GAMMA RAY DETECTION PROBE MODEL SO16

Similar documents
LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

IAEA-SM-367/14/01 UTILIZATION OF FLUORESCENT URANIUM X-RAYS AS VERIFICATION TOOL FOR IRRADIATED CANDU FUEL BUNDLES

Technical Manual Ionisation Chamber MUSIC80

North American Technical Services

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

818 Series Low-Power Detectors

High Throughput Large Area Silicon Drift Detectors

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

XPIN -XT X-ray Detector Operation Manual

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

arxiv:astro-ph/ v1 17 Aug 2000

Freiburger Materialforschungszentrum SG Material Characterization & Detector Technology. Albert-Ludwigs-Universität Freiburg

Recent Advances in Mercuric Iodide Detector Fabrication and Instrument Development*

CZT/NaI Hybrid Hand-Held Performance Evaluation

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

Silicon Detectors Passivated Implanted Planar Silicon (PIPS ) Detectors for Industrial Applications and Physics Research OEM VAR

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

SILICON DRIFT DETECTORS

Indium Gallium Arsenide Detectors

Title: Semiconductor detectors with proximity signal

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

Development of a Fourth Generation Industrial Tomography for Multiphase Systems Analysis

Measurement system for detection of Radon in building

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

Provläsningsexemplar / Preview TECHNICAL REPORT. Nuclear medicine instrumentation Routine tests

Remote Gamma Imaging of High Dose Environments

Performance of a New Type of Electrical Cooler for HPGe Detector Systems

DIGITAL AREA RADIATION MONITOR

Portable Instruments For First Response & In-Situ Analysis of Radiation

Extreme High Count Rate Performance with a Silicon Drift Detector and ASIC Electronics

Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier

Single-sided CZT strip detectors

IFIN-HH, Hadron Physics Department infrastructure for ALICE TPC upgrade

PERSONAL RADIATION DETECTOR γ-tracer GT2-1 WITH A CdZnTe DETECTOR *

High Performance Silicon Drift Detectors

Texas active target (TexAT) detector part 1: Design and construction progress

ERDIT EUROPEAN RADIATION DETECTION AND IMAGING TECHNOLOGY PLATFORM. Prof. Christer Fröjdh, Mid Sweden University

ICS Integrated Cryocooling System

Depleted Uranium Waste Assay at AWE. T.J. Miller AWE, Aldermaston, Reading, Berkshire, England, RG7 4PR UK

ICS Integrated Cryocooling System

PM-200 Power Module Operating Instructions

APPLICATION FOR UNITED STATES PATENT. Shieldless Detector with Two-Dimensional Directionality INVENTOR:: David E. Newman DATE:: November 9, 2018

Technical Specification PILATUS 100K Detector System

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Environmental, Pollution & Security Monitoring. Radiation Protection & Nuclear Security. Radon, Thoron, Daughter Products & Radioactive Aerosols

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

PROBENCH. Manual. A&D PA Process Automation and Instruments. Automation and Drive Engineering. Editor Department Location Telephone Fax

ICS Integrated Cryocooling System

LAUNDRY MONITORING SYSTEM Model # LIM-64S

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Status Report about the TPC Detector and Module at CEPC

Preamplifier Power Supply PPS-02 user's guide

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Integrating Sphere Detectors. Wide Range of Stock Items. Individual Custom Configuration and Design. OEM Design and Production. Traceable Calibrations

Gaseous detectors. 1

Lasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors

RTM / & 01/ / RTM

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

ADVANCED SILICON DETECTORS FOR ELECTRON IMAGING & COUNTING

MODEL 4000A & 4001A ACCELEROMETER

Y-I 2 Y/DW D. D. Earl, D. B. Smith, J. A. Williams Oak Ridge National Laboratory. May 1999

Instrumental technique (MCP detectors) - Kamalesh ( )

Aging Tests of of Full Scale CMS Cathode Strip Muon Chambers

W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA Gravity Probe B Relativity Mission

Medipix PCBs and mechanics

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

Development of a variable output LED-365 irradiance standard

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

Four channel video link For low cost video transmission

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

New Generation of UV, IR and γ - ray sensors with Carbon Nano-Tubes (CNT)

List-mode Data Acquisition a New IEC Standard

Spectrum Detector, Inc.

Research Article Development and Comparison of Fiber-Optic Beta Radiation Sensors with Different Diameters of Their Sensing Probes

MEAS EMITTER ASSEMBLY ELM-4000 SERIES

Influence of New Technologies on Technical Reachback

arxiv: v1 [physics.ins-det] 1 Sep 2014

Nuclear Associates

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

Optical Time Domain Reflectometry (OTDR)

INTERNATIONAL STANDARD

GERDA Phase II Detectors and Acceptance Tests

IR detection module VPAC-1000F user's guide

MODEL AND MODEL GAS PROPORTIONAL DETECTORS. December 2016 Serial No and Succeeding Serial Numbers

Surface Concept Product Catalog 2014

RIID capability in the palm of your hand

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

A comparison of emerging gamma detector technologies for airborne. radiation monitoring

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers

Transcription:

GAMMA RAY DETECTION PROBE MODEL SO16 INSTRUCTION S MANUAL EURORAD 2, rue Ettore Bugatti F67201 ECKBOLSHEIM Tel: +33 (0)3 88 26 81 30 Fax: +33 (0)3 88 28 45 48 E-mail: info@eurorad.com - Web: www.eurorad.com Ref. : MU Edition : November 2002 1/12

TABLE OF CONTENTS MAIN CHARACTERISTICS OF THE GAMMA RAY DETECTION PROBE...3 PLANAR DETECTOR...4 HEMISPHERICAL DETECTOR...4 CSI(TL) COUPLED TO SILICON PHOTODIODE...4 PROBE SYNOPTIC...5 TECHNICAL SPECIFICATIONS...6 CABLE & CONNECTOR...7 MECHANICAL CHARACTERISTICS...8 SIGNAL PROCESSING...9 CONNECTION DIAGRAM...10 TYPICAL SPECTRA WITH CDTE DETECTOR...11 PLANAR DETECTOR 57 CO...11 HEMISPHERIC DETECTOR 137 CS...11 PLANAR DETECTOR AND CPP OR SELECTOR 137 CS...11 NOTICE OF INFORMATION...12 Ref. : MU Edition : November 2002 2/12

MAIN CHARACTERISTICS OF THE GAMMA RAY DETECTION PROBE The SO16 probe was developed for using planar or hemispherical CdTe/CdZnTe as well as scintillator detector. It incorporates the detector and the charge sensitive preamplifier. The standard probe housing (Aluminium alloy) has a cylindrical shape of 16 mm diameter and a length of 92 mm as shown on Fig. 1. 16mm detector L = 92mm Charge sensitive Preamplifier 5 contacts LEMO connector Fig. 1. Scheme of SO16 gamma-ray detection probe. This small probe is recommended for general use in both counting and spectroscopic nuclear applications in the laboratory as well as in industry. The small weight, low bias voltages and low consumption make this probe practical. The detector type, its size and quality are mounted in this probe on request. The standard probe contains the spectral quality CdTe planar detector of dimensions 5x5x2 mm 3. Ref. : MU Edition : November 2002 3/12

PLANAR DETECTOR Detector type: CdTe or CdZnTe Size: 5x5x2 mm 3 (standard) The probe including planar detector allows gamma ray detection with a good spectral resolution of 5-7 % for 57 Co. It allows frontal detection in the energy range of 20 to 200 kev. HEMISPHERICAL DETECTOR Detector type: CdTe or CdZnTe Sensitive volume: from 55 to 65 mm 3 The probe with hemispherical detector mounted inside offers nearly uniform 360 solid angle detection sensitivity. It operates without collimator and is the best suited for inspection tasks, where the direction of irradiation cannot be foreseen. The hemispherical geometry of detector ensures a good energy resolution and peak to valley ratio in a gamma energy range from 80 kev up to 1000 kev. CSI(TL) COUPLED TO SILICON PHOTODIODE The CsI(Tl) scintillator coupled to a Si diode allows to obtain good spectroscopic quality performances in the high energy range. This type of detector requires low polarisation voltage. Ref. : MU Edition : November 2002 4/12

PROBE SYNOPTIC HV 500M 1 2 1 2 100M 1.5pF OUTPUT CSP 1 2 P/Z Adjustment 1 2 1 1nF 2 1 2 DETECTOR 0.47pF Gain x10 BNC TEST INPUT 1 2 47. BNC OPTIONAL Fig. 2. Synoptic scheme of SO16 probe. Ref. : MU Edition : November 2002 5/12

TECHNICAL SPECIFICATIONS TYPE : SO16 DETECTOR: Type : CdTe detector hemispheric planar or CsI coupled to a Si photodiode Volume : from 1mm 3 to 80mm 3 PREAMPLIFIER: Type: PRS16 SMD technology charge sensitive preamplifier Noise: 1.4keV (CdTe, 0pF) Sensitivity: 250mV/MeV Si Risetime: 70ns (0pF) Fall time: 200µs Feedback network: 500MΩ / 1.5pF Output resistance: 50 Ω Supply voltage: ±12 V, ±20% Supply consuption Icc+=13 ma Icc-=9 ma Test input: 47Ω/0.47pF, Optional Ref. : MU Edition : November 2002 6/12

CABLE & CONNECTOR SUPPLY VOLTAGES Amphenol 9 contacts (DB9), male Detector BIAS voltage: high voltage BNC connector, female DB9 1 2 3 4 5 6 7 8 9 Output : BNC connector male TEST : BNC connector male (Optional) 1-2: GND 6 : 3 : 7 : 4 : +12V 8 : 5 : 9 : -12V Probe connector: Lemo 5 contacts, male 1: Bias 2: -12V 3: Output 4: +12V 5: Test Input (Optional) The standard length cable is 3 m (maximum 25m (on request)). Ref. : MU Edition : November 2002 7/12

MECHANICAL CHARACTERISTICS Size: cylindrical shape, L = 92 ± 1mm, = 16mm Material of housing : Aluminium alloy Entrance window Aluminium with 500µm thickness Fig. 3. Technical plan of SO16 probe. Ref. : MU Edition : November 2002 8/12

SIGNAL PROCESSING Common spectroscopic amplifier with gaussian / triangular shaping. Hemispherical detector: gaussian or triangular shaping amplifier Planar detector: gaussian or EURORAD model CPP (Compact Pulse Processor) or EURORAD model EUROSPECTRUM ENHANCER Ref. : MU Edition : November 2002 9/12

CONNECTION DIAGRAM NIM amplifier or CPPII BIAS VOLTAGE SHV GAUSSIAN AMPLIFIER OR CPPII BIAS DB9 POWER SUPPLY SO16 PROBE OUT IN OUT PULSE GENERATOR MCA TEST Ref. : MU Edition : November 2002 10/12

TYPICAL SPECTRA WITH CDTE DETECTOR PLANAR DETECTOR 57 CO HEMISPHERIC DETECTOR 137 CS PLANAR DETECTOR AND CPP OR SELECTOR 137 CS Ref. : MU Edition : November 2002 11/12

NOTICE OF INFORMATION (please complete in case of problem with a system) NAME : ADDRESS : TEL : FAX : PROBLEM ENCOUNTERED : Please send this notice back to : EURORAD S.A. Mme KAZANDJIAN 2, rue Ettore Bugatti F-67201 ECKBOLSHEIM FRANCE Tel : +33 (0)3 88 26 81 30 Fax : +33 (0)3 88 28 45 48 Ref. : MU Edition : November 2002 12/12