PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Similar documents
CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

DUST EXTRACTOR MODEL No: CDE1000

SUBMERSIBLE DIRTY WATER PUMP

DEVIL CERAMIC SPACE HEATERS

OPERATION & MAINTENANCE INSTRUCTIONS

ELECTRIC ASH CAN Model: CVACASH500 Part No:

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

MOBILE PARTS WASHER MODEL No: CWM20

900W OIL FILLED RADIATOR

3KW ELECTRIC FAN HEATER

2.8KW ELECTRIC FAN HEATER

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

2 KW OIL FILLED RADIATOR

COLD WATER WASHER OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. ELS140, 140R & ELS150. Part Nos , &

ORIGINAL INSTRUCTIONS

WET & DRY VACUUM CLEANERS

20 LITRE DEHUMIDIFIER

DUST EXTRACTOR MODEL No: CDE7B

5KW ELECTRIC FAN HEATER

NON-SUBMERSIBLE WATER PUMP

15KW ELECTRIC FAN HEATER

18 INCH HIGH VELOCITY FLOOR FAN

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

GAS HEATERS Models: Little Devil (inc ss), Devil 650/660(ss), Devil 850/860(ss), Devil 1250/1260(ss), Devil 1850, Devil 3000 & Devil 3150

2 KW OIL FILLED RADIATOR

PARTS WASHER Model: CW2D Part No:

150MM ELECTRIC EARTH BORER

ELECTRIC FAN HEATERS

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

OPERATING & MAINTENANCE INSTRUCTIONS

30KW ELECTRIC FAN HEATER

24 & 30 INCH DRUM FANS

OPERATING & MAINTENANCE INSTRUCTIONS

MODEL NO: CW2D PART NO: OPERATING & MAINTENANCE INSTRUCTIONS

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

CEMENT MIXER MODEL NO: CCM134L OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC0514

PARTS WASHER Model: CW1D Part No:

DIESEL/PARAFFIN HEATERS

PARAFFIN/DIESEL HEATER

PARAFFIN/DIESEL HEATERS

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

PORTABLE AIR CONDITIONER MODEL NO: AC9000

HOT AIR GUN MODEL NO: CHG1500D USER INSTRUCTIONS PART NO: GC0414

Mobile Air Conditioner Instruction Manual Model TC-N9KM

1/3 SHEET ORBITAL SANDER MODEL No. COS200

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

GAS HEATERS MODEL NOS: 900DV,1600DV & 2100DV PART NOS: , & USER INSTRUCTIONS ORIGINAL INSTRUCTIONS LS ISS 1

DIRTY WATER SUBMERSIBLE PUMP

Model Nos CBM100SS, 130SS, 250SS, 240 & 240E CPE100P, 100TF, 120 & 130SS HANDY PUMP 2 OPERATING & MAINTENANCE INSTRUCTIONS 0406

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Heated Display. Instruction manual. Model: CW147 / CW148

Model No: Little Devil II (inc ss)

Work-Shed Vac 1100 Watt

DIRTY WATER SUBMERSIBLE PUMP KIT

INFRARED DIESEL HEATER

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

submersible water pumps

HOT WASHER MODEL NO: KING150

GAS HEATERS MODEL NOS: DEVIL 700, 900/910SS,1600/ 1610SS & 2100 PART NOS: , , , , , &

Contents. Warning: Installation... 2 Warning: Operation...2 Warning: Disposal...3

Sip Vacuum Cleaner 1400/35 Wet & Dry

SUBMERSIBLE WATER PUMP

PJ130S High Pressure Cleaner

DIRTY WATER SUBMERSIBLE PUMP

APW-VAP-150P High Pressure Cleaner Operator Manual

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Vacuum Cleaner MC-E3003 MC-E3001. Operating Instructions. Model No.

Built-in Gas Hob CZ55554 CZ55571

2 IN 1 SUBMERSIBLE PUMP

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

CLEAN WATER SUBMERSIBLE PUMP

K 3.97 M. Specifications or visit our website: In USA call: Part No

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

Operating Instructions

DUST/CHIP EXTRACTOR OPERATING & MAINTENANCE. MODEL No. CDE7B INSTRUCTIONS. Part Part No

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

K Specifications. Max. Water Volume

POWER WASHER MODEL NO: JET 8000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

K Specifications. Max. Water Volume

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

Model K 520 M Part No

Blender. Instruction manual. Model Modèle Modell Modello Modelo Malli: CR836/DR825


Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

PORTABLE AIR CONDITIONER MODEL NO: AC7000

Spiral Dough Mixer. Instruction manual. Model: CP821

Cabinet Refrigerators/Freezers Instruction manual

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

Your Blast Vac Pro. Your Blast Vac Pro

INSTRUCTION MANUAL Model: SU3022

Compact Cyclonic Bagless Upright Vacuum Cleaner

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

USE & CARE MANUAL CONTEMPORARY ELECTRIC FIREPLACE SUITE. CO9144 V3_080714

Transcription:

PUDDLE PUMP PUDDLE PUMP MODEL No: PSP125 Part No: 7230692 OPERATION & MAINTENANCE INSTRUCTIONS 1007

SPECIFICATIONS Model number... PSP125 Rated voltage... 230VAC 50Hz Input power... 293 Watts Maximum delivery capacity... 125 litres per minute Maximum head... 10.2 metres Maximum particle size... 3 mm Maximum Depth... 7 meters Min. water level for operation... 2-3 mm Power cable length... 10 metres Weight (approx.)... 4.83 kg with cable Part Number... 7230692 Please note that the details and specifications contained herein, are correct at the time of going to print. However CLARKE International reserve the right to change specifications at any time without prior notice. Always consult the machine s data plate When disposing of this product, do not dispose of with general waste. It must be disposed of according to the laws governing Waste Electrical and Electronic equipment, at a recognised disposal facility. 2

Thank you for purchasing this CLARKE puddle pump. Before using the pump, please read this manual thoroughly and follow the instructions carefully, in doing so you will ensure the safety of yourself and that of others around you, and you can look forward it giving long and satisfactory service. GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights. CONTENTS Specifications... 2 Guarantee... 3 Contents... 3 Safety Instructions... 4 Electrical Connections... 5 Parts Identification... 6 Recommended Uses... 7 Preparation... 8 Using The Puddle Pump... 9 Cleaning and Maintainence... 10 Troubleshooting... 10 3

SAFETY INSTRUCTIONS KEEP CHILDREN AWAY: Do not allow children to touch the puddle pump, cables or connections. Visitors should be kept away from the work area. STORE IDLE TOOLS: When not in use, the puddle pump should be stored in a dry, secure place out of the reach of children. DISCONNECT TOOLS: Disconnect the puddle pump from the mains supply when not in use, or when making adjustments etc. REPAIRS: Have the puddle pump repaired by a qualified person. STAY ALERT: Watch what you are doing. Use common sense and caution. Never operate the puddle pump when you are tired. DO NOT ABUSE THE MAINS LEAD: Never carry the puddle pump by the mains lead or pull it to disconnect it from the mains socket. Keep the mains lead away from heat, oil and sharp edges. Always check the plug, mains cable and float switch cable for damage prior to use. Do NOT use if damaged. Refer to qualified service personnel for repair. If you have to use an extension lead with this product, it must be designed for outdoor use and incorporate a cable suitable for use with Class I appliances. USE A RESIDUAL CURRENT DEVICE: To provide personal protection against harmful electric current, the puddle pump must be supplied through a high sensitivity residual current device (RCD) with a rated residual operating current not exceeding 30mA. POWER LEAD: If you need to lower the pump into a shaft or well, Tie rope round the handle and lower the pump using the rope. Do not lower the pump using the mains lead. SWIMMING POOLS: If the pump is being used to drain swimming pools, ensure thet no children or animals are in the pool whenever the pump is being used. 4

ELECTRICAL CONNECTIONS Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch. WARNING! THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in the mains lead are coloured in accordance with the following code: Green & Yellow - Earth Blue - Neutral Brown - Live As the colours of the flexible lead of this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows: Connect GREEN & YELLOW cord to terminal marked with a letter E or Earth symbol or coloured GREEN or GREEN & YELLOW. Connect BROWN cord to terminal marked with a letter L or coloured RED. Connect BLUE cord to terminal marked with a letter N or coloured BLACK. If this appliance is fitted with a plug which is moulded onto the electric cable (i.e. non-rewireable) please note: 1. The plug must be thrown away if it is cut from the electric cable. There is a danger of electric shock if it is subsequently inserted into a socket outlet. 2. Never use the plug without the fuse cover fitted. 3. When replacing a detachable fuse carrier, ensure the correct replacement is used (as indicated by marking or colour code). 4. Replacement fuse covers can be obtained from your local dealer or most electrical stockists. FUSE RATING The fuse in the plug must be replaced with one of the same rating (13 amps) and this replacement must be ASTA approved to BS1362. We strongly recommend that this machine is connected to the mains supply via a Residual Current Device (RCD) If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself. 5

PARTS IDENTIFICATION Multi hose fitting Carry Handle Control Switch Automatic (A) / Manual (M) Open (O) - See Maintenance Water Outlet Motor Housing Suction Base 6

RECOMMENDED USES The recommended uses for this pump are: Drainage after flooding The transfer of liquids Drainage of containers Taking water from wells and shafts Liquids that CAN be pumped: Clean water Contaminated water (maximum particle size 3 mm) Note: always consider the outlet hose diameter Swimming pool water Note: After pumping chlorinated water or other liquids containing additives, the pump should be thoroughly rinsed with clean water Soapy water Liquids that MUST NOT be pumped are: Corrosive substances Combustible or explosive substances (petrol, thinners etc.) Fats, oils or salts Waste from toilets or urinals This puddle pump is not designed for circulating operations (i.e. water fountain). 7

PREPARATION CONNECTING THE OUTLET HOSE WARNING! ENSURE THAT THE PUDDLE PUMP IS DISCONNECTED FROM THE MAINS POWER SUPPLY BEFORE CONNECTING THE HOSE. NOTE: The outlet hose is not supplied with the puddle pump. The puddle pump is supplied with a multi hose adapter(as illustrated), for use with 25 mm (1 ) and 38 mm (1-1/2 ) hoses, IMPORTANT! When screwing on the adapter, ensure the non-return valve is correcly located so that the flap opens upwards. The multi hose adapter allows hose to be attached using hose clips or screw-on adapters. If you wish to use a 1 BSP hose adapter (for 1 dia. hose), cut the multi hose adapter at point A. If you wish to use a 1-1/4 BSP hose adapter (for 1-1/2 dia. hose), cut the multi hose adapter at point C. If you wish to connect a 1 hose using a hose clip, simply attach it to the end of the adapter. If you wish to connect a 1-1/2 hose using a hose clip, cut the adapter at point B We strongly recommend that you connect the outlet to the 1-1/2 diameter, as any restrictions will reduce capacity, and put additional strain on the motor. NOTE: Please bear in mind that a hose adapter requires the use of a rubber washer, and the point at which the multi hose adapter is cut (points A and C), must be perfectly clean and square. 8

USING THE PUDDLE PUMP WARNING! BEFORE USING THE PUDDLE PUMP, CHECK TO MAKE SURE THAT IT IS NOT DAMAGED. DO NOT USE A DAMAGED PUMP. REFER TO QUALIFIED SERVICE PERSONNEL. 1 Connect an outlet hose. See page 8. Make sure the outlet hose is clear of obstructions and not kinked. 2 The pumps are completely submersible, and should be placed in a vertical position, on a solid flat surface. If this is not available, sit the pump a solid surface, eg. house bricks, but ensure they are not likely to shift. IMPORTANT: ALWAYS RAISE AND LOWER THE PUMP USING A ROPE ATTACHED TO THE LIFTING HANDLE, NEVER BY THE POWER CABLE. 3 Connect the mains power cable to a high sensitivity residual current device (RCD) with a tripping current of <30mA to provide personal protection against harmful electric current. 4 Switch the mains power supply on, and place the pump into the water you want to drain. The pump will automatically switch on whenever the water depth is above 85 mm. 5 The pump will begin to drain water to a predetermined depth of 25mm. 6 To drain down further (to a height of 2-3 mm) or if the water depth is less then 85 mm, set the control switch to the M (manual) position. The pump is fitted with a thermal cut out to protect the motor from overheating. If the thermal cut out activates, the motor will automatically switch back on when it has cooled down sufficiently. 7 When the pumping is finished, switch off and disconnect from the mains power supply. WARNING! DO NOT ALLOW THE PUMP TO RUN DRY. IF THE PUMP IS RUN DRY, INCREASED WEAR WILL OCCUR AND CAUSE DAMAGE TO THE PUMP. SIMILARLY, DO NOT ALLOW THE PUMP TO RUN FOR MORE THAN 10 MINUTES IF THE DELIVERY SIDE BECOMES BLOCKED AS THIS MAY CAUSE DAMAGE TO THE PUMP. 9

CLEANING AND MAINTENANCE WARNING! MAKE SURE THAT THE PUDDLE PUMP IS DISCONNECTED FROM THE MAINS SUPPLY BEFORE STARTING ANY CLEANING, OR MAINTENANCE PROCEDURES. Always keep the body of the pump, clean and free from dirt, sediment and debris. If the base becomes clogged it must be disconnected from the mains and clean the base. To gain access to the float compartment to check float functioning, and to clean the compartment etc., push the control switch fully down to the O position and pull off the cover. TROUBLE SHOOTING PROBLEM Pump is running but does not deliver Pump does not start or stop during operation. Pump runs, but output suddenly decreases PROBABLE CAUSE Outlet hose blocked or kinked. Air locks in the suction base. Thermal cut out has activated due to overheating. No Power. Base is clogged. 10 REMEDY Unblock or straighten outlet hose. Allow the pump to run for 1 minute. Allow to cool then disconnect from the mains. Make sure that there are no blockages. Check fuses and electrical connections. Disconnect from the mains and clean the base.