ASPHALT STORAGE TANKS

Similar documents
HEATEC PRODUCTS AND SERVICES THAT EXCEED YOUR EXPECTATIONS

HEATEC POLYMER BLENDING SYSTEMS

Full Product Line. Products for concrete, asphalt &, energy. CEI Enterprises

Helical Coil Heaters. Hot Oil Heaters Booster Heaters. CEI Enterprises

HEATEC PRODUCTS AND SERVICES FOR THE FOOD INDUSTRY

Concrete Applications

HEATEC ASPHALT TERMINALS

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

Industrial Applications

T A B L E O F C O N T E N T S

FT900BD FLIGHT-TYPE DISHWASHER

STEPP SRM 10x120(Asphalt Recycler) SPECIFICATIONS. SRM 10x120 Self Loading

Concrete Plants ASTEC. Roller Compacted Concrete and Cement Treated Base

SIOUX Water Heaters SIOUX WATER HEATERS. Hybrid Water Heater PWP Water Heater M-1

DM 45 (40-60 TPH) ASPHALT DRUM MIX PLANT - DM 50 (60-90 TPH) I TECHNICAL SPECIFICATIONS DM 60 ( TPH) COLD AGGREGATE FEEDER.

Drum Mix facility A schematic diagram of the components in a typical drum mix facility is shown in the figure below.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

E-Z SERIES II 1500 DPSB MELTER APPLICATOR WITH DOUBLE PUMP; DIESEL-FUELED

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Models. Options. Standard Features. LoH 2 O

FT900S FLIGHT-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

Bid Specifications for Thermo-Lay model UD /4 yard truck mounted machine with hydraulic bins & roller DIMENSIONS: Body:

SIOUX WATER HEATERS. Hot Water for Cold Weather Concrete Production. Better Concrete Higher Profits. Sioux Water Heaters and Steam Generators

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER. Gathering cum slinger conveyor 500 mm x 7.

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

SECTION STEAM CONDENSATE PUMPS

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

Packaged Steam Fired Water Heater

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

PRE-BATCHER UNIT DRYER UNIT. Model: RM 350. Year of construction: Composed of:

Rental Boiler Specifications (Nebraska Boiler)

FT900 FLIGHT-TYPE DISHWASHER

CL64T INDUSTRIAL TOTE WASHER

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

GIRTON CABINET WASHER MODEL 794A

C44A/C44AW DISHWASHER

Electric Submersible Pumps

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

MAGNUM MAX ASPHALT PLANTS

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

Suggested Specifications Prestige Excellence 110

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

VENTLESS DOOR-TYPE DISHWASHER

Standard Features. Performance/Capacities

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

FUEL-FIRED VERTICAL TUBELESS BOILERS

PACKAGED COMMERCIAL WATERTUBE BOILERS

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Originators of the Flexible Water Tube design

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

Burner Comparisons. Typical Competitor s Burner

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

BuildingName The Description of the Project P DOCUMENTS

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

Conventional Thinking. Master Series Convection Ovens.

1.1 This section applies to air handling units for HVAC Systems.

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Thermal Fluid Heaters

Fuel-Fired Vertical Tubeless Boilers

D. TURBO BLOWER 1.) Turbo fan type 2.) 40 HP motor

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

ASME Packaged Indirect Fired Water Heater

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

Silhouette. Feedwater Heater. Boiler Feedwater

SECTION DOMESTIC WATER HEATERS

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Revitalize Building Mechanical Systems (4619)

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

Hoffman Specialty Pump Products

RA Series Glasteel Reactors

OFICINA COMERCIAL: Núñez de Balboa, MADRID Tel: (34) Fax: (

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

Our Purifier systems

Jethwa Automatic Can Equip. Co. An Export Award Winning ISO 9001 Quality Certified Company

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS

BASIL 6000 TUNNEL CAGE WASHER

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

12711 TOWNEPARK WAY / LOUISVILLE, KY / / FAX

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

POWERFUL CUSTOMIZED SOLUTIONS UNMATCHED QUALITY

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

TECHNICAL. Series 18. Pump Packages

Asphalt plants Soil stabilization plants Cold asphalt plants Concrete plants

THE HK500, HK300 & HK150 MOBILE GLYCOL HEATING SYSTEM

INSTANT CHILLER. Chester-Jensen Co., Inc. Unit Construction and Short Gas Flow

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

JCseries EVAPORATIVE CONDENSER. engineering data

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Wheelbarrow Mixer Operations Manual

FAS Fresh Air Supply Units

Transcription:

ASPHALT STORAGE TANKS HEATEC AN ASTEC COMPANY

THERMO-GUARD is the trademark we use to distinguish our current line of vertical asphalt storage tanks. Heatec Thermo-Guard tanks have features that cut heat loss to an absolute mimimum at a reasonable cost. The tanks are usually built to order and can be configured to suit your exact needs. Many options are available, including the components for mixing. Advantages of vertical tanks Vertical tanks minimize oxidation of the asphalt because the surface area of the asphalt in contact with air inside the tank is much smaller than in horizontal tanks. This is especially important for PMAC (polymermodified asphalt cement), which oxidizes faster because it is maintained at higher temperatures. Another advantage of a vertical tank is the minimal ground area it occupies. Vertical tanks have smaller footprints than horizontal tanks. You can put four vertical tanks in the ground space occupied by a single horizontal tank. Insulation The amount of insulation used on Heatec vertical tanks sets them apart from the competition. More insulation means less heat loss. We fully insulate all tank surfaces. The top bulkhead has a double-wall that encloses 6 inches of fiberglass insulation. Outer surfaces of the side walls also have 6 inches of fiberglass insulation. Unlike other manufacturers, we insulate the tank bottom. Its inner surface has 3-inch foam glass insulation with a metal cover to protect the insulation. This feature alone results in a significant reduction in heat loss. The difference in heat loss of our 30,000 gallon vertical tank and one of our competitor s tanks is amazing. Theirs has no insulation on its bottom and only 4 inches of insulation on its top and sides. Theirs will loose 2.582 billion (2,582,000,000) Btu per year more than ours in 20 years! That is equal to 19,517 gallons of No. 2 fuel. Some tanks only have 3 inches of insulation and lose even more heat. 1 2 VERTICAL TANKS 3 4 Four 20,000 gallon Thermo- 1 Guard asphalt tanks (ivory), a 13,000 gallon fuel tank, and a 20,000 gallon fuel tank. Standardized piping simplifies 2 installation of multiple or additional tanks. Heatec fabricated piping makes installation even easier. Heating costs can be reduced 3 by insulating asphalt piping and flanges. This control panel centralizes the operation of actuated 4 valves. It has status lights so you know which valves are open, and which are closed, an important feature for eliminating errors. 2

Fast heating Thermo-Guard tanks heat faster than competitive tanks. That s because our tanks have two to three times the amount of heating surface normally provided on other tanks. We put two layers of highly-efficient finned heating coils in the bottom. When in use hot oil flows through the coils to heat the material in the tank. The time it takes to raise the temperature of asphalt is related to the amount of heating surface. For example, suppose you get a tanker load (6,000 gallons) of asphalt that needs to have its temperature raised only 10 degrees, from 290 to 300 F. Our tank can do the job in only 20 minutes. Tanks with less heating surface will take longer. Long waits for AC to reach tempearture can disrupt your work flow. The table on the right compares times for competitor tanks and different temperature increases. PMAC Thermo-Guard tanks provide a better mixing, heating and storage solution for PMAC than competitive tanks. To achieve proper blending of PMAC, the virgin asphalt is heated to temperatures higher than normal. So, insulation is more important than ever. And design of the mixing system is just as important. MIXER MOTOR WITH GEAR REDUCER AND DRIVE Time to raise the temperature of a 6,000 gallon load of asphalt Temperature Increase Heatec 20,000 gallon vertical tank 1,100 sq ft heating surface Thermo-Guard vertical asphalt tank with handrails, caged ladder, level gauge board and mixer for polymer-modifed asphalt cement. Competitor A 20,000 gallon vertical tank 292 sq ft heating surface Competitor B 20,000 gallon vertical tank 575 sq ft heating surface 290 F to 300 F 20 minutes 56 minutes 32 minutes 280 F to 300 F 38 minutes 107 minutes 60 minutes 340 F to 350 F (PMAC) 39 minutes 114 minutes 62 minutes 330 F to 350 F (PMAC) 70 minutes 207 minutes 113 minutes Based on a hot oil temperature of 400 F with a flow rate of 50 gpm Interior view of tank shows mixer, heating coils, baffle, float for gauge board, internal piping and manhole. SYMETRICAL FLOW 3 O.D. SHAFT BAFFLE AND TWO PIPES CREATE EXTRA TURBULANCE IMPELLER BLADES 4 LONG 6 WIDE ONLY MINOR STAGNATION Flow patterns in a Thermo-Guard vertical asphalt tank with mixer. Our mixing system keeps the polymers in suspension to prevent them from separating from the virgin asphalt. The number, size, pitch, location and rotational speed of the impeller blades are key factors in maintaining mixture consistency. These tanks have aluminum skin with an embossed natural finish. Moreover, the baffle and piping are carefully arranged to keep material from hugging the tank wall and to minimize stagnation zones (see illustration at left). The mixer has a 7.5 hp motor with a totallyenclosed, fan-cooled (TEFC) housing. This housing minimizes hazards in the event any These tanks have aluminum skin with an Astec ivory paint finish, which is baked-on for durability. These tanks have aluminum skin with an Astec brown paint finish, which is baked-on for durability. fumes escape the tank. The mixer has a turnover of 5,593 gallons per minute. Its large 3-inch mixing shaft has impellers at two levels for increased efficiency. The impellers run at 42 rpm. 3

Overflow protection All of our vertical tanks offer protection against accidental overflow. A proximity switch mounted atop the tank can be wired to automatically shut off the unloading pump. The switch is activated magnetically by a short pipe attached to a float. It will automatically shut off power to the unloading pump when the asphalt lifts the float to a predetermined level. (See photos.) An optional gauge board or radar level sensor can be used as the primary shutoff control so that the proximity switch becomes a backup. Shell and skin The tank has a steel shell of welded construction. The outer skin is aluminum, requiring virtually no maintenance. We offer skin in an embossed natural finish. We also offer the skin with a baked-on painted finish, either Astec ivory or Astec brown. Decals showing the Heatec name and logo are included. Other color finishes, stripes and decals with your name or logo are available by request. Temperature control Temperature control is achieved by a temperature sensor, a controller and a three-way valve. The valve controls flow of hot oil to the tank coils. The valve opens and closes in response to the controller to maintain the stored asphalt at set temperature. Heating is automatically shut off before the asphalt level drops below the tops of the heating coils. Piping and pipe insulation Connections for piping are standardized to simplify installation. This is particularly useful when installing multiple tanks. It also makes it easier for you to add new tanks to your facility as it grows. Heatec-fabricated piping is also available, making installation even easier. Significant savings are possible by insulating asphalt and hot oil piping. For example, one inch of insulation on jacketed 4 asphalt pipe and flanges could save over 21,756 gallons of No. 2 fuel a year per 100 of pipe! Power-actuated valves Power-actuated valves, such as the ones pictured earlier, are optional. They allow centralized control of tank fill, supply and return functions. A centralized control panel with status lights reduces the liklihood of operating errors. Moreover, when the tanks Key Characteristics of Vertical Tanks MODEL TAV-10 TAV-15 TAV-20 TAV-25 TAV-30 TAV-35 Capacity (gallons) 10,000 15,000 20,000 25,000 30,000 35,000 Heating Surface (sq. ft.) 550 550 1100 1100 1100 1100 Tank Height (ft.) 16 11 24 11 30 11 38 11 44 11 50 1 Tank Diameter (ft.) 11 11 11 11 11 11 11 11 11 11 11 11 Weight (lbs) 17,825 21,025 23,625 26,625 28,861 30,905 Capacities shown are nominal capacities. Handrails add 3.5 feet to the height of the tank. Weight shown includes ladder and handrails. Mixers add from 1,260 to 1,884 lbs. Controller for setting temperature of the tank. Temperature sensor and capillary tube for controller. Dial thermometer provides confirmation. Actuator for 3-way hot oil valve. 4 High-level proximity switch cuts off fill pump to prevent overflow. Optional pressure transmitter indicates liquid level. are being filled, the valves are controlled by the plant operator, who is less likely to make errors than truck drivers who may set manually operated valves at the tanks. Options Tanks larger than those listed are available by special order. Tanks manufactured to Float inside the tank for high-level proximity switch. Optional sampling valve for taking samples of AC. Optional fume condenser reduces blue smoke emissions. meet UL142 specifications and stamped to show compliance are also available. Tanks for blending are available with load cells and legs. An electric heating system is also available in lieu of heating coils. Pressure transmitters that indicate liquid level and many other options are available.

450 400 500 350 550 300 600 250 650 200 700 Degrees F TANK INCLUDES OPTIONAL COMPONENTS RADAR SENSOR UNIT HIGH-LEVEL PROXIMITY VENT CONDENSER HANDRAILS MIXER GEAR BOX CAGED LADDER MANHOLE WITH HINGED COVER 6 FIBERGLASS INSULATION BULLS EYE GAUGE BOARD EMPTY-LEVEL GAUGE BOARD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 FLOAT FOR PROXIMITY SKIN 6 FIBERGLASS INSULATION 1/4 STEEL SIDE- WALL MIXING BAFFLE VENT/OVERFLOW PIPE FILL PIPE MIXER SHAFT WITH IMPELLERS DIAL THERMOMETER UE CONTROLLER 20 FLOAT FOR GAUGE BOARD MANHOLE WITH BOLT-ON COVER GAUGE BOARD FULL-LEVEL 21 22 23 24 25 26 27 28 29 APOLLO ACTUATOR 3-WAY HOT-OIL VALVE HEATING COILS 3 FOAMGLASS INSULATION Revised 9-21-04 5

THE HELI-TANK TM unit combines a hot oil heater with a heated asphalt storage tank. Available in six different sizes with capacities from 10,000 to 35,000 gallons. Numerous options are available. Heating coils The storage tank has serpentine heating coils. Liquid asphalt in the tank is heated by hot oil flowing through the coils. The coils are formed into three layers, each with ten coils. Coils are made from rugged 2-inch schedule 40 seamless pipe and run the full length of the tank or compartments. The accompanying table shows surface areas of the heating coils in each tank model. Details Temperature controls are the same as those on vertical tanks. Tank walls are made from A-36 steel plate. Tank heads are also steel, flanged and heavily reinforced with channel stiffeners. Access ladders are provided both inside and outside the tank. Tanks feature the same type of overflow protection described earlier for our vertical tanks. Tanks are covered with an aluminum skin and six inches of fiberglass insulation. Standard skin has an embossed natural finish. Other finishes and colors are optional. Storage tank options Internal bulkheads are optional. They divide the storage tank into compartments, which can be used for different grades or types of liquid AC, for fuel or for additives. The COMBINATION TANKS Heli-Tank portable asphalt tank with multiple-circuit hot oil heater, two storage compartments and mounting plates for mixers. Heli-Tank unit with optional fuel compartment, calibration tank and asphalt metering package. bulkheads are double-walled and insulated. Various combinations of heating coils and controls can be furnished. Hot oil heater The standard hot oil heater for Heli-Tank units is a Heatec Model HCS-100. Other models are optional. The heater can be ADDITIVE TANK LEVEL INDICATOR AND FLOAT INSULATION INSULATED BULKHEAD HIGH- LEVEL PROXIMITY HOT OIL HEATER UNLOADING PUMP METERING PACKAGE RUN-AROUND VALVE HELI-TANK FEATURES WITH OPTIONAL COMPONENTS HEATING COILS MIXER SHAFT & IMPELLERS FUEL TANK PLATE FOUNDATION 6

used to heat another coil tank, an asphalt metering package and liquid asphalt lines. When furnished with an optional manifold and auxiliary pump, the heater can also heat silo cones, traverse conveyor, and a drag conveyor. The heater has a highly efficient helical coil. Coils are built to ASME standards and can be code-stamped as an option. Coil has a 5-year warranty for HC-series heaters (3 yr. for HCS). Coils are stitch-welded to eliminate gaps between the turns so heated gases can t shortcircuit and waste energy. Optional STACKPACK economizers further increase heater efficiency. Heaters include insulated heat chamber, centrifugal pump and expansion tank. A low-maintenance burner and controls are also included. Standard burners use No. 2 fuel oil. Optional burners are available for natural gas or combination gas/oil. Model Versions for polymers Special versions of the Heli-Tank are available for use with modified asphalt. They heat and store either PMAC (polymer-modified asphalt cement) premixed at asphalt terminals or asphalt cements that incorporate GTR (ground tire rubber) mixed at the hot mix plant. Both versions maintain the PMAC at higher than normal temperatures. Pump and piping systems are oversized because PMAC has a higher viscosity than virgin asphalt. These special versions use motor-driven mixers to keep material in suspension. The mixers are mounted in the top of the tank and spaced for optimum mixing. Foundation option Optional steel plate foundations with hand cranks make set-up easy. They can be cranked down in minutes, drastically reducing set-up time and eliminating the need for cribbing. Capacity (gallons) Key Characteristics of Heli-Tanks Heating Surface Length Height Axles 7 Hot oil heater Foundations (optional) Weight (pounds) HT-10P 10,000 231 sq ft 29 0 14 3-1/2 Single HCS-100 3 29,800 HT-15P 15,000 380 sq ft 37 0 14 3-1/2 Single HCS-100 3 37,200 HT-20P 20,000 529 sq ft 48 0 14 3-1/2 Tandem HCS-100 4 46,800 HT-25P 25,000 679 sq ft 56 0 14 3-1/2 Tandem HCS-100 4 54,980 HT-30P 30,000 828 sq ft 64 6 14 3-1/2 Triple HCS-100 5 63,110 HT-35P 35,000 977 sq ft 72 0 14 3-1/2 Triple HCS-100 5 78,240 Capacities shown are nominal capacities. Weights are approximate and include HCS-100 heater plus optional plate foundations (1,000 lbs each), metering package (1,550 lbs) and unloading pump package (1,050 lbs). Rear frame extension adds approximately 7 feet to overall length. Internal view of Heli-Tank shows heating coils, level indicator and float, access ladder and mounting plate for mixer. Piping options: 3 or 4 inch piping AC lines with hot oil jackets Rigid AC lines with 12-degree ball joints Insulation on hot oil and AC lines Piping to drum mixer and other tanks 1-1/2-inch hot oil jumper lines Heater on this Heli-Tank is fitted with optional STACKPACK economizer to boost efficiency and lower fuel consumption. Model Chassis options Budd wheels, spring suspension and either single, tandem or triple axles are optional. Quad axles and air bag suspension are also available. Fuel tank option A 400 650-gallon compartment can be built into the gooseneck of the chassis for storage of No.2 fuel for the burner. Output Btu/hour HOT OIL HEATERS Fuel usage Recirculation Pump Expansion Tank No.2 gph Gas cfh gpm gallons SINGLE CIRCUIT HEATERS HCS-70 700,000 6 910 100 100 HCS-100 1,200,000 10 1,560 100 175 HCS-175 2,000,000 17 2,600 150 280 MULTI-CIRCUIT HEATERS HC-120 1,200,000 10 1,560 100 175 HC-200 2,000,000 17 2,600 150 280 Additive tank option A 2,000 gallon additive tank can be built onto the rear of the main tank, overhanging the pump system. It is heated and insulated. Metering package option The optional metering system uses two positive displacement pumps. One is an AC supply pump, the other a metering pump. The metering pump responds only to the actual

Other options flow of AC and is much more reliable than systems that merely sense rotations of the supply pump. The system corrects flow rate to allow for temperature variations. Mass-flow type meters are also available. An optional pump, motor, and strainer system unloads AC tankers. The system can be piped so it also unloads the Heli-Tank. Other options include a sock filter for the hot oil line, fuel preheater mounted on the rear frame extension, radar liquid level gauges, fold-down handrails, a 7-day time clock, and high-low AC level alarm. An optional telephone dialer automatically reports heating problems when the plant is unattended. Optional unloading pump for unloading AC tankers. Optional metering package on rear frame extension. Optional calibration tank on rear frame extension. Optional fuel preheater on rear frame extension. Optional power-actuated valves for AC lines. Optional insulation on hot oil/ac lines. Unloading pump option 8 Optional steel plate foundations.

HEATEC WELBILT tanks are horizontal storage tanks that include heating coils for hot oil. They are normally used to heat and store liquid AC, but can be used for other materials, such as heavy fuel oil. They come in seven different sizes with capacities from 10,000 to 40,000 gallons. Numerous options are available. Portable models have a chassis for highway travel similar to the chassis of the Heli-Tank. Stationary models have saddles that rest on foundations or on the ground. Standard skin is aluminum with an embossed natural finish. Astec ivory or other color finishes are optional. An 18-inch wide area along the top of the tank is reinforced to allow workers to walk on it without damaging the skin. End wall skins are made of steel for extra ruggedness. Special features Welbilt tanks have the same type of overflow protection described earlier for our vertical tanks. A manway is located in the top of each compartment. An access ladder is provided on the outside of the tank and inside each compartment. Each compartment also has a combination vent and overflow pipe. A 3-inch plug valve in the bottom of each compartment allows it to be completely drained, HORIZONTAL TANKS WELBILT stationary horizontal tank. WELBILT portable horizontal tank.. LADDER HIGH-LEVEL PROXIMITY INSULATION FUME CONDENSER INSULATED BULKHEAD LEVEL INDICATOR AND FLOAT MANWAY MIXER SHAFT WITH IMPELLERS OVERFLOW PIPE HEATING COILS SADDLE KEY HORIZONTAL TANK FEATURES AND OPTIONS 9

which is necessary when polymer asphalts are used. Temperature controls Temperature controls are the same as those described for vertical tanks. Tank options Internal bulkheads are optional. They divide the tank into compartments, which can be used for different ACs, heavy fuel and additives. Bulkheads are double-walled, insulated and can be placed to divide the tank into a variety of sizes. Various combinations of heating coils and controls can be furnished. Heater option The tanks are compatible with virtually any hot oil heater, such as the Heatec HC/HCS series. As an option, one of these heaters can be installed on an extension to the tank. Unloading pump option An optional pump, motor, and strainer system unloads AC tankers. The system can be piped so it also unloads the tank. Mixer options Mixers for PMAC similar to those used in vertical tanks can be factory-installed in new tanks. We recommend the arrangement shown in the drawing at the right. Other options Other options include radar level gauges, metering package, gauge boards, chart recorders, ball-joint piping (for relocatable plants), high-low AC level alarm, fume condensers, air-operated valves, and more. Model Capacity (gallons) MANWAY Key Characteristics of Stationary Horizontal Tanks Heating Surface Coil Capacity Length Height Width MIXERS IN IDEAL LOCATIONS Weight (pounds) TA-10 10,000 231 sq ft 65 gal 18 4 11 11 11 1-1/2 10,960 TA-15 15,000 380 sq ft 107 gal 26 4 11 11 11 1-1/2 14,931 TA-20 20,000 529 sq ft 148 gal 34 4 11 11 11 1-1/2 18,894 TA-25 25,000 679 sq ft 190 gal 42 4 11 11 11 1-1/2 22,912 TA-30 30,000 828 sq ft 232 gal 50 4 11 11 11 1-1/2 26,625 TA-35 35,000 977 sq ft 274 gal 58 4 11 11 11 1-1/2 31,160 TA-40 40,000 1126 sq ft 316 gal 66 4 11 11 11 6-1/2 35,200 Capacities shown are nominal capacities. Model Capacity (gallons) Key Characteristics of Portable Horizontal Tanks Heating Surface Coil Capacity Length Height Width Weight (pounds) TA-10P 10,000 231 sq ft 65 gal 27 1 14 3 11 1-1/2 15,100 TA-15P 15,000 380 sq ft 107 gal 37 1 14 3 11 1-1/2 29,600 TA-20P 20,000 529 sq ft 148 gal 46 1 14 3 11 1-1/2 34,600 TA-25P 25,000 679 sq ft 190 gal 53 6 14 3 11 1-1/2 44,600 TA-30P 30,000 828 sq ft 232 gal 58 1 14 3 11 1-1/2 52,950 TA-35P 35,000 977 sq ft 274 gal 70 3 14 3 11 1-1/2 71,250 Capacities shown are nominal capacities. An 18-inch wide area along the top of the tank is steel-reinforced to allow workers to walk on the tank without damaging the skin. This feature is standard on all horizontal asphalt tanks, including Heli-Tank. ONLY MINOR STAGNANTION This arrangement of mixers provides better mixing for PMAC than a pump and spraybar. Specifications subject to change without notice Publication 2-06-173, Revised 6-2012 HEATEC,INC. an Astec Industries Company 5200 WILSON RD CHATTANOOGA, TN 37410 USA 800.235.5200 FAX 423.821.7673 heatec.com