ESAC ebacgw Tecnoalarm

Similar documents
ESAC ebacgw Siemens. Date: Oct 15,2008. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

ESAC ebacgw Meteo. Date: Nov 25,2008. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

Delta ORCAview 3.40 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

Enterprise Buildings Integrator R500 Protocol Implementation

Document Introduction Annex A - Protocol Implementation Conformance Statement (Normative) Product Description... 4

C5 controller Bacnet

MRMS Multi-Room Monitoring Station

CS-RS. Remote Sensor User Manual

DESCRIPTION OF CONTROL

EBI R410 BACnet Direct Protocol Implementation Conformance Statement (PICS)

B. This Section includes DDC controls for Lighting system installed on the same operator interface as the HVAC controls.

IMC BACnet Module. Service Literature. Table of Contents. General. Field Connections. Physical

TC Compact Series. Features. Description. Technical Specification Sheet Document No December 2, 2009

PXC Modular Series for BACnet Networks

FS20 / FS720 BACnet Protocol Implementation Conformance Statement (PICS) System Description

Compact Series Unitary Equipment Controller

IAQPoint MONITEUR DE QUALITÉ DE L AIR INTÉRIEUR INDOOR AIR QUALITY MONITOR. Manuel d utilisateur User Manual

Houston Independent School District Design Guidelines Version 3.0 Revised August 2015 SECTION DIRECT DIGITAL CONTROLS

PIR Ready VT76xx Series Programmable & Non-Programmable Thermostats For Commercial HVAC Applications. BACnet Integration Manual September 1, 2010

Daikin Loop Water Manager Protocol Information

Fan Coil Controller. EFCB Series BACnet Communication Module User Guide. EFCB-BACnet Guide-EUA

BACnet Integration Manual ITG-VH72xx-BAC-E00 ( _R0 Issue Date: October 21, 2008)

Design Standards Brief Section 9 Building Automation System and Automatic Controls

IntesisBox BACnet/IP Server - Notifier ID3000 series

SECTION INTEGRATED AUTOMATION FACILITY CONTROLS

Manual for the integration in BMS/GTC

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Table of Contents. i-vu CCN Standard 4.2

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

UNC100 Integra Manual

ONYXWORKS AND FIRSTVISION. Version 4

Multistate Alarm. Introduction

OJD ITB No Attachment E Duress Alarm Equipment Specifications

Integrated Security Solutions

Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway

MEPF SPECIFICATIONS SECTION ELECTRICAL GENERAL PROVISIONS SECTION BASIC MATERIALS AND METHODS. MFE MEPF Specification Index Index - 1

fmap Log / Troubleshooting Manual Release 8.0 Issue 1

SEQUENCE OF OPERATIONS

F Technical Bulletin SC 370 SMART Modbus Interface

MicroTech III Applied Air Handling Unit Controller Protocol Information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

FieldServer Driver - Serial FS SBT-FSI (Siemens Building Technologies Foreign Systems Interface)

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Building Management System

Added password for IP setup page : Password must be in IP format!

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm.

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

SECTION INSTRUMENTATION AND CONTROLS FOR HVAC

FS Mircom FX2000 Fire Alarm Panel

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Lift Station Level Controller

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

RESPONSES TO BIDDERS QUESTIONS:

CATALOG NUMBER. Features. Description

Integrated Security Solutions

CONSTRUCTION SYSTEMS AND ASSEMBLIES

FlameGard 5 UV/IR HART

The EN54 Part 2, 4 and 13 Fire System

Introduction. Introduction

INSTRUCTION MANUAL. stay ahead - stay informed 1. THE APP

V10 Controller - BACnet lnterface Supplement 1

Ref.1067/032 Ref.1067/042

1. Introduction. 2. Product overview

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

B. After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator.

Flexibility. adjusted to specific needs of a client.

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Manage Alert Rules & Teams

D-Link Central Management System

Release Notes for Version 7.05 January 2007

MicroTech III Rooftop and Self Contained Unit Controller Protocol Information

Niagara4 Technical Certification Program Student Guide DAY 1 DAY 2

ARCHITECTURAL AND ENGINEERING SPECIFICATION

Ademco Vista Alarm Panel

I/O ZONE 560/583 USERS GUIDE

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

opti-visor ultra-efficient chiller plant automation Typical specification

UD-VMS510i. Surveillance Management Center

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

abode Web app Functionality

Document # R01

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

Security designed for your lifestyle

Carbon Monoxide Transmitter

Fire Alarm Network Reference

/14 Rev. A LYNX Touch L5210 Series

Ness acomms Install & User Manual

MiNi Server environment MoNitoriNg SySteM

GMS GRAPHICAL MANAGEMENT SYSTEM

Alarm module for leak detection with webserver

Scotch Plains, New Jersey SECTION DIRECT DIGITAL CONTROL (DDC) SYSTEM FOR HVAC

2000 Series. Program Entry Guide. Control Panels

T4000 Security Communicator

CONTROL OF HVAC

IndigoVision Alarm Panel. User Guide

Transcription:

Date: Feb 28,2011 Vendor Name: ESAC srl Product Name: ebacgw-tecnoalarm Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3 Product Description: ebacgw is a BACnet gateway for Tecnoalarm intrusion detection system; based on a high reliability 32 bit architecture,automatic configuration detection allows the device to operate with minimal user effort for configuration. The following items can be controlled via BACnet: Anti intrusion plant Statuses standby failure low battery mains failure maintenance Alarms tampering false key/code panic rapine technical room jamming Zone command: enable/disable status: disabled/active/inactive/open/closed Program command: on/off/zoned/unzoned status: idle, exit, armed, zoned, alarm BACnet Standardized Device Profile (Annex L): BACnet Operator Workstation (B-OWS) BACnet Building Controller (B-BC) (except DM-DOB-A) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Sensor (B-SS) BACnet Smart Actuator (B-SA) Gen,10 2010 (rev 1.0) SUBJECT TO CHANGE page 1 of 6

s Supported (Annex K): Data Sharing Data Sharing-ReadProperty-A (DS-RP-A) Data Sharing-ReadProperty-B (DS-RP-B) Data Sharing-ReadPropertyMultiple-A (DS-RPM-A) Data Sharing-ReadPropertyMultiple-B (DS-RPM-B) Data Sharing-ReadPropertyConditional-A (DS-RPC-A) Data Sharing-ReadPropertyConditional-B (DS-RPC-B) Data Sharing-WriteProperty-A (DS-WP-A) Data Sharing-WriteProperty-B (DS-WP-B) Data Sharing-WritePropertyMultiple-A (DS-WPM-A) Data Sharing-WritePropertyMultiple-B (DS-WPM-B) Data Sharing-COV-A (DS-COV-A) Data Sharing-COV-B (DS-COV-B) Data Sharing-COVP-A (DS-COVP-A) Data Sharing-COVP-B (DS-COVP-B) Data Sharing-COV-Unsolicited-A (DS-COVU-A) Data Sharing-COV-Unsolicited-B (DS-COVU-B) Scheduling Scheduling-A (SCHED-A) Scheduling-Internal-B (SCHED-I-B) Scheduling-External-A (SCHED-E-B) Trending Trending-Viewing and Modifying Trends-A (T-VMT-A) Trending-Viewing and Modifying Trends-Internal-B (T-VMT-I-B) Trending-Viewing and Modifying Trends-External-B (T-VMT-E-B) Trending-Automated Trend Retrieval-A (T-ATR-A) Trending-Automated Trend Retrieval-B (T-ATR-B) Network Management Network Management-Connection Establishment-A (NM-CE-A) Network Management-Connection Establishment-B (NM-CE-B) Network Management-Router Configuration-A (NM-RC-A) Supported Gen,10 2010 (rev 1.0) SUBJECT TO CHANGE page 2 of 6

Network Management-Router Configuration-B (NM-RC-B) Alarm and Event Management Alarm and Event-Notification-A (AE-N-A) Alarm and Event-Notification Internal-B (AE-N-I-B) Alarm and Event-Notification External-A (AE-N-E-B) Alarm and Event-ACK-A (AE-ACK-A) Alarm and Event-ACK-B (AE-ACK-B) Alarm and Event-Alarm Summary-A (AE-ASUM-A) Alarm and Event-Alarm Summary-B (AE-ASUM-B) Alarm and Event-Enrollment Summary-A (AE-ESUM-A) Alarm and Event-Enrollment Summary-B (AE-ESUM-B) Alarm and Event-Information-A (AE-INFO-A) Alarm and Event-Information-B (AE-INFO-B) Alarm and Event-LifeSafety-A (AE-LS-A) Alarm and Event-LifeSafety-B (AE-LS-B) Device Management Device Management-Dynamic Device Binding-A (DM-DDB-A) Device Management-Dynamic Device Binding-B (DM-DDB-B) Device Management-Dynamic Object Binding-A (DM-DOB-A) Device Management-Dynamic Object Binding-B (DM-DOB-B) Device Management-DeviceCommunicationControl-A (DM-DCC-A) Device Management-DeviceCommunicationControl-B (DM-DCC-B) Device Management-Private Transfer-A (DM-PT-A) Device Management-Private Transfer-B (DM-PT-B) Device Management-Text Message-A (DM-TM-A) Device Management-Text Message-B (DM-TM-B) Device Management-TimeSynchronization-A (DM-TS-A) Device Management-TimeSynchronization-B (DM-TS-B) Device Management-UTCTimeSynchronization-A (DM-UTC-A) Device Management-UTCTimeSynchronization-B (DM-UTC-B) Device Management-ReinitializeDevice-A (DM-RD-A) Device Management-ReinitializeDevice-B (DM-RD-B) Supported Gen,10 2010 (rev 1.0) SUBJECT TO CHANGE page 3 of 6

Device Management-Backup and Restore-A (DM-BR-A) Device Management-Backup and Restore-B (DM-BR-B) Device Management-List Manipulation-A (DM-LM-A) Device Management-List Manipulation-B (DM-LM-B) Device Management-Object Creation and Deletion-A (DM-OCD-A) Device Management-Object Creation and Deletion-B (DM-OCD-B) Device Management-Virtual Terminal-A (DM-VT-A) Device Management-Virtual Terminal-B (DM-VT-B) Supported Segmentation Capability: Segmented Requests Supported Window Size: - Segmented Responses Supported Window Size: 1 Standard Object Types Supported: Object-Type Supported Optional Properties Supported Writable Properties Analog Input Analog Output Analog Value Averaging Binary Input Binary Output Binary Value Description, Reliability Active Text, Inactive Text, Priority Array, Relinquish Default, Time Delay, Notification Class, Alarm Value, Event Enable, Notify Type Calendar Commad Device Description, Location, APDU Seg Timeout, Local Time, Local Date Status Object Name, Description, Present Value, Reliability, Active Text, Inactive Text, Pririty Array, Relinquish Default, Time Delay, Event Enable, Notify Type Object Name, Description, Location, Local Time, Local Date Event Enrollment Gen,10 2010 (rev 1.0) SUBJECT TO CHANGE page 4 of 6

File Group Life Safety Point Life Safety Zone Loop Multi-state Input Multi-state Output Multi-state Value Description,Reliability,State Text, Priority Array, Rlinquish Default, Time Delay, Notification Class, Alarm Values, Fault Values, Event Enable, Notify Type Object Name, Description, Reliability, State Text, Priority Array, Relinquish Default, Time Delay, alarm Values, Fault Values, Even Enable, Notify Type Notification Class Description Object Name Description Priority Recipient List Program Schedule Trend Log Data Link Layer Options: BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7) (10Base2, 10Base5, 10BaseT, Fiber) ANSI/ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ANSI/ATA 878.1, RS-485 ARCNET (Clause 8), baud rate(s): MS/TP master (Clause 9), baud rate(s): 9600, 19200, 38400, 76800 MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 10), baud rate(s): 9600, 19200, 38400 Point-To-Point, modem, (Clause 10), baud rate(s): 9600, 19200, 38400 LonTalk, (Clause 11), medium: Other: Intelli-Net (Coax) Device Address Binding: Is static device binding supported? Yes No (Necessary for two-way communication with MS/TP slaves and certain other devices.) Gen,10 2010 (rev 1.0) SUBJECT TO CHANGE page 5 of 6

Networking Options: Router Annex H, BACnet Tunnelling BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Character Sets Supported: Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ANSI X3.4 IBM/Microsoft DBCS JIS C 6226 ISO 10646 (ICS-4) ISO 10646 (UCS2) ISO 8859-1 If this product is a communication gateway, describe the types of non-bacnet equipment/networks(s) that the gateway supports: This gateway fully supports the Tecnoalarm TECNO-OUT (over TCP/IP) proprietary protocol Gen,10 2010 (rev 1.0) SUBJECT TO CHANGE page 6 of 6