SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

Similar documents
Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Design and Performance Analysis of One Ended Evacuated Tubes at Different Air Flow Rates Nitin Panwar 1

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

Effect of Inclination Angle on Temperature Characteristics of Water in- Glass Evacuated Tubes

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

To investigate the surface properties for increasing efficiency of solar water heater

Thermal Performance of a Loop Thermosyphon

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Theoretical model of circular solar collector for close water open air (CWOA) heated humidification and dehumidification

A TRNSYS Simulation Case Study on Utilization of Heat Pump For both Heating and Cooling

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Falling Film Heat Exchangers for Solar Water Heaters

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

SCIENCE & TECHNOLOGY

THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH 3 H 2 O SYSTEM

Experimental Study and Analysis of Flat Plate Solar Water Heater with Different Flow Rates using of Circulating Pump

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Operation of a Two-Phase Reverse Loop Thermosyphon

DRYING YELLOW-POPLAR IN A SOLAR-DEHUMIDIFIER KILN WITH HEAT STORAGE AND HEAT RECOVERY SYSTEMS

Recent Advances in Energy, Environment and Economic Development

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

SIMULATION OF HDH DESALINATION SYSTEM USING TILTED, TWO-PASS SOLAR AIR HEATER

DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Purdue e-pubs. Purdue University

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

Solar Still - Improved Distillation

PROCESSING OF VEGETABLES IN A SOLAR DRYER IN ARID AREAS

ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Experimental Efficiency Investigation on Heat Recovery System Used in a Solar-Powered Desalination Process

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

PRODUCING COOLING FROM SOLAR ENERGY BY USING ADSORPTION CYCLE WITH ACTIVATED CARBON AND METHANOL PAIR

Analysis of the performance profile of the NCERD thermosyphon solar water heater

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Fabrication & Performance Analysis of Solar Water Heater Using Porous Medium & Agitator

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Design and Optimization of Domestic Solar Dryer

Solar Drying Techniques And Performance Analysis: A Review

Experimental Investigation to Assess the Performance of Desiccant Integrated Chilly Dryer

Ultra Low Cost Solar Water Heater. Concept Generation and Selection Document

American International Journal of Research in Science, Technology, Engineering & Mathematics

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Development of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation

SCIENCE CHINA Technological Sciences

Key Words: Microalgae; Solar Dryer; Exergy Analysis; Energy Analysis;

Solar water heaters proposed for the British University in Egypt Bathrooms VS. Traditional electrical water

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Desiccant-enhanced evaporative (DEVap) cooler system introduction and its comparison with direct expansion (DX) system

Performance analysis of solar water heater in NEH region of India

LAB EQUIPMENT DETAILS

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING

Development and Testing of Hot Cold Tumbler Operating on Peltier Effect

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

Passive cooling of telecommunication outdoor cabinets for mobile base station

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Creating a Passive Solar Water Heating System

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

Development of TRNSYS Models for Predicting the Performance of Water-in-Glass Evacuated Tube Solar Water Heaters in Australia

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Flow and heat transfer in a closed loop thermosyphon Part II experiment al simulation

Study of solar-thermal collector assisted hybrid split air conditioner

Global Journal of Engineering Science and Research Management

liquid heating The density of the liquid changes as its temperature increases. This causes energy to be transferred throughout the liquid.

for room heating Guntis Ruskis Scientific advisers: Aivars Aboltins, Janis Palabinskis

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Performance Analysis of Heat Pipe using Different Screen Mesh Sizes Manikandan.K * 1, Senthilkumar.R 2,

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

NEBRASKA MODIFIED ROOF POND: 1985 SUMMER PERFORMANCE RESULTS

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

Heat Transfer in Evacuated Tubular Solar Collectors

Performance investigation of Air-conditioning system using ejector as expansion device

SCALE MODEL STUDIES ON SMOKE MOVEMENT IN INCLINED TUNNEL WITH LONGITUDINAL VENTILATION AND SMOKE BARRIERS

Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials

Experimentation of Heat Pipe Used In Nano-Fluids

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Air-Cooling Evaporators

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Transcription:

Third Southern African Solar Energy Conference 11 13 May 2015 Kruger National Park, South Africa SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES Shahmohamadi M., Shafii, M.B.and Sadrhosseini H.* *Author for correspondence Mechanical Engineering Department, Sharif University of Technology- International Campus, Kish Island, Iran, E-mail:sadr@kish.sharif.edu ABSTRACT Evacuated tubes are made from two layers of glasses. The inside glass is coated and the space between the glasses is evacuated. When sun radiations pass through the first layer and transfer heat to the inner side, since the space between them is evacuated it cannot cool down with convection or conduction. The common way of using an evacuated tube is to put an evacuated copper rod inside it to heat up and make contact with a water container to let the water boil. In the current study water is directly inside the inner evacuated tubes. Thus, the evaporation happens in these tubes and there is no need to use a water container or copper rods. Results show that when the amount of water is increased in the tubes the production raises significantly. Result for two values of volume of water in two days with acceptable similar solar radiation and ambient temperature are reported. INTRODUCTION Fresh water has a vast usage in both industry and civil areas hence supplying enough fresh water is a matter that always must be considered. In so many cases water desalination devices are reasonable choices. For example in the areas near the sea because of accessibility to sea water it is logical to desalinate this water to supply fresh water. The solar powered desalination process is one of the simplest but efficient methods specially for small capacity of fresh water production [1]. Solar energy is one of the most promising applications of renewable energies to sea water desalination [2]. In this manner enhancement of solar desalination devices are important. NOMENCLATURE l r T V x y z [⁰C] [L] Length Radius Temperature Volume Special characters ϴ [degree] Tilt angle with horizon Subscripts i m o t Inside Metal box Outside Evacuated tube Several studies have been reported on the performance of the evacuated tubes [3]. An experimental investigation by Chen et al. [4] on the long-term thermal performance of a two-phase thermosyphon solar water heater shows that the twophase closed thermosyphon gave better efficiency, followed by the single-phase thermosyphon one. These two evacuated tube collectors showed better thermal performance than the three flat plate collectors. Zambolin and Del Col [5] compared the performance of a flat plate collector and an evacuated tube collector for steady state and for daily operations. A single-glazed flat plate collector and an evacuated tube collector were installed side by side and tested at the same working conditions; the evacuated tube collector was a single-phase thermosyphon type with external compound parabolic concentrator reflectors. It was found that flat plate collector has better steady- state efficiency 142

and daily efficiency at low working temperature level. The situation is reversed when the collector temperature is on average much higher than the ambient temperature. Shariah et al. [6] carried out research on the optimized tilt angle of flat plate collector. A computational model in TRNSYS was applied to study the long-term performance of thermosyphon flat plate system. The systems simulated were located in two cities in northern and southern Jordan respectively. It was found that the optimum tilt angle is in the range of 0-20 larger than the location latitude. Tang et al. [7] investigated numerically the optimal tilt-angles of all-glass evacuated tube solar collectors. They suggested that for most areas in China with site latitude larger than 30, around 10 less than the site latitude is the optimal tilt angle. In common solar stills which are using for desalination the copper rods inside the evacuated tubes make contact with a water container to let the water boil. In the current study water has poured directly inside the inner evacuated tubes. THEORY AND PRINCIPLES The principle of vaporization of water in the system lies on the properties of evacuated tubes. Air is removed from each tube (evacuated) to eliminate heat loss by convection. Inside the glass tube, a flat or curved aluminum or copper fin is usually attached to a metal pipe [8]. However, in the current study, by removing the aluminum/copper fin and pouring water directly in the evacuated tubes we let the heat transfer directly from the inner wall of the evacuated tube to the water, and from the solar radiation. Water is heated until it reaches to its saturation temperature, then it starts boiling inside the tubes and vaporizes, vaporized water (superheated vapor) enters the condensation box to lose heat to its cold walls which are at the ambient temperature and condenses, condensed water which is fresh water is produced and will be collected through the bottom of the condenser. EXPERIMENTAL SETUP The system consists of two evacuated tubes which made an angle of 60 degree with the horizon. These two tubes are attached to a metal box where the condensation happens. The metal box is made of galvanized metal with the thickness of 2 millimeters. To enhance the heat transfer, top and sides of this metal box are covered by 20 heat sinks, 5 on each side. A sunshade prevents heating the system by sun radiation while the airflow through heat sinks enhances the condensation. Figure 1 shows the experimental setup. Figure 1 Experimental setup Figure 2 Schematic of the setup. Location of the thermocouples are shown by the symbol 143

Figure 2 shows the system and location of thermocouples schematically. In this figure dimensions of the condensation box,, length of the tubes 182 cm, and the angle of the tubes with the horizon, ⁰ are given. Tube inner radius,, is 47 mm and outer radius,, is 57 mm. Water has poured inside the tubes manually at the beginning of each day. To clarify the arrangement of heat sinks on the condensation box, it is presented in figure 3. One side of condensation box and heat sinks can be seen in this picture. Except the front side which the evacuated tubes are connected and the bottom of the box other four sides have same arrangement of heat sinks. Figure 3 Arrangement of heat sinks on condensation box RESULTS AND DISCUSSIONS To investigate the effect of water head in the evacuated tubes the system has tested for two days in row. In the first day the tubes are completely full of water which means 2.5 liters of water in each tube. On the other day tubes were containing 1.5 liter of water. Another test is performed in which the sunshade is removed to investigate the effect of shading. Water production on each day is measured every half an hour from 9 am to 5 pm and three thermocouples are installed to detect temperature at different locations. One thermocouple is installed about 5 cm of the open head of evacuated tube adjacent to the inner wall to indicate the inner wall temperature of tubes. The other thermocouple is hanging inside one of the evacuated tubes and is showing the temperature of water inside tubes. The last thermocouple is adjacent to the outer side of the metal box and is exploring the metal box wall temperature. Temperatures are measured every half an hour. Solar radiation also is measured during the days of test. Figures 4-9 present data taken in September 21 st, 23 rd, and 24 th, 2014, respectively. All temperatures are in degrees centigrade (Celsius) and produced water are the amount of water in milliliters produced in every half an hour. As it can be seen in Figure 4, in which the tubes were full of water the production is way better than Figure 7 where the tubes were half empty. Although at the latter day (Figure 8 and 9) the production and water temperature and inner wall temperature were higher, the overall production of the first day was better. That is due to some situations of the experiment because in the first day the water poured at 9 o clock and it takes a while for water temperature to raise enough. However, on the other day water had been in the tubes from the day before and so it was warmer at 9:30 in the morning when the test began. Even with such situation yet the production of the tubes with 2.5 litters was better. In all three cases the water temperature rises gradually until it reaches to around 97 degrees and after that it faces not noticeable changes. But the temperature of inner side of the tubes increases constantly except the day of half full tubes. At this day determining the temperature of water was not possible since head of water was below the thermocouple after 11:30. Total production at the day in which tubes were full was 990 milliliters while on the day with half empty tubes it was about milliliters. It shows that the production decreased about 19 percent when the water head in the tubes has decreased to half. In Figure 5 which shows the day with tubes full of water but without shading the total production is milliliters which shows not a significant change but it has to be considered that in this day the ambient temperature is lower and solar radiation is noticeably higher than the day with full tubes and sunshade. The production expected to be higher due to cooler ambient and higher radiation which is not the case and it may caused by absence of sun shade. The water production rate of all three cases rises and reaches its peak at about 12 o clock and then start to drop constantly. It is the same about the metal box wall temperature and it happens because reduction in water production rate is resulted from reduction in vapor entering rate to the metal box and so the reduction of wall temperature. 144

Figure 4 Full tubes with shading; production rate Figure 7 Half tubes with shading; temperatures Figure 5 Full tubes with shading; temperatures Figure 8 Full tubes without shading; production rate Figure 6 Half tubes with shading; production rate Figure 9 Full tubes without shading; temperatures 145

CONCLUSION Data from three days experiments show that evacuated tubes have better water production when they are full of water in comparison with the case in which they are half empty. At the beginning of the day the production of half empty tubes were better but the overall production of them is about 19 percent lower than full pipes. The temperature in the inner wall of half empty evacuated tubes were a bit higher but it seems that at the last hours of the test when the water head in the tubes drops dramatically the vaporization rate decreases. It is also the case in the day with full tubes but the production reduction at this situation is slighter. REFERENCES [1] Yamali C., Solmus I., A solar desalination system using humidification dehumidification process: experimental study and comparison with the theoretical results, Desalination 220, 8, pp. 538 551 [2] Garcia-Rodriguez L., Seawater desalination driven by renewable energies: a review, Desalination 143 (2) 103-l 13 [3] Zhaoting D., A Study of Energy Performance of Evacuated-tube Solar Water-heating Collectors, Master thesis, City University of Hong Kong, 2011 [4] Chen B., Y. Chang, W. Lee and S. Chen, Longterm thermosyphon performance of a two-phase thermosyphon solar water heater, SolarEnergy 83, 9, pp. 1048-1055. [5] Zambolin E. and Col D.D., Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions, Solar Energy 84,2010, pp. 1382-1396 [6] Shariah A., Al-Akhras M-Ali and Al-Omari I.A., Optimizing the tilt angle of solar collectors, Renewable Energy 26, 5, pp. 587-598 [7] Tang R., Gao W., Yu Y. and Chen H., Optimal tilt-angles of all-glass evacuated tube solar collectors, Energy 34, 9, pp. 1387-1395 [8] http://greenterrafirma.com/evacuated_tube_c ollector.html, October 2014 146