CMD420 / CMD421 Series

Similar documents
GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Operating Manual RCM420

Operating Manual VMD420

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Insulation fault evaluator EDS460-DG

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

Manual CME420. Multi-functional current relay, AC, overcurrent/undercurrent/ window discriminator function CME420_D00034_02_M_XXEN/05.

1.7. Insulation fault evaluators EDS460/490 EDS461/491

T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE /

VME421H Voltage and frequency monitor

1.7. Insulation fault evaluators EDS460/490 EDS461/491

VME420 Voltage and frequency monitor

Bender GmbH & Co. KG. All rights reserved. Reprinting only with permission of the publisher. Subject to change! Photos: Bender archives

RCMA423. Residual current monitor for monitoring AC-, DC- and pulsed DC currents in TN- and TT systems Software-Version: D330 V1.0x.

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

RCMA423-DM1C Residual current monitor

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

LINETRAXX RCMS460-D/-L RCMS490-D/-L

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Remote alarm indicator and test combination MK2430

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Process Alarm Module RTA 421

MK Series. Remote Indicators For Line Isolation Monitors and Fault Location. Technical Bulletin NAE /

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

T M. User Manual LIM2010. Line Isolation Monitor

Multi-Gas-Controller MGC2

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Combustible Gas Detection and Control System

Line Isolation Monitor (LIM) LIM2000plus

Two-Channel Gas Controller

Monitoring Devices 11/1

Ordering Key. Dielectric strength

Digital Heater Element Burnout Detector K8AC-H

LINETRAXX RCMS150. Residual current monitor type B with integrated measuring current transformers for earthed AC/DC systems (TN and TT systems)

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

TC515 and TC600 Installation Manual. a Winters company

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Speed and Frequency Seite 1 von 7

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

DTA. Motor thermistor relay. Benefits. Description

Instruction Manual December 2001 ENACOCU02

Soft Starter Centrifugal Pump Soft Starter Series

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

SCHMIDT LED Measured Value Display MD Instructions for Use

Instruction Manual August sitrans CU 02

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Parameterisable compact fault annunciator with permanent display

DOCUMENTATION IPS640

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

DOCUMENTATION IPS640

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

TM800. Remote alarm indicator and operator panels

M15051) INSTRUCTION MANUAL

CU-02 with Senaco Plus

REA 105 Arc Protection Module. Operator s Manual

DKG-108 POWER FACTOR CONTROLLER

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Operating Manual UV Monitor UVT 18

Isolated Power Systems Equipment

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Operating Manual MSF220V(VU)

Table of Contents. Protective Relays

Operating Manual TR600

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Plug-in Base, Long Range Sensor E3B2

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Danfoss gas detection Controller unit

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

ST Wiring diagram. Product description. Standard temperature controller. Order number

Series Temperature Controller Instruction Sheet

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Transcription:

3 T M CMD420 / CMD421 Series Digital Current Relay (Overcurrent and Undercurrent) For Three-Phase AC Systems Technical Bulletin NAE1032810 / 06.2016

CMD420 / CMD421 Digital overcurrent and undercurrent relay for three-phase AC systems CMD421 Features Undercurrent and/or overcurrent monitoring in three-phase AC systems Current transformer ratio entered into device; primary values displayed in realtime on LCD display Overcurrent mode: 2 separate alarms Undercurrent mode: 2 separate alarms Window mode: High and low alarms Start-up delay, response delay, delay on release Adjustable switching hysteresis True RMS value measurement (AC) Digital LCD display with real-time readings and onboard menu LEDs: Power On, Alarm 1, Alarm 2 Memory stores last alarm value Non-volatile memory for settings Continuous self monitoring Internal test/rest button Two separate SPDT alarm relays Normally energized or normally de-energized operation Latching or non-latching operation Password protection for device setting Sealable transparent cover RoHS compliant Description CMD420 and CMD421 series relays monitor for overcurrent and/or undercurrent in threephase AC systems. Current is measured as true RMS values. Values are shown in real-time on the device's LCD display. The current on each phase may be displayed independently by pressing the UP or DOWN buttons on the device. Each alarm type may be independently activated or deactivated based on the system requirements. Three separate time delays (startup delay, alarm response delay, and delay on release) allow the CMD420 / CMD421 to be tailored to specific applications. Two SPDT alarm contacts may be assigned individual alarms. Measurements are obtained via connected current transformers, one per phase. The CMD420/CMD421 may be set to alarm from 0 to 1 A and uses current transformers with a 1 A secondary (x/1 type, up to 2000:1). The CMD421 may be set to alarm from 0 to 5 A and uses current transformers with a 5 A secondary (x/5 type, up to 2000:5). Transformer ratios should be selected based on the load current monitored. Alarm values are entered into the device based on the secondary rating of the current transformer. The ratio of the current transformers used is entered into the device's onboard menu. Doing so displays the current on the primary side of the current transformer during real-time operation - no mental calculations required. CMD420 and CMD421 devices utilize an external supply voltage for power. Consult table "Ordering Information" on available supply voltage ranges. Typical applications Three-phase AC systems Three-phase motors, pumps, and other industrial equipment General three-phase distribution networks / equipment requiring current monitoring Function Once the supply voltage is applied, the startup delay "t" is activated. Measured current that may cause an alarm will not activate until after the startup delay is complete. Each type of alarm may be assigned an individual value. Two separate alarm states ("R1" and "R2") may then be assigned any combination of these alarms to trip their respective contacts. When any alarm has been activated, the response delay t on1/2 will activate. Once the response delay has elapsed, if the alarm is still active, the appropriate contact will trip and the alarm LEDs light. Once the alarm has cleared, the delay on release t off begins. Once this delay has elapsed and the alarm is still cleared, the appropriate contact will switch back. If the device is set to operate in latching mode ("fault memory"), the device must be manually reset if it goes into alarm. If it is set to non-latching mode, the alarm will automatically clear itself. Regardless of this setting, the last alarm value will be stored in the device's onboard history. Device settings are stored in non-volatile memory and will remain set even with a loss of supply voltage. Approvals CMD420 0-1 A alarm setpoint (at ratio n = 1) Utilizes three separate 1 A secondary current transformers (x/1 type, up to 2000:1) CMD421 0-5 A alarm setpoint (at ratio n = 1) Utilizes three separate 5 A secondary current transformers (x/5 type, up to 2000:5) 2

Front display Wiring diagram 1 2 3 L3 L2 k3 l3 1 4 k2 l2 k1 l1 k3 l3 A1 A2 k1 l1 k2 U S 5 6 7 1 - Power On LED ON (green), lights when supply voltage is applied and flashes in the event of system fault alarm. 2 - Alarm LED AL1 (yellow): lights when the set response value is exceeded and flashes in the event of system fault alarm. 3 - Alarm LED AL2 (yellow): lights when the value falls below the set response value and flashes in the event of system fault alarm. 4 - Multi-functional LCD display 5 - Test button T : UP key: Change displayed value, move downwards in the menu or change parameters. Holding for > 1.5 s initiates a self-test. 6 - Reset R button: DOWN key: Change displayed value, move downwards in the menu or change parameters. Holding for > 1.5s resets the device. 7 - MENU key: Enter key: Confirms / changes parameters. When on the main screen, holding for > 1.5 s enters the main menu. When in the menu, holding for > 1.5 s cancels an action or moves back a step in the menu structure. 5 2 A1 A2 11 12 K1 14 3 K2 l2 21 22 24 4 1 - Connection to individual conductors via current transformers 2 - Supply voltage U S (see ordering information) 3 - Alarm relay K1: Configurable for all available alarms 4 - Alarm relay K2: Configurable for all available alarms 5-5 A supply voltage fusing required 3

Ordering information Type Supply voltage U S* Response value Supported CT type Ordering No. CMD420-D-1 DC 9.6 94 V / AC 42 460 Hz 16 72 V 0 1 A 1 A secondary (x/1) up to 2000:1 B 9306 0006 CMD420-D-2 DC 70 300 V / AC 42 460 Hz 70 300 V 0 1 A 1 A secondary (x/1) up to 2000:1 B 9306 0007 CMD421-D-1 DC 9.6 94 V / AC 42 460 Hz 16 72 V 0 5 A 5 A secondary (x/5) up to 2000:5 B 9306 0008 CMD421-D-2 DC 70 300 V / AC 42 460 Hz 70 300 V 0 5 A 5 A secondary (x/5) up to 2000:5 B 9306 0009 * absolute values Dimensions Dimensions in inches (mm) Open the front plate cover in direction of arrow. 2.78 (70.5) 1.87 (47.5) 1.42 (36) 1.22 (31.1) Screw fixing Note: Additional clip required for screw mounting (See ordering information). Accessories Type Ord. No. Clip for screw mounting (Qty. 1 req'd) B 9806 0008 2.66 (67.5) 1.77 (45) 3.54 (90) 3.94 4.57 4 Technical data Insulation coordination acc. to IEC 60664-1 / IEC 60664-3 Rated insulation voltage AC 250 V Rated impulse voltage/pollution degree 6 kv / III Protective separation (reinforced insulation) between (A1, A2) - (k, l) - (11, 12, 14) - (21, 22, 24) (k1, l1, k2, l2, k3, l3) - (11, 12, 14) Maximum rated voltage of the system being monitored (conductor to be monitored directly connected) With protective separation AC 230 V Without protective separation AC 400 V Voltage test according to IEC 61010-1 2.21 kv Supply voltage CMD420-D-1, CMD421-D-1: Rated supply voltage U S Rated supply frequency U S CMD420-D-2, CMD421-D-2: Rated supply voltage U S Rated supply frequency U S Power consumption Measuring circuit, CMD420 Effective measuring range, n=1 Overload capacity, continuous Overload capacity < 5 s Burden AC 16 72 V / DC 9,6 94 V DC, 15 460 Hz AC/DC 70 300 V DC, 15 460 Hz 4 VA AC 0 1 A 2 A 5 A 50 mω Rated frequency f n 42 460 Hz Response values, CMD420 Undercurrent Lo < I (Alarm 2) n = 1 AC 0.1 1 A (0.3 A)* Undercurrent Lo < I (Alarm 1) n = 1 100 % 200 % (150 %)* Maximum of 1 A Overcurrent Hi > I (Alarm 2) n = 1 AC 0.1 1 A (0,3 A)* (Hi)* Overcurrent Hi > I (Alarm 1) n = 1 50 % 100 % (50 %)* (Hi)* Window I n > I (Alarm 2) n = 1 AC 0.1 1 A (0,3 A)* Window I n < I (Alarm 1) n = 1 50 % 100 % (50 %)* External current transformer ratio x/1 A (1 A secondary) Transformer ratio setting factor n 1 2000 (1)* Relative percentage error at 42 460 Hz ± 5 %, ± 2 digit Hysteresis 3 40 % (15 %)* Measuring circuit, CMD421 Effective measuring range, n=1 Overload capacity, continuous Overload capacity < 5 s Burden Rated frequency fn AC 0 5 A 7.5 A Screw terminal versions: 20 A Cage clamp versions: 12 A 3 mω 42 460 Hz Response values, CMD421 Undercurrent Lo < I (Alarm 2) n = 1 AC 0.5 5 A (1,5 A)* Undercurrent Lo < I (Alarm 1) n = 1 100 % 200 % (150 %)* Maximum of 5 A

Technical data (continued from previous page) Overcurrent Hi > I (Alarm 2) n = 1 AC 0,5 5 A (1,5 A)* (Hi)* Overcurrent Hi > I (Alarm 1) n = 1 50 % 100 % (50 %)* (Hi)* Window I n > I (Alarm 2) n = 1 AC 0.5 5 A (1,5 A)* Window I n < I (Alarm 1) n = 1 50 % 100 % (50 %)* External current transformer ratio x/5 A (5 A secondary) Transformer ratio setting factor n 1 2000 (1)* Relative percentage error at 42 460 Hz ± 5 %, ± 2 digit Hysteresis 3 40 % (15 %)* Specified times Start-up delay t Response delay t on1 Response delay t on2 Delay on release t off Time delay increment: t, t on1/2, toff (0 10 s range) Time delay increment: t, t on1/2, toff (10 99 s range) Time delay increment: t, t on1/2, toff (100 300 s range) Operating time t ae Response time t an Operating release time tre Release time t aus Recovery time tb Displays, memory Display type Display range measured value (x n) Display error at 42 460 Hz Measured value (HiS) for last alarm Password Latching capability 0 300 s (0.5 s)* 0 300 s (1 s)* 0 300 s (0 s)* 0 300 s (0.1 s)* 0.1 s 1 s 10 s 130 ms tan = tae + ton1/2 130 ms taus = tre + toff 300 ms LCD display,multifunctional CMD420: AC 0 1 A x n CMD421: AC 0 5 A x n ± 5 % ± 2 digit Last recorded alarm off / 0 999 (off)* on / off / con (on)* Switching elements Number of changeover contacts 2 SPDT relays Operating principle Normally energized or normally de-energized Electrical service life 10.000 switching operations Contact data acc. to IEC 60947-5-1 Utilization category AC-13 AC-14 DC-12 DC-12 DC-12 Rated operational voltage 230 V 230 V 24 V 110 V 220 V Rated operational current 5 A 3 A 1 A 0.2 A 0.1 A Minimum contact load / gold-plated relay contacts 1 ma at AC/DC 10 V Environment / EMC EMC IEC 61326-1 Operating temperature -13 ºF +131 ºF (-25 ºC +55 ºC) Climatic class acc. to IEC 60721 Stationary use (IEC 60721-3-3) 3K5 (except condensation and formation of ice) Transport (IEC 60721-3-2) 2K3 (except condensation and formation of ice) Long-time storage (IEC 60721-3-1) 1K4 (except condensation and formation of ice) Classification of mechanical conditions IEC 60721 Stationary use (IEC 60721-3-3) 3M4 Transport (IEC 60721-3-2) 2M2 Long-time storage (IEC 60721-3-1) 1M3 Connection Connection Connection properties: rigid push-wire terminals 0.2 2.5 mm² ( AWG 24 14) Flexible without ferrules 0.2 2.5 mm² ( AWG 24 14) Flexible with ferrules 0.2 1.5 mm² ( AWG 24 16) Stripping length 10 mm Opening force 50 N Test opening, diameter 2.1 mm Other Operating mode continuous operation Position of normal use any Degree of protection, internal components (IEC 60529) IP30 (NEMA 1) Degree of protection, terminals (IEC 60529) IP20 (NEMA 1) Enclosure material polycarbonate Flammability class UL94V-0 DIN rail mounting acc. to IEC 60715 Screw mounting 2 x M4 with mounting clip Product standard IEC 61010-1 and according to IEC 60255-6 Firmware version, CMD420 D287 V1.1x Firmware version, CMD421 D294 V1.1x Weight 160 g ( )* factory setting 5

USA, Mexico, and Central America Exton, PA 800-356-4266 / 610-383-9200 info@bender.org www.bender.org T M Your local contact: Document NAE1032810 / 06.2016 / Bender Inc. Canada Mississauga, ON 800-243-2438 / 905-602-9990 info@bender-ca.com www.bender-ca.com South America Santiago de Chile +56 2 2933 4211 info@bender-latinamerica.com www.bender-latinamerica.com