EVALUATION OF SWINE FACILITIES VENTILATION

Similar documents
Control Strategies and Considerations for Livestock and Other Farm Buildings

Ventilation Basics How Do Your Pigs Feel? Amy Woods, DVM Rensselaer Swine Services, P.C.

SowBridge. Basic Environmental Factors & Their Effects on Pigs. Importance of Ventilation for Pig Comfort

Manure Pit Ventilation in Confinement Livestock Buildings

Select an agricultural ventilation fan for the

In-Field Quantification of Fan Performance in Tunnel-Ventilated Freestall Barns ABSTRACT INTRODUCTION

Cooling Systems for Georgia Dairy Cattle. Dr. John W. Worley, Extension Engineer

Minimum Ventilation to Maximise Broiler Farm Performance. Ing.. Winfridus Bakker Cobb-Vantress

HOG FINISHING FACILITY PERFORMANCE

9/5/12. Emergency Thermostats Is this your override thermostat? Verify Emergency Equipment. Routine Test and Written History of Test

Chore-Time Fan Guide For Tunnel and Other Applications

ENVIRONMENTAL CONTROL FOR CONFINEMENT LIVESTOCK HOUSING

Ventilate Your Swine Nursery Building

Considering Filtration. Austin Baker Ventilation Director Hog Slat, Inc

Basic Ventilation Considerations for Livestock or Poultry Housing

, 'I... " ENTILATION FOR SWINE / I / / I / I / UNIVERSITY OF flunois / I / SGRICULTUR~.uBRM~ '" ""'... I I \ / I I. , I \ CIRCULA~~G COpy I 1// 1\\

Managing Your Unseen Employee: The Ventilation System. The Pig and It s Environment. Keeping Pigs Eating in Hot Weather

RFMA 2016 March 13 15, 2016

Cooling Load Analysis and Computation Worksheet

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Cooling Load Analysis and Computation Worksheet Answers Part 1 Psychrometrics

WCD-1. Evaporative Cooling Modules. WCD Series. Alton. Keeps You. Cool

The Use of Evaporative Cooling Panels in Tie Stall Dairy Barns

Small Business Energy Solutions Agriculture Worksheet

GENERAL OBSERVATIONS FROM THE PHES EVALUATIONS TO DATE AVERAGE ANNUAL PROPANE USE

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

Heat Exchangers in Swine Facilities

Unico Training. Class for R E Michel Salesmen

Dairy Housing Ventilation Options for Free-Stall Barns H.K. House, P.Eng.

Facility Maintenance and Modernization

Design and Management. Managing Your Unseen Employee: The Ventilation System

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

EDSTROM Cooling Systems for Swine

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Outline. Mixing fans / Cooling fans. Ventilation means air must. Ventilation. Energy Efficiency for Animal Housing. Environmental Control Systems

Enclosure Temperature Control

Swine & Poultry Ventilation - Controllers

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

INVESTIGATION FINDINGS III IMPACT OF INADEQUATE VENTILATION AND DISCHARGE SYSTEMS

Installation, Operation, and Maintenance Information

Energy Efficient Houses. The majority of electricity is used by: tunnel fans during hot weather, and, by lights during cold weather.

CHAPTER IV AIR DISTRIBUTION AND BALANCE

IBIS INTERNATIONAL, INC. DESIGN STANDARDS FOR DUCTING OF EQUIPMENT

Broiler Ventilation Requirements In Response To Higher Welfare Standards. Bernard Green

Ventilation System Description. September 8, 2000 HETA

Acknowledgements. Copyright 2005, Aviagen, Inc., all rights reserved.

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

TPA 2018 Educational Seminar

Breezair RPA Series Installation Manual

Unit 4: Science and Materials in Construction and the Built Environment. Thermal Comfort

u i etai re.com

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Greenhouse Temperature Management

The Corona air inlet TECHNICAL SPECIFICATIONS

Selecting Fans and Determining Airflow for Grain Drying and Storage

Introduction to Fans. The Basics of Fan Principles and Terminology

Evaluation Report 509

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

*RENTAL* Explosion Proof Portacool Portable Evaporative Cooler - C1D1 - Water Mist Cooler - 30" OD

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Enclosure Temperature Control

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Alabama Poultry Engineering and Economics

Construction, Insulation, and Ventilation of Game Bird Facilities 1

HEPASilent Air Purification Systems. Clean air is a human right

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

KCC Centrifugal Fan Air Cooled Condensers

COMPRESSED AIR SOLUTIONS REGARDING PNEUMATIC CONTROL SYSTEMS

GreenJet Transfer Fans

Ambient Weather WS-DP02 Digital Psychrometer with Temperature, Humidity, Heat Index, Dew Point, Wet Bulb Temperature and Clock User Manual

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

Novel Livestock Housing Webinar A Novel Approach to Confined Calf Barn Ventilation

Evaporative Cooling Systems

Checklists LAUNDRY GREENKEYGLOBAL.COM

Manual for MC21A SETUP INSTRUCTIONS

AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking...

Frequently Asked Questions

GARAGE / WORKSHOP INFRARED HEATERS

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Humidity Control Design Tips. R. Mark Nunnelly, PE, CxA, LEED AP President

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

HEPASilent Air Purification Systems. Clean air is a human right

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

LOW PROFILE UNIT COOLER

Air-Handling System Cooling Options

How to Take Basic Readings to Show Energy Efficiency

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Fan Selection. and Energy Savings

LOW PROFILE UNIT COOLER

Fans: Features and Analysis

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016

State-Of-The-Art Developments to Save Energy in Coating Drying. Bob Bates, P.Eng Metso Paper

MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

Displacement Ventilation

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Transcription:

EVALUATION OF SWINE FACILITIES VENTILATION Dr. Steven Matthis Sampson Community College Animal Science Technology Department Clinton, NC 28329-0318 Email: smatthis@sampsoncc.edu Introduction Ventilation has become increasingly complex in the past five to ten years. New and improved methods of ventilating the pigs environment are continually being introduced into the swine equipment market. The continuous changes in the methods and equipment are causing problems in the area of production and environmental management. Any given swine unit could have multiple types of control units, fans and inlets. Operation, management and maintenance of multiple types of equipment can be overwhelming to an operator, owner or production manager. In the next section of lab exercises, the following ventilation concepts will be discussed: The Lab exercise sheets are attached. The printed documents are intended to be used in the hands lab experiments. How to determine if the equipment is operating at full capacity. o Fans o Inlets o Evaporative Cooling Calculations associated with setting up a building to maintain proper minimum ventilation Choosing the correct equipment for proper ventilation Proper use of instruments to evaluate the pig s environment properly. Determining Ventilation Equipment Working Capacities Fans It is very important that you know the capacity of all the fans used to control the pigs environment. Fans are one of the most neglected pieces of equipment on the farm. Many employees pass by the fans everyday and never stop to evaluate their efficiency. Fan capacity outputs can be obtained from the manufacture or from independent lab data. An example of agricultural fan performances and efficiencies can be obtained from www.bess.uiuc.edu. Just remember, the results from the manufacture and independent labs resemble the performance of new fans. These results may be different from a ten year old fan in poor repair. In order to determine the efficiency of older existing fans, you must have the proper tools and formulas to calculate the fans efficiency or lack of. One of the first evaluations is a visual check of the fan. Ask the following questions: 1. Are the fan louvers hanging down when the fans is in full

operation, or are the louvers projecting straight out? 2. Is the fan belt flopping up and down? 3. Is the fan belt sunk down into the pulley or riding out to the pulley approximately 1/8 of an inch? These observations will give the operator a quick daily fans performance evaluation. Once you have determined there is a problem, the following tools and calculations will be needed to further evaluate the performance of the fan. The tools need for the evaluation is simple, an anemometer and a photo-tach. These instruments are relatively inexpensive and can be obtained on line or from a local livestock equipment dealer. Calculation: The first calculation involves determining the CFM s of an existing fan. Review the example evaluation attached. FIGURE FAN CFM S Formula Square Feet of Fan Formula Quantity of Air Produced Area = Π Radius 2 Q = A x V Area = 3.14 x Radius Quantity = Area x Velocity Area = sq/in Q = Fan Size sq/ft x Velocity ft/min 144 Quantity of = Cubic ft/min A = Square Feet of Fan Space Fan Discharge *144 Cubic Inches = 1 Square Foot Example: Quantity of Air Example: Area of a 48 Fan Produced by 48 Fan A = ΠR 2 Q = A x V 3.14 x 24 2 in Q = 12.56 sq ft / 1,850 ft min 3.14 x 576 Q = 23,236 Cubic ft/min A = 1808.64 sq in A = 1808.64 144 A = 12.56 sq ft Calculation: Determine the fan speed (RPM s) of the fan. Do this by measuring the RPM s of a new or reconditioned fan and then compare the RPM s of older fans. This comparison will help you quickly determine if fans need new belts, louvers or guard repair. It is very easy to have a 20% reduction in fan efficiency when the fan belt is worn or the louver and fan blades are dusty. Note; be sure to buy a good photo-tach that will detect the movement of all types of blades. Points to remember: 1. Most direct drive fan motors (blades attached to the motor) turn 1725 RPM s. 2. Belt drive fans have a fan deduction drive. Example: A 3 inch pulley on the motor and a 10 inch pulley on the fan shaft. This combination of pulleys results in the fan blades turning 517 RPM s instead of 1725. You must know the fan reduction before you can determine if the fan is operating a full capacity.

Example: Note; a 10 inch pulley on the fan shaft. Note; a 3 inch pulley on the motor. Math : 10 divided by 3 equals 3.33 to 1 ratio. Divide 1725 (motor speed) by 3. 33 equals 517 fan shaft RPM s. See attached picture: Inlets Inlets and fans must be sized together in order to deliver the correct amount of air at the correct speed and static pressure. Many people take the following approach to inlet size, That s about the right amount of inlet space. This approach is detrimental to pig health, especially during the winter months, correct inlet adjustment is essential to reduce drafts and save energy. The infrared picture below shows the inlet flow of air moving across the ceiling and warming up before falling on the pig. This inlet is sized properly with the fan output. Calculation: The calculations below represent one method of calculating proper air flow through an inlet. The example below will walk you through proper building setup and maintaining static CALCULATING AIR INLET OPENING FOR PROPER STATIC PRESSURE In a negative static pressure ventilated building the air inlet slot must be adjusted according to the CFM of air exiting the exhaust fans. The ideal static pressure to provide proper air is dependent on the width of the building and the placement of inlets. The measurements can

be measured by either a photohelic or manometer. The following table is a guide of how far to open your air inlet baffles in order to achieve the proper static pressure. Static Pressure Velocity thru Slot Amount of Opening per 1000 CFM.02 500 fpm 288 sq. in..03 600 fpm 240 sq. in..04 700 fpm 205 sq. in..05 800 fpm 180 sq. in..06 900 fpm 160 sq. in. Example: Nursery Pigs The has 600 pigs based on.09 cfm/lb @ 50 each = 2700 cfm 2700 cfm 800 fpm = 3.375 sq. ft x 144 = 486 sq. in. Assume: (4 Baffles 4 ft long) = 192 lineal inches 486 sq. in. by 192 lineal inches = 2.53 openings Problem #1: Minimum Ventilation Requirement 720 head finisher 40 x 160 Place Pigs 50 lb Exit pigs 240 lb Static Pressure.05 Inlets 10 4 sided ceiling diffusers inlets ( Factory stats: 2000 cfm s per diffuser. 48 fan minimum 48 fan stage 3 36 fan stage 2 48 fan stage 4 Questions: 1. What is the minimum ventilation requirement at pig placement (50 lb)? CFM 2. If all ceiling diffusers are open, what percentage of capacity are the units at placement under minimum ventilation requirements? % 3. What is the minimum ventilation requirement for the pigs at 240 lbs (No Death Loss)? CFM 4. What is the percentage of the capacity of the ceilings diffusers being used at 240 lbs? % 5. With all the fans running at full capacity how many CFM s of air will be moved through the house? CFM s Total

6. How many minutes/seconds should the minimum fan (48 ) run at placement? min/sec Problem #2: Minimum curtain opening for 720 head finisher 40 x 160 Curtain regulates static pressure No ceiling diffusers Fans on north wall Adjustable curtain on south wall Questions: How much should the curtain be open at pig placement? (50 lb pig) in. Is it possible to maintain? How far will the air travel across the ceiling before it drops on the pigs? Points to Remember: In a mechanically ventilated building, the air flow must come into the building at a sufficient velocity so the cooler air current can cling to the ceiling and warm up before it falls on the pigs. A proper static must be maintained to meet minimum air flow requirements. If the inlet is sized correctly, the pigs will not feel a cold air draft. Inlets must be adjusted and maintained to deliver the proper air flow. EVAPORATIVE COOLING Evaporative cooling has the capacity to reduce the temperature of a barn by 15 degrees, if it is maintained properly. A neglected cool cell is very ineffective, as This infrared photograph depicts a poorly maintained cool cell pad. Most of the distribution holes are not working. Only one small area of water is flowing through the pad (Note: 71.6 degrees in the cool section compared to 82 degrees where no water is flowing.) Poor water distribution across the pad surface reduces the effectiveness of the pad. The following list of potential problem should be addressed on a regular basis to improve cooling efficiency. Potential Cooling Problems: 1. Algae growth on the pad 2. Mineral deposits 3. Dirt accumulation on pad surface 4. Clogged discharged holes 5. Clogged filters There are solutions to each of these problems. These problems have been discussed at previous Healthy Hog Seminars. Research the files for solutions http://mark.asci.ncsu.edu/healthyhogs/default.htm.

Calculation: Using a sensitive digital thermometer compare the difference between the outside and inside temperature. Determine the percentage difference in the two reading. This simple test will help determine pad efficiency. Another important calculation is to determine the potential to cool the building by determining the difference between the dry bulb and wet bulb temperature using a psychrometer. If the air is dry the potential to cool is increased. As the difference between the wet bulb and dry bulb increase, the potential to cool is increased significantly. The chart below shows the cooling potential of a cool cell pad. Effective Temperature with Pad Cooling (AeroTech Inc.) Finishing Windchill Effect Based on Building 40' wide x 7'6" ceiling Pig Weight = 48 lbs. With Pad Evaporative Cooling Number or Fans Actual Tunnel Vel. Wind Chill Effective Temp. Temperature 48'' 36'' C.F.M. FPM Deg F. Deg F. 70 Time 2534.4 0 70 74 1 23000 30 2 72 78 1 1 34000 106 6 72 81 1 2 45000 141 8 73 84 2 2 68000 213 13 71 87 3 2 91000 284 17 70 Building Setup For Proper Minimum Ventilation Building setup is essential to maintain the proper ventilation for pigs a placement. Each group of pigs have their own ventilation requirements due to the size of the pigs, type of inlets, and the CFM s of the minimum ventilation fans. Other unique building characteristic play an important role in maintaining proper minimum ventilation. These include the age of the building, curtain condition and overall equipment condition. Stress management is the key to efficient pig production. The building should be maintained in the best possible condition. A well maintained facility allows the management to properly setup the house for individual groups of pigs. The formulas below are a guide to proper minimum ventilation setup.

FORMULA FOR MINIMUM VENTILATION REQUIREMENTS ON WEANED PIGS TO MARKET PIGS Formula: (#) of Pigs X lbs. each = 100 = X 9 = TOTAL CFM S Formula: (#) of Pigs X lbs. each pig x CFM needed per lab body wt. (.06/.09) = TOTAL CFM REQUIRED Timer Setting: (5 min. 300 sec/10 min 600 sec) Total CFM Required CFM of Time Fan X Timer (sec) = Seconds Run Time Example: 720 X 50 X.09 = 3240 3240 10,000 x 300 = 97 sec or 1.61 min CAUTION: AS PIGS GROW THEIR VENTILATION REQUIREMENTS CHANGE. THE MINIMUM VENTILATION SHOULD BE REFIGURED EACH WEEK AND CHANGED TO MATCH THEIR AVERAGE WEIGHT. THIS WILL INSURE THAT EACH PIG IS PROPERLY VENTILATED WHERE BY ALLOWING IT TO GROW NORMALLY AND HAVE GOOD HEALTH. Choosing the Correct Equipment for Proper Ventilation Fans are not created equal. The following lab exercise will help you determine which fan to purchase that will give you the most CFM s for your dollar (CFM/Watt). Fan replacement should not be taken lightly in today s economy. An efficient fan is worth the extra initial cost in long term electrical savings. Attached below is a worksheet and an example problem. Insert your figures and compare the cost of operation. Note; in the example problem, the better performing fan saved the owner $717 dollars in one year on energy cost. Determine Which Fan to Purchase Fan CFM s Per Watt Required Information: Formula Rate of Electricity ($ KWH) (Existing Power Rate) CFM s required in Building (Minimum or Total)

Average Hours per year of Operation (There are 8,760 hrs. in a year; Average Fan Operation 2,920 hrs.) CFM per Watt of Fans vs (Chose Two Fans From Bess Labs Fan Data or use existing fan information) Formula: Operation Required CFM (Elect. Rate) x (1000) x (Hrs. Year) ------------------------------------------- = Annual Cost of CFM Watt Example: 1 ( ) x (1000) x ( ) ------------------------------------------ = $ ( ) Example: 2 ( ) x (1000) x ( ) ------------------------------------------ = $ ( ) Savings: = $ (per year) Determine Which Fan to Purchase Fan CFM s Per Watt Required Information: Example Rate of Electricity ($ KWH).08 (Existing Power Rate) Total CFM s required in Building 180,000 (Minimum or Total) Average Hours per year of Operation 2920 (There are 8,760 hrs. in a year; 1.3 of 8760 = 2920 CFM per Watt of Fans 22 vs 16

Ex. 2 Ex.1 Formula: Operation CFM (Elect. Rate) x (1000) x (Hrs. Year) ------------------------------------------- = Annual Cost of CFM Watt Example: 1 180,000 (.08 ) x (1000) x ( 2920 ) ------------------------------------------ = $ 2,628 ( 16 ) Example: 2 180,000 (.08 ) x (1000) x ( 2920 ) ------------------------------------------ = $ 1,911 ( 22 ) Savings: = $ 717 (per year) Proper Use of Tools and Instrument to Help Evaluate the Pigs Environment This section of the lab will discuss the proper use of tools to evaluate the pigs environment. All of the information discussed earlier has very little benefit to the producer if the tools are not available to evaluate the situation. There are slight to extreme barn differences. Someone or a group of individuals need the tools and expertise to evaluate individual situations. Proper instrument utilization will be discussed in the lab setting. Listed below is a list of essential ventilation instruments. 1. Digital Thermometer Pen 2. Humidity Sensor Pen (High degree of accuracy) 3. Photo-tach 4. Digital temperature gun 5. Hand held photohelic 6. Anemometer (Air speed measuring device) Take Home Message 1. Be prepared to evaluate all ventilation situations. 2. Do not guess at the proper ventilation settings 3. Know your equipment 4. Have the tools necessary to get the job done

5. Train employees on proper ventilation techniques