Orion-LØV LØV-R with Sirius

Similar documents
Orion-Opus LØV-R with Sirius

Orion-PTV LØV-R with Sirius

Orion-LØV LØV-R with Sirius

LØV-R. Svalbard-H. Chilled beam for corner installation between wall and ceiling

CONDOR. Supply air ceiling QUICK FACTS

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Ceiling diffusers. Type DLQL

CHILLED BEAM CASSETTE IQ STAR LYRA

iq Star LYRA II chilled beam cassette

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Halton Rex 600 Basic R6B - Active chilled beam

Units for suspended ceilings

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Ceiling swirl diffusers

Ceiling swirl diffusers

HOTEL CHILLED BEAM IQ STAR SILENCIA

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Heat recovery unit RDKS

Halton Rex for Vario R6O - Variable air volume chilled beam

TURBO HOODS. Product Brochure

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

TTC. TTC Active supply air diffuser. Product description. Introduction SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Simplicity

iq Star LYRA II chilled beam cassette

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

System architecture. Air treatment Index

WOLF VENTILATION SYSTEM PRICE LIST

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

TopMaster Air Handling unit. Technical data

SECTION AIR DUCT ACCESSORIES

Bevent Rasch RABC-VAV. - Fire /03/2018

PARAGON. Compact comfort module. Key figures

Air distribution systems. Opticlean OC-Q...

QTS SELECTION TECHNICAL BOOKLET

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

Cooling Strip Model SPB

Ceiling air diffuser INDULTHERM INDULTHERM-e

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

Fan Coil Unit CULTRA

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Unit heater with accessories

EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE

Fan heater SWT Ceiling mounted fan heater with water heat

EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE

CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL FLOW PATTERN ONBOARD/REMOTE SENSING EXCELLENT THROW & FLOW HEATING AND COOLING CHANGEOVER

UV-TURBO HOODS. Product Brochure

Technology for life. Unit heater LH

Polaris-I-60. active chilled beam. the future of space conditioning

42AM. Air heaters PRODUCT SELECTION DATA

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

TopMaster Air Handling Unit

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

KOMFORT EC DB Suspended heat recovery air handling units

Fire dampers. For diverse applications

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

TTC. TTC Active supply air diffuser. Product description SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Introduction. Simplicity

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Units for suspended cei lings

Bevent Rasch BSKC6. - Fire /06/17

BSK-RPR Fire Damper. Additional operating instructions according to

Smoke extraction duct of sheet steel

FMC(Z) cartridge filter

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

ADAPT Parasol EX. Energy-saving, suspended comfort module QUICK FACTS

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

VAV DIFFUSERS PREVENT DUMPING VAV DIFFUSERS SAVE FAN ENERGY ENERGY SAVING - LOW PRESSURE LOSS REHEAT, OCCUPANCY, FLOW MEASUREMENT

Supply air unit VEKA Installation & Maintenance

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

KLIMA Active Chilled Beams

VEX100 series Air handling units with cross-flow heat exchanger

PARASOL EX. Suspended comfort modules QUICK FACTS

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Series VENTS VUT R WH ЕС

TECHNICAL SPECIFICATION

THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER

Bevent Rasch. FIDm. - Fire /11/2018

Extraction systems for the electronic industry. Soldering workstations Soldering smoke extraction systems

Heat Recovery Unit HERU. web-version

Recessed. Air Curtain. Fig 1. Recessed air curtain

Transcription:

GB0652 01.18 Orion-LØV LØV-R with Sirius VAV box for supply diffuser Unique damper function Extensive working range Belimo MP-Bus Modbus LONWORKS Belimo KNX TROX Auranor Norge AS PO Box 100 NO-2712 Brandbu Telephone: +47 61 31 35 00 Fax: +47 61 31 35 10 E-mail: firmapost@auranor.no www.trox.no

APPLICATION Orion-LØV with Sirius is a diffuser unit with VAV function, and is used as volume flow controller and diffuser in ventilation systems to enable air flow rates to be set as per requirements. Orion-LØV offers excellent induction, and is ideal for variable air flow rates. FUNCTION Orion-LØV with Sirius has a built-in VAV controller for adjustment of air flow rates according to requirements. The damper solution will choke the pressure at high flow rates and will maintain a low sound level. This may reduce the need for additional dampers and sound attenuators in a duct system. Orion-LØV with Sirius is delivered with Belimo MP-bus, LON, Modbus or Belimo KNX for direct BUS communication to SD systems. Deviation for working range 10-20% of V nom :±25% 20-40%: of V nom <±10% 40-100%: of V nom <±4% If T-pipes are used, a spacing of at least 5 x ØD is recommended in order to maintain the measurement accuracy. The diffusor front can be supplied with integrated motion sensor or motion/temperature sensor. Motion/temperature sensor is only to be used together with X-AIRCONTROL Product sheet for Motion and motion/temperature sensor can be found by following this link: Orion X-sense ORDER CODE, diffuser - Orion-LØV Sirius Orion-LØV-Sirius TA B 200 Modular ceiling system: TA=A-flange DC=Dampa Clip-In DG=Dg-flange DS=Ds-flange EK 24=E-flange-T24 EK 15=E-flange-T15 Sensor election: B=Motion sensor BT1=Motion and Temperature sensor Orion-LØV-Sirius-TA-B-200/0 Explanation: Orion-LØV-Sirius supply diffuser with A flange for T-profile ceiling system, motion sensor at diffuser front, spigot Ø200 ORDER CODE, Sirius 0 Dim: Ø200 Ø250 Ø315 Ø400 SL=Special finish DESIGN Orion-LØV with Sirius is a complete measuring and control unit where the air flow rates in ventilation systems can be set as required. At the measuring station, the differential pressure is measured by using measuring rods integrated in the unit. Sirius is equipped with LHV.D3 VAV controller from Belimo. Controller specifications are provided in the table below. Full technical documentation can be downloaded from www.belimo.eu. Orion-LØV features a removable front panel with LØV perforation, and is suitable for a range of ceiling systems. Sirius - 125-200 - 1 Dim: 125-200 160-250 200-315 250-400 Connection: 0 = MP-Bus 1 = MP-Bus with Winsta plug 2 = LON-Bus 3 = MOD-Bus 7 = Belimo KNX 8 = MOD-Bus for XAC 9 = MOD-Bus for XAC-ZM Actuator LHV-D3-MP/MOD/LON Operating voltage AC 24 V 50/60 Hz, DC 24 V Power drain 2,5W Dim. effect 4.5VA (max.8 A @5 ms) Sirius-125-200-1 Explanation: Sirius with Ø125 inlet and Ø200 outlet, with MP-Bus with Winsta plug. Table 1: Technical specifications, Belimo VAV controller MATERIALS AND SURFACE COATING Sirius comes in a galvanised steel design. The measurement unit is in aluminium, and hoses and nipples are in plastic. The damper is equipped with polyester material, and the connection collar is fitted with EPDM rubber gasket. 2

QUICK SELECTION, Orion-LØV with Sirius [open] m³/h Sirius dim. 25dB(A) 30dB(A) 35dB(A) 125 155 184 220 160 256 310 374 200 374 446 529 250 526 626 749 (75Pa) m³/h Sirius dim. 25dB(A) 30dB(A) 35dB(A) 125 144 184 220 160 234 295 374 200 367 443 529 250 342 569 734 DIMENSIONS AND WEIGHT, Orion-LØV with Sirius Dim. D DA B H L L1 Weight Weight Sirius Sirius with valve [kg] [kg] 125-200 124 202 325 175 645 386 8 12 160-250 159 252 360 210 645 402 9 13 200-315 199 317 400 240 645 435 10,5 14,5 250-400 249 402 450 290 645 392 12 16 Table 4 Table 2: Quick selection, Orion-LØV with Sirius Sirius (m³/h) ØD. Minimum Maximum 125 26 265 160 43 434 200 70 700 250 106 1060 Table 3: Adjustment range for VAV controller, air flow rate in m 3 /h. See calculation diagram for sound power level and pressure drop. Fig. 1: Dimensions, Orion-LØV with Sirius ORDER CODE, Orion-LØV with Sirius Orion-LØV-Sirius TA B 200 SK 0 SL = Special finish Modular ceiling system: TA=A-flange DC=Dampa Clip-In DG=Dg-flange DS=Ds-flange EK 24=E-flange-T24 EK 15=E-flange-T15 Sensor election: B=Motion sensor BT1=Motion and Temperature sensor Dim: Ø200,Ø250,Ø315,Ø400 SK - 125-200 - 1 SK=Sirius Inlet-outlet 125-200 160-250 200-315 250-400 Connection: 0 = MP-Bus 1 = MP-Bus with Winsta plug 2 = LON-Bus 3 = MOD-Bus 7 = Belimo KNX 8 = MOD-Bus for XAC 9 = MOD-Bus for XAC-ZM Orion-LØV-Sirius-TA-B-200-SK-125-200-1/0 Explanation: Orion-LØV-Sirius supply diffuser with A flange for T-profile, motion-sensor in diffuser front, spigot Ø200, Sirius box Ø125 inlet and Ø200 outlet, with MP-Bus with Winsta plug. 3

ACOUSTIC DATA The diagrams provide a summary of the A-weighted sound power level from diffuser, L WA. Correction factors in table 5, page 5, are used to calculate emitted sound power level at the respective frequencies, L W = L WA + KO. A room with absorption equivalent to 10m² Sabine will have a sound pressure level which is 4 db below the sound power level emitted. CALCULATION DIAGRAM Sirius 125 with Orion-LØV supply diffuser, desired volume flow 50 l/s. From diagram 1, we find that L WA = 26 db(a) with open damper and 45 Pa total pressure drop. The aim is to find the following data: a) Emitted sound power level at 250 Hz b) A-weighted total sound pressure level from diffuser in an office with 4dB room attenuation. c) A-weighted sound pressure level in an office at 75 Pa total pressure loss, i.e. 30 Pa choking with the unit s damper. a) The correction factor for 250 Hz -2 db. Emitted sound power at 250 Hz is then: L W = L WA + KO = 29 + (-2) = 27 db b) With room attenuation equivalent to 4 db, A-weighted sound pressure level is: 29-4 = 25 db(a) c) At the operating point of 50 l/s and 75 Pa total pressure loss, the diagram indicates 29dB(A). With 4dB room attenuation the sound pressure level in the room will be: 29-4 = 25 db(a) Diagram 1, Orion-LØV w/sirius Ø125 Diagram 2, Orion-LØV w/sirius Ø160 Diagram 3, Orion-LØV w/sirius Ø200 Diagram 4, Orion-LØV w/sirius Ø250 4

Right pressure drop line (open) KO [db] Left pressure drop line (heavily choked) Sirius dim. 63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k 125 4-1 -2-1 -6-11 -15-11 2-3 -4-9 -6-6 -8-9 160 2 1 0-1 -8-13 -13-9 1-1 -3-6 -4-11 -11-9 200 2 1-2 -1-6 -12-14 -10 1 0-3 -5-5 -9-9 -9 250 3 2-1 -1-7 -13-13 -10 2 2-1 -3-6 -11-10 -9 Table 5: Correction factor, Orion-LØV with Sirius THROW LENGTH FLOW PATTERN Diagram 5, Orion-LØV with Sirius throw length Fig 2: Flow pattern, Orion LØV Orion-LØV with Sirius Attenuation [db] Dim. 63 125 250 500 1k 2k 4k 8k 125 14 11 12 12 18 11 14 15 160 12 9 12 11 16 10 14 15 200 10 8 11 12 15 12 12 14 250 8 7 11 12 13 13 13 14 Pt(Pa) 450 400 350 300 250 125 160 200 250 Table 6: Static sound attenuation incl. end reflection, Orion-LØV with Sirius 200 150 100 50 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 q (l/s) Fig. 3: Sirius, leakage at closed damper 5

INSTALLATION The Orion-LØV diffuser can be installed in a range of modular ceiling systems as well as in fixed ceilings. Sirius is attached to the rear of the support bracket by means of threaded rod or strap (fig. 5). In order to maintain the system s measurement accuracy, it is important to install units with spacing as shown in fig. 6. A A-kant flange Dampa Clip-In DG Dg-kant flange COMMISSIONING Orion LØV with Sirius uses Belimo PC-TOOL or ZTH-GEN in order to make the requisite adjustments. MAINTENANCE No specific maintenance requirements. ENVIRONMENT Enquiries regarding product declaration can be directed to our sales team, or information can be found at our website: www.trox.no DS Ds-kant flange E E-kant flange T24/T15 Fixed Fast himling ceiling Fig.4: Installation Fig. 5: Installation Orion-LØV with Sirius is developed and manufactured by: Fig. 6: Installation The company reserves the right to make amendments without prior notice. www.tintkom.no Head Office: TROX Auranor Norge AS, PO Box 100, NO-2712 Brandbu Telephone: +47 61 31 35 00 Fax: +47 61 31 35 10 www.trox.no 6 6 6