Digital Display DS 52 in wall housing. Order no

Similar documents
FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

DP 300 mobile dew point instrument

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

WIO200 Water In Oil measuring instrument

Dew point set DS 400

SCHMIDT LED Measured Value Display MD Instructions for Use

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

EN-ENGLISH INSTRUCTION MANUAL. METPOINT LKD 300 Leak Detector (LD109) For leak detection in pneumatic systems.

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

WIO200 Water in oil sensor

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Snifter ATEX22 VERSION. User Manual. Distributor

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

Process Alarm Module RTA 421

Power Supply Display Module PSDM. Installation and Operation Manual

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Screw-in heater (EHK)

Refrigerated air dryers

Danfoss gas detection units

R1000 / R1040 / R1080

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

Manual CME420. Multi-functional current relay, AC, overcurrent/undercurrent/ window discriminator function CME420_D00034_02_M_XXEN/05.

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Operating Manual. English. Refrigerators for chemicals KRC 50 KRC 180

User Guide. Stainless Steel Filter Housing Heater

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006

COMPACT FLAME CONTROLLER CFC 1000

MO n : 12JMC rév A

Warranty Registration

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

Warranty Registration

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

02/11/2015

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

PolyGard 2-channel Gas Controller MGC-03

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

Mark 25 Ultrapure Water Conductivity Analyzer

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Software Version 2.01 LEVEL MONITOR MODEL 220

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

The A-series Eletta Flow Monitor with local indication and analog output

WIO 200B and WIOI200B Water in oil sensor

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Superdew 3. Hygrometer. Operating Instructions

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

TER Active Room Temperature Sensor (Controller),

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

Operating Manual VMD420

Danfoss gas detection units

M3050 Detector Operator s Manual

DICTATOR Hold-Open Systems for Hazardous Areas

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

COMPACT FLAME CONTROLLER CFC 2000

CO2 Sensor User and Installation Guide

FLAME AMPLIFIER MODULE 3001

INSTALLATION INSTRUCTIONS

Instruction Manual WARNING

MBCE-110/230FR Flame Sensor Module

DOC JAN06 LT 200

GMH 285 / GMH 285-BNC

Controllers. Instruction Manual WARNING

CTT8 TEMPERATURE MONITOR DEVICE

CONTROL DEVICE SLIDETRONIC HD

Electronic Temperature Controller 70304,

VME421H Voltage and frequency monitor

VME420 Voltage and frequency monitor

Instructions for the fan motor control system with integrated wiring terminals SILVER C

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P

OPERATING INSTRUCTIONS. Waterbath WNE 7-45 WPE 45. Oilbath ONE 7-45

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Temperature-Relay TR210

ß-Aerosolmonitor FHT 59 C

Preamplifier Power Supply PPS-02 user's guide

eed quality electronic design USER s MANUAL

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Greentrol Automation, Inc.

Supplement to operating and installation manual no for the VR 81 remote control unit

Water Detection Controllers

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

FSW300 Series Flow Switch

Original instructions JSNY7 Magnetic switch

MCS 4000 Control Panel

Incutrol/2 Regulator

FLAME AMPLIFIER MODULE 3001D

Series DH3 Digihelic Differential Pressure Controller

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Transcription:

Instruction Manual Digital Display DS 52 in wall housing Order no. 0500 0008 for 0/4 20 ma sensors 1

Table of content Page Introduction 2 Safety instructions 3 Short-form instruction DS 52 with 0/4 20 ma sensors 4 Menu with all functions 7 Lock operation menu, enter code, lock alarm values 8 Calibration/adjustment 9 Warranty 9 Technical data 10 Order information 11 Notes 12 Contact 13 Introduction Dear customer, Thousands of customers buy our high standard products every year. There are a few good reasons for doing so: The cost-performance ratio - reliable quality at a fair price. We have the ideal solutions for your measuring tasks based on our expert experience gained over 20 years. Our high quality standard. Of course, our instruments carry the CE symbol required by the EU. We issue calibration certificates and hold seminars. Also after the purchase we do not leave you out in the cold - we offer a good after sales service. Our service grants you a fast help. Measuring instrument conforms with DIN EN 61326 2

1. Safety instructions Observe measuring ranges of the sensors! Observe the admissible storage and transportation temperature as well as the permitted operating temperature (e. g. protect the instrument from direct insolation) Adjustments and calibrations should only be carried out by qualified employees from the measurement and control technology branch. We offer you to take back the instruments DS 52, which you would like to dispose of. The manufacturer cannot be held liable for any damage which occurs as a result of non-observance or non-compliance with these instructions. Should the device be tampered with in any matter other than a procedure which is described and specified in the manual, the warranty is cancelled and the manufacturer is exempt from liability. CS Instruments GmbH offers no guarantee for the suitability for any other purpose and is not liable for errors which may have slipped into this operation manual. CS Instruments GmbH is also not liable for consequential damage resulting from the delivery, capability or use of this device. Initiation (electrical connection) When operating electrical instruments it is unavoidable that certain components are energised dangerously. Work at electrical installations or equipment is only allowed to be carried out by electrical technicians or instructed staff under the guidance and suvervision of an electrical technician according to the electrical regulations. Warning Any non-observance of the warning notes may cause grievous bodily harm or property damages. Qualified staff has to be well familiar with all warnings according to this instruction manual. The correct and safe operation is subject to a proper transport, professional installation and accurate initiation. The following notes on safety are applied in order to stress safety relevant procedures in this instruction manual - every note is marked by a corresponding icon. This symbol means: Note! "Note" marks activities or procedures which have a fundamental influence on correct operation. Any non-observance may possibly lead to subsequent damages. This symbol means: Warning! "Warning" indicates activities or procedures which may lead to a safety risk for persons and property damages in case of non-observance. 3

2. Short-form instruction DS 52 with 0/4 20 ma sensors Power supply and alarm connection: AC Power 230 VAC 50 Hz Attention! Mains voltage! 2.1 Connection of CS Instruments sensors NC und COM are closed in case of: - alarm exceeding - voltage drop - sensor break * A bridge circuit is inserted ex factory. For signal transfer please remove the bridge circuit and attach the connection cables. Attention: Current loop has to be closed! 4

CS Sensor Terminal connector M12 FA 510 1 2 3 4 5 Sensor V+ SIG GND Braun / brown I I+ I- 1 2 3 4 5 6 Blau / blue Grau / grey * A1-2 A1-1 230 VAC PE N L 7 8 9 101112131415 CS Sensor Terminal connector M12 FA 515 1 2 3 4 5 Sensor V+ SIG GND Braun / brown I I+ I- 1 2 3 4 5 6 Blau / blue * A1-2 A1-1 230 VAC PE N L 7 8 9 101112131415 * A bridge circuit is inserted ex factory. For signal transfer please remove the bridge circuit and attach the connection cables. Attention: Current loop has to be closed! 5

2.2 Connection of third party sensors DS 52 has one analogue sensor input for connection of sensors with 0/4 20 ma signal.the sensor input is configurated on our premises (according to the customers specification in the order). Sensors with 0/4 20 ma-current signal are connected as follows: V+ max: 24 VDC 100 ma * Ab Werk ist eine Brücke eingebaut. Zur Signalweiterleitung bitte Brücke entfernen und Anschlussleitungen anbringen. Achtung: Stromschleife muss geschlossen sein! * A bridge circuit is inserted ex factory. For signal transfer please remove the bridge circuit and attach the connection cables. Attention: Current loop has to be closed! 6

3. Menu with all functions The operation is effected via 4 keys: and as well as, in order to access the menu/to confirm selection and Back The operation in detail: -45,0 currently measured value press for the duration of 3 seconds AL - 1 8.0 alters With with alarm threshold 1 scaling up, scaling down At - 1 nor nor = Normal - means Alarm 1 in case of "threshold exceeding" alters press shortly rev rev = Reverse - means Alarm 1 in case of "threshold undercut" HY - 1 2.0 alters With with Hysteresis 1 scaling up, scaling down press shortly AL - 2 8.0 alters With with alarm threshold 2 scaling up, scaling down At - 2 nor nor = Normal - means Alarm 2 in case of "threshold exceeding" alters press shortly rev rev = Reverse - means Alarm 2 in case of "threshold undercut" HY - 2 2.0 alters With with Hysteresis 2 scaling up, scaling down press shortly 7

4. Lock operation menu/alarm values - enter code - scale sensor signal The instruments operation (adjustment of alarm values) can be locked by means of a code. + + pressed at the same time for 3 seconds UCODE 0 dec-p 0.0 Code was stored Decimal point setting was stored SCALE 0 _ 20 Factory setting: UCode = 0. The menu points are not protected by a code and can be used by everybody. With and any code from 0 to 999 cab be set. This locks the menu point "Set alarm tresholds", they only can be changed if the correct code is entered at the beginnning of the menu.* If the menu should not be locked please enter Ucode = 0 resp. keep the factory settings without any changes. If the entered code has been forgotten please enter the code = 978 then the lastly entered code will occur. Set decimal point with and (0 0.000) Choose with and whether you want to connect a sensor with 0 20 ma signal or with 4 20 ma signal. 4 _ 20 4 ma 0 With and you can set the lower scaling value (4 ma resp. 0 ma) of your sensor 20 ma 500 With and you set the upper scaling value (20 ma) of your sensor Scaling for 4 and 20 ma was stored In order to access the measuring menu please press the ENTER key for 3 seconds. For further operation steps please see point 3. If you have entered a code please use this code in order to set the alarm values (see point 3. "Menu with all functions", page 5). 8

5. Calibration/adjustment At CS Instruments According to DIN ISO certification of the measuring instruments we recommend to calibrate and if applicable to adjust the instruments regularly at the manufacturer. The calibration intervals should comply with your internal specificaton. According to DIN ISO we recommend a calibration interval of one year for the instrument DS 52 including probes. 6. Warranty If you have reason for complaint we will of course repair any faults free of charge if it can be proven that they are manufacturing faults. The fault should be reported immediately after it has been found and within the warranty time guaranteed by us. Excluded from this warranty is damage caused by improper use and non adherence to the instruction manual. The warranty is also cancelled once the instrument has been opened - as far as this has not been mentioned in the instruction manual for maintenance purposes - or if the serial number in the instrument has been changed, damaged or removed. The warranty time for DS 52 is 12 months, the warranty time of the accessories is 6 months. Warranty services do not extend the warranty time. If in addition to the warranty service necessary repairs, adjustments or similar are carried out the warranty services are free of charge but there is a charge for other services such as transport and packaging costs. Other claims, especially those for damage occurring outside the instrument, are not included unless responsibility is legally binding. After sales service after the warranty time has elapsed We are of course there for you even after the warranty time has elapsed. In case of malfunctions please send us the instrument with a short-form description of the fault. Please do not forget to indicate your telephone number so that we can call you in case of any questions. 9

7. Technical data Housing dimensions Display Keypad Sensor input Burden analogue input Accuracy analogue input Sensor supply Voltage supply Outputs Operation temperature Alarm thresholds Hysteresis 118 mm x 92 mm x 133 mm LED red, 7 segments, height: 13 mm, 5 digits, 2 LED for switching outputs (alarm relays) 4 keys:, Back, Up, Down 1 x analogue input for sensors with 0 20 ma or 0/4 20 ma signal. Connectable in 2-/3- or 4-wiretechnologie possible with 24 VDC supply 100 Ohm max. < ± 20 µa, typical 10 µa 24 VDC with Polyfuse max. 100 ma 230 V, 50/60 Hz 2 x relays output, changer, 250 VAC, max. 3 A -10 C +60 C (storage temperature: -20 C +80 C) freeley adjustable 2 Ctd 10

8. Order information Description DS 52 - LED display in wall housing (118 x 92 x 133 mm), Supply: 230 V. Analogue sensor input for sensors with 4 20 ma or 0 20 ma signals. 2 alarm relays (change-over contact 250 VAC, max. 3 A), alarm values freely adjustable Order no. 0500 0008 Options Option for DS 52 LED display: Supply 24 VDC instead of 230 VAC, 50/60 Hz Z500 0001 Option for DS 52 LED display: Supply 110 VAC instead of 230 VAC, 50/60 Hz Z500 0002 11

Notes 12

Contact Advice Sale Service Sales office North Germany CS Instruments GmbH Am Oxer 28c 24955 Harrislee Phone +49 (0) 461 700 2025 Fax +49 (0) 461 700 2026 E-Mail info@cs-instruments.com www.cs-instruments.com Sales office South Germany CS Instruments GmbH Zindelsteiner Straße 15 78052 VS-Tannheim Phone +49 (0) 7705-97899-00 Fax +49 (0) 7705-97899-20 E-Mail info@cs-instruments.com www.cs-instruments.com 13