Light Duty Commercial Electric Voltage and Wattage Conversion Instructions

Similar documents
Light Duty Commercial Electric Voltage and Wattage Conversion Instructions

CONVERSION KIT INSTRUCTIONS Commercial Electric Water heaters

CONVERSION KIT INSTRUCTIONS

Residential Upright Residential Lowboy

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

WATTS WALL-MOUNT WIDESPREAD BATHROOM FAUCET INSTALLATION

Audi-Larm Audible Alarm

DRAIN WATER TEMPERING INSTALL

Commercial Electric Energy Saver Water Heater IMMERSION AND SURFACE MOUNTED THERMOSTAT MODELS

IB 835. Installation Manual. Integrated Bidet Toilet TABLE OF CONTENTS

D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

DELEVINGNE WIDESPREAD FAUCET INSTALLATION

TARVER SINGLE HOLE FAUCET INSTALLATION

BROEG SINGLE HOLE FAUCET INSTALLATION

LUDGATE SINGLE HOLE FAUCET INSTALLATION

PAGOSA SINGLE HOLE FAUCET INSTALLATION

Parts & Material Included

EUTECTIC EC-20 OIL-FIRED WATER BOILERS/NO. 2 OIL ASSEMBLY INSTRUCTIONS EUTECTIC EC-20 ASSEMBLY GUIDE

Platen Heater Pad Replacement

V Refrigeration Module

5800 Refrigerator Compressor Capacitor/Relay Kit

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Heat Exchanger Block Replacement Instructions

HOT WATER BOTTLE BATH PART NUMBER

DRAIN WATER TEMPERING INSTALL

RYLE WIDESPREAD FAUCET INSTALLATION

KITCHEN FAUCET COS-KF222C

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

V Refrigeration Module

FLT93 Installation, Operation and Troubleshooting Guide

1500W PTC element (230V)

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Manual. Models 99168, 99169, 99170

Concepts Serving Systems

English, French & Spanish No Color

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 1000 ft. above sea level.

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

5700 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

PROPANE CONVERSION INSTRUCTIONS. Applies to: Gas-Fired, Tubular Radiant, Low-Intensity Infrared Heater

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

AUBEREE CENTERSET FAUCET INSTALLATION

TECHNICAL INSTRUCTIONS

CONTEMPORARY KITCHEN AND PREP FAUCET INSTALLATION INSTRUCTIONS

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

Panel Mounted Heat Exchangers by Dantherm, Inc.

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

569, 570, 571, 572 Series

Installation Instructions Built-In Dishwasher

HX Field Replacement Kit

Water Distiller Service Manual

MENZA CENTERSET FAUCET INSTALLATION

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

DISHWASHER INSTALLATION INSTRUCTIONS

SuperKlean Washdown Products

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

FIREPLACE INSTALLATION

EEMAX SERIES-TWO WATER HEATERS

TRADITIONAL PLP PULLDOWN FAUCET INSTALLATION INSTRUCTIONS. Model #s: 5500, 5600, 5610, 5200, 5210

TRADITIONAL KITCHEN AND PREP FAUCET INSTALLATION INSTRUCTIONS

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

TECHNICAL INSTRUCTIONS

Undercounter Refrigeration

! WARNING. Before using product, read and understand instructions.

OptiSoft Softeners Simple Install Steps 1-17

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven

Installation Instructions Air Pump

EDISON DUAL HANDLE VESSEL SINK FAUCET

Installation Instructions

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

961 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting

M5 BLUE BOY FIVE GALLON PAINT MIXER Owner s Manual

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

STONE TROUGH CONSOLE SINK

Food Waste Disposer Instruction Manual

Viking Installation Guide

AVENGER HT THERMOSTAT RETROFIT INSTRUCTIONS

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

AJ-44 Rack Conveyor Dishmachine Maintenance Instructions. Changing Conveyor Direction

Decorative Low Profile Integrated Kit

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

TRADITIONAL PLP PULLDOWN FAUCET INSTALLATION INSTRUCTIONS. Model #s: 5500, 5600, 5610, 5200, 5210

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

Installation Instructions

CAOL VESSEL SINK FAUCET INSTALLATION

LETA SINGLE HOLE FAUCET INSTALLATION

INSTALLATION GUIDE Dual Fuel Ranges

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

569, 570, 571, 572 Series

Installation & Maintenance Instructions

TECHNICAL INSTRUCTIONS

NISSAN FRONTIER INSTALLATION INSTRUCTIONS

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Installation Instructions

INSTALLATION & SERVICE MANUAL

Transcription:

Light Duty Commercial Electric Voltage and Wattage Conversion Instructions Conversion to be performed by a Qualified Service Person only. Underwriters Laboratories Inc. recognizes this procedure as herein presented and no deviation from these instructions are allowed. LDWH-6U LDWH-12U LDWH-20L LDWH-30L LE16WV LE112WV LE120WV LD-20L LD-30L LD-30R LD-40L LD-40S LD-50L LD-50S LD-65R LD-80R LD-120R LE120L LE130L LE230S LE140L LE240S LE150L LE250S LE265T LE280T LE2120T Page 1 of 8 LD-6U LD-12U LD-12UT LD-20U LD-30U LE16U LE112U LE112T LE120U 238-46411-00D 8/15

The conversion procedure outlined in the instruction manual is to be executed only by Qualified Service Personnel. Read these instructions first before proceeding with the conversion. The purpose of this instruction manual is to instruct about the changing of wattage and voltage for Light Duty Commercial Electric water heaters manufactured by Bradford White Corporation. ETL recognizes this procedure as herein presented and no deviation from these instructions are allowed. Special factory prepared kits must be used for these conversions. Below is a list of the kits that have been prepared for the various wattages and voltages. These instructions do not allow for the modification that adds or deletes the number of heating elements originally supplied with the water heater; therefore such a modification must not be attempted. Voltage and Wattage conversion kit part numbers: Element Non-Simultaneous Simultaneous Voltage Wattage Max Wattage Max Wattage 120 208 240 277 1500 1500 3000 265-46409-01 265-46409-05 265-46409-13 265-46409-16 2000 2000 4000 265-46409-02* 265-46409-06 265-46409-05 265-46409-17 2500 2500 5000 265-46409-03* 265-46409-07 265-46409-06 265-46409-18 3000 3000 6000 265-46409-04* 265-46409-08 265-46409-14 265-46409-19 3500 3500 7000 N/A 265-46409-09 265-46409-07 N/A 4000 4000 8000 N/A 265-46409-10 265-46409-08 265-46409-20 4500 4500 9000 N/A 265-46409-11 265-46409-09 265-46409-21 5000 5000 10000 N/A 265-46409-12 265-46409-15 265-46409-22 5500 5500 11000 N/A 265-46409-46* 265-46409-10 265-46409-40 6000 6000 12000 N/A 265-46409-47* 265-46409-48* 265-46409-23 * These kits contain only one (1) element. These are non-simultaneous kits only. Element Wattage Non-Simultaneous Max Wattage Simultaneous Max Wattage 380 Voltage 415 480 1500 1500 3000 265-46409-24 265-46409-41 265-46409-32 2000 2000 4000 265-46409-43 265-46409-24 265-46409-33 2500 2500 5000 265-46409-25 265-46409-43 265-46409-34 3000 3000 6000 265-46409-26 265-46409-25 265-46409-35 3500 3500 7000 265-46409-27 265-46409-26 N/A 4000 4000 8000 265-46409-29 265-46409-27 265-46409-36 4500 4500 9000 265-46409-30 265-46409-28 265-46409-37 5000 5000 10000 265-46409-31 265-46409-29 265-46409-38 5500 5500 11000 265-46409-44 265-46409-30 265-46409-42 6000 6000 12000 265-46409-45 265-46409-31 265-46409-39 Tools required for conversion: 1. 1 ½" deep-well socket or wrench. 2. Phillips head screwdriver. 3. ¼" nut-driver or socket. 4. Thread lubricant.! WARNING High voltage potential exposure. To avoid personal injury, be sure water heater is disconnected from power source prior to performing the procedure. Page 2 of 8

Element(s) Removal: 1. Turn off electrical power to water heater, DISCONNECT FROM POWER SOURCE. 2. Drain water heater. Remove screw 3. Remove element access cover(s). Element access cover 4. Remove Insulation. Remove insulation 5. Remove thermostat(s) protector. Remove thermostat protector Page 3 of 8

6. Disconnect wire leads from element(s) terminal block. Element terminal block Disconnect wire leads from element terminal block 7. Remove element(s) from tank using 1½" deep well socket or wrench. Unscrew element(s) counter-clockwise to remove from tank. Unscrew element(s) counter-clockwise to remove from tank Element(s) Installation: 8. Check element terminal block for proper electrical rating. Note: Some elements have a dual rating, so be sure to check all surfaces on element terminal block. Check rating(s) on element Page 4 of 8

9. Apply new gasket(s) to new element(s) from conversion kit. Note: Make sure gasket is seated flat against element flange without rolls or gaps. Gasket 10. Thread new element(s) clockwise into tank. Tighten element(s) with a 1 ½" deep well socket or wrench. Do not over tighten. Over-tightening may damage gasket. Note: Clean any debris from element(s) fitting to tank. Lubricate element(s) threads as needed with thread lubricant. Element flange 11. Be sure tank is filled with water and check for leaks. 12. Reconnect wire leads to element(s) terminal block. 13. When converting from 208, 240, or 480 volt to 120 or 270 volt it is acceptable to tag the red wire with white electrical tape to identify wire. It is also acceptable to tag the white wire with red electrical tape when converting from 120 or 270 volt to 208, 240, or 480 volt. 14. Replace thermostat(s) protector and insulation. Thread element(s) clockwise into tank 15. Replace access cover(s). 16. Restore electrical power. Reconnect wires leads to element(s) terminal block 17. Place appropriate label (supplied with kit) so it covers electrical information on water heater rating plate. Note: Be certain not to cover model number, serial number and capacity information. Cover electrical information only with appropriate overlay Water heater rating plate Page 5 of 8

NOTES Page 6 of 8

NOTES Page 7 of 8

NOTES Page 8 of 8