Mercury RV Water Heaters. Duoetto. HCE-10 Dual Voltage 12VDC/240VAC. P.O. Box 777, Leichhardt, NSW 2040

Similar documents
IMPORTANT SAFETY INSTRUCTIONS

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

WH-TD20B3E5 WH-TD30B3E5

CB-CW-1 Cool/Warm Mattress Owner s Manual. Contents

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6

NEPTUN I Sole cleaning unit Art.-No.:

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

FAN COILS wall mounted

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

User manual Whirlpool

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

Vacuum Pack Machine Instruction Manual Model GF439-A

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

USER S MANUAL HSC-14/18/24/24A

100 Series Maxi Internal Filters

air conditioner/dehumidifier 9000btu/hr

OPERATING INSTRUCTIONS

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Universal Clamp Meter

Ireland. Australia. New Zealand

Window-Type Air Conditioner

Refresh & Clean Carpet Washer

SOLID PLUS HEAT

DOMESTIC STEAM GENERATOR Installation Instructions

Operating and assembly manual: Electric instantaneous flow heater Admiral

Removing shipping locks

AM 213 Installation Introduction

T35 W35. Thermoelectric cooler Instruction Manual. Thermoelektrische Kühlbox. Glacière thermoélectrique. Nevera termoeléctrica

ONE. User Manual. Heating Element and Electric Radiator

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

INSTRUCTION MANUAL HAND HELD STEAM CLEANER JQ688A-1

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Moisture inside the drum is due to final testing.

Table 1. Serie of Digital Room Thermostats.

Technical documentation: S1 S2 S3 S4

Installation Instructions & Operating Manual IMPORTANT

KADO LUX LED EXHAUST FAN 200

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

ELECTRIC WATER HEATER HT382E55

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

USER MANUAL TPS-M5/M55/M555

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

V80-H Multistage Pump Instruction Manual

VADA - Rain2Main Automatic Rainwater Controller

Portable Refrigerator

Dehumidifier. Instruction Manual. Model DH-320/A

GAN Electronic 750W/1000W DE EU

CLASSIC PLUS INFRARED ZONE HEATER

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

V 120 SG - V 160 SG. Instructions for use

Water Boiler. Instruction manual. Model: GL346-A/GL347-A/GL348-A/GL349-A

PC20-AMFII / PC40-AMF USER MANUAL

Instructions for Installation and Use

Owner s Manual. Installation Details Owner s Information Warranty. Electric Storage Water Heaters

Stainless Steel Kettle

12,000 BTU Evaporative Portable Air Conditioner

Instruction Manual. Portable Air Conditioner

Heater-Controller Package manual

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

Dual Tank Deep Fryer. Use and Care Instructions. Double Capacity Twice the Power Easy Cleanup

2400W steam generator with one touch temperature control. Instruction Manual MODEL: SI9020TTN

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

LUCCI AIRFUSION BREEZE WALL FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE

STEAM GENERATOR. Model: G-1030ST. Instruction Manual

ELECTRIC FIREPLACE CONVERTER KIT OWNERS MANUAL Model Number: EF05-23

DC COMPRESSOR FRIDGE-FREEZER Grape Glacier 2.75 INSTRUCTION MANUAL ENGLISH

INFRARED ZONE HEATING SYSTEM

Steam Generator. Item no.: SI9020N /v1.1. Swan Products Limited, PO Box 3117, Stoke on Trent, Staffordshire, ST4 9GD

Portable Air-conditioner Use and Care Manual

ER MANUAL FOR YOUR BAUMATIC

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Technical documentation WATER HEATED AIR CURTAIN MODELS: REVENTON GROUP AERIS 100WN-1P REVENTON GROUP AERIS 150WN-1P REVENTON GROUP AERIS 200WN-1P

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Installation Manual for M-G014 & M-G015

Series: MBC1-TC Mini Benchtop Temperature Controller

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

Notices for installation

INSTRUCTION MANUAL Wall mounted Cooker hood Nebel INOX 90

INSTALLATION GUIDE NZ AU E

Owner s Manual. Installation Details Owner s Information Warranty. 25L and 50L Electric Storage Water Heater

INSTALLATION INSTRUCTIONS

OWNER S GUIDE. Electric and Gas Storage Water Heaters. Safety Information Owner s Information Warranty. Models

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

Technical documentation DTR

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Evap WTW INSTALLATION INSTRUCTIONS D

SHOWER WATER HEATER MODEL X-SLIM 35 EC / X-SLIM 45 EC OPERATION AND INSTALLATION INSTRUCTIONS

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

HEA USER MANUAL. 1 Version: 22. June 2010

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

SCHWAN INSTALLATION GUIDE

MODEL: DC10RCDH / DC12RCDH

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Portable Air Conditioner

INSTALLATION GUIDE NZ AU D

Portable Air-conditioner

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Portable Air Conditioner. Instruction Manual

Transcription:

Mercury RV Water Heaters Duoetto HCE-10 Dual Voltage 12VDC/240VAC www.ausj.com.au sales@ausj.com.au P.O. Box 777, Leichhardt, NSW 2040

Thank you for your purchase of the Duoetto Dual Voltage Water Heater! This device is approved to European Quality Standards, CE, as well as AS/NZS 60335.2.21 : 2002 A1-3. The Duoetto is a simple system with high quality parts designed to meet your needs. Please read the instruction manual for maintenance and correct installation and operation of the Duoetto. Should any fittings be required for your installation, we have a range which can be viewed on our website. A sample elbow fitting has been included with your purchase. 1. Product Features Intelligent The Duoetto has an advanced thermostat. This thermostat allows the water temperature to be set between 30 C and 75 C. It will sustain the set temperature when in operation. Durable and Elegant The exterior shell is made of high quality plastics and is both elegant and durable. The tank inside is made of high-quality 304 food grade stainless steel. Environment Friendly and Efficient High-Density non-fluorine thermal layer provides excellent heat preservation, saving electricity through maintaining the temperature. Multi-Functional Protection Creepage proof, over-temperature proof, dry burning proof and over pressure protection all work in sync to make this a reliable and safe water heating option. MODEL: HCE-10, HCE-5 Electric Storage Water Heater 2. Accessories and Data The following accessories should be included with your unit. No. Item Quantity 1 Duoetto Water Heater 1 2 Self-Tap Screws 4 3 Combined Pressure Relief Valve 1 4 Owner s Manual 1 5 Hose 1 6 DVD 1

3. List of Technical Parameters Feature HCE-10 HCE-5 AC240v DC12v AC240v DC12v Rated Capacity(L) 10L 5L Rated Voltage(V) 220~V 12v-24v 220~V 12v-24v Rated Power(W) 1000W 300W 1000W 180W Rated Current(A) 4.6A 25A 4.6A 25A Rated Tank 0.6Mpa 0.6Mpa Pressure(Mpa) Net Weight(Kg) 5kg 4kg Gross Weight(Kg) 5.5kg 5kg Dimensions(mm) 425x235x235mm 210x220x265mm Mounting Mode Horizontal Horizontal 4. Waterflow Scheme 5. Safety Cautions Electrical safety requires that this unit be earthed according to the working rules of installations of electrical goods. The location this Duoetto water heater is installed in should be able to support the weight of the water system when it is full of water (Approx. 15kg). The Duoetto must be filled with water before given power during the first use. The Duoetto is not allowed to heater without water (run dry). Ensure that the electrical installation has wiring sufficient for the Duoetto unit. The power socket must have reliable earthing.

Don t handle the plug with a wet hand. Do not operate this device if the cord, feed or plug is damaged in any fashion. Don t replace the safety valve with any unauthorized products. The blowdown hose on the outlet of the pressure relief valve should be kept downward and open to the air. Water release from the hose is normal due to pressure within the tank, do not block this hose. 6. Installation Installation is the responsibility of the buyer and the manufacturer does not bear the responsibility for any damages caused by incorrect installation, damage due to poor quality plumbing and parts, non-standard water or not following these instructions. Mounting the Heater - Drill 2 holes on a firm wall. Distance between the two holes is 200mm for the HCE-10 Duoetto and 100mm for the HCE-5 Aqueous. (Shown in Fig 3) - Screw the hooks on until they are tight, keep the hooks upward. (Shown in Fig 4) - Hang the heater on the hooks. (Shown in Fig 5) - Having a strap supporting the heater is also advisable. It is recommended that the Duoetto water heater be as close as possible to the place of use to reduce loss of heat in piping. It is also recommended to fit a strap around the Duoetto to add strength to the mounting. Warning: The wall must be strong enough to support the Duoetto s weight filled with water (Approx. 15kg). Pipe Connection

- Screw the pressure relief safety valve onto the inlet, with the arrow on the valve pointing upward toward the water heater. Do not remove the small screw on the pressure relief valve. - Connect the inlet to the water supply. (Fig 6) During operation you may observe a small leak of water from the drainage hose connected to the pressure relief valve, this is normal due to the expansion of water while heating. Notices: - No responsibility is taken by the manufacturer for damage caused to the unit when not using the supplied pressure relief valve. - If the water pressure exceeds 0.6Mpa a pressure reducing valve must be used. Use of the Duoetto - Open the outlet and inlet pipelines until water flows out normally, demonstrating that the inlet and outlet works normally and the heater is full of water. - Close the outlet valve. - Check all joints to see if there is any leakage. - When first using the water heater, ensure that the Duoetto Water Weater is filled with water and that water flows from the outlet and only then introduce any power to the system. Power Connection Before introducing any power to the Duoetto Water Heater make sure the water heater is filled with water. 240V Installation 1. Power supplies must be on a network with an alternating current of 50 Hz 240V. 2. The water heater is equipped with a regular cord and power plug. 3. The socket should be grounded and protected from moisture.

4. The device must maintain circuit breaker protection. 12V Installation All appliance installations should be only carried out by a qualified individual. 1. Connect the red 5mm large wire directly to house battery or another suitable power source. 2. Connect the black 5mm large ground wire to an earth point or a negative battery terminal. 3. Connect the small black ground wire to an earth point and the small red wire to a switched power source. Important: To avoid draining the engine crank battery, the red small positive wire must be connected to a switch or an ignition source. (Applicable for the HCE-10/12V Type Only). 7. Methods of Usage Heat Up - Plug in the Duoetto after making sure it is filled with water. - Turn the thermostat to the desired temperature and switch the heater on. Indicator lights indicate the heater is functioning. - Water temperature is adjustable from 30 C to 75 C. - The Duoetto Water Heater is auto thermostatic. It automatically cycles on and off when it reaches the set temperature. On/Off Switch: Controls 240VAC heating. When it switches on, the 12V heating will not work. The Duoetto will be heating on 240VAC power. The red light will not turn off even when the heater stops heating. DC LED: A light indicates 12V heating. It will turn off when the heater is being powered by 240VAC. Thermostat: The thermostat controls both 12V and 240V heating, it controls the DC LED but not the AC light. Over Temperature Protection This protects the Duoetto Water Heater from overheating. It disconnects a heating element from the network at temperatures in excess of 85 C. Safety systems cannot automatically reset. Refer to maintenance for resetting. Over Pressure Protection When the internal pressure is higher than the rated tank pressure the safety valve will automatically release pressure. It is normal that water is blown down from the pressure relief outlet. 8. Maintenance Note: Regular maintenance service is not included in the guarantee certificates of the manufacturer or seller.

To clean the shell of the Duoetto Water Heater, do not spray water directly onto it. After the power is disconnected, use a soft wet cloth to clean it, drying with a dry cloth afterward. Keep the water heater shell dry and clean. 9. Troubleshooting Problem Possible Cause Possible Resolution The pressure of the hot water from the Duoetto has decreased. The cold water pressure remains the same however. Contamination of the inlet aperture or the safety valve. Time to heat the water has increased. The over-temperature protector is triggered during operation The heating element may be covered in scum. The electric system may have reduced in quality. The temperature is close to its limit. The tube of the thermostat has become covered with scum. Try removing the valve and washing it out in clean, pure water. Clean the heating element. Service the electrical system. Turn the thermostat to a lower temperature. Clear the tube of scum. Warnings: Water Heaters using 240VAC must use a reliable grounding socket. If you find any earth failure or abnormality, stop using the water heater immediately, unplug the heater and contact your supplier for service. 10. Guarantee Certificates - The guarantee on this water heater is 12 months supply of parts within Australia (from the date of sale). - Supply of spare parts is carried out free of charge within the warranty period. Note: Infringement of the instruction manual procedures cancels the warranty period and any complaints will not be accepted. 11. CIRCUIT DIAGRAM Only install your appliance in accordance with any state or territory regulations with a qualified installer.

12. 12V Cable Length and Current Capacity Guide Current, Length (Twin) to area (sq mm) 12.6VDC, current carrying capacity(ccc)(top) then follows 5% volt drop to 70 sq mm.

Please fill in all details correctly. Retain this card with original purchase invoice for any future warranty claim. Please note in the event of this document and the original purchase invoice not being provided, warranty will commence from the date of manufacture. Owner s Details: Surname.. Initial Address.. Date of Purchase. Purchased from... Model.. Serial Number.. Installer s Details Date of Installation.. Installer s Name. Address.. Installer s Signature...