Electrical Preventive Maintenance (EPM) Program

Similar documents
HARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

IMPORTANT INSTRUCTIONS READ & SAVE

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

IMPORTANT INSTRUCTIONS READ & SAVE

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put Into Perspective Electrocutions Can Be Prevented

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

Electrical Safety. Don't allow trees near power lines to be climbed. Keep ladders, kites, equipment and anything else away from overhead power lines.

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

FLCH4R Garage and Utility Electric Heater

IMPORTANT INSTRUCTIONS

ELECTRIC STOVE HEATER Models: FS2213B

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Property risk solutions

IMPORTANT SAFETY INFORMATION:

USER'S MANUAL PGE Single Package Rooftop

Warehouse Operations Safety Inspection Checklist

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

RE: Primary Manufacturing Standards

Electrical Safety Requirements

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Turin LED Ceiling Fan

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Wet/Dry Vacuum Kit

User s Information and Installation Instructions

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

Wall Mount Electric Fireplace

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

MaxLite LED Round Pendant Highbay Series

-SAMPLE- Safety Inspection Checklist: Manufacturing

With Remote Control. English

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

User s Information Manual

Infrared Portable Space Heater

User s Information Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Gallery Electric Fireplaces

Fire Prevention Plan

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

ELECTRIC FIREPLACE CONVERTER KIT OWNERS MANUAL Model Number: EF05-23

ELECTRIC FIREPLACE WITH MANTEL MODEL WS-Q-03 OWNERS MANUAL

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

Dr. Infrared Heater Elite Series

Installation & Maintenance Instructions

Bathroom Exhaust Fan

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Infrared Portable Space Heater

Installation & Maintenance Instructions

Hardwired Electric Garage Heater

The Family Ceramic Heater

Fire Prevention Plan

Guide To Troubleshooting INEFFICIENT COOLING FANS

Infrared Portable Space Heater

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

User s Information Manual

ELECTRIC FLAT PANEL FIREPLACE HEATER

HI Industrial Utility Heater HI Soleus Air International

ELECTRIC FLAT PANEL FIREPLACE HEATER

Electric Garage Heater

WARNING FIRE OR EXPLOSION HAZARD.

Installation Instructions Remote Blowers

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Wall Hanging Mode. Pedestal Mode

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

Hardwired Electric Garage Heater

ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL

HEATER. Fan Forced IMPORTANT INSTRUCTIONS READ & SAVE OWNER S MANUAL. Model No.: DR W 120V 60Hz DR W 240V 60Hz

2014 National Electrical Code & NFPA 70E/Arc Flash

With Remote Control. English. Model

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Installation Instructions Millennia Cooktops

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Progressive Safety Services LLC 1

User s Information and Installation Instructions

Electrical Safety Program

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

10QT AND 6QT BACKPACK VACUUMS

Com-Pak Heater Benefits You Can Depend On Com-Pak Models Line Model w/o Model w/ Voltage Thermostat Thermostat Watts Amps (1) (2)

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

OKB, OKD, & OKH Series

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Stillwater Area Community Services Center Inc.

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

breeze easytm model # F100-1W

Transcription:

Electrical Preventive Maintenance (EPM) Program Only qualified and properly trained persons may work on electric circuit parts or equipment. Such persons shall be capable of working safely and shall be familiar with the proper use of special precautionary techniques, PPE, insulating and shielding materials, and insulated tools. Electrical panels and equipment needs to be de-energized prior to being serviced following proper lockout/tag out procedures, whenever possible. If it is not possible to de-energize the electrical panel or equipment, proper safety procedures must be in place following NFPA 70E: Standard for Electrical Safety in the Workplace. ALWAYS READ AND FOLLOW INSTRUCTION MANUALS AND SAFETY WARNINGS. This program and checklist does not purport to set forth all hazards nor to indicate that other hazards do not exist. They are intended for the purpose of assisting you in loss control and safety procedures. These recommendations do not guarantee compliance with local, State or Federal regulations. Neither Hortica nor any of its employees shall be liable in any manner for any personal injury, bodily injury, property damage or loss of any kind arising from or connected with this program or checklist. No responsibility for implementation, management, or operation of loss control and safety procedures is assumed by Hortica.

Hazard Identification: Electrical Preventive Maintenance (EPM) Program Electrical related fires are a common occurrence. Property damage and/or physical injuries due to electrical fires can be devastating. Every year, electrical fires result in hundreds of deaths, thousands of injuries and hundreds of millions of dollars in property damage. While some fires are caused by faulty products, many more are caused by the misuse and poor maintenance of electrical equipment, incorrectly installed wiring, overloaded circuits and misapplied extension cords. Electrical equipment deterioration is normal and equipment failure is inevitable. However, equipment failure can be delayed through appropriate electrical preventive maintenance. In addition to normal deterioration, other potential causes of equipment degradation can be detected and corrected through EPM. Among these are load charges or additions, circuit alterations, improperly set or improperly selected protective devices, and changing voltage conditions.

An effective Electrical Preventive Maintenance Program should consist of the following essentials elements: Management commitment Responsible and qualified personnel employee training Regularly scheduled inspection Survey and analysis of electrical equipment and systems to determine maintenance requirements and priorities Programmed routine inspections and suitable test Accurate analysis of the inspection so proper corrective measures can be prescribed Performance of necessary work Concise but complete records Evaluation of repairs and failures to predict future problem areas Inventory of spare parts for critical components During the development of your plan, you should take these basic steps: Compile a listing of all equipment and systems Determine which equipment and system are most critical Develop a system for monitoring Determine the internal and/or external personnel needed to implement and maintain the EPM Program Develop a Contingency Plan to deal with outages, equipment failures, etc. An electrical distribution system is typically comprised of a network of circuits, including wiring, circuit breakers, fuses and possibly transformers. The electrical distribution equipment should be periodically thermally imaged as well as physically inspected. This inspection should include: Hazard Identification Switchgear, switchboards, and panel boards Circuit breakers Fuses Disconnect switches Contactors and relays Protective relays Fans, motors and motor controls Busway and bus duct circuit breakers Transformers (if outdoor, it may be owned and the responsibility of the utility company)

Please keep an eye out for Corroded wiring, deteriorated wiring and deteriorated sheathing Frequently blown or tripped fuses and circuits Hot spots Other areas Lighting o Unprotected light bulbs can be hit and broken, and may create sparks, potentially causing a fire. o Flickering or dimming lights may indicate a short in the wiring, dangerous arcing, or an over-extension of the electrical systems. o Multiple dimmed lights can also be a symptom of an overloaded circuit. Extension Cords o Check for missing prongs o Damaged cords o Overload o Spliced or unprotected o Running through walls and ceilings o Self-inspection program of extension cords o Replace, not repair, damaged cords o Minimize use through installation of permanent wiring o Use GFCI adapters in wet areas Housekeeping Good housekeeping greatly reduces fire risks. When electrical distribution equipment is in a separate dedicated room, the room should be temperature-controlled, well ventilated, clean, and dry to prevent moisture and excessive room temperatures that can degrade electrical materials. Additionally, keeping the room properly sealed will keep it free of dirt, dust, rodents, and pesky bugs that can get into the cabinets and degrade the equipment and potentially start a fire. It is also important to keep combustible material away from electrical distribution systems. Keep in mind that electricity can arc or jump through the air as a path to the ground and ignite combustible material in the vicinity. Implementing an effective EPM Program will provide tangible and intangible benefits including improved safety, lower repair cost and less equipment downtime. Additionally, as part of an established written Electrical Safety Program, OSHA s Lockout/Tagout Standard Operating Procedures should be consistently followed by employees and contractors to help ensure personal safety.

COMPONENT ITEM # JOB PERFORMED Responsible for the Inspection: Date of Inspection: / /

Electrical equipment room #: Check 1 Access door is marked and in working order 2 Free of excessive dust, dirt and debris 3 No storage. Clearance of at least 36 inches from panels 4 Adequate lighting 5 Free of water or potential sources of water 6 Check for burning or ozone odors 7 Room is well ventilated Recommendations Vacuum the panels and room to remove dust, dirt and debris Wipe down with lint free rags and solvents if needed, nonflammable solvents only Check for signs of moisture or contamination If present, check that windows are in working order Verify that surface mounted wiring is labeled UF-B, UV resistant and is located in areas not subject to abrasion or physical damage For conduit wiring, verify Schedule 40 PVC is used and wire is for wet locations i.e. THWN. Verify that electrical raceways and cable trays are used exclusively for electrical conductors

Electrical Panel #: Check 8 Panel doors in working order 9 Front panel is present and no open slots are present 10 Free of excessive dust and dirt 11 Seal and gaskets are installed 12 All the wiring is reaching completely into the box and properly secured 13 No punch-out missing 14 All the breakers are labeled 15 If present, check for heater elements 16 If present, check for fans 17 Check for arc flash protection warning signs 18 Check for identification of disconnecting means and circuit directories for panelboards, switchboards, switchgears and similar equipment Switchgears (Insulators, Supports and Connectors) 19 Check for signs of cracking, broken pieces or any sign of physical damage 20 Free of dirt and debris 21 Check for evidence of moisture 22 Check for evidence of tracking, arching or overheating 23 Check for bolts and connecting devices for signs of physical damage 24 Ensure bolts have proper tightness 25 If present, copper and aluminum conductors, check for galvanic action 26 Check for insulation: deterioration, cracking, flaking or overheating 27 Inspect for missing parts Recommendations If exposed to the environment, increase the frequency or maintenance Clean all ceramic materials Vacuum dirt and debris Exercise circuit breakers annually Bi-annual interior inspection/cleaning of distribution panels by licensed electrician

Battery Station/Chargers # Batteries 28 Battery surface clean of dust and dirt accumulation 29 Check for all terminals and connections being tight and clean 30 Check for corrosion on battery terminals 31 Check for stranded cables, corroded or separated 32 Check electrolyte levels and specific gravity. Charger 33 Free of dirt and debris 34 Check for terminal connections 35 Check that all relays, lights, and other indicating devices are working properly Recommendations Batteries emit explosive gases while charging, allow no open flames or sparks Battery room should be ventilated using a rated fan No smoking should be permitted Electric Motor # Electric Motors 36 Check for damage caused by dirt, loose parts or foreign objects 37 Check air inlets are not blocked 38 Check for evidence of moisture and/or dirt build-up 39 Check for unusual noises, leaking seals or high vibration 40 If present, check oil level gages 41 Check for degradation of foundation, bed plates, anchor bolts 42 If present, check for oil ring turning 43 Check for evidence of leaking oil and water from piping and connections 44 Check for scheduled lubrication according to manufacturer's instructions 45 46 47 For critical motors, check bearings daily using a stethoscope or infrared scanner (or camera, if appropriate) Check bearing surface temperature with a thermometer, electronic temperature sensing devices, or stick-on temperature indicating labels Check belt tension; belts should have about 1 in. of play; sheaves should be seated firmly with little or no play

Additional Check 48 Verify that wiring methods are securely fastened in place, supported independently 49 Verify that boxes are installed at junction, splice, outlet, switch, and pull points 50 Identify wet and damp locations and the suitability of boxes and fittings 51 52 Verify that cabinets or cutout boxes are suitable and properly installed in any wet or damp locations Verify that cables are secured to cabinets and cutout boxes or that the conditions for cables with nonmetallic sheaths are met 53 Verify that any switches in wet locations are properly installed in waterproof enclosures 54 55 Verify that the point of attachment for an overhead service drop is adequate and will provide minimum clearances Verify that GFCI protection is provided for receptacles in bathrooms, near sinks, outdoors, on rooftops, indoor wet areas, outdoor areas and in garages 56 Check transformer installations for adequate ventilation and spacing from walls and obstructions 57 Periodic transformer oil testing