PRODUCT NUMBER: Rd40 Aluminium Canister AXP3

Similar documents
PRODUCT NUMBER: RD40 Plastic Filters AXP3 XL

PRODUCT NUMBER: Tuff Cut Latex

PRODUCT NUMBER: Honeywell SuperOne FFP2 NR

PRODUCT NUMBER: Quiet (Corded) Easy handling and better fit

Overview. Features & Benefits

PRODUCT NUMBER: QB3HYG Semi-Aural Banded

PRODUCT NUMBER: N L

PRODUCT NUMBER: AirSoft (Red Vinyl Cord)

PRODUCT NUMBER: SP1000 Safety Eyewear, Black Frame, ClearLens

PRODUCT NUMBER: Smartfit Detectable

PRODUCT NUMBER: SmartFit (Corded)

PRODUCT NUMBER: Max LS-500 Refill

PRODUCT NUMBER: Max (Uncorded)

PRODUCT NUMBER: Laser Lite Single-Use (Corded)

PRODUCT NUMBER: Laser Trak Single-Use Detectable Earplug

PRODUCT NUMBER: Honeywell ICOM

PRODUCT NUMBER: FirePro OVER-PANTS

PRODUCT NUMBER: FlamePro1 JACKET

PRODUCT NUMBER: FirePro PARKA

PRODUCT NUMBER: Honeywell Adaptec. Frame Size : Wide Frame Color: Blue/Gray Lens Tint: Clear

PRODUCT NUMBER: SmartFit (Corded)

PRODUCT NUMBER: Viking V1 Multiple-Position Earmuff

PRODUCT NUMBER: Leightning L0Ns Neckband Earmuff

PRODUCT NUMBER: Clarity C3 Headband Earmuff

PRODUCT NUMBER: Thunder T3s Headband Earmuff

PRODUCT NUMBER: Bilsom AM/FM Radio Hi-Vis Earmuff

PRODUCT NUMBER: Leightning L3s Headband Earmuff

CBRN filtration systems

PRODUCT NUMBER: Honeywell Turboshield Headgear

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Multipoint temperature sensor

Powered Air Purifying Respirator (PAPR) SAFETY, COMFORT, FLEXIBILITY. Compact Air 200 Series PAPR No Worry, No Guesswork

Product Numbers & Ordering Information

3M Safety Solutions - OH&ESD. 3M 3000 Series Half Mask Respirators. Light. face, on your. light. on your budget. The Power to Protect Your World

Page 1 of 5. Product Numbers & Ordering Information. Product Numbers. Details

OPTIBAR DP 7060 Supplementary Instructions

HazLoc Essential Guides:

Operating Instructions

BUSINESS PLAN CEN/TC 79 RESPIRATORY PROTECTIVE DEVICES EXECUTIVE SUMMARY

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Dräger X-am 2500 Multi-Gas Detection

Operating instructions

Environmental Product Declaration

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

The PPE Directive and the PPE Regulation

Adsorption dryers PDAD

Product Family Honeywell V-Maxx

Firetect C. Fire protective products: Fire protective board

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

- SAFETY MANUAL - DAMPERS

FDOOT221, FDO221, FDT221

Honeywell Safety Products

BUSINESS PLAN. CEN/TC 137 Assessment of workplace exposure to chemical and biological agents EXECUTIVE SUMMARY

THE MEDIX Actineb. Technical Specifications. % Particles < 5 um 75% * Class II BF. Intermittent (use for 60 Type Rating

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

REFLOW OVEN FT01 Version REFLOW OVEN FT01. (Article number F31105) User s Manual

TRASCO ATEX Couplings

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

½ Monitored Pneumatic Valve Patented Technology

The Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives

Dräger Catalytic Ex-Sensors DrägerSensors

Lead them to safety. Honeywell Safety Products. Honeywell can help you build an enduring culture of safety.

FDOOT241-A9-Ex Multisensor fire detector

Ariazone 601HD Refrigerant Recovery&Recycling unit

Regulation (EC) 1272/2008 on Classification, labelling and packaging. (CLP Regulation) DG Environment

Part No KEMPER Filter-Master XL

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

The New PPE Regulation (EU) 2016/425

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

INSTALLATION AND OPERATION MANUAL

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

HazLoc Essential Guides:

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

½ Monitored Pneumatic Valves On Series Ported Manifold

METHODOLOGY FOR TESTING PERSONAL

Operating Instructions

Dryer Systems. Breathing Air Units

DECORATIVE WALLCOVERINGS - ROLL AND PANEL FORM PRODUCTS IRISH STANDARD I.S. EN 15102:2007. Price Code. Údarás um Chaighdeáin Náisiúnta na héireann

Part 2-55: Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

FDOOT241-9, FDOOT241-A, FDO241, FDT241

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

Eaton Contamination Control Products FT1555-BM bench mount capping machine operating instructions

Valve Manufacturers Association of America

Safe Operation Manual. Honeywell IQ Force Gas Detector

EUROPUMP ATEX Guideline Part II

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Energy Saving Refrigerated Compressed Air Dryers DES Series 90 to 675 scfm (153 to 1148 nm 3 /h)

Certification Supplement Manual

Dräger X-am 5000 Multi-Gas Detection

KEVA 20, 30 & 45 ATEX ELECTRIC VACUUM CLEANER OPERATOR MANUAL

Assessment of plans. DI Thomas Knoll Knoll Planung & Beratung Vienna, Austria

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Quick Reference Guide to Cabinet types

Transcription:

Europe / Africa PRODUCT NUMBER: 1785018 Rd40 Aluminium Canister AXP3 The AXP3 canister is part of the broad choice of canisters offered to protect against many hazardous gases, vapors and/or particulates in many applications. The Honeywell range provides high quality and a cost-effective protection. The canisters of RD40 Honeywell range are tested against the European standards EN14387 and EN148 and/or EN143. Overview Reference Number 1785018 Product Type Respiratory Protection Range Reusable APR Brand Honeywell Brand formerly known as FERNEZ by Willson Industry Industry Product Use For use with full-face mask equipped with an Rd40 connector For protection against organic gases and vapours with a boiling point below 65 C, solid and liquid particles. s & Benefits Aluminium casing allows easy detection of damages caused by external shocks providing extra safety. Performance requirements for gas and particles significantly above standard for excellent filtration efficiency over extensive period of time. Canister made of high-grade charcoal, additionally treated for an optimal gas absorption. Specific canister structure for low breathing resistance and more comfort for the user. Low profile so as not to obstruct the field of vision Page 1 Of 3 Honeywell International Inc.

Aluminium Specific Filter 450 AX P3-1785018 Individually packed. Technical Description Filters Cartridges Standard - RD40 connection in compliance with the EN148 - Particle filters efficiency (EN143) - EN14387 (Gas/vapours and combined filters for respiratory with negative pressure)- Conformed to the requirements of the European Community Directive 89/686/EEC (Personnal Protective Equipment), belongs to the EC Category III and is CE marked, followed by the identification of the certification body (0194), which assure the quality control (according to the article 11B). Protection Type Combination Connection Type RD40 Protection Level P3 Class 3 Material Special aluminium alloy with PE cover High activated charcoal 106mm Certifications E.C. Declaration of Conformity EC Category PPE 3 Quality Assurance ISO 9001 / 2000 EC Certificate Number 0070-003-079-06-96-0118 Ext. 01-02-00 EC Attestation EC Attestation EC Attestation Number 0070-003-079-06-96-0118 Ext. 01-02-00 Declaration of conformity INRS - 1785018 http://www.honeywellsafety.com/supplementary/documents_and_downloads/secured/pic_sku_- _certificates/4294989390/1033.aspx Literature & Documents 1785018 AXP3 tested substances http://www.honeywellsafety.com/supplementary/documents_and_downloads/respiratory_protection /reusable_respirators/4294974289/1033.aspx Additional Information User Manual User Manual Filters Maintenance Page 2 Of 3 Honeywell International Inc.

Life Cycle Depends on absorption capacity, concentration of contaminant and user breathing Storage Information 4 years after date of manufacturing - Store the filters in a cool, dry, location with the caps attached - The maximum permissible storage period is specified on the filter - Storage temperature range: -20 C / +50 C - Maximum humidity during storage: 80% Care Instructions Controls before use Users must Ensure that the level of protection offered by the respirator is sufficient for the type and concentration of contaminant(s) in the work area Respect the shelf life figuring on the filter Check the seal points Limitations of use Aluminium Specific Filter 450 AX P3-1785018 Limitations of use For use only by trained and qualified personal Do not use where the oxygen level or the atmosphere is less than 17% If a user identifies the break through of the canister by the smell or taste of a gas, the canister must be replaced immediately If the breathing resistance of the canister increased significantly, it must be changed. Particular cautions have to be taken in Atex environments Filter with a mass over 300 g may not be used fitted directly onto half-masks AX and AXP3 canister are single use only. They must be replaced after each shift. Disposal Canister must be disposed in accordance with the local waste disposal regulations Packaging EAN Code 7312557850186 Packaging Specs Individual Box 18 x 10 x 10 Packaging Specs Stocker Box 59 x 23 x 23 Unit of Measure CM Quantity per Box/Pack/Case 1 unit of 380 gr Quantity per Carton 50 units for a gross weight 19 kg Honeywell International Inc. Page 3 Of 3 Honeywell International Inc.

E.C. Declaration of Conformity The manufacturer or its legal representative supplier in the European Community: Honeywell Safety Products Europe Declares that the Personal Protective Equipment described here after conforms to the provisions of the European Council Directive 89/686/CEE: Designation: Rd40 Aluminium Canister AXP3 Reference: 1785018 Standard(s): EN371 This PPE is the object of the below EC examination certificate n : 0070-003-079-06-96-0118 Ext. 01-02-00 Delivered by: INRS Avenue de Bourgogne BP 27 54501 Vandoeuvre Cedex France Drawn up in Villers-Cotterêts, on the 02/05/2016 By: Eric PUILLE Division: Respiratory Protection Zl Paris Nord II 33, rue des Vanesses BP 50288 95958 Roissy CDG France Tel: +33 (0) 49 90 79 79 Fax: +33 (0)1 49 90 79 80 www.honeywellsafety.com

Part # Number 1785018 Rd40 Aluminium Canister AXP3 Gases Tested Conditions and results - Methoxymethane C2H6O 50 min. - Isobutane C4H10 50 min. - The concentration of the test gas is 0.05% vol. for methoxymethane and 0.25% vol. for isobutane - The tested air flow is 30 litres per minute - Minimum duration required before "breakthrough" : Aerosols tested Conditions and results * Paraffin oil for liquid particulates - The tested air flow is 95 litres per minute * Sodium chloride for solid particulates - The aerosol penetration for the test must be less than : *0.05% for sodium chloride * 0.05% for paraffin oil - Breathing resistance less than: * 2.2 mbar at 30 l/min * 8.2 mbar at 95l/min.