GETTING STARTED GUIDE. NI 9212 and TB TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block

Similar documents
GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate

ni.com/manuals For specifications, refer to the NI USB-TC01 Device Specifications document available at ni.com/manuals.

GETTING STARTED GUIDE NI NI-XNET Hardware Selectable Interface. Français Deutsch 日本語한국어简体中文. ni.com/manuals

Certificate of Compliance

INSTRUCTION & SERVICE MANUAL

Certificate of Compliance

Quick Start Guide For the

Fisher LCP100 Local Control Panel

Isolated Thermocouple Module

Gas cylinder scale Model GCS-1

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Vanguard. Toxic & combustible gas detector

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Operation and Maintenance Manual

SEL-3422 Motor Relay HMI Quick-Start Guide

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Snifter ATEX22 VERSION. User Manual. Distributor

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

KM300 Carbon Monoxide Detection System Installation Manual

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Earth-Rite II PLUS Static Earthing System

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

WSD-E WHEEL DETECTOR QUICK REFERENCE GUIDE JUNE 2016 DOCUMENT NO. SIG-QG VERSION A

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

Safe Operation Manual. Honeywell IQ Force Gas Detector

Environmental Monitoring SmartSlot Card

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Annubar Flowmeter Series

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Dry Bath Heating Systems

Proliphix Thermostat Installation Guide. Release 2.0

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Reacti-Therm I and III Heating Modules

EtherCAT Box Modules (EPxxxx-xxxx)

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Operating Instructions Edition 02/2007

MODELS 304GC, 304GCX, 314GC, and 314GCX

Operating Instructions

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Room Sensor for BACnet VAV Actuator

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

safety & regulatory information

Square D Clipsal Outdoor Light-Level Sensor

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Rosemount 4500 Hygienic Pressure Transmitter. Start

Refrigerated Incubator Model and Operating Instructions

Certificate of Compliance

LC1350 Level Controller

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Operating Instructions

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

MD-MINI Dry Bath. Instruction Manual

Module Features are-configurable, no module jumpers to set

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

180 Degree Ceiling Mounted Occupancy Sensors

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

3M Benchtop Air Ionizer 963E. User s Guide

SINAMICS G130. Cabinet design and EMC. Operating Instructions 05/2010 SINAMICS

Hazardous Area Zirconia Oxygen Systems

LC2200 Level Controller Installation and Maintenance Instructions

standards: standards:

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

Supplement. Title: 365 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date:

Agilent N4011A MIMO/Multi-port Adapter

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

LC3000 Level Controller Installation and Maintenance Instructions

SEC Signature Process Gas Analyzer

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Max HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Installation and Maintenance Manual IM 1038

Certification Supplement Manual

AUGUST 2016 CONTENTS:

CONTROL BE MADE CHANGES MAY NOT. Page 1

UL HAZARDOUS LOCATIONS SERVICES

Certification Supplement Manual

Installation Instructions

Manual Power relay SR853

Inline Heater for Solvent or Gas. Installation and Operation Manual

SINAMICS G130. Cabinet design and EMC. Operating instructions 03/2011 SINAMICS

Series: MBC1-TC Mini Benchtop Temperature Controller

Transcription:

GETTING STARTED GUIDE NI 9212 and TB-9212 8 TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block

This document explains how to connect to the NI 9212 using the TB-9212. In this document, TB-9212 with screw terminal and TB-9212 with mini TC are inclusively referred to as TB-9212. Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. Note The guidelines in this document are specific to the NI 9212. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system. Safety Guidelines Operate the NI 9212 only as described in this document. Caution Do not operate the NI 9212 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any 2 ni.com NI 9212 Getting Started Guide

way. If the product is damaged, return it to NI for repair. Hazardous Voltage This icon denotes a warning advising you to take precautions to avoid electrical shock. Safety Guidelines for Hazardous Voltages If hazardous voltages are connected to the device, take the following precautions. A hazardous voltage is a voltage greater than 42.4 Vpk voltage or 60 VDC to earth ground. Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards. Caution Do not mix hazardous voltage circuits and human-accessible circuits on the same module. Caution Ensure that devices and circuits connected to the module are properly insulated from human contact. Caution When module terminals are hazardous voltage LIVE (>42.4 Vpk/60 VDC), you must ensure that devices and circuits connected to the module are NI 9212 Getting Started Guide National Instruments 3

properly insulated from human contact. You must use the TB-9212 included with the NI 9212 to ensure that the terminals are not accessible. Note The TB-9212 with screw terminal contains a plastic insert to prevent accidental wire contact with the metal enclosure. Isolation Voltages NI 9212 and TB-9212 with Screw Terminal Isolation Voltages Connect only voltages that are within the following limits: Channel-to-channel isolation Up to 2,000 m altitude Continuous Withstand 250 Vrms, Measurement Category II 1,500 Vrms, verified by a 5 s dielectric test 4 ni.com NI 9212 Getting Started Guide

Up to 5,000 m altitude Continuous Withstand Channel-to-earth ground isolation Up to 2,000 m altitude Continuous Withstand Up to 5,000 m altitude Continuous Withstand 60 VDC, Measurement Category I 1,000 Vrms, verified by a 5 s dielectric test 250 Vrms, Measurement Category II 3,000 Vrms, verified by a 5 s dielectric test 60 VDC, Measurement Category I 1,000 Vrms, verified by a 5 s dielectric test Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live NI 9212 Getting Started Guide National Instruments 5

electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. Caution If using in Division 2 or Zone 2 hazardous locations applications, do not connect the NI 9212 and TB-9212 with screw terminal to signals or use for measurements within Measurement Categories II, III, or IV. Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe. 6 ni.com NI 9212 Getting Started Guide

Caution Do not connect the NI 9212 and TB-9212 with screw terminal to signals or use for measurements within Measurement Categories III or IV. NI 9212 and TB-9212 with Mini TC Isolation Voltages Connect only voltages that are within the following limits: Channel-to-channel isolation, Up to 5,000 m altitude Continuous Withstand 60 VDC, Measurement Category I 1,000 Vrms Channel-to-earth ground isolation, Up to 5,000 m altitude Continuous Withstand 60 VDC, Measurement Category I 1,000 Vrms Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special NI 9212 Getting Started Guide National Instruments 7

equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. Caution If using in Division 2 or Zone 2 hazardous locations applications, do not connect the NI 9212 and TB-9212 with mini TC to signals or use for measurements within Measurement Categories II, III, or IV. Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. Safety Guidelines for Hazardous Locations The NI 9212 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx na IIC T4 and Ex na IIC T4 hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI 9212 in a potentially explosive environment. Not following these guidelines may result in serious injury or death. 8 ni.com NI 9212 Getting Started Guide

Capacitance Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous. Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous. Caution Substitution of components may impair suitability for Class I, Division 2. Caution For Division 2 and Zone 2 applications, install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15. Caution For Division 2 and Zone 2 applications, connected signals must be within the following limits. 0.2 µf maximum Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9212 has been evaluated as Ex na IIC T4 Gc equipment under DEMKO 12 ATEX 1202658X and is IECEx UL 14.0089X NI 9212 Getting Started Guide National Instruments 9

certified. Each NI 9212 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 C Ta 70 C. If you are using the NI 9212 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nc IIC T4, Ex IIC T4, Ex na IIC T4, or Ex nl IIC T4 equipment. Caution You must make sure that transient disturbances do not exceed 140% of the rated voltage. Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC/EN 60664-1. Caution The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15. Caution The enclosure must have a door or cover accessible only by the use of a tool. 10 ni.com NI 9212 Getting Started Guide

Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. NI 9212 Getting Started Guide National Instruments 11

Caution To ensure the specified EMC performance, operate this product only with shielded cables from the product to the thermocouple measurement location. Caution To ensure the specified EMC performance of the TB-9212 with mini TC, you must install a clamp-on ferrite bead (part number 781233-01) on the shield ground wire between the cable and the ground lug. You can use one ferrite bead per device for all cables. Special Conditions for Marine Applications Some products are Lloyd s Register (LR) Type Approved for marine (shipboard) applications. To verify Lloyd s Register certification for a product, visit ni.com/certification and search for the LR certificate, or look for the Lloyd s Register mark on the product. Caution In order to meet the EMC requirements for marine applications, install the product in a shielded enclosure with shielded and/or filtered power and input/output ports. In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. 12 ni.com NI 9212 Getting Started Guide

Preparing the Environment Ensure that the environment in which you are using the NI 9212 meets the following specifications. Operating temperature -40 C to 70 C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity (IEC 60068-2-78) Pollution Degree 2 Maximum altitude Indoor use only. 10% RH to 90% RH, noncondensing 5,000 m Note Refer to the device datasheet on ni.com/manuals for complete specifications. NI 9212 Getting Started Guide National Instruments 13

TB-9212 Pinout TC4+ TC4- TC5+ TC5- TC6+ TC6- TC7+ TC7- TC0+ TC0- TC1+ TC1- TC2+ TC2- TC3+ TC3- TC0 TC1 TC2 TC3 TC4 TC5 TC6 TC7 14 ni.com NI 9212 Getting Started Guide

Table 1. Signal Descriptions Signal TC TC+ TC- Description Thermocouple connection Positive thermocouple connection Negative thermocouple connection NI 9212 Connection Guidelines Make sure that devices you connect to the NI 9212 are compatible with the module specifications. The shield grounding methodology can vary depending on the application. Refer to your thermocouple documentation or the thermocouple wire spool to determine which wire is the positive lead and which wire is the negative lead. Minimizing Thermal Gradients Changes in the ambient air temperature near the front connector or a thermocouple wire conducting heat directly to terminal NI 9212 Getting Started Guide National Instruments 15

junctions can cause thermal gradients. Observe the following guidelines to minimize thermal gradients and improve the system accuracy. Use small-gauge thermocouple wire. Smaller wire transfers less heat to or from the terminal junction. Run thermocouple wiring together near the TB-9212 to keep the wires at the same temperature. Avoid running thermocouple wires near hot or cold objects. Minimize adjacent heat sources and air flow across the terminals. Keep the ambient temperature as stable as possible. Make sure the NI 9212 terminals are facing forward or upward. Keep the NI 9212 in a stable and consistent orientation. Allow the thermal gradients to settle after a change in system power or in ambient temperature. A change in system power can happen when the system powers on, the system comes out of sleep mode, or you insert/remove modules. If possible, use the foam pad in the TB-9212 with screw terminal opening to restrict airflow around the terminals. 16 ni.com NI 9212 Getting Started Guide

NI 9212 and TB-9212 with Screw Terminal Thermocouple Connection Thermocouple Shield TC+ TC- Ground Lug TB-9212 NI 9212 NI 9212 Getting Started Guide National Instruments 17

NI 9212 and TB-9212 with Mini TC Thermocouple Connection Thermocouple Shield TC+ TC- Ground Lug Ferrite TB-9212 NI 9212 Caution Electrostatic Discharge (ESD) can damage the TB-9212 with mini TC. To prevent damage, use industry-standard ESD prevention measures during installation, maintenance, and operation. 18 ni.com NI 9212 Getting Started Guide

Installing the TB-9212 with Screw Terminal What to Use NI 9212 TB-9212 with screw terminal Screwdriver What to Do 1. Connect the TB-9212 with screw terminal to the NI 9212 front connector. NI 9212 Getting Started Guide National Instruments 19

2. Tighten the jackscrews to a maximum torque of 0.4 N m (3.6 lb in.). Do not overtighten the jackscrews. Wiring the TB-9212 with screw terminal What to Use TB-9212 with screw terminal 0.05 mm 2 to 0.5 mm 2 (30 AWG to 20 AWG) wire with 5.1 mm (0.2 in.) of the inner insulation stripped and 51 mm (2.0 in.) of the outer insulation stripped Zip tie Screwdriver 20 ni.com NI 9212 Getting Started Guide

What to Do 1 2 3 4 NI 9212 Getting Started Guide National Instruments 21

1. Loosen the captive screws on the TB-9212 with screw terminal and remove the top cover and foam pad. 2. Insert the stripped end of the wire fully into the appropriate terminal and tighten the screw for the terminal. Make sure no exposed wire extends past the screw terminal. 3. Route the wire through the TB-9212 with screw terminal opening, remove slack from the wiring, and secure the wires using a zip tie. 4. Replace the foam pad in the TB-9212 with screw terminal opening, reinstall the top cover, and tighten the captive screws. Installing the TB-9212 with Mini TC What to Use NI 9212 TB-9212 with mini TC Screwdriver 22 ni.com NI 9212 Getting Started Guide

What to Do 1. Connect the TB-9212 with mini TC to the NI 9212 front connector. 2. Tighten the jackscrews to a maximum torque of 0.4 N m (3.6 lb in.). Do not overtighten the jackscrews. NI 9212 Getting Started Guide National Instruments 23

Connecting the TB-9212 with mini TC What to Use TB-9212 with mini TC Shielded thermocouple Clamp-on ferrite bead (part number 781233-01) What to Do TB-9212 with Mini TC TC0 0 TC1 TC2 TC3 TC4 TC5 TC6 TC7 7 6 5 4 3 2 1 24 ni.com NI 9212 Getting Started Guide

1. Plug the thermocouple into the thermocouple input on the TB-9212 with mini TC. 2. Install a clamp-on ferrite bead on the shield ground wire between the cable and the ground lug. You can use one ferrite bead per device for all cables. NI 9212 Getting Started Guide National Instruments 25

Where to Go Next CompactRIO CompactDAQ NI 9212 Datasheet NI-RIO Help LabVIEW FPGA Help NI 9212 Datasheet NI-DAQmx Help LabVIEW Help RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Located at ni.com/manuals 26 ni.com NI 9212 Getting Started Guide Installs with the software

Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI 9212 Getting Started Guide National Instruments 27

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/ export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2015 2016 National Instruments. All rights reserved. 374358C-01 Dec16