New Features. IES Virtual Environment 6.4

Similar documents
ApacheHVAC in VE 2012

ApacheHVAC User Guide Part B: Equipment, Loops, Components, and Controls

ApacheHVAC User Guide. IES Virtual Environment 6.4

ApacheHVAC User Guide

TRACE 700. Slide 1. Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE.

Copyright 2017 Integrated Environmental Solutions Limited. All rights reserved.

Daikin VRV Systems Plugin VE2012 User Guide

INDOOR CLIMATE OF A SINGLE ZONE

Direct and indirect evaporative cooling

Daikin VRV Sizing & Simulation Plug-in User Guide

ApacheHVAC User Guide Part F: Loads Analysis and Reporting Tools

Plant Application Guide

Plant Application Guide

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

V4 15JUNE2016 (COPYRIGHT: DEPARTMENT OF INDUSTRY)

HVAC Water chiller selection and optimisation of operation

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Pack Calculation Pro. Users guide. Version Morten Juel Skovrup

Examples of Heat Pumps in DEAP

Hello, my name is Audra Benzschawel and I m a marketing engineer in the C.D.S. Slide 1 TRACE 700

Plate-and-frame free cooling

Modeling projects that require very tight space temperature control

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

End-Use Data Collection Requirements Data Trend Type

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

MECHANICAL SERVICES 101. Ian White

Managing Network Alarms and Events

- Data Brochure Universal Reset Module 422

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

- Data Brochure Universal Reset Module 423

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

GEOTHERMAL DESIGN GUIDE

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Summary Comparison of Simulation Program Features

i-vu CCN 4.0 Owner s Guide

AIR CONDITIONER PERFORMANCE RATING

A full list of energy conservation opportunities (ECO) for air-conditioned buildings

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

Monitor Alarms and Events

THERMAL ICE STORAGE: Application & Design Guide

Method to test HVAC equipment at part load conditions

Laptop / PC Programming Manual

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

Interior Design Tutorial

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

Improvement schedule for SAP May 2014 Note 8 revised 29 May 2014 NI high/further measures corrected 17 July 2014

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Milestone XProtect Alarm Matrix Integration 1.0

WeatherLink for Alarm Output Addendum

General HVAC Recommendations

Appendix 13. Categories of Cooling and Heating systems

Technical Criteria for District Energy Ready Buildings Master Requirement ENG 108 Building Department: ,

1 Air Handling Units In ICE

MU053: CHILLERS: Operation & Maintenance of Chilled Water Systems

Interior Design Tutorial

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

Installation & Operation Manual

DISTRIBUTION SYSTEMS. Water Piping and Pumps

August 15, 2013 Page 1 of 19

Best Practices for Condensing Boilers

Radiant Cooling Nonresidential HVAC Stakeholder Meeting #2

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

- Data Brochure Steam Control 279

Ion Gateway Cellular Gateway and Wireless Sensors

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

Fans and Pumps I. Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong

prestige Control Application Supplement - ACVMax

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A

ASHRAE JOURNAL ON REHEAT

Control Application. Supplement - ACVMax

THERMOSYS 4.3. Getting Started Guide

Zeroth Energy System. Presenter. Date

- Data Brochure D 260. Boiler Control /09

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

SOLAR COMBISYSTEMS IN DENMARK - THE MOST COMMON SYSTEM DESIGNS

Experion PKS Operator Course EXP01R201 06/2004 Rev 01

INFORMATION BOOKLET NRG Zone Models 2,3 and 4 Designed, Developed and Manufactured in Ireland

Smoke Layer Height and Heat Flow through a Door

PM-ANALYZE. Overview 1. System Configuration 2. Operation 3. Analysis of Alarms and process values. User Interface 4

Systems engineering Slide 1

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Interior Design Tutorial

Installation and Instructions for Use Outdoor Sensor

EnergyPlus Testing with Global Energy Balance Test

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

Mechanical Redesign, Proposal Elizabeth C. Krauss Mechanical Option September 18, 2013

COGEN SYSTEM S ICE MAKER(BARAF DEPOT) USING ENGINES JACKET & EXHAUST WASTE HEAT & AMMONIA WATER LIQUID ABSORPTION CHILLER

SECTION I: EXISITNG SYSTEM AND PROPOSED SYSTEMS

Hello, my name is Sarah Hilden and I am a Marketing Engineer in the C.D.S. group at Trane.

4 Wiring Brochure Wiring and

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB

Daikin Blueprint: Delivering Hot Water with a Chiller

Maincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?

TopGas Wall Hung Condensing Gas Boiler

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

Transcription:

New Features IES Virtual Environment

Contents New Features... 1 1 Tabular Room Data editing for thermal properties... 3 2 ApacheHVAC... 4 3 Alternate system schedules: enhancements... 17 4 BREEAM Navigator... 18 New Features 2

1 Tabular Room Data editing for thermal properties There is a new button in Apache, UK Part L2, and PRM Tabular Room Data. This tool represents a real productivity enhancement to model data entry and review. It contains many useful items: Rapid data input Rapid data review Copy / Paste (to/from excel) Filters only show the data of interest Fully customisable tab setup (add, remove columns, re-order etc) Multi-room edit/review Edit/Review variant model room data. Perhaps the key benefit of tabular edit is the productivity gains it will provide for large project review and data modification. Key features include rapid data input, rapid data review and crucially, a copy and paste facility allowing data to be pasted directly to and from excel. You can use left-click, right-click, multi-select (shift / ctrl) etc. to modify and access data. Other key features are the ability to apply filters, allowing users to view only the data of interest. When filters are on, the column heading to which the filter is applied will contain a blue bar. Hovering over this presents the user with a balloon tip summarising the current filter. New Features 3

2 ApacheHVAC There are a significant number of enhancements to the HVAC functionality. Prototype systems library Heat sources: Hot water loop, Generic heat source, inbuilt (non-networked) Heat pumps Solar water heater (on Hot water loop) Advanced heating coil Air-to-air heat pumps Chilled water loop: integrated Waterside economizer Chilled water loop: heat rejection by Fluid cooler Over-capacity Hot water & Chilled water loops Alternate system schedules: enhancements Prototype systems library Instead of loading all the predefined prototype systems at the same time, you now import them one at a time, by clicking the new Library button in the toolbar. (The S button is retained, but now only used to either select entire system(s) or edit their Descriptions). In the library interface, you can specify the import placement by selecting the relevant to-theright or below arrow buttons. New Features 4

Common pipe Absorption chiller DHW Radiator Simple coil Advanced coil Note that the 12 PRM-specific systems are distinguished, by both name and icon, from the general-purpose prototype systems. There is also a wider variety of systems available than in previous releases. In this release all the library systems share a common set of heating/cooling plant equipment (of which each system only uses part). Normally an import on top of another will *not* duplicate the plant, but there are options to override this for heating and/or cooling. This would only be used occasionally, in the specific case where some or all of your current network s plant has already been modified or sized, and you would like the coils in the imported system to be served instead by the original, unmodified, plant. Heat sources The Heat source list now lists two different types of Heat source, each with associated heating equipments: 1. Hot water loop: used to model heat sources involving hot water. Heating equipments are switched in according to a user-specified sequencing scheme, and sized on the basis of userspecified load percentages. 2. Generic heat source: used to model other types of heat source, such as electrical resistance, furnace, steam loop etc. In this case there is a single (Part load curve) heating equipment and hence no equipment sequencing. The associated heating equipment is of two types: 1. Hot water boilers (HWB): associated with Hot water loop only, in any number. 2. Part load curve heating plant (PLE): Hot water loop may have any number but a Generic heat source has one only. In addition to the above heating equipment, a Hot water loop may have a Solar water heater and/or an Air-to-water heat pump (AWHP). Please refer to the conceptual configuration below. CHR AWHP T lbt Key: water air CHP PLE 1 V b Secondary pump T ldb g l PLE 2 HWB 1 HWB 2 Primary pump T edb g e Heat sources Solar water heater Hot water loop New Features 5

In ApacheHVAC the Heat sources list now appears as below, with the different types of Heat sources, and attached heating equipments, all indicated by four different types of icon. The (single) Heat source designated to serve DHW loads, if any, is also indicated by red text. Hot water loop New Features 6

As shown by the dialog tabs above and below, many of the parameters that were previously defined within an individual Hot water boiler are now shared among all the boilers in a loop, and therefore are now defined at the Hot water loop level. Please refer to the ApacheHVAC manual for more details. Note that Heat pumps are no longer network objects. When upgrading an existing HVAC network to version.1, a (networked) heat pump whose backup is a Hot water boiler is upgraded to an Air-to-water heat pump attached to a Hot water loop (whose single Heating equipment is the old Hot water boiler). In the network the pump is replaced by a simple connector. New Features 7

The final Hot water loop tab (below) is conceptually similar to that for the existing Chilled water loop. It defines the Heating equipment set, and its sequencing and autosizing. Generic heat source The Generic heat source edit dialog is shown below. As already mentioned above (under Hot water loop), parameters such as Condenser heat recovery and CHP, that were previously defined within the Part load curve (Heating equipment), are now defined at the Heat source level. Like the Hot water loop, a Generic heat source may have a heat pump attached, but in this case it functions as an Air-source heat pump. When upgrading an existing HVAC network to version.1, a networked heat pump whose backup is a Part load curve heating plant is upgraded to either: New Features 8

an Air-to-air heat pump (new separate object, described below) whose backup is a Generic heat source (upgraded from the old Part load curve). or under certain circumstances (see ApacheHVAC manual for more details), an Air-to-source heat pump attached to a Generic heat source (upgraded from the old Part load curve). In both cases the pump (being no longer a network object) is replaced by a connector in the network. Solar water heater A solar water heater in a Hot water loop is defined in exactly the same way as in the Apache view: New Features 9

Advanced heating coil Paralleling the recently introduced Advanced Cooling coil modelling, there is now an Advanced heating coil model. This model makes the assumption that it is served by hot water, therefore only Hot water loops are available for selection as the serving Heat source. Unlike Advanced cooling coils, Advanced heating coils are autosized by Apache only; there is no manual sizing option. New Features 10

New Features 11

Air-to-air heat pump The Air-to-air heat pump (AAHP) is a new component type. Instances of this type are intended to serve Simple heating coils, in place of an ASHP. The Edit dialog for an AAHP is shown below. The Backup heat source is limited to Generic heat sources, but now many pumps can share the same backup. Furthermore the use of a backup is now optional. Another difference from the old ASHP is that the Output performance values are now expressed as percentages of the maximum value (bottom row). New Features 12

New Features 13

Chilled water loop: integrated Waterside economizer The new IWSE model enhances the current Waterside economizer modelling capability to provide for waterside economizer operation as a pre-cooling device in conjunction with a chiller set. The v.1 implementation of the IWSE shares the heat rejection condenser water loop and tower with an Electric Water Cooled chiller. New Features 14

Chilled water loop: heat rejection by Fluid cooler A fluid cooler is now available as an optional substitute for a cooling tower as the heat rejection device in a chilled water loop. There are two types, or modes of operation, of a fluid cooler. These depend on the wetting conditions of the surface of the coil in the stream of outside air. A dry fluid cooler is one where the coil is permanently dry. This type of cooler tends to be used in areas where there are restrictions on the availability of water. A wet/dry fluid cooler is one where the coil is sprayed with water to provide additional evaporative cooling. To prevent freezing of the water on the coil, these coolers can also operate as a dry fluid cooler. New Features 15

Over-capacity Hot water & Chilled water loop Improvement has been made to the modelling of undersized or overloaded heating and cooling sources. Previously, if equipment (heating coils, cooling coils, etc.) on a heating or cooling loop demands more heating or cooling than the source is designed to provide, the demand is always met the source performing above its design capacity. Now deficiencies in capacity at the heating and cooling sources hot water loops and chilled water loops will feed back to the air handling components they serve. In other words, the heating and cooling sources will always try to raise or reduce the return hot or chilled water temperature to the target supply water temperature. If the target supply water temperature cannot be reached, the return water temperature will be raised or reduced in response to the shortfall. The adjusted water supply temperature only affects certain types of component. Advanced heating and cooling coils respond to the adjusted supply temperature by reducing the amount of heating or cooling they are able to deliver. Other components, including simple heating and cooling coils, radiators and chilled ceilings, do not respond to the adjusted temperature. Their loads are dictated solely by conditions in the air-side system or the building. Likewise, any domestic hot water loads placed on a hot water loop, and loads placed on this loop by absorption chillers, are insensitive to the hot water loop supply temperature. Generic heat sources continue to follow the old policy: for these heat sources a shortage of capacity does not feed back to the components they serve. New Features 16

3 Alternate system schedules: enhancements The system schedules dialog has been modified to allow the user to create alternative profiles. This will allow the user to rapidly generate and edit multiple sets of alternative profiles. These newly created profiles can then be assigned to various scheduling scenarios for HVAC, setpoints etc. New Features 17

4 BREEAM Navigator A BREEAM Navigator has been created which makes assessing BREEAM 2008 credits much easier. It assists with the calculation of 42 credits and 6 innovation points, covering: Daylighting Indoor Air Quality Thermal Comfort LZCT Emissions and Free Cooling Water and Recycling Materials (Specification) Materials (Responsible Sourcing) Supported schemes are Offices, Schools, Higher Education, Healthcare and Retail: New Features 18

LZCT (ENE 1 and ENE 5 credits) The BREEAM calculator allows extensive configuration of Renewable, low carbon, and green power options (select the Choose LZCT option in the navigator). When selecting any LZCT technologies through this interface, please ensure they are not also defined as part of your Apache System or Apache renewables, else the double definition will cause incorrect simulation results. New Features 19

Emissions and free cooling (ENE 1 and ENE 10 credits) The credit calculation for Emissions (ENE1) credit requires the completion of an EPC Compliance simulation. This requires a CIBSE weather file. For those users who do not have a Compliance licence, a new interface is provided for basic Compliance configuration (Simulation settings): For free cooling (ENE10) credit (only applicable for schools and higher education), a configuration screen allows the user to select the free cooling options that will be deployed (Confirm free cooling strategies): New Features 20

Water and water recycling (WAT1 and WAT5 credits) The water appliances can be defined through the Edit appliance data option in the navigator. This will show the following entry screen: New Features 21

Materials specification and responsible sourcing (MAT1 and MAT5 credits) The materials and constructions used within the building must be provided with a Green Guide rating, and given an appropriate Ecopoints building type. This is done through the new Edit Green Guide ratings entry in the navigator, which launches the dialog below. The MAT5 credit requires further information not gathered by the <> and therefore cannot be automatically calculated. However, the MAT5 materials report provides all the appropriate materials information for easy entry into the appropriate BREEAM calculator. New Features 22