Development of On-line Instrumentation and Techniques to Detect and Measure Particulates

Similar documents
A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

The FEL Facility Optical Diagnostics and FEL Characterization

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

WHAT IS LASER ULTRASONIC TESTING?

FLIM/FFS and Nanoimaging Upgrade of Olympus confocal microscopes

Electronic Refrigerant Leak Detector DE-FG36-98G Micronic, Inc. Elie Talamas, Jr. Period: 10/1/99 to 12/31/99

Laser Diagnostics and Optical Measurement Techniques

FINAL ABSTRACT. CRADA TITLE. Miniature Transducers for Flight Test Unit Instrumentation - Magnetic Field Detector CRADA NUMBER: LA98C10367.

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

Building and Characterizing 14GHz InGaAs Fiber Coupled Photodiodes

Gas Temperature Measurements with High Temporal Resolution

Spectrum Detector, Inc.

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

Current Research Topics in Optical Sensors and Laser Diagnostics

An FT-NIR Primer. NR800-A-006

The Optical Scattering Calibration System at SNO+ IOP 2015

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

Measurement of light scattering in deep sea

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Recent Advances in Solid State Lasers and Nonlinear Optics for Remote Sensing

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

On-chip optical detectors in Standard CMOS SOI

3kW 6kW, QUBE Fiber Lasers

Polarized Light Scattering of Smoke Sources and Cooking Aerosols

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

High-Altitude, Aerial Natural Gas Leak Detection System

Variable Temperature Options for Optical Experiments

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report April 1,1995 to May 31,1995

Customized MCPs for Analytical Instruments. An MCP for every application

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Industrial presentation. Philippe Marchais - July 3rd, NDIP Tours

TacBio: A UV-based Biological Aerosol Detector. TacBio Overview Page 1

Detection of Inherent and Laser-Induced Scatter in Optical Materials

Atmospheric Super Test Beam for the Pierre Auger Observatory

Investigation of the Potential Use of Blue Light in Forward Scattering Optical Smoke Chambers to Detect all UL217 Fires in the New Standard

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC

DURIP: Fast Oscilloscope and Detectors for Air Laser Research

CRUSH: Cognitive Radio Universal Software Hardware

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

AEROSOL SPECTROMETERS

Optical Time Domain Reflectometry (OTDR)

VIEW500 USER-FRIENDLY STANDARD OTDR

ISO/TS TECHNICAL SPECIFICATION

G4 Pulsed Fiber Laser

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics


SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

More Precision. thicknesssensor // The sensor for precise thickness measurements

Development and demonstration of a diode laser sensor for a scramjet combustor

CCD and CID solid-state detectors

/,6 REMOTE MONITORING DESIGN CONCEPTS FOR SPENT FUEL STORAGE FACILITIES

Lasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors

OptoYag M. clear vision

NX7363JB-BC. Data Sheet R08DS0009EJ0200 Rev.2.00 LASER DIODE. Sep 19, 2010 DESCRIPTION FEATURES

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

First results and developments of the multi-cell SDD for Elettra and SESAME XAFS beam lines

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

R&D Fast and lightweight EIC integrated tracking system Barrel MicroMegas & Forward Triple-GEM

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Fiber Optics and Liquid Level Sensors Line Guide

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL

SUNSTAR 传感与控制 TEL: FAX: DATASHEET Lightingg Solutions 1100 Series High Stabi

Characteristics of different sensors used for Distance Measurement

Construction of a Calibration System for Power Responsivity of Optical detectors Using Different Laser Sources

Specifications Wavelength Range: 190 nm to 800 nm continuous

A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

APPLIED. OMA-406R Rackmount Process Analyzer

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.

May 28th, Réseau Fibré Métrologique à Vocation Européenne

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Transcription:

Development of On-line Instrumentation and Techniques to Detect and Measure Particulates Quarterly Technical Progress Report From Oct. 1, 2002 to Dec. 31, 2002 Principle authors: Sheng Wu, Steve Palm, Yongchun Tang, William A. Goddard III Date Report was issued: Jan. 28, 2003 DOE Award number: DE-FC26-02NT41581 Name and Address of Submitting Organization: California Institute of Technology 1200 East California Blvd., Pasadena, CA91125 1

Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial products, process, or services by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. Abstract In the first quarter of the project, we reviewed many past references about using light scattering to characterize particulate matters. We also constructed light sources, detection systems and PM synthesizer for the project. 2

Table of Content Title Page... 1 Disclaimer and Abstract... 2 Table of Content 3 Executive summary.,.....4 Experimental....,.....5 Results and Discussion.. 10 Hypothesis and Conclusions....11 References.12 3

EXECUTIVE SUMMARY The first quarter of this project went smoothly ---- we finished acquisition of major equipment needed for the project in a week and got into full speed immediately; we developed laser diode drivers, CCD detectors and mono-sized particulate generators; our reference/literature investigation gave us a more detailed understanding of the light scattering process and let us pay special attention to several PM scattering cases, and we are also on the way to write computer simulation programs for the multi-wavelength scattering process. 1. The major equipment that we acquired for this project include: 1GHz bandwidth oscilloscope, Model LeCroy 534 with 16M (4CH x 4M) of memory, this allows us to debug all the electronics for the experiment as well conduct data acquisition during the experiment. An existing multi-functional ADC card from National Instrument is already available for final experimental setup. Hamamatsu PMT detector (R957-H08) detector with integrated high voltage assembly, this allows us to detect light scattering at very low PM concentrations Optical tables, 2 pcs will give us enough room to conduct experiment SRS DG345 function generator, this gives us the capability to provide various modulation to the lasers as well as the timing for the experiment SRS 834 lock-in amplifier and NewFocus Chopper system, this will allow us to collect signal in modulated form Diode lasers with 6 different wavelengths ranging from 635nm to 980nm were acquired Diode pumped CW laser at 1064nm and 532nm were acquired Laser particle scattering counter, Model 227A from Pacific Scientific Instruments, this is a hand-held device that could detect particle density at fixed sizes (0.5 µm and larger for one channel and 0.7, 1, 3 and 5 µm for the 2 nd channel). 2. Electronics, optical and PM synthesis equipment we have developed Laser diode drivers with external modulation bandwidth about 1MHz, including low current models (<250mA) and also high power models (>5A), have been constructed. These laser drivers will drive up to 12 different lasers at the same time. Optics for construction of passively Q-switched lasers have been acquired, this will enable our construction of lasers at 266nm and 355nm. Detector array system based on CMOS array detectors. The detector array we constructed could have integration time down below 1 µs and dynamic range up to 80dB We have also designed and constructed a mono-sized PM generator, and we will test it with the laser particle scattering device (Model 227A from Pacific Scientific Instrument) acquired above. We are also checking the possibility of testing it with a more precise PM measurement meter from Wyatt Technology. 3. Literature review We found more related literature on PM light scattering, especially the special issue in Meas. Sci. Technology, Vol 9, 141-220, 1998, which shed light into light scattering on irregular, i.e. non spherical, particulates. 4

From the vast amount of data in PM scattering in water (www.wyatt.com), we also found that we should compare our multi-wavelength scattering results with results obtained with the multi-angular detection scheme. We also are looking into other possible information, besides physical sizes, that we could collect with multiple lasers. This include laser induced fluorescence and Raman scattering. The detector array that we build therefore should have the capability to look at these signals. EXPERIMENTAL 1. Data acquisition system The 1GHz bandwidth digital oscilloscope also come with 16MB of memory, thus allow us to record data over a very long period of time. Since the fluctuation of light scattering signal could be huge over the time, this capability of the scope will help our initial identification/analysis of signals. In the final experimental setup, even longer data from multiple detectors (e.g. 3) have to be acquired, we already had an ADC card from National Instrument (Model 6023E), which has a maximum data sampling rate of 200kHz with 12-bit resolution and 16 single ended/8 differential input channels. Programs based on VB and Labview are already available, only minor changes are needed to adapt for this project. 2. Laser sources Some more details about the diode lasers we acquired, they come in the following wavelengths and power, Wavelength 635nm 650nm 780nm 810nm 830nm 980nm 532nm 1064nm Power (mw) 30 40 80 1000 30 30 30 200 Package TO Cir. TO Bare C-mnt TO FC DP/CW DP/CW Note: Cir.TO: Circular output (from Blue sky) in a TO can, C-mnt: C-mount bare chip, FC: Fiber coupled, DP/CW: Diode pumped CW operation (could be modulated at low frequency up to 10kHz) We have also acquired optics for construction of the 355nm and 266nm sources, these optics are based on passively Q-switched lasers (Cr:YAG and Nd:YAG). We hope to generate laser pulses around 1ns, pulse energy over 300 µj at 1064nm, and at a repetition rate of over 1kHz. The table blow lists the optics set that we acquired, L1(mm) L2(mm) S1 S2 Configuration 1 0.75 0.25 HR1064, HT808 R=25% 1064 Configuration 2 1 1.5 HR1064, HT808 AR/HT 1064 Configuration 3 3 1.5 HR1064, HT808 AR/HT 1064 Configuration 4 3 3 HR1064, HT808 R=25% 1064 The schematic for the diode pumped passively Q-switched laser is given below 5

LD driver TEC driver LD Collimation + focusing S1 Nd: Cr: YAG YAG YAG or Nd: YAG S2 L1 L2 L3 Figure 1. Schematic for the diode pumped passively Q-switch laser In all configurations, S1 and S2 have parallelism within 5sec, cross sections of 3x3mm. Cr:YAG has absorption about 6cm -1 at 1064 nm. The 4 combinations above should give us laser pulses with pulse width ranging from 300ps or less to 4ns, and pulse energy from 10µJ to 300µJ. The passively Q-switched lasers are often continuously pumped, with a repetition rate ranging from 1kHz to 10s khz, and the timing between the pulses have a jitter of ~100ns. After review literature, we found that we need to have the capability of externally trigger the laser pulse. The repetition rate should be <1kHz, and most often ~100Hz. The low repetition rate is decided by the data acquisition and analysis speed. Reducing the repetition rate has several advantages. First, the lower repetition rate will lower the pump laser duty cycle, therefore reduce the thermal lensing effect and increase the gain volume. Second, when external triggered, we have a better control of the timing. As the delay between the rising edge of the pump laser current pulse and the Q-switched laser pulse is decided by the gain volume and pump laser power, we could make sure that the Q-switched laser pulses come in at the desired time with a jitter less than 10ns. This is enough since the motion of particles in the air is more than 1 µs. The drivers we designed is based on the WLD3343 chips from Wavelength Electronics. Each WLD3343 could pump out 2.5A, and we use the parallel link to annex two WLD3343 together to provide the 5A required. 3. Array detector We wish to have an array detector that could allow sub microsecond integration. Our passively Q-switched laser generate intense pulses and allow us to conduct such experiments as LIF and Raman scattering, and the signal is best collected within the short time window, instead of having to integrate over a long time when the noise is also introduced. We developed two kinds of array detectors. The first one is based on regular scanning detectors, such as a linear CCD array detector used in scanners. Such CCD chips are already widely used in ultra-compact spectrometers, e.g. Ocean Optics S2000. But, the integration time of this CCD chips is limited to more than 1ms, because the time it takes to scan through the 1024 elements is limited by the clock rate (1ms is needed when the scan clock is at 1MHz). Also, the 1024 pixels are not exposed to the same time window. Based on an array detector chip from Photon-Vision Systems (PVS), we designed a board for their LIS-1024 chip, it could have dynamic range of 80dB while the scanning clock could be as high as 1MHz. This board could also be externally triggered. Our design allows this board to be easily changed to fit other CCD detectors, including the ultra-deep well photodiode array, Hamamatsu S3094. 6

We also developed a board based on PVS ELIS1024, this chip features the short integration window option, which allows us to integrated all the pixels for a very short while (<1µs) at exactly the same time. Also, this chip allows pinning of the 1024 pixels, thus reducing the total of scanning pixels when collecting data (the effective data pixels could be reduced to 64). This not only reduces the time to read the pixels (as short as 64µs is needed when the clock is at 1MHz), but also provide the on-chip integration of the pixels where their signal are originated from the same wavelength and should be collected together. The well depth of the LIS1024 and ELIS1024 are all larger than the CCD array detectors such as the SONY ILX511 used in the OceanOptics S2000 spectrometer. The deep well depth will allow integration over a relatively longer time, while the short integration window could allow transient signal detection, such as LIF and Raman scattering. ILX511 LIS1024 ELIS1024 S3903 Well depth (e - ) /pixel 350,000 8,000,000 800,000 31,000,000 Integration time >1 ms ~1 ms <1 µs >31ms 4. Mono-sized particulate generation We designed and constructed a mono-sized particulate generator. We will first use mono-sized particles that are commercially available from chemical suppliers, such as Aldrich. These monosized particles are not soluble in water, and we could just first mix the particles with water. A neubilizer will vaporize the water+pm colloidal mixture, and then the flow is pass through a dryer system which gets rid of water. The PM thus have mono-size distribution and know chemical properties. A recirculation system will bring back the PM material to mix with water again and continue the generation for the experimental study. We are also designing another PM synthesizer, which could allow the generation of mono-sized liquid form aerosols. The designed figure is given below. The chemicals could be dissolved in a certain liquid (e.g. methanol). The liquid is dragged by the high pressure gas jet and experiences a supersonic expansion in the normal pressure chamber. The free expanding beam will form aerosols of different sizes in the air, and a mono-sized aerosol could be picked up by a crossing high- pressure air beam and pushed toward the exiting aperture. After studied in a sealed window chamber, the aerosol material will be recondensed on a cooling/impacting surface and recirculated for continuous study. This design is much more challenging than the first design, because the liquid form aerosols are the tough most to measure/verify their sizes. We will verify our design by using the laser particle sizing instrument we acquired. 7

Normal pressure chamber Figure 2a. 3-D view of the water aerosol generator Figure 2b. Sectional view of the water aerosol generator Figure 3. Schematic of the WLD3343 x 2 + HTC-3000 board 8

Figure 4. External current modulation (black) and the actual current (green) and the laser pulses (yellow) Figure 5. Picture of the TC+LD board with the green laser on the optical table. 9

RESULTS AND DISCUSSION We constructed a laser diode driver with rise/fall time less than 400ns. We tested this driver with a CW pumped 532nm Nd:YVO4+KTP laser first, and the results are presented in figure 3, 4 and 5. We could see that the rise/fall time of the pump laser and relative jitter between the 532nm laser pulse and the laser current rise time (note that this jitter will be much smaller when passively Q-switched laser is used). The successful operation of the laser diode drivers will give us the capability to externally trigger the semiconductor lasers as well as passively Q-switched lasers. In the next quarter, we will use the 5A driver to drive a 2W pump laser diode (from OSRAM SPl CG81), and the laser diode will pump the passively Q-switched laser optics that we acquired. We hope that we will get all the light sources ready by the end of the second quarter. The detector array with sub-µs integration window will enable us to conduct LIF and Raman scattering measurements. The figure below shows the Shutter Time is set at 50µs. Much shorter time has been demonstrated to below 1µs. Figure 6. Figure shows the timing for the logical control of the ELIS1024, and the RSET (reset from external trigger) is independent of the camera CLK (clock) on board. 10

LIS1024 ELIS1024 Array Chips board Clock and Logic board Figure 7. The array detector assembly includes the Array Chips board and the Clock and Logic board. We successfully constructed a recirculating neubilizer that could generate mono-sized insoluble (in water) solid particles in the air. We are also in the process of constructing a PM synthesizer that could generate liquid form aerosols. We need to test the particle size distribution using the laser particle scattering meter we acquired and also the more sophisticated DAWN instrument. Literature review We did a more thorough literature review of light scattering techniques for particulate study. One of the most interesting literatures comes from the special issue from Meas. Sci. Tech. Vol. 9, 1998 (page 141-224). Here, 7 papers discussed the light scattering results on irregular, i.e. nonspherical, particulates. The results clearly show that special cares, e.g. time average, must be taken to treat the results from such irregular shaped particulates. Since in the real world, particulates are often generated in irregular shapes, these results convince us that we must consider this effect both in the theoretical simulation model development but also in the experiments. We also run into the reference database of Wyatt Technology, who now focuses on particulate detection in liquid/biological systems. But their instruments, i.e. DAWN scattering sphere, are also widely used in particulate characterization in the air. We will also calibrate our instrument against systems similar to DAWN. We are in the process of writing simulation code based on the latest literature resources. We will include in the model the simulation of non-spherical shaped particles. There are 2 such multi-angular DAWN instrument available on Caltech campus, and we will be able to compare our multi-wavelength results with results from these DAWN instruments. HYPOTHESIS AND CONCLUSIONS This past quarter proceeded as planed and we successfully prepared the array of CW laser sources, and the laser drivers with high current output and fast rise time are ready for the construction of passively Q-switched UV laser sources. We also constructed a PM generator that 11

could generate solid mono-sized particles, and this generator is ready to conduct experiment. We also found some latest results on PM light scattering on irregular particulates, and the results give us new directions for our simulation modeling. Planed schedule from the statement of work Task Technical Milestone Schedule 1. Assembly of the multiwavelength light source Ready diode & DP chip lasers, drivers Month 1-6 Ready beam combination system Month 1-6 2. Construction of the PM Verify that monosize PM are Month 1-6 synthesizer 3. Simulation of Ralyeigh and Mie Scattering 4. Laboratory demonstration of instrument 5.Application of the PM analyzer to a combustion environment: engine intake area 6.Application of the PM analyzer to a combustion environment: engine exhaust 7. Applicability assessment for PM emissions from coal fired power plants generated Literature review Month 1-3 reviewcomputer program that could generate simulated scattering spectrum Experimental scattering spectrum database for different PM sizes Compare with theory and conventional PM monitoring data Correlation of our instrument data with conventional PM monitoring data Correlation of our instrument data with total PM mass emission, new data (PM size and chemical composition) about insitu PM monitoring Design/modify our PM instrument for smoke stack PM monitoring 8. Instrument design optimization Optimize the instrument during different experiments Reference: Month 1-6 Month 7-18 Month 13-24 Month 13-24 Month 24-30 Month 13-36 1. J.J. Zayhowski, C. Dill III, C. Cook, J.L. Daneu, OSA TOPS Vol.26,178-186, 1999 2. Special issue in Meas. Sc. Tech. Vol. 9, 141-220, 1998 3. For particulate scattering database, please go and check www.wyatt.com 4. Comparison of the array detectors, www.oceanoptics.com, www.photon-vision.com 12