the house. When the alternative nondirect venting method is chosen, inside air is used for combustion. Cast-iron design for proven long life and reliability The Victory VSPH is America s best built sealed combustion gas boiler -- backed by a lifetime limited warranty. Cast-iron is recognized by heating professionals everywhere as the longest lasting, most durable heat exchanger material. Boilers made with stainless steel, aluminum or copper are typically more prone to service problems and, reflecting their relatively short life expectancy, generally carry a much shorter warranty. Ordinary boilers consume warm household air which causes infiltration of chilly outdoor air to replace it. High efficiency keeps fuel costs low All Victory VSPH models have been awarded Energy Star certification by the US government for their fuel saving performance. With AFUE to 86.%, Victory VSPH provides high efficiency heating that will keep fuel costs low. A new Victory VSPH boiler can save 0% or more compared to a typical old boiler operating at 60% efficiency.

Victory VSPH Built for performance and reliability Advanced design cast-iron heat exchanger extends boiler life The cast-iron boiler sections are produced on state-of-the-art computerized machining centers to extremely critical tolerances. Superior heat transfer properties permit use of smaller, more compact heat exchanger sections. The flue passage design, thermal pin pattern and consistent wall thickness ensure uniform heat transfer with less thermal strain and metal fatigue. Avoid leaks with durable metal push nipples Only metal push nipples are used to join the castiron sections. These push nipples expand and contract uniformly with the cast-iron sections for superior, leak-free performance and longer life. In many ordinary boilers, cheaper rubber or plastic gaskets are substituted for metal push nipples and could deteriorate and leak. Speedy, self-sealing vent connection Flue connector has an integral seal that is compatible with Saf-T Vent EZ Seal vent components. Integral seals speed vent installation. With EZ Seal components, no RTV sealant and no curing time are required, so the boiler may be started immediately. EZ Seal vent components won t seat incorrectly, so you reduce the risk of accidental flue gas or condensate leakage. For use of other vent component brands, see installation instructions. Air intake utilizes PVC or galvanized pipe. Unitized air intake-vent terminal Designed specifically for use with the Victory VSPH boiler, the combination air intake-vent terminal is versatile and attractive. It fits walls from " to " thick. Included with every boiler. Integrated boiler control optimizes boiler performance The electronic control was designed specifically to optimize the operation of the Victory VSPH boiler. It monitors the status of boiler components and controls the sequence of operation, including preand post-purge periods, trial for ignition and lockout. Five indicator lights verify normal operation and provide diagnostic information when flashing. Increased efficiency with insulated base assembly The Victory VSPH base assembly is constructed of heavy gauge aluminized steel. Thick refractory insulation surrounds the combustion chamber, increasing efficiency. One piece stainless steel burners with special port construction resist flame lift and flashback. Saf-T Vent EZ Seal is a registered trademark of Heat-fab, Inc.

VICTORYVSPH Cast-iron, sealed combustion, direct vent gas boiler Horizontal flue discharge Power vent blower Insulated jacket Cast-iron heat exchanger Brand name controls Thermal pins Junction box Metal push nipples Insulated base Long life stainless steel burners (not visible) Intake air difuser Gas valve Combustion air intake port Rollout safety switch Lifetime Limited Warranty Victory VSPH boilers are so reliable they come with a lifetime limited warranty. Combustion air intake chamber

Installer-friendly features speed installation and service The Victory VSPH boiler installs anyplace with access to an outside wall or roof for venting -- basement, utility closet or even a garage. Since it does not require a chimney, it s ideal for replacements when an old chimney is inadequate or in need of repair. It s engineered with installer friendly features to speed installation and service: 4 6 7 8 9 0 Horizontal flue discharge components are factory installed to save field assembly. -inch flue connector with integral adapter for easy connection to stainless steel venting. Integral self-seal when used with EZ Seal components. Condensate drain is built into the flue discharge assembly. Drain tube for condensate is factory installed and pre-configured with water trap. Quick connect wiring speeds service, prevents miswiring. Integrated boiler control with built-in diagnostics engineered by Slant/Fin to optimize VSPH boiler operation. Diagnostic indicator lights speed troubleshooting. Intermittent pilot spark ignition saves energy. Field convertible gas valve for natural-to-propane gas. Junction box for line voltage facilitates wiring of shut-off switch. Pressure switch functions at all altitudes. Controls, circulator pump, inducer and other trim are top quality brand names that are widely available to heating professionals and easy to service. 4 9 4 0 4 Pressure-temperature gauge located for easy viewing. Circulator harness is long enough for supply or return mounting. -inch combustion air intake connector for PVC or galvanized pipe. 6 7 8 Condensate drain is built into flue discharge assembly. Easy to access up-front controls. Lift-off front cover.

Ratings VICTORYVSPH SEALED COMBUSTION GAS BOILER RATINGS FOR NATURAL AND L.P. GAS RATINGS FOR WATER A.G.A. D.O.E. NET I=B=R NET MODEL No. INPUT CAPACITY WATER WATER EFFICIENCY (Btuh) (Btuh) (Btuh) (Sq. ft) (A.F.U.E.) VSPH-60 60,000,000 4,000 00 86.% VSPH-90 90,000 78,000 68,000 4 8.7% VSPH-0 0,000 0,000 90,000 600 8.% VSPH-0 0,000 8,000,000 740 8.% VSPH-80 80,000 4,000 4,000 89 8.% MAXIMUM EQUIVALENT FLUE LENGTH VSPH-60, 90 & 0: 40 ft. VSPH-0: ft. VSPH-80: ft. May differ for certain vent system manufacturers and altitudes. Vent terminal does not effect calculation of total equivalent length. See installation instructions, Pub. VSPH-40. Ratings must be reduced by 4% at,000 feet elevation and an additional 4% for every additional,000 feet elevation over,000 feet. Net ratings shown include allowance from normal piping loss and pick-up load. For installations having unusual piping and pick-up requirements, additional allowances should be made before selecting the size of boiler required. Ratings are based on a piping and pick-up factor.. Based on heat emission rate of 0 Btu per square foot. Note: All VSPH boilers are tested and rated for capacity under the U.S. Dept. of Energy (D.O.E.) Test Procedure for Boilers Maximum ASME working pressure: 0 psi.. Equipment PACKAGED WATER BOILER includes pre-assembled cast-iron heat exchanger with built-in air eliminator, base, pre-assembled insulated flush jacket, gas burners, gas orifices and manifold assembly, combination gas valve, including manual shut-off, pressure regulator and pilot adjustment, integrated boiler control with built-in diagnostics, electronic intermittent pilot ignition system, pressure and temperature gauge, pressure relief valve (ASME), circulator -/4", drain cock, inducer assembly, air flow proving Dimensions Dotted gas piping by others Pressure relief valve " FPT supply Install manual main shutoff valve ' above floor when required by local code 4" to air eliminating system switch, built-in condensate drain, trap and stainless steel vent pipe adapter, unitized vent/air intake terminal, rollout safety switch. For propane, specify when ordering. OPTIONAL EQUIPMENT: 4 volt thermostat. Air package consisting of diaphragm expansion tank, fill and pressure reducing valve, and automatic air vent. Combustible floor kit. AL 9-4C stainless steel venting material. " dia. vent connector 8 4" (See note) 4" Drain 8" (See note) LEFT SIDE Sediment trap required Supply water tapping " Circulator return flange* 4" Gas tapping, natural or propane " A Jacket B FRONT AL 9-4C is a registered trademark of Allegheny Ludlum Corp. *When not equipped with circulator, boiler " return tapping. 0 " (See note) Press/temp gauge Junction box " return tapping 4" cir. flange RIGHT SIDE Vent connector 8 " (See note) NOTE: Height dimensions increase by " and depth increases to 8 " when combustible floor kit is used. Dimensions VSPH-60 VSPH-90 VSPH-0 VSPH-0 VSPH-80 A 8" 4 8" 7 8" 0 8" 8" B 7 8" 0 8" 8" 6 8" 9 8" Victory VSPH boiler minimum clearances for combustible construction (See installation instructions for further details.) Before purchasing this appliance read important energy costs and efficiency information available from your contractor.

Make your house a more comfortable home With a Victory VSPH boiler at the heart of your heating system, you can enjoy deluxe heating comfort all around your home. A Victory VSPH boiler can be installed to provide heating energy for any or all of these hydronic heating systems: 4 Zoned heating with Slant/Fin hot water baseboard and individual room temperature controls. Warm floors with Terra Therma radiant heating by Slant/Fin. Slant/Fin hot water fan-convection heaters under cabinets or stairs. Hot water with a high volume Slant/Fin indirect-fired water heater. Snow melting for driveway and sidewalks with Terra Therma radiant tubing. 4 Zone your heating system for even greater fuel savings. By dividing your home into separate heating zones, you can save energy by heating only those areas you re using. Depending on your existing piping arrangement, it may be quite simple to zone your system. More hot water for your kitchen, bath and laundry. For a large reserve of hot water for your family all year long, your installer can provide a Slant/Fin Model WH indirect-fired water heater. It s connected just like a heating zone to the Victory VSPH boiler and will store between 0 and 80 gallons of hot water. Tapping the boiler s heating capacity, the Slant/Fin water heater offers far better efficiency, faster recovery and longer life than an ordinary direct-fired water heater. The 40 gallon model, for instance, delivers 9 gallons of hot water per hour! SLANT/FIN CORPORATION, Greenvale, N.Y. 48 Phone: (6) 484-600 FAX: (6) 484-9 In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario www.slantfin.com Slant/Fin Corp. 00. Printed in the U.S.A. 60. Publication No. VSPH-0.