P P Gas Fireplace. P See Thru

Similar documents
Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

City Series CV40E Gas Fireplace

City Series CB40E Gas Fireplace

City Series CC40RE Gas Fireplace

PTO50 Outdoor Decorative Fireplace

Manual. Owners & Installation. Zero Clearance Room Sealed Gas Fireplace PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

Manual. Owners & Installation. Panorama PG121/PG131 Gas Fireplace PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

Manual. PG33 Gas Inbuilt. Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. Models: PG33-NG PG33-LPG

Greenfire GF950L Gas Fireplace

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

PG33 Gas Inbuilt. Manual

Panorama PG33 Gas Inbuilt


P95-3 Zero Clearance Direct Vent Gas Fireplace Owners & Installation Manual

Manual. P36D Gas Log Fireplace. Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. Models: P36D-NG2 P36D-LPG2

Panorama PG36 Gas Log Fireplace. Manual

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

Greenfire GF1500L Gas Fireplace

Regency Gem54 Gas Fireplace

P121 / P121LC / P121RC / P131 Zero Clearance Direct Vent Gas Fireplace. Owners & Installation Manual.

Regency Gem54 Gas Fireplace

Greenfire GF1500LST Gas Fireplace

MODELS: H25-NG Natural Gas H25-LP Propane FOR YOUR SAFETY

MODELS: P33-NG4 Natural Gas P33-LP4 Propane

BDM Direct Vent systems are for use with direct vent gas fired appliances.

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

MODELS: P40-NG1 Natural Gas P40-LP1 Propane

Panorama P33-10 Zero Clearance Direct Vent Gas Fireplace

Panorama P36 Zero Clearance Direct Vent Gas Fireplace

Regency Horizon HZ54 Gas Fireplace

LIBERTY L900-1 Gas Fireplace

DANGER HOT GLASS WILL CAUSE BURNS. DANGER. WDV See-thru Direct Vent Gas Fireplace Installation and Operating Instructions

Direct Vent Zero Clearance Gas Fireplace Heater Models: DV1000N/P, DV1200N/P, DV1400N/P

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Regency Horizon HZ54 Gas Fireplace

SERRANO POSITIVE PRESSURE GAS FIREPLACE

TAMARRON HEAT RECIRCULATIVE GAS FIREPLACE

PelletVent Multi-fuel venting system. UL 641.

DANGER. Installation and Operation Manual CARLTON-39

Manual. P36 Gas Inbuilt Calais / Grenada. Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. Models: P36-NG3 P36-LPG3

INSTALLATION INSTRUCTIONS

Intrigue 42 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL: UF0100 GAS FIRED DIRECT VENT FIREPLACE S/N AND UP

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

GAS DIRECT VENT FIREPLACE WITH HEARTHGLO SEALED COMBUSTION SYSTEM Model DXV-60 (SHOWN WITH OPTIONAL PRAIRIE FRONT and OVERLAY)

USERS INSTALLATION OPERATION and MAINTENANCE MANUAL. Installer: Please leave this manual with the appliance owner for future reference

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

ProBuilder 42 & 54 Linear GSB2

Manual FOR YOUR SAFETY

WDV See-thru Wideview Direct Vent Gas Fireplace

Owner s Manual Installation and Operation

WDV Wideview Direct Vent Gas Fireplace

Regency Bellavista B41XTE Gas Fireplace

864 See Through GS2 Fireplace

ZC Kit AGP Pellet Insert

Manual FOR YOUR SAFETY

Multi-Sided Direct Vent Decorative Gas Fireplace

MODELS: P33-NG5 Natural Gas P33-LP5 Propane

For models purchased after 4/16/15, please see addendum.

Infinite Series Installation Instructions

Regency P33 Sunrise Gas Fireplace

M-27 INSTALLATION & OPERATING INSTRUCTIONS MANUAL DOCUMENT NO. M

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

BLDV SERIES DIRECT VENT GAS FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONS

WARNING LOFT FIREPLACE. Direct vent Gas Fireplace. Model series: CONSUMER: Retain this manual for future reference.

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SERIES:

MENDOTA GAS DIRECT VENT FIREPLACE Model DXV-45 SHOWN WITH OPTIONAL PRAIRIE DOOR KIT AND OVERLAY

MENDOTA GAS DIRECT VENT FIREPLACE WITH HEARTHGLO SEALED COMBUSTION SYSTEM Model DXV-35 TIMBER FIRE with Direct Rear Vent Option

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL DIRECT VENT ZERO CLEARANCE GAS FIREPLACE MODEL SERIES:

864 See Through GS2 Fireplace (with screen)

BAYPORT 41 & BAYPORT 36

Model 530SAN Model 530SAP Direct Vent Gas Fireplace Heater (with Logs or Coals)

NOTICE CAUTION DANGER DANGER WARNING

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Panorama P121 / P131 Zero Clearance Direct Vent Gas Fireplace

Installation and Operation Manual

WARNING INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Designer Series Direct Vent Gas Fireplace

DANGER BAYPORT-36-LOG BAYPORT-36-BW INSTALLATION AND OPERATION MANUAL

Panorama P33-10 Zero Clearance Direct Vent Gas Fireplace

Infinite Series. Installation Instructions

BAYPORT 41 & BAYPORT 36

Regency Horizon HZ30E Gas Fireplace

WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.

Installation Instructions

564 HO NB GSR2 (with screen) Installation Manual

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SERIES:

Panorama P121 / P131 Zero Clearance Direct Vent Gas Fireplace

564 Cleanface (SS) GSR2 Fireplace

INSTALLATION BOOKLET. 530 Direct Vent GAS FIREPLACE HEATER

DANGER. Installation and Operation Manual SPRINGFIELD 36

2012 INTERNATIONAL FUEL GAS CODE VENTS

DIRECT-VENT GAS FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

6015 HO GSR2 (with screen) Installation Manual

6015 HO GSR2 Fireplace (Aust) Direct Vent Fireplace Natural Gas or Propane Vent Horizontally or Vertically Standard Residential Mobile Home Approved

864 TRV GS2 (with screen) Installation Manual

Transcription:

P121-10 - P131-10 Gas Fireplace Model P121/P131-NG10 P121/P131-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa) Manifold Pressure - Low 1.1 W.C. (0.27 kpa) 2.9 W.C. (0.72 kpa) Orifice Size #31 DMS #50 DMS Minimum Input 20,500 BTU/h (6.01 kw) 20,600 BTU/h (6.04 kw) Maximum Input 40,000 BTU/h (11.72 kw) 39,000 BTU/h (11.43 kw) Vent Sizing 4 Inner / 6-5/8 Outer 4 Inner / 6-5/8 Outer Approved Venting Systems Flex Vent Systems: Rigid Pipe Vent Systems: FPI AstroCap Flex Vent Simpson Direct Vent Pro American Metal Products Amerivent Direct Security Secure Vent Selkirk Direct-Temp Metal-Fab Sure Seal ICC Excel Direct P121-10 See Thru Please refer Exterior Vent Terminations for additional guidelines on vent locations.

P131-10 Pier Please refer Exterior Vent Terminations for additional guidelines on vent locations.

1) For ease of installation, frame your fireplace after it is positioned and the vent system is installed. Remember to install the top standoffs. See the "Unit Assembly Prior to Installation" section. Use 2x4's and frame to local building codes. CAUTION: Verify your fireplace dimensions, framing methods and finished wall facing details before framing. Determine the total thickness of facing material - drywall plus ceramic tiles, slate, etc. Allow the finish surface to be flush with the front or side of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick. 2) When locating your appliance on an exterior wall or in a chase, apply a vapour barrier and drywall, as per local building codes. DO NOT INSULATE THE FIREPLACE ITSELF. CAUTION: The unit does not have to be completely enclosed in a chase. The clearance on top of the unit is 0" to the standoffs so combustible building materials can be laid directly on top of the standoffs. You must maintain clearance from the vent to combustible materials for both rigid and flex, see Vent Clearances in the "Clearances" section. P121-10 - See Thru Framing Dimensions P121-10 (See Thru) P131-10 (Pier) A 25"(635mm) minus 2X the finishing material thickness* B 42-1/2"(1080mm) A 25"(635mm) minus 1X the finishing material thickness* B 42-1/2"(1080mm) C 46-3/4"(1187mm) C 45" (1143mm) minus 1X the finishing material thickness* * Finish material thickness includes: drywall, ceramic tile, slate, etc. P131-10 - Pier Note: These units are non-load bearing.

CLEARANCES The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams in the "Locating Your Fireplace" section): Clearance to Combustibles from: Back 0" (0mm) Side 0" (0mm) Floor 0" (0mm) CAUTION REQUIREMENTS: The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoffs may NOT be recessed into combustible construction. Determine the total thickness of the finished floor (eg. tile, carpet, slate) to allow the finished surface to be flush with the base of the unit. Ceiling Height from Floor 72" (1828mm) Mantel Height from Base of Unit: 39" min. (991mm) WARNING: Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Horizontal Vent Clearances: Top 2-1/2" (64mm) Side 1-1/2" (38mm) Bottom 1-1/2" (38mm) Vertical Vent Clearances 1-1/4" (32mm) COMBUSTIBLE MANTELS Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in Diagram to the right. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board. This drawing is to scale at 1:6 (one inch = 6 inches) Mantel can be installed anywhere in shaded area or higher using this scale. Caution: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. * If the 3" (76mm) metal extension trim is removed it must be replaced with a 8" (203mm) non-combustible material. Mantel Clearances

Facing & Finishing Requirements This fireplace is supplied with a 3" metal extension trim above the fireplace. The extension trim may be replaced if the framing is faced with a noncombustible material placed flush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.) UNIT ASSEMBLY PRIOR TO INSTALLATION The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position. Top Standoff Assembly The top standoffs are shipped in a flat position and must be folded into shape and attached. 1) Remove the standoffs from the fireplace top. 2) Take each standoff and bend into the correct shape. Bend up at the bend lines until the screw holes in the standoff and the prepunched screw holes on the fireplace top line up. 3) Attach the standoff securely to the top with 4 screws per standoff (on opposite corners). VENTING INTRODUCTION The P121-10/P131-10 uses the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney. Note: These flue pipes must not be connected to any other appliance. The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited. (See "Rigid Pipe Venting Systems" for more details and exceptions).

Min. 12"* (305mm) Dura-Vent Min. 12"* (305mm) Gas Fireplaces Window Well VENTING ARRANGEMENT - HORIZONTAL TERMINATIONS Regency Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P121-10/P131-10 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent Termination Locations" section. Terminations: For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall Terminations and the Riser Vent are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down. 6-7/8" dia. flexible liner (2 ft. length) 4" dia. flexible liner (2 ft. length) spring spacers (3) thimble (2) AstroCap termination cap (1) screws (12) tube of Mill Pac (1) plated screws (8) screws #8 x 1-1/2" drill point, stainless steel (4) Gravel Riser Vent Termination Regency Direct Vent (Flex) System Termination Kit (Part# 946513) includes all the parts needed to install the P121-10/P131-10 with a maximum run of 2 feet. If installing the P121-10/P131-10 with a continuous vent length of more than 2 ft. (.6m) to a maximum of 10 ft. (3.0m) use Kit # 946-515 (4 ft.) or 946-516 (10 ft.) 1) 2) 3) 4) 5) 6) 7) 8) 9) Adequate drainage Terminations Dura-Vent Dura-Vent Min. 12"* (305mm) Min. 6-1/4"* (159mm) Ade dra Grave Below Grade Installation (Dura-Vent Only) If the Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Termination. Refer to Rigid Pipe Installation instructions for details. Do not attempt to enclose the within the wall, or any other type of enclosure. Riser Vent Termination 23 Min. 6-1/4"* (159mm) Dura-Vent Min. 12"* (305mm) Dura-Vent Min. 12"* (305mm) Window Well Adequate drainage Gravel Notes: 1) Liner sections should be continuous without any joints or seams. Riser Vent Termination 2) Only Flex pipe purchased from Regency may be used for Flex installations. 3) Regency Direct Vent System (Flex) is only approved for horizontal terminations. Min. 6-1/4"*

Rigid Pipe Venting Horizontal or Vertical Terminations Vertical Venting with One (1. 90 Elbow Two 45 elbows = One 90 elbow Option V H Maximum total pipe: length, of all A) 1 Min. 2 Max. sections, must not exceed 37 feet. Total horizontal sections must not B) 2 Min. 4 Max. exceed 8 feet. C) 3 Min. 6 Max. Minimum of 1 foot between 90 elbows is required. D) 4 Min. 8 Max. Venting Arrangements - Vertical Terminations Rigid Pipe System (Propane & Natural Gas) The P121 /131 is approved for a maximum 35 ft. straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas. Vent must be supported at offsets. Horizontal sections must be supported every 3 feet. Firestops are required at each floor level and whenever passing through a wall. Maintain clearances to combustible materials. Minimum of 1 pipe section between elbows. Note: Must use optional flue adapter when using Rigid Pipe (Part # 510-994. IMPORTANT When installing this unit vertically, the 45 elbow when installed in conjunction with the Rigid Pipe Adapter will protrude past the unit 1-½ (38mm) when measured from the rear standoffs. Note: A 1-¼ (32mm) clearance from the elbow must also be maintained. o 45 Elbow Rigid Pipe Adapter Maximum 35'(10. 6 7m) Minimum 6' 6 (2.0m ) 1-1/2 (38mm) 45 Elbow Rigid Pipe Adapter Part # 510-994

Vertical Venting with Two (2) 90 o Elbows A) Option 1' (305mm) Minimum V + V1 4' (1.22m) Maximum H B) 2' (610mm) Minimum 6' (1.86m) Maximum C) 3' (914mm) Minimum 9' (2.7m) Maximum D) 4' (1.22m) Minimum 12' (3.6m) Maximum E) 5' (1.5m) Minimum 15' (4.5m) Maximum F) 6' (1.86m) Minimum 17' (5.1m) Maximum minimum of 6 feet total vertical and maximum 17 feet total horizontal. Vertical Venting with Two (2) 90 o Elbows Option V H + H1 A) 1' (305mm) Minimum 2' (610mm) Maximum B) 2' (610mm) Minimum 4' (1.22m) Maximum C) 3' (914mm) Minimum 6' (1.86m) Maximum D) 4' (1.22m) Minimum 8' (2.4m) Maximum minimum of 4 feet total vertical and maximum 8 feet total horizontal. Diagram 9 Diagram 10 Vertical Venting with Three (3) 90 o Elbows Option V + V1 H H + H1 A) 2' (610mm) Min. 1' (305mm) Max. 2' (610mm) Max. B) 3' (914mm) Min. 4' (1.22m) Max. 5' (1.5m) Max. C) 4' (1.22mm) Min. 6' (1.86m) Max. 8' (2.4m) Max. D) 5' (1.5m) Min. 8' (2.4m) Max. 12' (3.6m) Max. minimum of 5 feet total vertical and maximum 12 feet total horizontal. Diagram 11

Venting Arrangements - Horizontal Terminations This diagram shows allowable venting configurations using one 45. Note: Must use optional flue adapter (Part # 510-994. when using Rigid Pipe. Maintain clearances to combustibles. Horizontal vent must be supported every 3 feet. Firestops are required at each floor level and whenever passing through a wall. Horizontal Venting with One (1. 90 Elbow Two 45 elbows = One 90 elbow Option V H Maximum total pipe: length, of A) 1 Min. 3 Max. all sections, must not exceed 37 feet. B) 2 Min. 6 Max. Total horizontal sections must C) 3 Min. 9 Max. not exceed 17 feet. Minimum of 1 foot between D) 4 Min. 12 Max. 90 elbows is required. E) 5 Min. 15 Max. F) 6 Min. 17 Max. A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. Note: FPI Direct Vent System (Flex) is only approved for horizontal terminations.

Horizontal Venting with Two (2) 90 o Elbows Horizontal Venting with Three (3) 90 o Elbows Option V H + H1 A) 1' (305mm) Minimum 2' (610mm) Maximum B) 2' (610mm) Minimum 5' (1.5m) Maximum C) 3' (914mm) Minimum 8' (2.4m) Maximum D) 4' (1.22m) Minimum 11' (3.35m) Maximum E) 5' (1.5m) Minimum 14' (4.27m) Maximum F) 6' (1.86m) Minimum 15' (4.5m) Maximum minimum of 6 feet total vertical and maximum 15 feet total horizontal. Option V H H + H1 + H2 A) 2' (610mm) Min. 1' (305mm) Max. 3'(914mm) Max. B) 3' (914mm) Min. 3' (914mm) Max. 6' (1.86m) Max. C) 4' (1.22mm) Min. 5' (1.5m) Max. 9' (2.7m) Max. D) 5' (1.5m) Min. 7' (2.13m) Max. 12' (3.6m) Max. minimum of 5 feet total vertical and maximum 12 feet total horizontal. Diagram 5 Diagram 3 Horizontal Venting with Two (2) 90 o Elbows Option V H H + H1 A) 1' (305mm) Min. 1' (305mm) Max. 3'(914mm) Max. B) 2' (610mm) Min. 3' (0.91m) Max. 6' (1.86m) Max. C) 3' (914mm) Min. 5' (1.5m) Max. 9' (2.7m) Max. D) 5' (1.5m) Min. 8' (2.4m) Max. 12' (3.6m) Max. minimum of 5 feet total vertical and maximum 12 feet total horizontal. Horizontal Venting with Three (3) 90 o Elbows Option V + V1 H + H1 A) 2' (610mm) Minimum 3' (914mm) Maximum B) 3' (914mm) Minimum 6' (1.86m) Maximum C) 4' (1.22m) Minimum 9' (2.7m) Maximum D) 5' (1.5m) Minimum 12' (3.6m) Maximum minimum of 5 feet total vertical and maximum 12 feet total horizontal. Diagram 4 Diagram 6