Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Similar documents
Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Remote Chexit Module (RCM) System. General Information

Beacon 800 Gas Monitor Operator s Manual

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

DE5300 Delayed Egress System. General Information

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Installation Guide for models:

Installation Guide for models:

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Beacon 110 Gas Monitor Operator s Manual

CA5000 Liquid CO 2 Freezer Backup System

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Series. Access Power Controllers. Installation Guide

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Installation/Owner s Manual Models 1504 / 1506

Addendum for STI-6406 with Dual Access Control

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

VX SERIES Wireless Thermostat with Occupancy Sensor

EVO192 v3.0 Fire and Burglary What s New

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

RFID Card Access Control Unit. Operating Instructions

E-PLEX 5x70 Series Stand-Alone Access Controller. Installation Instructions

Beacon 410A Gas Monitor Operator s Manual

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

AXS Strikemaster Engineering Manual

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

OPTICAL TURNSTILE SYSTEM

Model 4001 Series Single Channel Controller

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Installation, Operating and Maintenance Manual

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Instruction Manual WARNING

AirGard 385 Fume Hood Monitor

Exit Stopper. STI-6400 Series

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Strikemaster ES Engineering Manual

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

Controllers. Instruction Manual WARNING

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

MODEL B2 INSTALLATION MANUAL

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

CORNELL Emergency Response Systems

GAS MONITOR Model Model

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

GENERATOR SELF-TEST VERIFIER (GSV300) INSTALLATION INSTRUCTIONS

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

DWA2000. WAAS Annunciator. Installation and Operations Manual. Rev 1.1 December 2014

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

WSK300 Multifunction Wall Control

SPECTRA 1727 USER S GUIDE

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

EXTINGUISHING AGENT RELEASE MODULE

MBCE-110/230UV Flame Sensor Module

Installation Instructions

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Exit Stopper. STI-6400 Series

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

FLCH4R Garage and Utility Electric Heater

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

KFP-CF Series Operation Manual

Beacon 200 Gas Monitor Operator s Manual

5000 SERIES 8 ZONE INSTRUCTION MANUAL

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE.

Transcription:

Crypto-Lock Model CC-8521B Updated 7/17 Access Control System INSTRUCTION MANUAL MONITEQ, Inc.

2

TABLE OF CONTENTS 1. INTRODUCTION..4 2. SPECIFICATIONS.....6 3. SUPPLIED EQUIPMENT.. 6 4. FUNCTIONS OF CONTROLS AND INDICATORS... 7 4.1 KEYPAD 4.2 CONTROL UNIT 5. INSTALLATION AND POWER SUPPLY SETTINGS... 8 5.1 GENERAL 5.2 INSTALLATION 5.3 POWER SUPPLY SETTINGS 6. PROGRAMMING 10 6.1 GENERAL 6.2 THE PROGRAMMING MODE 6.3 INITIAL SETTINGS 6.4 PIN MANAGEMENT 6.5 DOOR MONITORING OPEN DURATION ANTI-FOLLOW DOOR PROPPED ALARM FORCED DOOR ALARM 7. OPERATION...12 8. KEYPAD INSTALLATION TEMPLATE......13 3

1. INTRODUCTION The Crypto-Lock Model CC-8521B is a versatile, easy installed and operated single door access control system. It provides reliable, secure keypad access control using a single 3, 4, 5 or 6-digit PIN code for all users. It can be used with virtually all magnetic locks and electric strikes and can be used to operate both a magnetic lock and an electric strike on the same door. The system, pictured in Figure 1-1, includes a built-in 12VDC and 24VDC power supply to power electric strikes and magnetic locks, eliminating the need for a separate power supply unit. It provides the voltages and currents required to reliably open standard locking devices including heavy duty locks such as Von Duprin* rim latch retraction units and Sargent & Greenleaf BRUTE* electric locks that require high in-rush currents. The power supply includes a battery charging and monitoring circuit that automatically maintains batteries in a fully charged condition and activates audible and visual warnings when the charge level is low. Two 12V, 7AH sealed lead acid batteries (not included) can be housed within the Control Unit enclosure. The time duration during which the lock remains released after entry of the valid PIN is adjustable from 1 to 60 seconds. An invalid PIN penalty feature provides for ignoring all keypad entries for 5 to 60 seconds after an invalid digit is entered. This greatly reduces the possibility of gaining access by guessing PIN codes, and is particularly effective when shorter PIN lengths are used. The Keypad unit includes a green LED that illuminates when the lock is released. The # button on the Keypad activates an annunciator in the Control Unit and also generates output signal for activating an external visible or audible device. Installation and set-up are readily accomplished using the wiring diagram affixed to the inside of the enclosure 4 Figure 1-1, The CC-8521B Control Unit and keypad. door and also contained in this manual. A slide switch sets the lock output voltage (12V or 24V). A programming mode (which can only be activated from within the Control Unit) allows authorized personnel to set the PIN and other functions (see Table 6-1) using the Keypad. A typical installation of the CC-8521B is illustrated in Figure 1-2. *Von Duprin is a registered trademark of the Ingersoll- Rand Company; Brute is a registered trademark of Sargent & Greenleaf, Inc.

Features: 3, 4, 5, or 6-digit PIN Adjustable open Block after invalid * PINs Door Propped Alarm * Forced Door Alarm * Anti Follow Through * Built-in lock power supply with battery back-up capability * Built in Door Bell function Versatile lock power : Fail safe, fail secure or both 12VDC or 24VDC @ 2A, 16A In-rush * Holding current limiting protects lock * Alarm and Annunciator Output CC-8521B CRYPTO -LOCK Stand-by Batteries Door switch Magnetic lock (fail-safe) Release Button Keypad With Status LED Electric lock or strike (fail-secure) 115/230 VAC, 50/60Hz Figure 1-2, Typical Application of the Model CC-8521B Access Controller 5

2. SPECIFICATIONS Power required: 115 VAC, 50 or 60 Hz, 25W Output: 12VDC or 24VDC, 2A continuous, 16A in-rush current Relay contacts: 10A, SPDT (Form C) Battery back-up: 12VDC or 24VDC, automatic transfer and charging (batteries optional, Moniteq p/n CC- BATT) Battery monitoring: Warning lamp, beeper and output signal activate when battery is low PIN code length: 3, 4, 5 or 6 digits Open duration: Adjustable, 1 to 60 seconds Penalty function: Invalid PIN attempts temporarily disable operation and can be set to sound an alarm Penalty time: Adjustable, 5 to 60 seconds, set to 60 seconds after five invalid PIN attempts Remote release input: Dry contact closure Door monitoring functions: Door propped open alarm, forced door alarm, anti-tailgating Keypad cable: 10-conductor, #22 supplied cable: 15 ft., 10-cond., #22 maximum length: 1,000 ft. Enclosure: 19 gauge steel, powder coated paint, gray color, knock-outs for conduit, and cam-lock (included), holes for padlock (not included) Dimensions: 12H x 9W x 4.5D in. Options available: CC-BATT: 12 VDC, 7AH rechargeable battery (2 required for 24VDC operation); CC-BRUTE: surface mount electric lock. 3. SUPPLIED EQUIPMENT The CC-8521B consists of two main units, the Keypad and Control Unit, and various accessories and mounting hardware to facilitate installation. The table below lists all of the items that comprise the Model CC-8521B along with a brief description of each to aid in their identification and use. QTY ITEM PURPOSE 1 Control Unit Main processor and power supply 1 Keypad with 15 cable Accepts PIN code entries 1 Manual, Crypto Lock CC-8421V2 (this manual) Installation and operating instructions 1 AC power cord Connection to AC power 2 Threaded rod, #8 X 12" Keypad mounting, thru-wall 1* Cam Lock w/ two keys Lock Control Unit door 2* Screw, slotted, Sheet metal, #6, 1/2" Hold Control Unit door closed 2* Battery cables, #18 AWG, black/red Connect batteries to Lock Driver Board 2* Fuse, 2A, Slo-Blo Spares 4* Hex Nut, #8 Keypad mounting 2* Acorn nut, #8 Keypad mounting, thru-wall 6* Lock washer, #8 Keypad mounting 2* Washer, #8, 1-1/2 in. dia. Keypad mounting, thru-wall 8* Pan head combo drive screw, #8 x 1-1/2" Keypad and Control Unit mounting 2* Bushing, black nylon, 7/8" Protects cables going into Control Unit 2* Cradle mount, nylon, adhesive back, 1" x 1" Secure wires within Control Unit 6* Tie wrap, nylon, 4" Secure cables within Control Unit 2* Vent plug, black nylon, 7/8 Ventilate Control Unit in warm environments 1 Template, Keypad mounting holes Keypad installation * Items packed in poly bag 6

4. FUNCTIONS OF CONTROLS AND INDICATORS 4.1 KEYPAD Normal Operation Mode: Keys 1 through 0: Used to enter the PIN code. # Key: Sounds an annunciator in the Control Unit and also activates a 12 VDC output signal for use with an external device. *Key: Not used Green LED indicator: Illuminates when the door is released; flashes when any key is pressed. Programming Mode: Keys 1 through 0: Used to enter programming codes. # Key: Used to terminate the programming mode. * Key: Used as a delimiter for programming codes and parameters. Green LED indicator: Programming mode: Flashes continuously Valid programming entry: Single flash Invalid programming entry: Three flashes 4.2 CONTROL UNIT PENALTY Indicator LED: Illuminates when the invalid PIN penalty feature is activated. AC POWER Indicator LED: Indicates that the system is AC powered. BATTERY Indicator LED: Indicates that the system is battery powered. OUTPUT VOLTAGE switch (24V or 12V): Selects the voltage that will operate the locking device(s) attached to the system. OUTPUT MODE: DIRECT position: Provides up to 2A of continuous holding current. LIMIT HOLDING CURRENT position: Holding current is limited to approximately 300 ma after the locking device is initially energized. This setting permits holding an electric lock or strikes open without damaging its solenoid. Note: Current limiting operates only when the OUTPUT VOLTAGE SOURCE switch is set to 24V. LOW BAT Indicator LED: Indicates that the battery is low. BEEPER: See Table 6-1, Programming Sequences F1 and F2: 24VAC power, 2A Slo Blo F3: Batteries, 2A Slo Blo F4: Lock current, 2A Slo Blo 7

5. INSTALLATION AND POWER SUPPLY SETTINGS 5.1 GENERAL Installation of the CC-8521B requires mounting the Keypad and Control Unit, connecting the Keypad, AC power, external lock, and a door switch (required to implement door monitoring functions) to the Control Unit, and installing the batteries (optional) in the Control Unit. A switch in the Control Unit is used to set the AC power input to either 115 or 230 VAC. Another switch in the Control Unit is used to set the lock voltage to either 12 or 24 VDC. Programming includes setting the valid PIN code, open duration time, invalid PIN penalty time, and options for activating door propped and forced door alarms and the anti-tailgating function. 5.2 INSTALLATION 1) Mount the Keypad approximately 36 to 44 inches above the floor on the unsecured side of the door. Use the template on page 18 to mark and drill holes. Through-wall mounting can be accomplished using the supplied #8 threaded rods, acorn nuts, hex nuts, and 1 ½ washers. Alternatively, the Keypad can be mounted using the four #8 x 1 ½ pan head combo drive screws. 2) Mount the electric lock, strike and/or magnet according to the manufacturer s instructions. 3) Mount the Control Unit on the secure side of the door in an area convenient to the door and an electrical outlet. Four #8 x 1 ½ pan head combo drive screws are provided. 4) If required, install the supplied Cam Lock on the enclosure door in the knockout hole provided for that purpose. Alternatively, if a padlock (not supplied) is to be used, remove the two 3/8 nylon plugs from the padlock holes. The padlock s shackle must first be inserted through the hole on the side of the enclosure; the door can then be closed so that the padlock hole on the door also passes over the shackle. If the door does not need to be locked, the two supplied #6 x 1 ½ screws can be used in the holes on the door edge to hold it closed. Note: All cables passing through the knockout holes in enclosure must be protected from chafing using the supplied 7/8 nylon grommets. Route all cables to avoid the space in the bottom of the Control Unit that can be occupied by batteries. Nylon tie wraps and selfadhering nylon cradle mounts are supplied. 5) Connect the Keypad to the Control Unit as shown in Figure 5-1. Fifteen feet of cable is supplied with the Keypad. The Keypad can be located up to 1,000 feet from the Control Unit using additional cable. (Requires 10 conductors, #22 or larger.) 6) Connect the electric lock, strike and/or magnet as shown in Figure 5-1. 7) If used, connect a Release Button (not supplied), and external 12VDC annunciator (not supplied), shown in Figure 5-1. Note: An internal annunciator in the Control Unit will sound when the Keypad s # button is pressed and for all alarm functions. 8) If the Door Propped or Forced Door alarm functions will be used, connect the door switch to the Control Unit as shown in Figure 5-1. 9) If used, install and connect the batteries as shown in Figure 5-1 using the two supplied battery cables. Use only 12V, 1.2 to 7AH re-chargeable sealed lead acid batteries. (Moniteq Type CC-BATT) 10) Set the AC Power switch in the Control Unit to either 115VAC or 230VAC and connect the AC Power Cord to the Control Unit as shown in Figure 5-1. 5.3 POWER SUPPLY SETTINGS 1) Set the OUTPUT VOLTAGE switch in accordance with the voltage (12VDC or 24VDC) rating of the lock(s) being used. Note: If both a magnetic lock and an electric strike/lock are used, both must have the same voltage rating. 2) Set the OUTPUT MODE switch to LIMIT HOLDING CURRENT when used with a BRUTE ELECTRIC LOCK or a similar heavy duty solenoid operated lock. Set this switch to DIRECT when used with standard electric strikes or magnetic locks. 3) Connect the Power Cord to an appropriate source of AC power and verify that the AC POWER indicator in the Control Unit illuminates. 8

BRN RED ORG GRY VIO BLU GRN YEL BLK C1 C2 C3 R1 R2 R3 R4 LED BEEP GROUND GROUND EXT. RELEASE DOOR SWITCH GROUND ANNUNCIATOR +12 VDC 0 VAC 24 VAC 12 VAC -12 BATTERY (GND) +12 BATTERY -24 BATTERY +24 BATTERY RELAY N/O RELAY N/C GROUND EARTH GROUND 115/230 HOT 115/230 NEUTRAL CC-8521B Rev.1.4 24 VDC 12 VDC OUTPUT VOLTAGE!!! CAUTION!!! SET AC VOLTAGE SWITCH BEFORE APPLYING POWER T1 PROGRAM MODE PENALTY LOW BATTERY F1 F2 BATTERY 12 VAC T3 2A SB 2A SB F3 24 VAC 2A SB F4 LOCK T4 2A SB OUTPUT MODE RELAY LIMIT HOLDING CURRENT (300mA) DIRECT POWER AC VOLTAGE SELECT SWITCH 230 115 T5 T6 AC FUSE 2A 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 1 2 3 4 5 6 7 8 910 O R G W H T O R G 1 2 3 4 R W E H D T G R N B R N G R N 1 2 3 G R N W H T B L K TRANSFORMER 1 2 3 4 5 6 7 8 9 * 0 # MONITEQ, Inc. Tel. 1-800-989-9891 Model CC-8521B Crypto-Lock NSN 6350-01-185-4505 REQUEST TO EXIT MAGNETIC LOCK Door Switch BATTERY BATTERY - + - + ELECTRIC LOCK OR STRIKE Figure 5-1, Wiring Diagram for External Devices 9

6. PROGRAMMING 6.1 GENERAL Programming includes: setting the valid PIN, open duration time, invalid PIN penalty time, and options for the door propped and forced door alarms. These settings are accessible only by first putting the Control Unit in the Programming Mode and then entering the programming sequences listed in Table 6-1 on the Keypad. Programming sequences are entered on the Keypad in the form *FC*N*, where FC is a 2-digit Function Code and N is a numeric value. Table 6-1, Programming Sequences Function Sequence Range of N Default PIN MANAGEMENT FUNCTIONS Set Defaults *00* N/A N/A Delete PIN *10* N/A N/A Set PIN *11*N* 000 to 999, 9999, 99999 or 999999 No valid PIN Penalty Time *12*N* 5 to 60 (seconds) 5 seconds Invalid PIN Alarm *13*N* 0=Off, 1=On Off DOOR MANAGEMENT FUNCTIONS Open Duration *20*N* 1 to 60 (sec.) 5 seconds Anti-Follow Through Door Propped Alarm Delay Time Door Propped Alarm Duration Forced Door Alarm *21*N* 0=Off, 1=On Off *22*N* 1 to 255(sec.)=On, 0=Off Off *23*N* 15 to 255(sec), 0=Door Closed Door Closed *24*N* 0=Off, 1=On Off 6.2 THE PROGRAMMING MODE Enter the Programming Mode by pressing the PROGRAM MODE button inside the Control Unit. The red PROGRAM indicator lamp in the Control Unit and the green indicator lamp on the Keypad will both begin to flash, verifying that the Programming Mode is active. To exit the Programming Mode and return to the Normal Operation Mode, press either the PROGRAM MODE button again or the # key on the Keypad. The system will also revert to Normal Mode if no keys on the Keypad are pressed for 5 minutes. 6.3 INITIAL SETTINGS During a new installation or if you are uncertain as to what settings have been programmed previously, it is recommended that the default values for all PIN and Door Monitoring settings be set by entering *00* on the Keypad. 6.4 PIN MANAGEMENT 10 A new valid PIN code can be set only when the system is in the Programming Mode. To establish a new valid PIN, enter *11*N*, where N is any number containing either 3, 4, 5 or 6-digits. To delete the current valid PIN enter *10*. (This effectively disables the Keypad since no PIN entry can then be used to release the door.) The CC-8521B includes an invalid PIN penalty feature that protects against an unauthorized user gaining entry by entering successive guesses of the correct PIN. When an invalid PIN is entered, the system then ignores all further PIN entries for 5 to 60 seconds. The default value is 5 seconds. To change the Penalty Time, enter *12*N*, where N is from 5 to 60 seconds. After five successive invalid PIN entries, the penalty time is automatically reset to 60 seconds until the valid PIN is entered. This feature increases the average time it would take to successfully guess the

valid PIN and is particularly effective in protecting PINs with only 3 or 4 digits. An Invalid PIN Alarm feature sounds an alarm (three short beeps) whenever an invalid PIN is entered. This feature is disabled by default. To enable, enter *13*1*. To disable, enter *13*0*. 6.5 DOOR MONITORING The system includes a number of functions that make it possible to monitor the status of the door during operation. With the exception of the Open Duration function, these features require that a door position switch be installed on the door and connected to the Control Unit as illustrated in Figure 5-1. Open Duration: The Open Duration is the time period during which the door is released (unlocked) after either a valid PIN is entered on the Keypad or the remote release button is pressed. The default Open Duration time is 5 seconds. To change the Open Duration time, enter *20*N*, where N is from 1 to 60 seconds. Anti-Follow: The Anti-Follow mode is provided to prevent the door from being re-opened a second time during the Open Duration time period. This function is disabled by default. To enable Anti-Follow, enter *21*1*. To disable Anti-Follow, enter *21*0*. When this function is enabled the door re-locks immediately after it closes, regardless of the Open Duration setting. Door Propped Alarm: The Door Propped Alarm function sounds an alarm when the door remains open for more than a period of time from 1 to 255 seconds (Door Propped Alarm Delay Time) or until the door is closed. This function is disabled by default. To enable the Door Propped Alarm, set the Door Propped Alarm Delay Time by entering *22*N* where N is 1 to 255 seconds. To disable the Door Propped Alarm, enter *22*0*. The Door Propped Alarm Duration can be set to sound continuously either until the door closes or until a time out period expires or the door closes, whichever occurs first. Enter programming code *23*0* to set the Door Propped Alarm to sound until the door closes. To have the Door Propped Alarm sound until a time out period expires or the door closes (whichever occurs first), enter *23*N* where N is 15 to 255 seconds (Door Propped Alarm Duration). Forced Door Alarm: The Forced Door Alarm function sounds an alarm if the door is opened without being released by the system. This function is disabled by default. To enable the Forced Door Alarm, enter *24*1*. To disable the Forced Door Alarm, enter *24*0*. The Forced Door Alarm is silenced by entering the valid PIN on the Keypad or by disabling the Forced Door Alarm function by entering programming code *24*0*. 11

7. OPERATION To operate the CC-8521B, enter the valid 3, 4, 5 or 6-digit PIN code on the Keypad. When the valid PIN code is entered, the green LED on the Keypad will illuminate and the door lock will release. The CC-8521B Keypad has a built-in visitor annunciator button. Pressing the # key causes an annunciator to sound in the Control Unit. If an external sounding device is connected as shown in Figure 5-1, it will also sound when this button is pressed. If an incorrect PIN code is entered, the system will enter a penalty mode and will not recognize any digits for a time period of 5 to 60 seconds. If five successive invalid PINs are entered, the penalty time is set to 60 seconds until the valid PIN is entered. After the penalty time has elapsed, the unit will return to normal operation and entering the valid PIN code on the Keypad will release the door. If the external Release Button has been installed, it can be used by an attendant to release the lock from a location on the secure side of the door. Various alarm situations activate different sequences of sounds on the beeper in the Control Unit. If an external annunciator is connected to the system, it will sound the same sequences as the beeper in the Control Unit. Table 7-1 lists these alarm sequences and their meaning. Table 7-1, Alarm Sequences Alarm Type Alarm Sequence Silenced by: Visitor Activated by # button on keypad Invalid PIN - - - - - Five short beeps Door Propped Continuous long beeps After five short beeps Door closed or time out set by code *23*N* Forced Door - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Continuous short beeps Low Battery - - - - - Chirp every 15 seconds Valid PIN or code *24*0* Apply AC power 12

8. KEYPAD INSTALLATION TEMPLATE CRYPTO-LOCK Models CC-8421B and CC-8521B Keypad Mounting Template Keyhole (for #8 screws) 3/4" D (cable grommet) 4-5/8" Threaded inserts for 8-32 screw or threaded rod Pilot holes 3-5/8" 13

14

15

One Year Limited Warranty MONITEQ products are warranted to be free from factory defects for a period of one year from the date of shipment. The repair or replacement of a defective part shall be at the option of the factory when the product is shipped prepaid and insured by the owner. This warranty is void in cases of abuse, misuse, mishandling, modification, or repair by unauthorized persons. This warranty is given in lieu of all other warranties expressed or implied. Moniteq is not liable for incidental or consequential damages resulting from the operation or failure of this product. This warranty recognizes any and all rights you may have under appropriate state law. MONITEQ, INC. 213 Church Street Greensboro, MD 21639 Tel: 1-410-827-8870 1-800-989-9891 Fax: 1-410-827-8875 Email: info@moniteq.com Web: www.moniteq.com 16