Installation Instructions Azatrax HexDetex Model Train Detector with Grade Crossing Trigger MRD6X

Similar documents
Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

Azatrax Quad Infrared Proximity Detector Shield for ArduinoTM Uno, Mega and compatibles

easydetect and easydetect deluxe model train detector kits Quickar Electronics, Inc.

easydetect and easydetect deluxe model train detector kits Quickar Electronics, Inc.

An Ambient-Light-Ignoring Infrared Active Motion Detector

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

TrainBoss Defect Detector Displaying Detector Model No. TB-21D

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Model 3300 Technical Support and Installation Manual

LUX Hardwired - Installation Notes

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

HOA0880-T51. Representative photograph, actual product appearance may vary.

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Always make sure to check the heating film before, during, and after installation of the floor covering.

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Detector switch - Dual Tech

Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09

Automatic Night Lamp Circuit Diagram Using Ldr And Triac

Public Safety DAS Annunciator Panel

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

Polarized Retroflective Photoelectric Switches

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

INSTALLATION INSTRUCTIONS

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

Victoreen Primalert 35 Area Radiation Monitor

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

Installation Instructions

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Downrod. Canopy.

Run Your Trains, Not Your Track!

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

STEP BY STEP INSTALLATION INSTRUCTIONS. Vertical Honeycomb Shades

D-Tect 2 GJD300 Quad PIR Movement Detector

AUTOMATIC ROOM LIGHT AND FAN CONTROLLER WITH BI- DIRECTIONAL VISITOR COUNTER

LIGHTING CONTROL DEVICES

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Installation and Operation Guide for the UPS-64C Power Supply with CometFlash

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

INDICATOR LAMPS & LED REPLACEMENT LAMPS

NATIONAL CONTROL DEVICES MirC Wireless Quick Start Guide

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

What to Expect with Your Installation. Tools Needed. 30 inches PA G E. To register your fan, please visit: 11 PA G E

RMS/RPX Reader. User Manual

End To End Optical Beam Smoke Detector. Additional Information

EG-400 Fire Detection Monitor

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Installation and Operation Manual AEC9005 Series Low Voltage Warning and Auxiliary Battery Management Modules

BDL168. All Scales. LocoNet Occupancy Detector For 16 Detection Sections and up to 8 Transponder Zones

REMOTE CONTROL CAR ALARM SYSTEM

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents. Ceiling Bracket Installation

SECTION LIGHTING CONTROL DEVICES

4300 WINDFERN RD SUITE 100 HOUSTON TX VOICE (713) FAX (713) WEB: IMPORTANT!!!

Devices for Special Applications

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

CONTENTS BEFORE YOU BEGIN

Table of Contents. 1 M /10/14 Casablanca Fan Company. What to Expect with Tools Needed.

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

UP 258E11 OPTISENS OFFICE

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

UNDERWATER CAMERA HOUSING LEAK DETECTOR

LS800S Intruder Alarm System. Engineering Manual

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

A. This Section includes the following lighting control devices:

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

Owner s Guide and Installation Manual

HOA Series IR Opaque Optoschmitt Sensor, Transistor Output, Two Mounting Tabs, Plastic Package

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Service: to SLK Laboratory Hot Plates glass made of ideas

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

IR FLAME DETECTOR RIV-601/F

Sensing the World. When you have finished this lecture you should be able to:

FerronTM. Instruction Manual A Kichler Decor ceiling fan

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

OPERATION GARAGE Butler

XBee Based Industrial And Home Security System

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

MEGAbitty ProxDot Object Sensor Board (preliminary documentation) 5/1/2004

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

DS160/161 Request To Exit PIR sensors Installation Instructions

BB TM 508/509 ANTI TWO-BLOCK ALARM SYSTEM HYDRAULIC CRANE INSTALLATION. Greer Company Crane Systems. Greer Company

User Manual 120/240/300 Outdoor Motion Detector

ECONX FIT OFF INSTRUCTIONS

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

DUAL OPTIC. Installation manual

Product and Applications Description

Owner s Guide and Installation Manual

Transcription:

Installation Instructions Azatrax HexDetex Model Train Detector with Grade Crossing Trigger MRD6X What it is: The MRD6X is a six-channel model train detector. It can detect model trains at up to six different locations on the layout and activate up to six LEDs or six 5-volt, low current electronic circuits. If the sensors are placed on a track with a grade crossing, the MRD6X can turn a grade crossing circuit on and off with realistic timing. Kit contents: Circuit board Infrared light-emitting diodes (IR LEDs) with orange & white (2 ft length) or red & white (6 ft length) wire leads IR receivers with green & white (2 ft length) or blue & yellow (6 ft length) wire leads Plastic mounting tubes. The tubes are for protection of the sensor leads and to provide mounting support. They are not essential for detector operation and may be shortened or removed entirely to best fit your situation. Just use caution to avoid damaging the leads. Mounting screws How it works: Trains are detected by infrared (IR) light, invisible to the human eye. There are two sensing elements at each track location - an IR LED light source paired with an IR receiver. Yellow LEDs on the MRD6X show the status of the detectors -- 'on' if the circuit is detecting an object, 'off' if no object is being detected. A red LED turns on when the MRD6X determines that a grade crossing signal should be active. Installation There are four installation steps: Sensor installation, Power connection, Sensor adjustment, and Output connection. First, install the sensors: Each sensor pair may be installed in one of two different ways - 'Across the Track' or 'Reflective.' Choose locations according to how you will use the detectors. To locate sensors for triggering a grade crossing signal, see page 4. Across the Track sensing: The IR LED is positioned horizontally on one side of the track(s), and the IR receiver is placed on the opposite side. A train is detected when it blocks the light path between the LED and its receiver. The distance between the LED and receiver can be up to 18 in. (46cm), or more with careful alignment. Placing the sensors at an angle across the track(s) creates a longer detection zone and avoids possible detector flickering caused by the gaps between cars. Tip #1 - If mounting the sensors vertically as shown here, slide the plastic tubes away from the sensor then carefully bend the leads to a right angle. The leads are somewhat brittle, bending them more than two or three times may cause a break. Tip #2 - Locate the IR receiver so it faces away from bright lights or sunny windows. Use scenery or structures to conceal the sensors and shade them from room lighting. Tip #3 - The detection zone of each detector can be expanded by adding a second IR LED / receiver pair. Additional sensor pairs may be purchased from Azatrax, see the website www.azatrax.com for details. Reflective sensing: Trains are detected when light from the IR LED is reflected off a train and sensed by the IR receiver. Typically the sensors are mounted in two #12 (3/16 inch or 4.8mm) holes drilled in the roadbed as shown here. Vertical installation works for S, O and larger scales as long as there is no structure above the track such as a bridge. Angling the IR LED and its receiver toward each other is best for N and HO scale where the trains are close to the rail head, and in places where an object above the track might otherwise cause false detections. Angle the IR LED and receiver so their centerlines intersect at the height of the bottom of your rolling stock. Tip #4 - You can ballast your track after sensors are installed. Cover each sensor with a bit of transparent tape. Apply ballast. When the glue has dried use a dental pick or similar tool to remove ballast from the sensors. An opening of just 1 or 2 mm is required. 2015 Azatrax.com MRD6X HexDetex installation instructions pg. 1 of 5

Connecting wires to the terminal blocks: The MRD6X has 'spring cage' terminal blocks. Connections are made as follows: Strip 3/8 inch (1 cm) of insulation off the end of the wire. You can measure with the strip gauge printed near the edge of the circuit board. Use a small screwdriver to push down (push, do not turn) the terminal's button. Push firmly. While the button is pushed in, hold the wire at a 45 degree angle to the terminal block and push it in. About 3/8 inch of wire should go into the terminal block. Release the button. Tug on the wire to make sure it is secure. Connect sensor pair 1: Connect the orange (or red) wire from the IR LED to terminal 1K. Connect the green (or blue) wire from the IR receiver to terminal 1F. How you connect the two white (or yellow) wires to the MRD6X will determine whether Detector 1 will operate in 'Across the Track' or 'Reflective' mode. See the diagrams below. If using your own IR LEDs and receivers: The 'orange' wire is the LED cathode (-), the white wire is the anode (+). The green wire is the phototransistor (receiver) emitter (-), the yellow wire is the collector (+). Add connections for sensor pair 2: Connect the orange (or red) wire from the IR LED to terminal 2K. Connect the green (or blue) wire from the IR receiver to terminal 2F. As with sensor pair 1, how you connect the two white (or yellow) wires will determine whether Detector 2 will operate in 'Across the Track' or 'Reflective' mode. Detector 2 can operate in the same mode as Detector 1, or in a different mode. Note that when both sensor pairs are wired to the MRD6X, there will be two white (or yellow) wires in 'X' and two white (or yellow) wires in 'R.' Twist the ends of the wires together for a more reliable connection. Additional wire may be spliced to the sensor leads if needed. Use similar twisted pair wire for total length up to 25 ft (7.5m). Pairing is important! The IR LED that is connected to 1K must be paired on the layout with the IR receiver that is connected to 1F. And the IR LED that is connected to 2K must be paired on the layout with the IR receiver that is connected to 2F. Test and adjust sensor pairs 1 & 2 as follows before connecting the rest of the sensors: Connect power to the MRD6X: Connect an accessory power supply of 8 to 15 volts AC or DC to terminals P1 & P2. The red LED will briefly flash to show that power is on and the circuit is working. Adjust the sensors: With no trains in any of the detection zones, all of the yellow LEDs on the MRD6X module should be off. If any yellow LED is on, correct the false sensing condition. To fix false sensing for Across-the-Track mode: 2. Make sure the IR LED and its receiver are pointed at each other, and nothing is between them. 3. Shade the IR receiver from bright lights, and point it away from windows or other strong light sources. 2015 Azatrax.com MRD6X HexDetex installation instructions pg. 2 of 5

4. Change the nearby room light from incandescent to a fluorescent or LED bulb if possible. To fix false sensing for Reflective mode: 2. Pull the IR LED and its receiver a bit deeper into the roadbed. 3. Infrared light may be 'leaking' through the roadbed material from the IR LED to the receiver. Push a metal shim, such as the tip of a hobby knife blade, vertically into the roadbed between the IR LED and receiver. 4. Is there an object above the sensor, such as a bridge, or an upper layout level? Mount the IR LED and its receiver at a shallower angle, or paint the object flat black. Or use across-the-track sensing. Are all detectors now off? Now test for train detection. Place a locomotive or car in the detection zone of Detector 1. Yellow LED#1 should light. If yellow LED#2 also lights, re-adjust sensor pair 2 for false detection (see above). If LED#1 does not light, correct sensor pair 1 for a false clear condition. To fix a false clear indication for Across-the-track mode: 2. Adjust the sensor height so the train is fully blocking the light path from the IR LED to the its receiver. To fix a false clear indication for Reflective mode: 2. Adjust the sensors higher or lower in the roadbed. 3. A bright light source above and to the side of the track may be saturating the IR receiver. Try pulling it deeper into the roadbed or create shade with scenery or a structure. Or change the nearby light to a fluorescent or LED bulb. Test with several types of rolling stock and adjust the sensors as needed. Remove the train from Detector 1's detection zone, make sure LED#1 goes out. Place a train in Detector 2's detection zone. The yellow LED#2 should light. If LED#1 also turns on, adjust sensor pair 1 for false detection (see above). If LED#2 does not light, adjust sensor pair 2 for a false clear condition (same process as above for sensor pair 1). Connect sensor pair 3: Turn off the power. Move on to the next input terminal block. Connect the orange (or red) wire from the IR LED to terminal 3K. Connect the green (or blue) wire from the IR receiver to terminal 3F. Again, how you connect the two white (or yellow) wires to the MRD6X will determine whether Detector 3 will operate in 'Across the Track' or 'Reflective' mode. Connect sensor pair 4: Connect the orange (or red) wire from the IR LED to terminal 4K. Connect the green (or blue) wire from the IR receiver to terminal 4F. As with the previous sensor pairs, how you connect the two white (or yellow) wires will determine whether Detector 4 will operate in 'Across the Track' or 'Reflective' mode. Detector 4 can operate in the same mode as Detector 3, or in a different mode. When both sensor pairs are connected, there will be two white (or yellow) wires in 'X' and two white (or yellow) wires in 'R.' Turn on power to test and adjust sensor pairs 3 & 4 the same way you tested sensor pairs 1 & 2 (see pg. 2). Once sensor pairs 1-4 are working properly, connect the remaining sensors in the same way. Sensor pair 5: IR LED orange (or red) wire to 5K. IR LED white wire to X (for across-the-track) or R (for reflective mode). IR receiver green (or blue) wire to 5F. IR receiver white (or yellow) to R (across-the-track) or X (reflective). Sensor pair 6: IR LED orange (or red) wire to 6K. IR LED white wire to X (for across-the-track) or R (for reflective mode). IR receiver green (or blue) wire to 6F. IR receiver white (or yellow) to R (across-the-track) or X (reflective). Turn on power. Test and adjust sensor pairs 5 & 6. All of your sensors should now be connected and working. Output connection Terminals Q1 - Q6 and B are the output connections. C is a 'common' connection to all of the circuits on the MRD6X (the two C terminals are electrically connected). Outputs Q1 - Q6 provide a logic 'low' signal (near 0 volts) when their respective detectors are sensing an object, and provide a logic 'high' (+5 volts) when their respective detector is not sensing an object. 2015 Azatrax.com MRD6X HexDetex installation instructions pg. 3 of 5

Remote LEDs LED panel indicators or signals may be connected to the MRD6X as shown on the left. Connect the positive side of all LEDs to the '+5v' terminal of the MRD6X. Connect the negative side of each LED to its own output terminal Q1 - Q6. Separate resistors are not required, as resistors are already on the MRD6X circuit board. Solid State Relays To switch higher currents or to achieve electrical isolation between the MRD6X and the controlled circuits, use a solid state relay. The input of the solid state relay connects to the MRD6X in the same way as a remote LED. Azatrax SSR6 and Avago ASSR-1228 are examples of solid state relays that work well with the MRD6X. +5 Volt Digital Circuits The schematic at right shows an MRD6X output connected to the input of a typical digital circuit. Keep the following points in mind when choosing circuit components: Power the digital circuit with +5 volts only Use a minimum of 4.7k ohm pull up resistor, 10k is better Use CMOS logic components (4000 series or 74HC series) rather than TTL. 74LS TTL circuits usually work, but will be much more sensitive to interference. Each output Q1 - Q6 may be connected to an LED, a solid state relay or to a digital electronic circuit -- but only to one at the same time. Automating a Grade Crossing Signal The MRD6X can turn a grade crossing signal on and off when the sensors are placed as follows: 2 sensors per track, 1 or 2 tracks: Signal turns on when a train on track 1 moves from left to right and triggers sensor 1. Signal stays on as long as the train is on either sensor 1 or sensor 5. If a short train leaves sensor 1 before reaching sensor 5 the signals will stay on for up to 30 seconds. Once the train clears sensor 5, the signals will turn off. Similar operation happens if the train on track 1 moves from right to left, encountering sensor 5 first. If trains travel in both directions on a track, place the two sensors equal distances from the crossing. Sensors 2 and 6 on track 2 operate in the same way as the sensors on track 1. 4 sensors, single track: Signal turns on when a train moving left to right is detected by sensor 1. If the train does not reach sensor 3 within 30 seconds, whether it is still on sensor 1 or not, the signal will turn off. When the train does reach sensor 3, the signal remains on as long as the train is on either sensor 3 or 4. When the train clears both sensor 3 and sensor 4 the signal will turn off. Similar operation occurs when a train travels from right to left. 2015 Azatrax.com MRD6X HexDetex installation instructions pg. 4 of 5

5 or 6 sensors, 1 track: Use five or six sensors per track when trains might stop or change direction within the crossing warning zone, or when trains of vastly different speeds use the same track. Signal turns on when a train moving left to right is detected by sensor 1. The train has 30 seconds to reach sensor 2 to keep the signal on. If the train stops before it reaches sensor 2, the signal will turn off even if the train remains on sensor 1. When the train starts again and resumes its motion toward the crossing, it trips sensor 2, which will turn the signals on again. The train has another 30 seconds to reach sensor 3, or else the signals will turn off. While the train is on either sensor 3 or sensor 4 the signal will stay on. Once the train clears sensors 3 and 4 the signal will turn off. If the train is moving away from the crossing and it clears sensor 5, then stops and changes direction (now moving right to left), the signal will turn on again when the train re-triggers sensor 5. This is useful if switching moves occur near the crossing. To use just five sensors, leave either sensor 2 or sensor 5 disconnected. Connecting a Grade Crossing Signal to Output 'B' The MRD6X has a transistor to switch the low side (negative connection) of a relay or signal control / flasher circuit. Connect the relay coil or signal circuit as shown at left. Note that a DC power supply is required. This can be the same supply that powers the MRD6X (P1 & P2), or it may be a separate power supply. Up to 0.25 amp (250 milliamps), 24 volts DC may be switched through the 'B' terminal. To control one signal with multiple MRD6X's, connect the MRD6X outputs in parallel -- wire all the 'B' terminals together, and wire all the 'C' terminals together. The MRD6X can be used as an expander with Azatrax MRX1 or MRX2 crossing signal controllers to protect multiple tracks. Connect a 'C' terminal on the MRX1 or MRX2 to a 'C' terminal on each MRD6X used at the crossing. Connect the 'On' terminal of the MRX1 or MRX2 to the 'B' terminal on each MRD6X. MTH RailKing 30-11012 Crossing Gates: This O scale signal has a built-in flasher circuit and gate motor. The gates operate realistically and they are easy to install. Because the signals need power to open the gates after the train goes by, the signals cannot be directly connected to the MRD6X on/off 'B' output. A doublethrow relay (SPDT or DPDT) is needed. The diagram at right shows how to use an MRD6X and an Azatrax MRAPR relay to operate MTH 30-11012 crossing gates. RailKing is a trademark of MTH Electric Trains. 2015 Azatrax.com MRD6X HexDetex installation instructions pg. 5 of 5