Transportation. Distribution

Similar documents
Independent, accredited testing station Member laboratory of STL and LOVAG

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

Survey of electrical equipment installed in hazardous areas on tankers

ELSTA MOSDORFER- Energy Distribution with Competence

FALCON SERIES 12 METAL CLAD

CR A-F-A-E-HQQE 3x400/ HZ

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

IEC/TC IEC/TC44 IEC/TC44. Amd.1DC:201. Ed.3CD:2011. Ed.2.1:2008. Amd.1CDV ED.1: 一連番号 Ed.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

TECHNICAL SPECIFICATION AUTOMATIC SINGLE POLE AND THREE POLE CIRCUIT BREAKERS FOR LV SUPPLIES

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

FALCON SERIES 12 METAL CLAD

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Section 8: Switchgear Connections (Straight & Elbows)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

IECEx Certificate of Conformity

Operating Manual Distribution box

This document is a preview generated by EVS

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

Flange immersion heaters

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

Withdrawable module with vacuum circuit-breaker 3AE and installation accessories kv, ka kv, 40 ka 24 kv, ka

Eldon Product Overview

Frost Protection Thermostat

Lloyd s Register Type Approval System Test Specification Number 3

Screw plug immersion heaters

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

CR20-07 A-F-A-E-HQQE 3x400/ HZ

GENERAL SPECIFICATION ELECTRICAL

Here Comes the Sun!!!

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS)

Energy Division. DAH series (IEEE) Distribution metal oxide surge arrester

Level Electrode NRG NRG Original Installation Instructions English

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

Rules for Classification and Construction Additional Rules and Guidelines

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Instruction Manual April sitrans AS 100

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA1 Series, (IEC)

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

Section 5: Medium Voltage Joints - up to 42kV

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

PolyGarde Metal-Oxide Surge Arresters

HMN-D2 Insert Series

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

Chemical Pumps Vertical Chemical Pump Type TNP

TENDER NO. PGVCL/PROC/SMC BOX FOR CT OPERATED METER & Junction Box/867

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Standards - Withdrawn The dates in brackets following the document number are the year of publication and the withdrawal date.

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Hazardous Area Zirconia Oxygen Systems

let us discover the seven p3ductal gears

CP+ Gas & Oil Cabinet Heater Range

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

flue pipes flue pipes

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

PowerWave 2 Busway System

Halton CPT Passive Chilled Beam

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

SECTION PLUMBING EQUIPMENT

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Twin radial blower DRG 730

SPACE DETECTOR SP Presentation

Tubular Industrial Process

IEC THE PROMISE THE PROOF HEATEX INDIRECT EVAPORATIVE COOLING AIR-TO-AIR HEAT EXCHANGERS

Optimal work climate with open doors. Industrial air curtains Model IndAC

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Which RO/DI Water Heater is Right For Your Application? By: Caitlin Carrier

XEON. High impact resistant body and PC cover. Double layer coating. through wiring. Build-in microwave sensor.

Certificate of Compliance

Transcription:

Distribution Transportation

Busbar Shielded Systems type: Cast Resin Low Voltage The shielded busbar system, ISOBUSBAR, type IS isolated in polyester or epoxy resin, have been specifically developed for transportation and distribution of electric energy in a range of intensities from 160 to 6300 A and a voltage up to 1000 V. The design was made to answer almost all possibilities in installation and connections. Due to his special characteristics and his solid construction, our product is the ideal system for use in all surroundings. Even in corrosives and aggressive environment. Isobusbar IS series Composition: Conductors: - The conductors are profiles and/or copper bars with a purity greater that 99,9%. - ETP 99,9 DIN 1787-46433-40500. Copper Tin plated Connection holes: - Adapted for intensity and temperaturerise. - Limited according the standards EN60439-1 & -2. 1/21

Double insulation: 1. First : taped around the entire length. 2. Second: the enclosure of the ISOBUSBAR cast resin products consists of a polymerised synthetic resin (polyester or epoxy), reinforced with mineral charges. Isobusbar IS series The conductors are completely isolated prior to be installed in the cast resin isolation (double). These insulated conductors are immersed in our special polyester or epoxy resin mixture. Our design offers very good thermal characteristics and is in full compliance with the applicable standards. Moreover it ensures excellent mechanical resistance and short-circuits withstanding. The special enclosure also assures complete protection of the conductors in a corrosive and aggressive ambience. The significant advantages of these busbars compared to traditional systems are: - Integral isolation of the complete line. - Overload admissible. Up to 25% during two hours. - Easy and fast installation without the need of special tools. - Maintenance free. - In accordance with IEC 60439/1-2 standards and equivalents. - Degree of protection IP-66 or IP68 for the complete line, as per IEC-60529 standard. - Maximal resistance against salty, corrosive and/or aggressive atmosphere and suitable for outdoor use. Pollution Degree 4, IEC-60664-1. - Large contact surfaces between busbars elements and connected electrical equipments, assuring optimal current density. - Installations without chimney effects, meaning no flame propagation. - Fire resistance in accordance with IEC 60439/1-2 standards. - Function integrity of > 40 min. in plain fire. 2/21

Structure: 3 phases 3 phases + N (50%) 3 phases + N (100%) or (2N 50%). Possible configurations : 3P, 3P+N, 3P+PE, 3P+1/2N, 3P+1/2N+PE, 3P+N+PE, 3P+PEN, 3P+2N. The ISOBUSBAR IS-series type can be used as a riser busbar to distribute the electrical energy. The tap-off boxes can be fixed to the busbar or plugged in into the system. The plug-in boxes have an IP-54 degree of protection and the fixed boxes are suitable for IP-66 degree of protection. Tests specifications: - Standards: IEC60439-1 & 2 (+ IEC 60059 : Standard current ratings). - Type test: performed in accredited laboratories according to ISO17025. - Routine tests: dielectric strength and insulation level, performed on all manufactured components. 3/21

Temperature-rise limits (conductors and enclosure): Test arrangement according with the standard IEC60439: Ambient air temperature : max 40 C, Temperature-rise limits Conductor (joints): - 90K (class B) - 115K (class F) Thermocouples (joints) Enclosure (resin insulation): - 55K The test shall be made for a sufficient time for the temperature rise to reach a constant value (but not exceeding 8 h). In practice, this condition is reached when the variation does not exceed 1 K/h. (To shorten the test, if the devices allow it, the current may be increased during the first part of the test, it being reduced to the specified rated current afterwards.) Also to consider: the reduction factors related to temperature and effects of the proximity to any electrical conductors. 4/21

Isobusbar IS series Fire resistance according with the standards: IEC60439-1 & 2: - Resistance to abnormal heat and fire. - Verification of resistance to flame-propagation. - Verification of fire resistance. Test result after 4 hours of plain fire no flame propagation: Side A Side B «fire side», insulation and copper are melting, without the fire passing to the other side of the wall All tests are conducted in accredited laboratories according to ISO17025 standard. 5/21

Tests performed: Verification of temperature rise limits Limit: Class B (95K) Class F (115K) A. ref mm² Rapport Limit (K) Temperature Rise (K) Temperature Rise (K) enclosure enclosure conductor (K) conductor in the joint ka/1s Shortcircuit 800 ISC08/1 325 B124-03-BP-11-02e 55 16,3 36,8 37,4 40 1000 ISC10/1 400 B124-03-BP-11-03e 55 21,0 53,6 54,3 45 1250 ISC12/1 500 B124-03-BP-11-04e 55 28,1 56,7 60,7 50 1750 ISC17/1 750 B124-03-BP-11-05e 55 30,6 73,4 78,8 56 2000 ISC20/1 1000 B124-03-BP-11-06e 55 25,8 57,1 59,0 70 2500 ISC25/1 1400 B124-03-BP-11-07e 55 34,4 65,5 69,3 80 3150 ISC31/1 1700 B124-03-BP-11-08e 55 31,6 74,8 80,3 85 4000 ISC40/1 2100 B124-04-BP-EE-01E 55 Max 29,3 Max 64,7 Other test: - Verification of the dielectric properties (5250V- 5s). - Degree of protection (IP66-IP68). - Verification of clearances and creepage distances (pollution degree 4 = the pollution generates persistent conductivity caused, for instance, by conductive dust or by rain or snow). - Verification of the structural strength with normal mechanical loads. - Determination of resistance, reactance and impedances values. Laboratory: Labein (http://www.labein.es/) 6/21

Isobusbar IS series Modelpieces: - straight line: - straight line with tap-off box - elbow 90 and Z-piece, horizontal and vertical 7/21

T-piece: Isobusbar IS series Special flanged ends (terminations to transformers, panels, switchgears...) and joints: 8/21

Joint 1/ bolting bars Joint : 2/ Insulation with resin to obtain an IP-66/IP-68 degree of protection Terminations: flexible laminated coupling pieces and protection box (IP42/55) possible to be painted in the same RAL colour as the installation. Note: In this brochure we show the standard elements. But it s possible to manufacture any custommade pieces specially designed for your project. Our technical department will study each request for special pieces and check the possibilities of manufacturing. All dimensions, lengths, weight... can be requested according your project. Moreover, we can supply apart from the busbars, all necessary accessories such as flexibles, mounting brackets, expansion units, fire barriers, coupler boxes,. and others. Technical assistance during the installation works on site is available under request. 9/21

Isobusbar IS series Example of terminations and joints: As well as the busbars, Nexans supplies all MV-accessories for transformer and/or panel connections. Please visit our website: www.euromold.be or www.nexans.be for all your requests. 10/21

Examples of realisations: 11/21

12/21

Busbar Shielded Systems type: Cast Resin Medium Voltage The shielded busbar system, ISOBUSBAR, type IMT (non segregated busbar) and IMTS (segregated busbar) isolated in polyester or epoxy resin have been specifically studied for the transport and distribution of electric energy in a range of intensity from 1000 to 6300 A and a voltage between 3 and 36 kv. The design was made to answer almost all possibilities of installation and connection. The special characteristics and the solid construction make our product the ideal system for use in corrosives and aggressive surroundings. Isobusbar IMT series Composition: Conductors: - The conductors are profiles and/or copper bars with a purity greater that 99,9%. - ETP 99,9 DIN 1787-46433-40500. Connection holes: - Adapted for intensity and temperature-rise. - Based on the DIN 46206 and 43673T1, connecting copper bars electrically/mechanically. The DIN standards indicate the quantity of bolts according to the intensity. 13/21

Double insulation: 1. First : medium voltage heat-shrink tube. 2. Second: the enclosure of the ISOBUSBAR cast resin products consists of a polymerised synthetic resin (polyester or epoxy), reinforced with mineral charges. (Example of 1 phase) Isobusbar IMT series After the first isolation, the conductors are inserted in a special isolating material. It consists of special polymerised resin (polyester or epoxy) reinforced with mineral charges of determined granulometry and inflammable materials. Our design offers very good thermal characteristics and is in full compliance with the applicable standards. Moreover it ensures excellent mechanical resistance and short-circuits withstanding and a IP-66 degree of protection (in accordance with IEC-60529 standard). Threaded rods for fixing the metal enclosure Fonctions of the resin block: - short-circuits withstanding (dynamic effects) - limit the spread of fire - fixing the phases together 14/21

Standards: IEC60271-200 and IEC62271-1 Test specifications: - Type test: performed in accredited laboratories according to ISO17025. - Routine tests: dielectric strength and insulation level, performed on all components manufactured. Metal enclosures: - Type test: Around this cast resin enclosure, the busbar has a housing manufactured made off anodized aluminium to protect the system from outside mechanical aggressions and reducing the electro-magnetic field. It is available in any RAL colour, through polyester painting. Any other finished form is available under request. Acting as PE conductor and by means of its earth connection it is a personal protection against electrical accident. Isobusbar IMT series non segregated busbar ventilation openings mounting profiles Isobusbar IMTS series segregated busbar 15/21

Temperature-rise limits according the standard IEC 62271-1 (for conductors & enclosure): The test material was setup according to this standard. Ambient temperature: max. 40 C. Metal enclosure Temperature-rise limit: 40K Copper conductors (joint and end) Temperature-rise limit: 65K Also to consider: the reduction factors related to temperature and effects of the proximity to any electrical conductors. 16/21

Isobusbar IMT & IMTS series Fire resistance according with the standards: IEC60439-1 & 2: - Resistance to abnormal heat and fire. - Verification of resistance to flame-propagation. - Verification of fire resistance. Test result after 4 hours of plain fire no flame propagation: Side A Side B «fire side», insulation and copper are melting, without the fire passing to the other side of the wall All tests are conducted in accredited laboratories according to ISO17025 standard. Isobusbar IMT series Modelpieces: - straight line: degree of protection: IP66 17/21

- elbow 90, T- and Z-pieces, horizontal and vertical All dimensions and construction details to be defined for your project. 18/21

Isobusbar IMT series Special flanged ends (terminations to transformers, panels, switchgears...) and joints: Flexible coupling Reconstruction of the metal enclosure Note: In this brochure we show the standard elements. But it s possible to manufacture any custommade pieces specially designed for your project. Our technical department will study each request for special pieces and check the possibilities of manufacturing. All dimensions, lengths, weight... can be requested according your project. Moreover, we can supply apart from the busbars, all necessary accessories such as flexibles, mounting brackets, expansion units, fire barriers, coupler boxes,. and others. Technical assistance during the installation works on site is available under request. 19/21

Examples of realisations: 20/21

21/21

Additional catalogue information on power cable accessories is available by contacting us at the address below. Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan 12, B-9320 Erembodegem Tel.: +32 (0)53 85 02 11 Fax: +32 (0)53 83 10 13 www.euromold.be busbar.euromold@nexans.com 07/2012