Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

Similar documents
POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Powerflow Unvented water heater

Handyflow Undersink HF05MVC

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Automatic Infrared Tap TAPIFR. Instruction Manual

Zen Boiling Tap Range

Unvented Electric Water Heater 10/15 litre Undersink

ZIP Aquapoint III. Direct unvented water heaters Models: AP3/05, AP3/05/OB, AP3/10, AP3/10/OB, AP3/15, AP3/15/OB.

HS&S Alert No: 103 Date: 9 March 2017

Product Instruction Manual. Jetstream JET1600 (white) & JET1600BSS (brushed stainless steel) 1.6 kw automatic hand dryer V15.

UNVENTED WATER HEATERS. Water Heater Display Stand

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

ZIP VARIPOINT II Direct unvented water heaters.

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

TH01B, TH02B, TH03B, TH04B

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

SC2000Y, SC2000YST, SC2000YM

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

HOTFLO 10 / 15. Fitting Instructions and User Guide

Unvented water heater

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

Installation and User Instructions HS10U, HS15U.

AC500T, AC1000T, AC1500T, AC2000T

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

OWNER S GUIDE. Electric and Gas Storage Water Heaters. Safety Information Owner s Information Warranty. Models

Owner s Manual. Installation Details Owner s Information Warranty. Electric Storage Water Heaters

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

Installation, operating and servicing instructions

Owner s Manual. Installation Details Owner s Information Warranty. 25L and 50L Electric Storage Water Heater

INSTALLATION AND OPERATION MANUAL

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Streamline Undersink. Fitting Instructions and User Guide

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Operation / Installation Manual

TH100 Three in One Instant Hot Water Tap

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Powerstock Storage Tank

DRINKING WATERCOOLER MANUAL. Website:

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

HOTFLO 10 / 15. Fitting Instructions and User Guide

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Installation Instructions / Operating & Maintenance Manual Ablution Plant Model BTHW-1

Unvented water heater

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

OWNER S MANUAL WARRANTY INFORMATION AND INSTALLATION INSTRUCTIONS PROFLO AND MARATHON ELECTRIC STORAGE WATER HEATERS

Installation, Operating and Servicing Instructions

SMART SHOWERS ELITE SP P0985 READ ME THIS IS A HIGH PERFORMANCE HIGH SPECIFICATION PUMP AND HAS PRECISE INSTALLATION REQUIREMENTS

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

ELECTRIC WATER BOILER

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Thermostatic bar mixer valve with adjustable head Installation guide

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

Bar valve with fixed and adjustable shower heads. Installation guide. Midas Plus installation instructions Page 1

Oltis thermostatic bar mixer

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

AQ150:Midas 10/9/15 14:50 Page 1 AQ150. Thermostatic bar mixer valve with adjustable head. Installation guide

Panamatic. Midi & Mini. Installation instructions.

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

e50 Installation guide

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Closomat Lima Vita installation & user guide

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Dove Eco thermostatic bar mixer shower

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Sema thermostatic bar mixer Installation and operating instructions

STEAM WALLPAPER STRIPPER MODEL HTW5

Thermostatic bar mixer shower. Installation and Operating Instructions. Installers please note these instructions are to be left with the user

Installation Instructions Flute Tap Range

Miscellaneous. TMV3 Mixing Valves. TMV3 Thermostatic Mixing Valves. Specifications. Temperature Readout. Features include:

Hotflo. Unvented point of use hot water

Mira Reflex Thermostatic Bar Valve

Electrical Mini Tank Water Heater anual, and Warranty nformation

Alpha CombiMax 350 and 600

Dene Bath Shower Mixer

Bath Shower Mixer

Technical and Installation manual All Models

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions


ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

X62 Tap Range. Please keep these instructions for future reference

TECHNICAL PROPERTIES OF THE APPLIANCE

Transcription:

Speedflow Undersink Unvented Water Heater Models SF05K, SF10K and SF15K Instruction Manual Version 3.0 June 2010

HYCO SPEEDFLOW UNVENTED WATER HEATER MODELS SF05K (5 Litres) SF10K (10 Litres) AND SF15K (15 Litres) 1. INTRODUCTION Thank you for purchasing a Hyco Speedflow unvented water heater. This product operates at mains water pressure and can supply hot water using ordinary taps. CAUTION THE SPEEDFLOW MUST BE INSTALLED AND MAINTAINED BY A COMPETENT PERSON IN ACCORDANCE WITH CURRENT ELECTRICAL AND PLUMBING REGULATIONS. IT IS ESSENTIAL THAT THE ENCLOSED PRESSURE RELIEF VALVE IS FITTED MAKE PLUMBING CONNECTIONS WITH FLEXIBLE STAINLESS STEEL HOSES TO FACILITATE FUTURE MAINTENANCE ALWAYS FIT THE HEATER THE CORRECT WAY UP (PIPES SHOULD BE AT THE TOP) USE LOWEST ACCEPTABLE TEMPERATURE SETTING TO SAVE ENERGY AND REDUCE LIMESCALE DO NOT CONNECT TO POWER UNLESS UNIT IS FULL OF WATER OPEN TAP AND ALLOW WATER TO FLOW FREELY TO CLEAR AIRLOCKS DO NOT SWITCH POWER ON IF WATER IN HEATER OR PIPES COULD BE FROZEN 2. INSTALLATION (WALL MOUNTING) The Speedflow is normally fitted immediately below the outlet to be supplied, but it can be mounted above or to the side of the outlet provided it is vertical with the pipe outlets at the top. The unit can either be placed directly on the floor or fixed to a wall using the mounting bracket supplied. 1 ENSURE THE MOUNTING SURFACE IS STRONG ENOUGH TO SUPPORT THE SPEEDFLOW INCLUDING THE WEIGHT OF THE WATER. The 5 litre model (SF05K) can typically serve 1 sink, the 10 litre model (SF10K) can typically serve 1 or 2 sinks and the 15 litre model (SF15K) can typically serve 2 or 3 depending on simultaneous usage.

3. PLUMBING CONNECTIONS A service valve should be fitted to allow / facilitate future maintenance. THE SUPPLIED 6 BAR PRESSURE RELIEF VALVE MUST ALWAYS BE FITTED. THERE MUST BE NO OBSTRUCTIONS IN THE PIPEWORK BETWEEN THE HEATER AND THE RELIEF VALVE. THE RELIEF VALVE MUST DISCHARGE TO A SAFE AND VISIBLE PLACE. The hot and cold fittings are ½ BSP and are at the top of the unit. These connections are colour coded (blue = cold, red = hot). They are not interchangeable. The final connection of the Speedflow to pipework should be implemented with flexible stainless steel hoses. OPEN HOT WATER TAP AND ALLOW WATER TO RUN THROUGH FOR AT LEAST 5 SECONDS TO CLEAR AIRLOCKS. Depending on the installation circumstances, other accessories may be required. If required, these must be ordered separately and are installed as shown on the diagrams below and on the next page. Water pressure can increase considerably at night when demand is low, so a pressure reducing valve may be required even if there is no obvious problem at installation. DIAGRAM A - Pressure below 4.2 bar 1.4 (5L), 2.8 (10L) or 4.2 (15L) metres is required for expansion in pipework No accessories needed 2

DIAGRAM B - Cold draw off nearby Accessory SF3 needed to prevent expanded warm water entering cold water supply. Kit comprises expansion vessel and check valve. DIAGRAM C - Pressure above 4.2 bar 4. ELECTRICAL INSTALLATION Installation must comply with the latest IEE regulations. Connection should be to a fused switched 13A spur. If the cable length is insufficient, it is recommended that the entire cable is replaced and no joins made to the original. This product must be earthed. Accessory SF4 needed to prevent pressure relief valve discharging constantly Kit comprises pressure reducing valve, expansion vessel and check valve IMPORTANT: DO NOT SWITCH THE HEATER ON UNLESS YOU ARE CERTAIN THAT IT IS COMPLETELY FULL OF WATER. FAILURE TO DO SO WILL VOID THE WARRANTY. 3

5. OPERATION Switch on the mains supply. The external neon lamp indicates when the element is heating. USE THE LOWEST ACCEPTABLE TEMPERATURE SETTING TO SAVE ENERGY. HOT WATER MAY PRESENT A SCALDING HAZARD, ESPECIALLY TO CHILDREN OR THE INFIRM. A THERMOSTATIC BLENDING VALVE IS RECOMMENDED IN HIGH RISK SITUATIONS. 6. THERMAL CUTOUT RESET, ELEMENT REPLACEMENT AND ANODE REPLACEMENT DISCONNECT ELECTRICITY SUPPLY BEFORE MAINTENANCE. A re-settable safety thermal cut-out switches off the element in the event of the unit over-heating. The thermal cut-out may trip occasionally in normal use. If this happens the heater will not heat water and the element light will not come on. The thermal cut-out is located underneath the unit behind the grey access plate. Depending on the mounting position of the unit, you may need to uninstall the unit for ease of access to the cutout. In these cases, disconnect electricity supply and unscrew flexible hose connectors. Drain water from heater and locate grey access plate. Remove the cover retaining screws and gently prise cover off. The thermal cut-out will be visible, as shown below. Thermal cutout - Press to reset. Element flange - remove to access anode. Element securing bolt (x4) Allen key required to remove. 4

6. THERMAL CUTOUT RESET, ELEMENT REPLACEMENT AND ANODE REPLACEMENT (continued) To reset the cutout, depress the button in the centre of the device. If the device has tripped reduce the thermostat setting if possible. If the device trips repeatedly with a low thermostat setting, contact Hyco Technical Department on 01977 517555. To access the element or anode, unscrew the bolts holding the flange in position. The element and anode can then be removed. Reverse to re-fit. 7. MAINTENANCE A grey cylindrical magnesium sacrificial anode is fitted to the element to aid tank corrosion resistance. The anode condition should be inspected annually and replaced if the there are signs of significant corrosion. The pressure relief valve should be checked annually by twisting the cap and verifying water is discharged. 5

8. TROUBLE SHOOTING SYMPTOM POSSIBLE CAUSE SOLUTION Water constantly flows from pressure relief valve Water flows from pressure relief valve during heating cycle only Water is not heated Small volume of hot water Water appears to leak from heater Water pressure is too high (above 4 bar). Heated water cannot expand back up inlet pipe due to obstruction. 1. Thermal cut-out has tripped. If problems persist contact Hyco Technical Dept on 01977 517555. Fit Pressure Reducing Valve Kit (Hyco Kit SF4). Fit Expansion Vessel Kit (Hyco kit SF3). 1. See section 6. Check heater is correct way up (pipes at top). 2. Element has failed. 2. Replace element. See section 6 for access to element. 3. Thermostat has failed. 3. Replace thermostat. 1. Unit upside down. 1. Re-install correct way up. 2. Thermostat set too low. 2. Increase thermostat setting. 3. Thermostat fault. 3. Replace thermostat. 1. Poor connections to pipework. 1. Check plumbing connections, especially those to inlet and outlet. 2. Element gasket leak. 2. Refit gasket, tighten flange bolts evenly. Do not over tighten. See section 6 for access to element. 6

9. SPECIFICATIONS Supply Power Tank Capacity Tank Material Dimensions (h x w x d) Pressure relief valve setting Thermal cutout 230V ~ 50Hz 2kW SF05K 5 Litres SF10K 10 Litres SF15K 15 Litres Vitreous enamel lined steel SF05K 320 x 280 x 245 mm SF10K 410 x 310 x 280 mm SF15K 530 x 310 x 280 mm 6 bar Manual reset 10. GUARANTEE AND SERVICE POLICY This product is guaranteed against fault materials and manufacture for a period of one year from the date of purchase. Hyco will in its sole discretion replace, repair or refund any faulty unit. Incorrect installation and the consequences of limescale deposits are excluded. Consequential costs such as labour charges or damage to fittings are expressly excluded. Hyco Manufacturing Ltd California Drive Whitwood Castleford West Yorkshire WF10 5QH 7 Tel: 01977 517555 Fax: 01977 517666 Web: www.hyco.co.uk E-mail: sales@hyco.co.uk