Plastic plate heat exchanger

Similar documents
DIVISION 15 MECHANICAL

Direct Fired Heater Model AD Specification

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

SECTION AIR HANDLING UNIT

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

SECTION AIR COILS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

Softcool evaporative cooling

STERI-VAC CENTRAL SUCTION SYSTEM

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Submittal Data Performance Data Electrical Data

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

AIR HANDLER SPECIFICATION

Air Handling Units. T F E.

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

DOCUMENT TABLE OF CONTENTS

Ventilation for New Low-Rise Residential Buildings July 20, 2015

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

BLAST-IT-ALL BUMPER BLASTER

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

CONTENTS DE-HUMIDIFICATION IN INDOOR SWIMMING POOLS 2 DESIGN PROPERTIES OF THE INDOOR POOL DE-HUMIDIFYING UNIT 4 FRAME STRUCTURE 6 PANEL STRUCTURE 6

TYPICAL CPA SPECIFICATIONS

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

Centeral Station Air Handling Unit

SECTION (15820) - AIR DUCT ACCESSORIES

INSTALLATION AND USER MANUAL

Electron Microscopy Sciences

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design.

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

1.1 This section applies to air handling units for HVAC Systems.

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Instructions for Operation and Maintenance of Containers

PRODUCT CATALOGUE THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

Displacement Ventilation

Operator s Manual. IP-100 Immersion Probe Cooler

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

COMcheck Software Version Mechanical Compliance Certificate

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

Technical Catalog laboratory furniture system

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

DES CHAMPS PRODUCTS 85% 4,400 CFM

Enviro International Corporation. WET SCRUBBER

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

CxA to Answer this Section

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

RDT Refrigeration Book

13 HYGENIC AIR HANDLING UNITS

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Operating instructions. Web Cleaner 1 / 2. Air Line

Chilled Water DOAS Fan Powered Terminal Units

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

INSTALLATION, OPERATION AND SERVICE MANUAL MIGHTY ION MODEL MI SERIES

INSTALLATION OPERATION MAINTENANCE

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Cleaning systems Overview

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Our energy efficient experts and engineers have made ground breaking innovations in this field.

Appendix A.4.1. Safe Fume Hood User Guide

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

FIGURE 1. Model RD107

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

User s Information Manual

Air treatment solutions. Aftercoolers & condensate treatment

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Technical Catalog laboratory furniture system

YOUR GUIDE. Product Maintenance Guide. How to look after your product. PVC-U Windows, Doors & Conservatories

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Code verification sign-off

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

APW PSI PRESSURE WASHER

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

In the event of this condition, consult the Authorities Having Jurisdiction for guidance and approval.

Double Skin Casing Air Handling Units

Portable Air Conditioner Instruction Manual

SHELL AND TUBE HEAT EXCHANGERS FOR INDUSTRIAL ONCE-THROUGH COOLING SYSTEMS AND THE OCCURRENCE OF LEAKAGE

A DIVISION OF HOSE & TUBING CATALOG 2017

Commercial Flat Concealed Sprinkler, Pendent, Quick & Standard Response, Standard Coverage, Model: CN-QR, K-Factor: 5.

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Use Metal Bellows To Replace Springs Benefits of Precision Metal Bellows as Spring Replacements in Mechanical and Electrical Applications

AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking...

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

Used Fluid Handling Portable Used Oil Gravity Drains

GASEOUS HYDROGEN SYSTEMS

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Air flow m3/h

Transcription:

2014US - 7.3.1 PWT-plastic Plastic plate heat exchanger Applications POLYBLOC is the right choice for highly corrosive pollutants. Plate heat exchangers in exhaust systems for brine baths, electroplating shops and laboratories are generally made from PP. For particularly corrosive media (such as chromic acid) the heat exchanger can also be made from PVC. The design has been specifically matched to the use of PP and PVC. Particular attention was paid to controlling the high expansion coefficient typical of plastics in connection with the asymmetrical temperature profiles that occur inside plate heat exchangers. Failure to observe this problem leads to substantial leakage between air streams as individual plates buckle. Although this guarantees trouble-free operation of the heat exchanger over many years, the following points should nevertheless be considered: Temperature resistance Suitable steps must be taken to ensure POLYBLOC PP plate heat exchangers are not subjected to temperatures above 200 F (PVC 140 F), not even temporarily. This also applies to the cleaning process. Corrosion characteristics POLYBLOC PP plate heat exchangers must not be exposed to any pollutants other than those advised at the time of order. The suitability of the plastic must be checked for each individual application.

2014US - 7.3.2 PWT-plastic Installation and operating information Installation information 1. When installing the heat exchanger inside a ventilation unit, the HE plates must always be vertical. This permits good drainage of the condensate and prevents an excessively increased pressure drop due to condensate formation on the air side. It also prevents the weight of the condensate that forms in the grooves and on the protrusions from compressing the exchanger. Arranging the plates horizontally is not permitted. 2. When handling the exchanger during installation, ensure that the folded edge is not subjected to outward loads (away from the heat exchanger block). Otherwise there is a risk that the gasket will tear off. 3. The internal leakage rates between the air streams are very low. When installing the heat exchanger in a ventilation unit enclosure, pay particular attention to air tightness. This means that the ventilation unit bulkheads on all 4 exchanger edges must be sealed using suitable materials and methods. Please note: The heat exchanger application limits (temperature, pollutants, differential pressures) should be observed. The seal between the heat exchanger and the wall of the ventilation unit must be strong enough to withstand any possible deflection due to internal excess pressure on this wall. No tensile strain must be exerted on the lateral end of the heat exchanger. This means that the wall of the ventilation unit must not be secured to parts of the plastic frame. 4. In the case of poisonous substances in the exhaust air, the supply air fan inside the heat exchanger must generate a higher pressure (at least 0.40 inwc) than that on the exhaust air side. This prevents contaminated air reaching the supply air stream in the case of a leak. When stopping the fans, the exhaust air fan must be stopped first. The supply air fan is then stopped after a short delay. When starting the system, the supply air fan must start first, followed by the exhaust air fan. Safe operation must be ensured by means of suitable control in the event of a fan failure. 5. Arrange the fans so that no pressure differential greater than 8.0 inwc can be created inside the plastic heat exchanger. 6. Never connect a fan directly to the intake side of the heat exchanger. The turbulence can cause vibrations, which in turn can result in damage from material fatigue. Furthermore, this has a detrimental effect on heat exchanger performance. Fit a short diffuser (stable perforated panel with four spacers) at the pressurised connector. 7. The air streams must not contain any substances that will corrode polypropylene and polyurethane (sealants), even if watery condensate occurs simultaneously.

2014US - 7.3.3 PWT-plastic Operating information 1. Preferably clean the heat exchanger with hot water (up to 180 F, max. pressure 40 psi), using a mild detergent and a manually guided hose. Never use high pressure cleaners. Also, never use mechanical cleaning apparatus (such as screwdrivers or brushes) for cleaning the heat exchanger. 2. Inside the customer s enclosure on site, provide a full length drain pan underneath the exchanger (return air / exhaust air and outdoor air / supply air section) made from suitable material. This must be equipped with sufficiently large drain outlets (also for cleaning purposes). Provide these with appropriate traps. If required, also fit drip separators. 3. Provide an outdoor air bypass in order to protect the heat exchanger from icing up. Size the reheater coil sufficiently large, to compensate the bypass operation with cold outdoor air. The bypass damper can be made from aluminum if it is located in the outdoor air. If certain criteria demand a bypass damper in the return air stream, such dampers must be made from stainless steel or plastic.

2014US - 7.3.4 PWT-plastic Engineering information for POLYBLOC plastic plate heat exchangers Installation type W (no bypass or damper) Installation type WBY for ventilation units (with bypass and damper) Polypropylene plate heat exchanger, suitable for air handling systems with highly corrosive air streams. Made from deep drawn polypropylene plates, structurally optimized for low pressure drop and high transfer rates. Corona-treated surface for improved transfer rate in the case of condensation. Original material thickness: 0.7 mm. A flexible PU sealant is used to seal between individual plates. Plates are connected by means of interlocking joints and secured using ultrasound welding. The gasket is totally enclosed inside a groove. Permissible differential pressure inside the exchanger: 8.0 inwc. Block casing made from 20 mm polypropylene plates, with plastic/ stainless steel composite corner profiles. These are reinforced with fully encapsulated stainless steel profiles. Block casing made from 20 mm polypropylene plates, with plastic composite corner profiles. These are reinforced with fully encapsulated stainless steel profiles. With integral bypass enclosure and aluminum bypass damper. Bypass damper also available on request in stainless steel or plastic. Type N Plastic heat exchanger available in an N enclosure with bypass and bypass damper. Also available with an automatic cleaning facility system.

2014US - 7.3.5 PWT-plastic Plastic heat exchanger enclosure versions Type D Plastic heat exchanger in enclosure, for flow rates from 600 to 24,000 CFM.