IECEx Certificate. of Conformity

Similar documents
srra, of Conformity IECEx Gert f cate ?-ot,b

slra IEC of Gonformity IECEx Cert f cate ü* t4

IECEx Certificate of Conformity

IECEx Certificate of Conformity

S5000 Gas Monitor. GMS5000.com

Certificate of Compliance

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Dräger Polytron 5700 IR Detection of flammable gases and vapours

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

IECEx Certificate of Conform ity

IECEx Certificate of Conformity

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

IECEx Certificate of Conformity

Dräger Polytron 8310 IR Detection of flammable gases and vapour

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

ULTIMA X5000. MSAX5000.com

MICROpeL 75 Combustible Gas Sensor Part Number: PM

UL HAZARDOUS LOCATIONS SERVICES

IECEx Certificate of Conformity

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

IECEx Certificate of Conformity

Certificate of Compliance

IECEx Certificate of Conformity

Dräger Polytron 8700 IR Detection of flammable gases and vapors

srra IECEx Certificate of Conformity 2-otI - 03 *07 csa Broup certif CÅr 0f'l TopWox lnc. Gunent 2019{,3-07

Fixed Gas Detection System/Meridian CERTIFICATION

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

INSTRUCTION MANUAL (ATEX / IECEx)

Guide for hazardous areas

IECEx Certificate of Conformity

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS


IECEx Certificate of Conformity

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

IRceL CH4 Methane (CH 4

VQ500 Series Combustible Gas Detector Elements

Overview of Hazardous Locations as They Relate to Solenoid Valves

Annubar Flowmeter Series

IECEx Certificate of Conformity

OLC(T) 100 FIXED GAS DETECTOR

ALTAIR 5X Multigas Detector Product Specification

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION & SERVICE MANUAL

3M Oldham OLCT 100. Description. Fixed Gas Detector

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

IECEx Certificate of Conformity

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Certification Supplement Manual

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

THE BELGIAN PIONEER IN GAS DETECTION

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

INSTRUCTION MANUAL (ATEX / IECEx)

Dräger Polytron 8720 IR Detection of carbon dioxide

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

ESD3000 ESD200 Combustible / Toxic Gas Detector

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Dräger Polytron 5100 EC Detection of toxic gases and vapors

IECEx Certificate of Conformity

Dräger Polytron 5720 IR Detection of carbon dioxide

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

ESD500. ESD500 Combustible / Toxic Gas Detector

Operating Instructions

IECEx Certificate of Conformity

THE BELGIAN PIONEER IN GAS DETECTION

User s Manual YTA610 and YTA710 NEPSI Certification

Certification Supplement Manual

Dräger Polytron 8200 Stationary gas detector (CatEx)

GasAlertMicroClip X3 Specifications

Model D12-IR. Digital Gas Transmitter...

OPTIBAR DP 7060 Supplementary Instructions

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Electrical Installations Design, Selection, Erection and Inspection

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Transcription:

IEC -a @ IM IECEx Certificate of Conformity I NTERNATIONAL ELECTROTECH NICAL COMMISSION IEC Gertification Scheme for Elçlosive Atnospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEX SIR 17.0016X Curent lssue No: 0 Certifìcate history: lssue No. 0 (20r 8-01-08) Date of lssue: 201841{8 Page'l of 3 General Monitors lnc 26776 S mpatica Circle Lake Forest, CA 92630 United States of Amedca Equipment: Optional accessory: S5000 Gas Monitor ñred gas detedion system (f ansmitþr and Jundion Box) and Dlgltal Type of Protection: Flameproof, Dust Prctecüon by Endosurc and Ex n. Marking: SS0O0TEmmlttæ: Cemênted Jo nt version: Ex db llc T5 Gb Ex tb lllc T85'C Db Ex na nc llc T4 Gc -55'C<Ta<+75'C lec 60079-29-1 ElelcaC.þidl elþ @ Ex db llb+h2 TS Gb Ex tb lllc T85'C Db Ex na nc llc f4 Gc -55'C<Ta<+75"C tec 60079-29-'1 Àlclesleslerdstd.lEçif o?g:2s.1; 55000 Junc{m Box Cêmênted Joint veßions: Ex db llc T6 Gb Ex lb lllc T85'C Db Ex na llc T6 Gc -55'C<Ta<+75'C Ele!9ed.þi! JsEie!s; Ex db llb+h2 T6 Gb Ex tb lllc T85'C Db Ex na llc T6 Gc -55'C<Tas+75'C DlgllelSss Ex db llc T5 Gb Ex tb lllc T85"c Db -55"C<Ta< +60'C 1. Applies only to the S5000 Gas Monitorfxed Combust ble Gas Detection System. 2. IEC 60079-31 compl ance dæs not imply that the equ pment will detect gas during and afrer exposure to dust and f bers in suspension in a r conditions. Approved for Ìssue on behalf of lhe IECEx Ceriification Body: Position: // N Jones R,A +tc Signature: (for printed version) Date: 20t 8 ^or-ag 1. Th s cert f cate and schedule may only be reproduced in full. 2. This certificate s not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certif cate may be verified by visiting the Official IECEx Website. Certificate issued by: SIRA Certification SeMce CSAGoup Unit 6, Hawaden lndusûial Park Hamrden, D êskle, CH5 3US United lfigdom slra 0mup CERTIFICAT}OH

IEC -a Certificate No: @ TM IECEx Gertificate of Conformity IECEx SIR 17.0016X lssue No: 0 Date of lssue: lvlanufacturer: 20r&01{8 General Monltos 26776 Simpatica Circle Lake Forest, CA 92630 United States of Arnerica Page2ol 3 Additional Manufacturing location(s): This certif cate is issued as verification that a sample(s), representat ve of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacture/s quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certifìcate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specifìed in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079{ :2011 Edition:6.0 IEC 60079-1 :201446 Edition:7.0 IEC 60079-15 :2010 Ed tion:4 IEC 60079-2$1 :2007 Edition:1 EC60079-31 :2013 Edition:2 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 1: Equipment protect on by flameproof enclosures "d" Explosive atmospheres - Part 15: Equipment protection by type of protection "n" Explosive Atmospheres - Part 29-1: Gas Detectors - Performance requirements of detectors for flammable gases Explosive atmospheres - Part 31: Equipment dust gnition protection by enclosure "t" This Cetiificate dog's not indicate compliance with electrical safety and performance requirements othet than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examinat on and lest requirements as recorded in Test Report: GB/SI R/ExTR'1 7 02041 00 GB/Sl R/ExTR.l 7.02521OO Quality Assessment Report: us/ul/q4r10.0004/05

IEC -a CertilÌcate No: IM IECEx SIR 17.0016X IECEx Gertificate of Conformity lssue No: 0 Date of lssue: 201&01-08 Page 3 of 3 Scñedule EQUIPMENT: Equipment and sysferns covered by this certificate are as follows: The 55000 Gas Monitor f xed gas detection system is designed to measure specified percentage volumes of methane and propane gases or a variety of toxic gases or oxygen. The system comprises an 55000 transmitter base unit and an optional 55000 Junction Box f tted with an arrangement of up to a pair of two factory-configured combustible, toxic or oxygen gas sensors. The transmitter enclosure is fitted with associated circuitry, connection facilities and an LED display visible through the viewing window of the enclosure. Refer to the Annexe for additional information. SPECIFIC CONDITIONS OF USE: YES as shown belorr Refer to the Annexe Annex: IECEx SIR 17.0016X issue 0 Annexe.pdf

IEC Ex SIR 17.0016X Issue O srra I CSA Equipment: The is designed to measure specified percentage volumes of methane and propane gases or a variety of toxic gases or oxygen. The system comprises an 55000 transmitter base unit and an optional 55000 Junction Box fitted with an arrangement of up to a pair of two factory-configured combustible, toxic or oxygen gas sensors. The transmitter enclosure is fitted with associated circuitry, connection facilities and an LED display visible through the viewing window of the enclosure. The 55000 Transmitter is the control unit of the and the enclosure of the transmitter is designed for Flameproof (Ex db) and Dust protection by enclosure (Ex tb) with Non-Sparking/ Protected Sparking (Ex na nc) protection. The enclosure is provided with 3/ " NPT or M25 threaded entries which can be fìtted with the sensors described below or suitably certified cable entry devices or blanking plugs. The 55000 Junction Box is the remote mounting unit of and the enclosure of the Junction Box is designed for Flameproof (Ex db) and Dust protection by enclosure (Ex tb) with Non-Sparking (Ex na) protection. The enclosure is provided with 3/q" NPT or M25 threaded entries which can be fitted with the sensors described below or suitably certified cable entry devices or blanking plugs. The Digital Sensor is a catalytic sensing element construction type for the 55000 Gas Monitor fixed combustible gas detection configurations. For toxic and oxygen sensing, the Digital Sensor uses different sensing element types of construction. The enclosure of the sensor is designed for Flameproof (Ex db) and Dust protection by enclosure (Ex tb). See repoft R701419528, IEC ExTR number GB/SIR/ExTRL7.0204100 for complete descriptive details. The 55000 system makes use of three sensor types including a Digital Sensor for combustible, toxic or oxygen gas detection, Universal Gas (passive sintered) Sensors for combustible or toxic gas detection and an IR (infrared) sensor for combustible gas detection, all mounted via conduit entries. The permitted sensor configurations follow:. Two -Digital Sensors (combustible, toxic or oxygen) installed either integral to the 55000 transmitter, one integral and one remote via a 55000 Junction Box or two remote via two separate 55000 Junction Boxes.. One IR400 sensor (combustible) and one Digital Sensor (combustible, toxic or oxygen) installed either integral to the 55000 transmitter or remotely via the 55000 Junction Box. One Universal Gas (passive sintered) Sensor (combustible or toxic) installed either integral to the 55000 transmitter or one remote via the 55000 Junction Box The product model code options of the 55000 gas detection systems (Combustible, toxic or oxygen) featuring the 55000 transmitter, 55000 Junction Box, IR400 sensor, Universal Gas (passive sintered) sensors and the Digital Sensors component are shown in the Model Code Options section below. The applicable configuration limitations resulting from the hazardous area classifications can be derived in the model codes. Date: 08 January 2018 Form 9530 Issue 1 Page 1 of I Sira Gertification Service Tel: +44 (0) 1244670900 Fax: +44 (0) 1244681330 Email: ukinfo@csagroup.org Web: www.csagroupuk.org

srra IEC Ex SIR 17.0016X Issue O Specific Conditions of Use: 550OO transmitter: 1, Under certain extreme circumstances, the non-metallic parts incorporated in the enclosure of this equipment may generate an ignition-capable level of electrostatic charge. Therefore, the equipment shall only be cleaned with a damp cloth. 2. This fixed equipment apparatus is exclusively designed for field mounting in the vertical orientation with restrictions placed around the conduit entry locations permitted for connection of the both the Digital Sensor and IR400 infrared (IR) sensors and Universal Gas Sensors. The equipment is subject to the installation and orientation requirements defined in the product manual. 3. The flameproof joints shall not be repaired. 55000 Junction Box: 1, Under certain extreme circumstances, the non-metallic parts incorporated in the enclosure of this equipment may generate an ignition-capable level of electrostatic charge. Therefore, the equipment shall only be cleaned with a damp cloth. 2. The flameproof joints shall not be repaired, Dioital Sensor: 1. Under certain extreme circumstances, the non-metallic parts incorporated in the enclosure of this equipment may generate an ignition-capable level of electrostatic charge. Therefore, the equipment shall only be cleaned with a damp cloth. 2. The flameproof joints shall not be repaired. 3. If the sensor is uninstalled, the equipment manufacturer shall be contacted prior to reinstalling. 4. The Digital Sensor is provided with a 3/ " NPT thread and shall only be connected to a suitably certified enclosure. The installation to the certified enclosure shall be with five fully engaged threads, tightened wrench-tight. 5. The Digital Sensor shall only be fitted to enclosures having a maximum reference pressure of 7.7 bars. 6. The Digital Sensor shall be connected directly to a suitably certified junction box or instrument for the hazardous area of installation and thereby provide Ex protection for the flying lead connections. 7. For combustible gas detection performance applications, the appropriate Digital Sensor model number shall only be used to construct the ; mounted onto either the 55000 transmitter or 55000 Junction Box enclosures and receive power and control from the transmitter. Date: 08January 2018 Form 953O Issue 1 Page 2 of 8 Tel: +44 (0) 1244670900 Fax: +44 (O) 1244681330 Email: ukinfo(ðcsagroup.org Web: www.csagroupuk.org

SIÍA IEC Ex SIR 17.0016X Issue 0 Conditions of Manufacture: S5OOO transmitter, S5O0O Junction Box and Dioital Sensor: 1. The manufacturer is responsible for and shall include in the instruction manual the minimum pafticulars of all applicable instructional information required for the equipment by clause 30 of EN/ IEC 60079-0 i.., the certificates. - 55OOO transmitter: 1. Dielectric Voltage Withstand Test (per IEC 60079-15, clause 23.2.L) At the end of manufacture, each 55000 transmitter shall be subjected to an electric strength test using a test voltage of 1500 Vac or 2100 Vdc applied between the following test locations for a minimum of 60 seconds. Alternatively, a voltage of 1800 Vac or 2520Vdc may be applied for 0.1 second. There shall be no evidence of breakdown. a. Between the input terminals and the relay terminals. b. Between the metallic enclosure and the relay terminals. 1, Before assembling the Digital Sensor onto the 55000 enclosure creating a combined assembly, the manufacturer is required to conduct batch hydrostatic pressure testing which shall be performed on the Digital Sensor per the requirements of IEC/EN 60079-1 Clause 16.6 on the wire feedthrough from the conduit side with no leakage for the duration of 10 seconds when 15 bars (10 bars times 1.5 factor; 218 psi or 15 bars) of pressure is applied. Example of batch testing: For a production batch of up to 100 units, a sampling of 8 needs to be tested with no failures.. For a production batch from 101 to 1000 units, a sampling of 32 needs to be tested with no failure,. For a production batch from 1001 up to 10000 units, a sampling of 80 needs to be tested with no failures. For any noncompliant test results, t00o/o of all remaining samples in the batch shall be tested, Future batches should be routine tested (100o/o) until confidence is established to reconsider batch testing. Date: 08 January 2018 Form 953O Issue 1 Page 3 of 8 Hawarden, CH5 3US, United Kingdom Tel: +44 (0) 1244 670900 Fax: +44 (0) 1244681330 Email: ukinfo@csagroup.org Web: vr ww.csagrououk.org

srra IEC Ex SIR 17.0016X Issue 0 Model Code Options: The ULTIMA@ X5000 Gas Monitor fixed gas detection system: The S5000 Transmitter; Model on the transmitter enclosure a Model reference Date: OB January 2018 Form 9530 Issue 1 nsm tter control unit of the Fixed Gas Detection System for use gas atmospheres: up to two sensor may be connected either coupled to the or one coupled to the transmitter and the other coupled to Box enclosure - only one senor per lunction Box permitted; ig tal Sensors orl one IR400 sensor and one Digital Sensor or/ one H2S sensor fl-oxic - Passive Sintered) orl one Universal Gas HC ustible - Passive Sintered) - a is for Enclosure Material: 0 = Aluminum - IIB+H2 (flanged/non-cemented) 1 = Aluminum - IIC (cemented) 2 = Stainless Steel - IIB+H2 (flanged/non-cemented) 3 = Stainless Steel - IIC (cemented) ô is for Output Communications 0 = Bluetooth/ Modbus/ HART 1.25 ma 1 = Bluetooth/ Modbus/ HART 3.5 ma 2 = Bluetooth/ Modbus/ HART 1.25 mai RELAYS 3 = Bluetooth/ Modbus/ HART 3.5 ma/ RELAYS 4 = No Bluetooth/ Modbus/ HART 1.25 ma 5 = No Bluetooth/ Modbus/ HART 3.5 ma 6 = No Bluetooth/ Modbusi HART 1.25 ma/ RELAYS 7 = No Bluetooth/ Modbus/ HART 3.5 ma/ RELAYS c is for Relay State: 0 = No Relays 1 = Latch Alarm / Non-Latch Warn De-Energized 2 = Latch Alarm / Non-Latch Warn Energized 3 = Latch Alarm / Latch Warn De-Energized 4 = Latch Alarm / Latch Warn Energized 5 = Non-Latch Alarm / Non-Latch Warn De-Energized 6 = Non-Latch Alarm / Non-Latch Warn Energized 7 = Non-Latch Alarm / Latch Warn De-Energized 8 = Non-Latch Alarm / Latch Warn Energized d is 1 for ATEX/IECEx ee is for an Additional Feature selection: 00 = None (standard) 01= Stainless Steel Tag fff isfor Sensor 1 selection: gggisfor Sensor 2 selection: Sensors: for Sensor Selection fff or gggt (Independently ceftified Ex Equipment Sensors or Ex Component Sensors forming the Combustible Gas Detection System, per 60079-29-1, are denoted by [^] ) - Digital Sensor selections include, D00 = No Sensor or Sensor Body (transmitter only) D01 = No Sensor (sensor body w/blank element) D10 = Carbon Monoxide, 0-100 ppm Dl1 = Carbon Monoxide,0-500 ppm D12 = Carbon Monoxide, 0-1000 ppm 014 = Carbon Monoxide, Hydrogen Resistant 0-100 ppm D16 -- O-25o/o Page 4 of 8 only, cemented joint Limitati db IIC T5 Gb tb IIIC T85'C Db na nc IIC T4 Gc b: -55oC <fa < +7 flanged joint wi ssembly tb IIIC T850C Db na nc IIC T4 Gc -55oC<Ta<+7 Detection System: + two (one sensor to one cemented) db IIC T5 Gb tb IIIC T85"C Db mb: -55oC < Ta < nged) tb IIIC T85'C Db mb: -55oC < Ta < Detection System: + one 1R400 DigÌtal Sensor maybe connected Jundion Box) cemented and flanged) tb IIIC 100.C Db b: -55oC <-fa < +7 Tel: +44 (O\ 1244 670900 Fax: +44 (O\ 1244 681330 Email: ukinfo(ðcsagroup.org Web: www.csagroupuk.org

IEC Ex SIR 17.0016X Issue O slra I Model reference 55000 transmitter (eouioment) Description D20 = Hydrogen Sulfide, 0-10 ppm D21 = Hydrogen Sulfide,0-50 ppm D22 = Hydrogen Sulflde, 0-100 ppm D65 = Combustible, 0-100o/o LEL - Methane [^] D66 = Combustible, 0-100o/o LEL - Propane [^] -IR400 gas detector/ sensor selections include, R00 = No Sensor R13 = Methane, AL [^] R14 = Propane, AL [^] R43 = Methane, SS [^] R44 = Propane, SS [^] R16 = Pentane, AL R17 = Butane, AL R20 = Ethylene, AL R47 = Butane, SS R48=Ethane,SS R50 = Ethylene, SS -Universal Gas HC head sensor selections include, C00 = No Sensor C07 = 11159-11, Stainless Steel [^] C08 = 11159-21, Stainless Steel, High temp. [^] C11 = 11159-1, Stainless Steel [^] CL2 = ILI59-2, Stainless Steel, High Temp. [^] C09 = 11159-81, Stainless Steel C10 = 11159-8, Stainless Steel -Universal Gas H2S head sensor selections include, M00 = No Sensor M11 = 51457-11, Stainless Steel, 0-100 ppm MI2 = 51457-51, Stainless Steel, 0-50 ppm M13 = 51457-91, Stainless Steel, 0-20 ppm M74 = 5I457-t, Stainless Steel, 0-100 ppm M15 = 51457-5, Stainless Steel, 0-50 ppm M16 = 51457-9, Stainless Steel, 0-20 ppm 000 = No Sensor selection if Sensor 1 is not equal to C00 (Universal Gas HC head sensor or Universal Gas head sensor), D## = Digital Sensor selection only if Sensor 1 = R## or D## (IR400 or Digital Sensor) Codinq/System Limitations Gas Detedion System: mair' transm tter + one Universa' Gas HC (Combustible Pass ve Sintered) sensot head or one Universal Ga: H2S (Toxic - Passive Sintered) sensor head (one sensor maybe connected tc one Jundion Box) (cemented) Ex db IIC T4 Gb Iamb: -40oC < Ta < +70oC (flanged) Ex db IIB+H2 T4 Gb Iamb: -40oC < Ta < +70oC Ihe coding of any attached sensor limits the coding of the transmitter/ system. Date: 08 January 2018 Form 9530 Issue 1 Page 5 of 8 Hawarden, CH5 3US, United Kingdom Tel: +44 (0) 1244 670900 Fax: +44 (0) 1244 68'1330 Ema l: ukinfo(ôcsaqroup.org Web: \,ww.csagroupuk.org

srra 55000 Gas Monitor flxed gas detection system IEC Ex SIR 17.0016X Issue 0 CSA The 55000 Junction Box: lunction Box enclosure are shown below: 55000 Junction Box leouioment) Model reference Description Codinq/Svstem Limitations 324240-L 55000 Junction Box; Stainless Steel, IIB + H2 (flanged/non-cemented) Box only, wìthout a sensor db IIB+H2 T6 Gb 324240-2 55000 Junction Box; Aluminium, IIB+H2 (flanged/non-cemented) tb IIICT85.C Db na IIC T6 Gc -55oC<Ta<+75oC With one Dig tal Sensor conneded tb IIIC T85.C Db -55oC<Ta<+60oC With one 1R400 connected tb IIIC 100.C Db -55oC<Ta<+75oC With one Universal Gas HC (Combudible Sintered) or one Universal Gas Passive Sintered) conneded - db IIB+H2 T4 Gb 40oC<Ta<+70oC 324240-3 ;5000 Junction Box; Stainless Steel, IIC (cemented) 324240-4 i5000 Junction Box; Aluminium, IIC (cemented) coding of any attached sensor of the box. Box only, without a sensor db IIC T6 Gb tb IIICT85.C Db na IIC T6 Gc b: -55oC < Ta < +75oC With one Digital Sensor connected db IIC T5 Gb tb IIIC T85.C Db -55oC<Ta<+60oC one 1R400 connected tb IIIC 100.C Db -55oC<Ta<+75oC one Universal Gas HC (Combustible Sintered) qone Universal Gas - Passive Sintered) conneded db IIC T4 Gb -40oC<Ta<+70oC coding of any attached sensor cod of the nction box. Date: O8 Januara 2018 Form 953O Issue 1 Page 6 of I Tel: +44 (0) 1244 670900 Fax: +44 (0) 1244681330 Email: ukinfo@csagrouo.org Web: www.csagroupuk.org

IEC Ex SIR 17.0016X Issue 0 srra I The Digital Sensor: Model cod Model reference \-5K-SENS-arÞ.c-ée on the sensor enclosure are Diqital Sensor, oas sensor (eouipment) Description Digital Sensor (combustible); where the following applies aa is for Gas Type: 01 = No Sensor (sensor body w/blank element) 65 = Combustible,0-100% LEL- Methane 66 = Combustible,0-100% LEL- Propane ö is for Material type 0 = Stainless Steel 1 = Aluminum c is for the listed Approval: A = ATEX/IECEx d is for Sensor Body: 0 = No Sensor Body 1 = 3/+" NPT 2=M25 e is 0 = Not relevant to cedification Digital Sensor (toxic); where the following applies aa is for Gas Type: 01 = No Sensor (sensor body w/blank element) 10 = Carbon Monoxide, 0-100 ppm 11 = Carbon Monoxide,0-500 ppm 12 = Carbon Monoxide, 0-1000 ppm 14 = Carbon Monoxide, Hydrogen Resistant 0-100 ppm 16 = oxygen, 0-25% 20 = Hydrogen Sulfide,0-10 ppm 21 = Hydrogen Sulfide, 0-50 ppm 22 = Hydrogen Sulfide, 0-100 ppm Þ is for Material type 0 = Stainless Steel 1 = Aluminum c is for the listed Approval: A = ATEX/IECEx d is for Sensor Body: 0 = No Sensor Body 1 = 3/+" NPT 2=M25 e is 0 = Not relevant to ceftification Codinq :x db IIC T5 Gb -x tb IIIC T85'C Db l-amb: -55oC < Ta < +60oC The IR400 Sensor: Model on the sensor IR400 oas sensor (equipment) Model reference Description Coding IR4OO Detector/ Sensor (combustible); provides a 4-20m4 output with r4odbus or optional Had output lx db IIB+Hz T5 Gb lx tb IIIC T100'C Db Iamb: -60oC < Ta < +75oC Date: 08 January 2018 Form 9530 Issue 1 Page 7 of 8 Tel: +44 (0) 1244 670900 Fax: +44 (0) 1244681330 Email: ukinfo@csagroup.oro Web: www.csagroupuk.org

IEC Ex SIR 17.0016X Issue 0 slra The Universal Gas (passive sintered) sensors HC & H2S Sensor Heads, models no. 11159 (HC) and 51457 (H2S): Model the are below: Model reference 11159-1 11159-2 1 1 1 59-8* 11159-11 1 1 1 59-21 1 1 1 59-8Lx sensor Pass ve ( with Modbus or optional Hart output. provides a 4-20m4 db IIC T4 Gb mb: 40oC S Ta < xexduded from the combustible gas detection peformance approval (60o7e-29-1)) 5L457-r 57457-5 5t457-9 51457-LL s1457-51 5t457-9L sensor Passive Si ntered (Toxic); provides a 4-20m4 output Modbus or optional Haft output' Date: 08January 2O18 Form 953O Issue 1 Page 8 of I Sira Gertification Service Tel: Fax: Email: Web: +44 (0) 1244 670900 +44 (0) 1244 681330 ukinfo@csagroup.org wvw.csagroupuk. org