Boilers REVIEWED (REV): FURNISH AS NOTED (FN): REVISE AND RESUBMIT (RR): REJECTED (R): SUBMIT SPECIFIED ITEM: SUBMITTAL NOT REQUIRED AND NOT REVIEWED:

Similar documents
Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Originators of the Flexible Water Tube design

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Date: Project #: Engineer: Prepared By: Bid Date:

Revitalize Building Mechanical Systems (4619)

Section B1. Flexible Watertube Boilers TABLE OF CONTENTS

HCLEARFIRE. High-efficiency, modular steam boiler HP

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

HIGH EFFICIENCY COMMERCIAL BOILERS

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

23 11/32 [593] Ø8 AIR INLET [203] 6 5/8 [168] 44 3/4 [1137] TOP VIEW ASUB-31 REV. B 38 11/16 [983] 3 NPT BOILER OUTLET WIRING CONNECTIONS 1 NPT 1 NPT

Project Name: Location: Engineer: Contractor: I. GENERAL

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

FUEL-FIRED VERTICAL TUBELESS BOILERS

Power Flame Incorporated

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

FXLF-9. High Efficiency Water Heaters and Boilers

Power Flame Incorporated

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Fuel-Fired Vertical Tubeless Boilers

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

SAMPLE SPECIFICATIONS

DIVISION FINNED WATER-TUBE WATER HEATERS

Raptor 320HB & 399HB Submittal Sheet

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Boiler & Water Heater

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

G515/7 Cast Iron Boiler

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

ClearFire - Hydronic Startup Report

G315/6 Cast Iron Boiler

DIVISION FINNED WATER-TUBE BOILERS

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

SECTION WATER-TUBE BOILERS

FINNED WATER-TUBE POOL HEATERS

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

G315/5 Cast Iron Boiler

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

SECTION HEATING BOILERS

Triton Series High Efficiency Boiler

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

G615/11 Cast Iron Boiler

Burner Comparisons. Typical Competitor s Burner

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

SERIES 19A. mith PRESSURIZED WET BASE

CONDENSING HIGH EFFICIENCY BOILERS

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

FINNED WATER-TUBE POOL HEATERS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

WATER-TUBE POOL HEATERS

Williams & Davis Boilers

FLEXCORE SERIES MASTERSPEC

Suggested Specifications Prestige Excellence 110

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

SB615/310 Stainless Steel Condensing Boiler

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

CLM FORCED DRAFT STEAM BOILER

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

High Efficiency Commercial Gas Water Heaters

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

GB Condensing Gas Boiler

WATER-TUBE POOL HEATERS

Proudly assembled in U.S.A

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water.

CSD-1 COMMERCIAL BOILER CONTROLS

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

Transcription:

PROJECT NAME: Westlake Lee Burneson Middle School SUBMITTAL NO: 235216-1 OE PROJECT NO.: J20090123.000 MANUFACTURER: Bryan Boilers/Gardiner Trane DESCRIPTION: Boilers SPEC SECTION: 235216 DATE RECEIVED 2/6/12 DATE DUE 2/13/12 1300 East 9th Street, # 1500 441 Wolf Ledges Pkwy., #300 Cleveland, OH 44114 Akron, OH 44311 t: 216-861-2020 t: 330-535-3132 f: 216-861 3329 f: 330-535-3195 osborn-eng.com This information is only for the general conformance with the design concept and the information given in the Construction Documents. Comments made on the shop drawings during this review do not relieve the contractor from compliance with the requirements of the plans and specifications and applicable laws, codes and regulations. Review of a specific item shall not include review of an assembly of which the item is a component. The Contractor is responsible for: dimensions to be confirmed and correlated at the job site; information that pertains solely to the fabrication processes or to the means, methods, techniques, sequences and procedures of construction; coordination of the Work with that of all other trades and performing Work in a safe and satisfactory matter. OSBORN DISTRIBUTION Discipline Reviewer Review Complete Date Action PX Architectural: Structural: Civil: Mechanical: BGK 2/22/2012 FN Electrical: Technology: Other: 1. px in the check box indicates the Primary Reviewer; x in the check box indicates additional Reviewer(s). 2. The Primary Reviewer should review the submittal first. 3. The Primary Reviewer is responsible for coordinating with the other disciplines. REVIEWED (REV): FURNISH AS NOTED (FN): REVISE AND RESUBMIT (RR): REJECTED (R): SUBMIT SPECIFIED ITEM: SUBMITTAL NOT REQUIRED AND NOT REVIEWED: REVIEWED BY: BGK DATE: 2/22/12 Comments: A gas booster pump shall be issued in future bulletin for the Middle School to meet Bryan boiler gas pressure requirement of 14 W.C. Bryan/Gardiner Trane to provide 1 or 2 gas pressure regulator(s) to reduce gas pressure to 7 for the rest of the building. Turner and installing contractor to coordinate combustion air, flue, and equipment pad size and location differences, and piping connection modifications from the basis of design. Page 1 of 1 Submittal Review Form - Standard

Middle School DC 1/3012 235216-1

Submittal Data Model TF200 Serial Burner Type Burner Fuel FDG-LX Natural Gas Order 5110456 Job Sales Agent Contractor Customer Engineer Architect Lee Burnesen Middle School Gardiner Trane Gardiner Trane Osborn Engineering MKC Associates TO THE INSTALLER: Read contents carefully before uncrating. After completing installation, hang this information near the boiler(s) for future reference. Bryan Steam LLC 783 North Chili Avenue, Peru Indiana 46970 Phone 765-473-6651 12/15/2011 10:59 AM E-Mail: inquiry@bryansteam.com Internet: www.bryanboilers.com

Submittal 5110456 15 December 2011 Triple-Flex Job Name Contractor Sales Agent Engineer Architect Lee Burnesen Middle School Gardiner Trane #4275 Osborn Engineering MKC Associates Model Max Input Max Output Boiler HP Fuel Gas Pressure Firing System TF200 2000 MBH 1800 MBH 54 HP Natural Gas 14 IWC 2 PSI Modulation Quantity Design Pressure Relief Valve Set Approval Codes Control Circuit Burner Circuit 2 160 PSI 60 PSI UL/FM/CSD1 120/1/60/2.5 230/1/60/7 Equipment Furnished Standard Trim ASME Construction ASME Relief Valve Size (1-1/4" x 1-1/2") & Qty. (2) Heavy Gauge Steel Jacket High Limit Control (Manual Reset) Lifting Lugs National Board Stamped Operating Control Probe Type Low Water Cutoff (Manual Reset) 2" OD Pressure Gauge 2" OD Thermometer Stepdown Transformer Primary Fuel Air Ratio Valve Auxiliary Gas Valve Pilot Gas Pressure Regulator (2) Low Gas Pressure Switches (3) High Gas Pressure Switches Pilot Gas Valve FS4-3 Flow Switch Cleveland Air Flow Switch UV Scanner R7910A Hydro Reset Control S7999B System Display Module (2) Supply/Stack Sensors (2) Plugged Test Cocks Dual Manual Gas Shutoff Valves Optional Features Combustion Air Filter Housing w/flange Condensate Neutralizer Kit Audible Alarm Agency Nameplate Bryan Steam LLC 783 North Chili Avenue, Peru Indiana 46970 Phone 765-473-6651 12/15/2011 10:59 AM

Submittal 5110456 Equipment List Order Date Job Name Sales Agent Contractor 12/13/2011 Lee Burnesen Middle School Gardiner Trane #4275 Customer PO State/Province Engineer Architect WILL ADVISE OH Osborn Engineering MKC Associates Model ASME Design Pressure TF200 Section IV 160 PSI Quantity Altitude Design Temp 2 700 Ft 210 F Max Input Min Input Heating Surface Relief Valve Set Design Capacity 2000 MBH 400 MBH 678 Ft² 60 PSI 6780 LB/HR Max Output Min Output Boiler HP Actual Capacity 1800 MBH 360 MBH 54 HP 9192 LB/HR Burner Fuel Natural Gas Max Supply Press 2 PSI Min Supply Press 14 IWC Gas Content 1000 BTU Per Ft³ Manifold Press Max Input Min Input 4 In. WC 2000 SCFH 400 SCFH Control Circuit Burner Circuit National Board Approval Codes 120/1/60/2.5 230/1/60/7 Yes UL/FM/CSD1 Wiring Diagram 1 5110456W Wiring Diagram 2 Bryan Steam LLC 783 North Chili Avenue, Peru Indiana 46970 Phone 765-473-6651 12/15/2011 10:59 AM

Submittal 5110456 Equipment List Order Date Job Name Sales Agent Contractor 12/13/2011 Lee Burnesen Middle School Gardiner Trane #4275 Customer PO State/Province Engineer Architect WILL ADVISE OH Osborn Engineering MKC Associates BO Ship Unit Ext Field PartNo Description Burner Components 1 2 0 22051 Cleveland Air Switch, 18469AFS 1 2 0 P20005 Ignition Electrode Crown #15340 1 2 0 P20011 Comb Air Blower, EBM Pabst #G3G250GN1701 1 2 0 P20016 Observation Port, C-ALL-FP Observ. Front Pilot 1 2 0 P20022 R7910A-1027 Hydro Control, Honeywell, 120 VAC 1 2 0 P20118 Thermal Fuse Assy, Devale C-36900252, 425 F, 25 Control Panel/Box Trim 1 2 0 27890 C7027A-1049 UV Scanner 1 2 0 P20006 Oslo Rocker Switch C-RTP-2A-9-M9 On/Off Style 1 2 0 P20014 Oslo Push Button SPM1A-1-M9 1 2 0 P20023 S7999B-1026 System Display Honeywell SOLA 1 2 0 P20053 Fuseblock, 3-Pole for Type CC Fuses, Box Lug - 1 2 0 P20062 TFMR,CC,208-430-460V Pri/120V Sec C-H 1 2 0 P20117 Transformer, 120/24V Basler #BE121640 GDD 2 4 0 P20124 Fuse, 7 Amp, LP-CC-7 2 4 0 P20126 Fuse, 2.5 Amp, LP-CC-2-1/2 1 2 0 P20128 Fuse, 3.5 Amp, LP-CC-3-1/2 1 2 0 P40199 Alarm Light Assembly, TF Boilers, Red 1 2 0 P40200 Power Light Assembly, TF Boilers, Clear 1 2 0 P40201 Fuel Light Assembly, TF Boilers, Yellow 1 2 0 P40202 Enable Light Assembly, TF Boilers, Green Insp Check Crate Carton Controls Trim Draft Control Gas Train Trim 1 2 0 28108 121371A Well, 1/2" Short 1 2 0 28301 FS4-3 Flow Switch 1 2 0 28344.3 550SV Manual Reset LWCO w/push to Test 2 4 0 P20029 Supply/Stack Sensor Honeywell 50001464-006 6" 1 2 1 [o] P40188 Air Filter Extension Housing Assembly 1 2 0 22122 Siemens SKP55.013U1 Valve Actuator 2 4 1 26818 2" Manual Shutoff Valve 2 4 0 28170.1 LGP-G M/R Sw, 1-20" 3 6 0 28173.1 HGP-G M/R Sw, 2-20" 2 4 0 39190 Plugged Test Cock & Tee 1 2 0 P20007 Double Valve Body, 2" Siemens #VGD20.503U 1 2 0 P20009 Actuator, SSOV Siemens #SKP15.013U1 1 2 0 P20018 Gas Valve, 2" NPT, #76100 Hauck Bryan Steam LLC 783 North Chili Avenue, Peru Indiana 46970 Phone 765-473-6651 12/15/2011 10:59 AM

Submittal 5110456 Equipment List Order Date Job Name Sales Agent Contractor 12/13/2011 Lee Burnesen Middle School Gardiner Trane #4275 Customer PO State/Province Engineer Architect WILL ADVISE OH Osborn Engineering MKC Associates BO Ship Unit Ext Field PartNo Description Other 1 2 1 [o] P40189 Neutralizer Assembly Triple Flex Boilers Pilot Train Trim 1 2 0 26601 V4046C-1021 Pilot Valve 5 10 0 26802 1/4" Manual Shutoff Valve 1 2 0 26863 325-3 Pilot Reg, 3/8" 1 2 0 28500 1092-F Ign Transf Insp Check Crate Carton Vessel Trim 2 4 0 262322 10-616-12, 60# SRV, 1-1/4" x 1-1/2" 1 2 0 P20037 Thermometer, 2" OD Remote Bulb, 0-250F 1 2 0 P20096 Press Gauge, 0-200#, 2" OD, Panel Mount, U- Product Serial National Board Product UL/CSA Burner Serial Burner UL/CSA Stock Room Check By Final Inspection By Bryan Steam LLC 783 North Chili Avenue, Peru Indiana 46970 Phone 765-473-6651 12/15/2011 10:59 AM

Form No. 8700 Triple-FlexTM Ultra-High Efficiency Condensing Hot Water Boilers Minimum 90% Thermal Efficiency at 160 F Return with 20 Rise Patent Pending Originators of the Flexible Water Tube design TM TRIPLE-FLEX

Low maintenance costs, high operating efficiency deliver substantial return on investment All Bryan TF Series boilers offer these operating and performance features Guaranteed efficiency The breakthrough in ultra-high efficiency condensing water tube boiler design that produced the TF Series provides operating thermal efficiency so reliable, we guarantee it to be 90% at 160 F return with 20 rise. The Bryan Flexible Tube Flexible tubes are easily removable and replaceable, without welding or rolling, eliminating long, expensive downtime should repairs ever be required. Water cooled furnace The configuration of the water tubes provide a water cooled combustion chamber. Optimal spacing of the tubes create high velocity flue gas travel for maximum heat transfer. Compact design, minimum floor space Our compact water tube design delivers over nine square feet of heating surface area per HP. Needing only 27" for tube removal, and on only one side of the boiler, the TF Series boiler occupies very little space in the boiler room. Bryan s exclusive reverse construction feature brings maximum design flexibility to the engineer. The heart of ultra-high efficiency 1. The unique three pass design in the combustion and convection sections of the boiler allow for maximum fireside heat transfer. 2. Gases continue to the combustion air preheater to recover free heat that would otherwise be wasted out the stack. 3. Resulting stack temperatures are less than half of other boilers. Bryan Triple-Flex TM Series Boilers Standard and Optional Equipment STANDARD EQUIPMENT FURNISHED Water Boiler Thermometer and pressure gauge, safety relief valve, operator control. High limit control and probe type low water cutoff both with manual reset. Sub 30 ppm Low NOx. ASME Section IV boiler, 210 F./160# design with UL/C-UL Listing. CSD-1, FM & GE-GAP specifications. Boiler Control Center The control center will be provided with "SOLA" control, remote reading temperature and pressure gauges, indicating lights power, call for heat, fuel on and failure, a onoff switch and control reset. All controls including control circuit transformer will be installed and wired. Gas Equipment Burner firing shut-off valve, automatic operating gas valve, safety gas valve. High and low gas pressure switches, air and water flow switches, pilot solenoid valve, electric ignition, main manual gas shut-off valve, gas pressure regulating actuator, pilot shut-off valve, pilot gas pressure regulator. Based on natural gas 1,000 BTU/CF supplied at 14" W.C. minimum 2 PSIG maximum. OPTIONAL EQUIPMENT 1. Auxiliary probe type low water cutoff 2. Auxiliary float type water cutoff (field mounted) 3. Alarm buzzer 4. IRI like specifications

1,500,000 to 3,000,000 BTUH Natural Gas Fired Triple-Flex TM Boilers Quality Construction Features Over nine square feet of heating surface per BHP. Air to air heat exchanger housing constructed of heavy gauge stainless steel for exceptional durability. Variable speed blower provides preheated combustion air to the burner while saving energy over other designs. Heavy gauge stainless steel combustion section is lined with high temperature ceramic fiber and insulation for optimal transfer of burner energy. Easy single side access to tubes and burner. Bryan's forced draft hybrid metal fiber type burner. Efficient combustion of gas with quiet operation. Jacket panels are attractive and rust-resistant with durable powder coat finish, air insulated to insure exceptionally cool outer jacket surface. Easy access for service and inspection. Convection section of boiler is heavy gauge stainless steel with easy access for inspection. Bryan stainless steel bent water tubes are flexible, individually replaceable without welding or rolling. Never more than two tube configurations. Electrical box: all controls installed and connected to terminal strip with access points for interface to EMS/BMS. Honeywell SOLA Exceptional system management provided with the Honeywell SOLA Hydronic Control. Touch screen display technology allows for complete monitoring and control of burner and boiler control points. The SOLA control is equipped with ModBus communications protocol for interface with EMS/BMS and is configurable to accept 4-20 Ma signal for temperature setpoint reset or firing rate. Outputs include flue gas and supply water temperature along with system pump control. Internal lead/lag function will stage up to 8 boilers for precise temperature control of the heating loop. Thermal Efficiency % Efficiencies up to 99% will be delivered with lower temperature design systems. TF300 Thermal Efficiency 100 99 100% Input 98 20% Input 97 96 95 94 93 92 91 90 89 60 80 100 120 140 160 180 Return Water Temperature (20 F. Rise)

Bryan Triple-Flex TM Series Gas Fired Flexible Tube Boilers D A I B Ø H J PLAN VIEW F C L E G REAR VIEW LEFT SIDE VIEW FRONT VIEW BOILER DIMENSIONS in inches (cm) A B C D E* F G H I J L BOILER Length Width Height Min. Tube Floor to MODEL Of Outside Over Overall Gas Train Supply Return Flue Flue Removal Flow NUMBER Jacket Jacket Jacket Length Connection Nozzle Nozzle Size Location Clearance Nozzle 122 7 /8 34 3 /4 75 1 /4 128 3 /4 2 NPT 3 FLG 3 FLG 8 100 13 /16 27 67 3 /4 TF 150 (312.1) (88.3) (191.1) (327.02) (5.1) (7.6) (7.6) (20.3) (256.06) (68.6) (172.1) TF 200 TF 250 TF 300 122 7 /8 34 3 /4 75 1 /4 128 3 /4 2 NPT 3 FLG 3 FLG 8 100 13 /16 27 67 3 /4 (312.1) (88.3) (191.1) (327.02) (5.1) (7.6) (7.6) (20.3) (256.06) (68.6) (172.1) 144 1 /4 34 3 /4 75 1 /4 150 1 /8 2 NPT 3 FLG 3 FLG 8 122 1 /4 27 67 3 /4 (366.4) (88.3) (191.1) (381.3) (5.1) (7.6) (7.6) (20.3) (310.5) (68.6) (172.1) 144 1 /4 34 3 /4 75 1 /4 150 1 /8 2 NPT 3 FLG 3 FLG 8 122 1 /4 27 67 3 /4 (366.4) (88.3) (191.1) (381.3) (5.1) (7.6) (7.6) (20.3) (310.5) (68.6) (172.1) NOTE: *Gas train connection may vary depending on job specifications and conditions. Dimensions and specifications are subject to change without notice. Consult factory for certified dimensions. Bryan TF Series Boiler Specifications BOILER MODEL INPUT OUTPUT@ 90% OUTPUT@ 98% HEATING APPROX. MBH MIN. EFFICIENCY with 160 F. Return* EFFICIENCY with 80 F. Return* SURFACE SHIP (KW) MBH (KW) HP (KW) MBH (KW) HP (KW) SQ. FT. (M 2 ) LBS. (KG) TF 150 1,500 (439) 1,350 (395) 40 (395) 1470 (430) 44 (430) 678 (63) 3,545 (1,608) TF 200 2,000 (586) 1,800 (527) 54 (527) 1960 (574) 59 (578) 678 (63) 3,545 (1,608) TF 250 2,500 (732) 2,250 (659) 67 (659) 2450 (717) 73 (716) 782 (72) 4,080 (1,850) TF 300 3,000 (879) 2,700 (791) 81 (790) 2940 (861) 98 (959) 782 (72) 4,080 (1,850) NOTE: *Output and horsepower based on 20 degree F. Delta T and maximum firing rate. Bryan Steam LLC Leaders Since 1916 783 N. Chili Ave., Peru, Indiana 46970 U.S.A. Phone:765-473-6651 Internet:www.bryanboilers.com Fax: 765-473-3074 E-mail:inquiry@bryansteam.com Form No. 8700 2009 Bryan Steam LLC Printed in USA 109-9810